SlideShare uma empresa Scribd logo
1 de 45
ABSTRACT


Countercurrent chromatography (CCC) is a generic term covering all forms of liquid–liquid
chromatography that use a support-free liquid stationary phase held in place by a simple
centrifugal or complex centrifugal force field. Biphasic liquid systems are used with one
liquid phase being the stationary phase and the other being the mobile phase. Although
initiated almost 30 years ago, CCC lacked reliable columns. This is changing now, and the
newly designed centrifuges appearing on the market make excellent CCC columns. This
review focuses on the advantages of a liquid stationary phase and addresses the
chromatographic theory of CCC. The main difference with classical liquid chromatography
(LC) is the variable volume of the stationary phase. There are mainly two different ways to
obtain a liquid stationary phase using centrifugal forces, the hydrostatic way and the
hydrodynamic way. These two kinds of CCC columns are described and compared. The
reported applications of CCC in analytical chemistry and comparison with other separation
and enrichment methods show that the technique can be successfully used in the analysis of
plants and other natural products, for the separation of biochemicals and pharmaceuticals,
for the separation of alkaloids from medical herbs, in food analysis, etc. On the basis of the
studies of the last two decades, recommendations are also given for the application of CCC
in trace inorganic analysis and in radio analytical chemistry.




                                                                                                 1
INTRODUCTION


Counter current chromatography is a method of multiple liquid liquid extraction technique where
separation of components’ having variable solubility in two immisible liquid is achieved

In a conventional liquid liquid extraction, 2 components example a and b are distributed between 2
immisible liquids; according to their partition coefficient still pure a and b are not present in these 2
liquids even after reaching equilibrium

In the counter current chromatography, two immisible solvents flow in an opposite direction in
multiple stages equilibrium is established and after several stages pure a’ and b can be obtained.

Chromatography may be define as a method of separating a mixture of components into individual
components through equilibrium distribution between two phases. Essentially, the technique of
chromatography is based on the differences in the rate at which the components of a mixture move
through a porous medium called stationary phase under the influence of some solvent or gas called
mobile phase




                                                                                                       2
PRINCIPLE


In counter current chromatography when 2 components’ a and b having varying affinity or partion
co-efficient, is distributed between 2 immisible solvents eg. X and Y which are allowed to flow in
opposite direction separation of pure a and b takes places in multiple stages

In the first stage when equilibrium is achieved in container 1, solvent X lighter or upper phase and
solvent Y heavier or lower phase will have both components a and b based on their distribution
coefficient ,let us say a is present more in X and b is present more in Y. the upper phase solvent x is
transferred to next container 2, with similar composition of solvents. Fresh solvents X is added to
container 1.

After achievement of equilibrium in container 2, now the upper phase will contains less of b, due to
its low solubility in X and more of a. this upper phase is then transferred to container 3 with similar
composition of solvents now, the upper layer of container 1 is then transferred to container 2 and
fresh solvent is added to container 1. The above steps are repeated till the upper layer contains pure
a in the n container, where n is the last container the lower phase solvent Y of container 1 contains
the pure component of b . The value of n depends upon various factors describe.

The number of steps required to separate a and b depends upon the difference in their distribution
coefficient when the difference between is more few steps are required. But when the difference in
distribution coefficient between a and b is less then more steps are required.




                                                                                                          3
4
ADVANTAGES OF COUNTER CURRENT CHROMATOGRAPHY


Modern CCC technology has many advantages over traditional preparative techniques:


Fast

CCC provides high throughput preparative separations.


Inexpensive

After the purchase of the machine the only running costs are that of the solvent. Furthermore,
solvent usage in CCC is significantly lower (by 10-50%) than that of other preparative
chromatography techniques, such as HPLC.


Gentle Technique

CCC is a very gentle technique in which the sample is only in contact with solvents and teflon (or
other inert material). Therefore CCC provides the least chance for sample
degradation/decomposition.


Versatile Selectivity

Separation of virtually every compound class has been demonstrated with CCC. Selectivity over a
full range of polarities is achieved through the use of appropriate CCC Solvent Systems.


Scaleable

CCC is able to range from milligrams to tens of grams on the same instrument. Furthermore, many
Manufacturers provide instruments that are capable of producing tons of pure product per year.
When GC or HPLC is carried out with large sample loading, resolution is lost due to issues with
surface-to-volume ratios and flow dynamics; this is avoided when both phases are liquid.




                                                                                                     5
100% Sample Recovery

Since CCC does not use a solid support, permanent adsorption of analyte onto the column is
avoided, and a 100% recovery of the analyte can be achieved in practice




       TYPES OF COUNTER CURRENT CHROMATOGRAPHY


INTRODUCTION



     LIQUID LIQUID CHROMATOGRAPHY

     SOLID LIQUID CHROMATOGRAPHY




Countercurrent chromatography (CCC) is a liquid chromatography (LC) technique that uses two
immiscible liquid phases without any solid support. As an LC technique, CCC uses many terms
already defined for chromatography [1]. This article will give the fundamentals of the CCC
technique and briefly describe the special chromatographic columns capable of maintaining a static
liquid phase using centrifugal fields. A rapid approach to selecting solvent systems that can be used
in CCC




Liquid–liquid extraction, also known as solvent extraction and partitioning, is a method to
separate compounds based on their relative solubilities in two different immiscible liquids, usually
water and an organic solvent. It is an extraction of a substance from one liquid phase into another
liquid phase. Liquid–liquid extraction is a basic technique in chemical laboratories, where it is
performed using a separatory funnel. This type of process is commonly performed after a chemical
reaction as part .




                                                                                                   6
The term partitioning is commonly used to refer to the underlying chemical and physical processes
involved in liquid–liquid extraction but may be fully synonymous. The term solvent extraction can
also refer to the separation of a substance from a mixture by preferentially dissolving that substance
in a suitable solvent. In that case, a soluble compound is separated from an insoluble compound or a
complex matrix.

Solvent extraction is used in nuclear reprocessing, ore processing, the production of fine organic
compounds, the processing of perfumes, the production of vegetable oils and biodiesel, and other
industries.

Liquid–liquid extraction is possible in non-aqueous systems: In a system consisting of a molten
metal in contact with molten salts, metals can be extracted from one phase to the other. This is
related to a mercury electrode where a metal can be reduced, the metal will often then dissolve in
the mercury to form an amalgam that modifies its electrochemistry greatly. For example, it is
possible for sodium cations to be reduced at a mercury cathode to form sodium amalgam, while at
an inert electrode (such as platinum) the sodium cations are not reduced. Instead, water is reduced to
hydrogen. A detergent or fine solid can be used to stabilize an emulsion, or third phase




Techniques


Batchwise single stage extractions

This is commonly used on the small scale in chemical labs. It is normal to use a separating funnel.
For instance, if a chemist were to extract anisole from a mixture of water and 5% acetic acid using
ether, then the anisole will enter the organic phase. The two phases would then be separated.

The acetic acid can then be scrubbed (removed) from the organic phase by shaking the organic
extract with sodium bicarbonate. The acetic acid reacts with the sodium bicarbonate to form sodium
acetate, carbon dioxide, and water.




                                                                                                    7
Multistage countercurrent continuous processes




These are commonly used in industry for the processing of metals such as the lanthanides; because
the separation factors between the lanthanides are so small many extraction stages are needed. In the
multistage processes, the aqueous raffinate from one extraction unit is fed to the next unit as the
aqueous feed, while the organic phase is moved in the opposite direction. Hence, in this way, even if
the separation between two metals in each stage is small, the overall system can have a higher
decontamination factor.

Multistage countercurrent arrays have been used for the separation of lanthanides. For the design of
a good process, the distribution ratio should be not too high (>100) or too low (<0.1) in the
extraction portion of the process. It is often the case that the process will have a section for
scrubbing unwanted metals from the organic phase, and finally a stripping section to obtain the
metal back from the organic phase.

Multistage Podbielniak contactor centrifuges produce three to five stages of theoretical extraction in
a single countercurrent pass, and are used in fermentation-based pharmaceutical and food additive
production facilities.

Centrifugal extractors mix and separate in one unit. Two liquids will be intensively mixed between
the spinning rotor and the stationary housing at speeds up to 6000 RPM. This develops great
surfaces for an ideal mass transfer from the aqueous phase into the organic phase. At 200 – 2000 g
both phases will be separated again. Centrifugal extractors minimize the solvent in the process,
optimize the product load in the solvent and extract the aqueous phase completely. Counter current
and cross current extractions are easily established.

                                                                                                    8
Extraction without chemical change




Some solutes such as noble gases can be extracted from one phase to another without the need for a
chemical reaction . This is the simplest type of solvent extraction. When a solvent is extracted, two
immiscible liquids are shaken together. The more polar solutes dissolve preferentially in the more
polar solvent, and the less polar solutes in the less polar solvent. Some solutes that do not at first
sight appear to undergo a reaction during the extraction process do not have distribution ratio that is
independent of concentration. A classic example is the extraction of carboxylic acids into non polar
media such as benzene. Here, it is often the case that the carboxylic acid will form a dimer in the
organic layer so the distribution ratio will change as a function of the acid concentration (measured
in either phase).




Solvation Mechanism


Using solvent extraction it is possible to extract uranium, plutonium, or thorium from acid solutions.
One solvent used for this purpose is the organophosphate tri-n-butyl phosphate. The PUREX
process that is commonly used in nuclear reprocessing uses a mixture of tri-n-butyl phosphate and
an inert hydrocarbon (kerosene), the uranium(VI) are extracted from strong nitric acid and are back-
extracted   (stripped)   using   weak    nitric   acid.   An   organic   soluble   uranium    complex
[UO2(TBP)2(NO3)2] is formed, then the organic layer bearing the uranium is brought into contact
with a dilute nitric acid solution; the equilibrium is shifted away from the organic soluble uranium
complex and towards the free TBP and uranyl nitrate in dilute nitric acid. The plutonium(IV) forms
a similar complex to the uranium(VI), but it is possible to strip the plutonium in more than one way;
a reducing agent that converts the plutonium to the trivalent oxidation state can be added.




                                                                                                     9
This oxidation state does not form a stable complex with TBP and nitrate unless the nitrate
concentration is very high (circa 10 mol/L nitrate is required in the aqueous phase). Another method
is to simply use dilute nitric acid as a stripping agent for the plutonium. This PUREX chemistry is a
classic example of a solvation extraction




General Procedure for Experiments on a Centrifugal LLC Instrument



Performing an LLC experiment on a centrifugal instrument usually follows most of the steps

outlined below:


1. Find a suitable solvent system The HEMWat system is well tried and tested and proves adequate

for most separations


2. Perform partition studies with different steps in the HEMWat series, with and without, acidic or

basic modifiers if there are ionisable species present in the sample to be purified. Determine

partition coefficient/distribution ratio (D and 1/D) for phases, examine the D and 1/D values to

ascertain whether resolution is feasible. D ≥ 0.5 usually produces a satisfactory separation


3. The results of step 2 show whether the experiment should be performed in NP or RP mode. D ≈ 1

i.e. in the range of approximately 0.5 – 2.5 (the sweetspot), for a component of interest is desirable




NP mode: the more polar phase is designated as SP. For the HEMWat series this is always the lower

phase


4. Prepare the solvent mixture chosen for the separation and separate the phases


5. Perform scouting experiments and refine the experimental conditions or preparative runs as
described in steps 6 - 9

                                                                                                     10
6. Set up the instrument with respect to the choice for SP and fill the column with the chosen SP at
the highest usable flow rate

7. Equilibrate the column with MP at the chosen elution flow rate. This step will displace some
quantity of SP and from the displaced volume and the system and column volumes the initial SP
retention can be calculated. These data allow prediction of elution volumes and times for the
components of interest

8. Dissolve the appropriate quantity in a volume, equal to or less than 5 – 10% of the column
volume, of either phase or preferably a mixture of the phases

9. Inject the sample, perform the elution, collect fractions and analyze then work up the required
fractions

Control of CCC selectivity is effected when using a stepped polarity solvent combination series
such as Solvent combinations in the series are formed by mixing hexane or heptanes, ethyl acetate,
methanol and water in different proportions to produce biphasic mixtures. The figure shows how
retention and selectivity change as the test mixture.




Benefits of using LLC



     No expensive, fragile solid phase used and a ‘fresh’ column for every experiment.
     Does not require dedication of particular columns to particular separations to avoid the risks
        of cross-contamination

     As long as a chosen solvent combination forms two, readily separable, approximately equal
        volume layers there are few restrictions on solvent and additive choices

                                                                                                  11
 When compared with the widely used high performance technique of RP-SLC, solute
      capacities are high

    The technique is readily scalable from mg directly to kg separations without the attendant
      problems often encountered when scaling up SLC separations

    Tolerant of viscous and particulate-containing samples and require little or no sample
      preparation.

    Separations of ‘dirty’ matrices do not usually require pre-chromatography prior to the high
      resolution step

    Experiments can usually be run in NP so that fractions are collected in essentially organic
      solvent solution and so are easily worked up

    There are no unpredictable and/or difficult to control, secondary chromatographic
      interactions to interfere with good resolution.




Applications


                                                                                             12
•   DNA purification: The ability to purify DNA from a sample is important for many modern
       biotechnology processes. However, samples often contain nucleases that degrade the target
       DNA before it can be purified. It has been shown that DNA fragments will partition into the
       light phase of a polymer–salt separation system. If ligands known to bind and deactivate
       nucleases are incorporated into the polymer phase, the nucleases will then partition into the
       heavy phase and be deactivated. Thus, this polymer–salt system is a useful tool for purifying
       DNA from a sample while simultaneously protecting it from nucleases.

   •   Food Industry: The PEG–NaCl system has been shown to be effective at partitioning small
       molecules, such as peptides and nucleic acids. These compounds are often flavorants or
       odorants. The system could then be used by the food industry to isolate or eliminate
       particular flavors


Liquid-Solid Chromatography (LSC)

This type of chromatographic technique is also called adsorption chromatography since the
mechanism of separation depends on adsorption of solutes on the stationary phase. The stationary
phase is a solid which is usually silica or alumina with the former being most widely used. The
retention times of some compound categories are as follows:Carboxylic acids > amides > amines ~
alcohols > ketones ~ aldehydes ~ esters >nitrocompounds > halides > hydrocarbons.


Mobile Phase Selection




The only factor that is used to optimize α and k’ is the mobile phase composition since the
stationary phase is a solid. Great variations in α and k’ can be obtained by variations in nature and
composition of the mobile phase. The polarity index of solvents can be used as a guide for
estimating the polarity index of the mobile phase. However, a better scale is optimally dependent
upon the adsorption energy per unit area of the solvent which is called the eluent strength, εo. The
values of the eluentstrength are related to the polarity index.


In selecting a mobile phase, two miscible solvents are used one with high eluent strength while the
other with low eluent strength. k’ is then optimized by variation of the volume ratio of the two
solvents. A small increase in εo value will significantly change k’. Therefore, large variations in k’
are possible by variation in mobile phase
                                                                                                   13
Composition.




