Submit Search
Upload
IRJET- Retrofitting of Reinforced Concrete Structures
•
0 likes
•
30 views
IRJET Journal
Follow
https://www.irjet.net/archives/V6/i3/IRJET-V6I3300.pdf
Read less
Read more
Engineering
Report
Share
Report
Share
1 of 6
Download now
Download to read offline
Recommended
IRJET- Repair and Rehabilitation of a Building
IRJET- Repair and Rehabilitation of a Building
IRJET Journal
IRJET- To Study and Analyze the Various Structures by the Structural Audit
IRJET- To Study and Analyze the Various Structures by the Structural Audit
IRJET Journal
IRJET- Structural Audit – A Case Study of Educational Building
IRJET- Structural Audit – A Case Study of Educational Building
IRJET Journal
IRJET-Understanding the Structural Audit
IRJET-Understanding the Structural Audit
IRJET Journal
IRJET- Analysis and Synthesis of Extrnally Plated Reinforced Concrete Beams
IRJET- Analysis and Synthesis of Extrnally Plated Reinforced Concrete Beams
IRJET Journal
IRJET- Review on Performance of Polypropylene Band–Retrofitted Masonry: Evalu...
IRJET- Review on Performance of Polypropylene Band–Retrofitted Masonry: Evalu...
IRJET Journal
IRJET - Failure in Commercial Building and Management - Case Study
IRJET - Failure in Commercial Building and Management - Case Study
IRJET Journal
Time, Cost , Productivity and Quality Analysis of Precast Buildings
Time, Cost , Productivity and Quality Analysis of Precast Buildings
IRJET Journal
Recommended
IRJET- Repair and Rehabilitation of a Building
IRJET- Repair and Rehabilitation of a Building
IRJET Journal
IRJET- To Study and Analyze the Various Structures by the Structural Audit
IRJET- To Study and Analyze the Various Structures by the Structural Audit
IRJET Journal
IRJET- Structural Audit – A Case Study of Educational Building
IRJET- Structural Audit – A Case Study of Educational Building
IRJET Journal
IRJET-Understanding the Structural Audit
IRJET-Understanding the Structural Audit
IRJET Journal
IRJET- Analysis and Synthesis of Extrnally Plated Reinforced Concrete Beams
IRJET- Analysis and Synthesis of Extrnally Plated Reinforced Concrete Beams
IRJET Journal
IRJET- Review on Performance of Polypropylene Band–Retrofitted Masonry: Evalu...
IRJET- Review on Performance of Polypropylene Band–Retrofitted Masonry: Evalu...
IRJET Journal
IRJET - Failure in Commercial Building and Management - Case Study
IRJET - Failure in Commercial Building and Management - Case Study
IRJET Journal
Time, Cost , Productivity and Quality Analysis of Precast Buildings
Time, Cost , Productivity and Quality Analysis of Precast Buildings
IRJET Journal
IRJET- Manufacture of Concrete using Solid Waste from Construction Industry
IRJET- Manufacture of Concrete using Solid Waste from Construction Industry
IRJET Journal
Comparative Study of Codal Provisions for Pre-Engineered Buildings
Comparative Study of Codal Provisions for Pre-Engineered Buildings
IRJET Journal
Fibers frca aci544_b
Fibers frca aci544_b
AsuSSEBENA
IRJET- Characterization of Aluminum 7085/WC/Fly Ash Hybrid Composites for...
IRJET- Characterization of Aluminum 7085/WC/Fly Ash Hybrid Composites for...
IRJET Journal
IRJET- Adoption of Pre-Fabricated Bathroom Units by Real Estate Developers
IRJET- Adoption of Pre-Fabricated Bathroom Units by Real Estate Developers
IRJET Journal
Experimental study on strength characteristics of concrete with recycled aggr...
Experimental study on strength characteristics of concrete with recycled aggr...
eSAT Journals
IRJET- Comparative Study of Concrete with Fibre
IRJET- Comparative Study of Concrete with Fibre
IRJET Journal
IRJET- Review on Effect of Process Parameter on Mechanical Properties of AL-B...
IRJET- Review on Effect of Process Parameter on Mechanical Properties of AL-B...
IRJET Journal
IRJET- Ultra High Performance Concrete on Bridges
IRJET- Ultra High Performance Concrete on Bridges
IRJET Journal
Chap 2-literature-review (3)
Chap 2-literature-review (3)
Jessyca Than
IRJET- An Investigation of Maintenance Management of Construction Equipment f...
IRJET- An Investigation of Maintenance Management of Construction Equipment f...
IRJET Journal
Fibers aci544
Fibers aci544
AsuSSEBENA
IRJET- Deburring Methods for Elimination of Chips in the Internal Tubes of Fr...
