Assessment of boiler performance

A
Ashish Kumar JainO & M HEAD em ASHISH KUMAR JAIN
ENERGY PERFORMANCE
ASSESSMENT OF BOILERS
ASHISH KUMAR JAIN
Performance Terms and Definitions
Heat output
Heat Input
Boiler Efficiency,  =
Heat in steam output (kCals)
Heat in Fuel Input (kCals)
Quantity of Steam Generation
Quantity of fuel Consumption
Evaporation Ratio =
The efficiency of a boiler is expressed as the % of useful heat
available from the total energy available by burning the fuel.
This is expressed on the basis of gross calorific value (GCV) .
Standards
British standards, BS845: 1987
This describes the methods and conditions under which a boiler
should be tested.Boiler should be operated under steady load
conditions (generally full load) for a period of one hour before taking
reading
ASME Standard: PTC-4-1 Power Test Code for Steam Generating
Units
q Part One: Direct method (also called as Input -output method)
q Part Two: Indirect method (also called as Heat loss method)
IS 8753: Indian Standard for Boiler Efficiency Testing
All standards do not include blow down as a loss in the efficiency
determination process.
Direct Method Testing
Boiler
Fuel Input 100%
+ Air
SteamOutput
Efficiency = Heat addition to Steam x 100
Gross Heat in Fuel
Flue
Gas
Water
100
valuecalorificGrossxratefiringFuel
enthalpy)waterfeedenthalpy(steamxrateflowSteam
xEfficiencyBoiler


