Recent hydraulic research on new and in-service PVC pipe has confirmed that industry-recommended flow coefficients are conservative for design of pressure and non-pressure pipes.

Hydraulic Testing
of PVCPipe
Laboratory and FieldTests Confirm
Flow Coefficients
Hydraulic Testing
of PVC Pipe: Laboratory
and Field Tests Confirm
Flow Coefficients
Uni-Bell PVC PipeAssociation
201E.JohnCarpenter Freeway
Suite750
Irving, TX75062
Utah Water Research Laboratory
Utah StateUniversity
8200Old Main Hill
Logan,UT84322-8200
M.E. Simpson Co., Inc.
3406 Enterprise Avenue
Valparaiso,IN46383
June 2023
3
Introduction
Historical Perspective
In North Americamost of thehydraulic researchon PVCpipes wasdone in the1960sand 1970s.Theseearly testsestablished the
followingflow factorsto be used for PVCpipe hydraulicdesign:
Pressurepipe — Hazen Williams (HW) “C”factor = 150
Nonpressure pipe — Manning’s“n”number = 0.009
Sincefriction-factortestingfor PVCpipe in North Americatook placemore than 50yearsago,theUni-BellPVCPipeAssociation
(PVCPA)decidedto engagein atwo-pronged testprogram:(1)laboratory testingof newpipe and (2)fieldtestingof installed pipe.
PVCPAcontractedwithUtah StateUniversity(USU)to:
Perform hydraulic-flowtestingattheUniversity’sUtah Water ResearchLaboratory(UWRL)
Overseefieldtestingof installed PVCpressurepipe
Research Program
Researchgoalswere to:
Measurehydraulic coefficientsfor pressureand nonpressure applications
Determine if establishedcoefficientswereconservativecompared to establishedvalues
Laboratory testingwasperformed atUWRLin Logan,UT,and overseen by ResearchProfessorStevenBarfusswhoisAssociate
Director of UWRL.Fieldtestingwasperformed in WestValleyCity,UT,by M.E.Simpson Co., Inc.,and witnessedby Research
ProfessorBarfuss.
Theresults of both testsaresummarizedin Table1. Theprocedures and testingundertakenare discussedin detail in therest of
this report. Testresults for Darcy-Weisbach“f”areprovidedin Tables 1,4,and 5,but arenot discussedin therest of thisdocument.
TABLE 1: RESULTS OF LABORATORY AND
HYDRAULIC FIELD TESTING ON PVC PIPE
Pipe Age Pipe Size Friction Factor Results
New 6"
HW “C”= 154– 161
Manning’s “n“= 0.0085 – 0.0070
Darcy“f“= 0.012 – 0.017
New 12"
HW “C”= 150– 157
Manning’s “n“= 0.0094 – 0.0077
Darcy“f“= 0.011 – 0.017
46Years 8" HW “C” =164
HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS
4
LABORATORY TESTING
Introduction
Laboratory hydraulics testingwasperformed in March 2022at
theUWRLfacility.Thetestswererun on 6- and 12-inchPVC
pipe to determine threecoefficients:
Hazen-Williams “C”
Darcy-Weisbach “f”
Manning’s“n”
Toimprove accuracyof measurements, minimum pipe length
required was200timespipe insidediameter.Actuallengthfor
the6-inchline was111feet (222timesID)and for the12-inch
line was220feet (220timesID). Figure1showsthetestset-up
for both pipes.Toprovideasmuchdata aspossible, testswere
performed over afull rangeof flowratesunder full operational
pipe conditions for both pipesizes.
Process
Eachtest-sectionset-up included:
Acalibratedflow-meter installed in theupstreampipingt
o
accuratelymeasure flow ratesfor eachtest run
Acontrolvalveto adjust flowratespassingthrough thetest
pipe
Pressuretaps(eachconsistingof ahole through thewallof
thepipe withabrassfitting)to makethetubing connections
Apressuretransmitterto makepressure-loss
measurements betweentheupstreamand downstream
pressuretaps
Flexibletubing to connecteachpressuretapto thehigh and
lowsidesof thepressuretransmitterfor measurements of
pressuredifferentials
After thetestpipes wereinstalled in thelaboratory flume,
woodbracesand nylon strapswereusedto keepthepipes
straight and to hold them in position whenpressurewas
applied.
Flowmeters werecalibratedfor accuracyimmediately prior to
theactualtesting.Foreachtestrun, flowrate through thepipe
and differential pressurealongthelength of thepipe were
measured.Differential-pressure measurements weretaken
from thepressuretapsthat wereinstalled in eachPVCpipe at
theupstreamand downstream ends of eachtestpipe section.
Throughout each test, constant flow wasmaintained through
the pipe length during the run period. Each averaging period
took between3and 5minutes,whichwaslong enough to:
Allowtheflow rateand differential pressureto stabilize
Recordtheactualflowrate through the flow meter
Recordtheaveragepressure differential
Pipe Dimensions
Dimensionsfor 6-inchpipearefound in Table2and for12-inch
pipe in Table3. Inside-diametermeasurements weretakenat
theendsof thetestsections(wherethepressuretapswere
installed). OverallaverageID isshownin eachtable and was
usedto calculateroughness coefficients.
FIGURE 1: 12-INCH AND 6-INCH TEST LINES
(LOOKING DOWNSTREAM)
5
Results
Testresults for the friction coefficienttestsare shownin Table4for 6-inchPVCpipe and in Table5for 12-inchpipe. Darcy “f,”
Manning’s “n,”and Hazen-Williams “C”are listedin eachtable. Flowvelocitieswere2feet per secondand greater asshown.The
coefficientresults for these testsvarywithincreasing Reynolds number, whichisconsistentwiththe Moody Diagram and other
theoretical calculations.
TABLE 2: DIMENSIONS FOR 6-INCH PVC PIPE
Section
ID 1
(in)
ID 2
(in)
ID 3
(in)
Average ID
(in)
1 5.88 5.85 5.88 5.87
2 5.88 5.87 5.85 5.87
3 5.85 5.88 5.89 5.87
Overall Average ID (in) 5.87
Average FlowArea (in2) 27.10
Average FlowArea (ft2) 0.19
TABLE 3: DIMENSIONS FOR 12-INCH PVC PIPE
Section
ID 1
(in)
ID 2
(in)
ID 3
(in)
Average ID
(in)
1 11.69 11.65 11.65 11.66
2 11.63 11.68 11.65 11.65
3 11.60 11.68 11.68 11.65
Overall Average ID (in) 11.65
Average FlowArea (in2) 107.00
Average FlowArea (ft2) 0.74
HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS
6
TABLE 4: TEST RESULTS FOR 6-INCH PVCPIPE
Run
No.
Flow
Volume
(cfs)
Flow
Velocity
(fps)
Inlet
Reynolds
Number
Friction
Loss
(ft of H2O)
Friction
Loss
(psi)
Hydraulic
Slope
(ft/100 ft)
Darcy
“f”
Hazen-
Williams
“C”
Manning‘s
“n”
1 0.5 2.7 84,600 0.42 0.18 0.38 0.017 154 0.0085
2 0.8 4.2 133,000 0.95 0.41 0.85 0.015 157 0.0081
3 1.1 5.7 182,000 1.67 0.72 1.50 0.014 158 0.0078
4 1.4 7.3 230,000 2.54 1.10 2.29 0.014 159 0.0077
5 1.6 8.7 276,000 3.55 1.54 3.20 0.013 159 0.0075
6 1.9 10.2 324,000 4.75 2.06 4.28 0.013 160 0.0074
7 2.2 11.8* 373,000 6.15 2.67 5.54 0.013 160 0.0073
8 2.5 13.3* 422,000 7.67 3.33 6.91 0.013 161 0.0072
9 2.8 14.8* 470,000 9.33 4.04 8.40 0.012 161 0.0072
10 3.1 16.4* 518,000 11.20 4.85 10.09 0.012 161 0.0071
11 3.3 17.8* 564,000 13.10 5.68 11.80 0.012 161 0.0071
12 3.6 19.3* 613,000 15.20 6.60 13.69 0.012 161 0.0070
13 2.0 10.5* 332,000 4.98 2.16 4.48 0.013 160 0.0074
Notes:
1. Length of pipe tested:111.05 feet
2. Dateof calibration:29-Mar-2022
3. Data: watertemperature45°F, unit weight62.2 pcf, kinematicviscosity1.54 x10-5 ft2/sec
*These testruns usevelocitiesthat exceedtypicaldesigns of municipalpipelines
7
TABLE 5: TEST RESULTS FOR 12-INCH PVC PIPE
Run
No.
Flow
Volume
(cfs)
Flow
Velocity
(fps)
Inlet
Reynolds
Number
Friction
Loss
(ft of H2O)
Friction
Loss
(psi)
Hydraulic
Slope
(ft/100 ft)
Darcy
“f”
Hazen-
Williams
“C”
Manning‘s
“n”
1 1.5 2.0 126,000 0.23 0.10 0.10 0.017 150 0.0094
2 2.5 3.4 217,000 0.59 0.26 0.27 0.015 153 0.0089
3 3.5 4.8 304,000 1.10 0.48 0.50 0.014 154 0.0086
4 4.5 6.1 393,000 1.75 0.76 0.79 0.013 155 0.0084
5 5.7 7.7 493,000 2.66 1.15 1.21 0.013 155 0.0082
6 6.7 9.1 581,000 3.57 1.55 1.62 0.012 156 0.0081
7 7.9 10.6 679,000 4.74 2.06 2.15 0.012 156 0.0080
8 8.8 11.9* 761,000 5.83 2.53 2.65 0.012 157 0.0079
9 10.0 13.5* 861,000 7.30 3.16 3.31 0.012 157 0.0078
10 10.9 14.7* 943,000 8.64 3.75 3.92 0.011 157 0.0078
11 12.0 16.3* 1,040,000 10.40 4.49 4.72 0.011 157 0.0078
12 13.5 18.2* 1,170,000 12.80 5.55 5.81 0.011 157 0.0077
Notes:
1. Length of pipe tested:220.29 feet
2. Dateof calibration:28-Mar-2022
3. Data: watertemperature46°F, unit weight62.2 pcf, kinematicviscosity1.52 x10-5 ft2/sec
*These testruns usevelocitiesthat exceedtypicaldesigns of municipalpipelines
Summary of TestResults
Hazen-Williams“C”factor — averagevaluewas159for 6-inchpipe and 155for 12-inch
Manning’s“n”number — averagevaluewas0.0075 for 6-inchpipe and 0.0082 for 12-inch
Darcy-Weisbach“f”factor — valuesrangedfrom 0.012 to 0.017 for 6-inchpipe and 0.011 to 0.017 for 12-inch
In allcases,results obtained verified thetraditional valuesused for thelast40+yearsfor PVCpipe hydraulic design. Theresults also
confirmed that thesevaluesare conservative.
HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS
8
FIELD TESTING
Introduction
Tocorroborate theresults of the laboratory testingdescribed,field testswereperformed by M.E.Simpson in November 2022at
WestValleyCity,UT.Thetestswererun to determine Hazen-Williams“C”for installed 8-inchPVCpressurepipe.Thepipesection that
waschosenfor testinghad been in servicein theGranger-HunterImprovementDistrictsince1976(in servicefor 46years).The field
testswerewitnessedby ResearchProfessorStevenBarfuss,whohad overseen thelaboratory testsdescribed. Oversight included
planning, equipment validation,and testexecution.
Process
Themethod for determining flowcoefficientsisasfollows:
Flowvolumes are measured
Pressurelossismeasuredbetweentwohydrantsspacedataknowndistanceapart
Usingthepressure,flow, and lengthvalues,Hazen-Williams“C”iscalculated
Preparation for thetestsincluded:
Selectionof an appropriate site
Installation of pressuretubing and pressure instrumentation
Installation of flow-measurement instrumentation
Closure of valvesand shut-offof residential connections
Testprocedures included:
Continuousmeasurement of differential pressures
Continuousmeasurement of fluid flow
FIGURE 2: DIFFERENTIAL-PRESSURE INSTRUMENTATION FIGURE 3: FLOW DISCHARGE THROUGH HOSE MONSTER
9
Pipe Dimensions
Arun of 8-inchPVCpipebetweentwohydrantswasused.Distancebetweenthehydrantswas278feet.Pipedimensional
informationisfound in Table6.
Results
Twotestswereperformed on thesamelengthof pipe.Eachtestused adifferentflow velocityto generateadditional data. Test
informationisfound in Table7.
Summary of TestResults
Thefirst testused avelocityof 3.86fps — HW “C”factor was164.2
Thesecondtestused avelocityof 8.73 fps — HW “C”factor w
a
s
163.3
AverageHW“C”factor for thetwotestswas163.8, about 9%higher
than therecommendeddesignof 150
FIGURE 4. EXCAVATED SAMPLES OF PVC WATER
MAINS FOR DIMENSION MEASUREMENT
TABLE 6: DIMENSIONS FOR 8-INCH PVC PIPE
Section
ID 1
(in)
ID 2
(in)
ID 3
(in)
Average
ID
(in)
Pipe
Length
(ft)
1 8.0350 8.0005 7.9960 8.01 278
Overall Average ID (in) 8.01
Average FlowArea (in2) 50.40
Average FlowArea (ft2) 0.35
TABLE 7: DIMENSIONS FOR 8-INCH PVC PIPE
Run No.
Flow
Volume
(gpm)
Flow
Velocity
(fps)
Friction
Loss
(ft of H2O)
Friction
Loss
(ft H2O / ft)
Hazen-
Williams
“C”
1 606 3.86 1.30 0.005 164.2
2 1,370 8.73 5.93 0.021 163.3
Average 163.8
HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS
10
CONCLUSION: PVC PIPE FLOW COEFFICIENTS ARE CONSERVATIVE
Thetwoquestions addressed by hydraulics testingwere answered:
Resultsof hydraulic testingperformed in the1970sareverified
Conservatismof recommendedflowcoefficientswasconfirmed. Testsshowedthat:
Hazen-Williams“C”= 150isconservativefor pressurepipedesign
Manning’s“n”= 0.009 isconservativefor gravitysewerpipedesign
Designersof PVCpipingsystemscanbe confidentthat thesecoefficientshaveprovidedconservativehydraulic designsin thepast
and willcontinue to do soin thefuture. Thereisno need to designwithahigher-friction PVCcoefficient.Thetestingshowsthat even
withvarying flow ratesand long use,theHW“C”factor remainsabove 150and theManning’s“n”staysbelow0.009. Theuseof
higher-friction coefficientsresults in engineeringdesignsthat arenot consistentwithprevious and currentfindings of PVCpipe’s
hydraulic attributes and mayresultin adding unnecessaryproject and operational costs.Thisisshownin thefollowing section.
COMPARISON OF FLOW COEFFICIENTS: RECOMMENDED VS.
CONSERVATIVE
Thissectionprovides examplesof howtheuseof overlyconservativehydraulic values(i.e.,“C”= 120or “n”= 0.013) mayleadto
additional costsfor projectsand pipeline operation (i.e.,increasein pipe size,pumpingcosts,gravitypipe slope, etc.).Actualcost
informationof pipe sizesisnot included.
PVC Water MainExample
AssumeaPVCDR18watermaindesignrequires sizingthepipe for aflow of 1,300gpm whilenot exceedingaheadlossof 10feet
per 1,000feet of pipe.For:
HW“C”factor of 120: 12”PVCDR18wouldbeselected
HW“C”factor of 150: 8”PVCDR18wouldbeselected
PVC Transmission MainExample
Assume20,000feet of 24”PVCDR25pipe conveys5,000gpm,thepump hasan overallefficiencyof 75%whileoperating24hours/
day,and thecostof electricityis$0.10/kWh.Thepumpingcostper year (not including inflation) basedon frictionlossisasfollows:
HW“C”factor of120represents $49,900/year
HW“C”factor of150represents $33,200/year
PVC GravitySewer MainExample
AssumeaPVCPS46sewerpipe designrequires sizingthepipe for aflow of 14cfson aslope of 0.05 feet per 100feet and
maintainingaminimum velocityof 2fps. For:
Manning’s“n”of 0.013: 36”PVCPS46wouldbeselected
Manning’s“n”of 0.009: 30”PVCPS46wouldbeselected
11
THE IMPORTANCE OF USING CONSERVATIVE FRICTION FACTORS
WHEN COMPARING TO OTHER PIPE MATERIALS
Designersshouldrealize that recommendedPVCpipe Hazen-Williams“C”= 150and Manning’s“n”= 0.009 areconservativevalues
compared to testdata. In fact,despite using awiderangeof flow velocities,everydata point in recentresearchhasbeen ator
betterthan theserecommendedvalues.When makingcomparisons withother materials,itisimportant to avoidusing average
valuesfor friction factorsfor hydraulic design,sinceaveragevaluesarenot conservative.Usersareencouraged to reviewtest data
from other pipematerialsto understand howtheir recommendedvalueswereobtained. Additionally,itisessentialthat
recommendedindustry coefficientsinclude anyinternal pipe-wallor pipe-liningdegradation.
ACKNOWLEDGEMENTS
ThePVCPipe Associationexpressesitsappreciation to theGranger-Hunter ImprovementDistrictfor allowinghydraulic testingto
occurin their watersystemand alsoto their employeeswhoactivelyassistedin makingthetests happen.
Uni-Bell PVC PipeAssociation
ThePVCPipe AssociationistheNorth Americantrade associationfor gasketedPVCpipe. Since1971,PVCPAhasbeen the
authoritativesourcefor informationon PVCwater,sewer,and reclaimedwaterpipe.TheAssociationservestheengineering,
regulatory,public health,and standardizationcommunities.
Utah Water ResearchLaboratory
TheUtah WaterResourcesLaboratoryisan internationallyrenownedresearchinstitutionatUtah StateUniversity. Dedicatedin
1965,it istheoldest and one of thelargestwaterresearchlaboratoriesin theUnited States.Thefacilityincludesmore than 113,000
squarefeet of office and laboratory space.UWRLisprimarily focusedon researchin waterand irrigation engineeringand supports
undergraduate and graduate programs in severalsubjectareas.
M.E. Simpson Co.,Inc.
M.E. Simpson wasfounded by Marvin Simpsonin 1979with the objectiveof providing technicalservicesto waterutilities
throughout the Midwest. Sincethen, the company has improved distribution systemperformance for utilities, optimized
distributionsystemdata, and increasedrevenues for watersystemsthroughout theUnited States.
REFERENCES
“Laboratory Testingof PVCPipe Hydraulics,”Water ResearchLaboratory(2022)
“CFactorTestingof an InstalledPVCWaterMain (WitnessTest),”WaterResearchLaboratory (2022)
“Reportfor C-FactorLoss-of-HeadTestingin an InstalledPVCWaterMain,” M.E.Simpson Co.,Inc. (2023)
UNI-TR-7-23
Utah WaterResearch Laboratory
Utah State University
8200 Old Main Hill
Logan, UT84322-8200
M.E. Simpson Co., Inc.
3406 EnterpriseAvenue
Valparaiso, IN 46383
Uni-Bell PVCPipe Association
201 E.John Carpenter Freeway
Suite 750
Irving, TX75062

Mais conteúdo relacionado

Similar a hydraulic-testing-of-pvc-pipe-laboratory-and-field-tests-confirm-flow-coefficients.pptx

Mesa presentation Mesa presentation
Mesa presentation Scott Huskey
314 visualizações56 slides

Similar a hydraulic-testing-of-pvc-pipe-laboratory-and-field-tests-confirm-flow-coefficients.pptx(20)

pipe friction for laminarpipe friction for laminar
pipe friction for laminar
Muhammed Fuad Al-Barznji137 visualizações
Deluge valve angel 6 inch merk vikingDeluge valve angel 6 inch merk viking
Deluge valve angel 6 inch merk viking
Abdul Jalil3K visualizações
Empirical evaluation of different groove feed screw geometriesEmpirical evaluation of different groove feed screw geometries
Empirical evaluation of different groove feed screw geometries
R&B Plastics Machinery2.9K visualizações
pipe friction for laminarpipe friction for laminar
pipe friction for laminar
Muhammed Fuad Al-Barznji88 visualizações
Mesa presentation Mesa presentation
Mesa presentation
Scott Huskey314 visualizações
Well test-procedures-manualWell test-procedures-manual
Well test-procedures-manual
Narendra Kumar Dewangan20.8K visualizações
Well test procedures manualWell test procedures manual
Well test procedures manual
Narendra Kumar Dewangan11.5K visualizações
Pump out tests in alluvial sands – a case studyPump out tests in alluvial sands – a case study
Pump out tests in alluvial sands – a case study
Infocengrs63127 visualizações
Catálogo Williams _ Vdual seal plunger   Catálogo Williams _ Vdual seal plunger
Catálogo Williams _ Vdual seal plunger
Vibropac509 visualizações
Catálogo Williams _ V series Catálogo Williams _ V series
Catálogo Williams _ V series
Vibropac775 visualizações
NONG YAO PROJECT SUBSEA VALVE Rev 0NONG YAO PROJECT SUBSEA VALVE Rev 0
NONG YAO PROJECT SUBSEA VALVE Rev 0
gowri sankar kailasam1.1K visualizações
Quaker final presentationQuaker final presentation
Quaker final presentation
Richard Mastrorilli411 visualizações
pressurized piping LLD testing chattanooga 2015pressurized piping LLD testing chattanooga 2015
pressurized piping LLD testing chattanooga 2015
Don Taylor829 visualizações
singh_rohitendrasingh_rohitendra
singh_rohitendra
Roy Singh1.2K visualizações
2032013040603320320130406033
20320130406033
IAEME Publication309 visualizações
HAZOP.pptHAZOP.ppt
HAZOP.ppt
JayaKarthic131 visualizações
Compact pH Electrode for pure and ultrapure waterCompact pH Electrode for pure and ultrapure water
Compact pH Electrode for pure and ultrapure water
Edress Hauser: Flow Meter, Level, Pressure, Temperature616 visualizações
Testing of Mixed Flow Vertical Turbine PumpTesting of Mixed Flow Vertical Turbine Pump
Testing of Mixed Flow Vertical Turbine Pump
IRJET Journal5 visualizações
Detail product SGS test  2015 - VIB factory.PDFDetail product SGS test  2015 - VIB factory.PDF
Detail product SGS test 2015 - VIB factory.PDF
Alex - Xiamen VIB sanitary ware manufacturer2.2K visualizações

Mais de ManishPatel169454(17)

Pipe Materials GuidePipe Materials Guide
Pipe Materials Guide
ManishPatel16945416 visualizações
pipe_failure_type_6-5-13 (1).pptxpipe_failure_type_6-5-13 (1).pptx
pipe_failure_type_6-5-13 (1).pptx
ManishPatel1694543 visualizações
pipe_failure_type_6-5-13 (1).pptxpipe_failure_type_6-5-13 (1).pptx
pipe_failure_type_6-5-13 (1).pptx
ManishPatel1694544 visualizações
Uni Bell force main design guide for pvc pipe.pptxUni Bell force main design guide for pvc pipe.pptx
Uni Bell force main design guide for pvc pipe.pptx
ManishPatel1694544 visualizações
guide_-_field_cutting_of_pvc_pipes.pdfguide_-_field_cutting_of_pvc_pipes.pdf
guide_-_field_cutting_of_pvc_pipes.pdf
ManishPatel1694543 visualizações
force-main-design-guide-for-pvc-pipe.pdfforce-main-design-guide-for-pvc-pipe.pdf
force-main-design-guide-for-pvc-pipe.pdf
ManishPatel1694543 visualizações
guide_-_field_cutting_of_pvc_pipes.pdfguide_-_field_cutting_of_pvc_pipes.pdf
guide_-_field_cutting_of_pvc_pipes.pdf
ManishPatel1694543 visualizações
guide_-_field_cutting_of_pvc_pipes.pdfguide_-_field_cutting_of_pvc_pipes.pdf
guide_-_field_cutting_of_pvc_pipes.pdf
ManishPatel16945410 visualizações
environmental-product-declaration-2023.pptxenvironmental-product-declaration-2023.pptx
environmental-product-declaration-2023.pptx
ManishPatel16945429 visualizações
environmental-product-declaration-2023.pdfenvironmental-product-declaration-2023.pdf
environmental-product-declaration-2023.pdf
ManishPatel16945416 visualizações
PVC Pressure Pipe Tapping GuidePVC Pressure Pipe Tapping Guide
PVC Pressure Pipe Tapping Guide
ManishPatel16945481 visualizações

Último(20)

Growing Beyond Expectations, 10 Marketing Lessons From Hyper-growth Companies...Growing Beyond Expectations, 10 Marketing Lessons From Hyper-growth Companies...
Growing Beyond Expectations, 10 Marketing Lessons From Hyper-growth Companies...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions28 visualizações
Customer Experience Master Class - Hazem El Zayat, OgilvyCustomer Experience Master Class - Hazem El Zayat, Ogilvy
Customer Experience Master Class - Hazem El Zayat, Ogilvy
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions48 visualizações
Improve Your Digital Experience to Drive More Revenue - Alp Mimaroglu, SyscoImprove Your Digital Experience to Drive More Revenue - Alp Mimaroglu, Sysco
Improve Your Digital Experience to Drive More Revenue - Alp Mimaroglu, Sysco
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions17 visualizações
Conversational AI and PlatinumConversational AI and Platinum
Conversational AI and Platinum
JerryMaurer334 visualizações
Panel - Digital Marketing Trends - Michelle Geere, AdbotPanel - Digital Marketing Trends - Michelle Geere, Adbot
Panel - Digital Marketing Trends - Michelle Geere, Adbot
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions32 visualizações
AZoNetwork Newsletter Audiences 2024.pdfAZoNetwork Newsletter Audiences 2024.pdf
AZoNetwork Newsletter Audiences 2024.pdf
Rebecca73106139 visualizações
How To Build Digital Marketing Strategies - Kuralay Assainova, Liana Technolo...How To Build Digital Marketing Strategies - Kuralay Assainova, Liana Technolo...
How To Build Digital Marketing Strategies - Kuralay Assainova, Liana Technolo...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions52 visualizações
Harnessing the power of FREE behavioral analytics with Microsoft Clarity - Ah...Harnessing the power of FREE behavioral analytics with Microsoft Clarity - Ah...
Harnessing the power of FREE behavioral analytics with Microsoft Clarity - Ah...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions32 visualizações
Digital Marketing Trends - Kuralay Assainova, Liana TechnologiesDigital Marketing Trends - Kuralay Assainova, Liana Technologies
Digital Marketing Trends - Kuralay Assainova, Liana Technologies
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions48 visualizações
Social Media Marketing Master Class - Uptin Saiidi, Up10 MediaSocial Media Marketing Master Class - Uptin Saiidi, Up10 Media
Social Media Marketing Master Class - Uptin Saiidi, Up10 Media
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions49 visualizações
Executive Influence in the Digital Age - Zeev Wexler, Wexler Consulting GroupExecutive Influence in the Digital Age - Zeev Wexler, Wexler Consulting Group
Executive Influence in the Digital Age - Zeev Wexler, Wexler Consulting Group
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions42 visualizações
Creating the Best ChatGPT Prompts - Using Generative AI to Help You Everyday ...Creating the Best ChatGPT Prompts - Using Generative AI to Help You Everyday ...
Creating the Best ChatGPT Prompts - Using Generative AI to Help You Everyday ...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions19 visualizações
How To Actually Turn Cold DMs & Cold Email Systems Into Clients - William Zim...How To Actually Turn Cold DMs & Cold Email Systems Into Clients - William Zim...
How To Actually Turn Cold DMs & Cold Email Systems Into Clients - William Zim...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions34 visualizações
What's new at Ahrefs [end of 2023]What's new at Ahrefs [end of 2023]
What's new at Ahrefs [end of 2023]
Ahrefs38 visualizações
Human Connection in Modern Ecommerce Marketing - Kyle Allison, The Doctor of ...Human Connection in Modern Ecommerce Marketing - Kyle Allison, The Doctor of ...
Human Connection in Modern Ecommerce Marketing - Kyle Allison, The Doctor of ...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions20 visualizações
Panel - Digital Marketing in the New Era of Privacy & Data Governance - Ashle...Panel - Digital Marketing in the New Era of Privacy & Data Governance - Ashle...
Panel - Digital Marketing in the New Era of Privacy & Data Governance - Ashle...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions32 visualizações
Artificial Creativity Master Class - Ivonne Kinser, Vantage Innovation LabArtificial Creativity Master Class - Ivonne Kinser, Vantage Innovation Lab
Artificial Creativity Master Class - Ivonne Kinser, Vantage Innovation Lab
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions17 visualizações
How Brands Are Making Better Digital Marketing Decisions - Neil Pursey, Measu...How Brands Are Making Better Digital Marketing Decisions - Neil Pursey, Measu...
How Brands Are Making Better Digital Marketing Decisions - Neil Pursey, Measu...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions31 visualizações
The Cost of Ignoring Enterprise User Experience - Kevin Richardson, INVIDI Te...The Cost of Ignoring Enterprise User Experience - Kevin Richardson, INVIDI Te...
The Cost of Ignoring Enterprise User Experience - Kevin Richardson, INVIDI Te...
DigiMarCon - Digital Marketing, Media and Advertising Conferences & Exhibitions35 visualizações

hydraulic-testing-of-pvc-pipe-laboratory-and-field-tests-confirm-flow-coefficients.pptx

  • 1. Hydraulic Testing of PVCPipe Laboratory and FieldTests Confirm Flow Coefficients
  • 2. Hydraulic Testing of PVC Pipe: Laboratory and Field Tests Confirm Flow Coefficients Uni-Bell PVC PipeAssociation 201E.JohnCarpenter Freeway Suite750 Irving, TX75062 Utah Water Research Laboratory Utah StateUniversity 8200Old Main Hill Logan,UT84322-8200 M.E. Simpson Co., Inc. 3406 Enterprise Avenue Valparaiso,IN46383 June 2023
  • 3. 3 Introduction Historical Perspective In North Americamost of thehydraulic researchon PVCpipes wasdone in the1960sand 1970s.Theseearly testsestablished the followingflow factorsto be used for PVCpipe hydraulicdesign: Pressurepipe — Hazen Williams (HW) “C”factor = 150 Nonpressure pipe — Manning’s“n”number = 0.009 Sincefriction-factortestingfor PVCpipe in North Americatook placemore than 50yearsago,theUni-BellPVCPipeAssociation (PVCPA)decidedto engagein atwo-pronged testprogram:(1)laboratory testingof newpipe and (2)fieldtestingof installed pipe. PVCPAcontractedwithUtah StateUniversity(USU)to: Perform hydraulic-flowtestingattheUniversity’sUtah Water ResearchLaboratory(UWRL) Overseefieldtestingof installed PVCpressurepipe Research Program Researchgoalswere to: Measurehydraulic coefficientsfor pressureand nonpressure applications Determine if establishedcoefficientswereconservativecompared to establishedvalues Laboratory testingwasperformed atUWRLin Logan,UT,and overseen by ResearchProfessorStevenBarfusswhoisAssociate Director of UWRL.Fieldtestingwasperformed in WestValleyCity,UT,by M.E.Simpson Co., Inc.,and witnessedby Research ProfessorBarfuss. Theresults of both testsaresummarizedin Table1. Theprocedures and testingundertakenare discussedin detail in therest of this report. Testresults for Darcy-Weisbach“f”areprovidedin Tables 1,4,and 5,but arenot discussedin therest of thisdocument. TABLE 1: RESULTS OF LABORATORY AND HYDRAULIC FIELD TESTING ON PVC PIPE Pipe Age Pipe Size Friction Factor Results New 6" HW “C”= 154– 161 Manning’s “n“= 0.0085 – 0.0070 Darcy“f“= 0.012 – 0.017 New 12" HW “C”= 150– 157 Manning’s “n“= 0.0094 – 0.0077 Darcy“f“= 0.011 – 0.017 46Years 8" HW “C” =164
  • 4. HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS 4 LABORATORY TESTING Introduction Laboratory hydraulics testingwasperformed in March 2022at theUWRLfacility.Thetestswererun on 6- and 12-inchPVC pipe to determine threecoefficients: Hazen-Williams “C” Darcy-Weisbach “f” Manning’s“n” Toimprove accuracyof measurements, minimum pipe length required was200timespipe insidediameter.Actuallengthfor the6-inchline was111feet (222timesID)and for the12-inch line was220feet (220timesID). Figure1showsthetestset-up for both pipes.Toprovideasmuchdata aspossible, testswere performed over afull rangeof flowratesunder full operational pipe conditions for both pipesizes. Process Eachtest-sectionset-up included: Acalibratedflow-meter installed in theupstreampipingt o accuratelymeasure flow ratesfor eachtest run Acontrolvalveto adjust flowratespassingthrough thetest pipe Pressuretaps(eachconsistingof ahole through thewallof thepipe withabrassfitting)to makethetubing connections Apressuretransmitterto makepressure-loss measurements betweentheupstreamand downstream pressuretaps Flexibletubing to connecteachpressuretapto thehigh and lowsidesof thepressuretransmitterfor measurements of pressuredifferentials After thetestpipes wereinstalled in thelaboratory flume, woodbracesand nylon strapswereusedto keepthepipes straight and to hold them in position whenpressurewas applied. Flowmeters werecalibratedfor accuracyimmediately prior to theactualtesting.Foreachtestrun, flowrate through thepipe and differential pressurealongthelength of thepipe were measured.Differential-pressure measurements weretaken from thepressuretapsthat wereinstalled in eachPVCpipe at theupstreamand downstream ends of eachtestpipe section. Throughout each test, constant flow wasmaintained through the pipe length during the run period. Each averaging period took between3and 5minutes,whichwaslong enough to: Allowtheflow rateand differential pressureto stabilize Recordtheactualflowrate through the flow meter Recordtheaveragepressure differential Pipe Dimensions Dimensionsfor 6-inchpipearefound in Table2and for12-inch pipe in Table3. Inside-diametermeasurements weretakenat theendsof thetestsections(wherethepressuretapswere installed). OverallaverageID isshownin eachtable and was usedto calculateroughness coefficients. FIGURE 1: 12-INCH AND 6-INCH TEST LINES (LOOKING DOWNSTREAM)
  • 5. 5 Results Testresults for the friction coefficienttestsare shownin Table4for 6-inchPVCpipe and in Table5for 12-inchpipe. Darcy “f,” Manning’s “n,”and Hazen-Williams “C”are listedin eachtable. Flowvelocitieswere2feet per secondand greater asshown.The coefficientresults for these testsvarywithincreasing Reynolds number, whichisconsistentwiththe Moody Diagram and other theoretical calculations. TABLE 2: DIMENSIONS FOR 6-INCH PVC PIPE Section ID 1 (in) ID 2 (in) ID 3 (in) Average ID (in) 1 5.88 5.85 5.88 5.87 2 5.88 5.87 5.85 5.87 3 5.85 5.88 5.89 5.87 Overall Average ID (in) 5.87 Average FlowArea (in2) 27.10 Average FlowArea (ft2) 0.19 TABLE 3: DIMENSIONS FOR 12-INCH PVC PIPE Section ID 1 (in) ID 2 (in) ID 3 (in) Average ID (in) 1 11.69 11.65 11.65 11.66 2 11.63 11.68 11.65 11.65 3 11.60 11.68 11.68 11.65 Overall Average ID (in) 11.65 Average FlowArea (in2) 107.00 Average FlowArea (ft2) 0.74
  • 6. HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS 6 TABLE 4: TEST RESULTS FOR 6-INCH PVCPIPE Run No. Flow Volume (cfs) Flow Velocity (fps) Inlet Reynolds Number Friction Loss (ft of H2O) Friction Loss (psi) Hydraulic Slope (ft/100 ft) Darcy “f” Hazen- Williams “C” Manning‘s “n” 1 0.5 2.7 84,600 0.42 0.18 0.38 0.017 154 0.0085 2 0.8 4.2 133,000 0.95 0.41 0.85 0.015 157 0.0081 3 1.1 5.7 182,000 1.67 0.72 1.50 0.014 158 0.0078 4 1.4 7.3 230,000 2.54 1.10 2.29 0.014 159 0.0077 5 1.6 8.7 276,000 3.55 1.54 3.20 0.013 159 0.0075 6 1.9 10.2 324,000 4.75 2.06 4.28 0.013 160 0.0074 7 2.2 11.8* 373,000 6.15 2.67 5.54 0.013 160 0.0073 8 2.5 13.3* 422,000 7.67 3.33 6.91 0.013 161 0.0072 9 2.8 14.8* 470,000 9.33 4.04 8.40 0.012 161 0.0072 10 3.1 16.4* 518,000 11.20 4.85 10.09 0.012 161 0.0071 11 3.3 17.8* 564,000 13.10 5.68 11.80 0.012 161 0.0071 12 3.6 19.3* 613,000 15.20 6.60 13.69 0.012 161 0.0070 13 2.0 10.5* 332,000 4.98 2.16 4.48 0.013 160 0.0074 Notes: 1. Length of pipe tested:111.05 feet 2. Dateof calibration:29-Mar-2022 3. Data: watertemperature45°F, unit weight62.2 pcf, kinematicviscosity1.54 x10-5 ft2/sec *These testruns usevelocitiesthat exceedtypicaldesigns of municipalpipelines
  • 7. 7 TABLE 5: TEST RESULTS FOR 12-INCH PVC PIPE Run No. Flow Volume (cfs) Flow Velocity (fps) Inlet Reynolds Number Friction Loss (ft of H2O) Friction Loss (psi) Hydraulic Slope (ft/100 ft) Darcy “f” Hazen- Williams “C” Manning‘s “n” 1 1.5 2.0 126,000 0.23 0.10 0.10 0.017 150 0.0094 2 2.5 3.4 217,000 0.59 0.26 0.27 0.015 153 0.0089 3 3.5 4.8 304,000 1.10 0.48 0.50 0.014 154 0.0086 4 4.5 6.1 393,000 1.75 0.76 0.79 0.013 155 0.0084 5 5.7 7.7 493,000 2.66 1.15 1.21 0.013 155 0.0082 6 6.7 9.1 581,000 3.57 1.55 1.62 0.012 156 0.0081 7 7.9 10.6 679,000 4.74 2.06 2.15 0.012 156 0.0080 8 8.8 11.9* 761,000 5.83 2.53 2.65 0.012 157 0.0079 9 10.0 13.5* 861,000 7.30 3.16 3.31 0.012 157 0.0078 10 10.9 14.7* 943,000 8.64 3.75 3.92 0.011 157 0.0078 11 12.0 16.3* 1,040,000 10.40 4.49 4.72 0.011 157 0.0078 12 13.5 18.2* 1,170,000 12.80 5.55 5.81 0.011 157 0.0077 Notes: 1. Length of pipe tested:220.29 feet 2. Dateof calibration:28-Mar-2022 3. Data: watertemperature46°F, unit weight62.2 pcf, kinematicviscosity1.52 x10-5 ft2/sec *These testruns usevelocitiesthat exceedtypicaldesigns of municipalpipelines Summary of TestResults Hazen-Williams“C”factor — averagevaluewas159for 6-inchpipe and 155for 12-inch Manning’s“n”number — averagevaluewas0.0075 for 6-inchpipe and 0.0082 for 12-inch Darcy-Weisbach“f”factor — valuesrangedfrom 0.012 to 0.017 for 6-inchpipe and 0.011 to 0.017 for 12-inch In allcases,results obtained verified thetraditional valuesused for thelast40+yearsfor PVCpipe hydraulic design. Theresults also confirmed that thesevaluesare conservative.
  • 8. HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS 8 FIELD TESTING Introduction Tocorroborate theresults of the laboratory testingdescribed,field testswereperformed by M.E.Simpson in November 2022at WestValleyCity,UT.Thetestswererun to determine Hazen-Williams“C”for installed 8-inchPVCpressurepipe.Thepipesection that waschosenfor testinghad been in servicein theGranger-HunterImprovementDistrictsince1976(in servicefor 46years).The field testswerewitnessedby ResearchProfessorStevenBarfuss,whohad overseen thelaboratory testsdescribed. Oversight included planning, equipment validation,and testexecution. Process Themethod for determining flowcoefficientsisasfollows: Flowvolumes are measured Pressurelossismeasuredbetweentwohydrantsspacedataknowndistanceapart Usingthepressure,flow, and lengthvalues,Hazen-Williams“C”iscalculated Preparation for thetestsincluded: Selectionof an appropriate site Installation of pressuretubing and pressure instrumentation Installation of flow-measurement instrumentation Closure of valvesand shut-offof residential connections Testprocedures included: Continuousmeasurement of differential pressures Continuousmeasurement of fluid flow FIGURE 2: DIFFERENTIAL-PRESSURE INSTRUMENTATION FIGURE 3: FLOW DISCHARGE THROUGH HOSE MONSTER
  • 9. 9 Pipe Dimensions Arun of 8-inchPVCpipebetweentwohydrantswasused.Distancebetweenthehydrantswas278feet.Pipedimensional informationisfound in Table6. Results Twotestswereperformed on thesamelengthof pipe.Eachtestused adifferentflow velocityto generateadditional data. Test informationisfound in Table7. Summary of TestResults Thefirst testused avelocityof 3.86fps — HW “C”factor was164.2 Thesecondtestused avelocityof 8.73 fps — HW “C”factor w a s 163.3 AverageHW“C”factor for thetwotestswas163.8, about 9%higher than therecommendeddesignof 150 FIGURE 4. EXCAVATED SAMPLES OF PVC WATER MAINS FOR DIMENSION MEASUREMENT TABLE 6: DIMENSIONS FOR 8-INCH PVC PIPE Section ID 1 (in) ID 2 (in) ID 3 (in) Average ID (in) Pipe Length (ft) 1 8.0350 8.0005 7.9960 8.01 278 Overall Average ID (in) 8.01 Average FlowArea (in2) 50.40 Average FlowArea (ft2) 0.35 TABLE 7: DIMENSIONS FOR 8-INCH PVC PIPE Run No. Flow Volume (gpm) Flow Velocity (fps) Friction Loss (ft of H2O) Friction Loss (ft H2O / ft) Hazen- Williams “C” 1 606 3.86 1.30 0.005 164.2 2 1,370 8.73 5.93 0.021 163.3 Average 163.8