In case of getting overlapping peaks but acceptable k’, the type of mobile phase constituents must
be changed in order to change α. It is usually possible to carry a thin layer chromatographic
separation to optimize the mobile phase composition with regards to both eluent strength and
composition




Applications of Adsorption Chromatography




LSC is best suited for the separation of non polar compounds with molecular weights below 5000.
Solutes must be soluble in non polar solvents and should have a limited solubility in aqueous
solvents. It should be remembered that the mobile phase in LSC should be non polar modified with
a polar solvent. However, the solvent polarity must not be very large since irreversible adsorption
on the stationary phase can occur precluding the use of LSC. Therefore, water is usually excluded
from mobile phases to be used in LSC. Separations of difficult to separate isomers were possible
with LSC.


Ion-Exchange Chromatography (IEC or IC

Separation of ionic species is efficiently done using ion-exchange chromatography (IEC) or simply
ion chromatography (IC). Anions can be separated on an anionic exchange resin while cations can
be separated on a cationic exchange resin.


Separation of ionic species is efficiently done using ion-exchange chromatography (IEC) or simply
ion chromatography (IC). Anions can be separated on an anionic exchange resin while cat ions can
be separated on a cationic exchange resin.


Ion-Exchange Resins and Equilibria

Cationic exchange resins are mainly of two types:



                                                                                                14
a. Sulfonic acid group like ~SO3 H+

b. Carboxylic acid group, ~COOH+

Anionic exchange resins are mainly of the tertiary amine type, ~(CH3)3N+ OH The cationic
exchange equilibria can be represented by the equation

n RSO3 - H+ (solid) + Mn+ = (RSO3 -)n Mn+ (solid) + n H+ For singly charged cations like B+,
we may write:RSO3- H+(s) + B+(aq) = RSO3

- B+(s) + H+ (aq) kex = [RSO3


Ion-Exchange Resins and Equilibria

Cationic exchange resins are mainly of two types:

a. Sulfonic acid group like ~SO3H

b. Carboxylic acid group, ~COO-H+

Anionic exchange resins are mainly of the tertiary amine type, ~(CH3)3N+ OH Thecationic

exchange equilibria can be represented by the equation:


n RSO3- H+ (solid) + Mn+ = (RSO3-)n Mn+ (solid) + n H+

For singly charged cations like B+, we may write:

RSO3 H+ (s) + B+(aq) = RSO3- B+(s) + H+ (aq) kex = [RSO3- B+]s[H+]aq/[ RSO3 - H+]s[B+]aq

- B+]s[H+]aq/[ RSO3 - H+]s[B+]aq




Ion-Exchange Resins and Equilibria

Cationic exchange resins are mainly of two types:

a. Sulfonic acid group like ~SO3 H+


                                                                                          15
b. Carboxylic acid group, ~COOH+

Anionic exchange resins are mainly of the tertiary amine type, ~(CH3)3N+ OH The cationic
exchange equilibria can be represented by the equation:

n RSO3- H+ (solid) + Mn+ = (RSO3-)n Mn+ (solid) + n H+

For singly charged cations like B+, we may write:

RSO3- H+(s) + B+(aq) = RSO3- B+(s) + H+ (aq)

kex = [RSO3- B+]s[H+]aq/[ RSO3- H+]s[B+]aq

kex = [RSO3- B+]s[H+]aq/[ RSO3- H+]s[B+]aq
K = Cs/CM = [RSO3- B+]s/[B+]aq
Where, K is the distribution constant. Therefore, kex represents the affinity of the resin RSO3 - H+
to cation B+ relative to cation H+. The affinity or kex is different for different ions and will depend
on size and charge of ions .The anionic exchange equilibria can be represented by the equation:
n R(CH3)nN+ OH- (solid) + An- = (R(CH3)nN+)n An- (solid) + n OH.




Eluent Suppressor Columns



Unfortunately, detectors available for use with IC are rather limited. Conductivity detectors are most
common where simply ions will increase the conductivity. A major drawback to using conductivity
detectors is the high salt concentration in the mobile phase which may make it very difficult to
determine differences in conductivity, especially at low solute concentrations. The problem of high
salt content of the mobile phase was solved by the use of what is called suppressor columns. The
suppressor column is packed with a second ion exchange resin that converts the ions in the
mobile phase to molecular species of limited ionization. For example, for the separation of cations,
HCl is used as the eluent and the suppressor column in this case is packed with a hydroxide anion
exchange packing. The following equilibrium takes place in the suppressor column:




                                                                                                    16
H+aq + Claq+ Resin+ OH- (solid) = Resin+ Cl- (solid) + H2O For separations of anions, the
suppressor column contains a hydrogen ion cationic exchange resin and the eluent is a
carbonate/bicarbonate mobile phase. The following equilibrium takes place: Na+aq + HCO3-aq +
Resin- H+ (solid) = Resin+ Na+ (solid) + H2CO3 (aqueous) H2CO3 (aqueous) is a weak electrolyte
which will contribute very little to conductivity. Therefore, in both cases the conductivity of the
mobile phase was eliminated using suppressor .Parameter Effect on retention in anion IC




The Mobile Phase




The mobile phase transports the sample through the system and affects both retention and selectivity
of the separation. The mobile phase is usually a solution of a salt in water, which works as a buffer,
providing a stable pH. Several considerations govern the choice of a mobile phase. The first factor is
the kind of sample ions that will be separated, but the type of separation column is also important.
For catinic separations, HCl is a most common mobile phase while the two most common mobile
phases for anionic separations are based on hydroxide or carbonate as eluting anion. In carbonate
based mobile phases, the eluent is an aqueous solution of carbonate and hydrogen carbonate salts,
where the ionic strength of the mobile phase and the ratio of the bicarbonate/carbonate ions can be
varied to optimize the retention time and selectivity. The elution strength of the mobile phase and, to
some extent, its selectivity, are affected by the type of ions of the eluent. A change of salts will
normally result in a change of the eluent pHcolumns of suitable packing.




Ionic strength


                                                                                                      17
The eluting ability of a mobile phase will increase as the ionic strength of the mobile phase is
increased. However, the change in the selectivity among equally charged ions is very small, whereas
the selectivity between ions of different charges (mono- or polyvalent) is far more sensitive to
changes in ionic strength.




PH



The charge of the sample ions of weak acids or bases are controlled by the eluent pH and thus the
retention times of such species will be affected by changes in Ph




Temperature



The ion exchange rate between the stationary and the mobile phase increases with increasing
temperature. The viscosity of the eluent, and thereby the column backpressure, decreases and can
give a better separation efficiency. The temperature can also affect the column selectivity.




Isocratic and Gradient Elution



The most common type of elution in IC is isocratic where the mobile phase has a constant
composition during the entire run. Gradient elution where the eluent concentration is changed
during the run can also be used. Gradient elution is effective when sample contains ions with widely
different retention times. Hydroxide eluents are usually used for gradient elution in anion
chromatography. By gradually increasing the concentration of hydroxide ions, the eluting power of
the mobile phase increases. As a result, ions with high retention stay at the top of the column They



                                                                                                 18
then elute in sequence as sharp peaks. After each gradient run the column must be regenerated by
pumping initial mobile phase for say 10-20 min (reproducibly getting the same baseline.



COUNTER CURRENT CHROMATOGRAPHY COLUMS:


From numerous column designs used to retain a liquid stationary phase [5–9], only two have had the
potential for sustained commercial development. They are called the hydrostatic and the
hydrodynamic configurations.




Hydrostatic CCC columns:
The very first hydrostatic CCC columns used gravity to maintain the liquid stationary phase; they
were called droplet CCC (DCCC) columns. They needed very long elution times .The columns are
no longer in use today. Modern hydrostatic CCC columns are known and marketed under the name
of centrifugal partition chromatographs Their two main characteristics are: they have a single axis
of rotation generating a constant centrifugal field and they enclose geometrical volumes, tubes,
channels, or locules that repeat themselves through connecting tubes forming a pattern .It can be
seen that there is quite a significant volume of connecting ducts which only contain the mobile
phase.




                                                                                                19
The liquid motion in CCC columns. A – Hydrostatic olumns or CPCs. There are a single axis of
rotation producing constant centrifugal field and no phase exchanges in the connecting ducts. B –
Hydrodynamic columns. There are a variable and cyclic centrifugal field produced by the planetary
rotation of the bobbin around its own axis and the central rotor axis. There is contact between the
two liquid phases throughout the tubing. The mobile phase is pictured in black, the stationary phase
is white.

                This design reduces the contact time for solute exchange with the stationary phase. It
also builds a small hydrostatic pressure that explains the significant pressure drop needed to operate
hydrostatic centrifuges. All hydrostatic centrifuges contain two rotary seals; one at the top and the
other one at the bottom. They are quiet to operate.

In the toroidal coil CCC (helix CCC) system operated under a centrifugal force, the dimensions of
the coil are reduced to that which is convenient for analytical separations. The coil is mounted
around the periphery of the centrifugal bowl so that the stable radially acting centrifugal force field
retains the stationary phase in one side of the coil as in the basic hydrostatic system described
above.



Hydrodynamic columns:


Hydrodynamic Counter current Chromatography columns


Hydrodynamic centrifuges used in the CCC columns have two rotational axes, a main axis and a
planetar one which generates a variable centrifugal force field. There can be any number of
planetary axes but the most common are single, double, and triple axes. Each planetary axis has a
bobbin or spool mounted on it that contains the coils of continuously wound Teflon tubing In
hydrodynamic columns, it is important to know the ratio of the spool radius, r, over the rotor radius,
R. This ratio was traditionally termed is defined in LC as the phase ratio.




                                                                                                    20
The tubing can be connected from the outside of the centrifuge, wound round the bobbins, and
passed back to the outside again without any rotary seals—hence, from the chromatography point of
view it is equivalent to one long thin continuous column. The variable force field produces mixing
and settling zones throughout the whole length of the coiled column as indicated in Fig. 2B. There is
continuous contact between the two liquid phases throughout the column with no significant
pressure buildup. Hydrodynamic centrifuges work with low mobile-phase pressure but can generate
noise from the gear assembly, which can be reduced in well-designed centrifuges. These columns
are often called highspeed CCC (HSCCC) columns since they can operate much more rapidly than
the Craig, DCCC, and gravity-based columns. Table 1 compares the features of the two kinds of
CCC columns. It is not possible to say that one kind is clearly superior to the other. The best
situation is to have both kinds of CCC column to cover all possible cases. Studies are going on to
develop large-scale CCC centrifuges based on both types being able to produce significant mass of
purified material (preparative CCC) [13–15]. Such centrifuges can be used to produce standard
reference materials for analytical purposes and to purify analytical reagent




                                 INSTRUMENTATION:


force of 1g (the earth’s gravity) which was not very effective at stabilising the SP. Furthermore, the
scope was limited since only the more dense phase could be used as the SP. Apart from these issues
runs could take many days even with the later, mechanized and automated versions.




                                                                                                   21
The time required to perform experiments could run into days but the instruments were capable of
resolving very complex mixtures. The technique was recognised to be gentle and offered high
resolution and enjoyed favour as the purification method of choice for high value products such as
Chinese medicines and other natural products with many groups of chromatographers. The
methodology became, and until recent years remained, a niche application and was a technique very
rarely employed by medicinal chemists.

The other significant 1g instrument was the Droplet Countercurrent Chromatograph, DCCC, which
was invented by Ito (see below) and his group in 1970. These instruments also relied on the earth’s
gravity alone to stabilise the stationary phase whilst MP was pumped through the instrument but
like the Craig machines, SP retention (stabilisation) was poor even at very low flow rates and
experiments could take days to complete. However, these instruments were able to use either phase
as SP although a significant disadvantage of these instruments was that phase mixing, an essential
pre-requisite of successful LLC, was poor.




DESCRIPTION OF CRAIG’S TECHNIQUE



A schematic representation of five stagcs in the Craig s technique of counter cirrent extraction. The
process of separation is carried cut by extracting a solution ofthc sample under test with an
immiscible solvent. According to Craig, thi step is called ‘transfer’(n 0) and is shown i.n

the top row of the figure. The vessel in which the initial extraction is allowed to take place, has been
labelled ‘tube zero’ (r= 0). The figure.also indicates four other additional vessels labelled tubes. 12,3

                                                                                                      22
and 4. These vessels are a part of a very large numbe of identical containers. All of these vessels
contain




organic solvent a mobilc one and assuming for convenience that the weight Of solute is 1000 mg.
and its partition ratio between the solvents is 1.00. It is also assumed that the volume of the organic
solvent is identical to that of aqueous phase. Thus when equilibrium is achieved-in tube 0 after
transfer, 0.500 mg. of solute will be found in each phase.

• The next step in the process (transfer no.1.) involves transfer of the organic solvent from tube 0 to
tube 1. This is also followed by an identical amount of fresh organic solvent into tube 0. When both
vessels are shaken, the solute will be distributed among the four solutions as indicated inline n=1 of
the figure 3. This process of transfer and equilibrium is epeated with an identical vôlume of fresh
organic solvent being added to tube 0 at each transfer. The distribution of solute after four transfers
(n 4) has been depictcd in line 4, where it will be seen that solute has become dist’ributed among all
tubes. Figure 4 indicates the movementof the so,lute for a much large number of transfers, when the
fraction of total solute contained in the two layers of each tube (i.e., organic portion + aqueous
portion) is plotted agailist the tube number. It has- been found thatthe distribution curves become
broader’ and lower, with an increased number of transfers. It should also be noted that for a solute
with partition ratio larger than unity, the movement will be enhanced.




                                                                                                    23
DERIVATION OF DISTRIBUTION CURRENT

The partition ratio data may be made use of in deriving the distribution curves, such as those slown
in fig. 4. Suppose fn.r be the fraction of the initial solute A present in tube r after n transfers have
been performed. Thus the sum of th total fractions must be equal to unity. That is,

f.o+ fn + f2+ f3t .. 1

We know that the partition ratio in all tubes is given by,C-

where - Cm= Concenratinof solute in the mobile phase.

C5 = Concentration of solute in stationary phase.

If now x is designated as the fraction of’öute found in the mobile organic phase of any tube and y as
the fraction found in thetationary aqueoupiase, then x+ y= 1

In any particular tube, the amount of solute found in eaëh phase is given by, weight in mobile
organic phase Cm . Vm.

weight in stationary aqueous phase = C. V5 ‘ -V ri’ iho volumes of the two phases in millilitres ahd
C, and C are expressed in grams per znillilitres. Thus,



                                                                                                     24
and




Substitution of equation (i) and rearrangement gives,




It may be made Dlear by taking the following examples. I. For n = 0. At this stage the solute is
found in tube 0 only. Thus,




fo,o X+ y 1.00

since x and y are dependent only on K’ when the volumes are fixed.

POSITION WHEN LESS DENSE

LIQUID IS RECEIVED FROM

PRECEDING TUBE AND

DURING EQUILIBRATION




                                                                                             25
(a) For r= 1. The solute in tube I comes.from the tranfer of the organic phase in tube 0, transfer 0,
which contaiiied the fraction of the original solute. Hence.

Now the transferred sDlute undergoes partition in tube 1. .A fraction x of the solute will remain in
the organic layer and a fraction y will go into the aqueous layer. Since the values of x and y are
same throughout we have




(b) For r = 0. The solute present in tube 0 comes from the aqueous layer that ontains the fraction y
of the original. Thus,



                                                                                                  26
(3) For n =2. Here, the distribution of solut occurs among tubes 0,1 and 2.

