SlideShare a Scribd company logo
1 of 22
Download to read offline
Quick Guide
ZEISS ZEN (blue edition)
ZEISS ZEN (blue edition)
Original Manual
Carl Zeiss Microscopy GmbH
Carl-Zeiss-Promenade 10
07745 Jena
Germany
microscopy@zeiss.com
www.zeiss.com/microscopy
Carl Zeiss Microscopy GmbH
ZEISS Group
Kistlerhofstr. 75
81379 München
Document Name: ZEISS ZEN (blue edition) Quick Guide
Revision: 2
Language: en-US
Effective from: 04/2021
© 2021 Without the prior written consent of ZEISS, this document or any part of it must neither be translated nor reproduced or
transmitted in any form or by any means - including electronic or mechanic methods, by photocopying, recording or by any in-
formation or filing system. The right to make backup-copies for archiving purposes shall remain unaffected thereby. Any viola-
tions may be prosecuted as copyright infringements.
The use of general descriptive names, registered names, trademarks, etc. in this document does not imply that such names are
exempt from the relevant intellectual property laws and regulations and therefore free for general use. This shall also apply if
this is not specifically referred to. Software programs shall entirely remain the property of ZEISS. No program or subsequent up-
grade thereof may be disclosed to any third party, copied or reproduced in any other form without the prior written consent of
ZEISS, even if these copies or reproductions are destined for internal use at the customer's only, the only exception being one
single back-up copy for archiving purposes.
ZEISS reserves the right to make modifications to this document without notice.
​ Inhalt​ ZEISS
Inhalt
1 Welcome ....................................................................................... 4
2 Starting Software.......................................................................... 5
3 User Interface................................................................................ 6
3.1 Title bar...................................................................................................... 6
3.2 Workspace Configuration........................................................................... 7
3.3 Menu bar ................................................................................................... 7
3.4 Tool bar ..................................................................................................... 7
3.5 Left Tool Area ............................................................................................ 8
3.6 Center Screen Area..................................................................................... 9
3.7 Right Tool Area .......................................................................................... 10
3.8 Document bar ............................................................................................ 10
3.9 Status bar................................................................................................... 10
3.9.1 System Messages........................................................................ 12
4 Adjusting Workspace Appearance................................................. 13
4.1 Setting User Language ............................................................................... 13
4.2 Selecting Screen Design.............................................................................. 13
4.3 Adjusting Workspace Zoom........................................................................ 13
4.4 Showing/Hiding Workspace Areas.............................................................. 13
4.5 Undocking/Docking Tool Windows............................................................. 14
4.6 Activating Show All Mode.......................................................................... 14
5 Step by step to the first image ...................................................... 16
5.1 Configuring Microscope Components......................................................... 16
5.2 Acquiring Camera Image............................................................................ 17
5.3 Adding Annotations ................................................................................... 19
5.4 Adjusting Live Image Settings..................................................................... 19
5.5 Creating Manual Scaling............................................................................. 20
6 Closing the Software ..................................................................... 21
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 3
1 Welcome​ ZEISS
1 Welcome
ZEN (blue edition) is a modular image acquisition, processing and analysis software for digital mi-
croscopy. The abbreviation ZEN stands for ZEISS Efficient Navigation and points out that the soft-
ware can be used to control microscopes and imaging systems by ZEISS.
In addition to basic functionality for image acquisition, elementary image processing and annota-
tions and image analysis a lot of optional modules for specific microscopy tasks are available.
With ZEN lite the basic version of the software is available for free. Starting from a basic function-
ality for image acquisition, simple image processing, image analysis and documentation a lot of
optional modules are available for ZEN lite as well. More detailed information is available in the
product brochure.
Disclaimer This product is not intended for use in medical or diagnostic procedures.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 4
2 Starting Software​ ZEISS
2 Starting Software
Prerequisite ü You have switched on the hardware components to be ready for operation.
ü You have installed ZEN (blue edition) on your computer.
1. Double-click on the program icon on your desktop.
2. Alternatively click Start > Carl Zeiss Microscopy > ZEN (blue edition).
à The software starts and displays a loading screen. After a while you see the login screen.
3. Click on the application you want to work with. The available applications depend on your
licenses and system (e.g. if you work with an LSM, only ZEN system and Image Process-
ing are available).
à The software starts. During the program start the hardware settings will be initialized.
Info
Using pre-recorded Images
For using pre-recorded images when starting the software, in the menu Tools > Options >
Startup, the Reload Last Used Documents checkbox must be activated.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 5
3 User Interface | 3.1 Title bar ZEISS
3 User Interface
The software user interface is divided into three main areas.
1 2 3
Fig. 1: User interface
1 Left Tool Area
With the tabs you can access all the main tools for microscope control (Locate Tab), ac-
quisition (Acquisition Tab), image processing (Processing Tab), image analysis (Analysis
Tab), and applications (Applications Tab).
2 Center Screen Area
This area is used to display your images with several image views available. For more in-
formation, see Center Screen Area [} 9].
3 Right Tool Area
Here you find the Images and Documents Tool, the Objective Selection and the Stage
and Focus controls. Additionally system specific tools can be available here (e.g. Definite
Focus and ZEN Connect controls).
3.1 Title bar
Parameter Description
Help icon Activates the "drag & drop“ help function. A question mark ap-
pears beside the mouse pointer. Move the mouse pointer to a
place in the software where you need help. Left-click on the de-
sired location. The online help opens.
Minimize Minimizes the program window.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 6
3 User Interface | 3.2 Workspace Configuration ZEISS
Parameter Description
Maximize Over 2
Screens
Maximizes the program window across 2 screens if available.
This option is only possible if you are working with 2 screens
with the same resolution.
Maximize Maximizes the program window to the main screen.
Restore Down Reduces the program window to any selected size.
Close Closes the program window.
3.2 Workspace Configuration
Fig. 2: Workspace Configuration
Here you find settings to adjust your workspace. Select Light/Dark Design of the user interface