IRJET- Deburring Methods for Elimination of Chips in the Internal Tubes of Fr...
IRJET Journal
Construction Standards of Residential Buildings Post Handover
Construction Standards of Residential Buildings Post Handover
IRJET Journal
Strengthing of damaged structure
Strengthing of damaged structure
IAEME Publication
IRJET- Comparative Study of Multi-Storey Multi-Span G+4 Building by PEB and C...
IRJET- Comparative Study of Multi-Storey Multi-Span G+4 Building by PEB and C...
IRJET Journal
IRJET- Side Impact Glass Fiber Composite Beam and Enhanced Passenger Car ...
IRJET- Side Impact Glass Fiber Composite Beam and Enhanced Passenger Car ...
IRJET Journal
IRJET- Analysis of Thermal Behavior of Protected and Unprotected Slim Floor u...
IRJET- Analysis of Thermal Behavior of Protected and Unprotected Slim Floor u...
IRJET Journal
IRJET- Quality Assurance & Project Scheduling for Residential Building
IRJET- Quality Assurance & Project Scheduling for Residential Building
IRJET Journal
IRJET- Review on Restrengthening of Existing R.C Structure with Considera...
IRJET- Review on Restrengthening of Existing R.C Structure with Considera...
IRJET Journal
IRJET- U-Boot Technology
IRJET- U-Boot Technology
IRJET Journal
A Review of Effective Use of Fischer Chemical for Rebaring in Existing Concre...
A Review of Effective Use of Fischer Chemical for Rebaring in Existing Concre...
IRJET Journal
More Related Content
What's hot
IRJET- Manufacture of Concrete using Solid Waste from Construction Industry
IRJET- Manufacture of Concrete using Solid Waste from Construction Industry
IRJET Journal
Comparative Study of Codal Provisions for Pre-Engineered Buildings
Comparative Study of Codal Provisions for Pre-Engineered Buildings
IRJET Journal
Fibers frca aci544_b
Fibers frca aci544_b
AsuSSEBENA
IRJET- Characterization of Aluminum 7085/WC/Fly Ash Hybrid Composites for...
IRJET- Characterization of Aluminum 7085/WC/Fly Ash Hybrid Composites for...
IRJET Journal
IRJET- Adoption of Pre-Fabricated Bathroom Units by Real Estate Developers
IRJET- Adoption of Pre-Fabricated Bathroom Units by Real Estate Developers
IRJET Journal
Experimental study on strength characteristics of concrete with recycled aggr...
Experimental study on strength characteristics of concrete with recycled aggr...
eSAT Journals
IRJET- Comparative Study of Concrete with Fibre
IRJET- Comparative Study of Concrete with Fibre
IRJET Journal
IRJET- Review on Effect of Process Parameter on Mechanical Properties of AL-B...
IRJET- Review on Effect of Process Parameter on Mechanical Properties of AL-B...
IRJET Journal
IRJET- Ultra High Performance Concrete on Bridges
IRJET- Ultra High Performance Concrete on Bridges
IRJET Journal
Chap 2-literature-review (3)
Chap 2-literature-review (3)
Jessyca Than
IRJET- An Investigation of Maintenance Management of Construction Equipment f...
IRJET- An Investigation of Maintenance Management of Construction Equipment f...
IRJET Journal
Fibers aci544
Fibers aci544
AsuSSEBENA
IRJET- Deburring Methods for Elimination of Chips in the Internal Tubes of Fr...
IRJET- Deburring Methods for Elimination of Chips in the Internal Tubes of Fr...
IRJET Journal
Construction Standards of Residential Buildings Post Handover
Construction Standards of Residential Buildings Post Handover
IRJET Journal
Strengthing of damaged structure
Strengthing of damaged structure
IAEME Publication
IRJET- Comparative Study of Multi-Storey Multi-Span G+4 Building by PEB and C...
IRJET- Comparative Study of Multi-Storey Multi-Span G+4 Building by PEB and C...
IRJET Journal
IRJET- Side Impact Glass Fiber Composite Beam and Enhanced Passenger Car ...
IRJET- Side Impact Glass Fiber Composite Beam and Enhanced Passenger Car ...
IRJET Journal
IRJET- Analysis of Thermal Behavior of Protected and Unprotected Slim Floor u...
IRJET- Analysis of Thermal Behavior of Protected and Unprotected Slim Floor u...
IRJET Journal
IRJET- Quality Assurance & Project Scheduling for Residential Building
IRJET- Quality Assurance & Project Scheduling for Residential Building
IRJET Journal
What's hot
(19)
IRJET- Manufacture of Concrete using Solid Waste from Construction Industry
IRJET- Manufacture of Concrete using Solid Waste from Construction Industry
Comparative Study of Codal Provisions for Pre-Engineered Buildings
Comparative Study of Codal Provisions for Pre-Engineered Buildings
Fibers frca aci544_b
Fibers frca aci544_b
IRJET- Characterization of Aluminum 7085/WC/Fly Ash Hybrid Composites for...