Indirect Method Testing
Boiler Flue gas sample
Steam Output
Efficiency = 100 – (1+2+3+4+5+6+7+8) (by Indirect Method)
Air
Fuel Input, 100%
1. Dry Flue gas loss
2. H2 loss
3. Moisture in fuel
4. Moisture in air
5. CO loss
7. Fly ash loss
6. Surface loss
8. Bottom ash loss
Water
Blow down
Instruments used for Boiler Performance
Assessment.
Instrument Type Measurements
Flue gas
analyzer
Portable or fixed % CO2 , O2 and CO
Temperature
indicator
Thermocouple,
liquid in glass
Fuel temperature, flue gas
temperature, combustion
air temperature, boiler
surface temperature,
steam temperature
Draft gauge Manometer,
differential
pressure
Amount of draft used or
available
TDS meter Conductivity Boiler water TDS, feed
water TDS, make-up water
TDS.
Flow meter As applicable Steam flow, water flow,
fuel flow, air flow
1.Technical specification of boiler
1 Boiler ID code and Make
2 Year of Make
3 Boiler capacity rating
4 Type of Boiler
5 Type of fuel used
6 Maximum fuel flow rate
7 Efficiency by GCV
8 Steam generation pressure &superheat temperature
9 Heat transfer area in m2
10 Is there any waste heat recovery device installed
11 Type of draft
12 Chimney height in metre
2 - Fuel analysis details
Fuel Fired
GCV of fuel
Specific gravity of fuel (Liquid)
Bulk density of fuel (Solid)
Proximate Analysis Date of Test:
1 Fixed carbon %
2 Volatile matter %
3 Ash %
4 Moisture %
Ultimate Analysis Date of Test:
Carbon %
Hydrogen %
Sulphur %
Nitrogen %
Ash %
Moisture %
Oxygen %
Water Analysis Date of Test:
Feed water TDS ppm
Blow down TDS ppm
PH of feed water
PH of blow down
Flue gas Analysis Date of Test:
CO2 %
O2 %
CO %
Flue gas temperature OC
S
.
N
o
T
i
m
e
Ambient air Fuel Feed water Steam Flue gas
analysis
Surface
Temp of
boiler, oC
Dry
bulb
Temp,
oC
Wet
Bulb
Temp,
oC
Flow
Rate,
kg/hr
T
e
m
p
o
C
Flow
rate,
m3/hr
T
e
m
p
o
C
Flo
w
rat
e,
m3
/hr
Pr
ess
ur
e
kg
/c
m2
g
T
e
m
p
o
C
O
2
%
C
O
2
%
C
O
%
T
e
m
p
0
C
1
.
2
.
3
.
4
.
5
.
6
.
7
.
8
.
4. Format sheet for boiler efficiency testing
Date: ………………… Boiler Code No. …………………
Boiler Supervisor Energy Manager Energy Auditor
Fuel firing rate = 5599.17 kg/hr
Steam generation rate = 21937.5 kg/hr
Steam pressure = 43 kg/cm2
(g)
Steam temperature = 377 o
C
Feed water temperature = 96 o
C
%CO2 in Flue gas = 14
%CO in flue gas = 0.55
Average flue gas temperature = 190 o
C
Ambient temperature = 31 o
C
Humidity in ambient air = 0.0204 kg / kg dry air
Surface temperature of boiler = 70 o
C
Wind velocity around the boiler = 3.5 m/s
Total surface area of boiler = 90 m2
GCV of Bottom ash = 800 kCal/kg
GCV of fly ash = 452.5 kCal/kg
Ratio of bottom ash to fly ash = 90:10
Fuel Analysis (in %)
Ash content in fuel = 8.63
Moisture in coal = 31.6
Carbon content = 41.65
Hydrogen content = 2.0413
Nitrogen content = 1.6
Oxygen content = 14.48
GCV of Coal = 3501 kCal/kg
The data collected are
for a boiler using coal
as the fuel.
Find out the boiler
efficiency by indirect
method.
Boiler efficiency by indirect method
Step – 1 Find theoretical air
requirement
Theoretical air required for
complete combustion
= [(11.43 x C) + {34.5 x (H2 – O2/8)} + (4.32 x S)] /
100 kg/kg of coal
= [(11.43 x 41.65) + {34.5 x (2.0413 – 14.48/8)} +
(4.32 x 0)] / 100
= 4.84 kg / kg of coal
Step – 2 Find theoretical CO2 %
% CO2 at theoretical condition
( CO2 )t
=
Moles of C
Moles of N2 + Moles of C
Where,
Moles of N2 =
4.84 x 77/100 0.016
+ = 0.1332
28 28
Where moles of C = 0.4165/12 = 0.0347
( CO2 )t =
0.0347
0.1332 + 0.0347