or enlarge the screen with Workspace Zoom slider. You can also save and reload all personal
settings in a workspace configuration. With the Dock all tool windows button in the top
right corner you can easily dock all undocked tools by one click.
3.3 Menu bar
Fig. 3: Menu bar
The menu bar contains all the menus you need for managing, editing, and viewing your projects.
3.4 Tool bar
Fig. 4: Tool Bar
Here you gain quick access to important functions, e.g. saving or opening files. Further right you
find more workspace settings, e.g. Design and Workspace selection. Read how to customize the
Tool bar in chapter Customize toolbar.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 7
3 User Interface | 3.5 Left Tool Area ZEISS
3.5 Left Tool Area
This area contains the main tabs for microscope and camera settings (Locate tab), image acquisi-
tion (Acquisition tab), image processing (Processing tab), and image analysis (Analysis tab). The
main tabs are organized in an order which follows the typical workflow of experiments in bio-
science or material science.
Fig. 5: Left Tool Area
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 8
3 User Interface | 3.6 Center Screen Area ZEISS
3.6 Center Screen Area
The Center Screen Area is structured in 4 areas.
1 2 3 4
Fig. 6: Center Screen Area
1 Document bar
Here you can switch between all your opened documents. For more information, see
Document bar [} 10].
2 Image Views
Area where you can switch between different image views by selecting the correspond-
ing tab in the list. For more information, see also Image views.
3 View Options
Area for general and specific view options. For more information, see also General View
Options.
4 Image Area
Area where images, reports, and tables are displayed.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 9
3 User Interface | 3.7 Right Tool Area ZEISS
3.7 Right Tool Area
This area contains mainly the tools for image and file handling (e.g. Image Gallery) and hardware
control (e.g. Stage / Focus tool). Depending on your system configuration, other tools can be
available. The tools are described in the corresponding chapters of the online help.
3.8 Document bar
Here you see tabs of all open documents. Click on a tab to view the image/document. On the
right end of document bar you find buttons to switch view mode from Exposé to Splitter mode
and further view options (View menu).
Info
A asterisk (*) next to an image/document title indicates that unsaved changes have been
made to this document. Save your pictures/documents from time to time in order to avoid
data loss.
Parameter Description
Exposé Mode
Opens the exposé view mode. For more information, see Exposé
mode.
Splitter Mode
Opens the splitter view mode. For more information, see Splitter
mode.
Options
Displays the options of the view menu. For more information about
the individual options, see View Menu.
3.9 Status bar
The status bar shows important information on the system status:
Parameter Description
Scaling Displays which lateral scaling is currently being used. If you click on
the arrow, the Scaling dialog will be opened. There you have access
to advanced scaling settings and the scaling wizard.
System Informa-
tion
Always shows the latest, currently active process that the system is
performing.
Progress bar Displays the progress of the currently active process. Each new
process added supersedes older still active processes. If you click on
the arrow button, a window opens with a list of all processes in
chronological order. You can stop a process that is running using the
Stop button.
Performance indi-
cators
In this group you will see an overview of the performance of individ-
ual computer components:
§ Free RAM indicates how much physical memory is still available.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 10
3 User Interface | 3.9 Status bar ZEISS
Parameter Description
§ Free HD indicates how much space is still available on the hard
drive onto which the next image is to be acquired (see Tools > Op-
tions > Saving).
§ CPU indicates the usage of the Central Processing Unit.
§ The small status bar provides an overall assessment of the system
usage.
§ GPU indicates the usage of the Graphics Processing Unit by ZEN
and ZEN related services. It is also visualized by a small status bar
on its right.
Note: This GPU indicator is only visible if you your computer has
Microsoft Windows 10 version 1709 or higher.
Info: Double-clicking in the Performance Indicators area opens the
Windows Task Manager.
Frame Rate Indicates the current frame rate in frames per second (fps) used by the
active camera for producing new images. Please note in most cases
that at speeds greater than 100 frames per second, this value cannot
always be accurately determined.
Pixel Value Displays the gray value to the image at the current position of the
mouse pointer. In the case of multichannel images the gray value/
channel is displayed for up to 4 channels.
Position Displays the X/Y position (in pixel coordinates) of the mouse pointer in
the image.
Information (i) If you click on the icon, a window opens with a System Messages
[} 12].
Storage Folder Displays the location where new images are automatically saved. This
path can be changed in the menu Tools > Options > Saving.
Status: Airyscan
Detector Align-
ment
If you click on the arrow the Alignment Tool window opens. See
Airyscan Detector Adjustment.
User Shows the Windows user name of the logged in user.
Time Shows the current Windows system time.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 11
3 User Interface | 3.9 Status bar ZEISS
3.9.1 System Messages
If you right-click on a system message the Copy button will appear. Left-click on Copy button to
copy the message to clipboard. Then paste it into a text file or an E-Mail. The idea behind is that
you can easily send error messages to your support team for example. This copy/paste function
works for all upcoming system messages or error messages within the application as well.
Parameter Description
Information
System information that arises during normal operation. This system
information does not lead to an interruption of the workflow. The in-
formation window is not displayed automatically.
Warnings
Information that requires input from the user, e.g. a prompt to
change a manual microscope component. This information leads to
the information window being shown briefly. However, it closes again
after a few seconds.
Errors
Error messages indicate a malfunction by the system. In this case the
information window opens and remains open. The system requires in-
put from the user in order to continue.
Info
Hundreds of messages can accumulate in the course of a session. A maximum of 300 mes-
sages are displayed. To display messages for a certain category, activate or deactivate the cor-
responding checkboxes.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 12
4 Adjusting Workspace Appearance | 4.1 Setting User Language ZEISS
4 Adjusting Workspace Appearance
4.1 Setting User Language
Info
If the Select Automatically checkbox is activated, the software uses the language which is
set in the system settings of your computer. This is the default setting.
Prerequisite ü You have started the application.
1. Go to Tools > Options dialog.
à In the group Software the entry General is selected.
2. Deactivate the Select Automatically checkbox to select the language manually.
3. Select the user language from the Fixed Language drop-down list.
à A message appears to restart the application.
à Note that the availability of additional languages can differ between software versions.
4. Click OK.
à The Options dialog closes.
5. Exit and restart software.
4.2 Selecting Screen Design
In the upper right corner of the program window under Design you can select a Light or Dark
screen layout . Optionally, you can change the design with the shortcut Ctrl+D.
4.3 Adjusting Workspace Zoom
1. To zoom in or out of the workspace move the slider left or right.
2. To reset the workspace zoom to default click Reset.
4.4 Showing/Hiding Workspace Areas
1. Click Show/Hide to show or hide screen areas.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 13
