SlideShare uma empresa Scribd logo
1 de 146
Baixar para ler offline
1
1
1
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
2
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
SUN产品介绍
北京华胜天成科技股份有限公司
2005年
www.sun.com/servers
3
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun 产品概述
SUN产品的分类(工作站、服务器、存储等产品)
www.sun.com/servers
4
4
4
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire 工作站/服务器产品家族
SF E2900
SF V1280
SF E4900
SF 4800
SF E6900
SF 6800
SF E20K
SF 15K
SF 25K
SF 15K
Netra 120
Netra 240
Netra 20
Netra440
Netra 1280
SF V120
SF V210 SF V240
SF F280
SF V250
SF V440
SF V490
SF V480
SF V890
SF V880
Sun Ray
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
SF V20z/V40z
SF V60x
SF V65x
SF Blade 1600
B100x&B200x
高端/中档
服务器
电信特性
服务器
入门级
服务器
瘦客户端工作站
服务器
X86 Linux
服务器
Sun W1100z
/W2100z
5
5
5
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 磁盘阵列家族
Sun StorEdge
9000 Family
Sun StorEdge
6000 Series
Sun StorEdge
3000 Family
Mission-Critical
Availability
Consolidation:
Mission-critical availability
for large consolidations
Essential
Value
Scalability
Performance:
Managed performance/
availability for
SAN environments
Operational
Flexibility
Simplicity:
Dense, reliable storage
for entry-level deployment
Data
Classification
ranked from
lowest
capital and
administrative
costs
Enables enterprise
virtualization and
provisioning, lowering
TCO
Heterogeneit
y
N1TM Data Services Platform
6
6
6
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 磁带库产品家族
Sun StorEdge
L25, L100, L180
Capacity,
Performanc
e, Retention
& Restore
Time
Sun StorEdge
L700, L5500/6000
Sun StorEdge stand
alone drives, L8
Workgroup Backup
Scalability, Flexibility
For mid-sized business
or departments
2.5TB to 34.8 TB
Local Backup
Small footprint
Entry level pricing for small
business or departments
20 GB to 1.6 TB
Consolidated Backup
Massively Scalable
Fabric SANs for the
enterprise 69TB to 1.1PB
7
7
7
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 光纤交换机家族
8
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun 产品概述
SUN 工作站
www.sun.com/servers
9
9
9
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 工作站
10
10
10
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire X86 and Linux 批量服务器
11
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun 产品概述
SUN 入门级服务器
www.sun.com/servers
12
12
12
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 批量服务器(一)
13
13
13
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 批量服务器(二)
14
14
14
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
中档、高端企业级和数据中心级服务器
15
15
15
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
新的UltraSPARC IV 多线程CMT企业级和数据
中心级服务器
16
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun 产品概述
SUN 电信特性服务器
www.sun.com/servers
17
17
17
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 电信特性(Netra)服务器
18
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun 产品概述
SUN 中高端服务器
www.sun.com/servers
19
19
19
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Ultra SPARC III
Sun Fire
4800
Sun Fire
V1280/Netra 1280
Sun Fire
6800
Sun Fire
12K
Sun Fire
15K
Sun Fire
E2900
Sun Fire
E4900
Sun Fire
E6900
Sun Fire
E20K
Sun Fire
E25K
SUN 中高端服务器产品线
● 12,700 Solaris 应用
● 通用部件, 包括CPU/内存板
● 统一的体系架构
● 二进制兼容
NEW
Ultra SPARC IV
20
20
20
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire 1280/4800/6800/12K/15K Server
• Base on UltraSPARC III Cu
• Support 1.2/1.35GHz UltraSPARC IV with
UltraSPARC s400 Uniboard, Solaris 8 2/04,
Solaris 9 4/04, SC firmware 5.16 or later, and
hardwire upgrade kit
21
21
21
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
介绍 Sun Fire
E2900,
E4900, E6900, E20K, and E25K Servers
• UltraSPARC IV Uniboards系统板
– 4个处理器,8个并发线程
– 32 GB 内存
• Sun Fire E20K /25K 服务器增强的I/O
– 新扩展板
– 新热交换 hsPCI+ I/O 集合
– 提高60% I/O 性能
22
22
22
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire E20K and E25K Servers
• 新的高带宽Sun Fireplane扩展板
• 新 hsPCI+ I/O 集合
• 增强的 I/O 性能
– hsPCI集合达到 60% 的吞吐量提高
• 增加66 MHz PCI slots数量
– hsPCI+ I/O 集合支持3x 33/66MHz slots, 1x 33 MHz
– Sun Fire E25K支持 54x66 MHz
高吞吐量 I/O
23
23
23
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
完全二进制兼容服务器
Sun Fire E4900
●Up to 12
UltraSPARC IV
processors, 24
concurrent threads
●Up to 96GB RAM
●16 PCI slots
●1 or 2 Domains
●9.6 GB/s Sustained
bandwidth
●Rack mount system
(1 per rack) or
deskside
●SRS Netconnect
●Solaris 8 and up
Sun Fire
E6900
●Up to 24
UltraSPARC IV
processors, 48
concurrent threads
●Up to 192GB RAM
●32 PCI slots
●1 to 4 Domains
●9.6 GB/s Sustained
bandwidth
●Datacenter rack
●SRS Netconnect
●Solaris 8 and up
Sun Fire E25K
●Up to 72
UltraSPARC IV
processors, 144
concurrent threads
●Up to 576GB RAM
●72 hot swap PCI+
slots
●1 to 18 Domains
●172.8 GB/s Peak
bandwidth (57
GB sustained)
●Datacenter rack
●SRS Netconnect
●Solaris 8 and up
Sun Fire E20K
●Up to 36
UltraSPARC IV
processors, 72
concurrent threads
●Up to 288 GB RAM
●36 hot swap PCI+
slots
●1 to 9 Domains
●86.4 GB/s Peak
bandwidth (29
GB sustained)
●Datacenter rack
●SRS Netconnect
●Solaris 8 and up
Sun Fire
E2900
●Up to 12
UltraSPARC IV
processors, 24
concurrent threads
●Up to 96GB RAM
●6 PCI slots, 2
internal disks
●9.6 GB/s Sustained
bandwidth
●Rugged, Compact
●Rack- Optimized
●SRS Netconnect
●Solaris 8 and up
Solaris Operating System
24
24
24
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Common Components
CPU/Memory Uniboard
PCI Card
System Controller
I/O Assembly
Sun
Fireplane Board
Fans
Power Supply
Sun Fire
E20K
Sun Fire
E25K
Sun Fire
E4900
Sun Fire
E6900
Unique
Unique Unique
Unique
25
25
25
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
空前的投资保护
• 完全的二进制兼容
– 支持 Solaris 8和 9 操作系统
• Board-level upgrades
– UltraSPARC IV Uniboards run in Sun Fire V1280-15K servers*
– UltraSPARC III Uniboards run in Sun Fire E2900-E25K servers
– Mixed-speed CPU support (UltraSPARC III and IV Uniboards)
– Mix and match Uniboards in same or separate domains
– System level upgrades
– Full factory-integration and testing
*Other hardware and software upgrades required; V1280/E2900 use CPU/memory boards
不需要应用和操作系统迁移
26
26
26
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
全部硬件冗余
冗余的,热交换的部件
• N+1 redundant subsystems
Failures don't affect operation
Examples: System Controllers, system clock, power supplies,
and fans
• Redundant components
Stable recovery from failures
Examples: Uniboard CPU/memory boards, I/O assemblies, Sun
Fireplane interconnect ASICS
Automatic System Recovery (ASR)
• Redundant I/O paths (both network and disk)
27
27
27
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
第五代动态系统域
• 域间错误隔离
• 域间资源动态重配置以适应应
用需求
• CPUs 、memory 重配置不依
赖 I/O
28
28
28
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
服务器虚拟化
A
P
P
S
A
P
P
S
A
P
P
S
A
P
P
S
A
P
P
S
A
P
P
S
A
P
P
S
Solaris 8 Solaris 9 Solaris 10
Domain 1 Domain 2 Domain 3
Server
A
P
P
S
Containers
A
P
P
S
安全
错误隔离
提高资源利用
动态系统域
每一个层次: 硬件, 操作系统, 应用软件
29
29
29
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
第五代动态重配置
• 从一个运行的域中动态地增加和移去部件
– CPU/Memory 板, PCI 卡, 和整个 I/O 集合
– 操作系统和应用程序继续运行无需重启动
– 在线维护、在线CPU/内存等板卡升级,支持不同速率
的CPU混用
• WBEM-based Dynamic Reconfiguration
(WDR)基于浏览器的动态重配
– 新的发展,工业标准的基于Web的企业系统管理
– 不同域之间资源的自动调整
– 预定的和可编程的资源调配方法
30
30
30
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Solaris
Trusted Containers*
• 虚拟的 OS service ,具有安全边界
• 容器(Containers)作为单独的Solaris
实例(Instance)
• 应用隔离
• 提取系统的每个细节,进行客户化的容器
管理
• 没有专用的系统资源 – 任意粒度级管理
Optimizing System Resource Management
* Solaris 10 Operating System
31
31
31
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Cluster Solutions
• 支持到 8 个节点
• Solaris 内核集成
Cluster功能
• 全局化 cluster
文件系统服务
• 全局化 cluster
设备服务
• 可扩展的全局化的网络
服务
Global
File System
Global Devices
High Speed
System
Interconnect
LAN/WAN
Scalable
Networking
Solaris
Domains
Scalable Services
Sun Cluster 3.1
Domain
A
Domain
B
Domain
C
Domain
D
Domain
E
32
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun 产品概述
Ultra SPARC IV
www.sun.com/servers
33
33
33
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
UltraSPARC IV processor in 2004
34
34
34
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
UltraSPARC Processor Roadmap
35
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun 产品概述
SUN 磁盘阵列
www.sun.com/servers
36
36
36
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 磁盘阵列家族
Sun StorEdge
9000 Family
Sun StorEdge
6000 Series
Sun StorEdge
3000 Family
Mission-Critical
Availability
Consolidation:
Mission-critical availability
for large consolidations
Essential
Value
Scalability
Performance:
Managed performance/
availability for
SAN environments
Operational
Flexibility
Simplicity:
Dense, reliable storage
for entry-level deployment
Data
Classification
ranked from
lowest
capital and
administrative
costs
Enables enterprise
virtualization and
provisioning, lowering
TCO
Heterogeneit
y
N1TM Data Services Platform
37
37
37
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge 3310 SCSI Array
SCSI Ultra3/Ultra 160
● 2 Rack Unit High, up to 12 Drives
RAID
● Single, Dual, or Mirrored RAID
Controllers
● 512MB cache per controller
● 2 host ports per controller
● Seamless RAID controller failover
● Up to 128 LUNs per array
Expansion
● Up to 2 JBOD expansion units
● Up to 36 drives per system
Management
● GUI, Web, Terminal Menu Interface
● In and/Out of Band
Industry Certifications
● NEBS Level 3 Certified
● MIL STD 810F Compliant for Land,
Air, Marine deployment
38
38
38
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge 3120
Dual redundant
hot swappable AC or
DC power supplies
Up to four
36 GB, 73 GB, or 146 GB
1-inch high disks
GUI management
interface
Single or dual
SCSI bus
Ultra320 SCSI LVD
to host and
disk drives
1U height (supporting
up to 584 GB)
Single or dual
host support
Up to 10m SCSI
cable support
A High-Capacity, High-Performance, Versatile, Easy-to-
Manage Array
39
39
39
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge 3510 FC Array
2Gb Fibre Channel
● 2 rack unit high, up to 12 hot swap, 2Gb fibre channel disk
drives
RAID
● Single or dual mirrored RAID controllers
● 1GB cache per controller
● Up to 8 direct connect host ports per array
● Seamless array based RAID controller failover
● Up to 1024 LUNs per array
Expansion
● Up to 8 JBOD expansion units
● Up to 96 drives per system with expansion units, Up to 16TB
Management
● GUI, Web, Terminal Menu, CLI interface
● In and/Out of Band
Industry Certifications
● NEBS Level 3 Certified
● MIL STD 810F Compliant for Land, Air, Marine deployment
FC Expansion Trays
40
40
40
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge 3511 FC Array SATA Balanced
Availability, High Scalability
• Dual redundant
2Gb Fibre Channel RAID
controllers
• 1GB cache/controller
• Dual hot-swap power supplies,
fans, and controllers
• Hot-swappable SATA drives
• 12 FC host ports, 12 server
configuration without switches
• Up to 16TB in a single
subsystem with 5 expansion
units
SATA Expansion Trays
41
41
41
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge™ 6120 Array
●2Gb Fibre Channel Fabric Array
●RAID array , up to 14 HDDs in 3RU high
●H/A configuration, up to 28 HDDs in 6RU high
Configuration Flexibility
●Single or dual RAID controller configurations
●1GB or 2GB cache; 1 or 2 ports per array
●64 volumes (LUNs) per array
●Mix and match
– RAID 0, 1(1+0), 5
– 36GB/15k; 73GB/10k; 146GB/10k HDDs
●Up to 4 expansion units per array
●7- 84 drives, 504GB – 12.2TB per array
Comprehensive Software
●CIM compliant array configuration and health mgmt
●Pre-set Storage Policies
●Volume masking and mapping
●CIM-compliant SAN-wide management
●Solaris fabric multi-path failover and load balancing
●Solaris-based, storage-independent Data Services
– Point-in-time copy
– Remote replication
Sun StorEdge™ 6120 Array
(maximum configuration)
42
42
42
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge 6320 System
Ethernet Hub Ethernet Hub
SAN模块
系统访问面板
FC网络
管理网络
存储模块
管理模块
SSRR 访问
模块化伸缩性和可用性
— 2-22 个 RAID控制器
— 2-22 2Gb fabric 端口
— 可混插并实现
–RAID 0, 1(1+0), 5
–36GB/15k,73GB/10k,&
146GB/10k HDDs
–控制器/扩展柜
– 14 – 308 个硬盘;504GB – 45TB
– 可选光纤Switch
– 集成的管理处理器和远程监控
配置软件
— CIM 兼容的阵列配置和健康管理
— 预先设置的存储策略
— Volume masking and mapping
— CIM 兼容的SAM管理
— Solaris fabric 多路径切换和负载
均衡
— CIM:Common Information Model 标准
化接口管理存储设备 SSRR-Sun StorEdge Remote Response
43
43
43
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge™ 6920
Ethernet Hub
N1
Data Service
Platform
FC Network
Mgmt. Network
Management
Module
SSRR Access
Storage
Module
System Controller
Data Services
Management
Connectivity Module
Ethernet Hub Ethernet Hub
MENU
44
44
44
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge™ 6130
• Fully redundant compact design
– Dual controllers in 3RU form factor
– 2GB of battery-backed cache
– Redundant, switched drive connectivity
● High scalable, from 5 to 112 drives
– 14 drives/storage module
– Up to 8 storage modules/system
● Multiple storage classes (FC/SATA)
– FC (10K, 73GB, 146GB)
– FC (15K, 73GB)
– SATA (7K, 400GB*)
● Dynamically tune volume settings
– Multiple RAID levels (0, 1, 1+0, 3, 5)
– Multiple and various VDISK sizes – up to 30 drives
● RAID 1 and 1+0, 1+1 up to 15+15
● RAID 3 and 5, 2+1 up to 29+1
– One or more volumes per VDISK
– Relocate VDISKs with complete data and RAID set
retention
* available within 30 days of release
45
45
45
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge™ 6130
SE6130 – FRONT VIEW SE6130 – BACK VIEW
Redundant power supplies and fans
help ensure system environmentals
Many (4x) 2Gb FC host ports,
ideal for redundant SAN deployments
Redundant (switched) disk drive
connectivity improves availability
Redundant RAID controllers mirror
IO's for high availability
Redundant power supplies ensure
against data loss if power fails
• Easily see overall system health and