= 20.67
Step – 3 To find Excess air
supplied
Actual CO2 measured in flue gas = 14.0%
% Excess air supplied (EA) = 7900 x [ ( CO2)t – (CO2)a]
(CO2)a x [100 – (CO2)t ]
= 7900 x [20.67 – 14 ]
14a x [100 – 20.67]
= 47.44 %
Step – 4 to find actual mass of air supplied
Actual mass of air supplied = {1 + EA/100} x theoretical air
= {1 + 47.44/100} x 4.84
= 7.13 kg/kg of coal
Step –5 to find actual mass of dry flue gas
Mass of dry flue gas consists of Mass of CO2 +Mass of N2 content in the fuel+ Mass
of N2 in the combustion air supplied + Mass of
oxygen in combustion air supplied
Mass of dry flue gas =
0.4165 x 44 7.13 x 77 (7.13-4.84) x 23
+ 0.016 + +
12 100 100
= 7.562 kg / kg of coal
Step – 6 to find all losses
1. % Heat loss in dry flue gas (L1) = m x cp x (Tf – Ta )
x 100
GCV of fuel
=
7.562 x 0.23 x (190 – 31)
x 100
3501
L1 = 7.89 %
2. % Heat loss due to formation
of water from H2 in fuel (L2)
= 9 x H2 x {584 + Cp (Tf – Ta )}
x 100
GCV of fuel
=
9 x .02041 x {584 + 0.45(190-31)}
x 100
3501
L2 = 3.44 %
3. % Heat loss due to moisture in
fuel (L3)
=
M x {584 + Cp ( Tf – Ta )}
X 100
GCV of fuel
=
0.316 x {584 + 0.45 ( 190 – 31) }
x 100
3501
L3 = 5.91 %
4. % Heat loss due to moisture in
air (L4)
=
AAS x humidity x Cp x (Tf – Ta ) x 100
GCV of fuel
=
7.13 x 0.0204 x 0.45 x (190 – 31) x 100
3501
L4 = 0.29 %
5. % Heat loss due to partial
conversion of C to CO (L5)
=
%CO x %C 5744
x x 100
% CO + (% CO2)a GCV of fuel
=
0.55 x 0.4165 5744
x x 100
0.55 + 14 3501
L5 = 2.58 %
6. Heat loss due to radiation and
convection (L6)
= 0.548 x [ (343/55.55)4
– (304/55.55)4
] + 1.957 x
(343 - 304)1.25
x sq.rt of [(196.85 x 3.5 + 68.9) /
68.9]
= 633.3 w/m2
= 633.3 x 0.86
= 544.64 kCal / m2
Total radiation and convection
loss per hour
= 544.64 x 90
= 49017.6 kCal
% radiation and convection loss = 49017.6 x 100
3501 x 5591.17
L6 = 0.25 %
7. % Heat loss due to unburnt in fly ash
% Ash in coal = 8.63
Ratio of bottom ash to fly ash = 90:10
GCV of fly ash = 452.5 kCal/kg
Amount of fly ash in 1 kg of coal = 0.1 x 0.0863
= 0.00863 kg
Heat loss in fly ash = 0.00863 x 452.5
= 3.905 kCal / kg of coal
% heat loss in fly ash = 3.905 x 100 / 3501
L7 = 0.11 %
8. % Heat loss due to unburnt in fly ash
GCV of bottom ash = 800 kCal/kg
Amount of bottom ash in 1 kg of
coal
= 0.9 x 0.0863
= 0.077 kg
Heat loss in bottom ash = 0.077 x 800
= 62.136 kCal/kg of coal
% Heat loss in bottom ash = 62.136 x 100 / 3501
L8 = 1.77 %
Boiler efficiency by indirect
method
= 100 – (L1+ L2+ L3+ L4+ L5+ L6+ L7+ L8)
= 100-(7.89 + 3.44+ 5.91+ 0.29+ 2.58+ 0.25+
0.11+1.77)
= 100-22.24
= 77.76 %
Summary of Heat Balance for Coal Fired Boiler
Input/Output Parameter kCal / kg of
coal
% loss
Heat Input = 3501 100
Losses in boiler
1. Dry flue gas, L1 = 276.23 7.89
2. Loss due to hydrogen in fuel, L2 = 120.43 3.44
3. Loss due to moisture in fuel, L3 = 206.91 5.91
4. Loss due to moisture in air, L4 = 10.15 0.29
5. Partial combustion of C to CO, L5 = 90.32 2.58
6. Surface heat losses, L6 = 8.75 0.25
7. Loss due to Unburnt in fly ash, L7 = 3.85 0.11
8. Loss due to Unburnt in bottom ash,
L8
= 61.97 1.77
Boiler Efficiency = 100 – (L1 + L2+ L3+ L4+ L5+ L6+ L7+ L8) = 77.76 %
Factors Affecting Boiler
Performance
• Periodical cleaning of boilers
• Periodical soot blowing
• Proper water treatment programme and blow down
control
• Draft control
• Excess air control
• Percentage loading of boiler
• Steam generation pressure and temperature
• Boiler insulation
• Quality of fuel
1 de 22