4 Adjusting Workspace Appearance | 4.5 Undocking/Docking Tool Windows ZEISS
4.5 Undocking/Docking Tool Windows
This function allows you to undock/dock a tool window. An undocked tool window can be posi-
tioned anywhere on the screen.
1. Click Undock to undock a tool window. Once undocked, the tool window can be moved
around by clicking and dragging it on the blue bar.
2. Click Dock to dock a tool window back to its place in the left tool area.
Info
With the dock all tools function in the Workspace Configuration you can globally attach all
undocked tool windows back to the Left Tool Area.
4.6 Activating Show All Mode
1. With the Show All mode deactivated (default setting), only the basic functions of tool win-
dows or view options are shown.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 14
4 Adjusting Workspace Appearance | 4.6 Activating Show All Mode ZEISS
2. To show the advanced settings or expert functions of tool windows or view options, click
Show All.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 15
5 Step by step to the first image | 5.1 Configuring Microscope Components ZEISS
5 Step by step to the first image
5.1 Configuring Microscope Components
This chapter refers to the manual configuration of the microscope components in ZEN lite. All mi-
croscope components definitions will be stored in the meta data of the acquired image.
Prerequisite ü You have selected the Camera tab.
1. Click Microscope Components.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 16
5 Step by step to the first image | 5.2 Acquiring Camera Image ZEISS
à The tool will open. Consider that the button Show all is activated.
2. For Objective select that objective you will use for your acquisitions.
3. Select all other microscope components you will use (i.e. Optovar, Reflector, etc.).
You have successfully configured your microscope components.
Info
If you have activated the Select automatically button in the status bar under Scaling (stan-
dard settings), the scaling will be calculated on the basis of your definitions. If you want to
perform a manual scaling, read the chapter Creating Manual Scaling [} 20].
5.2 Acquiring Camera Image
This topic guides you through acquiring your first camera image with the software.
Prerequisite ü You have connected and configured a microscope camera (i.e. Axiocam 305 color/mono) to
your system.
ü You have started the software.
ü You have configured the microscope components (e.g. objective, camera adapter) und you
are using the automatic or manual scaling.
ü You are on the Camera (ZEN lite only) or Locate tab.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 17
5 Step by step to the first image | 5.2 Acquiring Camera Image ZEISS
ü You see your microscope camera available in the Active Camera section. If not, select the
camera from the list.
1. Position your sample on the microscope and adjust the microscope to see a focused image
through the eyepieces.
2. Adjust the tube slider of the microscope to divert the image to the camera (e.g. 50% cam-
era and 50% eyepieces).
3. Click Live.
à The Live Mode will be activated. In the Center Screen Area you will see the camera
live image. By default the live image shows a cross hair helping to navigate on the speci-
men. In the chapter Adjusting Live Image Settings [} 19] you will learn how to optimize
live image display.
4. Click Set Exposure.
à The exposure time will be automatically determined and set.
5. Click Snap.
You successfully acquired your first image. Save the image in the file system via the File menu |
Save as.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 18
5 Step by step to the first image | 5.3 Adding Annotations ZEISS
Info
If you do not see a focused image, please refocus the specimen on the microscope. You may
activate the focus bar as an additional aid. Right-click in the Center Screen Area to open the
context menu. Select the entry Focus Bar. The focus bar will be shown.
See also
2 Document bar [} 10]
5.3 Adding Annotations
Annotations are the generic term for all the graphics (e.g. rectangle, arrow, scale), measurements,
texts or other metadata (e.g. recording time) that you can add to your image.
Prerequisite ü You have acquired or loaded an image.
1. In the Center Screen Area select Graphics.
2. Click Scale Bar.
à The scale bar will appear directly in the image.
à To edit an annotation (e.g. color, line width) you can right-click on the annotation in the
image and select Format Graphical Elements from the context menu.
3. Click Draw Arrow.
à You can now draw an arrow into the image.
5.4 Adjusting Live Image Settings
Prerequisite ü You have started the Live mode via the Live button and see the camera’s live image in the
Center Screen Area.
ü Under the image area you see the general view options on Dimensions tab, Graphics tab
and Display tab.
1. In the Dimensions tab activate the Range Indicator checkbox. This will mark overexposed
(too bright) areas in the live image in red and underexposed (too dark) areas in blue.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 19
5 Step by step to the first image | 5.5 Creating Manual Scaling ZEISS
2. On the Display tab click 0.45. The display curve will be adapted to a gamma value of 0.45.
This will set the optimum color presentation. If you do not see this button, activate the
Show all mode.
3. Move the controls under the display curve left and right in order to directly adjust the val-
ues for Contrast (Black) 1 , Gamma 2 , and Brightness (White) 3 in the live
image.
1 2 3
Info
With the settings above the display of the live image will be adapted. These settings will also
be transferred to your acquired image. This will not change the camera settings.
5.5 Creating Manual Scaling
Prerequisite ü You have an object micrometer oriented horizontally on the microscope stage.
ü You have selected all definitions for your microscope correctly in the Microscope Compo-
nents tool (ZEN lite only). In our example we use an objective with a 10x magnification.
1. Acquire an image (see Acquiring Camera Image [} 17]) of the scale in your object microme-
ter using the objective to be scaled manually.
2. In the bottom status bar click Scaling. In the Scaling dialog deactivate Select Automati-
cally.
3. In the Create new scaling section, click Interactive Calibration....
à The calibration wizard will appear in the image area.
4. Click Single Reference Line and activate Automatic Line Detection.
5. Draw in the reference line along the scale.
6. Enter the true distance between both scale lines in the calibration wizard. In our example
this is 500 micrometer.
7. Enter a name for the scaling (i.e. Obj 10x) and click Save Scaling.
You performed a manual scaling for your objective. Repeat this sequence for all objectives you will
need a manual scaling for. Always ensure that you did select the correct objective in the tool Mi-
croscope Components and for this performed and selected the matching scaling in the status
bar.
Info
4 The function Automatic Line Detection calculates the theoretical maximum of the refer-
ence line‘s both end points to the closest scale lines in the image. Thus the distance will be
calculated with sub-pixel accuracy.
4 If you have defined a manual scaling for an objective and activate the checkbox Select
Automatically, the software will use the measured scaling instead of the theoretic one.
You will recognize this via the label "Measured" instead of "Theoretic" beside the pixel
size.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 20
6 Closing the Software​ ZEISS
6 Closing the Software
1. Click File > Exit. Alternatively you can use the short cut Alt+F4 or click Close in the pro-
gram bar.
Info
If you have not saved your files, the Save Documents dialog will open before the software
closes. Select the files you want to save or unselect the files you do not want to save.
Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 21
Carl Zeiss Microscopy GmbH
Carl-Zeiss-Promenade 10
07745 Jena
Germany
phone: +49 3641 64 3161
fax: +49 3641 64 3439
info.microscopy@zeiss.com
www.zeiss.com/microscopy
Quick
Guide
ZEISS
ZEN
(blue
edition)
|
en-US
|
Rev.2
Modifications
reserved.