(a) For r =2. The solute in tube 2 comes from the organic layer of tube 1, transfer I containing the
fraction x2 of the original sample.




• This fraction will be again distributed to give x2 of the organic layer and x2y in the aqueous layer

of tube 2. •




                                                                                                     27
Solution— From(8) and (9), we have




Putting n= 5, and 3 -

r in equation (iv)




                                     28
APPLICATIONS OF CRAIG’S TECHNIQUE



Craig’s technique has widely been dsed particularly in the field of biochemical’s. Many closely
related compounds have been separated by making use of this technique. Craig himself had resolved
a mixture of 10 amino acids, despite the fact that the partition ratio for some of these compounds
differed by less than ?. 1. Complex mixtures of fatty acids, polypeptides nucleotides, aromatic
amines, antibiotics and many other organic substances have been fully separated by. using counter
current extraction.




TECHNIQUES:




Techniques



CCC can be thought of as occurring in three stages: mixing, settling, and separation (although they
often occur continuously). Mixing of the phases is necessary so that the interface between them has
a large area, and the analyte can move between the phases according to its partition coefficient.

A partition coefficient is a ratio of the amount of analyte found in each of the solvents at equilibrium
and is related to the analyte's affinity for one over the other. The mobile phase is mixing with then
settling from the stationary phase throughout the column. The degree of stationary phase retention
(inversely proportional to the amount of stationary phase loss or "bleed" in the course of a
separation) is a crucial parameter. Higher quality instruments have greater stationary phase
retention. The settling time is a property of the solvent system and the sample matrix, both of which
greatly influence stationary phase retention.




                                                                                                     29
Droplet Countercurrent Chromatography (DCCC)




Droplet CCC is the oldest form of CCC. It uses only gravity to move the mobile phase through the
stationary phase. In descending mode, droplets of the denser mobile phase and sample are allowed
to fall through a column of the lighter stationary phase using only gravity.

If a less dense mobile phase is used it will rise through the stationary phase; this is called ascending
mode. The eluent from one column is transferred to another; the more columns that are used, the
more theoretical plates can be achieved. The disadvantage of DCCC is that flow rates are low, and
poor mixing is achieved for most binary solvent systems, which makes this technique both time-
consuming and inefficient.




High-Performance Countercurrent Chromatography (HPCCC)




The operating principle of CCC equipment requires a column consisting of a tube coiled around a
bobbin. The bobbin is rotated in a double-axis gyratory motion (a cardioid), which causes a variable
gravity (G) field to act on the column during each rotation. This motion causes the column to see

                                                                                                     30
one partitioning step per revolution and components of the sample separate in the column due to
their partitioning coefficient between the two immiscible liquid phases used.

HPCCC works in much the same way as HSCCC but with one vital difference. A seven-year R&D
process that has produced HPCCC instruments that generated 240 g, compared to the 80 g of the
HSCCC machines. This increase in g-level and larger bore of the column has enabled a tenfold
increase in through put, due to improved mobile phase flow rates and a much higher stationary
phase retention.

Countercurrent chromatography is a preparative liquid chromatography technique, however with the
advent of the higher g HPCCC instruments it is now prossible to operate instruments with sample
loadings as low as a few milligrams, whereas in the past 100s of milligrams have been necessary.

Major application areas for this technique include natural products purification and also drug
development.




High-Speed Countercurrent Chromatography (HSCCC)




The modern era of CCC began with the development by Dr. Yoichiro Ito of the planetary centrifuge
and the many possible column geometries it can support. These devices make use of a little-known
means of making non-rotating connections between the stator and the rotor of a centrifuge. (It is
beyond the scope of this discussion to describe the method of accomplishing this. Any of the several
books available on CCC .




Functionally, the high-speed CCC consists of a helical coil of inert tubing which rotates on its
planetary axis and simultaneously rotates eccentrically about another solar axis. (These axes can be
made to coincide, but the most common or type J CCC is discussed here.) The effect is to create
zones of mixing and zones of settling which progress along the helical coil at dizzying speed. This
produces a highly favorable environment for chromatography.




                                                                                                   31
There are numerous potential variants upon this instrument design. The most significant of these is
the toroidal CCC. This instrument does not employ planetary motion. In some respects it is very like
CPC, but retains the advantage of not needing rotary seals. It also employs a capillary tube instead
of the larger-diameter tubes employed in the helices of the other CCC models. This capillary
passage makes the mixing of two phases very thorough, despite the lack of shaking or other mixing
forces. This instrument provides rapid analytical-scale separations, which can nonetheless be scaled
up to either of the larger-scale CCC instruments.




Centrifugal Partition Chromatography (CPC)




Centrifugal Partition Chromatography (CPC) was invented in the eighties by the Japanese company
Sanki Engineering Ltd, whose president was the late KanichiNunogaki. CPC has been extensively
developed in France starting from the late nineties. CPC uses centrifugal force to speed separation
and achieves higher flow rates than DCCC (which relies on gravity).

The centrifugal partition chromatograph is constituted with a unique rotor (=column). This rotor
rotates on its central axis (while HSCCC column rotates on its planetary axis and simultaneously
rotates eccentrically about another solar axis). With less vibrations and noise, the CPC offers a
wider rotation speed range (from 500 to 2000 rpm) than HSCCC. That allows a better decantation
and retention for unstable biphasic system (e.g., aqueous aqueous systems or Butanol/water
systems).

Basics of CPC: The CPC rotor is constituted by the superposition of disks engraved with small cells
connected by head / tail ducts. These cells, where the chromatographic separation takes place, can
be compared to lined-up separate funnels. The rotor is filled with the stationary phase, which stays
inside the rotor thanks to the rotation speed, while the mobile phase is pumped through. CPC can be
operated in either descending or ascending mode, where the direction is relative to the force
generated by the rotor rather than gravity. According to the fast and permanent evolution of the cells
design, the efficiency and flow rate with low back pressure are improved. The CPC offers now the
direct scale up from the analytical apparatuses (few milliliters) to industrial apparatuses (some
liters) for fast batch production.


                                                                                                   32
MODES OPERATE:



Modes of Operation




   •   Reverse phase - Aqueous phase mobile - The denser phase is pumped through as the mobile

       phase.

   •   Normal phase - Organic phase mobile - The less dense phase is used as the mobile phase.


   •   Dual-Mode: The mobile and stationary phases are reversed part way through the run.


   •   Gradient Mode: The concentration of one or more components in the mobile phase is varied

       throughout the run to achieve optimal resolution across a wider range of polarities. For

       example, a methanol-water gradient may be employed using pure heptane as the stationary

       phase. This is not possible with all binary systems, due to excessive loss of stationary phase.


   •   Elution Extrusion Mode (EECCC): The mobile phase is extruded after a certain point by

       switching the phase being pumped into the system. For example, during the Elution portion

       of a separation using an EtOAcwater system running head to tail, the aqueous mobile phase

       is being pumped into the system, . In order to switch to extrusion mode, organic phase is

       pumped into the system. This can be accomplished either with a valve on the inlet of single

       pump, or ideally with an integrated system of two or three pumps, each dedicated either to a

       single phase of a binary mixture, or to an intermediate wash solvent. This also allows for

       good resolution of compounds with high mobile-phase affinities. It requires only one column

       volume of solvent and leaves the column full of fresh stationary phase.



                                                                                                    33
•    pH Zone Refining: Acidic and basic solvents are used to elute analytes .




        Achieving Resolution in Counter Current Chromomatography


Understanding how resolution is achieved in CCC is assisted by the use of the simple model of a

series of separating funnels numbered, each containing, let’s say 10ml of ethyl acetate which has

been pre-saturated with water and which will form the SP for our experiments. For our first

experiment, 10ml of water, pre-saturated with ethyl acetate and 50 parts of a solute with a D value

of , when partitioned between ethyl acetate and water, are added to the first funnel. The funnel is

stoppered, shaken and the phases allowed to settle. At this point each of the phases will contain 25

parts of the solute.      The lower aqueous phase is transferred to the second funnel and 10ml fresh

pre-saturated water are added to. Both funnels are stoppered, shaken and allowed to settle. At this

point, the phases in will each contain parts of the solute as will those in The lower aqueous phase of

is transferred to, the lower phase of is transferred to and another portion of water is added to. All

three are stoppered, shaken and allowed to settle. Each phase in will now contain parts will still

contain 25 parts in each phase and the phases in will each contain part The process of transfer lower

phases to next funnels, add fresh portion of pre-saturated water to, shake and settle are repeated. The

solute distribution profile after the fifth iteration is shown at the bottom of the Study of the figure

shows that the solute is effectively moving through the series of funnels with a Gaussian distribution

and as the solute band progresses, the maximum, single funnel concentration decreases. After

sixteen or so such iterations, the outermost funnels, are essentially devoid of solute and the solute is

distributed between funnels with the highest concentration of solute around.


The process of transfer lower phases to next funnels, add fresh portion of pre-saturated water to,

shake and settle are repeated. The solute distribution profile after the fifth iteration is shown at the

                                                                                                     34
bottom. If a total of 100 iterations are completed and the concentrations plotted as in the solute is

distributed over about 30 funnels with the maximum concentration found in funnel 50 or so as might

be experted.




Chromatographic Resolution


Chromatographic resolution, i.e. complete separation of the components of a mixture, is the ultimate

goal of a separation process. Such a process, performed on naturally occurring materials or those of

synthetic origin, may involve many steps including techniques such as extraction, crystallization,

distillation etc and may also include one or more chromatographic steps. It is these latter with which

we are concerned i.e. the complete separation of the components of a mixture by means of a

chromatographic process.


In both research and production, the most widely used, high performance (resolution)

chromatographic method is RP-HPLC. HPCCC is a high performance (high resolution) technique

and some comparison with RP-HPLC is justified.


The Snyder resolution equation, Equation 4, tells us that resolution is the product of an efficiency

term, a selectivity term and a retention term, respectively.


This means that in order to maintain a given resolution, if the value of any single term is reduced,

then the value of one or both of the others must increase to compensate for the reduction.


Retention is a critical factor in any chromatographic process and ultimately determines column

capacity.shows a representation of the relative, characteristic SP and MP volumes in a HPCCC

column compared with those in a bonded RP-HPLC column. It should be noted that although the

active MP volume in both is much the same, in an HPCCC system the SP volume is much greater


                                                                                                   35
and furthermore that the ratio of SP/MP is inverted. This factor means that the dynamic mass

capacity of the HPCCC column is much grater than that of a rp- hplc column




HPLC chromatographers have only limited scope for improving selectivity, via Path B in the since
C18 bonded phases differ little one from another and little more from, for example, a C8 bonded
phase and the range of usable solvents is extremely limited so the usual solution to the problem for
analytical chromatographers is via Path A in the figure, i.e. moving to a higher efficiency, smaller
particle, packing. However, this is not a practicable proposition for preparative scale
chromatographers since (large volume preparative columns filled with small particle media would
be prohibitively expensive) and in any case there are currently no commercially available
preparative scale pumps capable of pumping mobile phase through a large bed of sub-media at a
practically useful flow rate. Under such circumstances the preparative scale solid-liquid
chromatographer is stymied. An alternative solution is to find a methodology which rather than
improving efficiency can exploit controllable selectivity, i.e. a CCC methodology. Even the
relatively high, compared with other CCC methods, efficiency of HPCCC is still measured in only
hundreds of plates compared with the thousands or tens of thousands of plates found in an
equivalent sized SLC column but by exploiting the optimization of selectivity the technique is
capable of high resolution.




                                                                                                 36
APPLICATION OF COUNTER CURRENT CHROMATROGRAPHY



CCC is playing an increasingly important role in separation science. All    components in the sample

solution injected into the column can be recovered and irreversible adsorption and contamination of

samples can be virtually eliminated. A crude sample can be injected directly into the column, which

simplifies sample preparation. Now CCC is successfully used for the separation of organic and

inorganic substances from a complicated mixture.


ORGANIC SUBSTANCES;

 CCC has become a method of choice in natural products chemistry and has made possible the

separation of a number of biologically interesting natural products that are difficult or impossible to

separate by other techniques Crude extracts of plants or other organisms are often too complex for

the direct analysis by HPLC. Certain materials may irreversibly bind to the packing material or may

plug the column inlet filters, and hence reduce the column life. Those restrictions do not apply to

analytical CCC, which represents an interesting method for enrichment and separation of various

analytes. The technique is also used for the separation of bio chemicals and pharmaceuticals. CCC

is especially suitable for the separation of alkaloids from medical herbs using simple solvent

systems, for the total hormonal analysis of natural samples and for the screening of new bioactive

compounds in crude extracts and other complex samples CCC has been also suggested as an

alternative to the shake flask method to measure liquid–liquid partition coefficients as a way to

characterize the lipophilic–hydrophilic nature of a compound ,below some interesting methods are

briefly described which have been successfully used in the analysis of various samples or which can

be applied to analytical purposes without serious modification of the procedures and apparatus.



                                                                                                    37
Analysis of plant and different natural products Different types of hydrodynamic (HSCCC, cross-

axis coil) and hydrostatic (toroidal coil) centrifuges can be used for separation and concentration of

various compounds from plant and different natural products. The quantity of separated compounds

may range from trace to gram amounts.




 Toroidal coil Centrifuges

Toroidal coil centrifuges have been successfully applied to the separation and purification of plant

hormones,namely, indole auxins, gibberellins, cytokinins, and abscisic acid. Indole auxins were

separatedby either hexane-ethyl acetate–methanol–water (volume ratio 0.6:1.4:1.0:1.0) or

chloroform–acetic- acid–water (2:2:1) in a column with a total capacity of 18 mL. The latter solvent

system was especially useful for the separation of abscisic acid from indole-3-acetic acid.

Gibberellins (GA3, GA4, and GA7)were separated from each other in ether-methanol-phosphate

buffer (pH 7) (3:1:2). The CCC method was suitable for the separation of four cytokinins in ethyl

acetate-methanol-phosphate buffer (pH 7)(3:1:3) [2,4,5].A toroidal coil planet centrifuge for

analytical-scale separations was used for the purification of abscisic acid (ABA) obtained from crude

plant extracts and its determination in several plant tissues using HPLC and GC-MS [34].The results of the

isolation of 3-oxo-5-steroid isomerase (KSI) from crude E. coli lysate were published [35]. A separation was

performed on ca. 3 mg of 15N-labeled KSI using a polymer-containing system based on PEO 3350. The

present method eliminates sample loss and denaturation caused by the solid support and yields pure proteins

in both preparative and analytical separations .




                                                                                                         38
High-speed hydrodynamic centrifuges (HSCCC)


Numerous applications in the analysis and preparation of natural products by CCC have been

reported. Separation of poly phenolic natural products such as flavonoids are difficult because these

compounds tend to show “peak tailing” in RP-HPLC, as well as irreversible adsorption on silica gel.