IRJET- Characterization of Aluminum 7085/WC/Fly Ash Hybrid Composites for...
IRJET- Adoption of Pre-Fabricated Bathroom Units by Real Estate Developers
IRJET- Adoption of Pre-Fabricated Bathroom Units by Real Estate Developers
Experimental study on strength characteristics of concrete with recycled aggr...
Experimental study on strength characteristics of concrete with recycled aggr...
IRJET- Comparative Study of Concrete with Fibre
IRJET- Comparative Study of Concrete with Fibre
IRJET- Review on Effect of Process Parameter on Mechanical Properties of AL-B...
IRJET- Review on Effect of Process Parameter on Mechanical Properties of AL-B...
IRJET- Ultra High Performance Concrete on Bridges
IRJET- Ultra High Performance Concrete on Bridges
Chap 2-literature-review (3)
Chap 2-literature-review (3)
IRJET- An Investigation of Maintenance Management of Construction Equipment f...
IRJET- An Investigation of Maintenance Management of Construction Equipment f...
Fibers aci544
Fibers aci544
IRJET- Deburring Methods for Elimination of Chips in the Internal Tubes of Fr...
IRJET- Deburring Methods for Elimination of Chips in the Internal Tubes of Fr...
Construction Standards of Residential Buildings Post Handover
Construction Standards of Residential Buildings Post Handover
Strengthing of damaged structure
Strengthing of damaged structure
IRJET- Comparative Study of Multi-Storey Multi-Span G+4 Building by PEB and C...
IRJET- Comparative Study of Multi-Storey Multi-Span G+4 Building by PEB and C...
IRJET- Side Impact Glass Fiber Composite Beam and Enhanced Passenger Car ...
IRJET- Side Impact Glass Fiber Composite Beam and Enhanced Passenger Car ...
IRJET- Analysis of Thermal Behavior of Protected and Unprotected Slim Floor u...
IRJET- Analysis of Thermal Behavior of Protected and Unprotected Slim Floor u...
IRJET- Quality Assurance & Project Scheduling for Residential Building
IRJET- Quality Assurance & Project Scheduling for Residential Building
Similar to IRJET- Retrofitting of Reinforced Concrete Structures
IRJET- Review on Restrengthening of Existing R.C Structure with Considera...
IRJET- Review on Restrengthening of Existing R.C Structure with Considera...
IRJET Journal
IRJET- U-Boot Technology
IRJET- U-Boot Technology
IRJET Journal
A Review of Effective Use of Fischer Chemical for Rebaring in Existing Concre...
A Review of Effective Use of Fischer Chemical for Rebaring in Existing Concre...
IRJET Journal
“Structural Audit and Rehabilitation of Building”
“Structural Audit and Rehabilitation of Building”
IRJET Journal
IRJET- Structural Audit and Rehabilitation of Building
IRJET- Structural Audit and Rehabilitation of Building
IRJET Journal
IRJET- Structural Audit and Rehabilitation of Building
IRJET- Structural Audit and Rehabilitation of Building
IRJET Journal
IRJET- Comparative Analysis for High Rise Building of Tunnel Formwork System ...
IRJET- Comparative Analysis for High Rise Building of Tunnel Formwork System ...
IRJET Journal
IRJET- Structural Audit of 30 Years Old Building with Structural Strengthening
IRJET- Structural Audit of 30 Years Old Building with Structural Strengthening
IRJET Journal
Structural Diagnosis, Repair and Retrofitting of RCC Structure
Structural Diagnosis, Repair and Retrofitting of RCC Structure
IRJET Journal
IRJET- Analysis and Design of 9 Storied RC Building using various Retrofittin...
IRJET- Analysis and Design of 9 Storied RC Building using various Retrofittin...
IRJET Journal
IRJET- Comparative Analysis of Aluminium Formwork Building and Conventional F...
IRJET- Comparative Analysis of Aluminium Formwork Building and Conventional F...
IRJET Journal
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET Journal
IRJET- Analysis, Design and Estimation of Multi- Storied Residential Buil...
IRJET- Analysis, Design and Estimation of Multi- Storied Residential Buil...
IRJET Journal
Condition Assessment and Evaluation of Concrete Structures by Advanced Non-de...
Condition Assessment and Evaluation of Concrete Structures by Advanced Non-de...