More Related Content

Similar to EN_quick-guide_ZEN-blue-edition_first-steps.pdf

Expert systems&cviptools
Expert systems&cviptoolsExpert systems&cviptools
Expert systems&cviptoolsAli Fayed
 
Expert systems&cviptools
Expert systems&cviptoolsExpert systems&cviptools
Expert systems&cviptoolsAli Fayed
 
10 things group policy preferences does better
10 things group policy preferences does better10 things group policy preferences does better
10 things group policy preferences does betterGol D Roger
 
PVsyst_Tutorials_V7_Grid_Connected.pdf
PVsyst_Tutorials_V7_Grid_Connected.pdfPVsyst_Tutorials_V7_Grid_Connected.pdf
PVsyst_Tutorials_V7_Grid_Connected.pdfFREELANCER
 
Cutviewer mill user guide v3
Cutviewer mill user guide v3Cutviewer mill user guide v3
Cutviewer mill user guide v3benjyanim
 
Die View Users Guide
Die View Users GuideDie View Users Guide
Die View Users GuideStuart Riley
 
Doorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letter
Doorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letterDoorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letter
Doorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letterDarrel Rader
 
Health information system.pdf
Health information system.pdfHealth information system.pdf
Health information system.pdfChristian James
 
Rhino cam nesting_gettingstartedguide
Rhino cam nesting_gettingstartedguideRhino cam nesting_gettingstartedguide
Rhino cam nesting_gettingstartedguideJavier Euler Vilca
 
Manual de rápido do equipamento GC-2010 plus Shmadzu
Manual de rápido do equipamento GC-2010 plus ShmadzuManual de rápido do equipamento GC-2010 plus Shmadzu
Manual de rápido do equipamento GC-2010 plus ShmadzuUFC
 
Iptim
IptimIptim
IptimIptim
 
Fischertechnik designer manual
Fischertechnik designer manualFischertechnik designer manual
Fischertechnik designer manualEduardo Alvarez
 

Similar to EN_quick-guide_ZEN-blue-edition_first-steps.pdf (20)

Expert systems&cviptools
Expert systems&cviptoolsExpert systems&cviptools
Expert systems&cviptools
 
Expert systems&cviptools
Expert systems&cviptoolsExpert systems&cviptools
Expert systems&cviptools
 
10 things group policy preferences does better
10 things group policy preferences does better10 things group policy preferences does better
10 things group policy preferences does better
 
2dmanual v5.0
2dmanual v5.02dmanual v5.0
2dmanual v5.0
 
Nx 7.5 cad
Nx 7.5 cadNx 7.5 cad
Nx 7.5 cad
 
PVsyst_Tutorials_V7_Grid_Connected.pdf
PVsyst_Tutorials_V7_Grid_Connected.pdfPVsyst_Tutorials_V7_Grid_Connected.pdf
PVsyst_Tutorials_V7_Grid_Connected.pdf
 
Cutviewer mill user guide v3
Cutviewer mill user guide v3Cutviewer mill user guide v3
Cutviewer mill user guide v3
 
Die View Users Guide
Die View Users GuideDie View Users Guide
Die View Users Guide
 
Cms instruction 1.0
Cms instruction 1.0Cms instruction 1.0
Cms instruction 1.0
 
Doorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letter
Doorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letterDoorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letter
Doorsng po t_core_workbook_sse_imagev3.3.1_v6moda_final_letter
 
SessionCreatorHelp
SessionCreatorHelpSessionCreatorHelp
SessionCreatorHelp
 
Dbw manual
Dbw manualDbw manual
Dbw manual
 
Health information system.pdf
Health information system.pdfHealth information system.pdf
Health information system.pdf
 
Rhino cam nesting_gettingstartedguide
Rhino cam nesting_gettingstartedguideRhino cam nesting_gettingstartedguide
Rhino cam nesting_gettingstartedguide
 
Manual de rápido do equipamento GC-2010 plus Shmadzu
Manual de rápido do equipamento GC-2010 plus ShmadzuManual de rápido do equipamento GC-2010 plus Shmadzu
Manual de rápido do equipamento GC-2010 plus Shmadzu
 
GIS.XL_manual
GIS.XL_manualGIS.XL_manual
GIS.XL_manual
 
Nx cmm creating_probes_v._8.5
Nx cmm creating_probes_v._8.5Nx cmm creating_probes_v._8.5
Nx cmm creating_probes_v._8.5
 
Iptim
IptimIptim
Iptim
 
Family Tree Explorer Manual
Family Tree Explorer ManualFamily Tree Explorer Manual
Family Tree Explorer Manual
 
Fischertechnik designer manual
Fischertechnik designer manualFischertechnik designer manual
Fischertechnik designer manual
 

More from Tassanee Lerksuthirat

External Grant-Devision of Research-19March2024-KM-IMB
External Grant-Devision of Research-19March2024-KM-IMBExternal Grant-Devision of Research-19March2024-KM-IMB
External Grant-Devision of Research-19March2024-KM-IMBTassanee Lerksuthirat
 
Preparation note on longevity for discussion
Preparation note on longevity for discussionPreparation note on longevity for discussion
Preparation note on longevity for discussionTassanee Lerksuthirat
 
Meeting report - policy distribution from MHESI
Meeting report - policy distribution from MHESIMeeting report - policy distribution from MHESI
Meeting report - policy distribution from MHESITassanee Lerksuthirat
 
คู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัย
คู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัยคู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัย
คู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัยTassanee Lerksuthirat
 
Sentiment Analysis for Public Opinions in Healthcare_Redacted.pdf
Sentiment Analysis for Public Opinions in Healthcare_Redacted.pdfSentiment Analysis for Public Opinions in Healthcare_Redacted.pdf
Sentiment Analysis for Public Opinions in Healthcare_Redacted.pdfTassanee Lerksuthirat
 
Fluorescence microscope (Ci-L) - SOP
Fluorescence microscope (Ci-L) - SOPFluorescence microscope (Ci-L) - SOP
Fluorescence microscope (Ci-L) - SOPTassanee Lerksuthirat
 
Fluorescence microscope (Ti Series) - SOP
Fluorescence microscope (Ti Series) - SOPFluorescence microscope (Ti Series) - SOP
Fluorescence microscope (Ti Series) - SOPTassanee Lerksuthirat
 

More from Tassanee Lerksuthirat (20)