Those difficulties do not exist in CCC and are the reason why CCC has been recognized as a most

valuable technique for the isolation of polyphenols . The flavonoids and hydroxyanthraquinones can

be easily separated by CCC with a high selectivity Zhang has published the results of the separation

of alkaloids (from Stephania tetrandra S.Moore) using n-hexane–ethyl acetate–methanol–water

systems at different volume ratios, hydroxyanthraquinones (from the rhizome of Rheum palmatum

L.) using a system of hexane–ethyl acetate–methanol–water (9:1:5:5) and flavonoids (from sea

buckthorn Hippophae rhamnoides) using a system of chloroform–methanol–water (4:3:2) by CCC;

the total capacity of the column was 43 mL, the maximum revolution speed of centrifuge was 2000

rpm By increasing the flow-rate of the mobile phase in these analytical separations, the separation

time for a crude sample mixture was shortened to within 15 min, which is quite comparable with

that of analytical HPLC. Milligram and even gram amounts of substances can be isolated by the

CCC technique.



This makes it possible to produce standard reference materials for any analytical study. For the more

efficient separation of compounds having a wide range of polarity, lower and upper phases of the

solvent system were used as the mobile phase in succession. This method achieved a complete

separation of five components present in a 1-mg sample mixture. The peak fraction of each

compound was subjected to mass spectrometric analysis for compound structure confirmation

shows the countercurrent chromatogram of five major compounds in the crude extract of rhizome of

Rheum palmatum L.

                                                                                                  39
Three peaks were eluted with the upper phase in NP mode followed by two peaks which were

eluted with the lower phase in RP mode. The results indicated that peaks were corresponding to

chrysophanol, emodin, physcion, aloe-emodin, and rhein, respectively. CCC was used for the

systematic selection and optimization of a two-phase solvent system to separate alkaloids from

Coptis chinensis Franch using a system of chloroform–methanol–HCl solution. at different volume

ratios .One separation run yielded four pure alkaloids, including palmatine, berberine, epiberberine,

and coptisine from a crude alkaloid extract. Analytical application of CCC was successfully

demonstrated for the separation of microgram quantities of flavonoids from a crude ethanol extract

of sea buckthorn in a multilayer coil with a total capacity of 8 mL using a two-phase solvent system

composed of chloroform–methanol–water (4:3:2) [43]. Five peaks, including isorhamnetin and

quercetin, were well resolved and eluted within 8 min. An artificial mixture of three common plant

coumarins (herniarin, scopoletin, and umbelliferone) and one flavanone (hisperetin) was separated




                                                                                                  40
with a hydrodynamic CCC column connected to a photodiode array detector. The lower phase of a




chloroform–methanol–water.




CONCLUSION:


                                                                                           41
High Speed Counter Current Chromatography is a very good preparative separation technique. The
use of support-free liquid stationary phase and no sample loss, with high separation efficiency and
resolution by using the centrifugal field, are the characteristics that make it superior to all other
separation techniques. As there is no solid support, it is free from adsorption of solutes to the
column and the recovery of samples and reagents is without contamination or decomposition.
Another advantage is that it is possible to use the same column repeatedly for separations, with
different stationary phases. The use of HSCCC in drug discovery and product development where
there is ease of scale-up from milligrams to grams and then to kilograms, makes it an excellent
technique for the separation of natural pigments and other bioactive constituents, which are present
in minute quantities.HPCCC is an orthogonal and complementary chromatography technique to
HPLC in the armamentarium available to separation scientists and worthy of a place in the
chromatographer’s toolbox. Neither HPCCC, nor any other modern LLC methodology, is a ‘magic
bullet’ solution but with controllable, tunable selectivity it is able to very effectively tackle
problems that are difficult or totally intractable when HPLC is used. In many instances the use of
selectivity instead of efficiency can prove to be the optimal way of separating components,
especially from whenever preparative quantities require purification. More and more
chromatographers are realizing the real benefits that accrue from the use of LLC. The list of
applications of LLC grows day by day




REFERENCES


                                                                                                  42
1. Dr.S. Ravi shankar

2. B.K.sharma

3. Sikdar, Cole, et al. Aqueous Two-Phase Extractions in Bioseparations: An Assessment.
   Biotechnology 9:254. 1991

4. Szlag, Giuliano. A Low-Cost Aqueous Two Phase System for Enzyme Extraction.
   Biotechnology Techniques 2:4:277. 1988

5. Dreyer, Kragl. Ionic Liquids for Aqueous Two-Phase Extraction and Stabilization of
   Enzymes. Biotechnology and Bioengineering. 99:6:1416. 2008

6. Boland. Aqueous Two-Phase Systems: Methods and Protocols. Pg 259-269

7. 11. A. Berthod, B. Billardello. Advances in Chromatography, Vol. 40, P. Brown, E. Grushka
   (Eds.),

8. p. 8, Marcel Dekker, New York (2000).

9. 12. A. Berthod. In Centrifugal Partition Chromatography, A. P. Foucault (Ed.),
   Chromatographic

10. Science Series, Vol. 68, p. 167, Marcel Dekker, New York (1995).

11. I. A. Sutherland, J. de Folter, P. L. Wood. J. Liq. Chromatogr. Rel. Technol. 26, 1449
   (2003).

12. P. L. Wood, D. Hawes, L. Janaway, I. A. Sutherland. J. Liq. Chromatogr. Rel. Technol. 26,
   1373

13. (2003).

14. A. Marston, K. Hostettmann. J. Chromatogr., A 658, 315 (1994).

15. Y. Ito. J. Chromatogr., A 1065

16. 11. A. Berthod, B. Billardello. Advances in Chromatography, Vol. 40, P. Brown, E. Grushka
   (Eds.),

17. p. 8, Marcel Dekker, New York (2000).



                                                                                          43
18. 12. A. Berthod. In Centrifugal Partition Chromatography, A. P. Foucault (Ed.),
   Chromatographic

19. Science Series, Vol. 68, p. 167, Marcel Dekker, New York (1995).

20. 13. I. A. Sutherland, J. de Folter, P. L. Wood. J. Liq. Chromatogr. Rel. Technol. 26, 1449
   (2003).

21. 14. P. L. Wood, D. Hawes, L. Janaway, I. A. Sutherland. J. Liq. Chromatogr. Rel. Technol.
   26, 1373(2003).

22. 15. A. Marston, K. Hostettmann. J. Chromatogr., A 658, 315 (1994).

23. 16. Y. Ito. J. Chromatogr., A 1065,,

24. . Oka. In High-Speed Countercurrent Chromatography, Y. Ito, W. D. Conway (Eds.), p. 73,
   John

25. Wiley, Chichester (1996)

26. Kanichi Nunogaki was invented centrifugal partition chromatography japans company
   engineering limited whose president

27. Coptis chinensis was invented counter current chromatography .for the development of
   applications




                                                                                           44
18. 12. A. Berthod. In Centrifugal Partition Chromatography, A. P. Foucault (Ed.),
   Chromatographic

19. Science Series, Vol. 68, p. 167, Marcel Dekker, New York (1995).

20. 13. I. A. Sutherland, J. de Folter, P. L. Wood. J. Liq. Chromatogr. Rel. Technol. 26, 1449
   (2003).

21. 14. P. L. Wood, D. Hawes, L. Janaway, I. A. Sutherland. J. Liq. Chromatogr. Rel. Technol.
   26, 1373(2003).

22. 15. A. Marston, K. Hostettmann. J. Chromatogr., A 658, 315 (1994).

23. 16. Y. Ito. J. Chromatogr., A 1065,,

24. . Oka. In High-Speed Countercurrent Chromatography, Y. Ito, W. D. Conway (Eds.), p. 73,
   John

25. Wiley, Chichester (1996)

26. Kanichi Nunogaki was invented centrifugal partition chromatography japans company
   engineering limited whose president

27. Coptis chinensis was invented counter current chromatography .for the development of
   applications




                                                                                           44

Mais conteúdo relacionado

Mais procurados

Hplc by niper pharma analysis
Hplc by niper pharma analysisHplc by niper pharma analysis
Hplc by niper pharma analysispatil17
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)SACHINKUMARVISHWAKAR4
 
Demostration of HPLC Chromatography
Demostration of HPLC ChromatographyDemostration of HPLC Chromatography
Demostration of HPLC ChromatographyShwetaYadav150
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)Tulsi Makwana
 
High performance liquid chromatography
High performance liquid chromatographyHigh performance liquid chromatography
High performance liquid chromatographySyed Shah
 
Hplc by naveed 27 nov 2018
Hplc by naveed   27 nov 2018Hplc by naveed   27 nov 2018
Hplc by naveed 27 nov 2018MNKhanji
 
New microsoft office power point presentation
New microsoft office power point presentationNew microsoft office power point presentation
New microsoft office power point presentationHARSHITHA REDDY
 
ultra performance liquid chromatography ppt.by Manoj Ingale
ultra performance liquid chromatography ppt.by Manoj Ingaleultra performance liquid chromatography ppt.by Manoj Ingale
ultra performance liquid chromatography ppt.by Manoj IngaleIndus Biotech Pvt.Ltd.
 
HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)
HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)
HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)royal college of pharmacy
 
Flash and chiral chromatography
Flash and chiral chromatographyFlash and chiral chromatography
Flash and chiral chromatographyceutics1315
 
Hplc introduction
Hplc introductionHplc introduction
Hplc introductionPrajaktaK7
 

Mais procurados (20)

Hpcpc ppt
Hpcpc pptHpcpc ppt
Hpcpc ppt
 
Hplc by niper pharma analysis
Hplc by niper pharma analysisHplc by niper pharma analysis
Hplc by niper pharma analysis
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)
 
Demostration of HPLC Chromatography
Demostration of HPLC ChromatographyDemostration of HPLC Chromatography
Demostration of HPLC Chromatography
 
Hplc
HplcHplc
Hplc
 
Introduction to hplc
Introduction to hplcIntroduction to hplc
Introduction to hplc
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)
 
High performance liquid chromatography
High performance liquid chromatographyHigh performance liquid chromatography
High performance liquid chromatography
 
Flash chromatography
Flash chromatographyFlash chromatography
Flash chromatography
 
HPLC
HPLCHPLC
HPLC
 
Hplc by naveed 27 nov 2018
Hplc by naveed   27 nov 2018Hplc by naveed   27 nov 2018
Hplc by naveed 27 nov 2018
 
HPLC BY MANOJ KUMAR.M
HPLC BY MANOJ KUMAR.MHPLC BY MANOJ KUMAR.M
HPLC BY MANOJ KUMAR.M
 
Hplc
HplcHplc
Hplc
 
New microsoft office power point presentation
New microsoft office power point presentationNew microsoft office power point presentation
New microsoft office power point presentation
 
What is HPLC
What is HPLCWhat is HPLC
What is HPLC
 
ultra performance liquid chromatography ppt.by Manoj Ingale
ultra performance liquid chromatography ppt.by Manoj Ingaleultra performance liquid chromatography ppt.by Manoj Ingale
ultra performance liquid chromatography ppt.by Manoj Ingale
 
HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)
HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)
HPLC (HIGH PERFORMANCE LIQUID CHROMATOGRAPHY)
 
Flash and chiral chromatography
Flash and chiral chromatographyFlash and chiral chromatography
Flash and chiral chromatography
 
Hplc introduction
Hplc introductionHplc introduction
Hplc introduction
 
Hplc
HplcHplc
Hplc
 

Semelhante a Abstrct

Chromatography BY Hamunyare Ndwabe
Chromatography BY Hamunyare NdwabeChromatography BY Hamunyare Ndwabe
Chromatography BY Hamunyare NdwabeHamunyare Ndwabe
 
Chapter 6 (HPLC) rev a
Chapter 6 (HPLC) rev aChapter 6 (HPLC) rev a
Chapter 6 (HPLC) rev aSunita Jobli
 
high_performance_liquid_chromatography.pdf
high_performance_liquid_chromatography.pdfhigh_performance_liquid_chromatography.pdf
high_performance_liquid_chromatography.pdfmeriemmokhtar1
 
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdfChapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdfNeelam Malik
 
Column Chromatography - an overview _ ScienceDirect Topics.pdf
Column Chromatography - an overview _ ScienceDirect Topics.pdfColumn Chromatography - an overview _ ScienceDirect Topics.pdf
Column Chromatography - an overview _ ScienceDirect Topics.pdfPlexDon
 
High Performance Liquid Chromatography
High Performance Liquid ChromatographyHigh Performance Liquid Chromatography
High Performance Liquid ChromatographyPayal Vaswani
 
Advanced techniques and laborotory equipments for biologists
Advanced techniques and laborotory equipments for biologistsAdvanced techniques and laborotory equipments for biologists
Advanced techniques and laborotory equipments for biologistsNawfal Aldujaily
 
Chromatography( HPLC, ion exchange chromatography, Gas chromatography)
Chromatography( HPLC, ion exchange chromatography, Gas chromatography)Chromatography( HPLC, ion exchange chromatography, Gas chromatography)
Chromatography( HPLC, ion exchange chromatography, Gas chromatography)ushaSanmugaraj
 
DSE-2, ANALYTICAL METHODS -Ch-II.pptx
DSE-2, ANALYTICAL METHODS -Ch-II.pptxDSE-2, ANALYTICAL METHODS -Ch-II.pptx
DSE-2, ANALYTICAL METHODS -Ch-II.pptxMathabhanga College
 
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR HIGH PRESSURE LIQUID CHROMAT...
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR  HIGH PRESSURE LIQUID CHROMAT...HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR  HIGH PRESSURE LIQUID CHROMAT...
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR HIGH PRESSURE LIQUID CHROMAT...Dr. Ravi Sankar
 
High performance liquid chromatography
High performance liquid chromatographyHigh performance liquid chromatography
High performance liquid chromatographyAbu Sufiyan Chhipa
 
instrumental cha 4
instrumental cha 4instrumental cha 4
instrumental cha 4Ibseusso
 
instrumental cha 4.pdf
instrumental cha 4.pdfinstrumental cha 4.pdf
instrumental cha 4.pdfIbsa15
 
chromotography-140516031516-phpapp02.pdf
chromotography-140516031516-phpapp02.pdfchromotography-140516031516-phpapp02.pdf
chromotography-140516031516-phpapp02.pdfPratyushNahak
 

Semelhante a Abstrct (20)

Chromatography BY Hamunyare Ndwabe
Chromatography BY Hamunyare NdwabeChromatography BY Hamunyare Ndwabe
Chromatography BY Hamunyare Ndwabe
 
Liquid chromatography
Liquid chromatographyLiquid chromatography
Liquid chromatography
 
Chapter 6 (HPLC) rev a
Chapter 6 (HPLC) rev aChapter 6 (HPLC) rev a
Chapter 6 (HPLC) rev a
 
high_performance_liquid_chromatography.pdf
high_performance_liquid_chromatography.pdfhigh_performance_liquid_chromatography.pdf
high_performance_liquid_chromatography.pdf
 
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdfChapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
 
Column Chromatography - an overview _ ScienceDirect Topics.pdf
Column Chromatography - an overview _ ScienceDirect Topics.pdfColumn Chromatography - an overview _ ScienceDirect Topics.pdf
Column Chromatography - an overview _ ScienceDirect Topics.pdf
 
High Performance Liquid Chromatography
High Performance Liquid ChromatographyHigh Performance Liquid Chromatography
High Performance Liquid Chromatography
 
Chromatography
ChromatographyChromatography
Chromatography
 
Advanced techniques and laborotory equipments for biologists
Advanced techniques and laborotory equipments for biologistsAdvanced techniques and laborotory equipments for biologists
Advanced techniques and laborotory equipments for biologists
 
Chromatography( HPLC, ion exchange chromatography, Gas chromatography)
Chromatography( HPLC, ion exchange chromatography, Gas chromatography)Chromatography( HPLC, ion exchange chromatography, Gas chromatography)
Chromatography( HPLC, ion exchange chromatography, Gas chromatography)
 
Chromatography HPLC Shabir
Chromatography  HPLC ShabirChromatography  HPLC Shabir
Chromatography HPLC Shabir
 
DSE-2, ANALYTICAL METHODS -Ch-II.pptx
DSE-2, ANALYTICAL METHODS -Ch-II.pptxDSE-2, ANALYTICAL METHODS -Ch-II.pptx
DSE-2, ANALYTICAL METHODS -Ch-II.pptx
 
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR HIGH PRESSURE LIQUID CHROMAT...
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR  HIGH PRESSURE LIQUID CHROMAT...HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR  HIGH PRESSURE LIQUID CHROMAT...
HPLC[ HIGH PERPROMANCE LIQUID CHROMATOGRAPHY OR HIGH PRESSURE LIQUID CHROMAT...
 
