The Model T23 two-wire transmitter can measure pH, ORP, specific ions, dissolved oxygen, conductivity and resistivity using various sensors. It has multi-channel capability to accept up to two sensor inputs with temperature compensation and provides up to three isolated outputs. It features predictive sensor diagnostics to reduce downtime and auto buffer calibration for easy maintenance. Power options include 24VDC loop-powered or 110/220VAC with isolated outputs and optional outputs like PID control or relays.
Coefficient of Thermal Expansion and their Importance.pptx
Model T23 Transmitter pH, ORP, Ion Sensors
1. Model T23 Transmi ers
ELECTRO-CHEMICAL DEVICES
Measure pH, ORP, Specific Ion, Dissolved Oxygen,
Conduc vity or Resis vity with
Model S10 or S17 Sensors
Model T23 Transmi er
2. Descrip on
The Model T23 two-wire transmi er provides simplicity in a
powerful package. A choice of measurement parameters
include: pH, ORP, Specific Ion, Dissolved Oxygen, Conduc vity
and Resis vity.
MULTI-CHANNEL CAPABILITY allows the Model T23 to accept
up to two sensor inputs, each having temperature
compensa on, and provides up to three selected outputs.
Any combina on of pH, ORP, Specific Ion, or Dissolved Oxygen
can be accepted as an input. (Conduc vity or Resis vity
transmi ers are only available as single channel units)
The SENTINEL is the next genera on sensor technology. By
u lizing the “SENTINEL” sensor reference diagnos cs, the user
can easily monitor the reference electrode’s degrada on due
to deple on or process contamina on. The “prephault”
indica on is clearly displayed as a bar graph on the main
process menu (or as an op onal output). The bar graph will
flash when it is me to replace an electrode. This feature
allows just in me delivery of the consumable component of
the sensor, elimina ng unforeseen down me.
Model T23 Transmi er
pH, ORP, pION
SENTINEL
“prepHault”
Sensor Diagnos cs
Mul -Channel and
Mul ple Sensor
Op ons
FeaturesFeatures
• Choice of mul ple measurement
parameters
• Two Channel Capability
• SENTINEL Diagnos cs
• Isolated Outputs
• Auto Buffer Calibra on
• 24 VDC loop-powered or
110/220 VAC power op on
• Mul ple Moun ng Configura ons
BenefitsBenefits
• Measure pH, ORP, Specific Ion,
Dissolved Oxygen, Conduc vity,
and Resis vity
• Lower cost with mul ple sensor
opera on
• Predic ve sensor diagnos cs
reduces down me
• Protects overall system inputs and
outputs
• Ease of Maintenance
• Minimize wiring & overall
installa on cost
• Pipe, Wall, Handrail, or Panel
Installa on choices
3. T23 Displays with
Measurement Parameters
Model T23 Transmi er
The AUTO BUFFER CALIBRATION feature allows the user to
perform buffer calibra ons that are stored in memory for
future reference. A er the buffer points have been ini ally
stored in memory, ac vate calibra on and insert the sensor
into standard solu ons. Wait for the sensor reading to
stabilize and save the data. There are no buffer value
adjustments to make.
The simplicity of the T23 transmi er allows one person to
quickly perform calibra ons through the power of the micro
processor. All configura on and calibra on func ons are
easily performed via the membrane key pad elimina ng the
need for any mechanical poten ometer adjustments. The
membrane keys allow for easy calibra ons while insuring
NEMA 4X environmental integrity.
ISOLATED OUTPUTS are standard with the Model T23. The
Model T23 accepts signals from various ECD sensors,
processes the informa on and provides up to three fully
isolated 4-20mA or 20–4mA outputs. The outputs are
expandable and reversible.
OPTIONAL OUTPUTS are available with the Model T23,
including a three-mode propor onal control output for any
measured parameter. Other outputs available are differen al,
average and ra o outputs. An addi onal relay op on
provides (two) 5 amp relays that can be used as alarm or
control set points.
POWER REQUIREMENT of the Model T23 is typically 24 VDC
loop-powered with an op onal 110/220 VAC power supply.
In case of power interrup on, the calibra on and
configura on data are retained in the EEPROM memory.
CONDUCTIVITY TRANSMITTERS- If an applica on requirement
includes resis vity, conduc vity, or specific concentra on
measurement, the Model T23 Transmi er will provide a new
level of simplicity and reliability. Built in sensor diagnos cs
indicate the validity of the sensor measurement with each
calibra on. Sensor models are available for both magne c
and contac ng type sensors. Common applica ons include:
sulfuric acid, TDS, sodium hydroxide, boiler blow-down,
cooling tower water control and leak detec on.
Isolated Outputs
Up to 3 independent
4 to 20 mA signals
Op onal Outputs
PID Control
Temperature
SENTINEL Diagnos cs
Differen al
Average
Ra o
(Two) 5 Amp Relays
+24 VDC, 4 to 20 mA
Loop Powered
Op ons
Internal 110/220 VAC
power supply
Calibra on
Auto Buffer Cal
One Person Cal
4. Moun ng Dimensions - (inches)
Specifica ons
Model T23 Transmi er
Measurement Range
pH: -2 to 14.5 pH
ORP: -1000 to 1000 mV
Specific Ion: 1 to 1000 ppb,
ppm, ppt
Dissolved O2: 0 to 40 ppm, mg/l
or % satura on
Conduc vity: 0 to 2 Siemens
Resis vity: 0 to 2 meg-ohms
0 to 20 meg-ohms
Display
Menu driven, 32 character
alphanumeric, Supertwist LCD,
The main menu simultaneously
displays; (1) Process Iden ty, (2)
Process Value and Engineering
Units, (3) Percent Output,
(4) Temperature in °C or °F.
Opera ng Temperature
-20° C to 70° C (-4° F to 158° F)
Temperature Compensa on
Automa c with RTD,-30°C to 140°C
(-22°F to 284°F ) Accuracy within
+/- 0.1° C from 0° to 100°C (32°F
to 212°F ).
Output
4-20 mA or 20-4 mA, linear and
expandable. Up to a maximum of
three outputs.
Op onal USB Datalogger
Input Power
+24 VDC nominal (13.5 to 50 VDC)
Op onal 110/220 VAC @ 50-60Hz
Relay Ra ngs (op onal)
5A @ 250VAC / 5A @ 30 VDC
resis ve max. (2) SPDT
Max Loop Impedance 525 ohms @
24 VDC for 4-20 mA compliance on
primary output; approximately
800 ohms on secondary outputs.
Accuracy
+/- 0.10% of full scale
Linearity
+/- 0.05% of full scale
Sensi vity
+/- 1.0 mV
Repeatability
+/- 1.0 mV
Response Time
T90 in 1 second
Noise Rejec on 50/60 Hz
Greater than 70 db
Input / Output Isola on
Maximum 300 volts between
process input and any 4-20 mA
output (single and mul ple
channel outputs). No Isola on
between inputs on mul ple
channel instruments.
Enclosure
NEMA 4X, weatherproof, ½ DIN,
(L x W x D) 5.7” X 5.7” X 3.0”
(14.4cm X 14.4cm X 8.9cm)
Shipping Weight
1.6 lbs (0.7kg)
Specifica ons subject to change without no ce.
Represented by:
T23 - B0813
Electro-Chemical Devices
1681 Ke ering
Irvine, California, USA 92614
Phone: +1-949-336-6060
+1-800-729-1333
Fax: +1-949-336-6064
email: sales@ecdi.com