2. Q A
1
Do you produce by yourselves
in your own factories?
Own( not rent) an area of more than 20000 square meters factory
place.
Register Capital :RMB100,000,000 (USD 15 Million )
- National industrial production permit
- Import &Export licence
- Quality management system ISO 9001
- Environmental Management ISO14001
- Occupational Health & Safety OHSAS 18001
2
Type of products
manufactured by Audsun and
annual quantities:
Heat Pump Water Heater :
- Equipement match production capacity:60000 units/ year
- Year 2014 &2015 production and sale volume: 35000 units/ year
Domestic Market: 72% (60% Commercial Heat Pump 40% Sanitary
Hot Water Unit
Overseas Market: 28%
3
Share of our swimming pool
heat pump in total production
8% (2800~3000Units)
4 Our Brand : Audsun
5 Total number of employee: 120
6
Number of employee in R&D
department:
12
7
Number of employee in
Quality department:
10
3. 8 2015 Total turn over in USD: USD 11.5 Million
9 2015 Export turn over in USD: USD 3.22 Million
10 Type of compressor used: Panasonic /Colepand/Hitachi/GMCC
11
Type of heat exchanger used :
DHW Model :Copper Heat Exchanger
12 SWHP Model :Titanium Pipe in PCV Shell or SUS316 Shell
13 Main refrigerant used : R417A/R410A/R134A/R22/R407C
14 Have you CE approval? YES
15 Other approval? G.S/ CB/ (Erp Label for the EVI heat pump tested by TUV)
16
Range of outside air
temperature possible for use of
your swimming pool heat pump:
-5℃~+43℃
17
Range of power of Audsun
swimming pool heat pump:
4kw~105kw
18
Type of housing? UV and
corrosion resistance?:
Galvanized steel sheet and sprayed baking paint
Stainless Steel SUS304
Plastic
19 Guarantee proposed: General 18 Months /Extra cost extend guarantee period available
4. Technical Support
R&D Center : 12 experienced engineers who
served in hot water industry average 8 years,
professional at different types of heat pump
original design.
Each unit of new product must have 3D design
presentation in computer before prototype
production .
6. Factory Glance
Ultra Gold Fin Evaporator
are coated with an epoxy
resin layer
Monthly Production Capacity:
7500pcs
7. Factory Glance
Outer Case Workshop:
Monthly Production Capacity:
5000pcs
The company introduced the high
end and famous brand “AMADA”
equipment from Japan .
8. Heat Pump Production Line
Assembly Workshop Monthly Production Capacity:
Commercial Model:1200 pcs
Domestic Model: 3000pcs
1-Components inspection
before production.
Check leakage before being
assembled.
9. Heat Pump Production Line
QC checks every electronic
Parts carefully before
sending them for heat
pump production.
11. Heat Pump Production Line
First Check Leak
Fill 3Mpa Nitrogen into every system and then totally immerses the close loop
system into the pool
(100% QTY check)
12. Heat Pump Production Line
Each Unit of heat pump have one trace card record all of the parameter during
manufacturing process ,such as testing pressure, refrigerant weight, commissioning
data,etc So that we can trace records of every unit every order and monitor &review
the entire quality control process.
13. Heat Pump Production Line
Vacuum System
&
Filling Gas
Refrigerant charging equipment:
Various volume of refrigerant is to be set before Charging
14. Heat Pump Production Line
Second Time Check Leak
Leakage detecting
equipment
When sniffer head detects smell of
refrigerant, It will give a alarming sound—
Beep when leakage has been found.
15. Factory Glance
Electric Box Installation
Safty Check
Each heat pump is carefully checked by our 4-in-1 electrical safety facility on :
high voltage resistance/ leak circuit/ grounding protection / insulation protection.
16. Commissioning & Performance Testing
Factory Glance
All heat pumps will be operation different modes for performance inspection,
cooling and heating .
17. Factory Glance
Third Time Check Leak before Packing
Careful leakage checking on whole piping system for the third time before
packing the heat pump.
18. Factory Glance
Export Sales Sampling before Packing
The export sales who take charge of the contract ,must do inspection of every
model , each order , double check the nameplates, remark compressor models,
take photos of the PCB wiring connections, check all of the labels and stickers,
check the accessories package ,etc . Make sure everything must meet the
customers’ request. These inspection photos kept by individual document file in
computer ,also will be sent to the customers for reference before each shipment.
20. Factory Glance
The Audsun Enthalpy Difference Testing Lab
Chinese Heat Pump Authority CCC Certified Testing Lab: The Audsun Enthalpy Difference Testing
Lab is used to measure the performance of various kinds of heat pumps by simulating various
temperature and humidity conditions .
24. Questions or Queries
Any Further queries please don’t hesitate to contact :
Guangdong Audsun Electric Technology Co.,Ltd
Ms. Ivy Liang
Deputy Director of Overseas Sales Dept.
Web Site: http://www.audsun.com
E-mail: ivy-export@audsun.com