Recomendados

210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rateManohar Tatwawadi
1.8K visualizações39 slides
Cooling TowerCooling Tower
Cooling TowerAlexander Nootens
3.4K visualizações11 slides
Closed feed water heaters :)Closed feed water heaters :)
Closed feed water heaters :)JhePoi Santos
32.9K visualizações20 slides
boilersboilers
boilersSaurabh Kumar
1.2K visualizações27 slides

Mais conteúdo relacionado

Mais procurados

Boilers ppt (energy conversion)Boilers ppt (energy conversion)
Boilers ppt (energy conversion)Dinesh Panchal
140 visualizações70 slides
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERGopi Chand
45.4K visualizações42 slides
Steam boilerSteam boiler
Steam boilerAshish Bandewar
5.6K visualizações147 slides

Mais procurados(20)

Heat rate of coal fired power plantHeat rate of coal fired power plant
Heat rate of coal fired power plant
Dr. Koteswara Rao Pothala MBA, PMP,FIE45.1K visualizações
Energy performance assessment of boilersEnergy performance assessment of boilers
Energy performance assessment of boilers
Utsav Jain12.2K visualizações
Brayton cycle (Gas Cycle)-IntroductionBrayton cycle (Gas Cycle)-Introduction
Brayton cycle (Gas Cycle)-Introduction
Hashim Hasnain Hadi658 visualizações
Boilers ppt (energy conversion)Boilers ppt (energy conversion)
Boilers ppt (energy conversion)
Dinesh Panchal140 visualizações
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZER
Gopi Chand45.4K visualizações
Steam boilerSteam boiler
Steam boiler
Ashish Bandewar5.6K visualizações
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plant
SHIVAJI CHOUDHURY23.4K visualizações
Boiler efficiency by loss MethodBoiler efficiency by loss Method
Boiler efficiency by loss Method
Rajeev Saini13.3K visualizações
Feedwater heaters in thermal power plantsFeedwater heaters in thermal power plants
Feedwater heaters in thermal power plants
SHIVAJI CHOUDHURY74K visualizações
Design of Methanol Water Distillation Column  Design of Methanol Water Distillation Column
Design of Methanol Water Distillation Column
Rita EL Khoury9K visualizações
210 MW BHEL Turbine Cycle Heat Balance210 MW BHEL Turbine Cycle Heat Balance
210 MW BHEL Turbine Cycle Heat Balance
Manohar Tatwawadi1.4K visualizações
Burner Design, Operation and Maintenance on Ammonia PlantsBurner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia Plants
Gerard B. Hawkins11.8K visualizações
Deaerator Calculations.pdfDeaerator Calculations.pdf
Deaerator Calculations.pdf
selvam9007981.5K visualizações
Boiler equipmentsBoiler equipments
Boiler equipments
Rochdi Taieb7.4K visualizações
Acutal Cycles and Their Analysis - Unit-IAcutal Cycles and Their Analysis - Unit-I
Acutal Cycles and Their Analysis - Unit-I
S.Vijaya Bhaskar14.1K visualizações
A new approach to improving heater efficiencyA new approach to improving heater efficiency
A new approach to improving heater efficiency
Ashutosh Garg2.6K visualizações
Steam Reforming - (ATM) Approach to EquilibriumSteam Reforming - (ATM) Approach to Equilibrium
Steam Reforming - (ATM) Approach to Equilibrium
Gerard B. Hawkins22.3K visualizações
Calculation of Turbine EfficiencyCalculation of Turbine Efficiency
Calculation of Turbine Efficiency
Jahanzeb Khan15.3K visualizações
Air Heater and PF Boiler Performance IndicesAir Heater and PF Boiler Performance Indices
Air Heater and PF Boiler Performance Indices
Manohar Tatwawadi4.8K visualizações
SYNGAS Process IntegrationSYNGAS Process Integration
SYNGAS Process Integration
Gerard B. Hawkins6.4K visualizações

Similar a Assessment of boiler performance

heat ppt.pptxheat ppt.pptx
heat ppt.pptxGaurankamoran1
49 visualizações23 slides
Combustion CalculationsCombustion Calculations
Combustion CalculationsAhsanN2
129 visualizações25 slides

Similar a Assessment of boiler performance(20)

Basics of Thermal Energy management.pptBasics of Thermal Energy management.ppt
Basics of Thermal Energy management.ppt
ssuser2023f041 visualizações
Condition Monitoring of electrical machine Condition Monitoring of electrical machine
Condition Monitoring of electrical machine
Molla Morshad178 visualizações
heat ppt.pptxheat ppt.pptx
heat ppt.pptx
Gaurankamoran149 visualizações
Combustion CalculationsCombustion Calculations
Combustion Calculations
AhsanN2129 visualizações
Fired Heater Efficiency GuideFired Heater Efficiency Guide
Fired Heater Efficiency Guide
justinforth11.9K visualizações
312 r.j.basavaraj312 r.j.basavaraj
312 r.j.basavaraj
4th International Conference on Advances in Energy Research (ICAER) 20131.3K visualizações
Process Calculation - simple distillationProcess Calculation - simple distillation
Process Calculation - simple distillation
Chandran Udumbasseri2.2K visualizações
HR.pptxHR.pptx
HR.pptx
vishal laddha10 visualizações
3193-292321-BOILER_EFFICIENCY.pptx3193-292321-BOILER_EFFICIENCY.pptx
3193-292321-BOILER_EFFICIENCY.pptx
YADIIRWANTO4 visualizações
Combustion and fulesCombustion and fules
Combustion and fules
MattSmith321834131 visualizações
Fuel and combustionFuel and combustion
Fuel and combustion
Raju Mirdha20.7K visualizações
mel725-37.pptmel725-37.ppt
mel725-37.ppt
SaravananKumar2646952 visualizações
Experimental and Process Modelling Study of Integration of a Micro-turbine wi...Experimental and Process Modelling Study of Integration of a Micro-turbine wi...
Experimental and Process Modelling Study of Integration of a Micro-turbine wi...
UK Carbon Capture and Storage Research Centre597 visualizações
Energy audit  boiler and steam linesEnergy audit  boiler and steam lines
Energy audit boiler and steam lines
Rohil Kumar1.2K visualizações
Energy Efficiency of Industrial UtilitiesEnergy Efficiency of Industrial Utilities
Energy Efficiency of Industrial Utilities
Pratap Jung Rai1.6K visualizações
Design and balance : Styrene Oxide ProductionDesign and balance : Styrene Oxide Production
Design and balance : Styrene Oxide Production
ARITRA MUKHERJEE2.6K visualizações
Knowledge Sharing.pdfKnowledge Sharing.pdf
Knowledge Sharing.pdf
Akshay Gupta18 visualizações