IRJET Journal
Life-Cycle Cost Analysis of Concrete Structures
Life-Cycle Cost Analysis of Concrete Structures
IRJET Journal
IRJET- Non Destructive Testing of Old R.C.C. Framed Structure
IRJET- Non Destructive Testing of Old R.C.C. Framed Structure
IRJET Journal
IRJET - Repair and Rehabilitation of Reinforced Concrete Bridge
IRJET - Repair and Rehabilitation of Reinforced Concrete Bridge
IRJET Journal
IRJET- Strengthening of New Building
IRJET- Strengthening of New Building
IRJET Journal
An Analytical and Experimental Investigation of Ultimate Load Carrying capaci...
An Analytical and Experimental Investigation of Ultimate Load Carrying capaci...
IRJET Journal
IRJET- A Case Study on Rehabilitation and Retrofitting of Cheetal Marriage Ac...
IRJET- A Case Study on Rehabilitation and Retrofitting of Cheetal Marriage Ac...
IRJET Journal
Similar to IRJET- Retrofitting of Reinforced Concrete Structures
(20)
IRJET- Review on Restrengthening of Existing R.C Structure with Considera...
IRJET- Review on Restrengthening of Existing R.C Structure with Considera...
IRJET- U-Boot Technology
IRJET- U-Boot Technology
A Review of Effective Use of Fischer Chemical for Rebaring in Existing Concre...
A Review of Effective Use of Fischer Chemical for Rebaring in Existing Concre...
“Structural Audit and Rehabilitation of Building”
“Structural Audit and Rehabilitation of Building”
IRJET- Structural Audit and Rehabilitation of Building
IRJET- Structural Audit and Rehabilitation of Building
IRJET- Structural Audit and Rehabilitation of Building
IRJET- Structural Audit and Rehabilitation of Building
IRJET- Comparative Analysis for High Rise Building of Tunnel Formwork System ...
IRJET- Comparative Analysis for High Rise Building of Tunnel Formwork System ...
IRJET- Structural Audit of 30 Years Old Building with Structural Strengthening
IRJET- Structural Audit of 30 Years Old Building with Structural Strengthening
Structural Diagnosis, Repair and Retrofitting of RCC Structure
Structural Diagnosis, Repair and Retrofitting of RCC Structure
IRJET- Analysis and Design of 9 Storied RC Building using various Retrofittin...
IRJET- Analysis and Design of 9 Storied RC Building using various Retrofittin...
IRJET- Comparative Analysis of Aluminium Formwork Building and Conventional F...
IRJET- Comparative Analysis of Aluminium Formwork Building and Conventional F...
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET- Analysis, Design and Estimation of Multi- Storied Residential Buil...
IRJET- Analysis, Design and Estimation of Multi- Storied Residential Buil...
Condition Assessment and Evaluation of Concrete Structures by Advanced Non-de...
Condition Assessment and Evaluation of Concrete Structures by Advanced Non-de...
Life-Cycle Cost Analysis of Concrete Structures
Life-Cycle Cost Analysis of Concrete Structures
IRJET- Non Destructive Testing of Old R.C.C. Framed Structure
IRJET- Non Destructive Testing of Old R.C.C. Framed Structure
IRJET - Repair and Rehabilitation of Reinforced Concrete Bridge
IRJET - Repair and Rehabilitation of Reinforced Concrete Bridge
IRJET- Strengthening of New Building
IRJET- Strengthening of New Building
An Analytical and Experimental Investigation of Ultimate Load Carrying capaci...
An Analytical and Experimental Investigation of Ultimate Load Carrying capaci...
IRJET- A Case Study on Rehabilitation and Retrofitting of Cheetal Marriage Ac...
IRJET- A Case Study on Rehabilitation and Retrofitting of Cheetal Marriage Ac...