  • 10. HYDRAULIC TESTING OF PVC PIPE: LABORATORYAND FIELDTESTSCONFIRM FLOWCOEFFICIENTS 10 CONCLUSION: PVC PIPE FLOW COEFFICIENTS ARE CONSERVATIVE Thetwoquestions addressed by hydraulics testingwere answered: Resultsof hydraulic testingperformed in the1970sareverified Conservatismof recommendedflowcoefficientswasconfirmed. Testsshowedthat: Hazen-Williams“C”= 150isconservativefor pressurepipedesign Manning’s“n”= 0.009 isconservativefor gravitysewerpipedesign Designersof PVCpipingsystemscanbe confidentthat thesecoefficientshaveprovidedconservativehydraulic designsin thepast and willcontinue to do soin thefuture. Thereisno need to designwithahigher-friction PVCcoefficient.Thetestingshowsthat even withvarying flow ratesand long use,theHW“C”factor remainsabove 150and theManning’s“n”staysbelow0.009. Theuseof higher-friction coefficientsresults in engineeringdesignsthat arenot consistentwithprevious and currentfindings of PVCpipe’s hydraulic attributes and mayresultin adding unnecessaryproject and operational costs.Thisisshownin thefollowing section. COMPARISON OF FLOW COEFFICIENTS: RECOMMENDED VS. CONSERVATIVE Thissectionprovides examplesof howtheuseof overlyconservativehydraulic values(i.e.,“C”= 120or “n”= 0.013) mayleadto additional costsfor projectsand pipeline operation (i.e.,increasein pipe size,pumpingcosts,gravitypipe slope, etc.).Actualcost informationof pipe sizesisnot included. PVC Water MainExample AssumeaPVCDR18watermaindesignrequires sizingthepipe for aflow of 1,300gpm whilenot exceedingaheadlossof 10feet per 1,000feet of pipe.For: HW“C”factor of 120: 12”PVCDR18wouldbeselected HW“C”factor of 150: 8”PVCDR18wouldbeselected PVC Transmission MainExample Assume20,000feet of 24”PVCDR25pipe conveys5,000gpm,thepump hasan overallefficiencyof 75%whileoperating24hours/ day,and thecostof electricityis$0.10/kWh.Thepumpingcostper year (not including inflation) basedon frictionlossisasfollows: HW“C”factor of120represents $49,900/year HW“C”factor of150represents $33,200/year PVC GravitySewer MainExample AssumeaPVCPS46sewerpipe designrequires sizingthepipe for aflow of 14cfson aslope of 0.05 feet per 100feet and maintainingaminimum velocityof 2fps. For: Manning’s“n”of 0.013: 36”PVCPS46wouldbeselected Manning’s“n”of 0.009: 30”PVCPS46wouldbeselected
  • 11. 11 THE IMPORTANCE OF USING CONSERVATIVE FRICTION FACTORS WHEN COMPARING TO OTHER PIPE MATERIALS Designersshouldrealize that recommendedPVCpipe Hazen-Williams“C”= 150and Manning’s“n”= 0.009 areconservativevalues compared to testdata. In fact,despite using awiderangeof flow velocities,everydata point in recentresearchhasbeen ator betterthan theserecommendedvalues.When makingcomparisons withother materials,itisimportant to avoidusing average valuesfor friction factorsfor hydraulic design,sinceaveragevaluesarenot conservative.Usersareencouraged to reviewtest data from other pipematerialsto understand howtheir recommendedvalueswereobtained. Additionally,itisessentialthat recommendedindustry coefficientsinclude anyinternal pipe-wallor pipe-liningdegradation. ACKNOWLEDGEMENTS ThePVCPipe Associationexpressesitsappreciation to theGranger-Hunter ImprovementDistrictfor allowinghydraulic testingto occurin their watersystemand alsoto their employeeswhoactivelyassistedin makingthetests happen. Uni-Bell PVC PipeAssociation ThePVCPipe AssociationistheNorth Americantrade associationfor gasketedPVCpipe. Since1971,PVCPAhasbeen the authoritativesourcefor informationon PVCwater,sewer,and reclaimedwaterpipe.TheAssociationservestheengineering, regulatory,public health,and standardizationcommunities. Utah Water ResearchLaboratory TheUtah WaterResourcesLaboratoryisan internationallyrenownedresearchinstitutionatUtah StateUniversity. Dedicatedin 1965,it istheoldest and one of thelargestwaterresearchlaboratoriesin theUnited States.Thefacilityincludesmore than 113,000 squarefeet of office and laboratory space.UWRLisprimarily focusedon researchin waterand irrigation engineeringand supports undergraduate and graduate programs in severalsubjectareas. M.E. Simpson Co.,Inc. M.E. Simpson wasfounded by Marvin Simpsonin 1979with the objectiveof providing technicalservicesto waterutilities throughout the Midwest. Sincethen, the company has improved distribution systemperformance for utilities, optimized distributionsystemdata, and increasedrevenues for watersystemsthroughout theUnited States. REFERENCES “Laboratory Testingof PVCPipe Hydraulics,”Water ResearchLaboratory(2022) “CFactorTestingof an InstalledPVCWaterMain (WitnessTest),”WaterResearchLaboratory (2022) “Reportfor C-FactorLoss-of-HeadTestingin an InstalledPVCWaterMain,” M.E.Simpson Co.,Inc. (2023) UNI-TR-7-23
  • 12. Utah WaterResearch Laboratory Utah State University 8200 Old Main Hill Logan, UT84322-8200 M.E. Simpson Co., Inc. 3406 EnterpriseAvenue Valparaiso, IN 46383 Uni-Bell PVCPipe Association 201 E.John Carpenter Freeway Suite 750 Irving, TX75062