  1. 1. Group Name ID NO • 1. Behailu haile 422/09 • 2. Asefa Hadush 433/09 • 3. Abreham Atsbeha 370/09 • 4. Agazi G/Yesuse 376/09 • 5. Alemsegd Megrsa 273/09 • 6. Almaz Germa 374/09
  2. 2. ADDIS COLLEGE FACULTY OF CIVIL ENGINEERING & CONSTRUCTION MANAGEMENT DEPARTMENT OF CIVIL ENGINEERING Analysis and comparison of wind effect on different types of the roof structure
  3. 3. INTRODUCTION Wind forces are variable loads which act directly on the internal and external surface of structures The response of a structure to the variable action of wind can be separated in to two components, 1. Background component which involves static deflection of the structure under the wind pressure 2. Resonant component , on the other hand, involves dynamic vibration of the structure in response to changes in wind pressure.
  4. 4. INTRODUCTION In most structures the resonant component is relatively small and structural response to wind forces is treated using static methods of analysis alone.
  5. 5. INTRODUCTION • Choosing the most appropriate type of roofs depends immense on the conditions of the place where the buildings are constructed is important. • But buildings’ functions have also produced typical roof shapes. • Different roof types can be combined, but this often produces a complicated geometry of details. • Simple structures are therefore preferable, to avoid leakage. • The main distinction in roof types is between pitched and flat roofs;
  6. 6. INTRODUCTION • A flat roof:-has a pitch of zero in either instance; all other roofs are pitched. • Pitched roof:- pitch is the steepness of a roof expressed as a ratio of pinch rise per horizontal foot, or as the angle in degrees, • Mono pitch roofs:- has a single rafter and is a right angle truss used to form lean-to roofs or single pitched roofs.
  7. 7. INTRODUCTION • Dou pitch roof:- just as the name suggests, have two different pitches on each side of the roof. • Hipped roof:- is a type of roof where all sides slope downwards to the walls, by definition (hipped roof is with steeply pitched slopes rising to a peak).
  8. 8. RESEARCH METHODOLOGY • Method of analysis is conducted using software analysis, Ethiopian and Euro codes are the main guides for our research. • Most commonly applicable roof types are compared. • The roof types are analyzed independently then each output is compared. • Similar material and literatures are used for roofs under analysis.
  9. 9. RESEARCH METHODOLOGY •The thesis help us to practice some software
  10. 10. Study Area Description • The study area is Adama town and the analysis used to other towns(places) having similar character. • Adama varies from ground elevations of 1,595masl to 1,740m asl. • Areas with higher altitudes are found from the central to the northern and on the southern verges of the town. • Therefore the average altitude is 1712m asl.
  11. 11. location map of Adama town
  12. 12. 1.4.1 General Objective • The general objective of this study is to examine the extent of wind load on roofs structure and evaluate its impact on different types of roofs in the study area, having altitude of 1712m, Ethiopia like Adama.
  13. 13. Specific Objective  To analyze wind load effects on various roof types;  To compare and contrast wind load effect on different roof types ;  To identify safe and economical roof structures.
  14. 14. Reference wind velocity • The reference wind velocity for a locality is defined as the mean wind velocity at 10m above farmland averaged over a period of 10 minutes with a return period of 50 years • Vref = CDIRCTEMCALTVref, 0 • Where Vref,0 is the basic reference wind velocity 10m above sea level
  15. 15. • CDIR Direction factor Allows for the orientation of the structure in relation to the direction of the prevailing wind • CTEM Seasonal variations in temporary structures The seasonal variation factor, CTEM, may be applied to structures of a temporary nature which are exposed to wind for only part of a given year • CALT Altitude factor allows for the altitude of the site on which the structure is located. Wind speeds tend to be greater in sites located at high altitudes.