status of critical hot-swappable FRUs
• 3RU form factor supports up to 5.6TB of
storage capacity (SATA) in a single storage
module
• Key configuration information is secured on
every system disk, eliminating system “panic”
should a drive fail
46
46
46
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 磁带库产品家族
Sun StorEdge
L25, L100, L180
Capacity,
Performanc
e, Retention
& Restore
Time
Sun StorEdge
L700, L5500/6000
Sun StorEdge stand
alone drives, L8
Workgroup Backup
Scalability, Flexibility
For mid-sized business
or departments
2.5TB to 34.8 TB
Local Backup
Small footprint
Entry level pricing for small
business or departments
20 GB to 1.6 TB
Consolidated Backup
Massively Scalable
Fabric SANs for the
enterprise 69TB to 1.1PB
47
47
47
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun StorEdge L8 Tape Autoloader
•磁带技术
•LTO、SDLT
•接口
•LVD Ultra 160 SCSI HD68
•非压缩容量
•800 GB LTO Gen 1
•1.6 TB LTO Gen 2
•1.3 TB SDLT
•传输速率
•15 MB/sec LTO Gen 1
•30 MB/sec LTO Gen 2
•16 MB/sec SDLT
•备份软件(bundle or no)
•Sun StorEdge Enterprise Backup o
• VERITAS NetBackup BusinesServer software
•Bar code reader(可选)
•Rackmount kit (可选)
•主机HBA: X6758A(PCI)
48
48
48
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
The Sun StorEdge L25 Module
Two removable magazines (10-cartridge slots with DLTtape &
12-cartridge slots for LTO Ultrium)
Available in LVD or HVD base modules
Only 4U (7-inches) high
Low cost/GB
One fixed cartridge location
Remote management, barcode reader and redundant power
supplies standard
LTO Gen1 & 2, DLT8000, SDLT 220 or SDLT 320 drives and media
60MB/sec native performance (with LTO 2)
Up to 2 drives x 21 DLTtape or 25 LTO cartridges
5TB native capacity (with LTO 2)
 Scalable up to 7 modules in a Sun
StorEdge rack (or three L25s and 1
L100)
 Robust, tri-axial robotics: small,
simple, reliable
 Super-quiet operations – virtually silent
 Every L25 module is StackLink ready
for scalability when you need it
 Configurable priority access load port
allows for access to cartridges while
module is operational
49
49
49
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
The Sun StorEdge L100 Module
Under 24-in (13.5U) high per module
Available in LVD or HVD base modules
Eight removable magazines each
with 10 DLTtape or 12 LTO Ultrium cartridges
Four fixed data and/or cleaning cartridge slots
Priority access load port allows for access to cartridges while
module is operational
LTO Gen1 & 2, DLT8000, SDLT 220 or SDLT 320 drives and media
180MB/sec native performance (with LTO Gen. 2)
1-5 drives x 84 DLTtape or 100 LTO cartridges
6 drives x 73 DLTtape or 87 LTO cartridges
20TB native capacity (with LTO Gen. 2)
●Scalable up to 7 modules in a Sun StorEdge
rack (or three L25s and 1 L100)
●Robust, tri-axial robotics: small,
simple, reliable
●Super-quiet operations – virtually silent
●Every L25 module is StackLink ready
for scalability when you need it
●Configurable priority access load port
allows for access to cartridges while module
is operational
50
50
50
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
The Sun StorEdge L180
磁带机技术 SDLT、LTO或9940B,且支持混装
盒式磁带插槽的数量 83、174
磁带驱动器的数量 多达10台DLT8000/LTO、或6个
9940B驱动器
磁带库容量(满配174 磁带) 未压缩容量
LTO 1(每盒磁带100GB) 17.4TB
LTO 2(每盒磁带200GB) 34.8TB
SDLT320(每盒磁带160GB) 27.8TB
9940B(每盒磁带200GB) 34.8TB
磁带库数据持续传送速率 未压缩容量
LTO(10个驱动器) 150MB/秒
LTO(10个驱动器) 300MB/秒
SDLT320(10个驱动器) 160MB/秒
9940B(6个驱动器) 180MB/秒
接口类型 差份SCSI/SCSI-3/FC
51
51
51
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
The Sun StorEdge L700
磁带机技术 SDLT、LTO或9940B,且支持混装
盒式磁带插槽的数量 228、396、678
磁带驱动器的数量 多达20台DLT8000/LTO、或12个
9940B驱动器
磁带库容量(满配174 磁带) 未压缩容量
LTO 1(每盒磁带100GB) 67.8TB
LTO 2(每盒磁带200GB) 135.6TB
SDLT320(每盒磁带160GB) 108.5TB
9940B(每盒磁带200GB) 135.6TB
磁带库数据持续传送速率 未压缩容量
LTO(20个驱动器) 300MB/秒
LTO(20个驱动器) 600MB/秒
SDLT320(20个驱动器) 320MB/秒
9940B(12个驱动器) 360MB/秒
接口类型 差份SCSI/SCSI-3/FC
52
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
SUN产品和其他品牌的比较分析
www.sun.com/servers
53
53
53
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
SUN产品和其他品牌的比较分析
• 市场占有率
• 操作系统
• 可靠性
• 投资保护
• 性能
• 发展展望
54
54
54
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun #1 UNIX Platform Server Shipment
Market Share
Source: IDC's Worldwide Quarterly Server Tracker, February 2004
55
55
55
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
许多在各行业居于领先的公司和企业都选择了Sun的产品
•  Fortune 500中前5名电信大企业中有4家采用Sun的服务器
•  Fortune 500中前5名航空航天大企业中的4家采用Sun的服务器
•  Fortune 500中的5家娱乐业公司中的4家基于Sun的服务器
•  Fortune 100中7家银行中的5家采用Sun的服务器
•  Fortune 1000中所有软件公司中的四分之三采用Sun的服务器
•  80%的因特网应用运行于Sun的系统
•  75%的ISP服务器基于Sun的平台
56
56
56
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
D.H. Brown on RAS
2001 Unix Function Review
(OSs @1/01)
AIX Update
(AIX @ 5/01 & Est. Fall 2001)
Still way behind!
57
57
57
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Solaris™ Operating Environment – Compellingly Ahead
58
58
58
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
RAS Strategies
IBM pSeries
Sun Fire
High
Reliability
Online
Maintenance
Sun vs IBM Availability
Minimizes planned
and unplanned
downtime
Sun Fire servers:
●Highly reliable servers with
online maintenance
IBM pSeries servers:
●Highly reliable servers that
require deferred
maintenance
●IBM pSeries lack features
needed to minimize planned
downtime
59
59
59
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
完全的硬件冗余备份
电源
电源线
冷却
I/O 卡
I/O 组件
CPU/Memory 板
系统控制器
交互连结
自动故障切换系统时钟
Sun IBM HP
60
60
60
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
在线可服务性 Comparison
Features Sun Fire 4800-15K IBM p670/p690
Hot Swap CPUs Yes No
Hot Swap Memory Yes No
Hot Swap I/O Yes PCI Cards Only
Hot Swap Service Processors Yes No
Hot Swap Power Supplies Yes Yes
Hot Swap Fans Yes Partial *
Serviceable Partitions Yes No
Isolated Hardware Diagnostics Yes No
Dynamically Resize Partitions Yes AIX 5.2 only
61
61
61
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
投资保护
CPU/Memory Uniboard
PCI Card
System Controller
I/O Assembly
Sun
Fireplane Board
Fans
Power Supply
Sun Fire
E20K
Sun Fire
E25K
Sun Fire
E4900
Sun Fire
E6900
Unique
Unique Unique
Unique
• 12,700 Solaris 应用
• 公用组件, 包括Sun Fire Midframe与
15K之间公用的 CPU/Memory 板
• 同样的 UltraSPARC 体系结构
• 通用系统
62
62
62
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire 4800/4900-15K/25K Servers Offer Lower Cost
System Upgrades
● Upgrade chassis
● Move key
● components
Sun Fire 12K
Sun Fire 6800
IBM p670
IBM p690
● Replace system
● Buy new CPUs
● Buy new memory
● Buy new boards
● Buy new ....
Sun Fire Upgrade IBM pSeries Upgrade
Leverage
your
investment
Expensive, box
swap upgrade
Uniboard
63
63
63
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
TPC-C Game
824164
763,898
514034.72
455818
433107
$8.31
$11.50
$28.58
$12.98
$8.28
0
100000
200000
300000
400000
500000
600000
700000
800000
900000
$0
$20
$40
$60
$80
$100
pSeries
690
32-way
DB2
tpmC $/tpmC
Fujitsu
PrimePower
128-way
SymfoWARE
Sun Fire
15K
72-way
tpmC
HP
Superdome
64-way
Oracle10G
NEC
Express
32-way
SQL Server
NEC
Express
32-way
SQL Server
64
64
64
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
OLTP Scaling on ad-hoc Database
65
65
65
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
IBM: Creative CPU Benchmarks
IBM's Method*
• Take 1 POWER4
core on
an 8 core module
• Use entire L2 cache
• Use all four L3 caches
on the multi-chip
module.
IBM's "Results"
1.3x better
SPEC2K #s
BUT:
>10x area
>10x transistors
>2.5x power
(assumes 7 cores & 3
L2 caches are off)
Power4 Benchmark Testbed
32MB
32MB
32MB
32MB
>1GHz
Core
Chip – Chip
Communication
>1GHz
Core
1.5MB L3
1.5MB
1.5MB
1.5MB
L3
Dir
66
66
66
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Use SpecRATE not SPEC to Evaluate Large
Server Performance
IBM 1.7GHz Power4+处理器 Sun SPARCIII 1.2GHz处理器
32 颗 36 - 48颗
比例关系: 1 : 1.1 – 1.5
system cpus GHz base peak base peak
SunFire 15K 64 1.2 539 645 390 436
SunFire 15K 48 1.2 414 492 300 336
SunFire 12K 36 1.2 315 379 230 260
SunFire 12K 32 1.2 281 338 206 232
SunFire 12K 28 1.2 254 305 186 208
SunFire 12K 16 1.2 174 145
IBM p690+ 32 1.7 358 372 322 339
IBM p690 32 1.3 251 260 232 249
IBM p690 16 1.3 179 187 144 149
HP Superdome64 64 0.875 267 288 394 413
SunFire6800 8 1.2 70.1 86.1 54.5 61.4
IBM P650-6M2 8 1.45 79.7 82.4 72.7 75.5
fp_rate int_rate
Source from Spec.org
67
67
67
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 发展展望
68
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
SUN产品的选型配置
www.sun.com/servers
69
69
69
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 产品配置
• 服务器配置
• 磁盘阵列配置
• 磁带库配置
70
70
70
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun 服务器选型配置
• 应用类型
• 配置性能及扩展性能
• 可靠性、可用性、可服务性
• 投资保护
• 硬件配置
71
71
71
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
服务器选型-应用类型考虑
72
72
72
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
最优化的系统设计
水平扩展
垂直扩展
I/O
● 连续的缓存, 共享内存 多处理器
● 单操作系统
● 紧密的内部互连
● 集群, 多处理器, 非共享内存
● 多操作系统
● 松散的外部互连
Memory
Switch
Network
Switch
VERTICAL
HORIZONTAL
CPU MEM I/O
CPU MEM I/O
CPUMEM I/O
CPU MEM I/O I/O
CPU MEM
CPUMEM I/O
CPU MEM I/O
CPUMEM I/O
CPU MEM I/O
CPU MEM I/O
CPU MEM I/O
CPU MEM I/O
I/O
CP
U
CP
U
MEMMEM I/O
I/O
CP
U
CP
U
MEMMEM I/O
CPU
CP
U
MEMMEM I/O
73
73
73
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
水平扩展-最优化系统负载
流媒体
J2EE应用服务 负载均衡
内容缓存
文件和打印
协作计算
Web 服务
目录和身份管理
安全
本地内容缓存
74
74
74
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Application Servers
Directory
Servers
Email Servers
垂直扩展系统的业务负载
OLTP Databases
DW/BI
CRM/SCM/ERP
75
75
75
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
服务器选型-系统性能考虑
Database
Tier
Appl-
ication
Tier
DSS
OLTP
Operational Storage
Web Web Web Web Web
Apps
Server
Apps
Server
Apps
Server
OLTP Database
Web
Tier
TPC-C
SPEC-
Jbb
ORCL Apps, SAP, PSoft,
Seibel, Amdoc, Retek...
TPC-W
TPC-H,
TPC-R,
Query
Tests
APB1,
Holos
Warehouse Storage
Web Web Web Web Web
OLAP
Data
Mart
Data
Mine
DSS Database
Neovista,
Darwin
SPEC-
Web
76
76
76
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Benchmark真相 Real World vs. Benchmarks
Benchmark
Specials
(Optimizations)
Hard
Easy
Complexity
Simple Complex
Real
World
Workloads
TPC-D(1999)
SPECrate
TPC-D(1997)
TPC-C(now)
TPC-C(1995)
IO Tests
Net Tests
TPC-H
Oracle Apps
Peoplesoft
SAP
SPECjbb
Amdocs
(1999)
Stream BW
Volano
Benchmark测试意义:
• 系统规模配置依据(sizing)。
• 市场宣传(Marketing)。
77
77
77
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
影响系统性能的关键因素
• 处理器 Processor
性能 Performance
吞吐能力 Throughput
• 系统内部互连 System Interconnect
延迟 Latency
访问内存数据块所需的时间
内部带宽 Internal bandwidth
I/O, Memory与 CPU间的数据传送
• 操作系统 Operating System
可扩展性 Scalability
可靠性 Reliability
• 应用优化 Optimized applications
78
78
78
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
服务器选型-可靠性、可用性、可服务性(RAS)
• 设备本身的RAS
完全冗余部件
热交换部件
动态重配置
系统自动恢复
系统故障自动跟踪
动态系统域
• 系统架构
负载均衡
替换双通道
HA/Cluster
79
79
79
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
服务器选型- 投资保护
• 通用部件
• 二进制兼容性
80
80
80
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
服务器硬件配置
• 参考Sun 配置指南
• 配置实例(见后面)
81
81
81
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
磁盘阵列选型配置
• 配置性能、容量
• 可靠性、可用性、可服务性
• 硬件配置
82
82
82
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
性能、容量
• 性能指标, 如:IOPS
• 数据量要求。
• RAID方式
• 数据扩展要求
83
83
83
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
磁盘阵列选型 -可靠性、可用性、可服务性
• 冗余部件
控制器
冗余通道
RAID方式
• 热交换部件
• 磁盘阵列冗余配置
84
84
84
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
磁盘阵列硬件配置
• 参考Sun 配置指南
• 配置实例(见后面)
85
85
85
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
磁带库选型配置
• 配置性能、容量
• 可靠性、可用性、可服务性
• 备份软件
• 硬件配置
86
86
86
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
磁带库选型 -配置性能、容量
• 备份窗口(时间)- 选择磁带机类型和数量
备份窗口=数据量/备份速度*备份效率
备份速度=数据量/备份窗口*备份效率
• 备份容量 - 选择磁带库容量和磁带数量
备份策略
3-5倍的数据量
• 备份效率:70%
87
87
87
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
磁带库选型 -备份软件
• 备份软件选择
Sun 备份软件
Sun OEM Veritas 备份软件
• 软件配置
软件介质
Server license
Client license
Application license
Tape driver license
SAN (Media server license、磁带机共享license等)
88
88
88
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
磁带库硬件配置
• 参考Sun 配置指南
• 配置实例(见后面)
89
89
89
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
配置实例
SE3510
磁盘阵列
以太网
数据库
服务器
V480
数据库
服务器
V480
心跳线
Sun L25
磁盘库
备份服务器
V240
数据库服务器HA
90
90
90
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
配置实例 – 配置V480服务器
2
A37-WBPF2-04GRB
Sun Fire V480 Server, 2 * 1.2GHz UltraSPARC III Cu
processors with 8MB Ecache each, 4GB memory (16 *
256MB DIMMs), 2 * 73GB 10K rpm FC-AL hard disks,
DVD-ROM, 2 * 10/100/1000 ethernet ports, 1 * serial port,
2 * USB ports, 6 * PCI slots, 2 (N+1 redundant)
1
SG-XPCI1FC-QF2 2Gb PCI Single FC Ntwk Adapter 光纤通道卡 2
X3151A Sun Gigaswift Ethernet MMF 2
X3770A Sun(tm) XVR-100 GraphicS 1
X312E CHINESE PWR CRD 电源线 2
X7147A 17" Flat Dispay CRT Monitor 1
X3582A
International Type 6 Country Kits Chinese with USB
interface 键盘书鼠标
1
数据库服务器 V480,2台, 每台配置2x1.2GHz CPU, 4GB RAM, 2x73GB HDD,
2x2GB FC HBA,2口1000Mbps MMF网卡, 2x100/1000Mbps UTP网卡
91
91
91
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
配置实例 – 配置SE3510磁盘阵列
XTA3510R01A2R365
Sun StorEdge 3510 Fibre Channel Array, Rack Ready,
365-GB (5 x 73-Gbyte 10K RPM disks) w/2 FC-AL HW
RAID controllers, 1GB std cache per controller, 2 AC power
supplies, 6 SFP's, and Sun StorEdge Configuration
Service.
1
XTA-3510-73GB-10K 73GB Fibre Channel, 10Krpm drive 1
X312E CHINESE PWR CRD 电源线 2
X9734A 15M LC to LC FC Optical Cable 光纤 4
XTA-3000-2URK-19U SE3000 2U Univ Rk Rail Kit 上架安装套件 1
NMK9S-00B-99Y9 StorEdge MGMT SW Kit 管理软件 1
92
92
92
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
配置实例 – Sun Cluster配置
CLUZS-999-99M9 the latest update release of Sun Cluster 3.1 media kit, 1
CLA9S-999-99M9
the latest update release of Sun Cluster 3.1 Agent media
kit, 1
CLSIS-LCO-G999
SunPlex server license for Sun Fire V480. One license
