UBS 1.04 Operating instructions
(R)
(B)
LN Ls1 2
UNIVERSAL RELAY SWITCH
II
Revision History
Rev.
Doc.
Data Revisor Pag. Descrizione
1 24/06/2014 RC 6,7,8
,12
Minor updates regarding text
10 Text “32 (0x1E)” changed in “32 (0x20)”
Text “33 (0x1F)” changed in “33 (0x21)”
Text “34 (0x1E)” changed in “34 (0x22)”
Text “35 (0x1F)” changed in “35 (0x23)”
Text “36 (0x1E)” changed in “36 (0x24)”
Text “37 (0x1F)” changed in “37 (0x25)”
11 Text “0 – TIMER ENABLED” changed in “0 – TIMER DISABLED”
Text “1 – TIMER DISABLED” changed in “1 – TIMER ENABLED”
12 Removed row “IGNORE” from first the table
1
Device description
Line Phase connection terminals
Null Neutral connection terminals
Relay Contact Latching Relay Contacts
Line signal
This terminal gets a phase signal that drives the relay. The system recognises
the status change of this connection (switch from 0 to phase voltage and vice
versa)
Reset Pressing this button the system will restart
Push Button
Service button: 1 or 3 clicks enters Learning Mode, with 6 clicks the System is
reset to factory settings
Technical Specification
Power supply 230 VAC±10% 50/60 Hz
Maximum Load
2500 VA – 250 VAC - 10A resistive load in AC
300 VA – 30 VDC – 10A resistive load in DC
System temperature limitation 105 °C
Work temperature 0 – 40° C
Radio protocol Z-Wave 868,4 MHz
Range up to 60 m outdoors, up to 30 m indoors
Dimensions (HxWxD) 43x43x17 mm
Consumption <210 mW
Actuator element Latching relay
Conformity CE, RoHs
Push Button
Reset
LineNull Relay
Contact
Line signal
(R)
(B)
LN Ls1 2
2
Introduction
WiDom Universal Relay Switch is a Z-Wave certified “in wall device”.
The device is based on the use of a latching relay that is combined with an innovative design and effective
implementation to ensure extremely low energy consumption.
WiDom Universal Relay Switch is designed for being installed in junction boxes, flush mount boxes and near
lights. WiDom Universal Relay Switch is an ONOFF device and can be used as both a local and remote
switch. It supports two wire connections, which allows it to be installed into any existing system without the
need to change the wiring.
At the same time, it is completely configurable so that it can adapt to the most varied needs while also being
ready to be used without needing additional configurations in order to operate.
Thanks to the framework developed by WiDom, the various types of “events” on the “External Switch” can be
recognised and associated to actions to be performed on the device, andor on any associated devices andor
on all devices on the network. The events that the system recognises are the number of “clicks” or hold on the
External Switch.
Although Z-Wave is quite new technology, it has already become recognizable and officially binding standard,
similarly to Wi-Fi. Many manufacturers in various industries offer solutions based on Z-Wave technology,
guaranteeing their compatibility. This means that the system is open and it may be extended in the future.
External Switch: Any switch, button or traditional wall control connected to the device in order to turn it
on or off.
Events: The actions performed on the external Switch: Clicks or Hold.
Click: If the external switch is a button (when pressed it returns to the start position by itself), a click
means pressing and then releasing it. If the external switch is a bistable one (after being pressed it does
not return to the original position), a single click means one single flip of the switch.
Hold: This applies only to buttons that are normally open and that are identified as such when the
pressure phase lasts at least 1,5 seconds.
Device in ONOFF status refers to the fact that the latching relay contact is in the OpenClose position.
3
Installation
WARNING: WiDom Universal Relay Switch must be installed by a certified electrician in compliance
with the safety requirements set forth in national law regulations.
DANGER: WiDom Universal Relay Switch must be connected to 240VAC. Before performing any
installation operations, make sure the main switch on the meter is set to OFF.
DANGER: Any procedure that calls for the use of the (R) and (B) service buttons is related only to the
installation phase and is to be considered a service procedure that must be performed by qualified
personnel. This operation must be performed with all necessary precautions for operating in areas with a single
level of insulation.
WARNING: Do not connect loads that exceed the maximum load permitted by the relay contacts. In the
case of greater loads, WiDom Universal Relay Switch may be used to control an external relay or a
contactor. For non-resistive loads, the maximum load must be appropriately reduced.
WARNING: All connections must be performed according to the electrical diagrams provided
WiDom Universal Relay Switch Activation
1) Make sure the mains switch is set to the OFF position
2) Connect the device based on the diagrams provided
3) Close the electrical box that contains the device
4) Turn the system back on
5) Include the device in the Z-Wave network
TIP: The antenna must not be shortened, removed or modified. To ensure maximum
efficiency, it must be installed as shown. Metal equipment near the antenna can
negatively affect reception. Each WiDom device is a node in a mesh network. If there are
metal obstacles, the obstacle can often be overcome with a further triangulation node.
(R)
(B)
LN Ls1 2
4
Three-Wire connection
The device must be supplied by phase and neutral. The third control wire carries a phase signal on the Ls
terminal controlled by the external switch.
Diagram A Diagram B
N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls)
Control contact
N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls)
Control contact
*Maximum wire length<15m
INFO: The external switch can be either a bistable, a normally opened button or any sequence of SPDT
- DPDT (Fig.AB.1) or buttons (Fig.AB.2).
Fig.AB.1 Fig.AB.2
INFO: If using a secondary load supply system, it must be connected as in diagram B. The supply voltage
can be either AC or DC within the limits permitted by the relay contact, up to 250 V in AC and up to 30 V
in DC.
WARNING: The line connected to the relay contacts must be suitably protected from short circuits and
overloads connected to a possible failure of the connected load
L
N
(R)
(B)
LN Ls1 2
 Bistable switch
 Normally Opened
monostable switch
Secondary
Power Supply
System
L
N
(R)
(B)
LN Ls1 2
 Bistable switch
 Normally Opened
monostable switch
L Ls
Ls
5
Two wire connection - AC Sensing
With this type of connection, the momentary interruption of the phase is interpreted by the system as a load
switching command. This configuration is suitable for controlling existing lighting system.
Diagram C Diagram D
N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls)
Control contact
N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls)
Control contact
*Maximum wire length<15m
INFO: The external switch can be a normally closed button as well as any series, as shown in figure
CD.1.
Fig.CD.1 Fig.CD.2
TIP: In this mode, the device can be installed near the light to be controlled and the existing switch is
replaced with a normally closed button. For a light controlled from several points, all of the switches
should be replaced with normally closed buttons. Please note that in this case another connection that may
work is shown in figure CD.2 where the necessary modified connection for just one of the switches is
represented.
TIP: In order to control a neon tube with a traditional ballast and a starter and in general with non-pure
resistive loads or with long wire connections a WiDom Switch Helper should be connected in parallel to
the load as shown in diagram C.
INFO: If using a secondary load supply system, it must be connected as in diagram D. The supply
voltage can be either AC or DC within the limits permitted by the relay contact, up to 250 V in AC and
up to 30 V in DC.
WARNING: The line connected to the relay contacts must be suitably protected from short circuits and
overloads connected to a possible failure of the connected load.
L
N
(R)
(B)
LN Ls1 2
Optional:
WiDom
Switch Helper
 Normally Closed
monostable switch
Secondary
Power Supply
System
L
N
(R)
(B)
LN Ls1 2
 Normally Closed
monostable switch
LsL
L
6
Reset to the factory settings
The device can be reset to the original factory settings using one of the following methods:
Method 1: Remove the device from the Z-Wave network
Method 2: Six consecutive clicks on button (B)
Method 3: Set parameter 61 to value 0 - FACTORY RESET (see paragraph 0).
INFO: If the reset is performed while the device is still part of a network, it notifies the other devices that
it has been removed (Device Reset Locally Notification). If WiDom Universal Relay Switch receives a
removal notification from another device, it will delete the removed device from its own associations.
Including the device into an existing Z-Wave network
WiDom Universal Relay Switch can be included and operated in any Z-Wave network with other Z-Wave
certified devices from any other manufacturers. As constantly powered node WiDom Universal Relay Switch
will act as repeater regardless of the vendor in order to increase reliability of the network.
The device supports both the Network Wide Inclusion mechanism (which offers the ability to be included in
a network even if the device is not in the direct range of the controller) and Normal Inclusion.
By default, if the device is not included in any network, as soon as it is powered the Network Wide Inclusion
procedure starts and lasts for about 1 minute. The procedure can be reactivated at the next device restart or
by pressing the (R) button.
If the used controller does not support the Network Wide Inclusion functionality, the device may be included
in the network through Normal Inclusion by pressing the (B) button once or three times or alternatively by
pressing the external switch once.
INFO: During the inclusion procedure activated by a single click on the external switch, the system also
automatically determines the switch type (See parameter No. 62).
Excluding the device from a Z-Wave network
Only a controller can remove a device from the network. WiDom Universal Relay Switch is compatible with all
Z-Wave certified controllers. After the exclusion function has been activated from the controller, the device can
be removed, putting it in Learning Mode by pressing the (B) button once or three times or more conveniently
by using the external switch after having enabled the learning mode activation from external switch (see
parameter N°65).
Request network update
If there is a SUC (Static Update Controller) or SIS (SUC ID Server) in the network, a network update can be
requested by pressing the external switch four times.
Associations
WiDom Universal Relay Switch can control other devices like other relays or dimmers. WiDom Universal Relay
Switch supports 5 association groups:
Group 1: devices that will be notified of changes in its status
Group 2: devices that will be controlled by a single click on the external switch
Group 3: devices that will be controlled by a double click on the external switch
Group 4: devices that will be controlled by a triple click on the external switch
Group 5: devices that will be controlled by hold on the external switch
TIP: WiDom Universal Relay Switch can control up to 16 devices for each group. To avoid network
delays, we recommend limiting the amount of associated devices to no more than 5 per group.
7
Controlling the device with an external switch
With WiDom devices, the normal switches/buttons found in a traditional electrical system can become
intelligent control systems.
WiDom Framework recognises the number of clicks or hold event on the external switch and can be configured
to perform different actions based on the identified event.
Controlling the device via the Z-Wave network
All Z-Wave controllers can control the device using the Basic Set command.
The behaviour of the device based on its status and on the commands received from the network can also be
configured.
Alarms management
WiDom Universal Relay Switch can also be configured to react to alarm notifications from sensors on the
network. WiDom Universal Relay Switch recognises and complies with Notification V3 Report frame alarm
notifications.
INFO: By default, WiDom Universal Relay Switch reacts to smoke, heat, water and home security alarms
generated by others Z-Wave sensors in the system. The reaction type: ON, OFF or FLASHING can be
configured as needed.
Switch ALL ONOFF
By default, WiDom Universal Relay Switch accepts Switch All ONOFF commands.
Timer option
WiDom Universal Relay Switch has a built-in configurable timer for programmed switch-off.
Troubleshooting
By pressing the (B) and (R) buttons at the same time and then releasing (R), the system starts a check
procedure that can produce one of the following results:
1. If the device is included in a network, it switches from ON to OFF repeatedly with equal ON and OFF
times of 2 seconds each.
2. If the device is not included in a network, it switches from ON to OFF repeatedly with an ON time of 2
seconds and an OFF time of 6 seconds.
INFO: The procedure described lasts until the (R) button is pressed again.
Configurations
Controlling the device by external switch
Clicks on the external switch turn the connected load on or off depending on the initial status, on the number
of clicks and on the device configuration. The actions that will be performed on the associated devices and on
all other devices on the network can also be configured.
INFO: As soon as the click recognition process has completed, the device will be set to the desired
status, any switch all onoff actions will be performed and the associated devices will be controlled.
8
Device status
The final device status will be determined by the initial status, number of clicks or hold. The following
configurations can be used to configure parameters 1 through 4.
Value Initial status Final status
1 – TOGGLE
ON OFF
OFF ON
2 – ON
ON If the initial status is OFF, the system will switch ON; otherwise, it
maintains its status (ON).OFF
3 – OFF
ON If the initial status is ON, the system will switch OFF; otherwise, it
maintains its status (OFF).OFF
4 – IGNORE
ON The device maintains its initial status and if the programmed switch-
off timer is active, it is restarted.OFF
Parameter No. 1: Device status when the external switch receives 1 click (1 byte).
Default value: 1 – TOGGLE
Parameter No. 2: Device status when the external switch receives 2 clicks (1 byte).
Default value: 1 – TOGGLE
Parameter No. 3: Device status when the external switch receives 3 clicks (1 byte).
Default value: 1 – TOGGLE
Parameter No. 4: Device status when the external switch is held down (1 byte) - This parameter only
takes effect if a normally open button is connected.
Default value: 1 – TOGGLE
WARNING: Careless usage of the configuration parameters can create inconsistencies.
Controlling the associated devices
The actions performed on associated devices in terms of Basic Set will be determined by the initial status,
number of clicks or hold. The following configurations can be used to configure parameters 5 through 8.
Configuration
Initial device
status
Action performed on the associated device
1 – TOGGLE
ON Basic Set OFF_LEVEL
OFF Basic Set ON_LEVEL
2 – IGNORE IF ON
ON No action
OFF Basic Set ON_LEVEL
3 – IGNORE IF OFF
ON Basic Set OFF_LEVEL
OFF No action
4 – TOGGLE
ASSOCIATED
ON The status of each associated device is requested with the Basic
Get command. If it is OFF, the Basic Set ON command is sent,
otherwise the Basic Set OFF command is sent.OFF
5 – SET AS INITIAL
STATUS VALUE
ON Basic Set ON_LEVEL
OFF Basic Set OFF_LEVEL
6 – IGNORE
ON
No action
OFF
TIP: TOGGLE ASSOCIATED: This configuration is useful for configuring the device as a remote switch.
We recommend this configuration for controlling a single remote device. When using this option, in order
to avoid any inconsistent result, we recommend keeping the Switch All actions disabled.
9
Parameter No. 5: Action on the associated devices when the external switch receives 1 click (1 byte).
Default value: 1 – TOGGLE
Parameter No. 6: Action on the associated devices when the external switch receives 2 clicks (1
byte).
Default value: 1 – TOGGLE
Parameter No. 7: Action on the associated devices when the external switch receives 3 clicks (1
byte).
Default value: 6 – IGNORE
Parameter No. 8: Action on the associated devices when the external switch is held down (1 byte).
Default value: 1 – TOGGLE
Switch ALL functionality
The actions performed on all network devices in terms of Switch ALL will be determined by the initial status,
number of clicks or hold. If there are associated devices and there are control actions set for these devices,
the Switch ALL actions are performed first.
The following configurations can be used to configure parameters 9 through 12.
Value
Initial device
status
Action performed on all devices in the network
1 – TOGGLE
ON SWITCH ALL OFF
OFF SWITCH ALL ON
2 – IGNORE IF ON
ON No action
OFF SWITCH ALL ON
3 – IGNORE IF OFF
ON SWITCH ALL OFF
OFF No action
4 – SET AS INITIAL
STATUS VALUE
ON SWITCH ALL ON
OFF SWITCH ALL OFF
5 – IGNORE
ON
No action
OFF
Parameter No. 9: Action performed on all network devices when the external switch receives 1 click
(1 byte). Default value: 5 – IGNORE
Parameter No. 10 (0xA): Action performed on all network devices when the external switch receives 2
clicks (1 byte). Default value: 5 – IGNORE
Parameter No. 11 (0xB): Action performed on all network devices when the external switch receives 3
clicks (1 byte). Default value: 5 – IGNORE
Parameter No. 12 (0xC): Action performed on all network devices when the external switch is held
down (1 byte). Default value: 5 – IGNORE
10
Controlling the device by Z-Wave Network
The device final status reached by the device when it receives a Basic Set command from the Z-Wave
network.
Parameter No. 20 (0x14): Device status upon receipt of a Basic Set (1 byte)
Value
Command
received
Final status
1 – HOW RECEIVED
(Default value)
ON ON
OFF OFF
2 – IGNORE IF ON
ON Maintains the initial status
OFF OFF
3 – IGNORE IF OFF
ON ON
OFF Maintains the initial status
4 - IGNORE
ON Maintains the initial status and, if the programmed switch-off timer
is active, it is restarted.OFF
Setting ON_LEVEL and OFF_LEVEL
Defines the values associated to the ON_LEVEL and OFF_LEVEL parameters used in the Basic Set
commands. The following values can be used to configure parameters 30 through 37. From: 0 (OFF) to 255
(ON)
Parameter No. 30 (0x1E): ON_LEVEL value used for devices belonging to Group 2 (1 Click association
group) (1 byte).
Default value 255 – ON
Parameter No. 31 (0x1F): OFF_LEVEL value used for devices belonging to Group 2 (1 Click association
group) (1 byte).
Default value 0 – OFF
Parameter No. 32 (0x20): ON_LEVEL value used for devices belonging to Group 3 (2 Click association
group) (1 byte).
Default value 255 – ON
Parameter No. 33 (0x21): OFF_LEVEL value used for devices belonging to Group 3 (2 Click association
group) (1 byte).
Default value 0 – OFF
Parameter No. 34 (0x22): ON_LEVEL value used for devices belonging to Group 4 (3 Click association
group) (1 byte).
Default value 255 – ON
Parameter No. 35 (0x23): OFF_LEVEL value used for devices belonging to Group 4 (3 Click association
group) (1 byte).
Default value 0 – OFF
Parameter No. 36 (0x24): ON_LEVEL value used for devices belonging to Group 5 (Hold association
group) (1 byte).
Default value 255 – ON
Parameter No. 37 (0x25): OFF_LEVEL value used for devices belonging to Group 5 (Hold association
group) (1 byte).
Default value 0 – OFF
11
Timer Option
Enabling the timer for relay switch-off
The switch-off timer can be associated with any click or hold event. When the timer is enabled for the specific
event that generated the ON status, the device will go into the OFF status after the period of time defined in
parameter No. 45. The following configuration values can be used for parameters 40 through 44.
0 – TIMER DISABLED
1 – TIMER ENABLED
Parameter No. 40 (0x28): Timer associated with the 1 click event on the external switch (1 byte) -
Enables the switch-off timer if the device switches to ON following a single click on the external switch.
Default value: 0 – TIMER DISABLED
Parameter No. 41 (0x29): Timer associated with the 2 click event on the external switch (1 byte) -
Enables the switch-off timer if the device switches to ON following a double click on the external switch.
Default value: 0 – TIMER DISABLED
Parameter No. 42 (0x2A): Timer associated with the 3 click event on the external switch (1 byte) -
Enables the switch-off timer if the device switches to ON following a triple click on the external switch.
Default value: 0 – TIMER DISABLED
Parameter No. 43 (0x2B): Timer associated with the hold event on the external switch (1 byte) -
Enables the switch-off timer if the device switches to ON following hold on the external switch. Default value:
0 – TIMER DISABLED
Parameter No. 44 (0x2C): Timer associated with the reception of a Basic Set command (1 byte) -
Enables the switch-off timer if the device switches to ON following reception of a single click Basic Set
command.
Default value: 0 – TIMER DISABLED
Parameter No. 45 (0x2D): Switch-off timer (2 bytes) Defines the amount of time before the switch-off timer
takes place Time in seconds (1 – 3600);
Default value 600 (0x258), 10 minutes.
Parameter No. 46 (0x2E): Switch-off timer validity (1 byte) - Defines the system behaviour if an event
requests a status change for the device and the timer for the programmed switch-off timer was started by a
previous event.
Configuration Device reaction
0 - CANCEL
The switch-off timer is cancelled and the device maintains the last status
reached. If the new status is ON and the event that generated it is