Mais de Ashish Kumar Jain

Condensate Condensate
Condensate Ashish Kumar Jain
379 visualizações25 slides
Cooling towerCooling tower
Cooling towerAshish Kumar Jain
4.3K visualizações38 slides
Governing systemGoverning system
Governing systemAshish Kumar Jain
610 visualizações41 slides

Mais de Ashish Kumar Jain(20)

Proximate & ultimate analysis of coalProximate & ultimate analysis of coal
Proximate & ultimate analysis of coal
Ashish Kumar Jain5.1K visualizações
Condensate Condensate
Condensate
Ashish Kumar Jain379 visualizações
Belt conveyor-manufacturing & utilizationBelt conveyor-manufacturing & utilization
Belt conveyor-manufacturing & utilization
Ashish Kumar Jain520 visualizações
Cooling towerCooling tower
Cooling tower
Ashish Kumar Jain4.3K visualizações
Permacare RO membrane expertisePermacare RO membrane expertise
Permacare RO membrane expertise
Ashish Kumar Jain313 visualizações
Governing systemGoverning system
Governing system
Ashish Kumar Jain610 visualizações
Generator capability curve Generator capability curve
Generator capability curve
Ashish Kumar Jain1.6K visualizações
Bhel STEAM safety valve_1700_seriesBhel STEAM safety valve_1700_series
Bhel STEAM safety valve_1700_series
Ashish Kumar Jain2.8K visualizações
Deaerator  -thermal power plantsDeaerator  -thermal power plants
Deaerator -thermal power plants
Ashish Kumar Jain1.6K visualizações
Chiller absorption machine  working principleChiller absorption machine  working principle
Chiller absorption machine working principle
Ashish Kumar Jain453 visualizações
Belt Conveyor SystemBelt Conveyor System
Belt Conveyor System
Ashish Kumar Jain6.4K visualizações
STEAM TURBINES Governing System & TROUBLE SHOOTINGSTEAM TURBINES Governing System & TROUBLE SHOOTING
STEAM TURBINES Governing System & TROUBLE SHOOTING
Ashish Kumar Jain10.1K visualizações
High speed balancing of turbine rotorsHigh speed balancing of turbine rotors
High speed balancing of turbine rotors
Ashish Kumar Jain5.5K visualizações
Excel Tips in computersExcel Tips in computers
Excel Tips in computers
Ashish Kumar Jain119 visualizações
Thermal Power Plant   -   Emergency situations Thermal Power Plant   -   Emergency situations
Thermal Power Plant - Emergency situations
Ashish Kumar Jain4.9K visualizações
 Boiler -Emergency Handling Boiler -Emergency Handling
Boiler -Emergency Handling
Ashish Kumar Jain3.9K visualizações
Cogeneration power plantCogeneration power plant
Cogeneration power plant
Ashish Kumar Jain2.9K visualizações
Rankine cycleRankine cycle
Rankine cycle
Ashish Kumar Jain2.9K visualizações
Thermax IR CFBC BOILER                U BEAM TYPEThermax IR CFBC BOILER                U BEAM TYPE
Thermax IR CFBC BOILER U BEAM TYPE
Ashish Kumar Jain6.3K visualizações

Último

IEC 61850 Technical Overview.pdfIEC 61850 Technical Overview.pdf
IEC 61850 Technical Overview.pdfssusereeea97
5 visualizações177 slides
MSA Website Slideshow (16).pdfMSA Website Slideshow (16).pdf
MSA Website Slideshow (16).pdfmsaucla
26 visualizações8 slides
Deutsch CrimpingDeutsch Crimping
Deutsch CrimpingIwiss Tools Co.,Ltd
15 visualizações7 slides

Último(20)