High performance liquid chromatography
High performance liquid chromatographyHigh performance liquid chromatography
High performance liquid chromatography
 
HPLC.pptx
HPLC.pptxHPLC.pptx
HPLC.pptx
 
instrumental cha 4
instrumental cha 4instrumental cha 4
instrumental cha 4
 
instrumental cha 4.pdf
instrumental cha 4.pdfinstrumental cha 4.pdf
instrumental cha 4.pdf
 
Partition column-chromatography
Partition column-chromatographyPartition column-chromatography
Partition column-chromatography
 
chromatography
chromatographychromatography
chromatography
 
chromotography-140516031516-phpapp02.pdf
chromotography-140516031516-phpapp02.pdfchromotography-140516031516-phpapp02.pdf
chromotography-140516031516-phpapp02.pdf
 

Último

group_15_empirya_p1projectIndustrial.pdf
group_15_empirya_p1projectIndustrial.pdfgroup_15_empirya_p1projectIndustrial.pdf
group_15_empirya_p1projectIndustrial.pdfneelspinoy
 
Color Theory Explained for Noobs- Think360 Studio
Color Theory Explained for Noobs- Think360 StudioColor Theory Explained for Noobs- Think360 Studio
Color Theory Explained for Noobs- Think360 StudioThink360 Studio
 
10 Best WordPress Plugins to make the website effective in 2024
10 Best WordPress Plugins to make the website effective in 202410 Best WordPress Plugins to make the website effective in 2024
10 Best WordPress Plugins to make the website effective in 2024digital learning point
 
Map of St. Louis Parks
Map of St. Louis Parks                              Map of St. Louis Parks
Map of St. Louis Parks CharlottePulte
 
Making and Unmaking of Chandigarh - A City of Two Plans2-4-24.ppt
Making and Unmaking of Chandigarh - A City of Two Plans2-4-24.pptMaking and Unmaking of Chandigarh - A City of Two Plans2-4-24.ppt
Making and Unmaking of Chandigarh - A City of Two Plans2-4-24.pptJIT KUMAR GUPTA
 
world health day 2024.pptxgbbvggvbhjjjbbbb
world health day 2024.pptxgbbvggvbhjjjbbbbworld health day 2024.pptxgbbvggvbhjjjbbbb
world health day 2024.pptxgbbvggvbhjjjbbbbpreetirao780
 
Karim apartment ideas 02 ppppppppppppppp
Karim apartment ideas 02 pppppppppppppppKarim apartment ideas 02 ppppppppppppppp
Karim apartment ideas 02 pppppppppppppppNadaMohammed714321
 
Interior Design for Office a cura di RMG Project Studio
Interior Design for Office a cura di RMG Project StudioInterior Design for Office a cura di RMG Project Studio
Interior Design for Office a cura di RMG Project StudioRMG Project Studio
 
Unit1_Syllbwbnwnwneneneneneneentation_Sem2.pptx
Unit1_Syllbwbnwnwneneneneneneentation_Sem2.pptxUnit1_Syllbwbnwnwneneneneneneentation_Sem2.pptx
Unit1_Syllbwbnwnwneneneneneneentation_Sem2.pptxNitish292041
 
General Knowledge Quiz Game C++ CODE.pptx
General Knowledge Quiz Game C++ CODE.pptxGeneral Knowledge Quiz Game C++ CODE.pptx
General Knowledge Quiz Game C++ CODE.pptxmarckustrevion
 
Pearl Disrtrict urban analyusis study pptx
Pearl Disrtrict urban analyusis study pptxPearl Disrtrict urban analyusis study pptx
Pearl Disrtrict urban analyusis study pptxDanielTamiru4
 
Top 10 Modern Web Design Trends for 2025
Top 10 Modern Web Design Trends for 2025Top 10 Modern Web Design Trends for 2025
Top 10 Modern Web Design Trends for 2025Rndexperts
 
办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书
办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书
办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书zdzoqco
 
DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...
DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...
DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...Rishabh Aryan
 
Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...
Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...
Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...Associazione Digital Days
 
Karim apartment ideas 01 ppppppppppppppp
Karim apartment ideas 01 pppppppppppppppKarim apartment ideas 01 ppppppppppppppp
Karim apartment ideas 01 pppppppppppppppNadaMohammed714321
 
Piece by Piece Magazine
Piece by Piece Magazine                      Piece by Piece Magazine
Piece by Piece Magazine CharlottePulte
 
怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道
怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道
怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道yrolcks
 
guest bathroom white and blue ssssssssss
guest bathroom white and blue ssssssssssguest bathroom white and blue ssssssssss
guest bathroom white and blue ssssssssssNadaMohammed714321
 
AI and Design Vol. 2: Navigating the New Frontier - Morgenbooster
AI and Design Vol. 2: Navigating the New Frontier - MorgenboosterAI and Design Vol. 2: Navigating the New Frontier - Morgenbooster
AI and Design Vol. 2: Navigating the New Frontier - Morgenbooster1508 A/S
 

Último (20)

group_15_empirya_p1projectIndustrial.pdf
group_15_empirya_p1projectIndustrial.pdfgroup_15_empirya_p1projectIndustrial.pdf
group_15_empirya_p1projectIndustrial.pdf
 
Color Theory Explained for Noobs- Think360 Studio
Color Theory Explained for Noobs- Think360 StudioColor Theory Explained for Noobs- Think360 Studio
Color Theory Explained for Noobs- Think360 Studio
 
10 Best WordPress Plugins to make the website effective in 2024
10 Best WordPress Plugins to make the website effective in 202410 Best WordPress Plugins to make the website effective in 2024
10 Best WordPress Plugins to make the website effective in 2024
 
Map of St. Louis Parks
Map of St. Louis Parks                              Map of St. Louis Parks
Map of St. Louis Parks
 
Making and Unmaking of Chandigarh - A City of Two Plans2-4-24.ppt
Making and Unmaking of Chandigarh - A City of Two Plans2-4-24.pptMaking and Unmaking of Chandigarh - A City of Two Plans2-4-24.ppt
Making and Unmaking of Chandigarh - A City of Two Plans2-4-24.ppt
 
world health day 2024.pptxgbbvggvbhjjjbbbb
world health day 2024.pptxgbbvggvbhjjjbbbbworld health day 2024.pptxgbbvggvbhjjjbbbb
world health day 2024.pptxgbbvggvbhjjjbbbb
 
Karim apartment ideas 02 ppppppppppppppp
Karim apartment ideas 02 pppppppppppppppKarim apartment ideas 02 ppppppppppppppp
Karim apartment ideas 02 ppppppppppppppp
 
Interior Design for Office a cura di RMG Project Studio
Interior Design for Office a cura di RMG Project StudioInterior Design for Office a cura di RMG Project Studio
Interior Design for Office a cura di RMG Project Studio
 
Unit1_Syllbwbnwnwneneneneneneentation_Sem2.pptx
Unit1_Syllbwbnwnwneneneneneneentation_Sem2.pptxUnit1_Syllbwbnwnwneneneneneneentation_Sem2.pptx
Unit1_Syllbwbnwnwneneneneneneentation_Sem2.pptx
 
General Knowledge Quiz Game C++ CODE.pptx
General Knowledge Quiz Game C++ CODE.pptxGeneral Knowledge Quiz Game C++ CODE.pptx
General Knowledge Quiz Game C++ CODE.pptx
 
Pearl Disrtrict urban analyusis study pptx
Pearl Disrtrict urban analyusis study pptxPearl Disrtrict urban analyusis study pptx
Pearl Disrtrict urban analyusis study pptx
 
Top 10 Modern Web Design Trends for 2025
Top 10 Modern Web Design Trends for 2025Top 10 Modern Web Design Trends for 2025
Top 10 Modern Web Design Trends for 2025
 
办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书
办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书
办理卡尔顿大学毕业证成绩单|购买加拿大文凭证书
 
DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...
DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...
DAKSHIN BIHAR GRAMIN BANK: REDEFINING THE DIGITAL BANKING EXPERIENCE WITH A U...
 
Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...
Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...
Giulio Michelon, Founder di @Belka – “Oltre le Stime: Sviluppare una Mentalit...
 
Karim apartment ideas 01 ppppppppppppppp
Karim apartment ideas 01 pppppppppppppppKarim apartment ideas 01 ppppppppppppppp
Karim apartment ideas 01 ppppppppppppppp
 
Piece by Piece Magazine
Piece by Piece Magazine                      Piece by Piece Magazine
Piece by Piece Magazine
 
怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道
怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道
怎么办理英国Newcastle毕业证纽卡斯尔大学学位证书一手渠道
 
guest bathroom white and blue ssssssssss
guest bathroom white and blue ssssssssssguest bathroom white and blue ssssssssss
guest bathroom white and blue ssssssssss
 
AI and Design Vol. 2: Navigating the New Frontier - Morgenbooster
AI and Design Vol. 2: Navigating the New Frontier - MorgenboosterAI and Design Vol. 2: Navigating the New Frontier - Morgenbooster
AI and Design Vol. 2: Navigating the New Frontier - Morgenbooster
 