External Grant-Devision of Research-19March2024-KM-IMB
External Grant-Devision of Research-19March2024-KM-IMBExternal Grant-Devision of Research-19March2024-KM-IMB
External Grant-Devision of Research-19March2024-KM-IMB
 
Preparation note on longevity for discussion
Preparation note on longevity for discussionPreparation note on longevity for discussion
Preparation note on longevity for discussion
 
Ministerial Regulation
Ministerial RegulationMinisterial Regulation
Ministerial Regulation
 
Note: The aging brain
Note: The aging brainNote: The aging brain
Note: The aging brain
 
Meeting report - policy distribution from MHESI
Meeting report - policy distribution from MHESIMeeting report - policy distribution from MHESI
Meeting report - policy distribution from MHESI
 
Shorten link.pdf
Shorten link.pdfShorten link.pdf
Shorten link.pdf
 
Experimental design for biologists
Experimental design for biologistsExperimental design for biologists
Experimental design for biologists
 
Note in RIAC2023 (day 3)
Note in RIAC2023 (day 3)Note in RIAC2023 (day 3)
Note in RIAC2023 (day 3)
 
Note in RIAC2023 (day 2)
Note in RIAC2023 (day 2)Note in RIAC2023 (day 2)
Note in RIAC2023 (day 2)
 
Note in RIAC2023 (day 1)
Note in RIAC2023 (day 1)Note in RIAC2023 (day 1)
Note in RIAC2023 (day 1)
 
คู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัย
คู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัยคู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัย
คู่มือการปฏิบัติตนเมื่อเกิดเหตุอัคคีภัย
 
Sentiment Analysis for Public Opinions in Healthcare_Redacted.pdf
Sentiment Analysis for Public Opinions in Healthcare_Redacted.pdfSentiment Analysis for Public Opinions in Healthcare_Redacted.pdf
Sentiment Analysis for Public Opinions in Healthcare_Redacted.pdf
 
Upright microscope location
Upright microscope locationUpright microscope location
Upright microscope location
 
Upright Lens
Upright LensUpright Lens
Upright Lens
 
Computer specification
Computer specificationComputer specification
Computer specification
 
MU saving seminar note
MU saving seminar noteMU saving seminar note
MU saving seminar note
 
Nikon Ti-U Manual (Eng)
Nikon Ti-U Manual (Eng)Nikon Ti-U Manual (Eng)
Nikon Ti-U Manual (Eng)
 
Ci-S-Ci-L (Eng-Manual).pdf
Ci-S-Ci-L (Eng-Manual).pdfCi-S-Ci-L (Eng-Manual).pdf
Ci-S-Ci-L (Eng-Manual).pdf
 
Fluorescence microscope (Ci-L) - SOP
Fluorescence microscope (Ci-L) - SOPFluorescence microscope (Ci-L) - SOP
Fluorescence microscope (Ci-L) - SOP
 
Fluorescence microscope (Ti Series) - SOP
Fluorescence microscope (Ti Series) - SOPFluorescence microscope (Ti Series) - SOP
Fluorescence microscope (Ti Series) - SOP
 

Recently uploaded

Fostering Friendships - Enhancing Social Bonds in the Classroom
Fostering Friendships - Enhancing Social Bonds  in the ClassroomFostering Friendships - Enhancing Social Bonds  in the Classroom
Fostering Friendships - Enhancing Social Bonds in the ClassroomPooky Knightsmith
 
Towards a code of practice for AI in AT.pptx
Towards a code of practice for AI in AT.pptxTowards a code of practice for AI in AT.pptx
Towards a code of practice for AI in AT.pptxJisc
 
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...christianmathematics
 
SOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning PresentationSOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning Presentationcamerronhm
 
Unit-V; Pricing (Pharma Marketing Management).pptx
Unit-V; Pricing (Pharma Marketing Management).pptxUnit-V; Pricing (Pharma Marketing Management).pptx
Unit-V; Pricing (Pharma Marketing Management).pptxVishalSingh1417
 
Micro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfMicro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfPoh-Sun Goh
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024Elizabeth Walsh
 
Spellings Wk 3 English CAPS CARES Please Practise
Spellings Wk 3 English CAPS CARES Please PractiseSpellings Wk 3 English CAPS CARES Please Practise
Spellings Wk 3 English CAPS CARES Please PractiseAnaAcapella
 
Introduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The BasicsIntroduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The BasicsTechSoup
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxAreebaZafar22
 
Application orientated numerical on hev.ppt
Application orientated numerical on hev.pptApplication orientated numerical on hev.ppt
Application orientated numerical on hev.pptRamjanShidvankar
 
Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsKarakKing
 
ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701bronxfugly43
 
Accessible Digital Futures project (20/03/2024)
Accessible Digital Futures project (20/03/2024)Accessible Digital Futures project (20/03/2024)
Accessible Digital Futures project (20/03/2024)Jisc
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdfQucHHunhnh
 
How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17Celine George
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxDenish Jangid
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...ZurliaSoop
 

Recently uploaded (20)

Fostering Friendships - Enhancing Social Bonds in the Classroom
Fostering Friendships - Enhancing Social Bonds  in the ClassroomFostering Friendships - Enhancing Social Bonds  in the Classroom
Fostering Friendships - Enhancing Social Bonds in the Classroom
 
Towards a code of practice for AI in AT.pptx
Towards a code of practice for AI in AT.pptxTowards a code of practice for AI in AT.pptx
Towards a code of practice for AI in AT.pptx
 
Spatium Project Simulation student brief
Spatium Project Simulation student briefSpatium Project Simulation student brief
Spatium Project Simulation student brief
 
Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024
 
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
 
SOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning PresentationSOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning Presentation
 
Unit-V; Pricing (Pharma Marketing Management).pptx
Unit-V; Pricing (Pharma Marketing Management).pptxUnit-V; Pricing (Pharma Marketing Management).pptx
Unit-V; Pricing (Pharma Marketing Management).pptx
 
Micro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfMicro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdf
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024
 
Spellings Wk 3 English CAPS CARES Please Practise
Spellings Wk 3 English CAPS CARES Please PractiseSpellings Wk 3 English CAPS CARES Please Practise
Spellings Wk 3 English CAPS CARES Please Practise
 
Introduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The BasicsIntroduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The Basics
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
Application orientated numerical on hev.ppt
Application orientated numerical on hev.pptApplication orientated numerical on hev.ppt
Application orientated numerical on hev.ppt
 
Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functions
 
ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701
 
Accessible Digital Futures project (20/03/2024)
Accessible Digital Futures project (20/03/2024)Accessible Digital Futures project (20/03/2024)
Accessible Digital Futures project (20/03/2024)
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
 
How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
 

EN_quick-guide_ZEN-blue-edition_first-steps.pdf

  • 1. Quick Guide ZEISS ZEN (blue edition)
  • 2. ZEISS ZEN (blue edition) Original Manual Carl Zeiss Microscopy GmbH Carl-Zeiss-Promenade 10 07745 Jena Germany microscopy@zeiss.com www.zeiss.com/microscopy Carl Zeiss Microscopy GmbH ZEISS Group Kistlerhofstr. 75 81379 München Document Name: ZEISS ZEN (blue edition) Quick Guide Revision: 2 Language: en-US Effective from: 04/2021 © 2021 Without the prior written consent of ZEISS, this document or any part of it must neither be translated nor reproduced or transmitted in any form or by any means - including electronic or mechanic methods, by photocopying, recording or by any in- formation or filing system. The right to make backup-copies for archiving purposes shall remain unaffected thereby. Any viola- tions may be prosecuted as copyright infringements. The use of general descriptive names, registered names, trademarks, etc. in this document does not imply that such names are exempt from the relevant intellectual property laws and regulations and therefore free for general use. This shall also apply if this is not specifically referred to. Software programs shall entirely remain the property of ZEISS. No program or subsequent up- grade thereof may be disclosed to any third party, copied or reproduced in any other form without the prior written consent of ZEISS, even if these copies or reproductions are destined for internal use at the customer's only, the only exception being one single back-up copy for archiving purposes. ZEISS reserves the right to make modifications to this document without notice.
  • 3. ​ Inhalt​ ZEISS Inhalt 1 Welcome ....................................................................................... 4 2 Starting Software.......................................................................... 5 3 User Interface................................................................................ 6 3.1 Title bar...................................................................................................... 6 3.2 Workspace Configuration........................................................................... 7 3.3 Menu bar ................................................................................................... 7 3.4 Tool bar ..................................................................................................... 7 3.5 Left Tool Area ............................................................................................ 8 3.6 Center Screen Area..................................................................................... 9 3.7 Right Tool Area .......................................................................................... 10 3.8 Document bar ............................................................................................ 10 3.9 Status bar................................................................................................... 10 3.9.1 System Messages........................................................................ 12 4 Adjusting Workspace Appearance................................................. 13 4.1 Setting User Language ............................................................................... 13 4.2 Selecting Screen Design.............................................................................. 13 4.3 Adjusting Workspace Zoom........................................................................ 13 4.4 Showing/Hiding Workspace Areas.............................................................. 13 4.5 Undocking/Docking Tool Windows............................................................. 14 4.6 Activating Show All Mode.......................................................................... 14 5 Step by step to the first image ...................................................... 16 5.1 Configuring Microscope Components......................................................... 16 5.2 Acquiring Camera Image............................................................................ 17 5.3 Adding Annotations ................................................................................... 19 5.4 Adjusting Live Image Settings..................................................................... 19 5.5 Creating Manual Scaling............................................................................. 20 6 Closing the Software ..................................................................... 21 Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 3
  • 4. 1 Welcome​ ZEISS 1 Welcome ZEN (blue edition) is a modular image acquisition, processing and analysis software for digital mi- croscopy. The abbreviation ZEN stands for ZEISS Efficient Navigation and points out that the soft- ware can be used to control microscopes and imaging systems by ZEISS. In addition to basic functionality for image acquisition, elementary image processing and annota- tions and image analysis a lot of optional modules for specific microscopy tasks are available. With ZEN lite the basic version of the software is available for free. Starting from a basic function- ality for image acquisition, simple image processing, image analysis and documentation a lot of optional modules are available for ZEN lite as well. More detailed information is available in the product brochure. Disclaimer This product is not intended for use in medical or diagnostic procedures. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 4
  • 5. 2 Starting Software​ ZEISS 2 Starting Software Prerequisite ü You have switched on the hardware components to be ready for operation. ü You have installed ZEN (blue edition) on your computer. 1. Double-click on the program icon on your desktop. 2. Alternatively click Start > Carl Zeiss Microscopy > ZEN (blue edition). à The software starts and displays a loading screen. After a while you see the login screen. 3. Click on the application you want to work with. The available applications depend on your licenses and system (e.g. if you work with an LSM, only ZEN system and Image Process- ing are available). à The software starts. During the program start the hardware settings will be initialized. Info Using pre-recorded Images For using pre-recorded images when starting the software, in the menu Tools > Options > Startup, the Reload Last Used Documents checkbox must be activated. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 5
  • 6. 3 User Interface | 3.1 Title bar ZEISS 3 User Interface The software user interface is divided into three main areas. 1 2 3 Fig. 1: User interface 1 Left Tool Area With the tabs you can access all the main tools for microscope control (Locate Tab), ac- quisition (Acquisition Tab), image processing (Processing Tab), image analysis (Analysis Tab), and applications (Applications Tab). 2 Center Screen Area This area is used to display your images with several image views available. For more in- formation, see Center Screen Area [} 9]. 3 Right Tool Area Here you find the Images and Documents Tool, the Objective Selection and the Stage and Focus controls. Additionally system specific tools can be available here (e.g. Definite Focus and ZEN Connect controls). 3.1 Title bar Parameter Description Help icon Activates the "drag & drop“ help function. A question mark ap- pears beside the mouse pointer. Move the mouse pointer to a place in the software where you need help. Left-click on the de- sired location. The online help opens. Minimize Minimizes the program window. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 6