IEC 61850 Technical Overview.pdfIEC 61850 Technical Overview.pdf
IEC 61850 Technical Overview.pdf
ssusereeea975 visualizações
MSA Website Slideshow (16).pdfMSA Website Slideshow (16).pdf
MSA Website Slideshow (16).pdf
msaucla26 visualizações
Codes and Conventions.pptxCodes and Conventions.pptx
Codes and Conventions.pptx
IsabellaGraceAnkers6 visualizações
Activated sludge process .pdfActivated sludge process .pdf
Activated sludge process .pdf
8832RafiyaAltaf6 visualizações
Deutsch CrimpingDeutsch Crimping
Deutsch Crimping
Iwiss Tools Co.,Ltd15 visualizações
Stone Masonry and Brick Masonry.pdfStone Masonry and Brick Masonry.pdf
Stone Masonry and Brick Masonry.pdf
Mohammed Abdullah Laskar19 visualizações
Electronic Devices - Integrated Circuit.pdfElectronic Devices - Integrated Circuit.pdf
Electronic Devices - Integrated Circuit.pdf
booksarpita10 visualizações
Sanitary Landfill- SWM.pptxSanitary Landfill- SWM.pptx
Sanitary Landfill- SWM.pptx
Vinod Nejkar5 visualizações
Wire Cutting & StrippingWire Cutting & Stripping
Wire Cutting & Stripping
Iwiss Tools Co.,Ltd6 visualizações
Pointers.pptxPointers.pptx
Pointers.pptx
Ananthi Palanisamy62 visualizações
IWISS Catalog 2022IWISS Catalog 2022
IWISS Catalog 2022
Iwiss Tools Co.,Ltd23 visualizações
What is Unit TestingWhat is Unit Testing
What is Unit Testing
Sadaaki Emura21 visualizações
Wire RopeWire Rope
Wire Rope
Iwiss Tools Co.,Ltd8 visualizações
SEMI CONDUCTORSSEMI CONDUCTORS
SEMI CONDUCTORS
pavaniaalla200516 visualizações
Dynamics of Hard-Magnetic Soft MaterialsDynamics of Hard-Magnetic Soft Materials
Dynamics of Hard-Magnetic Soft Materials
Shivendra Nandan13 visualizações
PlumbingPlumbing
Plumbing
Iwiss Tools Co.,Ltd11 visualizações
SWM L15-L28_drhasan (Part 2).pdfSWM L15-L28_drhasan (Part 2).pdf
SWM L15-L28_drhasan (Part 2).pdf
MahmudHasan74787028 visualizações
Extensions of Time - Contract ManagementExtensions of Time - Contract Management
Extensions of Time - Contract Management
brainquisitive14 visualizações