More from IRJET Journal
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
IRJET Journal
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
IRJET Journal
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
IRJET Journal
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
IRJET Journal
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
IRJET Journal
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
IRJET Journal
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
IRJET Journal
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
IRJET Journal
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
IRJET Journal
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
IRJET Journal
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
IRJET Journal
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
IRJET Journal
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
IRJET Journal
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
IRJET Journal
React based fullstack edtech web application
React based fullstack edtech web application
IRJET Journal
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
IRJET Journal
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
IRJET Journal
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
IRJET Journal
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
IRJET Journal
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
IRJET Journal
More from IRJET Journal
(20)
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
React based fullstack edtech web application
React based fullstack edtech web application
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Recently uploaded
Online banking management system project.pdf
Online banking management system project.pdf
Kamal Acharya
Extrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
120cr0395
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
Prabhanshu Chaturvedi
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Dr.Costas Sachpazis
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
Asutosh Ranjan
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
rknatarajan
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
upamatechverse
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls in Nagpur High Profile
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
ranjana rawat
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
sanyuktamishra911
result management system report for college project
result management system report for college project
Tonystark477637
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
rakeshbaidya232001
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
rknatarajan
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
ranjana rawat
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
ranjana rawat
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur High Profile
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
Call Girls in Nagpur High Profile Call Girls
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
slot gacor bisa pakai pulsa
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
SIVASHANKAR N
Recently uploaded
(20)
Online banking management system project.pdf
Online banking management system project.pdf
Extrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
result management system report for college project
result management system report for college project
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
IRJET- Retrofitting of Reinforced Concrete Structures
1.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1594 Retrofitting of Reinforced Concrete Structures S. Karuppasamy1, K. Shriram2, S. Pradeep Kumar2, K. Vijayakumar2, D. Rohithbabu2 1Assistant Professor: Civil Engineering Department, Prathyusha Engineering College, Thiruvallur, Tamil Nadu 2U. G Student: Civil Engineering Department, Prathyusha Engineering College, Thiruvallur, Tamil Nadu ---------------------------------------------------------------------***---------------------------------------------------------------------- Abstract – The reinforced concrete structures should have satisfactory performance during earthquakes and other disasters. For this purpose they are being repaired or retrofitted. Repair canleadto increasedstiffness, strength, and failure deformation. . A large number of reinforced concrete structures located seismic prone areas are not capable of withstanding earthquake action according to the current codal provisions. Furthermore the seismic behavior of the existing buildings are affected due to design deficiency, construction deficiency, additional loads, additional performance demand, etc. Recent earthquakes have clearly demonstrated an urgentneed toupgradeandstrengthenthese seismically deficient structures. The retrofitting is one of the best options to make an existing inadequate building safe against future probable earthquake or other environmental forces. Retrofitting reduces the vulnerability of damage of an existing structure during a near future seismic activity. This project deals with the inspection and verification of performance of existing structures, selectionoftheretrofitting methods, choosing the best retrofitting materialavailableand execution for retrofitting. Testing is done for the reinforced concrete beams that are retrofitted by overlaying method using Carbon Fibre Reinforced Polymer (CFRP) to find their strengths and results are interpreted. Key Words: Seismic action, loads, Retrofitting, Overlaying method, Carbon Fibre Reinforced Polymer 1. INTRODUCTION Reinforced Cement Concrete structures are the most abundantly used construction technique in this world. They are often found to exhibit distress and suffer damage, even before their service period is over, due to several causes such as improper design, faulty construction, change of usage of the building, change in codal provisions, overloading, earthquakes, explosion, corrosion, wear and tear, flood, fire, etc. To meet up the requirements of advance infrastructure new innovative materials/ technologies in civil engineering industry has started to make its way. The structures are becoming old and they are in greater need for additional repairs. Retrofitting is defined as the process of modification of existing structures like buildings, bridges, heritage structures to make them more resistant to the seismic activity and other natural calamities. 1.1 Need for Retrofitting Retrofitting of structures like building, which includes rehabilitation, maintenance and strengthening of the structure, is not only a need in construction and management in urban areas, but alsoa problem whicharises to structural engineers in property managementdisciplines. It is not financially possible to replace every building that is weakened due to failure of themembers, natural disasters or other causes and therefore retrofitting will have an important role in the civil field. Thus this reconstruction method will provide us that extra lifespan for the building and prove beneficial. In retrofitting, the structure must be designed so it is in keeping with its purpose of use and is both safe and durable. 1.2 Benefits of Retrofitting Retrofitting is the seismic strengthening of existing damaged and undamaged structure. It will be an improvement over the original strength which may be insufficient for the building in the future seismic actions. Increasing the global capacity (strengthening). This is typically done by the addition of cross braces or new structural walls. Increasing the local capacity of structural elements. In retrofitting, the structure must be designed so it is in keeping with its purpose of use and is both safe and durable. There are considerable number of buildings that do not meet the requirement of current design standards. The serviceability of the structure will increase with retrofitting. 1.3. RETROFITTING METHODS There are several factors that govern the selection of the retrofitting methods like the existing concrete strength, accessibility to work areas, the extent of damage, cost, etc. Thus, selecting the right method will vary with each structure.