associated with the timer, it is restarted.
1 - MAINTAIN
Default value
The switch-off timer is maintained
Manage Alarms
WiDom devices can react to alarms received. The system recognises alarm messages (version 3 of Alarm
Command Class). By default, all alarms are ignored except for those defined in the following table:
Alarm Alarm or Notification Type Event Event Parameters
Smoke Alarm, CO, CO2 0x01 – 0x02 – 0x03 ANY ANY
Heat Alarm 0x04 ANY ANY
Water Alarm 0x05 ANY ANY
Home Security 0x07 ANY ANY
12
The way the device reacts when it receives an alarm can be customised using parameters 50 through 53.
Configuration Device reaction
1 – ON The device status switches to ON
2 – OFF The device status switches to OFF
3 – FLASH
The device switches from ON to OFF with a frequency and duration that can be
customised using parameters 54, 55 and 56.
4- IGNORE The alarm will be ignored
Parameter No. 50 (0x32): Smoke Alarm, CO, CO2 Action (1 byte) - Defines how the device reacts when it
receives one of the following types of alarms: smoke, CO or CO2.
Default value: 1 – ON
Parameter No. 51(0x33): Heat Alarm (1 byte) - Defines how the device reacts when it receives Heat Alarm.
Default value: 1 – ON
Parameter No. 52(0x34): Water Alarm (1 byte) - Defines how the device reacts when it receives Water
Alarm.
Default value: 2 – OFF
Parameter No. 53 (0x35): Home Security (1 byte) - Defines how the device reacts when it receives Home
Security alarm.
Default value: 3 – FLASH
Parameter No. 54 (0x36): ON time during flashing (1 byte) Defines the number of seconds for the ON
status during flashing - (from 1 to 255).
Default value: 5 seconds
Parameter No. 55 (0x37): OFF time during flashing (1 byte) Defines the number of seconds for the OFF
status during flashing - (from 1 to 255).
Default value: 5 seconds
Parameter No. 56 (0x38): Duration of flashing phase (1 byte) - Defines the time in minutes from the last
receipt of the last alarm message received - (from 1 to 255).
Default value: 10 minutes
Other configuration parameters
Parameter No. 60 (0x3C): Startup status (1 byte) - Defines the status of the device after a restart following
a reset or black out.
Configuration Device reaction
1 – ON Device ON
2 – OFF Device OFF
3 – PREVIOUS STATUS
(Default value)
Status before the restart
Parameter No. 61 (0x3D): Configuration reset (1 byte) Defines which parameters must be reset to defaults.
Configuration Device reaction
0 – FACTORY RESET The device is reset to the original factory settings.
1 – RESET ASSOCIATIONS All associations and only the associations are reset
2 – RESET CONFIGURATIONS
The associations are maintained while all of the other configuration
parameters are reset to the original factory settings except for this
specific configuration.
4 – IGNORE
(Default value)
No action is performed
Parameter No. 62 (0x3E): Type of external switch (1 byte) - Defines the type of external switch connected
to the device.
13
Configuration Device reaction
0 – IGNORE
The actions on the external switch are ignored. In this mode, the
device can only be controlled via the network.
1 – BUTTON The external switch is a normally open button
2 – BISTABLE SWITCH The external switch is a traditional switch
3 – AC SENSING
The external switch is a normally closed button connected as shown
in diagrams C and D
4 – AUTOMATIC RECOGNITION
(Default value)
After the first single click on the external switch, the system
automatically determines the type of external switch used and
accordingly sets the parameter with the new value.
Parameter No. 63 (0x3F): Sensitivity (1 byte) - Sets the level of sensitivity associated with the AC SENSING
configuration.The value can be set between 0 (High sensitivity) and 255 (Low sensitivity).
Default Value: 9
Parameter No. 64 (0x41): Load protection (2 bytes) Defines the minimum amount of time in which the
switch cannot be flipped twice in succession. Time in seconds (1 – 3600).
Default value: 0
INFO: Some types of loads require a rest period between switch-off and subsequent switch-on. This
parameter is for setting this time. If this parameter is set and the load is off, when the device receives a
switch-on command, it will be performed as soon as the protection time has been reached.
Parameter No. 65 (0x40): Learn Mode (1 byte) - This defines the sequence of clicks on the external switch
to associate to Learning Mode.
Configuration Device reaction
0 – DISABLED
(Default value)
Learning mode cannot be activated from the external switch
1 – 1 CLICK Learning mode is activated by 1 click on the external switch
2 – 2 CLICKS Learning mode is activated by 2 clicks on the external switch
3 – 3 CLICKS Learning mode is activated by 3 clicks on the external switch
INFO: When Learning mode is associated to a click event any configurations related to the associated
devices and Switch All commands related to the same event are ignored. After the learning mode has
been associated to a click event this configuration is honoured for a single event. After that event the Learning
mode parameter will be reset to the default value (0 – DISABLED).
Compliance with directives
WiDom devices are built in compliance with directives LVD 2006/95/EC, EMC 2004/108/CE and R&TTE
Widom shall not be held responsible for any damage caused by these devices if they are used in a manner
that is not compliant with the instructions in this manual. WiDom reserves the right to make any changes to
the product that it considers necessary or useful without jeopardising its primary features.
Warranty
This warranty is provided by WiDom srl (hereinafter “WiDom”) based in Quartu S.Elena 09045 (CA), Italy (VAT number
03452490927).
WiDom warrants to the original purchaser (hereinafter “Customer”) that the device sold under this agreement (hereinafter
“Device”) is free from defects in parts and workmanship under normal use for 12 months from date of purchase (“Warranty
Period”).
The original purchase invoice or sales receipt, showing the date of purchase is the proof of date of purchase by the Customer.
14
If a Device, sold by WiDom to the Customer, has manufacturing defects or in any case of alleged lack of conformity, the
Customer shall send within thirty (30) days from the day in which he discovers such defects, a claim form by using our web
site: (www.widom.it) informing WiDom on the full name of the Customer, the nature of the defects and the date in which the
Devices has been purchased.
Warranty Claims received after the expiration of the Warranty Period shall not be considered valid.
Once WiDom, receives the Warranty Claim, it shall inform the Customer by e-mail or letter, if the Warranty is applicable and
the address where the Device shall be sent in order to verify the defects (if any). Customer must prepay shipping and
transportation charges as indicated by WiDom. The Device shall be sent by the Customer to WiDom at its own costs and
expenses, by express courier or hand delivered, and with the original packaging, the supplied accessories (if any) and
documents proving date of purchase. WiDom shall then inform the Customer about the defects and on its repair or replacement
(where applicable). Should WiDom not evidence defects on the Device, the Device shall be returned to the Customer.
Should WiDom notices the defects, and this warranty is applicable, it will remove, at its sole discretion, any defect, free of
charge, by repairing any defective components of the Device with new or regenerated components or by replacing the Device.
The Warranty Period of the replaced or repaired Device shall not be extended.
WiDom will ship the repaired or a replaced Device to Customer freight prepaid.
WiDom will not be liable for damages to property caused by faulty device. WiDom will not be liable for indirect, incidental,
special, consequential or punitive damages, or for any damage, including, inter alia, loss of profits, savings, data, loss of
benefits, claims by third parties and any property damage or personal injuries arising from or related to the use of the Device.
If the Device cannot be replaced with another of the same type (e.g. the Device is no longer in production or no longer available
for selling in the Customer’s country), it may be replaced with a different one having similar technical specifications to the
faulty one. Such replacement shall be considered as a total fulfilment of WiDom’s obligations.
Warranty exclusion
- defects caused by normal wear of parts or especially subject to wear, such as parts that require periodic replacement during
the normal operation of the system (eg. Batteries);
- splits, cracks, scratches, dents, scratched or discolored surfaces and parts, breakage of plastic parts and in general of any
other cosmetic damage;
- damages resulting from use of the system other than that provided, including but not limited to the failure to follow
instructions contained in the operating manual;
- damages caused by accident, abuse, misuse, dirt, viruses, liquid contact, fire, earthquake, improper or inadequate
maintenance or calibration, negligence or other external causes;
- environmental damage and / or defects caused by smoke, dust, dirt, soot, or other external influences;
- damages caused by modifications and alterations in the functionality or features without the written permission of WiDom;
- damages resulting from transportation or inadequate packaging when returning the product to a WiDom or to an authorize
service center;
- defects caused by force majeure events such as lightning, floods, fires, incorrect voltage, improper ventilation;
- damages caused by malfunctioning software, computer virus attack, or by failure to update the software as recommended
by WiDom;
- damages resulting from surges in the power and/or telecommunication network, improper connection to the grid in a manner
inconsistent with the operating manual, or from connecting other devices not recommended by WiDom;
- damages caused by operating or storing the device in extremely adverse conditions, i.e. high humidity, dust, too low (freezing)
or too high ambient temperature;
- products whose serial number has been removed, damaged or rendered illegible;
- expiration of the Warranty Period.
If a defect is not covered by the Warranty, WiDom will inform the Customer about the extra expenses for the repair or
replacement.
This warranty may be subject to changes. Please check at: www.widom.it the newest warranty claim procedure.
This guarantee shall not exclude, limit or suspend the Customer rights when the provided product is inconsistent with the
purchase agreement.
15
© All rights reserved. WiDom is a trademark of WiDom srl. All other brand names, product names, or trademarks belong to
their respective owners. WiDom reserves the right to change product features and specifications at any time without notice,
and is not responsible for typographical or graphical errors that may appear in this document.
Printed in Italy on low-impact recyclable paper.