Assessment of boiler performance

  • 1. ENERGY PERFORMANCE ASSESSMENT OF BOILERS ASHISH KUMAR JAIN
  • 2. Performance Terms and Definitions Heat output Heat Input Boiler Efficiency,  = Heat in steam output (kCals) Heat in Fuel Input (kCals) Quantity of Steam Generation Quantity of fuel Consumption Evaporation Ratio = The efficiency of a boiler is expressed as the % of useful heat available from the total energy available by burning the fuel. This is expressed on the basis of gross calorific value (GCV) .
  • 3. Standards British standards, BS845: 1987 This describes the methods and conditions under which a boiler should be tested.Boiler should be operated under steady load conditions (generally full load) for a period of one hour before taking reading ASME Standard: PTC-4-1 Power Test Code for Steam Generating Units q Part One: Direct method (also called as Input -output method) q Part Two: Indirect method (also called as Heat loss method) IS 8753: Indian Standard for Boiler Efficiency Testing All standards do not include blow down as a loss in the efficiency determination process.
  • 4. Direct Method Testing Boiler Fuel Input 100% + Air SteamOutput Efficiency = Heat addition to Steam x 100 Gross Heat in Fuel Flue Gas Water 100 valuecalorificGrossxratefiringFuel enthalpy)waterfeedenthalpy(steamxrateflowSteam xEfficiencyBoiler  
  • 5. Indirect Method Testing Boiler Flue gas sample Steam Output Efficiency = 100 – (1+2+3+4+5+6+7+8) (by Indirect Method) Air Fuel Input, 100% 1. Dry Flue gas loss 2. H2 loss 3. Moisture in fuel 4. Moisture in air 5. CO loss 7. Fly ash loss 6. Surface loss 8. Bottom ash loss Water Blow down
  • 6. Instruments used for Boiler Performance Assessment. Instrument Type Measurements Flue gas analyzer Portable or fixed % CO2 , O2 and CO Temperature indicator Thermocouple, liquid in glass Fuel temperature, flue gas temperature, combustion air temperature, boiler surface temperature, steam temperature Draft gauge Manometer, differential pressure Amount of draft used or available TDS meter Conductivity Boiler water TDS, feed water TDS, make-up water TDS. Flow meter As applicable Steam flow, water flow, fuel flow, air flow
  • 7. 1.Technical specification of boiler 1 Boiler ID code and Make 2 Year of Make 3 Boiler capacity rating 4 Type of Boiler 5 Type of fuel used 6 Maximum fuel flow rate 7 Efficiency by GCV 8 Steam generation pressure &superheat temperature 9 Heat transfer area in m2 10 Is there any waste heat recovery device installed 11 Type of draft 12 Chimney height in metre
  • 8. 2 - Fuel analysis details Fuel Fired GCV of fuel Specific gravity of fuel (Liquid) Bulk density of fuel (Solid) Proximate Analysis Date of Test: 1 Fixed carbon % 2 Volatile matter % 3 Ash % 4 Moisture %
  • 9. Ultimate Analysis Date of Test: Carbon % Hydrogen % Sulphur % Nitrogen % Ash % Moisture % Oxygen % Water Analysis Date of Test: Feed water TDS ppm Blow down TDS ppm PH of feed water PH of blow down Flue gas Analysis Date of Test: CO2 % O2 % CO % Flue gas temperature OC
  • 10. S . N o T i m e Ambient air Fuel Feed water Steam Flue gas analysis Surface Temp of boiler, oC Dry bulb Temp, oC Wet Bulb Temp, oC Flow Rate, kg/hr T e m p o C Flow rate, m3/hr T e m p o C Flo w rat e, m3 /hr Pr ess ur e kg /c m2 g T e m p o C O 2 % C O 2 % C O % T e m p 0 C 1 . 2 . 3 . 4 . 5 . 6 . 7 . 8 . 4. Format sheet for boiler efficiency testing Date: ………………… Boiler Code No. ………………… Boiler Supervisor Energy Manager Energy Auditor
  • 11. Fuel firing rate = 5599.17 kg/hr Steam generation rate = 21937.5 kg/hr Steam pressure = 43 kg/cm2 (g) Steam temperature = 377 o C Feed water temperature = 96 o C %CO2 in Flue gas = 14 %CO in flue gas = 0.55 Average flue gas temperature = 190 o C Ambient temperature = 31 o C Humidity in ambient air = 0.0204 kg / kg dry air Surface temperature of boiler = 70 o C Wind velocity around the boiler = 3.5 m/s Total surface area of boiler = 90 m2 GCV of Bottom ash = 800 kCal/kg GCV of fly ash = 452.5 kCal/kg Ratio of bottom ash to fly ash = 90:10 Fuel Analysis (in %) Ash content in fuel = 8.63 Moisture in coal = 31.6 Carbon content = 41.65 Hydrogen content = 2.0413 Nitrogen content = 1.6 Oxygen content = 14.48 GCV of Coal = 3501 kCal/kg The data collected are for a boiler using coal as the fuel. Find out the boiler efficiency by indirect method.