  • 7. 3 User Interface | 3.2 Workspace Configuration ZEISS Parameter Description Maximize Over 2 Screens Maximizes the program window across 2 screens if available. This option is only possible if you are working with 2 screens with the same resolution. Maximize Maximizes the program window to the main screen. Restore Down Reduces the program window to any selected size. Close Closes the program window. 3.2 Workspace Configuration Fig. 2: Workspace Configuration Here you find settings to adjust your workspace. Select Light/Dark Design of the user interface or enlarge the screen with Workspace Zoom slider. You can also save and reload all personal settings in a workspace configuration. With the Dock all tool windows button in the top right corner you can easily dock all undocked tools by one click. 3.3 Menu bar Fig. 3: Menu bar The menu bar contains all the menus you need for managing, editing, and viewing your projects. 3.4 Tool bar Fig. 4: Tool Bar Here you gain quick access to important functions, e.g. saving or opening files. Further right you find more workspace settings, e.g. Design and Workspace selection. Read how to customize the Tool bar in chapter Customize toolbar. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 7
  • 8. 3 User Interface | 3.5 Left Tool Area ZEISS 3.5 Left Tool Area This area contains the main tabs for microscope and camera settings (Locate tab), image acquisi- tion (Acquisition tab), image processing (Processing tab), and image analysis (Analysis tab). The main tabs are organized in an order which follows the typical workflow of experiments in bio- science or material science. Fig. 5: Left Tool Area Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 8
  • 9. 3 User Interface | 3.6 Center Screen Area ZEISS 3.6 Center Screen Area The Center Screen Area is structured in 4 areas. 1 2 3 4 Fig. 6: Center Screen Area 1 Document bar Here you can switch between all your opened documents. For more information, see Document bar [} 10]. 2 Image Views Area where you can switch between different image views by selecting the correspond- ing tab in the list. For more information, see also Image views. 3 View Options Area for general and specific view options. For more information, see also General View Options. 4 Image Area Area where images, reports, and tables are displayed. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 9
  • 10. 3 User Interface | 3.7 Right Tool Area ZEISS 3.7 Right Tool Area This area contains mainly the tools for image and file handling (e.g. Image Gallery) and hardware control (e.g. Stage / Focus tool). Depending on your system configuration, other tools can be available. The tools are described in the corresponding chapters of the online help. 3.8 Document bar Here you see tabs of all open documents. Click on a tab to view the image/document. On the right end of document bar you find buttons to switch view mode from Exposé to Splitter mode and further view options (View menu). Info A asterisk (*) next to an image/document title indicates that unsaved changes have been made to this document. Save your pictures/documents from time to time in order to avoid data loss. Parameter Description Exposé Mode Opens the exposé view mode. For more information, see Exposé mode. Splitter Mode Opens the splitter view mode. For more information, see Splitter mode. Options Displays the options of the view menu. For more information about the individual options, see View Menu. 3.9 Status bar The status bar shows important information on the system status: Parameter Description Scaling Displays which lateral scaling is currently being used. If you click on the arrow, the Scaling dialog will be opened. There you have access to advanced scaling settings and the scaling wizard. System Informa- tion Always shows the latest, currently active process that the system is performing. Progress bar Displays the progress of the currently active process. Each new process added supersedes older still active processes. If you click on the arrow button, a window opens with a list of all processes in chronological order. You can stop a process that is running using the Stop button. Performance indi- cators In this group you will see an overview of the performance of individ- ual computer components: § Free RAM indicates how much physical memory is still available. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 10
  • 11. 3 User Interface | 3.9 Status bar ZEISS Parameter Description § Free HD indicates how much space is still available on the hard drive onto which the next image is to be acquired (see Tools > Op- tions > Saving). § CPU indicates the usage of the Central Processing Unit. § The small status bar provides an overall assessment of the system usage. § GPU indicates the usage of the Graphics Processing Unit by ZEN and ZEN related services. It is also visualized by a small status bar on its right. Note: This GPU indicator is only visible if you your computer has Microsoft Windows 10 version 1709 or higher. Info: Double-clicking in the Performance Indicators area opens the Windows Task Manager. Frame Rate Indicates the current frame rate in frames per second (fps) used by the active camera for producing new images. Please note in most cases that at speeds greater than 100 frames per second, this value cannot always be accurately determined. Pixel Value Displays the gray value to the image at the current position of the mouse pointer. In the case of multichannel images the gray value/ channel is displayed for up to 4 channels. Position Displays the X/Y position (in pixel coordinates) of the mouse pointer in the image. Information (i) If you click on the icon, a window opens with a System Messages [} 12]. Storage Folder Displays the location where new images are automatically saved. This path can be changed in the menu Tools > Options > Saving. Status: Airyscan Detector Align- ment If you click on the arrow the Alignment Tool window opens. See Airyscan Detector Adjustment. User Shows the Windows user name of the logged in user. Time Shows the current Windows system time. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 11
  • 12. 3 User Interface | 3.9 Status bar ZEISS 3.9.1 System Messages If you right-click on a system message the Copy button will appear. Left-click on Copy button to copy the message to clipboard. Then paste it into a text file or an E-Mail. The idea behind is that you can easily send error messages to your support team for example. This copy/paste function works for all upcoming system messages or error messages within the application as well. Parameter Description Information System information that arises during normal operation. This system information does not lead to an interruption of the workflow. The in- formation window is not displayed automatically. Warnings Information that requires input from the user, e.g. a prompt to change a manual microscope component. This information leads to the information window being shown briefly. However, it closes again after a few seconds. Errors Error messages indicate a malfunction by the system. In this case the information window opens and remains open. The system requires in- put from the user in order to continue. Info Hundreds of messages can accumulate in the course of a session. A maximum of 300 mes- sages are displayed. To display messages for a certain category, activate or deactivate the cor- responding checkboxes. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 12
  • 13. 4 Adjusting Workspace Appearance | 4.1 Setting User Language ZEISS 4 Adjusting Workspace Appearance 4.1 Setting User Language Info If the Select Automatically checkbox is activated, the software uses the language which is set in the system settings of your computer. This is the default setting. Prerequisite ü You have started the application. 1. Go to Tools > Options dialog. à In the group Software the entry General is selected. 2. Deactivate the Select Automatically checkbox to select the language manually. 3. Select the user language from the Fixed Language drop-down list. à A message appears to restart the application. à Note that the availability of additional languages can differ between software versions. 4. Click OK. à The Options dialog closes. 5. Exit and restart software. 4.2 Selecting Screen Design In the upper right corner of the program window under Design you can select a Light or Dark screen layout . Optionally, you can change the design with the shortcut Ctrl+D. 4.3 Adjusting Workspace Zoom 1. To zoom in or out of the workspace move the slider left or right. 2. To reset the workspace zoom to default click Reset. 4.4 Showing/Hiding Workspace Areas 1. Click Show/Hide to show or hide screen areas. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 13