More Related Content

What's hot

Aeon labs zw130 wall mote quad instructions
Aeon labs zw130 wall mote quad instructionsAeon labs zw130 wall mote quad instructions
Aeon labs zw130 wall mote quad instructionsDomotica daVinci
 
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_engQubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_engDomotica daVinci
 
Manual aeon labs heavy duty smart switch gen5
Manual   aeon labs heavy duty smart switch gen5Manual   aeon labs heavy duty smart switch gen5
Manual aeon labs heavy duty smart switch gen5Domotica daVinci
 
Qubino flush 1D relay user manual
Qubino flush 1D relay user manualQubino flush 1D relay user manual
Qubino flush 1D relay user manualDomotica daVinci
 
Universal Dimmer 250W Z-Wave+ Fibaro Manual
Universal Dimmer 250W  Z-Wave+ Fibaro ManualUniversal Dimmer 250W  Z-Wave+ Fibaro Manual
Universal Dimmer 250W Z-Wave+ Fibaro ManualDomotica daVinci
 
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
wiDom Smart Roller Shutter Z-Wave Plus Module ManualwiDom Smart Roller Shutter Z-Wave Plus Module Manual
wiDom Smart Roller Shutter Z-Wave Plus Module ManualDomotica daVinci
 
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual englishIn-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual englishDomotica daVinci
 
Fibaro RGBW controller manual
Fibaro RGBW controller manual Fibaro RGBW controller manual
Fibaro RGBW controller manual Domotica daVinci
 
wiDom Smart dry contact module Z-Wave Plus Manual
wiDom Smart dry contact module Z-Wave Plus ManualwiDom Smart dry contact module Z-Wave Plus Manual
wiDom Smart dry contact module Z-Wave Plus ManualDomotica daVinci
 
Fibaro Motion Multisensor Manual
Fibaro Motion Multisensor ManualFibaro Motion Multisensor Manual
Fibaro Motion Multisensor ManualDomotica daVinci
 
3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manual
3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manual3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manual
3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manualDomotica daVinci
 

What's hot (20)

Aeon labs zw130 wall mote quad instructions
Aeon labs zw130 wall mote quad instructionsAeon labs zw130 wall mote quad instructions
Aeon labs zw130 wall mote quad instructions
 
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_engQubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
 
MCOHOME 1 button
MCOHOME 1 buttonMCOHOME 1 button
MCOHOME 1 button
 
Manual aeon labs heavy duty smart switch gen5
Manual   aeon labs heavy duty smart switch gen5Manual   aeon labs heavy duty smart switch gen5
Manual aeon labs heavy duty smart switch gen5
 
Remotec ZXT120 manual
Remotec ZXT120 manualRemotec ZXT120 manual
Remotec ZXT120 manual
 
Qubino flush 1D relay user manual
Qubino flush 1D relay user manualQubino flush 1D relay user manual
Qubino flush 1D relay user manual
 
Qubino dimmer manual
Qubino dimmer manualQubino dimmer manual
Qubino dimmer manual
 
Manual Zipato PAB01
Manual Zipato PAB01Manual Zipato PAB01
Manual Zipato PAB01
 
Universal Dimmer 250W Z-Wave+ Fibaro Manual
Universal Dimmer 250W  Z-Wave+ Fibaro ManualUniversal Dimmer 250W  Z-Wave+ Fibaro Manual
Universal Dimmer 250W Z-Wave+ Fibaro Manual
 
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
wiDom Smart Roller Shutter Z-Wave Plus Module ManualwiDom Smart Roller Shutter Z-Wave Plus Module Manual
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
 
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual englishIn-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
 
Widom smart dimmer
Widom smart dimmerWidom smart dimmer
Widom smart dimmer
 
Manual SEC_SCS318 secure
Manual SEC_SCS318 secureManual SEC_SCS318 secure
Manual SEC_SCS318 secure
 
Fibaro RGBW controller manual
Fibaro RGBW controller manual Fibaro RGBW controller manual
Fibaro RGBW controller manual
 
wiDom Smart dry contact module Z-Wave Plus Manual
wiDom Smart dry contact module Z-Wave Plus ManualwiDom Smart dry contact module Z-Wave Plus Manual
wiDom Smart dry contact module Z-Wave Plus Manual
 
Fibaro Motion Multisensor Manual
Fibaro Motion Multisensor ManualFibaro Motion Multisensor Manual
Fibaro Motion Multisensor Manual
 
DUW 05457
DUW 05457DUW 05457
DUW 05457
 
For mim olite
For mim oliteFor mim olite
For mim olite
 
3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manual
3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manual3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manual
3 in 1 multi sensor Philio PSM01 (door, window, temperature, lightness) manual
 
manual dimmer - Zipato
manual dimmer - Zipatomanual dimmer - Zipato
manual dimmer - Zipato
 

Similar to Widom Z-WAve On/off relay switch 2.5KW manual English

Widom Relay withdry contact_en
Widom Relay withdry contact_enWidom Relay withdry contact_en
Widom Relay withdry contact_enDomotica daVinci
 
Manual smart TE dimmer Z-Wave -Widom
Manual  smart TE dimmer Z-Wave -WidomManual  smart TE dimmer Z-Wave -Widom
Manual smart TE dimmer Z-Wave -WidomDomotica daVinci
 
Manual widom universal roller shutter en
Manual widom universal roller shutter enManual widom universal roller shutter en
Manual widom universal roller shutter enDomotica daVinci
 
Fibaro Flood Sensor Manual
Fibaro Flood Sensor Manual Fibaro Flood Sensor Manual
Fibaro Flood Sensor Manual Domotica daVinci
 
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual englishWall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual englishDomotica daVinci
 
Manual Motor valve pop e009501
Manual Motor valve pop  e009501Manual Motor valve pop  e009501
Manual Motor valve pop e009501Domotica daVinci
 
Manual heatit z-water_analog inputs_fw 2.1_ver2019-a_eng
Manual heatit z-water_analog inputs_fw 2.1_ver2019-a_engManual heatit z-water_analog inputs_fw 2.1_ver2019-a_eng
Manual heatit z-water_analog inputs_fw 2.1_ver2019-a_engDomotica daVinci
 
Widom smart double_switch_l_en
Widom smart double_switch_l_enWidom smart double_switch_l_en
Widom smart double_switch_l_enDomotica daVinci
 
Manual steinel rs led d2 (indoor light with led)
Manual steinel rs led d2 (indoor light with led)Manual steinel rs led d2 (indoor light with led)
Manual steinel rs led d2 (indoor light with led)Domotica daVinci
 
V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08Cara Bereck Levy
 
Lec 8,9,10 (interfacing)
Lec 8,9,10 (interfacing)Lec 8,9,10 (interfacing)
Lec 8,9,10 (interfacing)Mohamed Atef
 
Wall plug switch with metering po pp start guide
Wall plug switch with metering po pp start guideWall plug switch with metering po pp start guide
Wall plug switch with metering po pp start guideDomotica daVinci
 
wiDom Smart Plug Manual EN
wiDom Smart Plug Manual ENwiDom Smart Plug Manual EN
wiDom Smart Plug Manual ENDomotica daVinci
 

Similar to Widom Z-WAve On/off relay switch 2.5KW manual English (20)

Widom Relay withdry contact_en
Widom Relay withdry contact_enWidom Relay withdry contact_en
Widom Relay withdry contact_en
 
Manual danfos danehc10
Manual danfos danehc10Manual danfos danehc10
Manual danfos danehc10
 
Mco_tps312
Mco_tps312Mco_tps312
Mco_tps312
 
Mco_tps314
Mco_tps314Mco_tps314
Mco_tps314
 
Manual smart TE dimmer Z-Wave -Widom
Manual  smart TE dimmer Z-Wave -WidomManual  smart TE dimmer Z-Wave -Widom
Manual smart TE dimmer Z-Wave -Widom
 
Manual widom universal roller shutter en
Manual widom universal roller shutter enManual widom universal roller shutter en
Manual widom universal roller shutter en
 
Fibaro Flood Sensor Manual
Fibaro Flood Sensor Manual Fibaro Flood Sensor Manual
Fibaro Flood Sensor Manual
 
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual englishWall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
 
Pop 123610 manual
Pop 123610 manual Pop 123610 manual
Pop 123610 manual
 
Manual Motor valve pop e009501
Manual Motor valve pop  e009501Manual Motor valve pop  e009501
Manual Motor valve pop e009501
 
SIG SENS W
SIG SENS WSIG SENS W
SIG SENS W
 
Manual heatit z-water_analog inputs_fw 2.1_ver2019-a_eng
Manual heatit z-water_analog inputs_fw 2.1_ver2019-a_engManual heatit z-water_analog inputs_fw 2.1_ver2019-a_eng
Manual heatit z-water_analog inputs_fw 2.1_ver2019-a_eng
 
Widom smart double_switch_l_en
Widom smart double_switch_l_enWidom smart double_switch_l_en
Widom smart double_switch_l_en
 
Manual steinel rs led d2 (indoor light with led)
Manual steinel rs led d2 (indoor light with led)Manual steinel rs led d2 (indoor light with led)
Manual steinel rs led d2 (indoor light with led)
 
