Shivani Scientific Industries (P) Ltd has vast experience of more than 20 years of designing and building pharmaceutical Laboratories as per WHO-GMP norms with stringent requirement of sterility. The same experience has helped us to fulfill the demanding needs of to-days IVF Labs.
A new Lab means start contacting designers, architects, sellers, resellers, vendors, suppliers, agents, distributors to initiate slow, long and laborious process of discussing dates and negotiating rates. This, you will agree, will further eat into your most precious commodity "Time".
3D Lab design / 3 D Walk through
We offer State of the Art computer modeling to visualize your Lab either in 3D or 3D Walk through, even before your lab is ready.
Customised Video Processing
All modern equipments comes with all provision of image processing which is very well utilized by our Combination of hardware camera selection and software selection. Multiple Camera inputs can be synthesised in one system to have better recording and processing.
Embryology Services
We provide assistance in providing complete embryology services from Ovum Pick-up to embryo transfer. Qualified and experienced team of clinicians and embryologists are selected to provide these services.
Air Quality evaluation and improvement
We have capability to thoroughly evaluate Air quality on existing Lab and recommend appropriate steps to improve the same. It varies from HVAC inspection to microbial air sampling.
Hands on training for Lab Staff
We offers comprehensive hands on training in collaboration with Maharashtra Animal & Fishery Sciences University to Lab Staff.
Annual Maintenance of IVF Lab Equipments
We undertake Annual Maintenance Contracts for IVF Labs with the support of its highly qualified team of Engineers. We also cater to calibration contracts with our highly accurate calibration equipments.
Alternatively you have the easier and simpler option: Contact US for::
OUR PRODUCT RAGE IS:::
IVF PRODUCTS WE MAKE:
Spermfuge,Mobile Nest,Lab Guard,Warming Blocks,Ivf lab Turnkey Projects,Rapid Recovery System
IVF Division:::WE SUPPLY
Spermfuge,ThermoPlate,Embryo Freezer,System for ART,Suction Pumps for oocyte aspiration,
CO2 incubator,warming block,micromanipulator,Microscope,Micropipettes,Clean Air System,
FertAid,Embryology Academy of research Training.
Autoclaves & Sterilisers:::WE MAKE
Double Wall,Autoclave,Laboratory Autoclaves,Semi Automatic,Portable Autoclave,
Semi Automatic,Gas cum Electric,Autoclave Horizontal Sterilizer,
Fully Automatic Autoclaves GMP Compliant Series,Acculeak Detector
setup ivf lab in Africa,setup your ivf lab in India,worldwide ivf clinics
1. TECHNICAL SPECIFICATION
Blower-German make : Backward impeller type
Pre Filter : Synthetic PU washable
Hepa Filter : Efficiency 99.97% @ 0.3 microns
VOC Filter: : Unique blend of activated carbon and alumina
Unit capacity: : 350 CFM
Lab Guard
Mounting: : To be done outside VF Lab on any Wall
Power consumption: : 90 Watts maximum
Filter replacement as per auto indication
Electrical supply : 100/110 volts OR 220/240 volts 50/60 Hz
Positive Pressure System
specifications subject to change without notice
Ordering information
LG 300
Lab Guard LG 300 100 120 Volts 60 Hz order code FX 2045
Lab Guard LG 300 220 240 Volts 50 Hz order code FX 2046
Spare Filter Set order code FX 2047
Return Blower order code Fx 2048
Dimensions
590 mm 470 mm
800 mm
Traceability calibration in accordance with
C For more details go to
national and international standards, NIST USA
www.shivaniscientific.com
Q Individual and expressive quality control certificate
Shivani Scientific Industries (P) Ltd
Tel - + 91 22 2845 6768
26A Raju Industrial Estate, Penkar Pada Road
+ 91 22 2845 6769
Near Dahisar Check Naka, Mira-401104
+ 91 22 2845 6770
Dist. Thane (Mumbai) Maharashtra, INDIA
e-mail sales@shivaniscientific.com Fax - + 91 22 2845 7140
ssipl@bom5.vsnl.net.in + 91 22 2845 6766
Distributor
We make it possible
Guard
Lab Pressure System
Positive
Lab Guard
LAB GUARD
Split A/C
Positive Pressure System DESIGN
The LAB+GUARD has been designed with State
IVF LAB
LG 300 of the Art technology using 4 stage filtration UTILITY
system. The unique filter combination filters out ROOM
LAB GUARD
air and gas contaminant thus by giving most
suitable air for gametes and embryos.