  • 12. Boiler efficiency by indirect method Step – 1 Find theoretical air requirement Theoretical air required for complete combustion = [(11.43 x C) + {34.5 x (H2 – O2/8)} + (4.32 x S)] / 100 kg/kg of coal = [(11.43 x 41.65) + {34.5 x (2.0413 – 14.48/8)} + (4.32 x 0)] / 100 = 4.84 kg / kg of coal
  • 13. Step – 2 Find theoretical CO2 % % CO2 at theoretical condition ( CO2 )t = Moles of C Moles of N2 + Moles of C Where, Moles of N2 = 4.84 x 77/100 0.016 + = 0.1332 28 28 Where moles of C = 0.4165/12 = 0.0347 ( CO2 )t = 0.0347 0.1332 + 0.0347 = 20.67
  • 14. Step – 3 To find Excess air supplied Actual CO2 measured in flue gas = 14.0% % Excess air supplied (EA) = 7900 x [ ( CO2)t – (CO2)a] (CO2)a x [100 – (CO2)t ] = 7900 x [20.67 – 14 ] 14a x [100 – 20.67] = 47.44 %
  • 15. Step – 4 to find actual mass of air supplied Actual mass of air supplied = {1 + EA/100} x theoretical air = {1 + 47.44/100} x 4.84 = 7.13 kg/kg of coal Step –5 to find actual mass of dry flue gas Mass of dry flue gas consists of Mass of CO2 +Mass of N2 content in the fuel+ Mass of N2 in the combustion air supplied + Mass of oxygen in combustion air supplied Mass of dry flue gas = 0.4165 x 44 7.13 x 77 (7.13-4.84) x 23 + 0.016 + + 12 100 100 = 7.562 kg / kg of coal
  • 16. Step – 6 to find all losses 1. % Heat loss in dry flue gas (L1) = m x cp x (Tf – Ta ) x 100 GCV of fuel = 7.562 x 0.23 x (190 – 31) x 100 3501 L1 = 7.89 %
  • 17. 2. % Heat loss due to formation of water from H2 in fuel (L2) = 9 x H2 x {584 + Cp (Tf – Ta )} x 100 GCV of fuel = 9 x .02041 x {584 + 0.45(190-31)} x 100 3501 L2 = 3.44 % 3. % Heat loss due to moisture in fuel (L3) = M x {584 + Cp ( Tf – Ta )} X 100 GCV of fuel = 0.316 x {584 + 0.45 ( 190 – 31) } x 100 3501 L3 = 5.91 %
  • 18. 4. % Heat loss due to moisture in air (L4) = AAS x humidity x Cp x (Tf – Ta ) x 100 GCV of fuel = 7.13 x 0.0204 x 0.45 x (190 – 31) x 100 3501 L4 = 0.29 % 5. % Heat loss due to partial conversion of C to CO (L5) = %CO x %C 5744 x x 100 % CO + (% CO2)a GCV of fuel = 0.55 x 0.4165 5744 x x 100 0.55 + 14 3501 L5 = 2.58 %
  • 19. 6. Heat loss due to radiation and convection (L6) = 0.548 x [ (343/55.55)4 – (304/55.55)4 ] + 1.957 x (343 - 304)1.25 x sq.rt of [(196.85 x 3.5 + 68.9) / 68.9] = 633.3 w/m2 = 633.3 x 0.86 = 544.64 kCal / m2 Total radiation and convection loss per hour = 544.64 x 90 = 49017.6 kCal % radiation and convection loss = 49017.6 x 100 3501 x 5591.17 L6 = 0.25 %
  • 20. 7. % Heat loss due to unburnt in fly ash % Ash in coal = 8.63 Ratio of bottom ash to fly ash = 90:10 GCV of fly ash = 452.5 kCal/kg Amount of fly ash in 1 kg of coal = 0.1 x 0.0863 = 0.00863 kg Heat loss in fly ash = 0.00863 x 452.5 = 3.905 kCal / kg of coal % heat loss in fly ash = 3.905 x 100 / 3501 L7 = 0.11 % 8. % Heat loss due to unburnt in fly ash GCV of bottom ash = 800 kCal/kg Amount of bottom ash in 1 kg of coal = 0.9 x 0.0863 = 0.077 kg Heat loss in bottom ash = 0.077 x 800 = 62.136 kCal/kg of coal % Heat loss in bottom ash = 62.136 x 100 / 3501 L8 = 1.77 %
  • 21. Boiler efficiency by indirect method = 100 – (L1+ L2+ L3+ L4+ L5+ L6+ L7+ L8) = 100-(7.89 + 3.44+ 5.91+ 0.29+ 2.58+ 0.25+ 0.11+1.77) = 100-22.24 = 77.76 % Summary of Heat Balance for Coal Fired Boiler Input/Output Parameter kCal / kg of coal % loss Heat Input = 3501 100 Losses in boiler 1. Dry flue gas, L1 = 276.23 7.89 2. Loss due to hydrogen in fuel, L2 = 120.43 3.44 3. Loss due to moisture in fuel, L3 = 206.91 5.91 4. Loss due to moisture in air, L4 = 10.15 0.29 5. Partial combustion of C to CO, L5 = 90.32 2.58 6. Surface heat losses, L6 = 8.75 0.25 7. Loss due to Unburnt in fly ash, L7 = 3.85 0.11 8. Loss due to Unburnt in bottom ash, L8 = 61.97 1.77 Boiler Efficiency = 100 – (L1 + L2+ L3+ L4+ L5+ L6+ L7+ L8) = 77.76 %
  • 22. Factors Affecting Boiler Performance • Periodical cleaning of boilers • Periodical soot blowing • Proper water treatment programme and blow down control • Draft control • Excess air control • Percentage loading of boiler • Steam generation pressure and temperature • Boiler insulation • Quality of fuel