V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08
 
Ex rc1 spec-en_1215
Ex rc1 spec-en_1215Ex rc1 spec-en_1215
Ex rc1 spec-en_1215
 
Lec 8,9,10 (interfacing)
Lec 8,9,10 (interfacing)Lec 8,9,10 (interfacing)
Lec 8,9,10 (interfacing)
 
Wall plug switch with metering po pp start guide
Wall plug switch with metering po pp start guideWall plug switch with metering po pp start guide
Wall plug switch with metering po pp start guide
 
Manual zmnhxd1
Manual zmnhxd1Manual zmnhxd1
Manual zmnhxd1
 
wiDom Smart Plug Manual EN
wiDom Smart Plug Manual ENwiDom Smart Plug Manual EN
wiDom Smart Plug Manual EN
 

More from Domotica daVinci

Manual de usuario Dongle Zigbee 3.0 Sonoff
Manual de usuario Dongle Zigbee 3.0 SonoffManual de usuario Dongle Zigbee 3.0 Sonoff
Manual de usuario Dongle Zigbee 3.0 SonoffDomotica daVinci
 
2Channel Dimmer Module Zigbee NetPlus Manual
2Channel Dimmer Module Zigbee NetPlus Manual2Channel Dimmer Module Zigbee NetPlus Manual
2Channel Dimmer Module Zigbee NetPlus ManualDomotica daVinci
 
Shelly Qubini Dry Contact Module Z-Wave Manual
Shelly Qubini Dry Contact Module Z-Wave ManualShelly Qubini Dry Contact Module Z-Wave Manual
Shelly Qubini Dry Contact Module Z-Wave ManualDomotica daVinci
 
Zi-Stick UBS Dongle ZIgbee from Aeotec manual
Zi-Stick UBS Dongle ZIgbee from  Aeotec manualZi-Stick UBS Dongle ZIgbee from  Aeotec manual
Zi-Stick UBS Dongle ZIgbee from Aeotec manualDomotica daVinci
 
Manual controlador de pared Zigbee quatro battery.pdf
Manual controlador de pared Zigbee quatro battery.pdfManual controlador de pared Zigbee quatro battery.pdf
Manual controlador de pared Zigbee quatro battery.pdfDomotica daVinci
 
MOES-User-Manual AL23-211223-MHUB-MS.pdf
MOES-User-Manual AL23-211223-MHUB-MS.pdfMOES-User-Manual AL23-211223-MHUB-MS.pdf
MOES-User-Manual AL23-211223-MHUB-MS.pdfDomotica daVinci
 
Tete thermostatique Zigbee MOES BRT-100 V2.pdf
Tete thermostatique Zigbee MOES BRT-100 V2.pdfTete thermostatique Zigbee MOES BRT-100 V2.pdf
Tete thermostatique Zigbee MOES BRT-100 V2.pdfDomotica daVinci
 
Cherubini Meta Z-Wave Double Switch A510083-84-90
Cherubini Meta Z-Wave Double Switch A510083-84-90Cherubini Meta Z-Wave Double Switch A510083-84-90
Cherubini Meta Z-Wave Double Switch A510083-84-90Domotica daVinci
 
Cherubini Meta Z-Wave Smart Plug Manual A510068
Cherubini Meta Z-Wave Smart Plug Manual A510068Cherubini Meta Z-Wave Smart Plug Manual A510068
Cherubini Meta Z-Wave Smart Plug Manual A510068Domotica daVinci
 
Wave_Shutter_user_guide_multilang_print_V3.pdf
Wave_Shutter_user_guide_multilang_print_V3.pdfWave_Shutter_user_guide_multilang_print_V3.pdf
Wave_Shutter_user_guide_multilang_print_V3.pdfDomotica daVinci
 
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdfQuinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdfDomotica daVinci
 
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdfZ-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdfDomotica daVinci
 
Manual Eurotronic Thermostatic Valve Comry Z-Wave
Manual Eurotronic Thermostatic Valve Comry Z-WaveManual Eurotronic Thermostatic Valve Comry Z-Wave
Manual Eurotronic Thermostatic Valve Comry Z-WaveDomotica daVinci
 
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
Manual  sensor Zigbee 3.0 MOES ZSS-X-PIRL-CManual  sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-CDomotica daVinci
 
zigbee motion sensor user manual NAS-PD07B2.pdf
zigbee motion sensor user manual NAS-PD07B2.pdfzigbee motion sensor user manual NAS-PD07B2.pdf
zigbee motion sensor user manual NAS-PD07B2.pdfDomotica daVinci
 
Range extender 7 - Aeotec - Manual
Range extender 7 - Aeotec - Manual   Range extender 7 - Aeotec - Manual
Range extender 7 - Aeotec - Manual Domotica daVinci
 
Aeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualAeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualDomotica daVinci
 
wiDom Multi Sensor Room Controller MSRC Manual EN
wiDom Multi Sensor Room Controller MSRC Manual ENwiDom Multi Sensor Room Controller MSRC Manual EN
wiDom Multi Sensor Room Controller MSRC Manual ENDomotica daVinci
 

More from Domotica daVinci (20)

Manual de usuario Dongle Zigbee 3.0 Sonoff
Manual de usuario Dongle Zigbee 3.0 SonoffManual de usuario Dongle Zigbee 3.0 Sonoff
Manual de usuario Dongle Zigbee 3.0 Sonoff
 
2Channel Dimmer Module Zigbee NetPlus Manual
2Channel Dimmer Module Zigbee NetPlus Manual2Channel Dimmer Module Zigbee NetPlus Manual
2Channel Dimmer Module Zigbee NetPlus Manual
 
Shelly Qubini Dry Contact Module Z-Wave Manual
Shelly Qubini Dry Contact Module Z-Wave ManualShelly Qubini Dry Contact Module Z-Wave Manual
Shelly Qubini Dry Contact Module Z-Wave Manual
 
Zi-Stick UBS Dongle ZIgbee from Aeotec manual
Zi-Stick UBS Dongle ZIgbee from  Aeotec manualZi-Stick UBS Dongle ZIgbee from  Aeotec manual
Zi-Stick UBS Dongle ZIgbee from Aeotec manual
 
Manual controlador de pared Zigbee quatro battery.pdf
Manual controlador de pared Zigbee quatro battery.pdfManual controlador de pared Zigbee quatro battery.pdf
Manual controlador de pared Zigbee quatro battery.pdf
 
MOES-User-Manual AL23-211223-MHUB-MS.pdf
MOES-User-Manual AL23-211223-MHUB-MS.pdfMOES-User-Manual AL23-211223-MHUB-MS.pdf
MOES-User-Manual AL23-211223-MHUB-MS.pdf
 
Tete thermostatique Zigbee MOES BRT-100 V2.pdf
Tete thermostatique Zigbee MOES BRT-100 V2.pdfTete thermostatique Zigbee MOES BRT-100 V2.pdf
Tete thermostatique Zigbee MOES BRT-100 V2.pdf
 
Cherubini Meta Z-Wave Double Switch A510083-84-90
Cherubini Meta Z-Wave Double Switch A510083-84-90Cherubini Meta Z-Wave Double Switch A510083-84-90
Cherubini Meta Z-Wave Double Switch A510083-84-90
 
Cherubini Meta Z-Wave Smart Plug Manual A510068
Cherubini Meta Z-Wave Smart Plug Manual A510068Cherubini Meta Z-Wave Smart Plug Manual A510068
Cherubini Meta Z-Wave Smart Plug Manual A510068
 
Wave_Shutter_user_guide_multilang_print_V3.pdf
Wave_Shutter_user_guide_multilang_print_V3.pdfWave_Shutter_user_guide_multilang_print_V3.pdf
Wave_Shutter_user_guide_multilang_print_V3.pdf
 
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdfQuinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
 
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdfZ-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
 
Manual Eurotronic Thermostatic Valve Comry Z-Wave
Manual Eurotronic Thermostatic Valve Comry Z-WaveManual Eurotronic Thermostatic Valve Comry Z-Wave
Manual Eurotronic Thermostatic Valve Comry Z-Wave
 
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
Manual  sensor Zigbee 3.0 MOES ZSS-X-PIRL-CManual  sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
 
zigbee motion sensor user manual NAS-PD07B2.pdf
zigbee motion sensor user manual NAS-PD07B2.pdfzigbee motion sensor user manual NAS-PD07B2.pdf
zigbee motion sensor user manual NAS-PD07B2.pdf
 
Range extender 7 - Aeotec - Manual
Range extender 7 - Aeotec - Manual   Range extender 7 - Aeotec - Manual
Range extender 7 - Aeotec - Manual
 
Aeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualAeotec Multisensor 7 Manual
Aeotec Multisensor 7 Manual
 
Z stick 7 user guide
Z stick 7 user guideZ stick 7 user guide
Z stick 7 user guide
 
ESB 200 H-Tronic Manual
ESB 200 H-Tronic ManualESB 200 H-Tronic Manual
ESB 200 H-Tronic Manual
 
wiDom Multi Sensor Room Controller MSRC Manual EN
wiDom Multi Sensor Room Controller MSRC Manual ENwiDom Multi Sensor Room Controller MSRC Manual EN
wiDom Multi Sensor Room Controller MSRC Manual EN
 

Recently uploaded

FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024The Digital Insurer
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MIND CTI
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...DianaGray10
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistandanishmna97
 
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfRising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfOrbitshub
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDropbox
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWERMadyBayot
 
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...apidays
 
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Jeffrey Haguewood
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesrafiqahmad00786416
 
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 AmsterdamDEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 AmsterdamUiPathCommunity
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProduct Anonymous
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FMESafe Software
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businesspanagenda
 
Vector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxVector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxRemote DBA Services
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoffsammart93
 