  16. 16. Reference wind velocity • Vref=Cdir*Ctemp*Calt*Vref=22m/s for Ethiopia as per ECS 145 2015 • Assuming Adama altitude in Ethiopia at 1712m Altitude above MSL => ρ=0.98kg/m3. @ 20 0C By interpolation • qp = ρ/2* Vref 2 The basic velocit preasure in our case it is 0.237KPa • The wind pressure acting on the external surface of a structure is function of the reference wind pressure which is given by:
  17. 17. Exposure coefficient • The exposure coefficient takes account of the variation from the reference wind velocity due to the roughness around the structure, • the local topography and the height of the structure above ground level is considered • In our case the height of the building is 35.5m
  18. 18. Exposure coefficient • Where Cr and Ct are roughness and topography coefficients respectively and kT is a terrain factor(find in table 3.2 EBCS 1) •Our site is categorized under Category 3 as per The terrain categories are illustrated in Annex A.1. ..CES 145 •Which regular cover of vegetation or buildings or with isolated obstacles with separations of maximum 20 obstacle eights (such as villages, suburban terrain, permanent forest) • KT[Terrain Factor]=0.22, Zo=0.3m , Zmin=5m
  19. 19. Wind pressure • Wi=qp(z ) * cpi Internal Wind preasure •Where: Cpi = 0.8 or -0.5 for closed buildings with partition wall and openings) ss per ECS 145 • In our case 20150.711*0.8= 0.57KN/m2
  20. 20. • we=qp(z ) * cpe External Wind presure • In our case 0.711Cpe •We take Maximum Cpe from Roof zoning therefore we =2.183KN/m2
  21. 21. compare and contrast wind load effect on different roof types 1. Flat slab roof • Reinforced concrete slab is analysis using wind load and its dead load • The slab is divided in to panels As per ECS 2015 the support conditions are taken in to consideration • Depth of slab and span of slab are determined. • Minimum reinforcement is analyzed
  22. 22. • We use Excel template for slab analysis • Diameter 8 bar average spacing 150 mm and 200mm • Slab thickness 150mm with concrete cover 25mm both sides is Effective and safe
  23. 23. 2. Hipped roof @ 35.5 m
  24. 24. • The topography coefficient, Ct, accounts for the increase in mean wind speed over isolated hills and escarpments. Details for its calculation in such cases are given in EBCS1 (Figure 3.6 and 3.7). For all other situations, Ct may be taken as unity.
  25. 25. External wind pressure • The wind pressure acting on the external surface of a structure is function of the reference wind pressure which is given by: • • Where  = air density (kg/m3) • ref = reference wind velocity (m/s) • The density of air varies with temperature, elevation and the expected atmospheric pressure in the region during a storm. EBCS1 gives a recommended design value of  at 200 C for different altitudes. Table 3.15 EBCS 1
  26. 26. Cont……. • We = ce(ze)cpeqref • cpe(external pressure coefficient) find in EBCS 1 Appendix A
  27. 27. Internal wind pressure • Internal pressure arises due to openings, such as windows, doors and vents, in the cladding. In general, if the windward pane has a greater proportion of opening than the leeward panel, then the interior of the structure is subjected to positive (outward) pressure • wi =ce(zi)cpiqref • Cpi ((internal pressure coefficient) find in EBCS 1 Appendix A) • For buildings with internal partitions the extreme values, cpi = 0.8 and cpi = -0.5, may be used.
  28. 28. • Wind force on structures • The total wind force action on individual zones of clad structures is proportional to the difference in pressure between the external and internal faces. That is: • Fw = (we – wi) Aref
  29. 29. Example 1 • Site altitude 2000 • Suburban or industrial area
  30. 30. • According to EBCS1, Art 3.5.2 • External pressure (We) • We=qrefce(ze)cpe • Where Cpe is the external pressure coefficient derived from Appendix A. • Internal pressure (Wi) • Wi= qref Ce (zi) Cpi • Where • qref =reference mean wind velocity • Ce (ze) =exposure coefficient • z= reference height • Cpe= external pressure coefficient • Cpi= internal pressure coefficient
  31. 31. • Vref=CDIR CTEM CALT Vref,o • According to Section 3.7.2 of EBCS 1 • CDIR=CTEM =CALT=1 and Vref,o=22m/s • Vref=22m/s • According to table 3.15 of EBCS 1 • For altitude 2000 p=0.94Kg/m3 • Table 3.2 EBCS 1 i take terrain categories III(suburban or industrial areas and permanent forests) • KT=0.22 Zo(m)=0.3 Zmin(m)=8
  32. 32. • Z=35m • Form table 3.3 of EBCS 1, the roughness coefficient Cr • 30------1.01 • 35-------? Using liner interpolation • 50------1.13 • Cr=1.042 • • Take the Topography coefficient Ct(z)=1 the area is topographically unaffected • The exposure coefficients Ce(Z) can be simply read from table 3.5 of EBCS 1. • • 30---------------2.29 • 35----------------? Using liner interpolation • 50---------------3 • Ce(Z)= 2.47
  33. 33. • Calculation of Cpe and Cpi • Using Appendix A of section A.2.4 of EBCS 1 h=35m α=tan-(5/24)= 11.770

×