Force Sensor DAQ
Connecting a Force Sensor to a Data
Acquisition System
Introduction
This digital era is marked by a lot of technologies – they have become so
familiar — so that they are very hard to identify as a single device. More
systems have become so complex and are built from the integration of sev-
eral subsystems.
Instrumentation deals with combining subsystems in order to accurately
measure, control, or observe a system. An example of such a system is the
type that connects a force sensor and a data acquisition (DAQ) device.
This type of system – whose objective might be to control or measure cer-
tain processes — is developed by connecting several units together.
This article discusses the various subsystems of a sensor-DAQ setup and
uses some of Tacuna System’s devices to explain some concepts better.
The Elements Of The Force Sensor – Data
Acquisition System Setup
To fully understand how the various subsystems are integrated — in con-
necting a force sensor and a DAQ system – it is important to have a gen-
eral overview – a block diagram — of the system and the function of each
block.
2. The block diagram in figure 1 below shows the force transduction unit, the
signal conditioning unit, and the data acquisition unit.
The Operation And Functions Of Each Unit
A. The Force sensor / Transduction Unit:
A sensor detects a physical phenomenon — such as force in the case of
this article – and transforms the detected quantity into an equivalent output.
The output might be pneumatic, mechanical, or electrical –– in the process
called electrical transduction.
These devices, the force transducers, are built based on some physical
principles that allow them to produce electrical signals when a physical
force is exerted on them. Hence the various physical principles form the ba-
sis on which these devices are classified.
Basically, the following are the common types of force sensors: the hydrau-
lic types, the pneumatic types, the capacitive types, and strain gauge types.
There are still many other force sensors other the ones listed above.
The hydraulic force sensor works on the principle of force-balance, that al-
lows it to use a piston and a fluid contained in a sealed cylinder chamber to
perform the measurement. The piston-fluid interface transmits the force ex-
erted on the loading platform to a pressure indicator or a pressure trans-
ducer.
3. The pneumatic type also works on the same principle of force-balance but
it instead of a fluid, it works with compressed air or gas.
The capacitive force sensor uses the relationship between the distance of
separation of two charged plates and the capacitance. A plate is made sta-
tionary while the other is movable. The force exerted on the moveable plate
decreases or increases its distance from the stationary plate, hence pro-
ducing an output capacitance that is proportional to the applied force.
The strain force sensor type also called a strain gauge load cell is the most
commonly used among the types listed earlier. This load cell uses an elas-
tic resistive material — called the strain gauge – attached to the structural
member of the device, to transform the force into an electrical voltage out-
put. When a force is applied to the load cell’s application point, it is trans-
formed into a strain by the structural members.
This strain is then transmitted mechanically to the strain gauge which de-
forms elastically in order to produce a change in its resistance. This change
in resistance is then converted into an electrical voltage by including the
strain gauge in a Wheatstone bridge circuit. Therefore, the strain gauge
load cell has about four wires: two power supply/excitation wires and two
output signal wires.
Figure 2. An Anyload Strain Gauge
Load Cell
B. The Signal Conditioning Unit:
This is the intermediary unit that exists between the transduction unit and
the DAQ unit. It performs the work of transforming the output from the
transducer unit into a form that is compatible with the data acquisition unit.
4. This signal conditioning process basically involves Isolation, signal filtering,
and signal amplification.
i. Isolation:
Consider a case where the force sensor is to be powered through a regu-
lated supply on the signal conditioner circuit, the use of an electrical isolator
is necessary. It will isolate the force sensor from a direct connection to the
power supply. The advantage of this helps to cater for fault currents. Isola-
tion can be done by a magnetic isolator – e.g. a transformer – or an optical
isolator — e.g. an opto-coupler.
Figure 3. A Schematic for an Opto-
coupler
ii. The Signal Amplifier:
The signal from the load cell, which has been filtered is routed to the ampli-
fier. It should be noted that this input signal — from the load cell —is very
small, in the order of millivolts (mV). This voltage range cannot be passed
directly to the DAQ unit, because the DAQ will not be able to detect it,
hence no useful work can be done with it. The need for amplifier then
arises. The amplifier serves to increase the dynamic range of the sensor
output to a level equal to or near the dynamic range of the DAQ.
There are about two methods that can be used to transform this low volt-
age signal into a reasonable level that can be used by the DAQ unit. First,
the output terminals from the sensor can be made to be part of a voltage di-
vider circuit; the voltage divider output is then amplified by a differential am-
plifier.
Second, the sensing device can be incorporated into an arm of a Wheat-
stone bridge – as in the case of a strain gauge load cell – then have its out-
put terminals connected to an amplifier. The widely used amplifier in the in-
dustry is the Instrumentation amplifier. Its advantages over the normal dif-
5. ferential amplifier include its high and stable gain value, very high input im-
pedance, very low output impedance, and an extremely high common-
mode rejection ratio.
Figure 4. An Instrumentation Amplifier Circuit Configuration
iii. The Signal Filtering:
This is the process of removing unwanted signals – noise – from a signal.
This can be implemented by using specially designed circuits – active and
passive filters – or by simply placing a bypass capacitor between the posi-
tive terminal of the signal path and the ground terminal of the signal path.
The capacitor will serve as a low pass filter as it will conduct high-frequency
signals – AC noise to ground. Filtering is always needed directly before the
amplifier and output of the amplifier – the end of the signal conditioning
stage.
Figure 5. A Bypass Capacitor
In summary, the power supply to the load sensor is isolated, then the out-
put voltage is passed through a filter placed directly in front of the amplifier
stage. The instrumentation amplifier presents a low input impedance signal
6. source to the DAQ; so that changes in the input of the DAQ do not affect
the output from the amplifier.
C. The Data Acquisition (DAQ) Unit:
This unit receives the conditioned signal — the conditioned signal – from
the force sensor. The major roles of the DAQ subsystem are to perform
digital signal processing on the received signal, meaning this subsystem is
a digital system. It is basically made up of the following digital signal pro-
cessing units: The anti-aliasing filter, the sample-hold (S-H) circuit, the
quantizer-encoder circuit, and the digital signal processor – analogous to a
microprocessor.
i. The Anti-Aliasing Filter:
It is the filter circuit that is located directly at the output terminal of the am-
plifier. This analog filter circuit serves to band limit the input entering the
DAQ unit from the amplifier circuit. The band limit is necessary so as to en-
sure that the input signal frequency components higher than half of the
DAQ’s specified sampling frequency is removed.
Without the anti-aliasing filter, there would be difficulties in processing or
recovering a sampled signal. The sampled signal will contain various over-
lapping and indistinguishable frequency components. This overlapping ef-
fect is called Aliasing. The anti-aliasing filter is built from the unit specifica-
tions and mathematical tools – frequency domain tools.
ii. The Sample and Hold Circuit:
This component performs sampling: the acquisition of a continuous signal
at discrete time intervals resulting in a sequence of samples. Sampling is
done based on the Nyquist Theorem which states: an input analog signal
can be accurately reconstructed from its sampled version if it is sampled at
a rate that is at least twice its highest frequency component.
This shows why an anti-aliasing filter is needed at first since the filter limits
the analog signal from the amplifier to a certain bandwidth – lower or equal
to half of the sampling rate.
The Sample and Hold circuit (S-H) is then designed to sample the analog
signal the sampling rate. The S-H circuit is made up of a solid-state high-
frequency switch, a holding capacitor, and a buffer amplifier– a voltage fol-
lower.
7. In practice, the S-H circuit is very key to the sampling process because the
input analog signal is time-varying. To truly sample this signal, its instanta-
neous value at each specific time needs to be determined. The circuit holds
the instantaneous value steady till the next time interval. The processing of
the held signal value has to be performed within that holding time period in
order to achieve an accurate result.
The figure below shows a simple S-H circuit. This unit, therefore, converts
the analog signal into a discrete-time signal – continuous in amplitude but
discrete in the time domain.
Figure 4. A Practical S-H circuit
iii. The Quantizer and The Encoder:
The quantizer unit serves to perform what can be described as sampling in
the amplitude domain. Quantization creates a range of equally spaced lev-
els, where B is the number of bits used in the analog-to-digital converter
(ADC). This means that each level exists between only two possible limits,
hence the signal is said to have been quantized.
The encoder then assigns a certain binary code to each of these levels.
The encoder can use either of these two encoding schemes: the two’s
complement coding scheme or the offset binary coding scheme. Therefore,
the output of the encoder is a digital signal.
Please note that the S-H circuit, the quantizer, and the encoder forms the
ADC. This is so because the input to the S-H circuit is analog and the out-
put from the encoder is digital.
iv. The Digital Signal Processor (DSP):
This performs certain processing operations on the digital signal: frequency
and time domain analysis, filtering, convolution, and correlation.
8. The DSP is a unit that has its own subsystems. Also, it runs on a dedicated
hardware architecture that is quite similar to that of a general microproces-
sor. The special hardware unit of the DSP includes multipliers, accumulator
unit, shifters, address generators, data memory, and a program memory.
The digitized signal is stored on the DSP memory to be retrieved later for
processes such as display or process control.
The architecture of a DSP is shown below.
Figure 5. The Architecture of a DSP
Finally, a telemetry system can be integrated with the DAQ subsystem for
the purpose of transmitting the digitized force sensor output accurately over
a long distance to a remote location.
The detailed block Diagram of the units and subsystems that connects the
force sensor and the DAQ is shown in the figure 6 below.
Figure 6. The Detailed Block Diagram
of the Setup
A Look At A Some Hardware Products
The data acquisition hardware shown in the figure below is a portable de-
vice that can aggregate input from several sensors. It has multiple input
channels through which several sensor units can connect to it. This device
also has the capacity to transmit the aggregated data to a central remote
location through a wireless network.
9. Figure 7. Nyquist 3 DAQ Hardware
The features and specifications of this device are shown in the figure be-
low. It can be seen that it offers both wired and wireless telemetry systems,
it has a data logging system, its sampling rate is 1000Hz, and it has 16 in-
put channels.
Fig-
ure 8. The features and Specifications of a Nyquist 3
Also, note that the analog input channels have a dynamic range of 0-5V
with a sink/source current of 30mA. This means the sensor connecting to
any of the channels on this must have had its output amplified to that dy-
namic range.
10. Tacuna systems also offer a wide range of amplifiers and conditioners that
can then be used to interface a force sensor — such as a strain gauge load
cell – to this DAQ hardware. A sample amplifier and its datasheet specifica-
tions are shown in the figures below.
Figure 9. An AnyLoad A1A-22 Load
Cell Amplifier
Figure 10. The Amplifier’s
datasheet
The datasheet shows the amplifier gain, the load cell type it supports, the
input range –- from a sensor—it supports, the output voltage and current.
Note that the output voltage and current signal value all fall within the dy-
namic range of the DAQ device. Hence you have your complete package
all ready to be coupled together to get your system up and running in a
short period of time.