Platformless Horizons for Digital Adaptability
Platformless Horizons for Digital AdaptabilityPlatformless Horizons for Digital Adaptability
Platformless Horizons for Digital AdaptabilityWSO2
 

Recently uploaded (20)

FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering Developers
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfRising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor Presentation
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
 
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
 
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 AmsterdamDEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
 
Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
Vector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxVector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptx
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Platformless Horizons for Digital Adaptability
Platformless Horizons for Digital AdaptabilityPlatformless Horizons for Digital Adaptability
Platformless Horizons for Digital Adaptability
 

Widom Z-WAve On/off relay switch 2.5KW manual English

  • 1. EN English UMI-0104-240614 UBS 1.04 Operating instructions (R) (B) LN Ls1 2 UNIVERSAL RELAY SWITCH
  • 2. II Revision History Rev. Doc. Data Revisor Pag. Descrizione 1 24/06/2014 RC 6,7,8 ,12 Minor updates regarding text 10 Text “32 (0x1E)” changed in “32 (0x20)” Text “33 (0x1F)” changed in “33 (0x21)” Text “34 (0x1E)” changed in “34 (0x22)” Text “35 (0x1F)” changed in “35 (0x23)” Text “36 (0x1E)” changed in “36 (0x24)” Text “37 (0x1F)” changed in “37 (0x25)” 11 Text “0 – TIMER ENABLED” changed in “0 – TIMER DISABLED” Text “1 – TIMER DISABLED” changed in “1 – TIMER ENABLED” 12 Removed row “IGNORE” from first the table
  • 3. 1 Device description Line Phase connection terminals Null Neutral connection terminals Relay Contact Latching Relay Contacts Line signal This terminal gets a phase signal that drives the relay. The system recognises the status change of this connection (switch from 0 to phase voltage and vice versa) Reset Pressing this button the system will restart Push Button Service button: 1 or 3 clicks enters Learning Mode, with 6 clicks the System is reset to factory settings Technical Specification Power supply 230 VAC±10% 50/60 Hz Maximum Load 2500 VA – 250 VAC - 10A resistive load in AC 300 VA – 30 VDC – 10A resistive load in DC System temperature limitation 105 °C Work temperature 0 – 40° C Radio protocol Z-Wave 868,4 MHz Range up to 60 m outdoors, up to 30 m indoors Dimensions (HxWxD) 43x43x17 mm Consumption <210 mW Actuator element Latching relay Conformity CE, RoHs Push Button Reset LineNull Relay Contact Line signal (R) (B) LN Ls1 2
  • 4. 2 Introduction WiDom Universal Relay Switch is a Z-Wave certified “in wall device”. The device is based on the use of a latching relay that is combined with an innovative design and effective implementation to ensure extremely low energy consumption. WiDom Universal Relay Switch is designed for being installed in junction boxes, flush mount boxes and near lights. WiDom Universal Relay Switch is an ONOFF device and can be used as both a local and remote switch. It supports two wire connections, which allows it to be installed into any existing system without the need to change the wiring. At the same time, it is completely configurable so that it can adapt to the most varied needs while also being ready to be used without needing additional configurations in order to operate. Thanks to the framework developed by WiDom, the various types of “events” on the “External Switch” can be recognised and associated to actions to be performed on the device, andor on any associated devices andor on all devices on the network. The events that the system recognises are the number of “clicks” or hold on the External Switch. Although Z-Wave is quite new technology, it has already become recognizable and officially binding standard, similarly to Wi-Fi. Many manufacturers in various industries offer solutions based on Z-Wave technology, guaranteeing their compatibility. This means that the system is open and it may be extended in the future. External Switch: Any switch, button or traditional wall control connected to the device in order to turn it on or off. Events: The actions performed on the external Switch: Clicks or Hold. Click: If the external switch is a button (when pressed it returns to the start position by itself), a click means pressing and then releasing it. If the external switch is a bistable one (after being pressed it does not return to the original position), a single click means one single flip of the switch. Hold: This applies only to buttons that are normally open and that are identified as such when the pressure phase lasts at least 1,5 seconds. Device in ONOFF status refers to the fact that the latching relay contact is in the OpenClose position.
  • 5. 3 Installation WARNING: WiDom Universal Relay Switch must be installed by a certified electrician in compliance with the safety requirements set forth in national law regulations. DANGER: WiDom Universal Relay Switch must be connected to 240VAC. Before performing any installation operations, make sure the main switch on the meter is set to OFF. DANGER: Any procedure that calls for the use of the (R) and (B) service buttons is related only to the installation phase and is to be considered a service procedure that must be performed by qualified personnel. This operation must be performed with all necessary precautions for operating in areas with a single level of insulation. WARNING: Do not connect loads that exceed the maximum load permitted by the relay contacts. In the case of greater loads, WiDom Universal Relay Switch may be used to control an external relay or a contactor. For non-resistive loads, the maximum load must be appropriately reduced. WARNING: All connections must be performed according to the electrical diagrams provided WiDom Universal Relay Switch Activation 1) Make sure the mains switch is set to the OFF position 2) Connect the device based on the diagrams provided 3) Close the electrical box that contains the device 4) Turn the system back on 5) Include the device in the Z-Wave network TIP: The antenna must not be shortened, removed or modified. To ensure maximum efficiency, it must be installed as shown. Metal equipment near the antenna can negatively affect reception. Each WiDom device is a node in a mesh network. If there are metal obstacles, the obstacle can often be overcome with a further triangulation node. (R) (B) LN Ls1 2
  • 6. 4 Three-Wire connection The device must be supplied by phase and neutral. The third control wire carries a phase signal on the Ls terminal controlled by the external switch. Diagram A Diagram B N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls) Control contact N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls) Control contact *Maximum wire length<15m INFO: The external switch can be either a bistable, a normally opened button or any sequence of SPDT - DPDT (Fig.AB.1) or buttons (Fig.AB.2). Fig.AB.1 Fig.AB.2 INFO: If using a secondary load supply system, it must be connected as in diagram B. The supply voltage can be either AC or DC within the limits permitted by the relay contact, up to 250 V in AC and up to 30 V in DC. WARNING: The line connected to the relay contacts must be suitably protected from short circuits and overloads connected to a possible failure of the connected load L N (R) (B) LN Ls1 2  Bistable switch  Normally Opened monostable switch Secondary Power Supply System L N (R) (B) LN Ls1 2  Bistable switch  Normally Opened monostable switch L Ls Ls
  • 7. 5 Two wire connection - AC Sensing With this type of connection, the momentary interruption of the phase is interpreted by the system as a load switching command. This configuration is suitable for controlling existing lighting system. Diagram C Diagram D N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls) Control contact N) Neutral; L) Phase; 1 and 2) Relay contacts; Ls) Control contact *Maximum wire length<15m INFO: The external switch can be a normally closed button as well as any series, as shown in figure CD.1. Fig.CD.1 Fig.CD.2 TIP: In this mode, the device can be installed near the light to be controlled and the existing switch is replaced with a normally closed button. For a light controlled from several points, all of the switches should be replaced with normally closed buttons. Please note that in this case another connection that may work is shown in figure CD.2 where the necessary modified connection for just one of the switches is represented. TIP: In order to control a neon tube with a traditional ballast and a starter and in general with non-pure resistive loads or with long wire connections a WiDom Switch Helper should be connected in parallel to the load as shown in diagram C. INFO: If using a secondary load supply system, it must be connected as in diagram D. The supply voltage can be either AC or DC within the limits permitted by the relay contact, up to 250 V in AC and up to 30 V in DC. WARNING: The line connected to the relay contacts must be suitably protected from short circuits and overloads connected to a possible failure of the connected load. L N (R) (B) LN Ls1 2 Optional: WiDom Switch Helper  Normally Closed monostable switch Secondary Power Supply System L N (R) (B) LN Ls1 2  Normally Closed monostable switch LsL L
  • 8. 6 Reset to the factory settings The device can be reset to the original factory settings using one of the following methods: Method 1: Remove the device from the Z-Wave network Method 2: Six consecutive clicks on button (B) Method 3: Set parameter 61 to value 0 - FACTORY RESET (see paragraph 0). INFO: If the reset is performed while the device is still part of a network, it notifies the other devices that it has been removed (Device Reset Locally Notification). If WiDom Universal Relay Switch receives a removal notification from another device, it will delete the removed device from its own associations. Including the device into an existing Z-Wave network WiDom Universal Relay Switch can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. As constantly powered node WiDom Universal Relay Switch will act as repeater regardless of the vendor in order to increase reliability of the network. The device supports both the Network Wide Inclusion mechanism (which offers the ability to be included in a network even if the device is not in the direct range of the controller) and Normal Inclusion. By default, if the device is not included in any network, as soon as it is powered the Network Wide Inclusion procedure starts and lasts for about 1 minute. The procedure can be reactivated at the next device restart or by pressing the (R) button. If the used controller does not support the Network Wide Inclusion functionality, the device may be included in the network through Normal Inclusion by pressing the (B) button once or three times or alternatively by pressing the external switch once. INFO: During the inclusion procedure activated by a single click on the external switch, the system also automatically determines the switch type (See parameter No. 62). Excluding the device from a Z-Wave network Only a controller can remove a device from the network. WiDom Universal Relay Switch is compatible with all Z-Wave certified controllers. After the exclusion function has been activated from the controller, the device can be removed, putting it in Learning Mode by pressing the (B) button once or three times or more conveniently by using the external switch after having enabled the learning mode activation from external switch (see parameter N°65). Request network update If there is a SUC (Static Update Controller) or SIS (SUC ID Server) in the network, a network update can be requested by pressing the external switch four times. Associations WiDom Universal Relay Switch can control other devices like other relays or dimmers. WiDom Universal Relay Switch supports 5 association groups: Group 1: devices that will be notified of changes in its status Group 2: devices that will be controlled by a single click on the external switch Group 3: devices that will be controlled by a double click on the external switch Group 4: devices that will be controlled by a triple click on the external switch Group 5: devices that will be controlled by hold on the external switch TIP: WiDom Universal Relay Switch can control up to 16 devices for each group. To avoid network delays, we recommend limiting the amount of associated devices to no more than 5 per group.