2.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1595 • Fibre Reinforced polymer(FRP) composites using Overlaying Method • External plate bonding • Near Surface Mounted FRP bars or Strips • External post-tensioning • Grouting • Epoxy Injection 1.4. MATERIALS FOR RETROFITTING The materials that are used for retrofitting have their own properties, advantages and disadvantages. These materials are retrofitted over the reinforced concrete elements and tested for their Young’s modulus, yield strength, tensile strength and strain. In this project CFRP and epoxy resin adhesive were used to retrofit the reinforced concrete structures. Some of the most commonly used materials are: • Ferrocement • Polymer Modified Concrete • Epoxy Resins • Carbon Fibre Reinforced Polymer(CFRP) 1.4.1CARBONFIBREREINFORCEDPOLYMER(CFRP) CFRPs exhibit several improved properties, such as high directional strength, higher stiffness, superior fatigue properties, corrosive resistance and suitable for complex designs. Tensile strength = 1700-3700 MPa Modulus of Elasticity = 120-580 GPa Density = 1800-2100 Kg/m3 Modulus of elasticity to density Ratio = 31-33 Strain at break = 0.5-1.9 Creep Rupture stress limit = 0.55 1.4.2 EPOXY RESINS Silicone is a non-corrosive neutral cure industrial grade silicone sealant which can be used to meet a variety of sealing and gasketing needs. It provides excellent adhesion, low odour, non-corrosive, UV- resistance, fast cure and remain flexible. Uncured specific gravity = 1.03 Setting time = 1 hour Full cure = 7 days Density = 0.8-1 Kg/m3 2. REVIEW OF LITERATURE Yasmeen Taleb Obaidat, Susanne Heyden, Ola Dahlblom (2010) [1] presented a finite element analysis which is validated against laboratory tests of eight beams. All beams had the same rectangular cross-section geometry and were loaded under four point bending, butdifferedinthelengthof the carbon fibre reinforced plastic (CFRP) plates. Linear elastic isotropic and orthotropic models were used for the CFRP and a perfect bond model and a cohesive bond model was used for the concrete–CFRP interface. Shibi Varghese, Binusha Majeed (2016) [2] on their paper have analysed the performance of retrofitting techniques and reviewed the materials properties and their performance. The test results of the FRP AND GFRP retrofitted beams were compared and studied. Soumya Gorai, P.R. Maiti [3] reviewed about the various techniques and advancements that are implemented for retrofitting of reinforced concrete structures. All the methods used are explained and the papers that were publishedonretrofitting were reviewed. Faisal M. Mukthar, Rayhan M. Faysal (2018)[4] published a paper on studying the FRP-Concrete Behaviour. The externally bonded FRP-Concrete behaviour is studied using five major approaches, namely, singleshear-laptests,double shear lap tests, bending type test, mixed mode-loading tests and tension pull-off tests and the resulting data was collected by using strain gauges. The literature about the various testing procedures of materials, reinforced concrete elements and bonding between the materials and concrete are studied.Thevarious methods of retrofitting techniques and their results are studied to have an overview of the retrofitting procedures that have been done in the past and to help with the improvement of those techniques in various aspects. 3. METHODOLOGY The following flowchart illustrates the methodology by which retrofitting is carried out in reinforced concrete structures. Chart-1: methodology
3.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1596 3.1 INSPECTION OF THE STRUCTURE The element at which the structure has weakened has to be analysed and then physical inspection must be carried out for the whole structure. The visibility of the cracks and deflections at the important joints and structural elements will give a rough idea for carrying out further tests. 3.2 NON-DESTRUCTIVE TESTING Since the structure is already weak and unstable destructive testing methods will not be suitable for it. Some of the basic and commonly used Non-Destructive tests are as follows: • Schmidt’s rebound hammer test • Ultrasonic Pulse velocity test 3.2.1 SCHMIDT’S REBOUND HAMMER TEST The rebound hammer is a surface hardness tester for which an empirical correlation has been established between strength and rebound number. The only known instrument to make use of the rebound principle for concrete testing is the Schmidt hammer, which weighs about 4 lb. (1.8 kg) and is suitablefor bothlaboratory and field work. It consists of a spring-controlled hammer mass that slides on a plunger within a tubular housing. The hammer is forced against the surface of the concrete by the spring and the distance of rebound is measured on a scale. The test surface can be horizontal, vertical or at any angle but the instrument must be calibrated in this position. Several readings are taken, well distributed and reproducible, the average representingthereboundnumber for the cylinder. This procedure is repeated with several cylinders, after which compressive strengths are obtained. TABLE 1: Rebound Hammer test 3.2.2 ULTRASONIC PULSE VELOCITY TEST The pulse velocity method is an ideal tool for establishing whether concrete is uniform. It