required per server. 2
CLAIS-XXR-9999
SunPlex agent license HA Oracle agent. One license
required per cluster. 1
93
93
93
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
配置实例 – Sun V240备份服务器配置
N32-XWB2-9S-202AV2
Sun Fire V240, 2 x 1.28GHz UltraSPARC IIIi, 4 x 512MB
DIMMS, 2 x 36GB Drives, 4 x 10/100/1000 Gigabit
Ethernet, ALOM Remote Manager, Three PCI Slots, n+1
Redundant Power.
1
X7410A X-Option DVD-ROM 1
X6758A PCI dual channel Ultra3 SCSI host bus adapter 1
X3770A Sun(tm) XVR-100 GraphicS 1
X312E CHINESE PWR CRD 电源线 2
X7147A 17" Flat Dispay CRT Monitor 1
X3582A
International Type 6 Country Kits Chinese with USB
interface 键盘鼠标
1
94
94
94
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
配置实例 – Sun L25磁带库配置
1
SG-XLIBL25LLV-BASE L25 LTO LVD Base 1
SG-XMEDLTO200GB-10 LTO Gen 2 Media, 200GB, 10pack 1
SG-XMEDLTOUNVCL-10 LTO Univ. Cleaning Cart. 10 PK 1
SG-XTAPLTO2LVD-MOD LTO Gen 2 LVD SCSI - L25/L100 2
X312E CHINESE PWR CRD 1
X3830A 4M CABLE, SCSI 68 TO VHDCI68 1
SG-XMGMTCARDL-MOD Mgmt. Card-for LVD L25/100 1
Sun L25 2xLTO2driver
95
95
95
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
配置实例 – Sun 备份软件配置
1
VNESU-501-9999
VERITAS NetBackup 5.0/5.1 Server and
Enterprise Server Media Kit for UNIX and
Windows/NT Platforms 1
VNESU-999-W999
VERITAS NetBackup Enterprise Server
License on UNIX Platforms which include
Solaris, HP-UX, AIX, and Tru64 for Desktop and
Workgroup Server Class 1
VOCPL-999-9999
VERITAS NetBackup Option Cross Platform
Library Based Tape Drive Support License 2
VCPSS-999-9999 VNBU Protect Client-UNIX Svr 2
VDSOU-999-W999 VNBU DB Agent - Orcl/UNIX-Wkp. 2
Veritas NetBackup Enterprise Server 5.1
96
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Option
www.sun.com/servers
97
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
SUN工作站详细介绍
www.sun.com/servers
98
98
98
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Blade 150 工作站
• 64-bit 650-MHz UltraSPARC IIi 处理器, 512KB of Level 2 缓存
• 4 GB DRAM 内存 (4 x 1GB Dimms)
• 2x 80GB 7200-RPM 硬盘
• DVDROM (标准), 48xCDRW (可选)
• 4x USB 端口,2x IEEE 1394 端口
• 3个全长32 bit/33MHz PCI I/O
• 支持1个 XVR-600 入门级 3D 图形卡
• 10/100BASE-T 以太网口
• Solaris 8 12/02 以后的操作系统
99
99
99
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
B150 系统视图
100
100
100
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Blade 1500 工作站
• 1个1.06 GHz UltraSPARC-IIIi CPU, 1MB L2 缓存
• 4 GB内存 (4x 1GB DDR266)
• 3.2 GB/s 总线带宽(200 MHz x 128-bit)
• 4.2 GB/sec 内存带宽
• 2个80 GB ATA-100 硬盘
• 2个 PCI 总线, 5 PCI 插槽
•2个 64-bit/33MHz, 2x 32-bit/33MHz 插槽
•1 专用总线, 1x 64-bit/66MHz PCI 图形卡插槽
• 支持2个 XVR-600 图形卡
• 4个USB1.1, 3x USB 2.0, 2x IEEE1394 口
• 10/100/1000 Base-T 网口(主板上)
• Solaris 8 HW 05/03, Solaris 9 U6 04/04
101
101
101
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
B1500 系统视图
102
102
102
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Blade 2500 工作站
• 2 个1.28GHz UltraSPARC-IIIi CPU, 1 MB L2 缓存
• 8GB DDR-266 ECC 内存
•每CPU 3.2 GB/sec有效系统带宽
• 8.4 GB/sec 内存带宽
• 支持2个高端 XVR-1200 双通道图形卡
• 高吞吐量
• 4个 PCI 总线, 6 PCI 插槽, 2 个专用的图形卡插槽
• 10/100/1000网口
• Solaris 8 HW 05/03, Solaris 9 U6 04/04
103
103
103
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
B2500 系统视图
104
104
104
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
• CPU数量: w1100z 1个,w2100z 2个
• CPU频率:1.8/2.0/2.2/2.4 GHz
• CPU L2:1MB
• CPU互连:每CPU 3个连接通道,每个通道6.4 GB/s
• 内存:每个CPU 4个DIMM槽,512MB/1GB/2GB DIMM, 成对安装
• 网络:1个10/100/1000Mbps RJ45
• 硬盘:2个 U320 SCSI 或ATA
• 光驱:DVD-ROM / CD-RW (标准) DVD + R/RW (可选)
• PCI-X 槽:5个 64-bit PCI-X slots
• 操作系统:Solaris 9 OS (x86),32- and 64-bit Linux,
Windows XP Professional
Sun w1100z/w2100z 工作站
105
105
105
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun w1100z/w2100z 系统视图
106
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
SUN 工作组(批量)服务器
详细介绍
www.sun.com/servers
107
107
107
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
工作组(批量)服务器
• Sun Fire V20z and V40z Servers (AMD 32/64bit)
• Sun Fire V60x and V65x Servers (Intel XEON)
• Sun Fire V210/V240/V250/V440 Server (Ultra SPARC
IIIi)
• Lights Out Management(LOM)
• Remote System Control (RSC)
• Sun Netra 20 (Ultra SPARC III)
• Sun Fire V480 and V880 (Ultra SPARC III)
• Sun Fire V490 and V890 (Ultra SPARC IV)
108
108
108
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V20z
• 2个1.6/1.8/2.2 GHz AMD Opteron处理器, 1MB L2 缓存, 1U 可上架
•64-bit / 32-bit 兼容
•CPU-to-CPU 、CPU-to-I/O 2个带宽3.2GB/s通道(6.4GB/s带宽)
•16GB DDR1/333 MHz ECC SDRAM 内存
•2 热交换 73GB 10000 转 Ultra320 SCSI 硬盘
• 2个 PCI-X 插槽(1 全长 64-bit/133MHz, 1 半长 64-bits/66MHz)
• 2个10/100/1000Mbps 以太网口t
• Solaris 9 x86 4/04, 32-bit
• Red Hat Enterprise LInux 3.0, 32/64-bit
109
109
109
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V20z 系统视图
110
110
110
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V40z
• CPU: 4个 2.4 GHz AMD Opteron 处理器, 1MB L2 缓存
• 带宽: CPU-to-CPU 、CPU-to-I/O links deliver 2x3.2GB/s,(6.4GB/s
aggregate) 每个连接
•内存: 32GB DDR1/333 MHz ECC SDRAM
• 硬盘:5 个热交换 146GB 10K rpm Ultra320 SCSI
• PCI-X插槽:7个PCI-X
• 网络: 2个10/100/1000Mpbs RJ45
• 操作系统:Solaris 9 x86 4/04, 32-bit, Red Hat Enterprise LInux 3.0,
32/64-bit
111
111
111
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V40z 系统视图
112
112
112
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V60x and V65x Servers
113
113
113
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V60x Server
114
114
114
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
115
115
115
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V65x Server
116
116
116
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
117
117
117
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V100/V120
 550 or 650-MHz
UltraSPARCIIi, 512 KB L2
Cache
 2 GB Maximum Memory: 4 Slots,
128, 256, or
512 MB PC 133 DRAM DIMMs
 80 GB Disk Capacity: 2x 40 GB
7200 RPM IDE Disk Drives
 Pre-installed Internal CD-ROM
 2 x 10/100BaseT Ethernet
Ports, 2 USB Ports IDE
disk controller, 2 serial ports
 550 or 650-MHz UltraSPARC-IIi,
512 KB L2 cache
 4 GB Maximum Memory: 4 slots
 256, 512 MB,
or 1 GB PC 133 DRAM DIMMs
 72 GB Disk Capacity: 2x 36 GB
10,000 rpm hot-swappable
UltraSCSI disk drives
 Optional CD-ROM or DVD-ROM
 Full-length PCI slot
 Solaris 8 Operating Environment
and LOM preloaded
118
118
118
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Netra 120 Server
 650-MHz UltraSPARC-IIi, 512 KB L2 cache
 4 GB Maximum Memory: 4 slots  256, 512 MB,
or 1 GB PC 133 DRAM DIMMs
 72 GB Max Disk Capacity: Up to two 36 GB
10,000 rpm hot-swappable UltraSCSI disk drives
 Optional CD-ROM or DVD-ROM
 Solaris 8 Operating Environment and LOM preloaded
 NEBS Level 3 certified
 DC Power Supply
119
119
119
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V120 and Netra 120 背板
 2 10/100BaseT
 1 UltraSCSI port
 PCI card back panel
 2 异步串口
 ALOM
 1 USBs
120
120
120
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V240
Sun Netra 240
Sun Fire V210
Server
高密度服务器解
决方案
高性能
企业级RAS特性
低功耗
Sun Fire V210 /V240
New US-IIIi Systems
121
121
121
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V210 Server
122
122
122
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
123
123
123
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V240 Server
124
124
124
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
125
125
125
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V250 System
126
126
126
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V250 System Overview
● 1-2 UltraSPARC(TM)
IIIi 处理器
● 1.06GHz or 1.280GHz with 1MB On-Chip L2-cache
● On-Chip 64KB data and 32KB instruction cache
● 8GB 内存 (16GB when 2GB DIMMs qualified), 8 DIMM slots
● J-Bus 系统总线时钟 160MHz, 峰值带宽 2.56 GB/sec
● 8个热交换 Ultra160SCSI 36GB or 73GB 10Krpm 硬盘
● 6个64-bit PCI slots, 3 x 33/66 MHz, 3 x 33 Mhz
● Sun Advanced Lights Out Manager (ALOM)
● 系统配置卡System Configuration Card (SCC)
● 外部端口 : 1 x10/100/1000Base-T, 2 个串口, 1 个并口, 1 Ultra160 SCSI, 4 USB,
管理以太网10Mbps端口
● DVD-ROM, 可选内置 DDS-4 DAT 磁带机
● 1+1 冗余电源
127
127
127
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V440
(1) Configuration pricing based on 2P/4GB/4 disk, competitor pricing
as of 9/15/03
128
128
128
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
129
129
129
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V480 Server
130
130
130
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
131
131
131
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
CPU/Memory Module
132
132
132
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V880 Server
133
133
133
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
134
134
134
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
System View
135
135
135
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
CPU/MEM Boards
136
136
136
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
I/O Subsystem
137
137
137
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Internal FC-AL Disk Subsystem
138
138
138
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
RAS Features
• 热插拔硬盘、PCI槽热交换电源风扇。
• 容易访问内部可替换部件。
• 4级系统诊断
• 可替换通道硬盘、网络
• 独立的远程系统控制模块
• 自动系统恢复
139
139
139
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Automatic System Recovery(ASR)自动系统恢复
• 提供硬件部件失败的自动系统恢复
-CPUs, Memory modules
-PCI buses and cards, SCSI bus, FC-AL subsystem
- Ethernet interface
- USB interface, Serial interfaces
• 允许非致命硬件遭受错误和失败后系统重新运行
-自动检测并隔离失效部件
-自动系统重配置能力
-ASR能使系统自动重起动,恢复运行,不需要人为干预
140
© 2004.Teamsun. All rights reserved.
Session Number
Presentation_ID
http://www.teamsun.com.cn
Sun Fire V490 & V890 服务器
新产品
www.sun.com/servers
141
141
141
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Sun Fire V490 & V890 Servers
CMT UltraSPARC IV now
available in sub $50k platforms
Up to x2 throughput of previous
generation with only 10%-30%
higher cost delivering improved
price / performance
Sun Fire
V100/V120
Sun Fire
V210/V240
Sun Fire
V250
Sun Fire
V440
Sun Fire
V480
Sun Fire
V880
Sun Fire V890
Sun Fire V490
142
142
142
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
● Up to 4 UltraSPARC IV 1.05
GHz, dual-threaded
processors
● Rack Optimised 5RU
package
● Up to 32GB memory, 2 FC-
AL disk drives multipathing
ready
● 9.6 GB/sec. Sun Fireplane
Interconnect
● Six 64 bit PCI slots -- 4 @
33 MHz, 2 @ 66 MHz
● Dual 10/100/1000-Mbps
Ethernet ports
● N+1 Hot Swap Power
Supply / Hot Pluggable
Disks
Sun Fire V490 Server
Key Benefits
● Lowest cost platform to incorporate
Enterprise Class Sun technologies
● Up to x2 the throughput of the Sun Fire V480
Server – the world's top selling 4P platform in
2003
● 5RU enclosure maximises Data Center
performance and compute density
● Binary compatibility and support for JES
ensure faster service deployment & reduced
cost and complexity
● Integration with Containers delivers an
affordable Consolidation & Migration platform
● Extensive RAS & Remote Management for
HA requirements
● Ideal for demanding application and
infrastructure services
143
143
143
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
● Up to 8 UltraSPARC IV 1.2
GHz, dual-threaded
processors
● Up to 64GB memory, 12 FC-
AL disk drives multipathing
ready
● 9.6 GB/sec. Sun Fireplane
Interconnect
● Nine 64 bit PCI slots -- 7 @
33 MHz, 2 @ 66 MHz
● 1 Gb and 10/100 Ethernets,
two serial ports, two USB
ports
● Integrated FC-AL controller
● Remote Systems
Management Card; ALOM+
Hardware and RSC
Sun Fire V890 Servers
Key Benefits
● Up to x2 the throughput of the Sun Fire V880
Server – the world's top selling 8P platform in
2002 & 2003
● Binary compatibility and support for JES
ensure faster service deployment & reduced
cost and complexity
● Integrated, self-contained systems allows
efficient integration into IT infrastructure,
delivering faster ROI
● Integration with Containers delivers an
affordable Consolidation & Migration platform
● Powerful enough for demanding database &
application requirements
● Sub $50k price point provides compelling
price/performance story
144
144
144
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Highest Performance Platforms
See Legal Substantiation
slide
The Sun Fire V890 delivers the best SPECcpu_rate results in
its class demonstrating best performance for application and
database services at prices starting below $50k
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
S un Fi
re V 890 S P E C i
nt
_rat
e2000 118
S P E C fp_rat
e2000 149
I
B M p650 S P E C i
nt
_rat
e2000 75
S P E C fp_rat
e2000 84
I
B M p550 S P E C i
nt
_rat
e2000 65
S P E C fp_rat
e2000 84
I
B M x445 S P E C i
nt
_rat
e2000 75
N o S P E C fp_rat
e2000 R esul
t
s P ubl
i
shed
H P rp4440-8 S P E C i
nt
_rat
e2000 73
See Legal Substantiation
slide
All products quoted above have starting prices below $50k
Actual configurations used to obtain the above benchmark results vary from $59.2k to $200k+
Sun Fire V890 was configured with 8 Processors / 32GB Memory and has a list price of $123,995
145
145
145
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Customers Recommend
Sun Fire V490 & V890 Servers
Alain Barlier, Senior Architect OAM
Solution
Nortel Networks
“The Sun Fire V890 Server gave us 1 and a half times
the throughput over the Sun Fire V880 Server.
We found it not only improves the overall performance of
our application, but it also maximizes the uptime and
reliability, which is critical for our service level
agreements.”
146
146
146
© 2004. Teamsun. All rights reserved.
Presentation_ID
teamsun.com.cn
Customers Recommend
Sun Fire V490 & V890 Servers
Eric Mottier,
Product Manager, OMC Mobile Network
Management
Alcatel
“Alcatel is using Sun Fire V880 Server to host the
Alcatel's OMC Mobile Network management.
We have successfully tested the UltraSPARCIV Sun Fire
V890 Server and we are planning to use the Sun Fire
V890 or V490 server for the next releases to optimize our
ratio cost/performance.”

Mais conteúdo relacionado

Semelhante a Sun全线硬件产品.ppt

Is OpenStack Neutron production ready for large scale deployments?
Is OpenStack Neutron production ready for large scale deployments?Is OpenStack Neutron production ready for large scale deployments?
Is OpenStack Neutron production ready for large scale deployments?Елена Ежова
 
Isc group llc gral presentation final revised 050212
Isc group llc gral   presentation final revised  050212Isc group llc gral   presentation final revised  050212
Isc group llc gral presentation final revised 050212Joelchait
 
Qnap Turbo Nas Business Series Presentation 2011
Qnap Turbo Nas Business Series Presentation 2011Qnap Turbo Nas Business Series Presentation 2011
Qnap Turbo Nas Business Series Presentation 2011Ali Shoaee
 
Sparc SuperCluster
Sparc SuperClusterSparc SuperCluster
Sparc SuperClusterFran Navarro
 
JetStor portfolio update final_2020-2021
JetStor portfolio update final_2020-2021JetStor portfolio update final_2020-2021
JetStor portfolio update final_2020-2021Gene Leyzarovich
 
Sparc的未来发展方向
Sparc的未来发展方向Sparc的未来发展方向
Sparc的未来发展方向legendnet368
 
Red Hat Storage Day Boston - Supermicro Super Storage
Red Hat Storage Day Boston - Supermicro Super StorageRed Hat Storage Day Boston - Supermicro Super Storage
Red Hat Storage Day Boston - Supermicro Super StorageRed_Hat_Storage
 
Cisco connect montreal 2018 compute v final
Cisco connect montreal 2018   compute v finalCisco connect montreal 2018   compute v final
Cisco connect montreal 2018 compute v finalCisco Canada
 
Evento Startup Essential Barcelona
Evento Startup Essential BarcelonaEvento Startup Essential Barcelona
Evento Startup Essential BarcelonaManuel Jaffrin
 
MX – универсальная сервисная платформа. Вчера, сегодня, завтра.
MX – универсальная сервисная платформа. Вчера, сегодня, завтра.MX – универсальная сервисная платформа. Вчера, сегодня, завтра.
MX – универсальная сервисная платформа. Вчера, сегодня, завтра.SkillFactory
 
PLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i Widoczność
PLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i WidocznośćPLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i Widoczność
PLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i WidocznośćPROIDEA
 
Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96波 董
 
Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96波 董
 
Emc vnx2 technical deep dive workshop
Emc vnx2 technical deep dive workshopEmc vnx2 technical deep dive workshop
Emc vnx2 technical deep dive workshopsolarisyougood
 
TechWiseTV Workshop: Application Hosting on Catalyst 9000 Series Switches
TechWiseTV Workshop: Application Hosting on Catalyst 9000 Series SwitchesTechWiseTV Workshop: Application Hosting on Catalyst 9000 Series Switches
TechWiseTV Workshop: Application Hosting on Catalyst 9000 Series SwitchesRobb Boyd
 
Abhishek Mallik Storage Administrator Lead
Abhishek Mallik Storage Administrator  LeadAbhishek Mallik Storage Administrator  Lead
Abhishek Mallik Storage Administrator LeadAbhishek Mallik
 
Technical Overview of Cisco Catalyst 9200 Series Switches
Technical Overview of Cisco Catalyst 9200 Series SwitchesTechnical Overview of Cisco Catalyst 9200 Series Switches
Technical Overview of Cisco Catalyst 9200 Series SwitchesRobb Boyd
 
Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000
Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000
Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000Cisco Russia
 

Semelhante a Sun全线硬件产品.ppt (20)

Is OpenStack Neutron production ready for large scale deployments?
Is OpenStack Neutron production ready for large scale deployments?Is OpenStack Neutron production ready for large scale deployments?
Is OpenStack Neutron production ready for large scale deployments?
 
Isc group llc gral presentation final revised 050212
Isc group llc gral   presentation final revised  050212Isc group llc gral   presentation final revised  050212
Isc group llc gral presentation final revised 050212
 
Qnap Turbo Nas Business Series Presentation 2011
Qnap Turbo Nas Business Series Presentation 2011Qnap Turbo Nas Business Series Presentation 2011
Qnap Turbo Nas Business Series Presentation 2011
 
Sparc SuperCluster
Sparc SuperClusterSparc SuperCluster
Sparc SuperCluster
 
Emc
EmcEmc
Emc
 
JetStor portfolio update final_2020-2021
JetStor portfolio update final_2020-2021JetStor portfolio update final_2020-2021
JetStor portfolio update final_2020-2021
 
Sparc的未来发展方向
Sparc的未来发展方向Sparc的未来发展方向
Sparc的未来发展方向
 
Red Hat Storage Day Boston - Supermicro Super Storage
Red Hat Storage Day Boston - Supermicro Super StorageRed Hat Storage Day Boston - Supermicro Super Storage
Red Hat Storage Day Boston - Supermicro Super Storage
 
Cisco connect montreal 2018 compute v final
Cisco connect montreal 2018   compute v finalCisco connect montreal 2018   compute v final
Cisco connect montreal 2018 compute v final
 
Evento Startup Essential Barcelona
Evento Startup Essential BarcelonaEvento Startup Essential Barcelona
Evento Startup Essential Barcelona
 
MX – универсальная сервисная платформа. Вчера, сегодня, завтра.
MX – универсальная сервисная платформа. Вчера, сегодня, завтра.MX – универсальная сервисная платформа. Вчера, сегодня, завтра.
MX – универсальная сервисная платформа. Вчера, сегодня, завтра.
 
PLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i Widoczność
PLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i WidocznośćPLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i Widoczność
PLNOG 17 - Alexis Dacquay - 100 G, Skalowalność i Widoczność
 
Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96
 
Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96Ubuntu core on bubblegum 96
Ubuntu core on bubblegum 96
 
Emc vnx2 technical deep dive workshop
Emc vnx2 technical deep dive workshopEmc vnx2 technical deep dive workshop
Emc vnx2 technical deep dive workshop
 
TechWiseTV Workshop: Application Hosting on Catalyst 9000 Series Switches
TechWiseTV Workshop: Application Hosting on Catalyst 9000 Series SwitchesTechWiseTV Workshop: Application Hosting on Catalyst 9000 Series Switches
TechWiseTV Workshop: Application Hosting on Catalyst 9000 Series Switches
 
Oracle super cluster m7
Oracle super cluster m7Oracle super cluster m7
Oracle super cluster m7
 
Abhishek Mallik Storage Administrator Lead
Abhishek Mallik Storage Administrator  LeadAbhishek Mallik Storage Administrator  Lead
Abhishek Mallik Storage Administrator Lead
 
Technical Overview of Cisco Catalyst 9200 Series Switches
Technical Overview of Cisco Catalyst 9200 Series SwitchesTechnical Overview of Cisco Catalyst 9200 Series Switches
Technical Overview of Cisco Catalyst 9200 Series Switches
 
Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000
Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000
Особенности архитектуры и траблшутинга маршрутизаторов серии ASR1000
 

Último

Growing Oxen: channel operators and retries
Growing Oxen: channel operators and retriesGrowing Oxen: channel operators and retries
Growing Oxen: channel operators and retriesSoftwareMill
 
Fields in Java and Kotlin and what to expect.pptx
Fields in Java and Kotlin and what to expect.pptxFields in Java and Kotlin and what to expect.pptx
Fields in Java and Kotlin and what to expect.pptxJoão Esperancinha
 
ERP For Electrical and Electronics manufecturing.pptx
ERP For Electrical and Electronics manufecturing.pptxERP For Electrical and Electronics manufecturing.pptx
ERP For Electrical and Electronics manufecturing.pptxAutus Cyber Tech
 
IA Generativa y Grafos de Neo4j: RAG time
IA Generativa y Grafos de Neo4j: RAG timeIA Generativa y Grafos de Neo4j: RAG time
IA Generativa y Grafos de Neo4j: RAG timeNeo4j
 
Your Vision, Our Expertise: TECUNIQUE's Tailored Software Teams
Your Vision, Our Expertise: TECUNIQUE's Tailored Software TeamsYour Vision, Our Expertise: TECUNIQUE's Tailored Software Teams
Your Vision, Our Expertise: TECUNIQUE's Tailored Software TeamsJaydeep Chhasatia
 
Cybersecurity Challenges with Generative AI - for Good and Bad
Cybersecurity Challenges with Generative AI - for Good and BadCybersecurity Challenges with Generative AI - for Good and Bad
Cybersecurity Challenges with Generative AI - for Good and BadIvo Andreev
 
Streamlining Your Application Builds with Cloud Native Buildpacks
Streamlining Your Application Builds  with Cloud Native BuildpacksStreamlining Your Application Builds  with Cloud Native Buildpacks
Streamlining Your Application Builds with Cloud Native BuildpacksVish Abrams
 
Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...
Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...
Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...OnePlan Solutions
 
How Does the Epitome of Spyware Differ from Other Malicious Software?
How Does the Epitome of Spyware Differ from Other Malicious Software?How Does the Epitome of Spyware Differ from Other Malicious Software?
How Does the Epitome of Spyware Differ from Other Malicious Software?AmeliaSmith90
 
OpenChain Webinar: Universal CVSS Calculator
OpenChain Webinar: Universal CVSS CalculatorOpenChain Webinar: Universal CVSS Calculator
OpenChain Webinar: Universal CVSS CalculatorShane Coughlan
 
20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.
20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.
20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.Sharon Liu
 
Deep Learning for Images with PyTorch - Datacamp
Deep Learning for Images with PyTorch - DatacampDeep Learning for Images with PyTorch - Datacamp
Deep Learning for Images with PyTorch - DatacampVICTOR MAESTRE RAMIREZ
 
Leveraging DxSherpa's Generative AI Services to Unlock Human-Machine Harmony
Leveraging DxSherpa's Generative AI Services to Unlock Human-Machine HarmonyLeveraging DxSherpa's Generative AI Services to Unlock Human-Machine Harmony
Leveraging DxSherpa's Generative AI Services to Unlock Human-Machine Harmonyelliciumsolutionspun
 
Top Software Development Trends in 2024
Top Software Development Trends in  2024Top Software Development Trends in  2024
Top Software Development Trends in 2024Mind IT Systems
 
eAuditor Audits & Inspections - conduct field inspections
eAuditor Audits & Inspections - conduct field inspectionseAuditor Audits & Inspections - conduct field inspections
eAuditor Audits & Inspections - conduct field inspectionsNirav Modi
 
Webinar_050417_LeClair12345666777889.ppt
Webinar_050417_LeClair12345666777889.pptWebinar_050417_LeClair12345666777889.ppt
Webinar_050417_LeClair12345666777889.pptkinjal48
 
Why Choose Brain Inventory For Ecommerce Development.pdf
Why Choose Brain Inventory For Ecommerce Development.pdfWhy Choose Brain Inventory For Ecommerce Development.pdf
Why Choose Brain Inventory For Ecommerce Development.pdfBrain Inventory
 
Watermarking in Source Code: Applications and Security Challenges
Watermarking in Source Code: Applications and Security ChallengesWatermarking in Source Code: Applications and Security Challenges
Watermarking in Source Code: Applications and Security ChallengesShyamsundar Das
 
Big Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/ML
Big Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/MLBig Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/ML
Big Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/MLAlluxio, Inc.
 

Último (20)

Growing Oxen: channel operators and retries
Growing Oxen: channel operators and retriesGrowing Oxen: channel operators and retries
Growing Oxen: channel operators and retries
 
Fields in Java and Kotlin and what to expect.pptx
Fields in Java and Kotlin and what to expect.pptxFields in Java and Kotlin and what to expect.pptx
Fields in Java and Kotlin and what to expect.pptx
 
ERP For Electrical and Electronics manufecturing.pptx
ERP For Electrical and Electronics manufecturing.pptxERP For Electrical and Electronics manufecturing.pptx
ERP For Electrical and Electronics manufecturing.pptx
 
IA Generativa y Grafos de Neo4j: RAG time
IA Generativa y Grafos de Neo4j: RAG timeIA Generativa y Grafos de Neo4j: RAG time
IA Generativa y Grafos de Neo4j: RAG time
 
Your Vision, Our Expertise: TECUNIQUE's Tailored Software Teams
Your Vision, Our Expertise: TECUNIQUE's Tailored Software TeamsYour Vision, Our Expertise: TECUNIQUE's Tailored Software Teams
Your Vision, Our Expertise: TECUNIQUE's Tailored Software Teams
 
Cybersecurity Challenges with Generative AI - for Good and Bad
Cybersecurity Challenges with Generative AI - for Good and BadCybersecurity Challenges with Generative AI - for Good and Bad
Cybersecurity Challenges with Generative AI - for Good and Bad
 
Streamlining Your Application Builds with Cloud Native Buildpacks
Streamlining Your Application Builds  with Cloud Native BuildpacksStreamlining Your Application Builds  with Cloud Native Buildpacks
Streamlining Your Application Builds with Cloud Native Buildpacks
 
Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...
Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...
Transforming PMO Success with AI - Discover OnePlan Strategic Portfolio Work ...
 
How Does the Epitome of Spyware Differ from Other Malicious Software?
How Does the Epitome of Spyware Differ from Other Malicious Software?How Does the Epitome of Spyware Differ from Other Malicious Software?
How Does the Epitome of Spyware Differ from Other Malicious Software?
 
OpenChain Webinar: Universal CVSS Calculator
OpenChain Webinar: Universal CVSS CalculatorOpenChain Webinar: Universal CVSS Calculator
OpenChain Webinar: Universal CVSS Calculator
 
20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.
20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.
20240319 Car Simulator Plan.pptx . Plan for a JavaScript Car Driving Simulator.
 
Deep Learning for Images with PyTorch - Datacamp
Deep Learning for Images with PyTorch - DatacampDeep Learning for Images with PyTorch - Datacamp
Deep Learning for Images with PyTorch - Datacamp
 
Leveraging DxSherpa's Generative AI Services to Unlock Human-Machine Harmony
Leveraging DxSherpa's Generative AI Services to Unlock Human-Machine HarmonyLeveraging DxSherpa's Generative AI Services to Unlock Human-Machine Harmony
Leveraging DxSherpa's Generative AI Services to Unlock Human-Machine Harmony
 
Top Software Development Trends in 2024
Top Software Development Trends in  2024Top Software Development Trends in  2024
Top Software Development Trends in 2024
 
eAuditor Audits & Inspections - conduct field inspections
eAuditor Audits & Inspections - conduct field inspectionseAuditor Audits & Inspections - conduct field inspections
eAuditor Audits & Inspections - conduct field inspections
 
Webinar_050417_LeClair12345666777889.ppt
Webinar_050417_LeClair12345666777889.pptWebinar_050417_LeClair12345666777889.ppt
Webinar_050417_LeClair12345666777889.ppt
 
Why Choose Brain Inventory For Ecommerce Development.pdf
Why Choose Brain Inventory For Ecommerce Development.pdfWhy Choose Brain Inventory For Ecommerce Development.pdf
Why Choose Brain Inventory For Ecommerce Development.pdf
 
Watermarking in Source Code: Applications and Security Challenges
Watermarking in Source Code: Applications and Security ChallengesWatermarking in Source Code: Applications and Security Challenges
Watermarking in Source Code: Applications and Security Challenges
 
Salesforce AI Associate Certification.pptx
Salesforce AI Associate Certification.pptxSalesforce AI Associate Certification.pptx
Salesforce AI Associate Certification.pptx
 
Big Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/ML
Big Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/MLBig Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/ML
Big Data Bellevue Meetup | Enhancing Python Data Loading in the Cloud for AI/ML
 

Sun全线硬件产品.ppt

  • 1. 1 1 1 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn
  • 2. 2 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn SUN产品介绍 北京华胜天成科技股份有限公司 2005年 www.sun.com/servers
  • 3. 3 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun 产品概述 SUN产品的分类(工作站、服务器、存储等产品) www.sun.com/servers
  • 4. 4 4 4 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire 工作站/服务器产品家族 SF E2900 SF V1280 SF E4900 SF 4800 SF E6900 SF 6800 SF E20K SF 15K SF 25K SF 15K Netra 120 Netra 240 Netra 20 Netra440 Netra 1280 SF V120 SF V210 SF V240 SF F280 SF V250 SF V440 SF V490 SF V480 SF V890 SF V880 Sun Ray Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 SF V20z/V40z SF V60x SF V65x SF Blade 1600 B100x&B200x 高端/中档 服务器 电信特性 服务器 入门级 服务器 瘦客户端工作站 服务器 X86 Linux 服务器 Sun W1100z /W2100z
  • 5. 5 5 5 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 磁盘阵列家族 Sun StorEdge 9000 Family Sun StorEdge 6000 Series Sun StorEdge 3000 Family Mission-Critical Availability Consolidation: Mission-critical availability for large consolidations Essential Value Scalability Performance: Managed performance/ availability for SAN environments Operational Flexibility Simplicity: Dense, reliable storage for entry-level deployment Data Classification ranked from lowest capital and administrative costs Enables enterprise virtualization and provisioning, lowering TCO Heterogeneit y N1TM Data Services Platform
  • 6. 6 6 6 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 磁带库产品家族 Sun StorEdge L25, L100, L180 Capacity, Performanc e, Retention & Restore Time Sun StorEdge L700, L5500/6000 Sun StorEdge stand alone drives, L8 Workgroup Backup Scalability, Flexibility For mid-sized business or departments 2.5TB to 34.8 TB Local Backup Small footprint Entry level pricing for small business or departments 20 GB to 1.6 TB Consolidated Backup Massively Scalable Fabric SANs for the enterprise 69TB to 1.1PB
  • 7. 7 7 7 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 光纤交换机家族
  • 8. 8 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun 产品概述 SUN 工作站 www.sun.com/servers
  • 9. 9 9 9 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 工作站
  • 10. 10 10 10 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire X86 and Linux 批量服务器
  • 11. 11 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun 产品概述 SUN 入门级服务器 www.sun.com/servers
  • 12. 12 12 12 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 批量服务器(一)
  • 13. 13 13 13 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 批量服务器(二)
  • 14. 14 14 14 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 中档、高端企业级和数据中心级服务器
  • 15. 15 15 15 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 新的UltraSPARC IV 多线程CMT企业级和数据 中心级服务器
  • 16. 16 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun 产品概述 SUN 电信特性服务器 www.sun.com/servers
  • 17. 17 17 17 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 电信特性(Netra)服务器
  • 18. 18 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun 产品概述 SUN 中高端服务器 www.sun.com/servers
  • 19. 19 19 19 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Ultra SPARC III Sun Fire 4800 Sun Fire V1280/Netra 1280 Sun Fire 6800 Sun Fire 12K Sun Fire 15K Sun Fire E2900 Sun Fire E4900 Sun Fire E6900 Sun Fire E20K Sun Fire E25K SUN 中高端服务器产品线 ● 12,700 Solaris 应用 ● 通用部件, 包括CPU/内存板 ● 统一的体系架构 ● 二进制兼容 NEW Ultra SPARC IV
  • 20. 20 20 20 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire 1280/4800/6800/12K/15K Server • Base on UltraSPARC III Cu • Support 1.2/1.35GHz UltraSPARC IV with UltraSPARC s400 Uniboard, Solaris 8 2/04, Solaris 9 4/04, SC firmware 5.16 or later, and hardwire upgrade kit
  • 21. 21 21 21 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 介绍 Sun Fire E2900, E4900, E6900, E20K, and E25K Servers • UltraSPARC IV Uniboards系统板 – 4个处理器,8个并发线程 – 32 GB 内存 • Sun Fire E20K /25K 服务器增强的I/O – 新扩展板 – 新热交换 hsPCI+ I/O 集合 – 提高60% I/O 性能
  • 22. 22 22 22 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire E20K and E25K Servers • 新的高带宽Sun Fireplane扩展板 • 新 hsPCI+ I/O 集合 • 增强的 I/O 性能 – hsPCI集合达到 60% 的吞吐量提高 • 增加66 MHz PCI slots数量 – hsPCI+ I/O 集合支持3x 33/66MHz slots, 1x 33 MHz – Sun Fire E25K支持 54x66 MHz 高吞吐量 I/O
  • 23. 23 23 23 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 完全二进制兼容服务器 Sun Fire E4900 ●Up to 12 UltraSPARC IV processors, 24 concurrent threads ●Up to 96GB RAM ●16 PCI slots ●1 or 2 Domains ●9.6 GB/s Sustained bandwidth ●Rack mount system (1 per rack) or deskside ●SRS Netconnect ●Solaris 8 and up Sun Fire E6900 ●Up to 24 UltraSPARC IV processors, 48 concurrent threads ●Up to 192GB RAM ●32 PCI slots ●1 to 4 Domains ●9.6 GB/s Sustained bandwidth ●Datacenter rack ●SRS Netconnect ●Solaris 8 and up Sun Fire E25K ●Up to 72 UltraSPARC IV processors, 144 concurrent threads ●Up to 576GB RAM ●72 hot swap PCI+ slots ●1 to 18 Domains ●172.8 GB/s Peak bandwidth (57 GB sustained) ●Datacenter rack ●SRS Netconnect ●Solaris 8 and up Sun Fire E20K ●Up to 36 UltraSPARC IV processors, 72 concurrent threads ●Up to 288 GB RAM ●36 hot swap PCI+ slots ●1 to 9 Domains ●86.4 GB/s Peak bandwidth (29 GB sustained) ●Datacenter rack ●SRS Netconnect ●Solaris 8 and up Sun Fire E2900 ●Up to 12 UltraSPARC IV processors, 24 concurrent threads ●Up to 96GB RAM ●6 PCI slots, 2 internal disks ●9.6 GB/s Sustained bandwidth ●Rugged, Compact ●Rack- Optimized ●SRS Netconnect ●Solaris 8 and up Solaris Operating System
  • 24. 24 24 24 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Common Components CPU/Memory Uniboard PCI Card System Controller I/O Assembly Sun Fireplane Board Fans Power Supply Sun Fire E20K Sun Fire E25K Sun Fire E4900 Sun Fire E6900 Unique Unique Unique Unique
  • 25. 25 25 25 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 空前的投资保护 • 完全的二进制兼容 – 支持 Solaris 8和 9 操作系统 • Board-level upgrades – UltraSPARC IV Uniboards run in Sun Fire V1280-15K servers* – UltraSPARC III Uniboards run in Sun Fire E2900-E25K servers – Mixed-speed CPU support (UltraSPARC III and IV Uniboards) – Mix and match Uniboards in same or separate domains – System level upgrades – Full factory-integration and testing *Other hardware and software upgrades required; V1280/E2900 use CPU/memory boards 不需要应用和操作系统迁移
  • 26. 26 26 26 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 全部硬件冗余 冗余的,热交换的部件 • N+1 redundant subsystems Failures don't affect operation Examples: System Controllers, system clock, power supplies, and fans • Redundant components Stable recovery from failures Examples: Uniboard CPU/memory boards, I/O assemblies, Sun Fireplane interconnect ASICS Automatic System Recovery (ASR) • Redundant I/O paths (both network and disk)
  • 27. 27 27 27 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 第五代动态系统域 • 域间错误隔离 • 域间资源动态重配置以适应应 用需求 • CPUs 、memory 重配置不依 赖 I/O
  • 28. 28 28 28 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 服务器虚拟化 A P P S A P P S A P P S A P P S A P P S A P P S A P P S Solaris 8 Solaris 9 Solaris 10 Domain 1 Domain 2 Domain 3 Server A P P S Containers A P P S 安全 错误隔离 提高资源利用 动态系统域 每一个层次: 硬件, 操作系统, 应用软件
  • 29. 29 29 29 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 第五代动态重配置 • 从一个运行的域中动态地增加和移去部件 – CPU/Memory 板, PCI 卡, 和整个 I/O 集合 – 操作系统和应用程序继续运行无需重启动 – 在线维护、在线CPU/内存等板卡升级,支持不同速率 的CPU混用 • WBEM-based Dynamic Reconfiguration (WDR)基于浏览器的动态重配 – 新的发展,工业标准的基于Web的企业系统管理 – 不同域之间资源的自动调整 – 预定的和可编程的资源调配方法
  • 30. 30 30 30 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Solaris Trusted Containers* • 虚拟的 OS service ,具有安全边界 • 容器(Containers)作为单独的Solaris 实例(Instance) • 应用隔离 • 提取系统的每个细节,进行客户化的容器 管理 • 没有专用的系统资源 – 任意粒度级管理 Optimizing System Resource Management * Solaris 10 Operating System
  • 31. 31 31 31 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Cluster Solutions • 支持到 8 个节点 • Solaris 内核集成 Cluster功能 • 全局化 cluster 文件系统服务 • 全局化 cluster 设备服务 • 可扩展的全局化的网络 服务 Global File System Global Devices High Speed System Interconnect LAN/WAN Scalable Networking Solaris Domains Scalable Services Sun Cluster 3.1 Domain A Domain B Domain C Domain D Domain E
  • 32. 32 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun 产品概述 Ultra SPARC IV www.sun.com/servers
  • 33. 33 33 33 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn UltraSPARC IV processor in 2004
  • 34. 34 34 34 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn UltraSPARC Processor Roadmap
  • 35. 35 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun 产品概述 SUN 磁盘阵列 www.sun.com/servers
  • 36. 36 36 36 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 磁盘阵列家族 Sun StorEdge 9000 Family Sun StorEdge 6000 Series Sun StorEdge 3000 Family Mission-Critical Availability Consolidation: Mission-critical availability for large consolidations Essential Value Scalability Performance: Managed performance/ availability for SAN environments Operational Flexibility Simplicity: Dense, reliable storage for entry-level deployment Data Classification ranked from lowest capital and administrative costs Enables enterprise virtualization and provisioning, lowering TCO Heterogeneit y N1TM Data Services Platform
  • 37. 37 37 37 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge 3310 SCSI Array SCSI Ultra3/Ultra 160 ● 2 Rack Unit High, up to 12 Drives RAID ● Single, Dual, or Mirrored RAID Controllers ● 512MB cache per controller ● 2 host ports per controller ● Seamless RAID controller failover ● Up to 128 LUNs per array Expansion ● Up to 2 JBOD expansion units ● Up to 36 drives per system Management ● GUI, Web, Terminal Menu Interface ● In and/Out of Band Industry Certifications ● NEBS Level 3 Certified ● MIL STD 810F Compliant for Land, Air, Marine deployment
  • 38. 38 38 38 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge 3120 Dual redundant hot swappable AC or DC power supplies Up to four 36 GB, 73 GB, or 146 GB 1-inch high disks GUI management interface Single or dual SCSI bus Ultra320 SCSI LVD to host and disk drives 1U height (supporting up to 584 GB) Single or dual host support Up to 10m SCSI cable support A High-Capacity, High-Performance, Versatile, Easy-to- Manage Array
  • 39. 39 39 39 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge 3510 FC Array 2Gb Fibre Channel ● 2 rack unit high, up to 12 hot swap, 2Gb fibre channel disk drives RAID ● Single or dual mirrored RAID controllers ● 1GB cache per controller ● Up to 8 direct connect host ports per array ● Seamless array based RAID controller failover ● Up to 1024 LUNs per array Expansion ● Up to 8 JBOD expansion units ● Up to 96 drives per system with expansion units, Up to 16TB Management ● GUI, Web, Terminal Menu, CLI interface ● In and/Out of Band Industry Certifications ● NEBS Level 3 Certified ● MIL STD 810F Compliant for Land, Air, Marine deployment FC Expansion Trays
  • 40. 40 40 40 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge 3511 FC Array SATA Balanced Availability, High Scalability • Dual redundant 2Gb Fibre Channel RAID controllers • 1GB cache/controller • Dual hot-swap power supplies, fans, and controllers • Hot-swappable SATA drives • 12 FC host ports, 12 server configuration without switches • Up to 16TB in a single subsystem with 5 expansion units SATA Expansion Trays
  • 41. 41 41 41 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge™ 6120 Array ●2Gb Fibre Channel Fabric Array ●RAID array , up to 14 HDDs in 3RU high ●H/A configuration, up to 28 HDDs in 6RU high Configuration Flexibility ●Single or dual RAID controller configurations ●1GB or 2GB cache; 1 or 2 ports per array ●64 volumes (LUNs) per array ●Mix and match – RAID 0, 1(1+0), 5 – 36GB/15k; 73GB/10k; 146GB/10k HDDs ●Up to 4 expansion units per array ●7- 84 drives, 504GB – 12.2TB per array Comprehensive Software ●CIM compliant array configuration and health mgmt ●Pre-set Storage Policies ●Volume masking and mapping ●CIM-compliant SAN-wide management ●Solaris fabric multi-path failover and load balancing ●Solaris-based, storage-independent Data Services – Point-in-time copy – Remote replication Sun StorEdge™ 6120 Array (maximum configuration)
  • 42. 42 42 42 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge 6320 System Ethernet Hub Ethernet Hub SAN模块 系统访问面板 FC网络 管理网络 存储模块 管理模块 SSRR 访问 模块化伸缩性和可用性 — 2-22 个 RAID控制器 — 2-22 2Gb fabric 端口 — 可混插并实现 –RAID 0, 1(1+0), 5 –36GB/15k,73GB/10k,& 146GB/10k HDDs –控制器/扩展柜 – 14 – 308 个硬盘;504GB – 45TB – 可选光纤Switch – 集成的管理处理器和远程监控 配置软件 — CIM 兼容的阵列配置和健康管理 — 预先设置的存储策略 — Volume masking and mapping — CIM 兼容的SAM管理 — Solaris fabric 多路径切换和负载 均衡 — CIM:Common Information Model 标准 化接口管理存储设备 SSRR-Sun StorEdge Remote Response
  • 43. 43 43 43 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge™ 6920 Ethernet Hub N1 Data Service Platform FC Network Mgmt. Network Management Module SSRR Access Storage Module System Controller Data Services Management Connectivity Module Ethernet Hub Ethernet Hub MENU
  • 44. 44 44 44 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge™ 6130 • Fully redundant compact design – Dual controllers in 3RU form factor – 2GB of battery-backed cache – Redundant, switched drive connectivity ● High scalable, from 5 to 112 drives – 14 drives/storage module – Up to 8 storage modules/system ● Multiple storage classes (FC/SATA) – FC (10K, 73GB, 146GB) – FC (15K, 73GB) – SATA (7K, 400GB*) ● Dynamically tune volume settings – Multiple RAID levels (0, 1, 1+0, 3, 5) – Multiple and various VDISK sizes – up to 30 drives ● RAID 1 and 1+0, 1+1 up to 15+15 ● RAID 3 and 5, 2+1 up to 29+1 – One or more volumes per VDISK – Relocate VDISKs with complete data and RAID set retention * available within 30 days of release
  • 45. 45 45 45 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge™ 6130 SE6130 – FRONT VIEW SE6130 – BACK VIEW Redundant power supplies and fans help ensure system environmentals Many (4x) 2Gb FC host ports, ideal for redundant SAN deployments Redundant (switched) disk drive connectivity improves availability Redundant RAID controllers mirror IO's for high availability Redundant power supplies ensure against data loss if power fails • Easily see overall system health and status of critical hot-swappable FRUs • 3RU form factor supports up to 5.6TB of storage capacity (SATA) in a single storage module • Key configuration information is secured on every system disk, eliminating system “panic” should a drive fail
  • 46. 46 46 46 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 磁带库产品家族 Sun StorEdge L25, L100, L180 Capacity, Performanc e, Retention & Restore Time Sun StorEdge L700, L5500/6000 Sun StorEdge stand alone drives, L8 Workgroup Backup Scalability, Flexibility For mid-sized business or departments 2.5TB to 34.8 TB Local Backup Small footprint Entry level pricing for small business or departments 20 GB to 1.6 TB Consolidated Backup Massively Scalable Fabric SANs for the enterprise 69TB to 1.1PB
  • 47. 47 47 47 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun StorEdge L8 Tape Autoloader •磁带技术 •LTO、SDLT •接口 •LVD Ultra 160 SCSI HD68 •非压缩容量 •800 GB LTO Gen 1 •1.6 TB LTO Gen 2 •1.3 TB SDLT •传输速率 •15 MB/sec LTO Gen 1 •30 MB/sec LTO Gen 2 •16 MB/sec SDLT •备份软件(bundle or no) •Sun StorEdge Enterprise Backup o • VERITAS NetBackup BusinesServer software •Bar code reader(可选) •Rackmount kit (可选) •主机HBA: X6758A(PCI)
  • 48. 48 48 48 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn The Sun StorEdge L25 Module Two removable magazines (10-cartridge slots with DLTtape & 12-cartridge slots for LTO Ultrium) Available in LVD or HVD base modules Only 4U (7-inches) high Low cost/GB One fixed cartridge location Remote management, barcode reader and redundant power supplies standard LTO Gen1 & 2, DLT8000, SDLT 220 or SDLT 320 drives and media 60MB/sec native performance (with LTO 2) Up to 2 drives x 21 DLTtape or 25 LTO cartridges 5TB native capacity (with LTO 2)  Scalable up to 7 modules in a Sun StorEdge rack (or three L25s and 1 L100)  Robust, tri-axial robotics: small, simple, reliable  Super-quiet operations – virtually silent  Every L25 module is StackLink ready for scalability when you need it  Configurable priority access load port allows for access to cartridges while module is operational
  • 49. 49 49 49 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn The Sun StorEdge L100 Module Under 24-in (13.5U) high per module Available in LVD or HVD base modules Eight removable magazines each with 10 DLTtape or 12 LTO Ultrium cartridges Four fixed data and/or cleaning cartridge slots Priority access load port allows for access to cartridges while module is operational LTO Gen1 & 2, DLT8000, SDLT 220 or SDLT 320 drives and media 180MB/sec native performance (with LTO Gen. 2) 1-5 drives x 84 DLTtape or 100 LTO cartridges 6 drives x 73 DLTtape or 87 LTO cartridges 20TB native capacity (with LTO Gen. 2) ●Scalable up to 7 modules in a Sun StorEdge rack (or three L25s and 1 L100) ●Robust, tri-axial robotics: small, simple, reliable ●Super-quiet operations – virtually silent ●Every L25 module is StackLink ready for scalability when you need it ●Configurable priority access load port allows for access to cartridges while module is operational
  • 50. 50 50 50 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn The Sun StorEdge L180 磁带机技术 SDLT、LTO或9940B,且支持混装 盒式磁带插槽的数量 83、174 磁带驱动器的数量 多达10台DLT8000/LTO、或6个 9940B驱动器 磁带库容量(满配174 磁带) 未压缩容量 LTO 1(每盒磁带100GB) 17.4TB LTO 2(每盒磁带200GB) 34.8TB SDLT320(每盒磁带160GB) 27.8TB 9940B(每盒磁带200GB) 34.8TB 磁带库数据持续传送速率 未压缩容量 LTO(10个驱动器) 150MB/秒 LTO(10个驱动器) 300MB/秒 SDLT320(10个驱动器) 160MB/秒 9940B(6个驱动器) 180MB/秒 接口类型 差份SCSI/SCSI-3/FC
  • 51. 51 51 51 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn The Sun StorEdge L700 磁带机技术 SDLT、LTO或9940B,且支持混装 盒式磁带插槽的数量 228、396、678 磁带驱动器的数量 多达20台DLT8000/LTO、或12个 9940B驱动器 磁带库容量(满配174 磁带) 未压缩容量 LTO 1(每盒磁带100GB) 67.8TB LTO 2(每盒磁带200GB) 135.6TB SDLT320(每盒磁带160GB) 108.5TB 9940B(每盒磁带200GB) 135.6TB 磁带库数据持续传送速率 未压缩容量 LTO(20个驱动器) 300MB/秒 LTO(20个驱动器) 600MB/秒 SDLT320(20个驱动器) 320MB/秒 9940B(12个驱动器) 360MB/秒 接口类型 差份SCSI/SCSI-3/FC
  • 52. 52 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn SUN产品和其他品牌的比较分析 www.sun.com/servers
  • 53. 53 53 53 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn SUN产品和其他品牌的比较分析 • 市场占有率 • 操作系统 • 可靠性 • 投资保护 • 性能 • 发展展望
  • 54. 54 54 54 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun #1 UNIX Platform Server Shipment Market Share Source: IDC's Worldwide Quarterly Server Tracker, February 2004
  • 55. 55 55 55 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 许多在各行业居于领先的公司和企业都选择了Sun的产品 •  Fortune 500中前5名电信大企业中有4家采用Sun的服务器 •  Fortune 500中前5名航空航天大企业中的4家采用Sun的服务器 •  Fortune 500中的5家娱乐业公司中的4家基于Sun的服务器 •  Fortune 100中7家银行中的5家采用Sun的服务器 •  Fortune 1000中所有软件公司中的四分之三采用Sun的服务器 •  80%的因特网应用运行于Sun的系统 •  75%的ISP服务器基于Sun的平台
  • 56. 56 56 56 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn D.H. Brown on RAS 2001 Unix Function Review (OSs @1/01) AIX Update (AIX @ 5/01 & Est. Fall 2001) Still way behind!
  • 57. 57 57 57 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Solaris™ Operating Environment – Compellingly Ahead
  • 58. 58 58 58 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn RAS Strategies IBM pSeries Sun Fire High Reliability Online Maintenance Sun vs IBM Availability Minimizes planned and unplanned downtime Sun Fire servers: ●Highly reliable servers with online maintenance IBM pSeries servers: ●Highly reliable servers that require deferred maintenance ●IBM pSeries lack features needed to minimize planned downtime
  • 59. 59 59 59 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 完全的硬件冗余备份 电源 电源线 冷却 I/O 卡 I/O 组件 CPU/Memory 板 系统控制器 交互连结 自动故障切换系统时钟 Sun IBM HP
  • 60. 60 60 60 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 在线可服务性 Comparison Features Sun Fire 4800-15K IBM p670/p690 Hot Swap CPUs Yes No Hot Swap Memory Yes No Hot Swap I/O Yes PCI Cards Only Hot Swap Service Processors Yes No Hot Swap Power Supplies Yes Yes Hot Swap Fans Yes Partial * Serviceable Partitions Yes No Isolated Hardware Diagnostics Yes No Dynamically Resize Partitions Yes AIX 5.2 only
  • 61. 61 61 61 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 投资保护 CPU/Memory Uniboard PCI Card System Controller I/O Assembly Sun Fireplane Board Fans Power Supply Sun Fire E20K Sun Fire E25K Sun Fire E4900 Sun Fire E6900 Unique Unique Unique Unique • 12,700 Solaris 应用 • 公用组件, 包括Sun Fire Midframe与 15K之间公用的 CPU/Memory 板 • 同样的 UltraSPARC 体系结构 • 通用系统
  • 62. 62 62 62 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire 4800/4900-15K/25K Servers Offer Lower Cost System Upgrades ● Upgrade chassis ● Move key ● components Sun Fire 12K Sun Fire 6800 IBM p670 IBM p690 ● Replace system ● Buy new CPUs ● Buy new memory ● Buy new boards ● Buy new .... Sun Fire Upgrade IBM pSeries Upgrade Leverage your investment Expensive, box swap upgrade Uniboard
  • 63. 63 63 63 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn TPC-C Game 824164 763,898 514034.72 455818 433107 $8.31 $11.50 $28.58 $12.98 $8.28 0 100000 200000 300000 400000 500000 600000 700000 800000 900000 $0 $20 $40 $60 $80 $100 pSeries 690 32-way DB2 tpmC $/tpmC Fujitsu PrimePower 128-way SymfoWARE Sun Fire 15K 72-way tpmC HP Superdome 64-way Oracle10G NEC Express 32-way SQL Server NEC Express 32-way SQL Server
  • 64. 64 64 64 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn OLTP Scaling on ad-hoc Database
  • 65. 65 65 65 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn IBM: Creative CPU Benchmarks IBM's Method* • Take 1 POWER4 core on an 8 core module • Use entire L2 cache • Use all four L3 caches on the multi-chip module. IBM's "Results" 1.3x better SPEC2K #s BUT: >10x area >10x transistors >2.5x power (assumes 7 cores & 3 L2 caches are off) Power4 Benchmark Testbed 32MB 32MB 32MB 32MB >1GHz Core Chip – Chip Communication >1GHz Core 1.5MB L3 1.5MB 1.5MB 1.5MB L3 Dir
  • 66. 66 66 66 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Use SpecRATE not SPEC to Evaluate Large Server Performance IBM 1.7GHz Power4+处理器 Sun SPARCIII 1.2GHz处理器 32 颗 36 - 48颗 比例关系: 1 : 1.1 – 1.5 system cpus GHz base peak base peak SunFire 15K 64 1.2 539 645 390 436 SunFire 15K 48 1.2 414 492 300 336 SunFire 12K 36 1.2 315 379 230 260 SunFire 12K 32 1.2 281 338 206 232 SunFire 12K 28 1.2 254 305 186 208 SunFire 12K 16 1.2 174 145 IBM p690+ 32 1.7 358 372 322 339 IBM p690 32 1.3 251 260 232 249 IBM p690 16 1.3 179 187 144 149 HP Superdome64 64 0.875 267 288 394 413 SunFire6800 8 1.2 70.1 86.1 54.5 61.4 IBM P650-6M2 8 1.45 79.7 82.4 72.7 75.5 fp_rate int_rate Source from Spec.org
  • 67. 67 67 67 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 发展展望
  • 68. 68 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn SUN产品的选型配置 www.sun.com/servers
  • 69. 69 69 69 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 产品配置 • 服务器配置 • 磁盘阵列配置 • 磁带库配置
  • 70. 70 70 70 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun 服务器选型配置 • 应用类型 • 配置性能及扩展性能 • 可靠性、可用性、可服务性 • 投资保护 • 硬件配置
  • 71. 71 71 71 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 服务器选型-应用类型考虑
  • 72. 72 72 72 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 最优化的系统设计 水平扩展 垂直扩展 I/O ● 连续的缓存, 共享内存 多处理器 ● 单操作系统 ● 紧密的内部互连 ● 集群, 多处理器, 非共享内存 ● 多操作系统 ● 松散的外部互连 Memory Switch Network Switch VERTICAL HORIZONTAL CPU MEM I/O CPU MEM I/O CPUMEM I/O CPU MEM I/O I/O CPU MEM CPUMEM I/O CPU MEM I/O CPUMEM I/O CPU MEM I/O CPU MEM I/O CPU MEM I/O CPU MEM I/O I/O CP U CP U MEMMEM I/O I/O CP U CP U MEMMEM I/O CPU CP U MEMMEM I/O
  • 73. 73 73 73 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 水平扩展-最优化系统负载 流媒体 J2EE应用服务 负载均衡 内容缓存 文件和打印 协作计算 Web 服务 目录和身份管理 安全 本地内容缓存
  • 74. 74 74 74 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Application Servers Directory Servers Email Servers 垂直扩展系统的业务负载 OLTP Databases DW/BI CRM/SCM/ERP
  • 75. 75 75 75 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 服务器选型-系统性能考虑 Database Tier Appl- ication Tier DSS OLTP Operational Storage Web Web Web Web Web Apps Server Apps Server Apps Server OLTP Database Web Tier TPC-C SPEC- Jbb ORCL Apps, SAP, PSoft, Seibel, Amdoc, Retek... TPC-W TPC-H, TPC-R, Query Tests APB1, Holos Warehouse Storage Web Web Web Web Web OLAP Data Mart Data Mine DSS Database Neovista, Darwin SPEC- Web
  • 76. 76 76 76 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Benchmark真相 Real World vs. Benchmarks Benchmark Specials (Optimizations) Hard Easy Complexity Simple Complex Real World Workloads TPC-D(1999) SPECrate TPC-D(1997) TPC-C(now) TPC-C(1995) IO Tests Net Tests TPC-H Oracle Apps Peoplesoft SAP SPECjbb Amdocs (1999) Stream BW Volano Benchmark测试意义: • 系统规模配置依据(sizing)。 • 市场宣传(Marketing)。
  • 77. 77 77 77 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 影响系统性能的关键因素 • 处理器 Processor 性能 Performance 吞吐能力 Throughput • 系统内部互连 System Interconnect 延迟 Latency 访问内存数据块所需的时间 内部带宽 Internal bandwidth I/O, Memory与 CPU间的数据传送 • 操作系统 Operating System 可扩展性 Scalability 可靠性 Reliability • 应用优化 Optimized applications
  • 78. 78 78 78 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 服务器选型-可靠性、可用性、可服务性(RAS) • 设备本身的RAS 完全冗余部件 热交换部件 动态重配置 系统自动恢复 系统故障自动跟踪 动态系统域 • 系统架构 负载均衡 替换双通道 HA/Cluster
  • 79. 79 79 79 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 服务器选型- 投资保护 • 通用部件 • 二进制兼容性
  • 80. 80 80 80 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 服务器硬件配置 • 参考Sun 配置指南 • 配置实例(见后面)
  • 81. 81 81 81 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 磁盘阵列选型配置 • 配置性能、容量 • 可靠性、可用性、可服务性 • 硬件配置
  • 82. 82 82 82 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 性能、容量 • 性能指标, 如:IOPS • 数据量要求。 • RAID方式 • 数据扩展要求
  • 83. 83 83 83 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 磁盘阵列选型 -可靠性、可用性、可服务性 • 冗余部件 控制器 冗余通道 RAID方式 • 热交换部件 • 磁盘阵列冗余配置
  • 84. 84 84 84 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 磁盘阵列硬件配置 • 参考Sun 配置指南 • 配置实例(见后面)
  • 85. 85 85 85 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 磁带库选型配置 • 配置性能、容量 • 可靠性、可用性、可服务性 • 备份软件 • 硬件配置
  • 86. 86 86 86 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 磁带库选型 -配置性能、容量 • 备份窗口(时间)- 选择磁带机类型和数量 备份窗口=数据量/备份速度*备份效率 备份速度=数据量/备份窗口*备份效率 • 备份容量 - 选择磁带库容量和磁带数量 备份策略 3-5倍的数据量 • 备份效率:70%
  • 87. 87 87 87 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 磁带库选型 -备份软件 • 备份软件选择 Sun 备份软件 Sun OEM Veritas 备份软件 • 软件配置 软件介质 Server license Client license Application license Tape driver license SAN (Media server license、磁带机共享license等)
  • 88. 88 88 88 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 磁带库硬件配置 • 参考Sun 配置指南 • 配置实例(见后面)
  • 89. 89 89 89 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 配置实例 SE3510 磁盘阵列 以太网 数据库 服务器 V480 数据库 服务器 V480 心跳线 Sun L25 磁盘库 备份服务器 V240 数据库服务器HA
  • 90. 90 90 90 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 配置实例 – 配置V480服务器 2 A37-WBPF2-04GRB Sun Fire V480 Server, 2 * 1.2GHz UltraSPARC III Cu processors with 8MB Ecache each, 4GB memory (16 * 256MB DIMMs), 2 * 73GB 10K rpm FC-AL hard disks, DVD-ROM, 2 * 10/100/1000 ethernet ports, 1 * serial port, 2 * USB ports, 6 * PCI slots, 2 (N+1 redundant) 1 SG-XPCI1FC-QF2 2Gb PCI Single FC Ntwk Adapter 光纤通道卡 2 X3151A Sun Gigaswift Ethernet MMF 2 X3770A Sun(tm) XVR-100 GraphicS 1 X312E CHINESE PWR CRD 电源线 2 X7147A 17" Flat Dispay CRT Monitor 1 X3582A International Type 6 Country Kits Chinese with USB interface 键盘书鼠标 1 数据库服务器 V480,2台, 每台配置2x1.2GHz CPU, 4GB RAM, 2x73GB HDD, 2x2GB FC HBA,2口1000Mbps MMF网卡, 2x100/1000Mbps UTP网卡
  • 91. 91 91 91 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 配置实例 – 配置SE3510磁盘阵列 XTA3510R01A2R365 Sun StorEdge 3510 Fibre Channel Array, Rack Ready, 365-GB (5 x 73-Gbyte 10K RPM disks) w/2 FC-AL HW RAID controllers, 1GB std cache per controller, 2 AC power supplies, 6 SFP's, and Sun StorEdge Configuration Service. 1 XTA-3510-73GB-10K 73GB Fibre Channel, 10Krpm drive 1 X312E CHINESE PWR CRD 电源线 2 X9734A 15M LC to LC FC Optical Cable 光纤 4 XTA-3000-2URK-19U SE3000 2U Univ Rk Rail Kit 上架安装套件 1 NMK9S-00B-99Y9 StorEdge MGMT SW Kit 管理软件 1
  • 92. 92 92 92 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 配置实例 – Sun Cluster配置 CLUZS-999-99M9 the latest update release of Sun Cluster 3.1 media kit, 1 CLA9S-999-99M9 the latest update release of Sun Cluster 3.1 Agent media kit, 1 CLSIS-LCO-G999 SunPlex server license for Sun Fire V480. One license required per server. 2 CLAIS-XXR-9999 SunPlex agent license HA Oracle agent. One license required per cluster. 1
  • 93. 93 93 93 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 配置实例 – Sun V240备份服务器配置 N32-XWB2-9S-202AV2 Sun Fire V240, 2 x 1.28GHz UltraSPARC IIIi, 4 x 512MB DIMMS, 2 x 36GB Drives, 4 x 10/100/1000 Gigabit Ethernet, ALOM Remote Manager, Three PCI Slots, n+1 Redundant Power. 1 X7410A X-Option DVD-ROM 1 X6758A PCI dual channel Ultra3 SCSI host bus adapter 1 X3770A Sun(tm) XVR-100 GraphicS 1 X312E CHINESE PWR CRD 电源线 2 X7147A 17" Flat Dispay CRT Monitor 1 X3582A International Type 6 Country Kits Chinese with USB interface 键盘鼠标 1
  • 94. 94 94 94 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 配置实例 – Sun L25磁带库配置 1 SG-XLIBL25LLV-BASE L25 LTO LVD Base 1 SG-XMEDLTO200GB-10 LTO Gen 2 Media, 200GB, 10pack 1 SG-XMEDLTOUNVCL-10 LTO Univ. Cleaning Cart. 10 PK 1 SG-XTAPLTO2LVD-MOD LTO Gen 2 LVD SCSI - L25/L100 2 X312E CHINESE PWR CRD 1 X3830A 4M CABLE, SCSI 68 TO VHDCI68 1 SG-XMGMTCARDL-MOD Mgmt. Card-for LVD L25/100 1 Sun L25 2xLTO2driver
  • 95. 95 95 95 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 配置实例 – Sun 备份软件配置 1 VNESU-501-9999 VERITAS NetBackup 5.0/5.1 Server and Enterprise Server Media Kit for UNIX and Windows/NT Platforms 1 VNESU-999-W999 VERITAS NetBackup Enterprise Server License on UNIX Platforms which include Solaris, HP-UX, AIX, and Tru64 for Desktop and Workgroup Server Class 1 VOCPL-999-9999 VERITAS NetBackup Option Cross Platform Library Based Tape Drive Support License 2 VCPSS-999-9999 VNBU Protect Client-UNIX Svr 2 VDSOU-999-W999 VNBU DB Agent - Orcl/UNIX-Wkp. 2 Veritas NetBackup Enterprise Server 5.1
  • 96. 96 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Option www.sun.com/servers
  • 97. 97 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn SUN工作站详细介绍 www.sun.com/servers
  • 98. 98 98 98 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Blade 150 工作站 • 64-bit 650-MHz UltraSPARC IIi 处理器, 512KB of Level 2 缓存 • 4 GB DRAM 内存 (4 x 1GB Dimms) • 2x 80GB 7200-RPM 硬盘 • DVDROM (标准), 48xCDRW (可选) • 4x USB 端口,2x IEEE 1394 端口 • 3个全长32 bit/33MHz PCI I/O • 支持1个 XVR-600 入门级 3D 图形卡 • 10/100BASE-T 以太网口 • Solaris 8 12/02 以后的操作系统
  • 99. 99 99 99 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn B150 系统视图
  • 100. 100 100 100 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Blade 1500 工作站 • 1个1.06 GHz UltraSPARC-IIIi CPU, 1MB L2 缓存 • 4 GB内存 (4x 1GB DDR266) • 3.2 GB/s 总线带宽(200 MHz x 128-bit) • 4.2 GB/sec 内存带宽 • 2个80 GB ATA-100 硬盘 • 2个 PCI 总线, 5 PCI 插槽 •2个 64-bit/33MHz, 2x 32-bit/33MHz 插槽 •1 专用总线, 1x 64-bit/66MHz PCI 图形卡插槽 • 支持2个 XVR-600 图形卡 • 4个USB1.1, 3x USB 2.0, 2x IEEE1394 口 • 10/100/1000 Base-T 网口(主板上) • Solaris 8 HW 05/03, Solaris 9 U6 04/04
  • 101. 101 101 101 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn B1500 系统视图
  • 102. 102 102 102 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Blade 2500 工作站 • 2 个1.28GHz UltraSPARC-IIIi CPU, 1 MB L2 缓存 • 8GB DDR-266 ECC 内存 •每CPU 3.2 GB/sec有效系统带宽 • 8.4 GB/sec 内存带宽 • 支持2个高端 XVR-1200 双通道图形卡 • 高吞吐量 • 4个 PCI 总线, 6 PCI 插槽, 2 个专用的图形卡插槽 • 10/100/1000网口 • Solaris 8 HW 05/03, Solaris 9 U6 04/04
  • 103. 103 103 103 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn B2500 系统视图
  • 104. 104 104 104 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn • CPU数量: w1100z 1个,w2100z 2个 • CPU频率:1.8/2.0/2.2/2.4 GHz • CPU L2:1MB • CPU互连:每CPU 3个连接通道,每个通道6.4 GB/s • 内存:每个CPU 4个DIMM槽,512MB/1GB/2GB DIMM, 成对安装 • 网络:1个10/100/1000Mbps RJ45 • 硬盘:2个 U320 SCSI 或ATA • 光驱:DVD-ROM / CD-RW (标准) DVD + R/RW (可选) • PCI-X 槽:5个 64-bit PCI-X slots • 操作系统:Solaris 9 OS (x86),32- and 64-bit Linux, Windows XP Professional Sun w1100z/w2100z 工作站
  • 105. 105 105 105 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun w1100z/w2100z 系统视图
  • 106. 106 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn SUN 工作组(批量)服务器 详细介绍 www.sun.com/servers
  • 107. 107 107 107 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn 工作组(批量)服务器 • Sun Fire V20z and V40z Servers (AMD 32/64bit) • Sun Fire V60x and V65x Servers (Intel XEON) • Sun Fire V210/V240/V250/V440 Server (Ultra SPARC IIIi) • Lights Out Management(LOM) • Remote System Control (RSC) • Sun Netra 20 (Ultra SPARC III) • Sun Fire V480 and V880 (Ultra SPARC III) • Sun Fire V490 and V890 (Ultra SPARC IV)
  • 108. 108 108 108 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V20z • 2个1.6/1.8/2.2 GHz AMD Opteron处理器, 1MB L2 缓存, 1U 可上架 •64-bit / 32-bit 兼容 •CPU-to-CPU 、CPU-to-I/O 2个带宽3.2GB/s通道(6.4GB/s带宽) •16GB DDR1/333 MHz ECC SDRAM 内存 •2 热交换 73GB 10000 转 Ultra320 SCSI 硬盘 • 2个 PCI-X 插槽(1 全长 64-bit/133MHz, 1 半长 64-bits/66MHz) • 2个10/100/1000Mbps 以太网口t • Solaris 9 x86 4/04, 32-bit • Red Hat Enterprise LInux 3.0, 32/64-bit
  • 109. 109 109 109 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V20z 系统视图
  • 110. 110 110 110 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V40z • CPU: 4个 2.4 GHz AMD Opteron 处理器, 1MB L2 缓存 • 带宽: CPU-to-CPU 、CPU-to-I/O links deliver 2x3.2GB/s,(6.4GB/s aggregate) 每个连接 •内存: 32GB DDR1/333 MHz ECC SDRAM • 硬盘:5 个热交换 146GB 10K rpm Ultra320 SCSI • PCI-X插槽:7个PCI-X • 网络: 2个10/100/1000Mpbs RJ45 • 操作系统:Solaris 9 x86 4/04, 32-bit, Red Hat Enterprise LInux 3.0, 32/64-bit
  • 111. 111 111 111 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V40z 系统视图
  • 112. 112 112 112 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V60x and V65x Servers
  • 113. 113 113 113 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V60x Server
  • 114. 114 114 114 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 115. 115 115 115 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V65x Server
  • 116. 116 116 116 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 117. 117 117 117 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V100/V120  550 or 650-MHz UltraSPARCIIi, 512 KB L2 Cache  2 GB Maximum Memory: 4 Slots, 128, 256, or 512 MB PC 133 DRAM DIMMs  80 GB Disk Capacity: 2x 40 GB 7200 RPM IDE Disk Drives  Pre-installed Internal CD-ROM  2 x 10/100BaseT Ethernet Ports, 2 USB Ports IDE disk controller, 2 serial ports  550 or 650-MHz UltraSPARC-IIi, 512 KB L2 cache  4 GB Maximum Memory: 4 slots  256, 512 MB, or 1 GB PC 133 DRAM DIMMs  72 GB Disk Capacity: 2x 36 GB 10,000 rpm hot-swappable UltraSCSI disk drives  Optional CD-ROM or DVD-ROM  Full-length PCI slot  Solaris 8 Operating Environment and LOM preloaded
  • 118. 118 118 118 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Netra 120 Server  650-MHz UltraSPARC-IIi, 512 KB L2 cache  4 GB Maximum Memory: 4 slots  256, 512 MB, or 1 GB PC 133 DRAM DIMMs  72 GB Max Disk Capacity: Up to two 36 GB 10,000 rpm hot-swappable UltraSCSI disk drives  Optional CD-ROM or DVD-ROM  Solaris 8 Operating Environment and LOM preloaded  NEBS Level 3 certified  DC Power Supply
  • 119. 119 119 119 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V120 and Netra 120 背板  2 10/100BaseT  1 UltraSCSI port  PCI card back panel  2 异步串口  ALOM  1 USBs
  • 120. 120 120 120 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V240 Sun Netra 240 Sun Fire V210 Server 高密度服务器解 决方案 高性能 企业级RAS特性 低功耗 Sun Fire V210 /V240 New US-IIIi Systems
  • 121. 121 121 121 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V210 Server
  • 122. 122 122 122 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 123. 123 123 123 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V240 Server
  • 124. 124 124 124 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 125. 125 125 125 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V250 System
  • 126. 126 126 126 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V250 System Overview ● 1-2 UltraSPARC(TM) IIIi 处理器 ● 1.06GHz or 1.280GHz with 1MB On-Chip L2-cache ● On-Chip 64KB data and 32KB instruction cache ● 8GB 内存 (16GB when 2GB DIMMs qualified), 8 DIMM slots ● J-Bus 系统总线时钟 160MHz, 峰值带宽 2.56 GB/sec ● 8个热交换 Ultra160SCSI 36GB or 73GB 10Krpm 硬盘 ● 6个64-bit PCI slots, 3 x 33/66 MHz, 3 x 33 Mhz ● Sun Advanced Lights Out Manager (ALOM) ● 系统配置卡System Configuration Card (SCC) ● 外部端口 : 1 x10/100/1000Base-T, 2 个串口, 1 个并口, 1 Ultra160 SCSI, 4 USB, 管理以太网10Mbps端口 ● DVD-ROM, 可选内置 DDS-4 DAT 磁带机 ● 1+1 冗余电源
  • 127. 127 127 127 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V440 (1) Configuration pricing based on 2P/4GB/4 disk, competitor pricing as of 9/15/03
  • 128. 128 128 128 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 129. 129 129 129 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V480 Server
  • 130. 130 130 130 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 131. 131 131 131 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn CPU/Memory Module
  • 132. 132 132 132 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V880 Server
  • 133. 133 133 133 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 134. 134 134 134 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn System View
  • 135. 135 135 135 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn CPU/MEM Boards
  • 136. 136 136 136 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn I/O Subsystem
  • 137. 137 137 137 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Internal FC-AL Disk Subsystem
  • 138. 138 138 138 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn RAS Features • 热插拔硬盘、PCI槽热交换电源风扇。 • 容易访问内部可替换部件。 • 4级系统诊断 • 可替换通道硬盘、网络 • 独立的远程系统控制模块 • 自动系统恢复
  • 139. 139 139 139 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Automatic System Recovery(ASR)自动系统恢复 • 提供硬件部件失败的自动系统恢复 -CPUs, Memory modules -PCI buses and cards, SCSI bus, FC-AL subsystem - Ethernet interface - USB interface, Serial interfaces • 允许非致命硬件遭受错误和失败后系统重新运行 -自动检测并隔离失效部件 -自动系统重配置能力 -ASR能使系统自动重起动,恢复运行,不需要人为干预
  • 140. 140 © 2004.Teamsun. All rights reserved. Session Number Presentation_ID http://www.teamsun.com.cn Sun Fire V490 & V890 服务器 新产品 www.sun.com/servers
  • 141. 141 141 141 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Sun Fire V490 & V890 Servers CMT UltraSPARC IV now available in sub $50k platforms Up to x2 throughput of previous generation with only 10%-30% higher cost delivering improved price / performance Sun Fire V100/V120 Sun Fire V210/V240 Sun Fire V250 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Fire V890 Sun Fire V490
  • 142. 142 142 142 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn ● Up to 4 UltraSPARC IV 1.05 GHz, dual-threaded processors ● Rack Optimised 5RU package ● Up to 32GB memory, 2 FC- AL disk drives multipathing ready ● 9.6 GB/sec. Sun Fireplane Interconnect ● Six 64 bit PCI slots -- 4 @ 33 MHz, 2 @ 66 MHz ● Dual 10/100/1000-Mbps Ethernet ports ● N+1 Hot Swap Power Supply / Hot Pluggable Disks Sun Fire V490 Server Key Benefits ● Lowest cost platform to incorporate Enterprise Class Sun technologies ● Up to x2 the throughput of the Sun Fire V480 Server – the world's top selling 4P platform in 2003 ● 5RU enclosure maximises Data Center performance and compute density ● Binary compatibility and support for JES ensure faster service deployment & reduced cost and complexity ● Integration with Containers delivers an affordable Consolidation & Migration platform ● Extensive RAS & Remote Management for HA requirements ● Ideal for demanding application and infrastructure services
  • 143. 143 143 143 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn ● Up to 8 UltraSPARC IV 1.2 GHz, dual-threaded processors ● Up to 64GB memory, 12 FC- AL disk drives multipathing ready ● 9.6 GB/sec. Sun Fireplane Interconnect ● Nine 64 bit PCI slots -- 7 @ 33 MHz, 2 @ 66 MHz ● 1 Gb and 10/100 Ethernets, two serial ports, two USB ports ● Integrated FC-AL controller ● Remote Systems Management Card; ALOM+ Hardware and RSC Sun Fire V890 Servers Key Benefits ● Up to x2 the throughput of the Sun Fire V880 Server – the world's top selling 8P platform in 2002 & 2003 ● Binary compatibility and support for JES ensure faster service deployment & reduced cost and complexity ● Integrated, self-contained systems allows efficient integration into IT infrastructure, delivering faster ROI ● Integration with Containers delivers an affordable Consolidation & Migration platform ● Powerful enough for demanding database & application requirements ● Sub $50k price point provides compelling price/performance story
  • 144. 144 144 144 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Highest Performance Platforms See Legal Substantiation slide The Sun Fire V890 delivers the best SPECcpu_rate results in its class demonstrating best performance for application and database services at prices starting below $50k 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 S un Fi re V 890 S P E C i nt _rat e2000 118 S P E C fp_rat e2000 149 I B M p650 S P E C i nt _rat e2000 75 S P E C fp_rat e2000 84 I B M p550 S P E C i nt _rat e2000 65 S P E C fp_rat e2000 84 I B M x445 S P E C i nt _rat e2000 75 N o S P E C fp_rat e2000 R esul t s P ubl i shed H P rp4440-8 S P E C i nt _rat e2000 73 See Legal Substantiation slide All products quoted above have starting prices below $50k Actual configurations used to obtain the above benchmark results vary from $59.2k to $200k+ Sun Fire V890 was configured with 8 Processors / 32GB Memory and has a list price of $123,995
  • 145. 145 145 145 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Customers Recommend Sun Fire V490 & V890 Servers Alain Barlier, Senior Architect OAM Solution Nortel Networks “The Sun Fire V890 Server gave us 1 and a half times the throughput over the Sun Fire V880 Server. We found it not only improves the overall performance of our application, but it also maximizes the uptime and reliability, which is critical for our service level agreements.”
  • 146. 146 146 146 © 2004. Teamsun. All rights reserved. Presentation_ID teamsun.com.cn Customers Recommend Sun Fire V490 & V890 Servers Eric Mottier, Product Manager, OMC Mobile Network Management Alcatel “Alcatel is using Sun Fire V880 Server to host the Alcatel's OMC Mobile Network management. We have successfully tested the UltraSPARCIV Sun Fire V890 Server and we are planning to use the Sun Fire V890 or V490 server for the next releases to optimize our ratio cost/performance.”