  • 9. 7 Controlling the device with an external switch With WiDom devices, the normal switches/buttons found in a traditional electrical system can become intelligent control systems. WiDom Framework recognises the number of clicks or hold event on the external switch and can be configured to perform different actions based on the identified event. Controlling the device via the Z-Wave network All Z-Wave controllers can control the device using the Basic Set command. The behaviour of the device based on its status and on the commands received from the network can also be configured. Alarms management WiDom Universal Relay Switch can also be configured to react to alarm notifications from sensors on the network. WiDom Universal Relay Switch recognises and complies with Notification V3 Report frame alarm notifications. INFO: By default, WiDom Universal Relay Switch reacts to smoke, heat, water and home security alarms generated by others Z-Wave sensors in the system. The reaction type: ON, OFF or FLASHING can be configured as needed. Switch ALL ONOFF By default, WiDom Universal Relay Switch accepts Switch All ONOFF commands. Timer option WiDom Universal Relay Switch has a built-in configurable timer for programmed switch-off. Troubleshooting By pressing the (B) and (R) buttons at the same time and then releasing (R), the system starts a check procedure that can produce one of the following results: 1. If the device is included in a network, it switches from ON to OFF repeatedly with equal ON and OFF times of 2 seconds each. 2. If the device is not included in a network, it switches from ON to OFF repeatedly with an ON time of 2 seconds and an OFF time of 6 seconds. INFO: The procedure described lasts until the (R) button is pressed again. Configurations Controlling the device by external switch Clicks on the external switch turn the connected load on or off depending on the initial status, on the number of clicks and on the device configuration. The actions that will be performed on the associated devices and on all other devices on the network can also be configured. INFO: As soon as the click recognition process has completed, the device will be set to the desired status, any switch all onoff actions will be performed and the associated devices will be controlled.
  • 10. 8 Device status The final device status will be determined by the initial status, number of clicks or hold. The following configurations can be used to configure parameters 1 through 4. Value Initial status Final status 1 – TOGGLE ON OFF OFF ON 2 – ON ON If the initial status is OFF, the system will switch ON; otherwise, it maintains its status (ON).OFF 3 – OFF ON If the initial status is ON, the system will switch OFF; otherwise, it maintains its status (OFF).OFF 4 – IGNORE ON The device maintains its initial status and if the programmed switch- off timer is active, it is restarted.OFF Parameter No. 1: Device status when the external switch receives 1 click (1 byte). Default value: 1 – TOGGLE Parameter No. 2: Device status when the external switch receives 2 clicks (1 byte). Default value: 1 – TOGGLE Parameter No. 3: Device status when the external switch receives 3 clicks (1 byte). Default value: 1 – TOGGLE Parameter No. 4: Device status when the external switch is held down (1 byte) - This parameter only takes effect if a normally open button is connected. Default value: 1 – TOGGLE WARNING: Careless usage of the configuration parameters can create inconsistencies. Controlling the associated devices The actions performed on associated devices in terms of Basic Set will be determined by the initial status, number of clicks or hold. The following configurations can be used to configure parameters 5 through 8. Configuration Initial device status Action performed on the associated device 1 – TOGGLE ON Basic Set OFF_LEVEL OFF Basic Set ON_LEVEL 2 – IGNORE IF ON ON No action OFF Basic Set ON_LEVEL 3 – IGNORE IF OFF ON Basic Set OFF_LEVEL OFF No action 4 – TOGGLE ASSOCIATED ON The status of each associated device is requested with the Basic Get command. If it is OFF, the Basic Set ON command is sent, otherwise the Basic Set OFF command is sent.OFF 5 – SET AS INITIAL STATUS VALUE ON Basic Set ON_LEVEL OFF Basic Set OFF_LEVEL 6 – IGNORE ON No action OFF TIP: TOGGLE ASSOCIATED: This configuration is useful for configuring the device as a remote switch. We recommend this configuration for controlling a single remote device. When using this option, in order to avoid any inconsistent result, we recommend keeping the Switch All actions disabled.
  • 11. 9 Parameter No. 5: Action on the associated devices when the external switch receives 1 click (1 byte). Default value: 1 – TOGGLE Parameter No. 6: Action on the associated devices when the external switch receives 2 clicks (1 byte). Default value: 1 – TOGGLE Parameter No. 7: Action on the associated devices when the external switch receives 3 clicks (1 byte). Default value: 6 – IGNORE Parameter No. 8: Action on the associated devices when the external switch is held down (1 byte). Default value: 1 – TOGGLE Switch ALL functionality The actions performed on all network devices in terms of Switch ALL will be determined by the initial status, number of clicks or hold. If there are associated devices and there are control actions set for these devices, the Switch ALL actions are performed first. The following configurations can be used to configure parameters 9 through 12. Value Initial device status Action performed on all devices in the network 1 – TOGGLE ON SWITCH ALL OFF OFF SWITCH ALL ON 2 – IGNORE IF ON ON No action OFF SWITCH ALL ON 3 – IGNORE IF OFF ON SWITCH ALL OFF OFF No action 4 – SET AS INITIAL STATUS VALUE ON SWITCH ALL ON OFF SWITCH ALL OFF 5 – IGNORE ON No action OFF Parameter No. 9: Action performed on all network devices when the external switch receives 1 click (1 byte). Default value: 5 – IGNORE Parameter No. 10 (0xA): Action performed on all network devices when the external switch receives 2 clicks (1 byte). Default value: 5 – IGNORE Parameter No. 11 (0xB): Action performed on all network devices when the external switch receives 3 clicks (1 byte). Default value: 5 – IGNORE Parameter No. 12 (0xC): Action performed on all network devices when the external switch is held down (1 byte). Default value: 5 – IGNORE
  • 12. 10 Controlling the device by Z-Wave Network The device final status reached by the device when it receives a Basic Set command from the Z-Wave network. Parameter No. 20 (0x14): Device status upon receipt of a Basic Set (1 byte) Value Command received Final status 1 – HOW RECEIVED (Default value) ON ON OFF OFF 2 – IGNORE IF ON ON Maintains the initial status OFF OFF 3 – IGNORE IF OFF ON ON OFF Maintains the initial status 4 - IGNORE ON Maintains the initial status and, if the programmed switch-off timer is active, it is restarted.OFF Setting ON_LEVEL and OFF_LEVEL Defines the values associated to the ON_LEVEL and OFF_LEVEL parameters used in the Basic Set commands. The following values can be used to configure parameters 30 through 37. From: 0 (OFF) to 255 (ON) Parameter No. 30 (0x1E): ON_LEVEL value used for devices belonging to Group 2 (1 Click association group) (1 byte). Default value 255 – ON Parameter No. 31 (0x1F): OFF_LEVEL value used for devices belonging to Group 2 (1 Click association group) (1 byte). Default value 0 – OFF Parameter No. 32 (0x20): ON_LEVEL value used for devices belonging to Group 3 (2 Click association group) (1 byte). Default value 255 – ON Parameter No. 33 (0x21): OFF_LEVEL value used for devices belonging to Group 3 (2 Click association group) (1 byte). Default value 0 – OFF Parameter No. 34 (0x22): ON_LEVEL value used for devices belonging to Group 4 (3 Click association group) (1 byte). Default value 255 – ON Parameter No. 35 (0x23): OFF_LEVEL value used for devices belonging to Group 4 (3 Click association group) (1 byte). Default value 0 – OFF Parameter No. 36 (0x24): ON_LEVEL value used for devices belonging to Group 5 (Hold association group) (1 byte). Default value 255 – ON Parameter No. 37 (0x25): OFF_LEVEL value used for devices belonging to Group 5 (Hold association group) (1 byte). Default value 0 – OFF
  • 13. 11 Timer Option Enabling the timer for relay switch-off The switch-off timer can be associated with any click or hold event. When the timer is enabled for the specific event that generated the ON status, the device will go into the OFF status after the period of time defined in parameter No. 45. The following configuration values can be used for parameters 40 through 44. 0 – TIMER DISABLED 1 – TIMER ENABLED Parameter No. 40 (0x28): Timer associated with the 1 click event on the external switch (1 byte) - Enables the switch-off timer if the device switches to ON following a single click on the external switch. Default value: 0 – TIMER DISABLED Parameter No. 41 (0x29): Timer associated with the 2 click event on the external switch (1 byte) - Enables the switch-off timer if the device switches to ON following a double click on the external switch. Default value: 0 – TIMER DISABLED Parameter No. 42 (0x2A): Timer associated with the 3 click event on the external switch (1 byte) - Enables the switch-off timer if the device switches to ON following a triple click on the external switch. Default value: 0 – TIMER DISABLED Parameter No. 43 (0x2B): Timer associated with the hold event on the external switch (1 byte) - Enables the switch-off timer if the device switches to ON following hold on the external switch. Default value: 0 – TIMER DISABLED Parameter No. 44 (0x2C): Timer associated with the reception of a Basic Set command (1 byte) - Enables the switch-off timer if the device switches to ON following reception of a single click Basic Set command. Default value: 0 – TIMER DISABLED Parameter No. 45 (0x2D): Switch-off timer (2 bytes) Defines the amount of time before the switch-off timer takes place Time in seconds (1 – 3600); Default value 600 (0x258), 10 minutes. Parameter No. 46 (0x2E): Switch-off timer validity (1 byte) - Defines the system behaviour if an event requests a status change for the device and the timer for the programmed switch-off timer was started by a previous event. Configuration Device reaction 0 - CANCEL The switch-off timer is cancelled and the device maintains the last status reached. If the new status is ON and the event that generated it is associated with the timer, it is restarted. 1 - MAINTAIN Default value The switch-off timer is maintained Manage Alarms WiDom devices can react to alarms received. The system recognises alarm messages (version 3 of Alarm Command Class). By default, all alarms are ignored except for those defined in the following table: Alarm Alarm or Notification Type Event Event Parameters Smoke Alarm, CO, CO2 0x01 – 0x02 – 0x03 ANY ANY Heat Alarm 0x04 ANY ANY Water Alarm 0x05 ANY ANY Home Security 0x07 ANY ANY