can be used on both existing structures and those under construction. Usually, iflarge differences inpulse velocityare foundwithin a structure for no apparent reason, there is strong reason to presume that defective or deteriorated concrete is present. High pulse velocity readings are generally indicative of good quality concrete. A general relation betweenconcretequality and pulse velocity is given in Table 2. Fig-1: Methods of propagating ultrasonic pulses TABLE 2: Ultrasonic Pulse Velocity Test Based on these tests the concrete structure will be classified and the further process is done. 3.3 RETROFITTING USING CFRP WRAPPING The wrapping or overlaying method is chosen for the retrofitting of reinforced sample beam and carbon fibre reinforced polymer is used as the material for retrofit. Fig-2: Carbon Fibre Reinforced Polymer(CFRP) 3.3.1 SURFACE CLEANUP AND REPAIR Remove all contaminated area with debris, grease or oil, by grinding and repair cracks or damaged section by injecting AVERAGE REBOUND NUMBER QUALITY OF CONCRETE >40 VERY GOOD HARD LAYER 30 TO 40 GOOD LAYER 20 TO 30 FAIR <20 POOR CONCRETE 0 LAMINATED PULSE VELOCITY(Km/Sec) CONCRETE QUALITY (GRADING) ABOVE 4.5 EXCELLENT 3.5 TO 4.5 GOOD 3.0 TO 3.5 MEDIUM BELOW 3.0 DOUBTFUL
4.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1597 epoxy resin (Grind the corner to have R=30mm radius). The proper temperature in working space is between 10ºC and 35ºC. 3.3.2 REMOVING THE EXISTING PLASTERING The plastering is also removed before the actual surface is treated. Theyare removed until theactualcrackedelementis fully seen. The cracks are then tested and investigatedsothat the correct treatment can be done in order to cover the cracks and retrofit them using CFRP. 3.3.3 CRACK INJECTION Epoxy based grouting is preferred tocementdueto property of quick setting, very low shrinkage, excellentadhesion,high strength, low viscosity to penetrate even hair cracks and good resistance to most of the chemicals. Epoxy grouting is done based on the type of crack,widthand depth of crack in concrete structure. Groutingofwidecracks requires large quantity of grout materials. In such cases fillers are used to fill the cracks before epoxy grouting. Silicon four is one of the filler material used. The filler material to be used should be based on the manufacturers specification. Very low viscosity epoxy resin and hardener composition is used for injection grouting of cracks. Based on the width of crack, depth and extent of cracks and other relevant details, the viscosity of the resinhardenermix,theirproportions, pot life, application procedure etc. is selected in consultation with the manufacturer. Equipment Required for Epoxy Injection Grouting • Hole drilling equipment, pneumatic or electric based. • Pressure injection equipment of standard make with control valves and gauges. • Air compressor of capacity 3 to 4 cum/min. and pressure of 10 kg/cm2. • Polythene or metal pipe pieces 6 – 9mm diameter. • Polythene / plastic containers for mixing the epoxy formulation. • A portable generator. Then cracks in concrete is cut open into a ‘V’ groove about 10mm deep by mechanical or manual method. Loose materials are removed by using compressed air. The ‘V’ groove cut is fully sealed with epoxy mortar at least one day in advance before epoxy injection. Nails are driven into the cracks at 15 cm to 50cm intervals along the crack. Holes of 7 – 10 mm diameter is then drilled along the cracks and Copper or Aluminium or polythene pipe pieces of 6 – 9 mm diameter is fixed as grout nipples around the nails and allowed to rest on them. Epoxy formulation is injected from the bottom mostpipe. All other pipes, except the adjacent onesareblocked bywooden plugs. The injection is done using suitablenozzlesconnected to air compressors or by hand operated modified grease guns. Pressure of 3.5 to 7 kg /cm2 is normally used. As soon as the epoxy comes out from the adjacent open pipes, they are plugged and the pressure is increased to the desired level and maintained for 2 to 3 minutes. The injection nozzle is then withdrawn and the hole sealed with epoxy mortar. 3.3.4 PREPARATION OF CARBON FIBRE WRAPS • Primer Application: Apply primer a couple of times on the position of concrete surface which will attach the carbon fiber. (Standard amount of primer : 0.3kg/m2) • The Bent Surface Control Apply epoxy putty with spatula to step area which waviness is over than 1mm. • Top Coat Resin Application (1st) After drying primer, apply the top coat resin for adhesion evenly with a roller or a brush (standard amount : 0.5kg/m2) • Attaching Carbon Fiber Sheet Attach Carbon fiber sheet on a concrete structure and rub the surface a couple of times with roller or rubber scoop toward the fiber direction. Make sure no-air pocket inside the sheet. • Top Coat Resin Application (2nd) Apply top coat resin on the sheet surface andlet resinbe penetrated into sheet by rubbing a coupleoftimestothe fiber direction (standard amount of resin :0.3kg/m2).In case of adding more sheets, repeat steps. Fig-3: Beam Specimen After Retrofitting