Abstrct

  • 1. ABSTRACT Countercurrent chromatography (CCC) is a generic term covering all forms of liquid–liquid chromatography that use a support-free liquid stationary phase held in place by a simple centrifugal or complex centrifugal force field. Biphasic liquid systems are used with one liquid phase being the stationary phase and the other being the mobile phase. Although initiated almost 30 years ago, CCC lacked reliable columns. This is changing now, and the newly designed centrifuges appearing on the market make excellent CCC columns. This review focuses on the advantages of a liquid stationary phase and addresses the chromatographic theory of CCC. The main difference with classical liquid chromatography (LC) is the variable volume of the stationary phase. There are mainly two different ways to obtain a liquid stationary phase using centrifugal forces, the hydrostatic way and the hydrodynamic way. These two kinds of CCC columns are described and compared. The reported applications of CCC in analytical chemistry and comparison with other separation and enrichment methods show that the technique can be successfully used in the analysis of plants and other natural products, for the separation of biochemicals and pharmaceuticals, for the separation of alkaloids from medical herbs, in food analysis, etc. On the basis of the studies of the last two decades, recommendations are also given for the application of CCC in trace inorganic analysis and in radio analytical chemistry. 1
  • 2. INTRODUCTION Counter current chromatography is a method of multiple liquid liquid extraction technique where separation of components’ having variable solubility in two immisible liquid is achieved In a conventional liquid liquid extraction, 2 components example a and b are distributed between 2 immisible liquids; according to their partition coefficient still pure a and b are not present in these 2 liquids even after reaching equilibrium In the counter current chromatography, two immisible solvents flow in an opposite direction in multiple stages equilibrium is established and after several stages pure a’ and b can be obtained. Chromatography may be define as a method of separating a mixture of components into individual components through equilibrium distribution between two phases. Essentially, the technique of chromatography is based on the differences in the rate at which the components of a mixture move through a porous medium called stationary phase under the influence of some solvent or gas called mobile phase 2
  • 3. PRINCIPLE In counter current chromatography when 2 components’ a and b having varying affinity or partion co-efficient, is distributed between 2 immisible solvents eg. X and Y which are allowed to flow in opposite direction separation of pure a and b takes places in multiple stages In the first stage when equilibrium is achieved in container 1, solvent X lighter or upper phase and solvent Y heavier or lower phase will have both components a and b based on their distribution coefficient ,let us say a is present more in X and b is present more in Y. the upper phase solvent x is transferred to next container 2, with similar composition of solvents. Fresh solvents X is added to container 1. After achievement of equilibrium in container 2, now the upper phase will contains less of b, due to its low solubility in X and more of a. this upper phase is then transferred to container 3 with similar composition of solvents now, the upper layer of container 1 is then transferred to container 2 and fresh solvent is added to container 1. The above steps are repeated till the upper layer contains pure a in the n container, where n is the last container the lower phase solvent Y of container 1 contains the pure component of b . The value of n depends upon various factors describe. The number of steps required to separate a and b depends upon the difference in their distribution coefficient when the difference between is more few steps are required. But when the difference in distribution coefficient between a and b is less then more steps are required. 3
  • 4. 4
  • 5. ADVANTAGES OF COUNTER CURRENT CHROMATOGRAPHY Modern CCC technology has many advantages over traditional preparative techniques: Fast CCC provides high throughput preparative separations. Inexpensive After the purchase of the machine the only running costs are that of the solvent. Furthermore, solvent usage in CCC is significantly lower (by 10-50%) than that of other preparative chromatography techniques, such as HPLC. Gentle Technique CCC is a very gentle technique in which the sample is only in contact with solvents and teflon (or other inert material). Therefore CCC provides the least chance for sample degradation/decomposition. Versatile Selectivity Separation of virtually every compound class has been demonstrated with CCC. Selectivity over a full range of polarities is achieved through the use of appropriate CCC Solvent Systems. Scaleable CCC is able to range from milligrams to tens of grams on the same instrument. Furthermore, many Manufacturers provide instruments that are capable of producing tons of pure product per year. When GC or HPLC is carried out with large sample loading, resolution is lost due to issues with surface-to-volume ratios and flow dynamics; this is avoided when both phases are liquid. 5
  • 6. 100% Sample Recovery Since CCC does not use a solid support, permanent adsorption of analyte onto the column is avoided, and a 100% recovery of the analyte can be achieved in practice TYPES OF COUNTER CURRENT CHROMATOGRAPHY INTRODUCTION  LIQUID LIQUID CHROMATOGRAPHY  SOLID LIQUID CHROMATOGRAPHY Countercurrent chromatography (CCC) is a liquid chromatography (LC) technique that uses two immiscible liquid phases without any solid support. As an LC technique, CCC uses many terms already defined for chromatography [1]. This article will give the fundamentals of the CCC technique and briefly describe the special chromatographic columns capable of maintaining a static liquid phase using centrifugal fields. A rapid approach to selecting solvent systems that can be used in CCC Liquid–liquid extraction, also known as solvent extraction and partitioning, is a method to separate compounds based on their relative solubilities in two different immiscible liquids, usually water and an organic solvent. It is an extraction of a substance from one liquid phase into another liquid phase. Liquid–liquid extraction is a basic technique in chemical laboratories, where it is performed using a separatory funnel. This type of process is commonly performed after a chemical reaction as part . 6
  • 7. The term partitioning is commonly used to refer to the underlying chemical and physical processes involved in liquid–liquid extraction but may be fully synonymous. The term solvent extraction can also refer to the separation of a substance from a mixture by preferentially dissolving that substance in a suitable solvent. In that case, a soluble compound is separated from an insoluble compound or a complex matrix. Solvent extraction is used in nuclear reprocessing, ore processing, the production of fine organic compounds, the processing of perfumes, the production of vegetable oils and biodiesel, and other industries. Liquid–liquid extraction is possible in non-aqueous systems: In a system consisting of a molten metal in contact with molten salts, metals can be extracted from one phase to the other. This is related to a mercury electrode where a metal can be reduced, the metal will often then dissolve in the mercury to form an amalgam that modifies its electrochemistry greatly. For example, it is possible for sodium cations to be reduced at a mercury cathode to form sodium amalgam, while at an inert electrode (such as platinum) the sodium cations are not reduced. Instead, water is reduced to hydrogen. A detergent or fine solid can be used to stabilize an emulsion, or third phase Techniques Batchwise single stage extractions This is commonly used on the small scale in chemical labs. It is normal to use a separating funnel. For instance, if a chemist were to extract anisole from a mixture of water and 5% acetic acid using ether, then the anisole will enter the organic phase. The two phases would then be separated. The acetic acid can then be scrubbed (removed) from the organic phase by shaking the organic extract with sodium bicarbonate. The acetic acid reacts with the sodium bicarbonate to form sodium acetate, carbon dioxide, and water. 7
  • 8. Multistage countercurrent continuous processes These are commonly used in industry for the processing of metals such as the lanthanides; because the separation factors between the lanthanides are so small many extraction stages are needed. In the multistage processes, the aqueous raffinate from one extraction unit is fed to the next unit as the aqueous feed, while the organic phase is moved in the opposite direction. Hence, in this way, even if the separation between two metals in each stage is small, the overall system can have a higher decontamination factor. Multistage countercurrent arrays have been used for the separation of lanthanides. For the design of a good process, the distribution ratio should be not too high (>100) or too low (<0.1) in the extraction portion of the process. It is often the case that the process will have a section for scrubbing unwanted metals from the organic phase, and finally a stripping section to obtain the metal back from the organic phase. Multistage Podbielniak contactor centrifuges produce three to five stages of theoretical extraction in a single countercurrent pass, and are used in fermentation-based pharmaceutical and food additive production facilities. Centrifugal extractors mix and separate in one unit. Two liquids will be intensively mixed between the spinning rotor and the stationary housing at speeds up to 6000 RPM. This develops great surfaces for an ideal mass transfer from the aqueous phase into the organic phase. At 200 – 2000 g both phases will be separated again. Centrifugal extractors minimize the solvent in the process, optimize the product load in the solvent and extract the aqueous phase completely. Counter current and cross current extractions are easily established. 8
  • 9. Extraction without chemical change Some solutes such as noble gases can be extracted from one phase to another without the need for a chemical reaction . This is the simplest type of solvent extraction. When a solvent is extracted, two immiscible liquids are shaken together. The more polar solutes dissolve preferentially in the more polar solvent, and the less polar solutes in the less polar solvent. Some solutes that do not at first sight appear to undergo a reaction during the extraction process do not have distribution ratio that is independent of concentration. A classic example is the extraction of carboxylic acids into non polar media such as benzene. Here, it is often the case that the carboxylic acid will form a dimer in the organic layer so the distribution ratio will change as a function of the acid concentration (measured in either phase). Solvation Mechanism Using solvent extraction it is possible to extract uranium, plutonium, or thorium from acid solutions. One solvent used for this purpose is the organophosphate tri-n-butyl phosphate. The PUREX process that is commonly used in nuclear reprocessing uses a mixture of tri-n-butyl phosphate and an inert hydrocarbon (kerosene), the uranium(VI) are extracted from strong nitric acid and are back- extracted (stripped) using weak nitric acid. An organic soluble uranium complex [UO2(TBP)2(NO3)2] is formed, then the organic layer bearing the uranium is brought into contact with a dilute nitric acid solution; the equilibrium is shifted away from the organic soluble uranium complex and towards the free TBP and uranyl nitrate in dilute nitric acid. The plutonium(IV) forms a similar complex to the uranium(VI), but it is possible to strip the plutonium in more than one way; a reducing agent that converts the plutonium to the trivalent oxidation state can be added. 9
  • 10. This oxidation state does not form a stable complex with TBP and nitrate unless the nitrate concentration is very high (circa 10 mol/L nitrate is required in the aqueous phase). Another method is to simply use dilute nitric acid as a stripping agent for the plutonium. This PUREX chemistry is a classic example of a solvation extraction General Procedure for Experiments on a Centrifugal LLC Instrument Performing an LLC experiment on a centrifugal instrument usually follows most of the steps outlined below: 1. Find a suitable solvent system The HEMWat system is well tried and tested and proves adequate for most separations 2. Perform partition studies with different steps in the HEMWat series, with and without, acidic or basic modifiers if there are ionisable species present in the sample to be purified. Determine partition coefficient/distribution ratio (D and 1/D) for phases, examine the D and 1/D values to ascertain whether resolution is feasible. D ≥ 0.5 usually produces a satisfactory separation 3. The results of step 2 show whether the experiment should be performed in NP or RP mode. D ≈ 1 i.e. in the range of approximately 0.5 – 2.5 (the sweetspot), for a component of interest is desirable NP mode: the more polar phase is designated as SP. For the HEMWat series this is always the lower phase 4. Prepare the solvent mixture chosen for the separation and separate the phases 5. Perform scouting experiments and refine the experimental conditions or preparative runs as described in steps 6 - 9 10
  • 11. 6. Set up the instrument with respect to the choice for SP and fill the column with the chosen SP at the highest usable flow rate 7. Equilibrate the column with MP at the chosen elution flow rate. This step will displace some quantity of SP and from the displaced volume and the system and column volumes the initial SP retention can be calculated. These data allow prediction of elution volumes and times for the components of interest 8. Dissolve the appropriate quantity in a volume, equal to or less than 5 – 10% of the column volume, of either phase or preferably a mixture of the phases 9. Inject the sample, perform the elution, collect fractions and analyze then work up the required fractions Control of CCC selectivity is effected when using a stepped polarity solvent combination series such as Solvent combinations in the series are formed by mixing hexane or heptanes, ethyl acetate, methanol and water in different proportions to produce biphasic mixtures. The figure shows how retention and selectivity change as the test mixture. Benefits of using LLC  No expensive, fragile solid phase used and a ‘fresh’ column for every experiment.  Does not require dedication of particular columns to particular separations to avoid the risks of cross-contamination  As long as a chosen solvent combination forms two, readily separable, approximately equal volume layers there are few restrictions on solvent and additive choices 11
  • 12.  When compared with the widely used high performance technique of RP-SLC, solute capacities are high  The technique is readily scalable from mg directly to kg separations without the attendant problems often encountered when scaling up SLC separations  Tolerant of viscous and particulate-containing samples and require little or no sample preparation.  Separations of ‘dirty’ matrices do not usually require pre-chromatography prior to the high resolution step  Experiments can usually be run in NP so that fractions are collected in essentially organic solvent solution and so are easily worked up  There are no unpredictable and/or difficult to control, secondary chromatographic interactions to interfere with good resolution. Applications 12
  • 13. DNA purification: The ability to purify DNA from a sample is important for many modern biotechnology processes. However, samples often contain nucleases that degrade the target DNA before it can be purified. It has been shown that DNA fragments will partition into the light phase of a polymer–salt separation system. If ligands known to bind and deactivate nucleases are incorporated into the polymer phase, the nucleases will then partition into the heavy phase and be deactivated. Thus, this polymer–salt system is a useful tool for purifying DNA from a sample while simultaneously protecting it from nucleases. • Food Industry: The PEG–NaCl system has been shown to be effective at partitioning small molecules, such as peptides and nucleic acids. These compounds are often flavorants or odorants. The system could then be used by the food industry to isolate or eliminate particular flavors Liquid-Solid Chromatography (LSC) This type of chromatographic technique is also called adsorption chromatography since the mechanism of separation depends on adsorption of solutes on the stationary phase. The stationary phase is a solid which is usually silica or alumina with the former being most widely used. The retention times of some compound categories are as follows:Carboxylic acids > amides > amines ~ alcohols > ketones ~ aldehydes ~ esters >nitrocompounds > halides > hydrocarbons. Mobile Phase Selection The only factor that is used to optimize α and k’ is the mobile phase composition since the stationary phase is a solid. Great variations in α and k’ can be obtained by variations in nature and composition of the mobile phase. The polarity index of solvents can be used as a guide for estimating the polarity index of the mobile phase. However, a better scale is optimally dependent upon the adsorption energy per unit area of the solvent which is called the eluent strength, εo. The values of the eluentstrength are related to the polarity index. In selecting a mobile phase, two miscible solvents are used one with high eluent strength while the other with low eluent strength. k’ is then optimized by variation of the volume ratio of the two solvents. A small increase in εo value will significantly change k’. Therefore, large variations in k’ are possible by variation in mobile phase 13
  • 14. Composition. In case of getting overlapping peaks but acceptable k’, the type of mobile phase constituents must be changed in order to change α. It is usually possible to carry a thin layer chromatographic separation to optimize the mobile phase composition with regards to both eluent strength and composition Applications of Adsorption Chromatography LSC is best suited for the separation of non polar compounds with molecular weights below 5000. Solutes must be soluble in non polar solvents and should have a limited solubility in aqueous solvents. It should be remembered that the mobile phase in LSC should be non polar modified with a polar solvent. However, the solvent polarity must not be very large since irreversible adsorption on the stationary phase can occur precluding the use of LSC. Therefore, water is usually excluded from mobile phases to be used in LSC. Separations of difficult to separate isomers were possible with LSC. Ion-Exchange Chromatography (IEC or IC Separation of ionic species is efficiently done using ion-exchange chromatography (IEC) or simply ion chromatography (IC). Anions can be separated on an anionic exchange resin while cations can be separated on a cationic exchange resin. Separation of ionic species is efficiently done using ion-exchange chromatography (IEC) or simply ion chromatography (IC). Anions can be separated on an anionic exchange resin while cat ions can be separated on a cationic exchange resin. Ion-Exchange Resins and Equilibria Cationic exchange resins are mainly of two types: 14
  • 15. a. Sulfonic acid group like ~SO3 H+ b. Carboxylic acid group, ~COOH+ Anionic exchange resins are mainly of the tertiary amine type, ~(CH3)3N+ OH The cationic exchange equilibria can be represented by the equation n RSO3 - H+ (solid) + Mn+ = (RSO3 -)n Mn+ (solid) + n H+ For singly charged cations like B+, we may write:RSO3- H+(s) + B+(aq) = RSO3 - B+(s) + H+ (aq) kex = [RSO3 Ion-Exchange Resins and Equilibria Cationic exchange resins are mainly of two types: a. Sulfonic acid group like ~SO3H b. Carboxylic acid group, ~COO-H+ Anionic exchange resins are mainly of the tertiary amine type, ~(CH3)3N+ OH Thecationic exchange equilibria can be represented by the equation: n RSO3- H+ (solid) + Mn+ = (RSO3-)n Mn+ (solid) + n H+ For singly charged cations like B+, we may write: RSO3 H+ (s) + B+(aq) = RSO3- B+(s) + H+ (aq) kex = [RSO3- B+]s[H+]aq/[ RSO3 - H+]s[B+]aq - B+]s[H+]aq/[ RSO3 - H+]s[B+]aq Ion-Exchange Resins and Equilibria Cationic exchange resins are mainly of two types: a. Sulfonic acid group like ~SO3 H+ 15