Notas do Editor

  1. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  2. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  3. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  4. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  5. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  6. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  7. Sun Delivers Extensive Scalability... Without Forced Migrations This slide illustrates Sun's new Sun Fire Enterprise server product line based on the chip-multithreaded UltraSPARC IV processor as well as Sun's previous-generation Sun Fire V1280-15K server product line based on the UltraSPARC-III processor. Each of these UltraSPARC IV based systems offers up to twice the productivity and computational throughput of their predecessors thanks to Sun's innovative chip multithreading (CMT) technology. Unlike other vendors, Sun accomplishes this scalability without breaking binary compatibility, delivering unprecedented investment protection. All of these servers share the same constant vision and are binary compatible to run the approximately 12,700 available Solaris applications. The new Sun Fire Enterprise product line shares even more with a common system architecture, and common components such as the Sun Uniboard CPU/memory board. This architecture, and key components such as the Uniboard, power servers from the rack-mountable Sun Fire E2900 server all the way through Sun's flagship 72-processor Sun Fire E25K server.
  8. Introducing the Sun Fire E2900, E4900, E6900, E20K, and E25K Servers The new Sun Fire E2900, E4900, E6900, E20K and E25K servers from Sun are powered by new UltraSPARC IV CPU/memory Uniboards. Running across the Sun Fire Enterprise product line, each UltraSPARC IV Uniboard provides four processors (up to eight concurrent threads) and up to 32 GB of memory. For high-end Sun Fire E20K and E25K servers, new I/O enhancements provide up to 60% improvements in I/O performance over previous-generation Sun Fire 12K and 15K servers. These I/O enhancements come from new Sun Fireplane expander boards and new hsPCI+ I/O assemblies.
  9. Sun Fire E20K and E25K Servers: High-Throughput I/O As mentioned, Sun Fire E20K and E25K servers provide enhanced I/O capabilities with up to 60% better I/O performance over the previous-generation hsPCI I/O assembly. These improvements come both a new Sun Fireplane expander board and the new hsPCI+ I/O assembly. In addition to bandwidth improvements, the hsPCI+ I/O assembly supports three 33/66MHz slots and one 33MHz slot providing up to 54 66MHz slots in a single Sun Fire E25K server.
  10. A Scalable Line of Binary-Compatible Servers This slide illustrates the new Sun Fire Enterprise server product line based on the UltraSPARC IV processor. All of the Sun Fire Enterprise servers are configured to run with multiple CPUs, from a minimum of four processors on the Sun Fire E2900 server all the way up to a maximum of 72 processors on the Sun Fire E20K server. With each UltraSPARC IV processor capable of running up to two concurrent threads, these servers deliver up to twice the throughput of previous-generation systems based on the UltraSPARC III processor (Sun Fire V1280-Sun Fire 15K servers). In addition to processor performance, these servers are all designed to support very large memory capacities and very high levels of sustained bandwidth across their system interconnects. As an example, the Sun Fire E25K provides up to 576 gigabytes of system RAM and provides up to 57 gigabytes per second of sustained bandwidth across its Sun Fire plane interconnect. All of the Sun Fire Enterprise servers (except the Sun Fire E2900 server) also provide support for multiple Solaris Operating System domains, enabling multiple completely independent operating system instances to operate on a single hardware server platform. And, of course, all of these systems are binary compatible and the robust Solaris Operating System runs across the product line. Innovative approaches to data center availability such as Sun Remote Systems (SRS) NetConnect are also supported across the product line.
  11. Common Components As mentioned previously, all of the Sun Fire mid-range and high-end servers share a common system architecture. In addition, many actual components are common across the product line as well. This slide illustrates the common components among Sun Fire Enterprise servers. Common CPU/memory, I/O cards and even I/O assembles means that customers can easily move resources between different platform cabinets as needs dictate. This approach greatly simplifies the administration and maintenance of these systems and provides for simpler parts stocking requirements. Note: The Sun Fire E2900 server is excluded from this slide because its components are physically different than those of the other Sun Fire servers, even though they share the same design Transition: Understanding how this common architecture is leveraged across such a broad range of server products requires a brief history of interconnect technology at Sun.
  12. Unprecedented Investment Protection: No Forced Application or OS Migrations All of the new Sun Fire Enterprise servers deliver unprecedented investment protection through Sun's binary compatibility guarantee. Upgrading to UltraSPARC IV technology requires neither changes to applications nor forced operating system migrations as the new Sun Fire Enterprise servers support both the Solaris 8 and 9 Operating Systems. Existing customers' investments are preserved with flexible upgrades that let them move to UltraSPARC IV technology without disruption. Board-level upgrades let customers install UltraSPARC IV Uniboards in their existing Sun Fire V1280-15K servers. Though additional hardware and software upgrades are required for these upgrades, existing systems can continue to operate. Existing UltraSPARC III Uniboards can also be installed in new Sun Fire E2900-E25K servers. Individual Sun Fire data center servers can Sun's mixed-speed CPU support to run UltraSPARC III and UltraSPARC IV Uniboards in the same server, in the same or separate domains. With mixed-speed CPU support all processors continue to run at their rated speeds. Customers can also elect to upgrade entire previous-generation systems to Sun Fire Enterprise servers to take advantage of full factory integration and testing of components. Note: Sun Fire V1280 and Sun Fire E2900 servers share common CPU/memory boards but that these are not physically the same as the Uniboards that run in the rest of the product line.
  13. Full Hardware Redundancy: Redundant, Hot-swappable Components To enable high availability, as well as Dynamic System Domains and Dynamic Reconfiguration, Sun's mid-range and high-end server product line provides full hardware redundancy and key hot-swappable components. Two kinds of redundancy are provided in Sun server systems: N+1 redundant subsystems are truly fault-tolerant in that the subsystem can suffer a failure and remaining components can continue to support the system without affecting operation. Examples of N+1 redundant subsystems in Sun Fire Enterprise servers include redundant system controllers, the system clock, power supplies, and fans. Redundant components, in contrast, may cause a reboot of a domain in the case of failure but their redundancy allows the system to recover in a stable state following the failure. Sun's Automatic System Recovery (ASR) feature allows systems to reboot automatically after a failure, configuring around any failed components in the process. Examples of redundant components include CPU/memory Uniboards, MaxCPU boards, and I/O assemblies. Even the Sun Fireplane ASICs are redundant so that systems can recover from ASIC failures and continue to operate. Sun Fire Enterprise systems also support both redundant network and disk interfaces along with software to manage them.
  14. Fifth-Generation Dynamic System Domains The discussion of Sun's Sun Fire Enterprise product lines begins with the key technology that sets them apart in the marketplace. Dynamic System Domains represent an industry-leading technology, now in its fifth generation that allows Sun's Enterprise servers to be divided into fault-isolated domains, each with their own system resources and separate running instance of the Solaris Operating Environment. Because faults are isolated within each domain, failing software or hardware does not affect the stability of other domains running on the system. In addition to running a separate instance of the Solaris Operating Environment, each domain also has its own security, and assignable administrative roles. This approach lets multiple groups (or even companies) share a single physical hardware system without risk of accidental security breaches or other inadvertent corruption. Dynamic System Domains can also be dynamically reconfigured in response to changing demands — either automatically or manually — literally allowing hardware resources to be added or removed from running domains on an as-needed basis. Processors and memory are configured independently from I/O so that administrators can make fine-grained resource adjustments.
  15. Server Virtualization: Granularity at Every level: Hardware, Operating System, and Application This slide illustrates how Solaris, dynamic reconfiguration, and fault-isolated dynamic system domains can be combined to help drive up utilization in a consolidated environment. Three domains are shown, each running a different version of the Solaris Operating System. Solaris Containers combined with Dynamic System Domains enable a new way to partition systems to achieve higher utilization. The Solaris Next Operating System will enable even more complete fault isolation with trusted containers (next slide) Sun's servers already offer unmatched dynamic configurability that combines closely-coupled hardware resources with flexible resource management software to efficiently support: Resource virtualization Dynamic resource provisioning Large, capacity workloads Hosting of virtual horizontal servers High availability requirements By consolidating onto larger servers with these capabilities, customers can experience drastically-improved resource utilization.
  16. Fifth-Generation Dynamic Reconfiguration Also in its fifth generation, Sun's Dynamic Reconfiguration technology allows hardware components to be added and removed from running domains. CPU/Memory Uniboards, PCI cards, and even entire I/O assemblies containing multiple PCI cards can be added or removed, all without requiring the domain to reboot. This key technology helps enable advanced features such as concurrent repair and maintenance, hot CPU upgrades, and mixed-speed CPU support. Because resources can be added or removed from running domains, system downtime is no longer required for simple upgrades or maintenance. As new or faster processors become available, they can simply be added to running domains without requiring additional down-time. Sun also provides industry-standard WBEM-based Dynamic Reconfiguration (WDR) that allows system resources such as CPU, memory, I/O assembles, and I/O cards to be visible on a WBEM-aware network as manageable resources. (WBEM stands for Web-Based Enterprise management.) This technology enables centralized resource management through a programatic interface that can be used by remote management applications (such as BMC Patrol). Adding to Sun's previous automatic Dynamic Configuration (ADR), this capability enables automated resource management based on either scheduled or programatic controls.
  17. Solaris Trusted Containers: Optimizing System Resource Management Complementing Dynamic System Domains, Solaris Trusted Solaris Containers offer a new way to optimize system resources with arbitrary granularity: Security and fault isolation: Applications are protected from error propagation or security intrusions since each Trusted Container is an isolated, virtual system. Each Trusted Container is shielded from other tenants on that server and each tenant can only see or touch processes in their Trusted Container Taking Cost Out: Trusted Containers share a single instance of the Solaris Operating System, lowering administrative costs. IT departments can greatly accelerate their server consolidation efforts and reduce costs faster with the flexibility of Trusted Containers. Trusted Containers are designed to have very low system overhead focusing system resources on the workload, not the operating system. Investment protection: Existing server settings are easily moved to Trusted Containers since each container allows its own IP address, network namespaces, users, disk, etc. Trusted Containers run on existing Sun systems as well as new SPARC, x86, and Opteron systems. Mission-critical applications run at predictable and protected resource levels, are protected from failures of applications in other Trusted Containers, and can be independently rebooted if necessary. Increased flexibility: Trusted Containers and their resources can be easily configured and manage themselves dynamically via business rules that are set and easily tuned by the administrator. Sharing of unused resources is managed dynamically, automatically maintaining agreed-upon service levels. Usage data is tracked by the Trusted Container allowing IT to demonstrate, and even bill for system resources that are actually delivered.
  18. Sun Cluster Solutions: Sun Cluster 3.0 Sun Cluster solutions delivers high availability through automatic fault detection and recovery along with increased scalability, helping to ensure that mission-critical applications and services are available when needed. Sun Cluster software allows up to eight nodes in a tightly coupled cluster — enough to handle growing numbers of simultaneous users and access to large databases. With Sun Cluster software, administrators can add or remove nodes while online, and mix and match servers to meet specific needs. Individual domains running on Sun Fire mid-range or high-end servers can participate in Sun Cluster 3.0 implementations. With cluster functions integrated into the Solaris kernel, Sun Cluster software extends the Solaris Operating Environment, enabling core Solaris services — devices, file systems, and networks — to operate seamlessly across a tightly coupled cluster. Global cluster file services, device services, and scalable networking services enable full Solaris compatibility for existing applications. Enhanced availability for core services such as file and network service allows existing Solaris applications to benefit from higher availability, more localized failure containment, and faster failover.
  19. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  20. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  21. This slide provides an overview of the key functions of Sun StorEdgeTM 3310 NAS. The top picture shows the front view with the bezel on. The middle picture show the front view, bezel removed, exposing the 12 hot swap disk drives. The bottom picture show the rear view, exposing the RAID controller, power supplies and connectivity ports.
  22. Key points: This is a new generation of storage array that was designed to meet a wide range of application demands. It can do this because it provides an incredible amount of flexibility. And what's unique about the Sun StorEdge™ 6120 array is that it's delivered with a suite of comprehensive software tools to help ensure easy manageability and high data availability.
  23. This slide shows some detailed specs on the L25 module. The modules supports DLT 8000, SDLT 220, SDLT 320 and LTO Ultrium 1 & 2 tape drives. The L25 use two removable magazines, each with 10 DLTtape or 12 LTO Ultrium cartridges (you cannot mix and match DLTtape and LTO Ultrium in the same library module). There are two fixed slots that can be used for data or cleaning cartridges. A single L25 module supports up to two tape drives and 21 DLTtape or 25 Ultrium cartridges. If you stack seven L25 modules in a Sun rack you get up to 14 tape drives and 147 DLTtape or 175 LTO Ultrium cartridges. Thus, you get up to 5TB native with one module and 35TB native with seven modules (using LTO-2) . Up to 60MB/sec native performance is achieved with two drives in one L25 module and 420MB/sec native performance is achieved with 14 drives in seven L25 modules (using LTO-2). Additionally, magazines in the L25 are interchangeable with the L100 and there are no “right or left” side magazines. This eliminates human error and allows for easy bulkloading and removal of cartridge magazines to offsite locations for vaulting purposes or integration in other modules. Many competitors in the L25's market do not come close to the density, performance, and simplicity offered in this product. Sun is clearly leading the market segment with the L25 tape library.
  24. This slide shows some detailed specs on the L100 module. The modules supports DLT 8000, SDLT 220, SDLT 320 and LTO Ultrium 1 & 2 tape drives. The L100 uses eight removable magazines, each with 10 DLTtape or 12 LTO Ultrium cartridges (you cannot mix and match DLTtape and LTO Ultrium in the same library module). There are four fixed slots that can be used for data or cleaning cartridges. A single L100 module supports up to five tape drives and 84 DLTtape or 100 Ultrium cartridges. With six tape drives, one magazine and fixed slot slot is deleted providing storage up to 73 DLTtape or 87 Ultrium cartridges. If you stack two L100 modules in a Sun rack you get up to 10 tape drives and 168 DLTtape or 200 LTO Ultrium cartridges. Thus, you get up to 20TB native with one module and 40TB native with two modules (using LTO-2) . Up to 180MB/sec native performance is achieved with two drives in one 100 module and 360MB/sec native performance is achieved with 12 drives in two L100 modules (using LTO-2). Additionally, magazines in the L100 are interchangeable with the L25 and there are no “right or left” side magazines. This eliminates human error and allows for easy bulkloading and removal of cartridge magazines to offsite locations for vaulting purposes or integration in other modules. Many competitors in the L100's market do not come close to the density, performance, and simplicity offered in this product. Sun is clearly leading the market segment with the L100 tape library.
  25. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  26. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  27. Given these challenges, customers are asking for systems that optimize workloads depending on the applications they are running, at the best price points and at maximum performance. Depending on the application, the best approach could be vertical or horizontal computing, or typically a combination of both. This slide illustrates the reach of systems from the heart of the data center to the network edge. The back-end of the data center will almost always require vertical scalability - large SMP servers – for what we call the data center and application tiers. For workloads running from the edge of the network out to the client tier, horizontally scaled servers are often the most appropriate choice. For high performance technical computing workloads, which span the spectrum from 64-bit graphics workstations to large SMP data base servers, both vertical and horizontally scaled servers come in to play depending on the specific need.
  28. This slide illustrates the differences between vertical and horizontal computing. Vertical servers are large SMP systems with more than four CPUs. There is only one instance of the OS covering the processors, memory and I/O components, generally contained within a single chassis or box. The interconnect is commonly a centerplane or backplane that is tightly coupled, low-latency, high-bandwidth and cahe coherent (which means it maintains information on location of all data regardless of cache or memory location). Resources are added inside the box by adding system boards into the system. Memory is shared, meaning that all processors and all I/O connections have equal access to memory. Memory appears to users as one large chunk. Horizontal computing is the ability to grow the infrastructure for a given application set by adding discrete compute capacity to a pool of clustered, networked servers. Applications suitable for horizontal scaling demonstrate linear increase in capacity with the number of servers in the pool, each running its own OS image, and each with its own processor and memory. Capacity is increased by adding more servers or nodes.
  29. The workloads, or kinds of applications running in this edge enviroment that we are optimizing the design of our horizontal systems to fall into 3 categories: At the client we have traditional Tier 0 or network infrastructure services such as: load balancing, SSL accelerators and SSL/SSH encryption are located here. On the client side, you're looking at departmental Web file and print servers, servers for staging applications, servers for locally caching content and e-mail, some access mechanisms and security mechanisms such as firewall and VPN servers, file and print servers, group calendaring applications, and group collaborative computing. At the Edge or Tier 1 you have web infrastructure services which provide rack and stack web services, caching services, DNS services, directory services and grid computing. Tier 2 or the application tier includes services like Email, network management, portal computing, streaming media and grid computing.
  30. There are various types of applications that are best suited for vertical systems. Applications that are stateful, that require significant amounts of data, users, and large-scale internal data communication are ideal for vertical servers. It typically depends on the workload size rather than the type of application. In the Data Center tier, vertical servers are ideal for very large databases, online transaction processing, mission-critical applications of CRM, SCM, ERP, and datawarehousing and business intelligence. In the application tier, vertical servers are ideal for applications like: -E-mail and groupware -Web application servers -High-performance compute farms -Electronic commerce applications -Business integration applications (EAI) In HPTC, vertical servers are ideal for those applications that have lots of threads that are dependent on and communicate with each other and/or require lots of shared memory.
  31. There are many different benchmarks to demonstrate performance, this slide shows parts of a datacenter that they test. This is one of the reasons that Sun performs a wide variety of benchamrks. It is important to note that when a benchmark tests lots of layers it really only stresses one tier -- for most benchmarks that is the database tier. For TPC-W it now looks like one type of Image servers in the application tier is stressed (so this benchmark might not reveal much useful information for a customer. The TPC-W is so new and there is so much optimizations that are going on a people learn to use this benchmark it is difficult to say what tier is most critical for this benchmark.
  32. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  33. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  34. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.
  35. The Ultra SPARC IIIi processor provides a competitive advantage through 100% binary compatibility, allowing for investment protection and simplification of software licensing maintenance, management of costs and flexibility in upgrades. UltraSPARC IIIi processor is designed with features including integrated L2 cache, memory controllers and 16 GB of addressable memory, all of which lead to lower system cost , lower power consumption and real-world balanced performance with enterprise-class reliability, availability and serviceability (RAS). Only Sun has maintained 15 years of binary compatibility across processor generations allowing customers to protect their huge investments in the UltraSPARC and SolarisTM platform and related costs. The Sun Fire V210/240 and Netra 240 servers are powered by the UltraSPARC IIIi processor and were specifically designed to meet the high throughput demands of the web and application tier with Enterprise-level RAS, while holding the line on power consumption and price.
  36. Welcome. My name is ____________. I'm here to talk to you today about Sun's systems, and how our expansive server line addresses the need for both vertical and horizontal computing in the data center, and why both approaches to computing is important – the differences, the requirements, and the benefits.