  • 14. 4 Adjusting Workspace Appearance | 4.5 Undocking/Docking Tool Windows ZEISS 4.5 Undocking/Docking Tool Windows This function allows you to undock/dock a tool window. An undocked tool window can be posi- tioned anywhere on the screen. 1. Click Undock to undock a tool window. Once undocked, the tool window can be moved around by clicking and dragging it on the blue bar. 2. Click Dock to dock a tool window back to its place in the left tool area. Info With the dock all tools function in the Workspace Configuration you can globally attach all undocked tool windows back to the Left Tool Area. 4.6 Activating Show All Mode 1. With the Show All mode deactivated (default setting), only the basic functions of tool win- dows or view options are shown. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 14
  • 15. 4 Adjusting Workspace Appearance | 4.6 Activating Show All Mode ZEISS 2. To show the advanced settings or expert functions of tool windows or view options, click Show All. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 15
  • 16. 5 Step by step to the first image | 5.1 Configuring Microscope Components ZEISS 5 Step by step to the first image 5.1 Configuring Microscope Components This chapter refers to the manual configuration of the microscope components in ZEN lite. All mi- croscope components definitions will be stored in the meta data of the acquired image. Prerequisite ü You have selected the Camera tab. 1. Click Microscope Components. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 16
  • 17. 5 Step by step to the first image | 5.2 Acquiring Camera Image ZEISS à The tool will open. Consider that the button Show all is activated. 2. For Objective select that objective you will use for your acquisitions. 3. Select all other microscope components you will use (i.e. Optovar, Reflector, etc.). You have successfully configured your microscope components. Info If you have activated the Select automatically button in the status bar under Scaling (stan- dard settings), the scaling will be calculated on the basis of your definitions. If you want to perform a manual scaling, read the chapter Creating Manual Scaling [} 20]. 5.2 Acquiring Camera Image This topic guides you through acquiring your first camera image with the software. Prerequisite ü You have connected and configured a microscope camera (i.e. Axiocam 305 color/mono) to your system. ü You have started the software. ü You have configured the microscope components (e.g. objective, camera adapter) und you are using the automatic or manual scaling. ü You are on the Camera (ZEN lite only) or Locate tab. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 17
  • 18. 5 Step by step to the first image | 5.2 Acquiring Camera Image ZEISS ü You see your microscope camera available in the Active Camera section. If not, select the camera from the list. 1. Position your sample on the microscope and adjust the microscope to see a focused image through the eyepieces. 2. Adjust the tube slider of the microscope to divert the image to the camera (e.g. 50% cam- era and 50% eyepieces). 3. Click Live. à The Live Mode will be activated. In the Center Screen Area you will see the camera live image. By default the live image shows a cross hair helping to navigate on the speci- men. In the chapter Adjusting Live Image Settings [} 19] you will learn how to optimize live image display. 4. Click Set Exposure. à The exposure time will be automatically determined and set. 5. Click Snap. You successfully acquired your first image. Save the image in the file system via the File menu | Save as. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 18
  • 19. 5 Step by step to the first image | 5.3 Adding Annotations ZEISS Info If you do not see a focused image, please refocus the specimen on the microscope. You may activate the focus bar as an additional aid. Right-click in the Center Screen Area to open the context menu. Select the entry Focus Bar. The focus bar will be shown. See also 2 Document bar [} 10] 5.3 Adding Annotations Annotations are the generic term for all the graphics (e.g. rectangle, arrow, scale), measurements, texts or other metadata (e.g. recording time) that you can add to your image. Prerequisite ü You have acquired or loaded an image. 1. In the Center Screen Area select Graphics. 2. Click Scale Bar. à The scale bar will appear directly in the image. à To edit an annotation (e.g. color, line width) you can right-click on the annotation in the image and select Format Graphical Elements from the context menu. 3. Click Draw Arrow. à You can now draw an arrow into the image. 5.4 Adjusting Live Image Settings Prerequisite ü You have started the Live mode via the Live button and see the camera’s live image in the Center Screen Area. ü Under the image area you see the general view options on Dimensions tab, Graphics tab and Display tab. 1. In the Dimensions tab activate the Range Indicator checkbox. This will mark overexposed (too bright) areas in the live image in red and underexposed (too dark) areas in blue. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 19
  • 20. 5 Step by step to the first image | 5.5 Creating Manual Scaling ZEISS 2. On the Display tab click 0.45. The display curve will be adapted to a gamma value of 0.45. This will set the optimum color presentation. If you do not see this button, activate the Show all mode. 3. Move the controls under the display curve left and right in order to directly adjust the val- ues for Contrast (Black) 1 , Gamma 2 , and Brightness (White) 3 in the live image. 1 2 3 Info With the settings above the display of the live image will be adapted. These settings will also be transferred to your acquired image. This will not change the camera settings. 5.5 Creating Manual Scaling Prerequisite ü You have an object micrometer oriented horizontally on the microscope stage. ü You have selected all definitions for your microscope correctly in the Microscope Compo- nents tool (ZEN lite only). In our example we use an objective with a 10x magnification. 1. Acquire an image (see Acquiring Camera Image [} 17]) of the scale in your object microme- ter using the objective to be scaled manually. 2. In the bottom status bar click Scaling. In the Scaling dialog deactivate Select Automati- cally. 3. In the Create new scaling section, click Interactive Calibration.... à The calibration wizard will appear in the image area. 4. Click Single Reference Line and activate Automatic Line Detection. 5. Draw in the reference line along the scale. 6. Enter the true distance between both scale lines in the calibration wizard. In our example this is 500 micrometer. 7. Enter a name for the scaling (i.e. Obj 10x) and click Save Scaling. You performed a manual scaling for your objective. Repeat this sequence for all objectives you will need a manual scaling for. Always ensure that you did select the correct objective in the tool Mi- croscope Components and for this performed and selected the matching scaling in the status bar. Info 4 The function Automatic Line Detection calculates the theoretical maximum of the refer- ence line‘s both end points to the closest scale lines in the image. Thus the distance will be calculated with sub-pixel accuracy. 4 If you have defined a manual scaling for an objective and activate the checkbox Select Automatically, the software will use the measured scaling instead of the theoretic one. You will recognize this via the label "Measured" instead of "Theoretic" beside the pixel size. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 20
  • 21. 6 Closing the Software​ ZEISS 6 Closing the Software 1. Click File > Exit. Alternatively you can use the short cut Alt+F4 or click Close in the pro- gram bar. Info If you have not saved your files, the Save Documents dialog will open before the software closes. Select the files you want to save or unselect the files you do not want to save. Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 21
  • 22. Carl Zeiss Microscopy GmbH Carl-Zeiss-Promenade 10 07745 Jena Germany phone: +49 3641 64 3161 fax: +49 3641 64 3439 info.microscopy@zeiss.com www.zeiss.com/microscopy Quick Guide ZEISS ZEN (blue edition) | en-US | Rev.2 Modifications reserved.