LAB+GUARD system contains a unique 4 stage
Blower
Return
filtration system containing Prefilter, Hepa Filter
and unique blend of activated carbon and
alumina, which ensures wide variety of Gases,
particular contaminants are oxidized or are
CONCEPT Fresh Air
absorbed. The LAB+GUARD has been designed
to reduce the microbial air flora to the minimum
The LAB+GUARD is developed to improve the
level.
OPERATING SECURITY RETURN BLOWER
laboratory air quality making it nearly equal to
clean air. Thus replenishing and subsequently
REDUCES CFU, REDUCES VOC The return blower is utilised to circulate back the
Every care has been taken in designing to make
nourishing the entire laboratory, making it safe for
air of IVF lab to room where LAB+GUARD has
sure that air absorbed is thoroughly cleaned
The unique design and the concept of
the sensitive procedures to be executed. This is
been fitted.
for contaminants and to reduce bacterial count in
LAB+GUARD positive pressure system not only
achieved by a number of inclusions and their
IVF Lab. The LAB+GUARD design also facilitates
reduces VOC content in the air but also the CFU
applications all of which are simple, cost effective
introduction of fresh air into the air circuit which UPGRADING, EXPANDING OR
count in the IVF Lab. The LAB+GUARD not
and user friendly.
gives maximum safety from Carbon dioxide
only protects embryos and gammas but also SETTING UP NEW IVF LAB?
The positive pressure system uses the basic
released into the IVF Lab by CO2 Incubators and
protects embryologists who is the most affected
principle of “Over Pressure or positive pressure in
also it protects embryologists from gas mixtures The LAB+GUARD team helps you in evaluation of
otherwise.
a room which restricts the entry of outside air”.
released on work stations. possibilities to improve air quality in your lab. If
This is achieved by absorbing the circulating air
you are upgrading, expanding or setting up new
outside the IVF Lab (Room) and then
lab contact us for technical assistance.
CHANGE FILTERS AS PER USAGE
subsequently passing the same through a series
of 4 stage filters thus making it quite IVF friendly.
The LAB+GUARD also houses a unique
Thus ultimately the effective, circulating air in the
automatic indication system whereby the user is
WHO BREATHS CO2
IVF lab reaches a near clean air status, provides a
informed when to change the filters, and not
positive pressure, reduces the CFU count, IN YOUR IVF LAB ?
“every quarterly”. This feature not only gives
eliminates the SPM, VOCs and CACs.
tremendous relief to the user for tracking the If your lab does not have regulated fresh air intake or
stipulated time of change but also saves lot of positive pressure design, there are every chances
ENSURE NET FLOW OUT money.
that your embryologists are breathing out CO2 tanks
In any HVAC/air flow design it is essential that net
MAINTENANCE emptied ever year. Since CO2 can not be absorbed
flow is going out of the room. This means room air
or filtered by Indoor air purifiers or filters. The
volume and pressure should be slightly higher The LAB+GUARD has automatic indication for
LAB+GUARD facilitates introduction of fresh air and
than adjoining areas/rooms. This will keep out Filter change and the design facilitate extremely
any toxic fumes trying to come in. IVF labs which easy replacement of filters even by non technical reduces the risk of high CO2 concentration into the
are not having adequate positive pressure are staff. Other than filter change it is virtually IVF Lab.
suceptible to risk of contamination. maintenance free.