  • 16. b. Carboxylic acid group, ~COOH+ Anionic exchange resins are mainly of the tertiary amine type, ~(CH3)3N+ OH The cationic exchange equilibria can be represented by the equation: n RSO3- H+ (solid) + Mn+ = (RSO3-)n Mn+ (solid) + n H+ For singly charged cations like B+, we may write: RSO3- H+(s) + B+(aq) = RSO3- B+(s) + H+ (aq) kex = [RSO3- B+]s[H+]aq/[ RSO3- H+]s[B+]aq kex = [RSO3- B+]s[H+]aq/[ RSO3- H+]s[B+]aq K = Cs/CM = [RSO3- B+]s/[B+]aq Where, K is the distribution constant. Therefore, kex represents the affinity of the resin RSO3 - H+ to cation B+ relative to cation H+. The affinity or kex is different for different ions and will depend on size and charge of ions .The anionic exchange equilibria can be represented by the equation: n R(CH3)nN+ OH- (solid) + An- = (R(CH3)nN+)n An- (solid) + n OH. Eluent Suppressor Columns Unfortunately, detectors available for use with IC are rather limited. Conductivity detectors are most common where simply ions will increase the conductivity. A major drawback to using conductivity detectors is the high salt concentration in the mobile phase which may make it very difficult to determine differences in conductivity, especially at low solute concentrations. The problem of high salt content of the mobile phase was solved by the use of what is called suppressor columns. The suppressor column is packed with a second ion exchange resin that converts the ions in the mobile phase to molecular species of limited ionization. For example, for the separation of cations, HCl is used as the eluent and the suppressor column in this case is packed with a hydroxide anion exchange packing. The following equilibrium takes place in the suppressor column: 16
  • 17. H+aq + Claq+ Resin+ OH- (solid) = Resin+ Cl- (solid) + H2O For separations of anions, the suppressor column contains a hydrogen ion cationic exchange resin and the eluent is a carbonate/bicarbonate mobile phase. The following equilibrium takes place: Na+aq + HCO3-aq + Resin- H+ (solid) = Resin+ Na+ (solid) + H2CO3 (aqueous) H2CO3 (aqueous) is a weak electrolyte which will contribute very little to conductivity. Therefore, in both cases the conductivity of the mobile phase was eliminated using suppressor .Parameter Effect on retention in anion IC The Mobile Phase The mobile phase transports the sample through the system and affects both retention and selectivity of the separation. The mobile phase is usually a solution of a salt in water, which works as a buffer, providing a stable pH. Several considerations govern the choice of a mobile phase. The first factor is the kind of sample ions that will be separated, but the type of separation column is also important. For catinic separations, HCl is a most common mobile phase while the two most common mobile phases for anionic separations are based on hydroxide or carbonate as eluting anion. In carbonate based mobile phases, the eluent is an aqueous solution of carbonate and hydrogen carbonate salts, where the ionic strength of the mobile phase and the ratio of the bicarbonate/carbonate ions can be varied to optimize the retention time and selectivity. The elution strength of the mobile phase and, to some extent, its selectivity, are affected by the type of ions of the eluent. A change of salts will normally result in a change of the eluent pHcolumns of suitable packing. Ionic strength 17
  • 18. The eluting ability of a mobile phase will increase as the ionic strength of the mobile phase is increased. However, the change in the selectivity among equally charged ions is very small, whereas the selectivity between ions of different charges (mono- or polyvalent) is far more sensitive to changes in ionic strength. PH The charge of the sample ions of weak acids or bases are controlled by the eluent pH and thus the retention times of such species will be affected by changes in Ph Temperature The ion exchange rate between the stationary and the mobile phase increases with increasing temperature. The viscosity of the eluent, and thereby the column backpressure, decreases and can give a better separation efficiency. The temperature can also affect the column selectivity. Isocratic and Gradient Elution The most common type of elution in IC is isocratic where the mobile phase has a constant composition during the entire run. Gradient elution where the eluent concentration is changed during the run can also be used. Gradient elution is effective when sample contains ions with widely different retention times. Hydroxide eluents are usually used for gradient elution in anion chromatography. By gradually increasing the concentration of hydroxide ions, the eluting power of the mobile phase increases. As a result, ions with high retention stay at the top of the column They 18
  • 19. then elute in sequence as sharp peaks. After each gradient run the column must be regenerated by pumping initial mobile phase for say 10-20 min (reproducibly getting the same baseline. COUNTER CURRENT CHROMATOGRAPHY COLUMS: From numerous column designs used to retain a liquid stationary phase [5–9], only two have had the potential for sustained commercial development. They are called the hydrostatic and the hydrodynamic configurations. Hydrostatic CCC columns: The very first hydrostatic CCC columns used gravity to maintain the liquid stationary phase; they were called droplet CCC (DCCC) columns. They needed very long elution times .The columns are no longer in use today. Modern hydrostatic CCC columns are known and marketed under the name of centrifugal partition chromatographs Their two main characteristics are: they have a single axis of rotation generating a constant centrifugal field and they enclose geometrical volumes, tubes, channels, or locules that repeat themselves through connecting tubes forming a pattern .It can be seen that there is quite a significant volume of connecting ducts which only contain the mobile phase. 19
  • 20. The liquid motion in CCC columns. A – Hydrostatic olumns or CPCs. There are a single axis of rotation producing constant centrifugal field and no phase exchanges in the connecting ducts. B – Hydrodynamic columns. There are a variable and cyclic centrifugal field produced by the planetary rotation of the bobbin around its own axis and the central rotor axis. There is contact between the two liquid phases throughout the tubing. The mobile phase is pictured in black, the stationary phase is white. This design reduces the contact time for solute exchange with the stationary phase. It also builds a small hydrostatic pressure that explains the significant pressure drop needed to operate hydrostatic centrifuges. All hydrostatic centrifuges contain two rotary seals; one at the top and the other one at the bottom. They are quiet to operate. In the toroidal coil CCC (helix CCC) system operated under a centrifugal force, the dimensions of the coil are reduced to that which is convenient for analytical separations. The coil is mounted around the periphery of the centrifugal bowl so that the stable radially acting centrifugal force field retains the stationary phase in one side of the coil as in the basic hydrostatic system described above. Hydrodynamic columns: Hydrodynamic Counter current Chromatography columns Hydrodynamic centrifuges used in the CCC columns have two rotational axes, a main axis and a planetar one which generates a variable centrifugal force field. There can be any number of planetary axes but the most common are single, double, and triple axes. Each planetary axis has a bobbin or spool mounted on it that contains the coils of continuously wound Teflon tubing In hydrodynamic columns, it is important to know the ratio of the spool radius, r, over the rotor radius, R. This ratio was traditionally termed is defined in LC as the phase ratio. 20
  • 21. The tubing can be connected from the outside of the centrifuge, wound round the bobbins, and passed back to the outside again without any rotary seals—hence, from the chromatography point of view it is equivalent to one long thin continuous column. The variable force field produces mixing and settling zones throughout the whole length of the coiled column as indicated in Fig. 2B. There is continuous contact between the two liquid phases throughout the column with no significant pressure buildup. Hydrodynamic centrifuges work with low mobile-phase pressure but can generate noise from the gear assembly, which can be reduced in well-designed centrifuges. These columns are often called highspeed CCC (HSCCC) columns since they can operate much more rapidly than the Craig, DCCC, and gravity-based columns. Table 1 compares the features of the two kinds of CCC columns. It is not possible to say that one kind is clearly superior to the other. The best situation is to have both kinds of CCC column to cover all possible cases. Studies are going on to develop large-scale CCC centrifuges based on both types being able to produce significant mass of purified material (preparative CCC) [13–15]. Such centrifuges can be used to produce standard reference materials for analytical purposes and to purify analytical reagent INSTRUMENTATION: force of 1g (the earth’s gravity) which was not very effective at stabilising the SP. Furthermore, the scope was limited since only the more dense phase could be used as the SP. Apart from these issues runs could take many days even with the later, mechanized and automated versions. 21
  • 22. The time required to perform experiments could run into days but the instruments were capable of resolving very complex mixtures. The technique was recognised to be gentle and offered high resolution and enjoyed favour as the purification method of choice for high value products such as Chinese medicines and other natural products with many groups of chromatographers. The methodology became, and until recent years remained, a niche application and was a technique very rarely employed by medicinal chemists. The other significant 1g instrument was the Droplet Countercurrent Chromatograph, DCCC, which was invented by Ito (see below) and his group in 1970. These instruments also relied on the earth’s gravity alone to stabilise the stationary phase whilst MP was pumped through the instrument but like the Craig machines, SP retention (stabilisation) was poor even at very low flow rates and experiments could take days to complete. However, these instruments were able to use either phase as SP although a significant disadvantage of these instruments was that phase mixing, an essential pre-requisite of successful LLC, was poor. DESCRIPTION OF CRAIG’S TECHNIQUE A schematic representation of five stagcs in the Craig s technique of counter cirrent extraction. The process of separation is carried cut by extracting a solution ofthc sample under test with an immiscible solvent. According to Craig, thi step is called ‘transfer’(n 0) and is shown i.n the top row of the figure. The vessel in which the initial extraction is allowed to take place, has been labelled ‘tube zero’ (r= 0). The figure.also indicates four other additional vessels labelled tubes. 12,3 22
  • 23. and 4. These vessels are a part of a very large numbe of identical containers. All of these vessels contain organic solvent a mobilc one and assuming for convenience that the weight Of solute is 1000 mg. and its partition ratio between the solvents is 1.00. It is also assumed that the volume of the organic solvent is identical to that of aqueous phase. Thus when equilibrium is achieved-in tube 0 after transfer, 0.500 mg. of solute will be found in each phase. • The next step in the process (transfer no.1.) involves transfer of the organic solvent from tube 0 to tube 1. This is also followed by an identical amount of fresh organic solvent into tube 0. When both vessels are shaken, the solute will be distributed among the four solutions as indicated inline n=1 of the figure 3. This process of transfer and equilibrium is epeated with an identical vôlume of fresh organic solvent being added to tube 0 at each transfer. The distribution of solute after four transfers (n 4) has been depictcd in line 4, where it will be seen that solute has become dist’ributed among all tubes. Figure 4 indicates the movementof the so,lute for a much large number of transfers, when the fraction of total solute contained in the two layers of each tube (i.e., organic portion + aqueous portion) is plotted agailist the tube number. It has- been found thatthe distribution curves become broader’ and lower, with an increased number of transfers. It should also be noted that for a solute with partition ratio larger than unity, the movement will be enhanced. 23
  • 24. DERIVATION OF DISTRIBUTION CURRENT The partition ratio data may be made use of in deriving the distribution curves, such as those slown in fig. 4. Suppose fn.r be the fraction of the initial solute A present in tube r after n transfers have been performed. Thus the sum of th total fractions must be equal to unity. That is, f.o+ fn + f2+ f3t .. 1 We know that the partition ratio in all tubes is given by,C- where - Cm= Concenratinof solute in the mobile phase. C5 = Concentration of solute in stationary phase. If now x is designated as the fraction of’öute found in the mobile organic phase of any tube and y as the fraction found in thetationary aqueoupiase, then x+ y= 1 In any particular tube, the amount of solute found in eaëh phase is given by, weight in mobile organic phase Cm . Vm. weight in stationary aqueous phase = C. V5 ‘ -V ri’ iho volumes of the two phases in millilitres ahd C, and C are expressed in grams per znillilitres. Thus, 24
  • 25. and Substitution of equation (i) and rearrangement gives, It may be made Dlear by taking the following examples. I. For n = 0. At this stage the solute is found in tube 0 only. Thus, fo,o X+ y 1.00 since x and y are dependent only on K’ when the volumes are fixed. POSITION WHEN LESS DENSE LIQUID IS RECEIVED FROM PRECEDING TUBE AND DURING EQUILIBRATION 25
  • 26. (a) For r= 1. The solute in tube I comes.from the tranfer of the organic phase in tube 0, transfer 0, which contaiiied the fraction of the original solute. Hence. Now the transferred sDlute undergoes partition in tube 1. .A fraction x of the solute will remain in the organic layer and a fraction y will go into the aqueous layer. Since the values of x and y are same throughout we have (b) For r = 0. The solute present in tube 0 comes from the aqueous layer that ontains the fraction y of the original. Thus, 26
  • 27. (3) For n =2. Here, the distribution of solut occurs among tubes 0,1 and 2. (a) For r =2. The solute in tube 2 comes from the organic layer of tube 1, transfer I containing the fraction x2 of the original sample. • This fraction will be again distributed to give x2 of the organic layer and x2y in the aqueous layer of tube 2. • 27
  • 28. Solution— From(8) and (9), we have Putting n= 5, and 3 - r in equation (iv) 28
  • 29. APPLICATIONS OF CRAIG’S TECHNIQUE Craig’s technique has widely been dsed particularly in the field of biochemical’s. Many closely related compounds have been separated by making use of this technique. Craig himself had resolved a mixture of 10 amino acids, despite the fact that the partition ratio for some of these compounds differed by less than ?. 1. Complex mixtures of fatty acids, polypeptides nucleotides, aromatic amines, antibiotics and many other organic substances have been fully separated by. using counter current extraction. TECHNIQUES: Techniques CCC can be thought of as occurring in three stages: mixing, settling, and separation (although they often occur continuously). Mixing of the phases is necessary so that the interface between them has a large area, and the analyte can move between the phases according to its partition coefficient. A partition coefficient is a ratio of the amount of analyte found in each of the solvents at equilibrium and is related to the analyte's affinity for one over the other. The mobile phase is mixing with then settling from the stationary phase throughout the column. The degree of stationary phase retention (inversely proportional to the amount of stationary phase loss or "bleed" in the course of a separation) is a crucial parameter. Higher quality instruments have greater stationary phase retention. The settling time is a property of the solvent system and the sample matrix, both of which greatly influence stationary phase retention. 29
  • 30. Droplet Countercurrent Chromatography (DCCC) Droplet CCC is the oldest form of CCC. It uses only gravity to move the mobile phase through the stationary phase. In descending mode, droplets of the denser mobile phase and sample are allowed to fall through a column of the lighter stationary phase using only gravity. If a less dense mobile phase is used it will rise through the stationary phase; this is called ascending mode. The eluent from one column is transferred to another; the more columns that are used, the more theoretical plates can be achieved. The disadvantage of DCCC is that flow rates are low, and poor mixing is achieved for most binary solvent systems, which makes this technique both time- consuming and inefficient. High-Performance Countercurrent Chromatography (HPCCC) The operating principle of CCC equipment requires a column consisting of a tube coiled around a bobbin. The bobbin is rotated in a double-axis gyratory motion (a cardioid), which causes a variable gravity (G) field to act on the column during each rotation. This motion causes the column to see 30
  • 31. one partitioning step per revolution and components of the sample separate in the column due to their partitioning coefficient between the two immiscible liquid phases used. HPCCC works in much the same way as HSCCC but with one vital difference. A seven-year R&D process that has produced HPCCC instruments that generated 240 g, compared to the 80 g of the HSCCC machines. This increase in g-level and larger bore of the column has enabled a tenfold increase in through put, due to improved mobile phase flow rates and a much higher stationary phase retention. Countercurrent chromatography is a preparative liquid chromatography technique, however with the advent of the higher g HPCCC instruments it is now prossible to operate instruments with sample loadings as low as a few milligrams, whereas in the past 100s of milligrams have been necessary. Major application areas for this technique include natural products purification and also drug development. High-Speed Countercurrent Chromatography (HSCCC) The modern era of CCC began with the development by Dr. Yoichiro Ito of the planetary centrifuge and the many possible column geometries it can support. These devices make use of a little-known means of making non-rotating connections between the stator and the rotor of a centrifuge. (It is beyond the scope of this discussion to describe the method of accomplishing this. Any of the several books available on CCC . Functionally, the high-speed CCC consists of a helical coil of inert tubing which rotates on its planetary axis and simultaneously rotates eccentrically about another solar axis. (These axes can be made to coincide, but the most common or type J CCC is discussed here.) The effect is to create zones of mixing and zones of settling which progress along the helical coil at dizzying speed. This produces a highly favorable environment for chromatography. 31