5.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1598 3.3.5 INSTALLATION OF CARBON FIBRE WRAPS There are two methods by which the carbon fibers are wrapped or overlaid over a reinforced concrete structure. 3.3.5.1 WET-LAYING METHOD Wet lay-up is a molding process that combines layers of reinforced fiber material with liquid resin to create a high quality laminate. • Wet Lay-up Technique This process involves the positioning of reinforcement material into or against a mold in layers. These layers are then impregnated with a liquid resin system, either with a brush or roller, to ensure a good wet-out of the reinforcement material. The step is repeated until reinforcement thickness is achieved. Curing can be performedatroomtemperatureorunderheat, depending on the selection of the resin system. This can be accomplished with or without the use of a vacuum bagging process (recommended for a higher quality part). Benefits of Wet Lay-up • Easy processing • Low capital investment • Convenient for low-volume production 3.3.5.2 DRY-LAYING METHOD A dry carbon fiber sheet is laid over the part or mold and resin is applied by hand. The resin provides the stiffness for the dry sheet, and it is the bonding agent for a carbon fiber wrap. The second process is known as “pre-impregnated carbon-fiber lay-up.” This method uses fiber that is impregnated with resin. Pre-impregnation provides much better penetration of the resin and more uniform resin thickness than the wet lay-up process. The pre-impregnated roll is frozen by the vendor prior to delivery to prevent the resin from curing. The fiber is thawed at the lay-up site and hand laid over the part or mould. 3.4 TESTING OF BEAM SPECIMEN The beam specimen are of dimensions 1.50 x 0.10 x 0.15 (in meters). Control beams of these dimensions are tested and then compared with the beams that are wrapped using Carbon- Fibre-Reinforced Polymer. They are tested by using the load frame method. The testing is sameforall the beam specimens.First,thebeamsarecured and then they are tested by means of two point loading condition. The load is transmitted through aload celland the load is spread over two points. The beam is spread over two roller bearing at 150 mm from the end. Proving ring and deflectometers were used to measure the corresponding deflection values for the load provided. Fig-4: Testing Of Control Beam The wrapping of the beam can be done in any forms such as full-wrap, U-shaped wrap, Strip Wrapping, etc. in which U- shaped wrapping is being done. Fig-5: Testing of Retrofitted Beam Specimen 4. RESULTS The tests are done with proving ring to measuretheloadthat it resists and deflection gauge to measure the deflection occurred for the respective loads. The control beams are tested without retrofitting and the results are noted.
6.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1599 Chart -2: RCC Beam before retrofitting Then the same control beams are retrofitted using carbon fibre reinforced polymer and allowed to cure. Epoxy resin was used as the binding material between the concrete and the fibre. The curing period to attain its full strength is 24 hours. It will attain its initial strength with four hours after retrofitting. Then, the beam is tested and the results are taken. Chart -3: RCC Beam after retrofitting The results show that the load resisted by the beams after retrofitting are more than that of the control beams. Chart -4: Load resisted by the beam (Kn) The deflection occurred due to the corresponding loads are also lesser in the retrofitted beams than the control beams. Chart -5: Deflection Comparison(mm) 5. CONCLUSIONS The process of retrofitting a reinforcedconcretestructureis elaborated and the experimental investigation of the testing beam before and after retrofitting are studied. The results indicate the following conclusions: • The deflection of the beam is reduced when it is wrapped using carbon fibre and with full wrapping technique it will provide more strength. • The retrofitted beams havegreaterflexural strength and ultimate load capacity after external wrapping. • The carbon fibre reinforced polymer remained intact even after the failure of beam. Overlaying or wrapping techniqueisthe easiestand quickest way to retrofit a structure and it provides greater strength than other methods. Retrofitting of structures will not only retain the initial strength lost but will also help in increasing it twice-fold. It will increase the building’s serviceabilityand safety against seismic action. Thus, retrofitting will be helpful in rehabilitation and strengthening of reinforced concrete structures. REFERENCES [1] Yasmeen TalebObaidat,SusanneHeyden,Ola Dahlblom, The effect of CFRP and CFRP/concrete interface models when modelling retrofitted RC beams with FEM (2010) DOI: 10.1016/j.compstruct.2009.11.008 [2] Prof. Shibi Varghese, Binusha Majeed, Habeebullah R,Mitin Mathew, Shabida K.K , Studyontheperformance of retrofitting techniques in RCC Beams e-ISSN: 2395 - 0056 p-ISSN: 2395-0072 (June 2016) pp.2073-2076 [3] Soumya Gorai, P.R. Maiti, Advanced Retrofitting techniques for Reinforced Concrete Structures: A State Of an art review, (March-May 2016) Vol.5, No.1 [4] Faisal M. Mukthar, Rayhan M. Faysal, A Review of test methods for studying the FRP-ConcreteInterfacial Bond Behaviour(February2018)https://doi.org/10.1016/j.co nbuildmat.2018.02.163
Download now