  • 14. 12 The way the device reacts when it receives an alarm can be customised using parameters 50 through 53. Configuration Device reaction 1 – ON The device status switches to ON 2 – OFF The device status switches to OFF 3 – FLASH The device switches from ON to OFF with a frequency and duration that can be customised using parameters 54, 55 and 56. 4- IGNORE The alarm will be ignored Parameter No. 50 (0x32): Smoke Alarm, CO, CO2 Action (1 byte) - Defines how the device reacts when it receives one of the following types of alarms: smoke, CO or CO2. Default value: 1 – ON Parameter No. 51(0x33): Heat Alarm (1 byte) - Defines how the device reacts when it receives Heat Alarm. Default value: 1 – ON Parameter No. 52(0x34): Water Alarm (1 byte) - Defines how the device reacts when it receives Water Alarm. Default value: 2 – OFF Parameter No. 53 (0x35): Home Security (1 byte) - Defines how the device reacts when it receives Home Security alarm. Default value: 3 – FLASH Parameter No. 54 (0x36): ON time during flashing (1 byte) Defines the number of seconds for the ON status during flashing - (from 1 to 255). Default value: 5 seconds Parameter No. 55 (0x37): OFF time during flashing (1 byte) Defines the number of seconds for the OFF status during flashing - (from 1 to 255). Default value: 5 seconds Parameter No. 56 (0x38): Duration of flashing phase (1 byte) - Defines the time in minutes from the last receipt of the last alarm message received - (from 1 to 255). Default value: 10 minutes Other configuration parameters Parameter No. 60 (0x3C): Startup status (1 byte) - Defines the status of the device after a restart following a reset or black out. Configuration Device reaction 1 – ON Device ON 2 – OFF Device OFF 3 – PREVIOUS STATUS (Default value) Status before the restart Parameter No. 61 (0x3D): Configuration reset (1 byte) Defines which parameters must be reset to defaults. Configuration Device reaction 0 – FACTORY RESET The device is reset to the original factory settings. 1 – RESET ASSOCIATIONS All associations and only the associations are reset 2 – RESET CONFIGURATIONS The associations are maintained while all of the other configuration parameters are reset to the original factory settings except for this specific configuration. 4 – IGNORE (Default value) No action is performed Parameter No. 62 (0x3E): Type of external switch (1 byte) - Defines the type of external switch connected to the device.
  • 15. 13 Configuration Device reaction 0 – IGNORE The actions on the external switch are ignored. In this mode, the device can only be controlled via the network. 1 – BUTTON The external switch is a normally open button 2 – BISTABLE SWITCH The external switch is a traditional switch 3 – AC SENSING The external switch is a normally closed button connected as shown in diagrams C and D 4 – AUTOMATIC RECOGNITION (Default value) After the first single click on the external switch, the system automatically determines the type of external switch used and accordingly sets the parameter with the new value. Parameter No. 63 (0x3F): Sensitivity (1 byte) - Sets the level of sensitivity associated with the AC SENSING configuration.The value can be set between 0 (High sensitivity) and 255 (Low sensitivity). Default Value: 9 Parameter No. 64 (0x41): Load protection (2 bytes) Defines the minimum amount of time in which the switch cannot be flipped twice in succession. Time in seconds (1 – 3600). Default value: 0 INFO: Some types of loads require a rest period between switch-off and subsequent switch-on. This parameter is for setting this time. If this parameter is set and the load is off, when the device receives a switch-on command, it will be performed as soon as the protection time has been reached. Parameter No. 65 (0x40): Learn Mode (1 byte) - This defines the sequence of clicks on the external switch to associate to Learning Mode. Configuration Device reaction 0 – DISABLED (Default value) Learning mode cannot be activated from the external switch 1 – 1 CLICK Learning mode is activated by 1 click on the external switch 2 – 2 CLICKS Learning mode is activated by 2 clicks on the external switch 3 – 3 CLICKS Learning mode is activated by 3 clicks on the external switch INFO: When Learning mode is associated to a click event any configurations related to the associated devices and Switch All commands related to the same event are ignored. After the learning mode has been associated to a click event this configuration is honoured for a single event. After that event the Learning mode parameter will be reset to the default value (0 – DISABLED). Compliance with directives WiDom devices are built in compliance with directives LVD 2006/95/EC, EMC 2004/108/CE and R&TTE Widom shall not be held responsible for any damage caused by these devices if they are used in a manner that is not compliant with the instructions in this manual. WiDom reserves the right to make any changes to the product that it considers necessary or useful without jeopardising its primary features. Warranty This warranty is provided by WiDom srl (hereinafter “WiDom”) based in Quartu S.Elena 09045 (CA), Italy (VAT number 03452490927). WiDom warrants to the original purchaser (hereinafter “Customer”) that the device sold under this agreement (hereinafter “Device”) is free from defects in parts and workmanship under normal use for 12 months from date of purchase (“Warranty Period”). The original purchase invoice or sales receipt, showing the date of purchase is the proof of date of purchase by the Customer.
  • 16. 14 If a Device, sold by WiDom to the Customer, has manufacturing defects or in any case of alleged lack of conformity, the Customer shall send within thirty (30) days from the day in which he discovers such defects, a claim form by using our web site: (www.widom.it) informing WiDom on the full name of the Customer, the nature of the defects and the date in which the Devices has been purchased. Warranty Claims received after the expiration of the Warranty Period shall not be considered valid. Once WiDom, receives the Warranty Claim, it shall inform the Customer by e-mail or letter, if the Warranty is applicable and the address where the Device shall be sent in order to verify the defects (if any). Customer must prepay shipping and transportation charges as indicated by WiDom. The Device shall be sent by the Customer to WiDom at its own costs and expenses, by express courier or hand delivered, and with the original packaging, the supplied accessories (if any) and documents proving date of purchase. WiDom shall then inform the Customer about the defects and on its repair or replacement (where applicable). Should WiDom not evidence defects on the Device, the Device shall be returned to the Customer. Should WiDom notices the defects, and this warranty is applicable, it will remove, at its sole discretion, any defect, free of charge, by repairing any defective components of the Device with new or regenerated components or by replacing the Device. The Warranty Period of the replaced or repaired Device shall not be extended. WiDom will ship the repaired or a replaced Device to Customer freight prepaid. WiDom will not be liable for damages to property caused by faulty device. WiDom will not be liable for indirect, incidental, special, consequential or punitive damages, or for any damage, including, inter alia, loss of profits, savings, data, loss of benefits, claims by third parties and any property damage or personal injuries arising from or related to the use of the Device. If the Device cannot be replaced with another of the same type (e.g. the Device is no longer in production or no longer available for selling in the Customer’s country), it may be replaced with a different one having similar technical specifications to the faulty one. Such replacement shall be considered as a total fulfilment of WiDom’s obligations. Warranty exclusion - defects caused by normal wear of parts or especially subject to wear, such as parts that require periodic replacement during the normal operation of the system (eg. Batteries); - splits, cracks, scratches, dents, scratched or discolored surfaces and parts, breakage of plastic parts and in general of any other cosmetic damage; - damages resulting from use of the system other than that provided, including but not limited to the failure to follow instructions contained in the operating manual; - damages caused by accident, abuse, misuse, dirt, viruses, liquid contact, fire, earthquake, improper or inadequate maintenance or calibration, negligence or other external causes; - environmental damage and / or defects caused by smoke, dust, dirt, soot, or other external influences; - damages caused by modifications and alterations in the functionality or features without the written permission of WiDom; - damages resulting from transportation or inadequate packaging when returning the product to a WiDom or to an authorize service center; - defects caused by force majeure events such as lightning, floods, fires, incorrect voltage, improper ventilation; - damages caused by malfunctioning software, computer virus attack, or by failure to update the software as recommended by WiDom; - damages resulting from surges in the power and/or telecommunication network, improper connection to the grid in a manner inconsistent with the operating manual, or from connecting other devices not recommended by WiDom; - damages caused by operating or storing the device in extremely adverse conditions, i.e. high humidity, dust, too low (freezing) or too high ambient temperature; - products whose serial number has been removed, damaged or rendered illegible; - expiration of the Warranty Period. If a defect is not covered by the Warranty, WiDom will inform the Customer about the extra expenses for the repair or replacement. This warranty may be subject to changes. Please check at: www.widom.it the newest warranty claim procedure. This guarantee shall not exclude, limit or suspend the Customer rights when the provided product is inconsistent with the purchase agreement.
  • 17. 15 © All rights reserved. WiDom is a trademark of WiDom srl. All other brand names, product names, or trademarks belong to their respective owners. WiDom reserves the right to change product features and specifications at any time without notice, and is not responsible for typographical or graphical errors that may appear in this document. Printed in Italy on low-impact recyclable paper.