  • 32. There are numerous potential variants upon this instrument design. The most significant of these is the toroidal CCC. This instrument does not employ planetary motion. In some respects it is very like CPC, but retains the advantage of not needing rotary seals. It also employs a capillary tube instead of the larger-diameter tubes employed in the helices of the other CCC models. This capillary passage makes the mixing of two phases very thorough, despite the lack of shaking or other mixing forces. This instrument provides rapid analytical-scale separations, which can nonetheless be scaled up to either of the larger-scale CCC instruments. Centrifugal Partition Chromatography (CPC) Centrifugal Partition Chromatography (CPC) was invented in the eighties by the Japanese company Sanki Engineering Ltd, whose president was the late KanichiNunogaki. CPC has been extensively developed in France starting from the late nineties. CPC uses centrifugal force to speed separation and achieves higher flow rates than DCCC (which relies on gravity). The centrifugal partition chromatograph is constituted with a unique rotor (=column). This rotor rotates on its central axis (while HSCCC column rotates on its planetary axis and simultaneously rotates eccentrically about another solar axis). With less vibrations and noise, the CPC offers a wider rotation speed range (from 500 to 2000 rpm) than HSCCC. That allows a better decantation and retention for unstable biphasic system (e.g., aqueous aqueous systems or Butanol/water systems). Basics of CPC: The CPC rotor is constituted by the superposition of disks engraved with small cells connected by head / tail ducts. These cells, where the chromatographic separation takes place, can be compared to lined-up separate funnels. The rotor is filled with the stationary phase, which stays inside the rotor thanks to the rotation speed, while the mobile phase is pumped through. CPC can be operated in either descending or ascending mode, where the direction is relative to the force generated by the rotor rather than gravity. According to the fast and permanent evolution of the cells design, the efficiency and flow rate with low back pressure are improved. The CPC offers now the direct scale up from the analytical apparatuses (few milliliters) to industrial apparatuses (some liters) for fast batch production. 32
  • 33. MODES OPERATE: Modes of Operation • Reverse phase - Aqueous phase mobile - The denser phase is pumped through as the mobile phase. • Normal phase - Organic phase mobile - The less dense phase is used as the mobile phase. • Dual-Mode: The mobile and stationary phases are reversed part way through the run. • Gradient Mode: The concentration of one or more components in the mobile phase is varied throughout the run to achieve optimal resolution across a wider range of polarities. For example, a methanol-water gradient may be employed using pure heptane as the stationary phase. This is not possible with all binary systems, due to excessive loss of stationary phase. • Elution Extrusion Mode (EECCC): The mobile phase is extruded after a certain point by switching the phase being pumped into the system. For example, during the Elution portion of a separation using an EtOAcwater system running head to tail, the aqueous mobile phase is being pumped into the system, . In order to switch to extrusion mode, organic phase is pumped into the system. This can be accomplished either with a valve on the inlet of single pump, or ideally with an integrated system of two or three pumps, each dedicated either to a single phase of a binary mixture, or to an intermediate wash solvent. This also allows for good resolution of compounds with high mobile-phase affinities. It requires only one column volume of solvent and leaves the column full of fresh stationary phase. 33
  • 34. pH Zone Refining: Acidic and basic solvents are used to elute analytes . Achieving Resolution in Counter Current Chromomatography Understanding how resolution is achieved in CCC is assisted by the use of the simple model of a series of separating funnels numbered, each containing, let’s say 10ml of ethyl acetate which has been pre-saturated with water and which will form the SP for our experiments. For our first experiment, 10ml of water, pre-saturated with ethyl acetate and 50 parts of a solute with a D value of , when partitioned between ethyl acetate and water, are added to the first funnel. The funnel is stoppered, shaken and the phases allowed to settle. At this point each of the phases will contain 25 parts of the solute. The lower aqueous phase is transferred to the second funnel and 10ml fresh pre-saturated water are added to. Both funnels are stoppered, shaken and allowed to settle. At this point, the phases in will each contain parts of the solute as will those in The lower aqueous phase of is transferred to, the lower phase of is transferred to and another portion of water is added to. All three are stoppered, shaken and allowed to settle. Each phase in will now contain parts will still contain 25 parts in each phase and the phases in will each contain part The process of transfer lower phases to next funnels, add fresh portion of pre-saturated water to, shake and settle are repeated. The solute distribution profile after the fifth iteration is shown at the bottom of the Study of the figure shows that the solute is effectively moving through the series of funnels with a Gaussian distribution and as the solute band progresses, the maximum, single funnel concentration decreases. After sixteen or so such iterations, the outermost funnels, are essentially devoid of solute and the solute is distributed between funnels with the highest concentration of solute around. The process of transfer lower phases to next funnels, add fresh portion of pre-saturated water to, shake and settle are repeated. The solute distribution profile after the fifth iteration is shown at the 34
  • 35. bottom. If a total of 100 iterations are completed and the concentrations plotted as in the solute is distributed over about 30 funnels with the maximum concentration found in funnel 50 or so as might be experted. Chromatographic Resolution Chromatographic resolution, i.e. complete separation of the components of a mixture, is the ultimate goal of a separation process. Such a process, performed on naturally occurring materials or those of synthetic origin, may involve many steps including techniques such as extraction, crystallization, distillation etc and may also include one or more chromatographic steps. It is these latter with which we are concerned i.e. the complete separation of the components of a mixture by means of a chromatographic process. In both research and production, the most widely used, high performance (resolution) chromatographic method is RP-HPLC. HPCCC is a high performance (high resolution) technique and some comparison with RP-HPLC is justified. The Snyder resolution equation, Equation 4, tells us that resolution is the product of an efficiency term, a selectivity term and a retention term, respectively. This means that in order to maintain a given resolution, if the value of any single term is reduced, then the value of one or both of the others must increase to compensate for the reduction. Retention is a critical factor in any chromatographic process and ultimately determines column capacity.shows a representation of the relative, characteristic SP and MP volumes in a HPCCC column compared with those in a bonded RP-HPLC column. It should be noted that although the active MP volume in both is much the same, in an HPCCC system the SP volume is much greater 35
  • 36. and furthermore that the ratio of SP/MP is inverted. This factor means that the dynamic mass capacity of the HPCCC column is much grater than that of a rp- hplc column HPLC chromatographers have only limited scope for improving selectivity, via Path B in the since C18 bonded phases differ little one from another and little more from, for example, a C8 bonded phase and the range of usable solvents is extremely limited so the usual solution to the problem for analytical chromatographers is via Path A in the figure, i.e. moving to a higher efficiency, smaller particle, packing. However, this is not a practicable proposition for preparative scale chromatographers since (large volume preparative columns filled with small particle media would be prohibitively expensive) and in any case there are currently no commercially available preparative scale pumps capable of pumping mobile phase through a large bed of sub-media at a practically useful flow rate. Under such circumstances the preparative scale solid-liquid chromatographer is stymied. An alternative solution is to find a methodology which rather than improving efficiency can exploit controllable selectivity, i.e. a CCC methodology. Even the relatively high, compared with other CCC methods, efficiency of HPCCC is still measured in only hundreds of plates compared with the thousands or tens of thousands of plates found in an equivalent sized SLC column but by exploiting the optimization of selectivity the technique is capable of high resolution. 36
  • 37. APPLICATION OF COUNTER CURRENT CHROMATROGRAPHY CCC is playing an increasingly important role in separation science. All components in the sample solution injected into the column can be recovered and irreversible adsorption and contamination of samples can be virtually eliminated. A crude sample can be injected directly into the column, which simplifies sample preparation. Now CCC is successfully used for the separation of organic and inorganic substances from a complicated mixture. ORGANIC SUBSTANCES; CCC has become a method of choice in natural products chemistry and has made possible the separation of a number of biologically interesting natural products that are difficult or impossible to separate by other techniques Crude extracts of plants or other organisms are often too complex for the direct analysis by HPLC. Certain materials may irreversibly bind to the packing material or may plug the column inlet filters, and hence reduce the column life. Those restrictions do not apply to analytical CCC, which represents an interesting method for enrichment and separation of various analytes. The technique is also used for the separation of bio chemicals and pharmaceuticals. CCC is especially suitable for the separation of alkaloids from medical herbs using simple solvent systems, for the total hormonal analysis of natural samples and for the screening of new bioactive compounds in crude extracts and other complex samples CCC has been also suggested as an alternative to the shake flask method to measure liquid–liquid partition coefficients as a way to characterize the lipophilic–hydrophilic nature of a compound ,below some interesting methods are briefly described which have been successfully used in the analysis of various samples or which can be applied to analytical purposes without serious modification of the procedures and apparatus. 37
  • 38. Analysis of plant and different natural products Different types of hydrodynamic (HSCCC, cross- axis coil) and hydrostatic (toroidal coil) centrifuges can be used for separation and concentration of various compounds from plant and different natural products. The quantity of separated compounds may range from trace to gram amounts. Toroidal coil Centrifuges Toroidal coil centrifuges have been successfully applied to the separation and purification of plant hormones,namely, indole auxins, gibberellins, cytokinins, and abscisic acid. Indole auxins were separatedby either hexane-ethyl acetate–methanol–water (volume ratio 0.6:1.4:1.0:1.0) or chloroform–acetic- acid–water (2:2:1) in a column with a total capacity of 18 mL. The latter solvent system was especially useful for the separation of abscisic acid from indole-3-acetic acid. Gibberellins (GA3, GA4, and GA7)were separated from each other in ether-methanol-phosphate buffer (pH 7) (3:1:2). The CCC method was suitable for the separation of four cytokinins in ethyl acetate-methanol-phosphate buffer (pH 7)(3:1:3) [2,4,5].A toroidal coil planet centrifuge for analytical-scale separations was used for the purification of abscisic acid (ABA) obtained from crude plant extracts and its determination in several plant tissues using HPLC and GC-MS [34].The results of the isolation of 3-oxo-5-steroid isomerase (KSI) from crude E. coli lysate were published [35]. A separation was performed on ca. 3 mg of 15N-labeled KSI using a polymer-containing system based on PEO 3350. The present method eliminates sample loss and denaturation caused by the solid support and yields pure proteins in both preparative and analytical separations . 38
  • 39. High-speed hydrodynamic centrifuges (HSCCC) Numerous applications in the analysis and preparation of natural products by CCC have been reported. Separation of poly phenolic natural products such as flavonoids are difficult because these compounds tend to show “peak tailing” in RP-HPLC, as well as irreversible adsorption on silica gel. Those difficulties do not exist in CCC and are the reason why CCC has been recognized as a most valuable technique for the isolation of polyphenols . The flavonoids and hydroxyanthraquinones can be easily separated by CCC with a high selectivity Zhang has published the results of the separation of alkaloids (from Stephania tetrandra S.Moore) using n-hexane–ethyl acetate–methanol–water systems at different volume ratios, hydroxyanthraquinones (from the rhizome of Rheum palmatum L.) using a system of hexane–ethyl acetate–methanol–water (9:1:5:5) and flavonoids (from sea buckthorn Hippophae rhamnoides) using a system of chloroform–methanol–water (4:3:2) by CCC; the total capacity of the column was 43 mL, the maximum revolution speed of centrifuge was 2000 rpm By increasing the flow-rate of the mobile phase in these analytical separations, the separation time for a crude sample mixture was shortened to within 15 min, which is quite comparable with that of analytical HPLC. Milligram and even gram amounts of substances can be isolated by the CCC technique. This makes it possible to produce standard reference materials for any analytical study. For the more efficient separation of compounds having a wide range of polarity, lower and upper phases of the solvent system were used as the mobile phase in succession. This method achieved a complete separation of five components present in a 1-mg sample mixture. The peak fraction of each compound was subjected to mass spectrometric analysis for compound structure confirmation shows the countercurrent chromatogram of five major compounds in the crude extract of rhizome of Rheum palmatum L. 39
  • 40. Three peaks were eluted with the upper phase in NP mode followed by two peaks which were eluted with the lower phase in RP mode. The results indicated that peaks were corresponding to chrysophanol, emodin, physcion, aloe-emodin, and rhein, respectively. CCC was used for the systematic selection and optimization of a two-phase solvent system to separate alkaloids from Coptis chinensis Franch using a system of chloroform–methanol–HCl solution. at different volume ratios .One separation run yielded four pure alkaloids, including palmatine, berberine, epiberberine, and coptisine from a crude alkaloid extract. Analytical application of CCC was successfully demonstrated for the separation of microgram quantities of flavonoids from a crude ethanol extract of sea buckthorn in a multilayer coil with a total capacity of 8 mL using a two-phase solvent system composed of chloroform–methanol–water (4:3:2) [43]. Five peaks, including isorhamnetin and quercetin, were well resolved and eluted within 8 min. An artificial mixture of three common plant coumarins (herniarin, scopoletin, and umbelliferone) and one flavanone (hisperetin) was separated 40
  • 41. with a hydrodynamic CCC column connected to a photodiode array detector. The lower phase of a chloroform–methanol–water. CONCLUSION: 41
  • 42. High Speed Counter Current Chromatography is a very good preparative separation technique. The use of support-free liquid stationary phase and no sample loss, with high separation efficiency and resolution by using the centrifugal field, are the characteristics that make it superior to all other separation techniques. As there is no solid support, it is free from adsorption of solutes to the column and the recovery of samples and reagents is without contamination or decomposition. Another advantage is that it is possible to use the same column repeatedly for separations, with different stationary phases. The use of HSCCC in drug discovery and product development where there is ease of scale-up from milligrams to grams and then to kilograms, makes it an excellent technique for the separation of natural pigments and other bioactive constituents, which are present in minute quantities.HPCCC is an orthogonal and complementary chromatography technique to HPLC in the armamentarium available to separation scientists and worthy of a place in the chromatographer’s toolbox. Neither HPCCC, nor any other modern LLC methodology, is a ‘magic bullet’ solution but with controllable, tunable selectivity it is able to very effectively tackle problems that are difficult or totally intractable when HPLC is used. In many instances the use of selectivity instead of efficiency can prove to be the optimal way of separating components, especially from whenever preparative quantities require purification. More and more chromatographers are realizing the real benefits that accrue from the use of LLC. The list of applications of LLC grows day by day REFERENCES 42
  • 43. 1. Dr.S. Ravi shankar 2. B.K.sharma 3. Sikdar, Cole, et al. Aqueous Two-Phase Extractions in Bioseparations: An Assessment. Biotechnology 9:254. 1991 4. Szlag, Giuliano. A Low-Cost Aqueous Two Phase System for Enzyme Extraction. Biotechnology Techniques 2:4:277. 1988 5. Dreyer, Kragl. Ionic Liquids for Aqueous Two-Phase Extraction and Stabilization of Enzymes. Biotechnology and Bioengineering. 99:6:1416. 2008 6. Boland. Aqueous Two-Phase Systems: Methods and Protocols. Pg 259-269 7. 11. A. Berthod, B. Billardello. Advances in Chromatography, Vol. 40, P. Brown, E. Grushka (Eds.), 8. p. 8, Marcel Dekker, New York (2000). 9. 12. A. Berthod. In Centrifugal Partition Chromatography, A. P. Foucault (Ed.), Chromatographic 10. Science Series, Vol. 68, p. 167, Marcel Dekker, New York (1995). 11. I. A. Sutherland, J. de Folter, P. L. Wood. J. Liq. Chromatogr. Rel. Technol. 26, 1449 (2003). 12. P. L. Wood, D. Hawes, L. Janaway, I. A. Sutherland. J. Liq. Chromatogr. Rel. Technol. 26, 1373 13. (2003). 14. A. Marston, K. Hostettmann. J. Chromatogr., A 658, 315 (1994). 15. Y. Ito. J. Chromatogr., A 1065 16. 11. A. Berthod, B. Billardello. Advances in Chromatography, Vol. 40, P. Brown, E. Grushka (Eds.), 17. p. 8, Marcel Dekker, New York (2000). 43
  • 44. 18. 12. A. Berthod. In Centrifugal Partition Chromatography, A. P. Foucault (Ed.), Chromatographic 19. Science Series, Vol. 68, p. 167, Marcel Dekker, New York (1995). 20. 13. I. A. Sutherland, J. de Folter, P. L. Wood. J. Liq. Chromatogr. Rel. Technol. 26, 1449 (2003). 21. 14. P. L. Wood, D. Hawes, L. Janaway, I. A. Sutherland. J. Liq. Chromatogr. Rel. Technol. 26, 1373(2003). 22. 15. A. Marston, K. Hostettmann. J. Chromatogr., A 658, 315 (1994). 23. 16. Y. Ito. J. Chromatogr., A 1065,, 24. . Oka. In High-Speed Countercurrent Chromatography, Y. Ito, W. D. Conway (Eds.), p. 73, John 25. Wiley, Chichester (1996) 26. Kanichi Nunogaki was invented centrifugal partition chromatography japans company engineering limited whose president 27. Coptis chinensis was invented counter current chromatography .for the development of applications 44
  • 45. 18. 12. A. Berthod. In Centrifugal Partition Chromatography, A. P. Foucault (Ed.), Chromatographic 19. Science Series, Vol. 68, p. 167, Marcel Dekker, New York (1995). 20. 13. I. A. Sutherland, J. de Folter, P. L. Wood. J. Liq. Chromatogr. Rel. Technol. 26, 1449 (2003). 21. 14. P. L. Wood, D. Hawes, L. Janaway, I. A. Sutherland. J. Liq. Chromatogr. Rel. Technol. 26, 1373(2003). 22. 15. A. Marston, K. Hostettmann. J. Chromatogr., A 658, 315 (1994). 23. 16. Y. Ito. J. Chromatogr., A 1065,, 24. . Oka. In High-Speed Countercurrent Chromatography, Y. Ito, W. D. Conway (Eds.), p. 73, John 25. Wiley, Chichester (1996) 26. Kanichi Nunogaki was invented centrifugal partition chromatography japans company engineering limited whose president 27. Coptis chinensis was invented counter current chromatography .for the development of applications 44