A programmable logic controller (PLC) is a solid state device that can be programmed to control industrial equipment and processes. It allows for easy programming changes by maintenance personnel and plant engineers. PLCs can operate in harsh industrial environments. RSLogix 5000 software is used to program Allen-Bradley PLCs like ControlLogix, CompactLogix, and FlexLogix. It uses names to represent data variables instead of memory addresses.
2. A Programmable controller is a solid state user
programmable control system with functions to
control logic, sequencing, timing, arithmetic
data manipulation and counting capabilities.
control logic, sequencing, timing, arithmetic
data manipulation and counting capabilities.
Programming changes are easy to enter by
maintenance personal and plant engineer.
Programmable control systems can survive
harsh, industrial environments.
2
ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
3. Why Choose RSLogix 5000?
Innovations
No need to point to physical memory addresses when writing code.
Use names to represent data variables.Use names to represent data variables.
RSLogix 5000 : No access to memory addresses
RSLogix 500 : Can access memory directly
Low-level language
3
ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
4. Advantages:
Used to program all Automation Logix platforms:
ControlLogixControlLogix
CompactLogix
FlexLogix
DriveLogix.
4
ANIL MAURYA ELECTRICAL &
ELECTRONICS ENGINEER
5. Devicenet variable speed drivesDevicenet variable speed drives
Ethernet wireless controlEthernet wireless control
PanelView control / monitoring of equipmentPanelView control / monitoring of equipment
5
ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
8. Compact I/O has a unique modular
rackless design, which both contributes to
system cost savings and reduces parts
inventory
Its communication bus, typically found inIts communication bus, typically found in
the I/O rack, is instead integrated into
each Compact I/O module
8
ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
10. Simple and affordable processors with broad capabilities
to address applications such as material handling, HVAC
control, assembly operations, small process control, and
SCADA applications.
Advanced instruction-set based on PLC-5 mid-size
processors.
Each SLC 5/01 processor has a DH-485 port forEach SLC 5/01 processor has a DH-485 port for
programming and processor-to-processor communication
initiated from the other node.
SLC 5/02, SLC 5/03, SLC 5/04 and SLC 5/05 processors
have communication ports that can initiate communication
(e.g., Ethernet, DH+, DH-485, or RS-232-C).
10
ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
22. Modify while running
Fine-tune an operating control system
including PID loops
Reduces development time
Troubleshooting
22
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
25. DF1 protocol is a data-link layer protocol that
combines features of subcategories D1 and F1 of ANSI
x3.28 specification.
Half-duplex protocol (master-slave communication)Half-duplex protocol (master-slave communication)
Full-duplex protocol (peer-to-peer communication)
Formal Driver Type: Serial, Client or Server
Connection type: RS-232 or RS-485 25
ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
27. PLC Replacement Programming Cable for the RSlogixPLC Replacement Programming Cable for the RSlogix
SeriesSeries
Allen Bradley:Allen Bradley: 17611761--CBLCBL--PM02PM02
CableCable
Supports RSLinx communications (DF1 or DHSupports RSLinx communications (DF1 or DH--485)485)
between SLC 5000, controllogix, and 1761 devices:between SLC 5000, controllogix, and 1761 devices:
For example:For example:
NET DNINET DNI
NET AICNET AIC
NET ENINET ENI
27
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
29. Mixing Media on a DeviceNet trunk line
Thick, Thin, and Flat (KwikLink) are 120 ohm impedance
cables
Apply the 'weakest link' theory when calculating distances
allowed.
when mixing cables, use KwikLink specs. To determinewhen mixing cables, use KwikLink specs. To determine
maximum length allowed
Return (V-) and shield should be grounded in accordance
with DNet requirements; (reference DN-6.7.2) available on
Rockwell website
Proper grounding discussed in Knowledgebase record
G21030.
29
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
30. EthernetEthernet 1761 NET ENI1761 NET ENI ControlLogixControlLogix⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
ControlLogixControlLogix 1761 NET DNI1761 NET DNI CompactLogixCompactLogix⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
CompactLogixCompactLogix 1761 NET AIC1761 NET AIC PLC 5000PLC 5000⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
30
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
31. InternetInternet DeviceNET BusDeviceNET Bus DH1 or DH485 KitDH1 or DH485 Kit⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
Using:
• RSLinx
• 1761 Interface Devices
• PM02 Cable(s)
31
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
35. 1784-PCC driver enhanced to increase browsing
performance. The node table object on the card
now determines valid nodes instead of RSLinx
browsing for them.
Support added for a new item property (I.D. is
5000). This property exists only for ControlLogix
items and will test an item to determine if it is
boolean.
35
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
36. New DeviceNet error code added for better address
parsing of parameter errors.
Specific support includes:
Date and CurrencyDate and Currency
Returning errors when values out of range
Failing the AddItems when requested data type is
invalid
36
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
42. Network through any standard RJ45 Ethernet
cable
100 Base-T Port with embedded LEDs allows100 Base-T Port with embedded LEDs allows
connection to provide easy-to-see link transmit
/ receive
42
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
43. Using the 1761 series adapters designed for the
RSlogix platform to connect the controllogix,
Compactlogix and PLC 5000 controllers allows
the ultimate in flexibility between components
and industry standard Ethernet and Devicenetand industry standard Ethernet and Devicenet
components.
43
ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER