SlideShare a Scribd company logo
1 of 22
Dr. Santanu Chakravorty
CHEMISTRY-DSE: ANALYTICAL METHODS IN
CHEMISTRY
Dr. Santanu Chakravorty
Assistant Professor
Mathabhanga College
1
Dr. Santanu Chakravorty
Syllabus
Chromatography: Classification, principle and efficiency of the
technique. Mechanism of separation: adsorption, partition & ion
exchange. Development of chromatograms: frontal, elution and
displacement methods. Qualitative and quantitative aspects of
chromatographic methods of analysis: IC, GLC, GPC, TLC and HPLC
2
Dr. Santanu Chakravorty
Principles of Chromatography
Chromatography now refers to any of a diverse group of techniques that effect a
separation through a distribution of sample between two immiscible phases. The
requirement to distinguish chromatography from other separation technique is
that one phase be stationary while the second phase be mobile and percolating
through the first phase resulting in selective retention of the components of a
mixture by the stationary phase. The stationary phase which may be solid or liquid
or may consists of a mixture of a solid and liquid , is finely divided and is fixed in
place. The mobile phase, which may be liquid or gaseous, fills the interstices of the
stationary phase and is able to flow through the stationary phase. The physical
states of the mobile and stationary phases give rise to four basic type of
chromatography
i. liquid-solid chromatography, (LSC) ii. Liquid-liquid chromatography, (LLC) iii. Gas-
liquid chromatography, (GLC) iv. Gas-solid chromatography (GSC)
Solid stationary phase also gives rise to low exchange chromatography. Separation
of the components, or solutes of a sample results from differences in their rate of
adsorption.
3
Dr. Santanu Chakravorty
Classification
• The purpose of applying chromatography which is used as a method of quantitative analysis
apart from its separation, is to achieve a satisfactory separation within a suitable time
interval. Various chromatography methods have been developed to that end. Some of them
include column chromatography, thin-layer chromatography (TLC), paper chromatography,
gas chromatography, ion exchange chromatography, gel permeation chromatography, high-
pressure liquid chromatography, and affinity chromatography.
Types of chromatography
• Column chromatography
• Ion-exchange chromatography
• Gel-permeation (molecular sieve) chromatography
• Affinity chromatography
• Paper chromatography
• Thin-layer chromatography
• Gas chromatography
• Dye-ligand chromatography
• Hydrophobic interaction chromatography
• Pseudoaffinity chromatography
• High-pressure liquid chromatography (HPLC)
4
Dr. Santanu Chakravorty
Efficiency of Chromatography techniques
Chromatographic methods will separate ionic species, inorganic or organic, and molecular
species ranging in size from the lightest and smallest, helium and hydrogen, to particulate
matter such as single cells . No single configuration will accomplish this, however. Little
preknowledge of the constituent of a mixture is required. At its best, chromatography will
separate several hundreds of components of unknown identity and unknown concentrations,
leaving the components unchanged. Amounts in the parts per billion range can be detected
with some detectors. The solute can range from polar to nonpolar—i.e., water-soluble to
hydrocarbon-soluble.
• Substances of low critical temperature or low molecular weight, such as the gases at
laboratory conditions showing dispersive or London intermolecular forces only, are separated
with molecular sieves or gas-solid techniques. Gas-liquid chromatography is applicable to
species with high critical temperatures and normal boiling points as high as 400 °C.
Substances that are solids at normal laboratory conditions with molecular weights below
1,000 are best separated with liquid-solid or liquid-liquid systems. Lower members of the
molecular weight scale range are amenable to supercritical fluid separations. Size-
exclusion methods are involved at molecular weights above 1,000. Field-flow fractionation
extends the size range to colloids and microscopic particles.
• Separations are fast, ranging from analysis times of a few minutes to several hours. The
prechromatographic world would have considered a time of several hours to separate
multicomponent mixtures to be miraculously fast. Now several hours is considered excessive,
and there is much emphasis on increasing speed.
5
Dr. Santanu Chakravorty
Adsorption Chromatography
Adsorption chromatography is a type of LC in which chemicals are retained based on their adsorption and
desorption at the surface of the support, which also acts as the stationary phase. This method is also
sometimes referred to as liquid-solid chromatography. Retention in this method is based on the
competition of the analyte with molecules of the mobile phase as both bind to the surface of the support.
The degree of a chemical's retention in adsorption chromatography will depend on (1) the binding
strength of this chemical to the support, (2) the surface area of the support, (3) the amount of mobile
phase displaced from the support by the chemical, and (4) the binding strength of the mobile phase to the
support. Electrostatic interactions, hydrogen bonding, dipole-dipole interactions, and dispersive
interactions (ie, van der Waals forces) all may affect retention in this type of chromatography. The binding
strength of the mobile phase with the support in adsorption chromatography is described by the mobile
phase's elutropic strength. A liquid or solution that has a large elutropic strength for a given support will
act as a strong mobile phase for that material because this mobile phase will tend to bind tightly to the
support and cause the analyte to elute more quickly as it spends more time in the mobile phase. As an
example, a relatively polar solvent such as methanol will have higher elutropic strength for a polar support
such as silica than a nonpolar solvent such as carbon tetrachloride. In the same manner, a liquid or
solution that has a low elutropic strength for a support would represent a weak mobile phase for that
support in adsorption chromatography (eg, carbon tetrachloride on silica). Three types of adsorbents are
generally used in adsorption chromatography: (1) polar acidic supports, (2) polar basic supports, and (3)
nonpolar supports. The most common polar and acidic support used in adsorption chromatography is
silica. The surface silanol groups on this support tend to adsorb polar compounds and work particularly
well for basic substances. Alumina is the main type of polar and basic adsorbent that is used in adsorption
chromatography. Like silica, alumina retains polar compounds, but alumina works especially well for polar
acidic substances. Other types of supports that can be used in adsorption chromatography are nonpolar
adsorbents such as charcoal and polystyrene.
6
Dr. Santanu Chakravorty
Column Chromatography
Column chromatography in chemistry is a chromatography method used to isolate
a single chemical compound from a mixture. Chromatography is able to separate
substances based on differential adsorption of compounds to the adsorbent.
Compounds move through the column at different rates, allowing them to be
separated in fractions. The technique is widely applicable, as many different
adsorbents can be used with a wide range of solvents. The technique can be used
on scales from micrograms up to kilograms. The main advantage of column
chromatography is the relatively low cost and disposability of the stationary phase
used in the process. The latter prevents cross contamination and stationary phase
degradation due to recycling column chromatography can be done using gravity to
move solvent, or using compressed gas to push the solvent through the column.
7
•In column chromatography the stationary phase is packed into a glass or metal column.
•The mixture of analytes is then applied and the mobile phase, commonly referred to as the
eluent, is passed through the column either by use of a pumping system or applied gas
pressure.
•The stationary phase is either coated onto discrete small particles (the matrix) and packed
into the column or applied as a thin film to the inside wall of the column.
•As the eluent flows through the column the analytes separate on the basis of their
distribution coefficients and emerge individually in the eluate as it leaves the column.
Dr. Santanu Chakravorty
Column Chromatography Technique
• Column chromatography is a technique in which the substances to be separated
are introduced onto the top of a column packed with an adsorbent, passed
through the column at different rates that depend on the affinity of each
substance for the adsorbent and for the solvent or solvent mixture, and are usually
collected in solution as they pass from the column at different times.
• It is a solid-liquid technique in which the stationary phase is a solid & the mobile
phase is a liquid or gas.
• It was developed by the American chemist D.T Day in 1900 while M.S. Tswett, the
Polish botanist, 1906 used adsorption columns in his investigations of plant
pigments.
8
Dr. Santanu Chakravorty
Elution, Eluent and Rf value
In a liquid chromatography experiment for example an analyte is generally
adsorbed, or bound to an adsorbent in a liquid chromatography column. The
adsorbent, a solid phase, is a powder which is coated onto a solid support. Based
on an adsorbents composition, it can have varying affinities to hold onto other
molecules-forming a thin film on its surface. Elution then is the process of
removing analytes from the adsorbent by running a solvents, called an eluent pass
the adsorbent/ analyte complex.
The eluent is the carrier portion of the mobile phase. It moves the analytes
through the chromatograph. In liquid chromatography, the eluent is the liquid
solvent, in gas chromatography, it is carrier gas.
9
Dr. Santanu Chakravorty
Elution, Eluent and Rf value
Rf is the retardation factor, which is the ratio of the distance traveled by a
compound in a mobile phase compared with the distance traveled by the front of
the mobile phase itself. It is always greater than or equal to zero, and less than
equal to 1.
• A chromatogram is first to be developed with a suitable solvent (mobile phase),
depending upon the nature of analytes, and the stationary phases. The developed
chromatogram is then dried and the positions (migration values) are measured for
analytes and the solvent front. The Rf (retardation/retention factor) values can be
calculated by using the given procedure using the above experiment.
• A prepared sample solution (A+B) is applied on the chromatogram paper and run
through a mobile phase. Analyte (A) and (B) separate out because of different
affinities with mobile phase (solvent). The relative measurements are taken for the
analytes, the solvent front, and the point where the mixture (A+B) was applied.
10
Dr. Santanu Chakravorty
Rf value calculation
• For the analyte (A)
• Rf = Distance moved by analyte (A) / Distance moved by solvent front
Rf = 2.9 / 4.0 = 0.725
• For the analyte (B)
• Rf = Distance moved by analyte (B) / Distance moved by solvent front
Rf = 1.3 / 4.0 = 0.325
• So, the Rf values for the analytes (A) and (B) are 0.725 and 0.325
11
Dr. Santanu Chakravorty
Thin layer Chromatography
Different compounds in the sample mixture travel at different rates due to the
differences in their attraction to the stationary phase and because of differences in
solubility in the solvent. By changing the solvents, or perhaps using a mixture, the
separation of compounds can be adjusted. Chemists often use TLC to develop a
protocol for separation by chromatography and use TLC to determine which
fraction contain the desired compounds. Separation of compound is based on the
competition of the solute and the mobile phase for binding sites on the stationary
phase. For instances, if normal phase silica gel is used as the stationary phase, it
can be considered polar. Given two compounds that differ polarity, the more polar
compound has a stronger interaction with the silica and is, therefore, better able
to displace the mobile phase from the available binding sites. As a consequence,
the less polar compound moves higher up the plate.
12
Dr. Santanu Chakravorty
TLC Technique
• Thin layer chromatography technique used to separate non-volatile mixtures. This-
layer chromatography is performed on a sheet of glass, plastic or aluminum foil,
which is coated with a thin layer of adsorbent material, usually silica gel, aluminum
oxide. This layer of adsorbent is known as the stationary phase.
• After the sample has been applied on the plate, a solvent or solvent mixture is
drawn up the plate via capillary action. Because different analytes ascend the TLC
plate at different rates, separation is achieved. For example, with silica gel, a very
polar substances, non-polar mobile phase such as heptane is used.
• After the experiment, the spots are visualized. Often this can be done simply by
projecting ultraviolet light onto the sheet; the sheets are treated with a phosphor,
and dark spots appear on the sheets were compounds absorb light impinging on a
certain area.
• To quantify the results, the distance traveled by the substance being considered is
divided by the total distance traveled by the mobile phase. This ratio is called
retardation factor. In general, a substance whose structure resembles the
stationary phase will have low Rf, while one that has a similar structure to the
mobile phase will have high retardation factor.
13
Dr. Santanu Chakravorty
Difference between column chromatography
and thin layer chromatography
The main differences are:
• TLC has a stationary phase of alumina or silica gel. Column Chromatography is
packed uses its stationary phase with an appropriate matrix material, such as silica.
• TLC is carried for the against gravity. Column Chromatography is run under gravity.
• TLC uses for the analytical purpose. Column Chromatography uses for the
preparative purpose.
• Column Chromatography take more time to separate than TLC.
• TLC needs less quantity of solvent to separate the analytes . Column
chromatography required more amount of solvent.
• TLC needs more polar solvent compared to the column chromatography.
14
Dr. Santanu Chakravorty
Partition Chromatography
Partition Chromatography Principle
• In partition chromatography, the separation of the components from the sample
takes place through the process of partition the components between two phases,
where both the phases are present in liquid form. In this procedure, the
immiscible solid surface that is covered with the liquid surface on the stationary
phase is in the mobile phase.
• The stationary phase immobilizes the liquid surface which ultimately changes into
a stationary phase. The components are separated just after the mobile phase
shifts from the stationary phase. The separation is because of the differences in
partition coefficients.
15
Dr. Santanu Chakravorty
Technique
• For a simple comprehension of the partition chromatography, here we are explaining the procedure
for conducting paper chromatography.
Apparatus required:
• Chromatography jar, Capillary tube, Stationary phase
• Mobile phase – Chloroform, methanol, acetone, or ethanol
Steps:
• Selecting an appropriate type of development – Based on solvent, mixture, paper complexity, etc.
the type of development is selected. Usually ascending paper chromatography is utilized as it is a
simple technique to perform and also the chromatograms are quickly acquired.
• Choosing a stationary phase – Based on pores size and quality of the analyte, filter paper
(stationary phase) is chosen.
• Preparing the sample – The sample is prepared by dissolving the component in a proper solvent
that is employed during the procedure of producing mobile phases.
• Spotting the sample on paper – The sample mixture is applied on the filter paper at an appropriate
position.
• Developing the chromatogram – With the help of a chromatographic jar, the chromatogram
development is determined by drenching the paper into the solvent or mobile phase. Through the
capillary action, the mobile phase is allowed to run over the test sample.
• Paper drying and identifying the compounds – After the development of the chromatograms, the
filter paper is dried with the aid of an air dryer. Paper possessing different bands of molecules can
be studied in the UV cabinet. Rf values are also figured out.
16
Dr. Santanu Chakravorty
Ion Exchange Chromatography
• IEC is a type of liquid chromatography in which ions are separated by their adsorption onto a
support that contains fixed charges on its surface. This method relies on the interaction (or
exchange) of ions in the sample or mobile phase with fixed ionic groups of the opposite
charge that are bound to the support and act as the stationary phase. Depending on the
charge of the groups that make up the stationary phase, the types of ions that bind to the
column may be either cations (ie, positively charged ions) or anions (ie, negatively charged
ions). These two methods are referred to as cation-exchange chromatography and anion-
exchange chromatography, respectively. Supports for cation-exchange chromatography
contain negatively charged functional groups. These groups may be the conjugate bases of
strong acids, or the conjugate bases of weak acids. The supports used in anion-exchange
chromatography are usually the conjugate acids of strongly basic quaternary amines, or the
conjugate acids of weak bases.
• A strong mobile phase in IEC is usually a mobile phase that contains a high concentration of
competing ions. The presence of these competing ions will make it more difficult for a
charged analyte to bind to the fixed charges that act as the stationary phase. A weak mobile
phase in IEC is one that contains few or no competing ions or that otherwise promotes
binding by charged analytes to the column. Changing the competing ion concentration is the
most common approach for adjusting the retention of analyte ions in IEC. The retention of
ions in this method also may be affected by (1) pH, (2) the type of competing ion used, (3)
the type of fixed charges used as the stationary phase, and (4) the density of these fixed
charges on the support.
17
Dr. Santanu Chakravorty
Ion Exchange Chromatography Technique
Key steps in the ion exchange chromatography procedure are listed below:
• An impure protein sample is loaded into the ion exchange chromatography column
at a particular pH.
• Charged proteins will bind to the oppositely charged functional groups in the resin
• A salt gradient is used to elute separated proteins. At low salt concentrations,
proteins having few charged groups are eluted and at higher salt concentrations,
proteins with several charged groups are eluted.
• Unwanted proteins and impurities are removed by washing the column.
• A pH gradient can also be applied to elute individual proteins on the basis of their
isoelectric point (pI) i.e. the point at which the amino acids in a protein carry
neutral charge and hence do not migrate in an electric field. As amino acids are
zwitter ionic compounds they contain groups having both positive and negative
charges. Based on the pH of the environment, proteins carry a positive, negative,
or nil charge. At their isoelectric point, they will not interact with the charged
moieties in the column resin and hence are eluted. A decreasing pH gradient can
be used to elute proteins using an anion exchange resin and an increasing pH
gradient can be used to elute proteins from cation exchange resins.
18
Dr. Santanu Chakravorty
Gas-Liquid Chromatography
• GLC is a process by which a mixture is separated into its constituents by a moving
gas passing over a liquid stationary phase. Separation of the mixture into its
constituents occur by partitioning the sample between a mobile gas phase (known
as carrier gas) and a thin layer of non-volatile liquid coated on an inert support.
• A gas-liquid chromatograph consists of the following parts: A supply of carrier gas
from a high pressure cylinder, sample injection system and flow controller, the
column and the detector
19
The sample is introduced as a gas at the head of the column. As a result,
components having finite solubility in the stationary liquid phase distributed
themselves between this phase and the mobile gas phase, in accordance with
Dr. Santanu Chakravorty
Gas-Liquid Chromatography
equilibrium law. Elution is the carried out by forcing an inert gas (eg He, N2, H2 or
Ar) through the column. The rate of movement of the various component along
the column depends upon their tending to dissolve in the stationary liquid phase.
Components having negligible solubility in the stationary phase move more rapidly
through the column, while the components whose distribution coefficient favors
the solvent liquid phase move slowly through the column.
20
Typical chart record peaks corresponds to individual components detected
Dr. Santanu Chakravorty
Difference between GLC and Column
Chromatography
Gas chromatography is in principle similar to column chromatography, but has
several notable differences. First, the process of separating the compounds in a
mixture is carried out between a liquid-stationary phase and a gas mobile phase,
whereas in column chromatography the stationary phase is solid and mobile phase
is a liquid. Second, the column through which the gas phase passes is located in an
oven where the temperature of the gas can be controlled, whereas column
chromatography has no such temperature control. Finally the concentration of a
compound in the gas phase is solely function of the vapor pressure of the gas.
21
Dr. Santanu Chakravorty
High Performance liquid Chromatography
(HPLC)
The separation principle of HPLC is based on the distribution of the analyte
(sample) between a mobile phase (eluent) and a stationary phase (packing
material of the column). Depending on the chemical structure of the analyte, the
molecules are retarded while passing the stationary phase. The specific
intermolecular interactions between the molecules of a sample and the packing
material define their time “on-column”. Hence, different constituents of a sample
are eluted at different times. Thereby, the separation of the sample ingredients is
achieved. A detection unit (e.g. UV detector) recognizes the analytes after leaving
the column. The signals are converted and recorded by a data management system
(computer software) and then shown in a chromatogram. After passing the
detector unit, the mobile phase can be subjected to additional detector units, a
fraction collection unit or to the waste. In general, a HPLC system contains the
following modules: a solvent reservoir, a pump, an injection valve, a column, a
detector unit and a data processing unit. The solvent (eluent) is delivered by the
pump at high pressure and constant speed through the system. To keep the drift
and noise of the detector signal as low as possible, a constant and pulseless flow
from the pump is crucial. The analyte (sample) is provided to the eluent by the
injection valve.
22

More Related Content

What's hot

Isomerism class 11 CBSE organic chemistry some basic principles techniques
Isomerism class 11 CBSE organic chemistry some basic principles techniquesIsomerism class 11 CBSE organic chemistry some basic principles techniques
Isomerism class 11 CBSE organic chemistry some basic principles techniques
ritik
 
Lecture # 6 cost estimation ii
Lecture # 6 cost estimation iiLecture # 6 cost estimation ii
Lecture # 6 cost estimation ii
Bich Lien Pham
 
Crystal field theory
Crystal field theoryCrystal field theory
Crystal field theory
surya287
 
Nano plastic
Nano plasticNano plastic
Nano plastic
moradwael
 
The determination of point groups
The determination of point groupsThe determination of point groups
The determination of point groups
ZuhriyatusSholichah
 

What's hot (20)

Polyphenylene Sulfide(PPS)
Polyphenylene Sulfide(PPS)Polyphenylene Sulfide(PPS)
Polyphenylene Sulfide(PPS)
 
Isomerism class 11 CBSE organic chemistry some basic principles techniques
Isomerism class 11 CBSE organic chemistry some basic principles techniquesIsomerism class 11 CBSE organic chemistry some basic principles techniques
Isomerism class 11 CBSE organic chemistry some basic principles techniques
 
CHAPTER 3 POLYMERIZATION.ppt
CHAPTER 3 POLYMERIZATION.pptCHAPTER 3 POLYMERIZATION.ppt
CHAPTER 3 POLYMERIZATION.ppt
 
Activated carbon
Activated carbonActivated carbon
Activated carbon
 
Types of polymerization
Types of polymerizationTypes of polymerization
Types of polymerization
 
Polymer
Polymer Polymer
Polymer
 
Arenes and aromaticity
Arenes and aromaticityArenes and aromaticity
Arenes and aromaticity
 
Stereoisomerism
StereoisomerismStereoisomerism
Stereoisomerism
 
Polymerization process or synthesis by Dr. Salma Amir
Polymerization process or synthesis by Dr. Salma AmirPolymerization process or synthesis by Dr. Salma Amir
Polymerization process or synthesis by Dr. Salma Amir
 
Topicity
TopicityTopicity
Topicity
 
Lecture # 6 cost estimation ii
Lecture # 6 cost estimation iiLecture # 6 cost estimation ii
Lecture # 6 cost estimation ii
 
Stereoselective and stereospecific reactions
Stereoselective and stereospecific reactionsStereoselective and stereospecific reactions
Stereoselective and stereospecific reactions
 
Crystal field theory
Crystal field theoryCrystal field theory
Crystal field theory
 
Nano plastic
Nano plasticNano plastic
Nano plastic
 
Polymer
Polymer Polymer
Polymer
 
Effective Atomic Number (EAN)
Effective Atomic Number (EAN)Effective Atomic Number (EAN)
Effective Atomic Number (EAN)
 
plastic
plasticplastic
plastic
 
polystyrene
polystyrenepolystyrene
polystyrene
 
The determination of point groups
The determination of point groupsThe determination of point groups
The determination of point groups
 
Introduction to inorganic polymers by Dr. Salma AMIR
Introduction to inorganic polymers by Dr. Salma AMIRIntroduction to inorganic polymers by Dr. Salma AMIR
Introduction to inorganic polymers by Dr. Salma AMIR
 

Similar to DSE-2, ANALYTICAL METHODS -Ch-II.pptx

Introduction to chromatography and its applications 2
Introduction to chromatography and its applications 2Introduction to chromatography and its applications 2
Introduction to chromatography and its applications 2
Kalsoom Mohammed
 
Classification of Chromatography
Classification of ChromatographyClassification of Chromatography
Classification of Chromatography
khadeeja ikram01
 
CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.
CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.
CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.
PiyashiDas
 

Similar to DSE-2, ANALYTICAL METHODS -Ch-II.pptx (20)

Classification of chromatography
Classification of chromatographyClassification of chromatography
Classification of chromatography
 
Introduction to chromatography
Introduction to chromatographyIntroduction to chromatography
Introduction to chromatography
 
Chromatography.pptx
Chromatography.pptxChromatography.pptx
Chromatography.pptx
 
Separation methods
Separation methodsSeparation methods
Separation methods
 
Introduction to chromatography and its applications 2
Introduction to chromatography and its applications 2Introduction to chromatography and its applications 2
Introduction to chromatography and its applications 2
 
Introduction of chromatography.pptx
Introduction of chromatography.pptxIntroduction of chromatography.pptx
Introduction of chromatography.pptx
 
Chromatography.pdf
Chromatography.pdfChromatography.pdf
Chromatography.pdf
 
Classification of chromatography
Classification of chromatographyClassification of chromatography
Classification of chromatography
 
Chromotography
ChromotographyChromotography
Chromotography
 
chromotography-140516031516-phpapp02.pdf
chromotography-140516031516-phpapp02.pdfchromotography-140516031516-phpapp02.pdf
chromotography-140516031516-phpapp02.pdf
 
Classification of Chromatography
Classification of ChromatographyClassification of Chromatography
Classification of Chromatography
 
SEM5-CHROMATOGRAPHY.pptx
SEM5-CHROMATOGRAPHY.pptxSEM5-CHROMATOGRAPHY.pptx
SEM5-CHROMATOGRAPHY.pptx
 
Chromatography, types by different approaches, HPLC
Chromatography, types by  different approaches, HPLC Chromatography, types by  different approaches, HPLC
Chromatography, types by different approaches, HPLC
 
Introduction to chromatography
Introduction to chromatographyIntroduction to chromatography
Introduction to chromatography
 
chromatography.pptx
chromatography.pptxchromatography.pptx
chromatography.pptx
 
Chromatnogy.pptx
Chromatnogy.pptxChromatnogy.pptx
Chromatnogy.pptx
 
Chromatography
ChromatographyChromatography
Chromatography
 
Chromatography introduction
Chromatography introductionChromatography introduction
Chromatography introduction
 
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdfChapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
Chapter-6-ADSORPTION-PARTITION-CHROMATOGRAPHY.pdf
 
CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.
CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.
CHROMATOGRAPHY - PRINCIPLE,APPLICATIONS.
 

More from Mathabhanga College (8)

Chemical explosives.pptx
Chemical explosives.pptxChemical explosives.pptx
Chemical explosives.pptx
 
Paints.pptx
Paints.pptxPaints.pptx
Paints.pptx
 
glass.pptx
glass.pptxglass.pptx
glass.pptx
 
Cement.pptx
Cement.pptxCement.pptx
Cement.pptx
 
DSE-2, ANALYTICAL METHODS.pptx
DSE-2, ANALYTICAL METHODS.pptxDSE-2, ANALYTICAL METHODS.pptx
DSE-2, ANALYTICAL METHODS.pptx
 
Pharmaceutical Chemistry - Last part.pptx
Pharmaceutical Chemistry - Last part.pptxPharmaceutical Chemistry - Last part.pptx
Pharmaceutical Chemistry - Last part.pptx
 
Pharma New-1.pdf
Pharma New-1.pdfPharma New-1.pdf
Pharma New-1.pdf
 
Pharmaceutical Chemistry.pptx
Pharmaceutical Chemistry.pptxPharmaceutical Chemistry.pptx
Pharmaceutical Chemistry.pptx
 

Recently uploaded

Cyathodium bryophyte: morphology, anatomy, reproduction etc.
Cyathodium bryophyte: morphology, anatomy, reproduction etc.Cyathodium bryophyte: morphology, anatomy, reproduction etc.
Cyathodium bryophyte: morphology, anatomy, reproduction etc.
Cherry
 
Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.
Cherry
 
Digital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptxDigital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptx
MohamedFarag457087
 
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
Scintica Instrumentation
 
POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.
Cherry
 
Module for Grade 9 for Asynchronous/Distance learning
Module for Grade 9 for Asynchronous/Distance learningModule for Grade 9 for Asynchronous/Distance learning
Module for Grade 9 for Asynchronous/Distance learning
levieagacer
 
Human genetics..........................pptx
Human genetics..........................pptxHuman genetics..........................pptx
Human genetics..........................pptx
Cherry
 
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Sérgio Sacani
 

Recently uploaded (20)

FAIRSpectra - Enabling the FAIRification of Analytical Science
FAIRSpectra - Enabling the FAIRification of Analytical ScienceFAIRSpectra - Enabling the FAIRification of Analytical Science
FAIRSpectra - Enabling the FAIRification of Analytical Science
 
Cyathodium bryophyte: morphology, anatomy, reproduction etc.
Cyathodium bryophyte: morphology, anatomy, reproduction etc.Cyathodium bryophyte: morphology, anatomy, reproduction etc.
Cyathodium bryophyte: morphology, anatomy, reproduction etc.
 
Site Acceptance Test .
Site Acceptance Test                    .Site Acceptance Test                    .
Site Acceptance Test .
 
Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.
 
Digital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptxDigital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptx
 
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
 
POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.POGONATUM : morphology, anatomy, reproduction etc.
POGONATUM : morphology, anatomy, reproduction etc.
 
Site specific recombination and transposition.........pdf
Site specific recombination and transposition.........pdfSite specific recombination and transposition.........pdf
Site specific recombination and transposition.........pdf
 
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICEPATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
PATNA CALL GIRLS 8617370543 LOW PRICE ESCORT SERVICE
 
Module for Grade 9 for Asynchronous/Distance learning
Module for Grade 9 for Asynchronous/Distance learningModule for Grade 9 for Asynchronous/Distance learning
Module for Grade 9 for Asynchronous/Distance learning
 
Concept of gene and Complementation test.pdf
Concept of gene and Complementation test.pdfConcept of gene and Complementation test.pdf
Concept of gene and Complementation test.pdf
 
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRLGwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
 
Plasmid: types, structure and functions.
Plasmid: types, structure and functions.Plasmid: types, structure and functions.
Plasmid: types, structure and functions.
 
FS P2 COMBO MSTA LAST PUSH past exam papers.
FS P2 COMBO MSTA LAST PUSH past exam papers.FS P2 COMBO MSTA LAST PUSH past exam papers.
FS P2 COMBO MSTA LAST PUSH past exam papers.
 
Human genetics..........................pptx
Human genetics..........................pptxHuman genetics..........................pptx
Human genetics..........................pptx
 
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
 
Cyanide resistant respiration pathway.pptx
Cyanide resistant respiration pathway.pptxCyanide resistant respiration pathway.pptx
Cyanide resistant respiration pathway.pptx
 
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptxClimate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
 
module for grade 9 for distance learning
module for grade 9 for distance learningmodule for grade 9 for distance learning
module for grade 9 for distance learning
 
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIACURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
 

DSE-2, ANALYTICAL METHODS -Ch-II.pptx

  • 1. Dr. Santanu Chakravorty CHEMISTRY-DSE: ANALYTICAL METHODS IN CHEMISTRY Dr. Santanu Chakravorty Assistant Professor Mathabhanga College 1
  • 2. Dr. Santanu Chakravorty Syllabus Chromatography: Classification, principle and efficiency of the technique. Mechanism of separation: adsorption, partition & ion exchange. Development of chromatograms: frontal, elution and displacement methods. Qualitative and quantitative aspects of chromatographic methods of analysis: IC, GLC, GPC, TLC and HPLC 2
  • 3. Dr. Santanu Chakravorty Principles of Chromatography Chromatography now refers to any of a diverse group of techniques that effect a separation through a distribution of sample between two immiscible phases. The requirement to distinguish chromatography from other separation technique is that one phase be stationary while the second phase be mobile and percolating through the first phase resulting in selective retention of the components of a mixture by the stationary phase. The stationary phase which may be solid or liquid or may consists of a mixture of a solid and liquid , is finely divided and is fixed in place. The mobile phase, which may be liquid or gaseous, fills the interstices of the stationary phase and is able to flow through the stationary phase. The physical states of the mobile and stationary phases give rise to four basic type of chromatography i. liquid-solid chromatography, (LSC) ii. Liquid-liquid chromatography, (LLC) iii. Gas- liquid chromatography, (GLC) iv. Gas-solid chromatography (GSC) Solid stationary phase also gives rise to low exchange chromatography. Separation of the components, or solutes of a sample results from differences in their rate of adsorption. 3
  • 4. Dr. Santanu Chakravorty Classification • The purpose of applying chromatography which is used as a method of quantitative analysis apart from its separation, is to achieve a satisfactory separation within a suitable time interval. Various chromatography methods have been developed to that end. Some of them include column chromatography, thin-layer chromatography (TLC), paper chromatography, gas chromatography, ion exchange chromatography, gel permeation chromatography, high- pressure liquid chromatography, and affinity chromatography. Types of chromatography • Column chromatography • Ion-exchange chromatography • Gel-permeation (molecular sieve) chromatography • Affinity chromatography • Paper chromatography • Thin-layer chromatography • Gas chromatography • Dye-ligand chromatography • Hydrophobic interaction chromatography • Pseudoaffinity chromatography • High-pressure liquid chromatography (HPLC) 4
  • 5. Dr. Santanu Chakravorty Efficiency of Chromatography techniques Chromatographic methods will separate ionic species, inorganic or organic, and molecular species ranging in size from the lightest and smallest, helium and hydrogen, to particulate matter such as single cells . No single configuration will accomplish this, however. Little preknowledge of the constituent of a mixture is required. At its best, chromatography will separate several hundreds of components of unknown identity and unknown concentrations, leaving the components unchanged. Amounts in the parts per billion range can be detected with some detectors. The solute can range from polar to nonpolar—i.e., water-soluble to hydrocarbon-soluble. • Substances of low critical temperature or low molecular weight, such as the gases at laboratory conditions showing dispersive or London intermolecular forces only, are separated with molecular sieves or gas-solid techniques. Gas-liquid chromatography is applicable to species with high critical temperatures and normal boiling points as high as 400 °C. Substances that are solids at normal laboratory conditions with molecular weights below 1,000 are best separated with liquid-solid or liquid-liquid systems. Lower members of the molecular weight scale range are amenable to supercritical fluid separations. Size- exclusion methods are involved at molecular weights above 1,000. Field-flow fractionation extends the size range to colloids and microscopic particles. • Separations are fast, ranging from analysis times of a few minutes to several hours. The prechromatographic world would have considered a time of several hours to separate multicomponent mixtures to be miraculously fast. Now several hours is considered excessive, and there is much emphasis on increasing speed. 5
  • 6. Dr. Santanu Chakravorty Adsorption Chromatography Adsorption chromatography is a type of LC in which chemicals are retained based on their adsorption and desorption at the surface of the support, which also acts as the stationary phase. This method is also sometimes referred to as liquid-solid chromatography. Retention in this method is based on the competition of the analyte with molecules of the mobile phase as both bind to the surface of the support. The degree of a chemical's retention in adsorption chromatography will depend on (1) the binding strength of this chemical to the support, (2) the surface area of the support, (3) the amount of mobile phase displaced from the support by the chemical, and (4) the binding strength of the mobile phase to the support. Electrostatic interactions, hydrogen bonding, dipole-dipole interactions, and dispersive interactions (ie, van der Waals forces) all may affect retention in this type of chromatography. The binding strength of the mobile phase with the support in adsorption chromatography is described by the mobile phase's elutropic strength. A liquid or solution that has a large elutropic strength for a given support will act as a strong mobile phase for that material because this mobile phase will tend to bind tightly to the support and cause the analyte to elute more quickly as it spends more time in the mobile phase. As an example, a relatively polar solvent such as methanol will have higher elutropic strength for a polar support such as silica than a nonpolar solvent such as carbon tetrachloride. In the same manner, a liquid or solution that has a low elutropic strength for a support would represent a weak mobile phase for that support in adsorption chromatography (eg, carbon tetrachloride on silica). Three types of adsorbents are generally used in adsorption chromatography: (1) polar acidic supports, (2) polar basic supports, and (3) nonpolar supports. The most common polar and acidic support used in adsorption chromatography is silica. The surface silanol groups on this support tend to adsorb polar compounds and work particularly well for basic substances. Alumina is the main type of polar and basic adsorbent that is used in adsorption chromatography. Like silica, alumina retains polar compounds, but alumina works especially well for polar acidic substances. Other types of supports that can be used in adsorption chromatography are nonpolar adsorbents such as charcoal and polystyrene. 6
  • 7. Dr. Santanu Chakravorty Column Chromatography Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential adsorption of compounds to the adsorbent. Compounds move through the column at different rates, allowing them to be separated in fractions. The technique is widely applicable, as many different adsorbents can be used with a wide range of solvents. The technique can be used on scales from micrograms up to kilograms. The main advantage of column chromatography is the relatively low cost and disposability of the stationary phase used in the process. The latter prevents cross contamination and stationary phase degradation due to recycling column chromatography can be done using gravity to move solvent, or using compressed gas to push the solvent through the column. 7 •In column chromatography the stationary phase is packed into a glass or metal column. •The mixture of analytes is then applied and the mobile phase, commonly referred to as the eluent, is passed through the column either by use of a pumping system or applied gas pressure. •The stationary phase is either coated onto discrete small particles (the matrix) and packed into the column or applied as a thin film to the inside wall of the column. •As the eluent flows through the column the analytes separate on the basis of their distribution coefficients and emerge individually in the eluate as it leaves the column.
  • 8. Dr. Santanu Chakravorty Column Chromatography Technique • Column chromatography is a technique in which the substances to be separated are introduced onto the top of a column packed with an adsorbent, passed through the column at different rates that depend on the affinity of each substance for the adsorbent and for the solvent or solvent mixture, and are usually collected in solution as they pass from the column at different times. • It is a solid-liquid technique in which the stationary phase is a solid & the mobile phase is a liquid or gas. • It was developed by the American chemist D.T Day in 1900 while M.S. Tswett, the Polish botanist, 1906 used adsorption columns in his investigations of plant pigments. 8
  • 9. Dr. Santanu Chakravorty Elution, Eluent and Rf value In a liquid chromatography experiment for example an analyte is generally adsorbed, or bound to an adsorbent in a liquid chromatography column. The adsorbent, a solid phase, is a powder which is coated onto a solid support. Based on an adsorbents composition, it can have varying affinities to hold onto other molecules-forming a thin film on its surface. Elution then is the process of removing analytes from the adsorbent by running a solvents, called an eluent pass the adsorbent/ analyte complex. The eluent is the carrier portion of the mobile phase. It moves the analytes through the chromatograph. In liquid chromatography, the eluent is the liquid solvent, in gas chromatography, it is carrier gas. 9
  • 10. Dr. Santanu Chakravorty Elution, Eluent and Rf value Rf is the retardation factor, which is the ratio of the distance traveled by a compound in a mobile phase compared with the distance traveled by the front of the mobile phase itself. It is always greater than or equal to zero, and less than equal to 1. • A chromatogram is first to be developed with a suitable solvent (mobile phase), depending upon the nature of analytes, and the stationary phases. The developed chromatogram is then dried and the positions (migration values) are measured for analytes and the solvent front. The Rf (retardation/retention factor) values can be calculated by using the given procedure using the above experiment. • A prepared sample solution (A+B) is applied on the chromatogram paper and run through a mobile phase. Analyte (A) and (B) separate out because of different affinities with mobile phase (solvent). The relative measurements are taken for the analytes, the solvent front, and the point where the mixture (A+B) was applied. 10
  • 11. Dr. Santanu Chakravorty Rf value calculation • For the analyte (A) • Rf = Distance moved by analyte (A) / Distance moved by solvent front Rf = 2.9 / 4.0 = 0.725 • For the analyte (B) • Rf = Distance moved by analyte (B) / Distance moved by solvent front Rf = 1.3 / 4.0 = 0.325 • So, the Rf values for the analytes (A) and (B) are 0.725 and 0.325 11
  • 12. Dr. Santanu Chakravorty Thin layer Chromatography Different compounds in the sample mixture travel at different rates due to the differences in their attraction to the stationary phase and because of differences in solubility in the solvent. By changing the solvents, or perhaps using a mixture, the separation of compounds can be adjusted. Chemists often use TLC to develop a protocol for separation by chromatography and use TLC to determine which fraction contain the desired compounds. Separation of compound is based on the competition of the solute and the mobile phase for binding sites on the stationary phase. For instances, if normal phase silica gel is used as the stationary phase, it can be considered polar. Given two compounds that differ polarity, the more polar compound has a stronger interaction with the silica and is, therefore, better able to displace the mobile phase from the available binding sites. As a consequence, the less polar compound moves higher up the plate. 12
  • 13. Dr. Santanu Chakravorty TLC Technique • Thin layer chromatography technique used to separate non-volatile mixtures. This- layer chromatography is performed on a sheet of glass, plastic or aluminum foil, which is coated with a thin layer of adsorbent material, usually silica gel, aluminum oxide. This layer of adsorbent is known as the stationary phase. • After the sample has been applied on the plate, a solvent or solvent mixture is drawn up the plate via capillary action. Because different analytes ascend the TLC plate at different rates, separation is achieved. For example, with silica gel, a very polar substances, non-polar mobile phase such as heptane is used. • After the experiment, the spots are visualized. Often this can be done simply by projecting ultraviolet light onto the sheet; the sheets are treated with a phosphor, and dark spots appear on the sheets were compounds absorb light impinging on a certain area. • To quantify the results, the distance traveled by the substance being considered is divided by the total distance traveled by the mobile phase. This ratio is called retardation factor. In general, a substance whose structure resembles the stationary phase will have low Rf, while one that has a similar structure to the mobile phase will have high retardation factor. 13
  • 14. Dr. Santanu Chakravorty Difference between column chromatography and thin layer chromatography The main differences are: • TLC has a stationary phase of alumina or silica gel. Column Chromatography is packed uses its stationary phase with an appropriate matrix material, such as silica. • TLC is carried for the against gravity. Column Chromatography is run under gravity. • TLC uses for the analytical purpose. Column Chromatography uses for the preparative purpose. • Column Chromatography take more time to separate than TLC. • TLC needs less quantity of solvent to separate the analytes . Column chromatography required more amount of solvent. • TLC needs more polar solvent compared to the column chromatography. 14
  • 15. Dr. Santanu Chakravorty Partition Chromatography Partition Chromatography Principle • In partition chromatography, the separation of the components from the sample takes place through the process of partition the components between two phases, where both the phases are present in liquid form. In this procedure, the immiscible solid surface that is covered with the liquid surface on the stationary phase is in the mobile phase. • The stationary phase immobilizes the liquid surface which ultimately changes into a stationary phase. The components are separated just after the mobile phase shifts from the stationary phase. The separation is because of the differences in partition coefficients. 15
  • 16. Dr. Santanu Chakravorty Technique • For a simple comprehension of the partition chromatography, here we are explaining the procedure for conducting paper chromatography. Apparatus required: • Chromatography jar, Capillary tube, Stationary phase • Mobile phase – Chloroform, methanol, acetone, or ethanol Steps: • Selecting an appropriate type of development – Based on solvent, mixture, paper complexity, etc. the type of development is selected. Usually ascending paper chromatography is utilized as it is a simple technique to perform and also the chromatograms are quickly acquired. • Choosing a stationary phase – Based on pores size and quality of the analyte, filter paper (stationary phase) is chosen. • Preparing the sample – The sample is prepared by dissolving the component in a proper solvent that is employed during the procedure of producing mobile phases. • Spotting the sample on paper – The sample mixture is applied on the filter paper at an appropriate position. • Developing the chromatogram – With the help of a chromatographic jar, the chromatogram development is determined by drenching the paper into the solvent or mobile phase. Through the capillary action, the mobile phase is allowed to run over the test sample. • Paper drying and identifying the compounds – After the development of the chromatograms, the filter paper is dried with the aid of an air dryer. Paper possessing different bands of molecules can be studied in the UV cabinet. Rf values are also figured out. 16
  • 17. Dr. Santanu Chakravorty Ion Exchange Chromatography • IEC is a type of liquid chromatography in which ions are separated by their adsorption onto a support that contains fixed charges on its surface. This method relies on the interaction (or exchange) of ions in the sample or mobile phase with fixed ionic groups of the opposite charge that are bound to the support and act as the stationary phase. Depending on the charge of the groups that make up the stationary phase, the types of ions that bind to the column may be either cations (ie, positively charged ions) or anions (ie, negatively charged ions). These two methods are referred to as cation-exchange chromatography and anion- exchange chromatography, respectively. Supports for cation-exchange chromatography contain negatively charged functional groups. These groups may be the conjugate bases of strong acids, or the conjugate bases of weak acids. The supports used in anion-exchange chromatography are usually the conjugate acids of strongly basic quaternary amines, or the conjugate acids of weak bases. • A strong mobile phase in IEC is usually a mobile phase that contains a high concentration of competing ions. The presence of these competing ions will make it more difficult for a charged analyte to bind to the fixed charges that act as the stationary phase. A weak mobile phase in IEC is one that contains few or no competing ions or that otherwise promotes binding by charged analytes to the column. Changing the competing ion concentration is the most common approach for adjusting the retention of analyte ions in IEC. The retention of ions in this method also may be affected by (1) pH, (2) the type of competing ion used, (3) the type of fixed charges used as the stationary phase, and (4) the density of these fixed charges on the support. 17
  • 18. Dr. Santanu Chakravorty Ion Exchange Chromatography Technique Key steps in the ion exchange chromatography procedure are listed below: • An impure protein sample is loaded into the ion exchange chromatography column at a particular pH. • Charged proteins will bind to the oppositely charged functional groups in the resin • A salt gradient is used to elute separated proteins. At low salt concentrations, proteins having few charged groups are eluted and at higher salt concentrations, proteins with several charged groups are eluted. • Unwanted proteins and impurities are removed by washing the column. • A pH gradient can also be applied to elute individual proteins on the basis of their isoelectric point (pI) i.e. the point at which the amino acids in a protein carry neutral charge and hence do not migrate in an electric field. As amino acids are zwitter ionic compounds they contain groups having both positive and negative charges. Based on the pH of the environment, proteins carry a positive, negative, or nil charge. At their isoelectric point, they will not interact with the charged moieties in the column resin and hence are eluted. A decreasing pH gradient can be used to elute proteins using an anion exchange resin and an increasing pH gradient can be used to elute proteins from cation exchange resins. 18
  • 19. Dr. Santanu Chakravorty Gas-Liquid Chromatography • GLC is a process by which a mixture is separated into its constituents by a moving gas passing over a liquid stationary phase. Separation of the mixture into its constituents occur by partitioning the sample between a mobile gas phase (known as carrier gas) and a thin layer of non-volatile liquid coated on an inert support. • A gas-liquid chromatograph consists of the following parts: A supply of carrier gas from a high pressure cylinder, sample injection system and flow controller, the column and the detector 19 The sample is introduced as a gas at the head of the column. As a result, components having finite solubility in the stationary liquid phase distributed themselves between this phase and the mobile gas phase, in accordance with
  • 20. Dr. Santanu Chakravorty Gas-Liquid Chromatography equilibrium law. Elution is the carried out by forcing an inert gas (eg He, N2, H2 or Ar) through the column. The rate of movement of the various component along the column depends upon their tending to dissolve in the stationary liquid phase. Components having negligible solubility in the stationary phase move more rapidly through the column, while the components whose distribution coefficient favors the solvent liquid phase move slowly through the column. 20 Typical chart record peaks corresponds to individual components detected
  • 21. Dr. Santanu Chakravorty Difference between GLC and Column Chromatography Gas chromatography is in principle similar to column chromatography, but has several notable differences. First, the process of separating the compounds in a mixture is carried out between a liquid-stationary phase and a gas mobile phase, whereas in column chromatography the stationary phase is solid and mobile phase is a liquid. Second, the column through which the gas phase passes is located in an oven where the temperature of the gas can be controlled, whereas column chromatography has no such temperature control. Finally the concentration of a compound in the gas phase is solely function of the vapor pressure of the gas. 21
  • 22. Dr. Santanu Chakravorty High Performance liquid Chromatography (HPLC) The separation principle of HPLC is based on the distribution of the analyte (sample) between a mobile phase (eluent) and a stationary phase (packing material of the column). Depending on the chemical structure of the analyte, the molecules are retarded while passing the stationary phase. The specific intermolecular interactions between the molecules of a sample and the packing material define their time “on-column”. Hence, different constituents of a sample are eluted at different times. Thereby, the separation of the sample ingredients is achieved. A detection unit (e.g. UV detector) recognizes the analytes after leaving the column. The signals are converted and recorded by a data management system (computer software) and then shown in a chromatogram. After passing the detector unit, the mobile phase can be subjected to additional detector units, a fraction collection unit or to the waste. In general, a HPLC system contains the following modules: a solvent reservoir, a pump, an injection valve, a column, a detector unit and a data processing unit. The solvent (eluent) is delivered by the pump at high pressure and constant speed through the system. To keep the drift and noise of the detector signal as low as possible, a constant and pulseless flow from the pump is crucial. The analyte (sample) is provided to the eluent by the injection valve. 22