International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 
E-ISSN: 2321-9637 
271 
Review Paper on Comparison of Conventional Steel 
Building & Pre-Engineering Building 
Sagar Wankhade1, Prof. Dr. P. S. Pajgade2 
Department of Civil Engineering1, 2, 3, 4, Affiliation name1, 2, 3, 4 
Email: sagarwankhade01@gmail.com1 , ppajgade@gmail.com2 
Abstract-Pre-Engineered Building (PEB) concept is a new conception of single storey industrial building 
construction. This methodology is versatile not only due to its quality pre-designing and prefabrication, but also 
due to its light weight and economical construction. This concept has many advantages over the Conventional 
Steel Building (CSB) concept of buildings with roof truss. This paper is a comparative study of PEB concept 
and CSB concept. 
Index Terms- Industrial steel building, Pre-Engineering Building, IS 875:1987 (LSM) 
1. INTRODUCTION 
An industrial building is any structure that is used to 
store raw materials, house a manufacturing process, or 
store the furnished goods from a manufacturing 
process. Industrial buildings can range from the 
simplest warehouse type structure to highly 
sophisticated structures integrated with a 
manufacturing system. These buildings are low rise 
steel structures characterised by low height, lack of 
interior floor, walls, and partitions. The roofing 
system for such a building is a truss with roof 
covering. Design of basic elements of the structure 
(Roof deck, Purlins, Girders, Columns and Girts) is 
not difficult, but combining them into functional and 
cost effective system is a complex task. 
In Industrial building structures, The walls can be 
formed of steel columns with cladding which may be 
of profiled or plain sheets, GI sheets, precast concrete, 
or masonry. The wall must be adequately strong to 
resist the lateral force due to wind or earthquake. 
COMPONENT OF AN INDUSTRIAL 
BUILDING:- 
The elements of industrial buildings are listed 
below. 
1) Purlins 
2) Sag rods 
3) Principal Rafters 
4) Roof Truss 
5) Gantry Girders 
6) Bracket 
7) Column and Column base 
8) Girt Rods 
9) Bracings 
Fig 1: Various component of Industrial building 
The previous elements are briefly explained below. 
Purlins 
Purlins are beams which are provided over trusses 
to support roof coverings. Purlins spans between top 
chord of two adjacent roof trusses. When purlin 
supports the sheeting and rests on rafter then the 
purlins are placed over panel point of trusses. Purlins 
can be designed as simple, continuous, or cantilever 
beams. Purlins are often designed for normal 
component of forces. the various sections of purlins 
are as follows. 
Fig2: Sections of Purlins 
Sag Rod 
These are round sections rods and are fastened to 
the web or purlin. The roof covering in industrial
International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 
E-ISSN: 2321-9637 
272 
buildings are not rigid and do not provide proper 
support. Therefore, sag rods provided between 
adjacent purlins to extend lateral support for purlins in 
their weaker direction. A sag rod is designed as a 
tension member to resist the tangential component of 
the resultant of the roof load and purlin dead load. 
The tangential component of the roof load is 
considered to be acting on the top flange of purlins, 
whereas the normal component and purlin dead load 
is assumed to act at its centroid. Therefore the sag rod 
should be placed at a point where the resultant of 
these forces act. 
Fig 3: Sag rod 
Principal rafter 
The top chord member of a roof truss is called as 
principal rafter. They mainly carry compression but 
they may be subjected to bending if purlins are not 
provided at panel points. 
Roof Trusses 
Roof trusses are elements of the structure. The 
members are subjected to direct stresses. Truss 
members are subjected to direct tension and direct 
compression. 
Gantry Girder 
Gantry girders are designed as laterally 
unsupported beams. Overhead travelling cranes are 
used in industrial buildings to lift and transport heavy 
jobs, machines, and so on, from one place to another. 
They may be manually operated or electrically 
operated overhead travelling crane. A crane consists 
of a bridge made up of two truss girders which moves 
in the longitudinal direction. To facilitate movement, 
wheels are attached to the ends of crane girders. These 
wheels move over rails placed centrally over the 
girders which are called gantry girders. 
Fig 4: Gantry Girder 
Brackets 
Brackets types of connections are made whenever 
two members to be secured together do not intersect. 
Fig 5: Brackets 
Column and Column Base 
A column is a structural member which is straight 
to two equal and opposite compressive forces applied 
at the ends. Stability plays an important role in the 
design of compression member because in columns 
buckling is involved. The problem of determining the 
column load distribution in an industrial building 
column is statically indeterminate. To simplify the 
analysis the column is isolated from the space frame 
and is analyzed as a column subjected to axial load 
and bending. 
An industrial building column is subjected to 
following loads in addition to its self weight. 
1) Dead load from truss 
2) Live load on roof truss 
3) Crane load 
4) Load due to wind 
Steel columns are normally supported over concrete 
blocks. However when the load supported by these 
columns are large and the bearing pressure of concrete 
from below is insufficient to resist the loads, they may 
fail. Therefore it is a normal practice to distribute 
column loads to steel base plate which are placed over 
these concrete blocks. In addition to transferring 
safely the column loads, a base plate also maintains 
the alignment of the column in plane, verticality of the 
column and controls column and frame deflection.
International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 
E-ISSN: 2321-9637 
273 
Fig 6: Column and column base 
Girt 
These are beams subjected to unsymmetrical 
bending. These support vertical dead load from the 
sliding and horizontal wind loads. Usually these are 
unequal angle sections connected with the longer leg 
to withstand the effect of wind. Girts are assumed to 
be continuous. 
Bracing 
It is important to trace the longitudinal crane forces 
through the structure in order to insure proper wall 
and crane bracing. For lightly loaded cranes, wind 
bracing in the plane of the wall may be adequate for 
resisting longitudinal crane forces. While for every 
large longitudinal forces, the bracing is most likely to 
be required in the plane of crane rail. 
When the wind acts in the direction normal to the 
plane of industrial building bents, i.e., in the 
longitudinal direction, then it becomes essential to 
brace it to another to provide sufficient stability 
against wind or other longitudinal force. Vertical 
column bracing transfers the longitudinal force to the 
foundation. 
Fig 7: Bracing 
2. VARIOUS LOADS ON AN INDUSTRIAL 
BUILDING 
Dead load 
The dead load of truss includes the dead load of 
roofing materials, purlins, trusses and roof bracing 
systems. The dead weight of the trusses may be 
assumed to be equal to 10% of the load on the truss. 
The weight of the bracing may be assumed to be 12- 
15 N/m2 of the plan area. A simple for the estimation 
of the approximate dead weight of the roof truss in 
N/m2. 
Superimposed loads 
The load assumed to be produced by the intended 
use of occupancy of a building, including the self 
weight of movable partitions, distributed, 
concentrated loads, loads due to impact and vibration 
sand dust load but excluding wind, seismic, snow and 
other loads due to temperature changes, creep, 
shrinkage, differential settlement etc IS: 875 (part 2) 
1987 specifies live loads to be assumed in the analysis 
of an industrial building. 
Wind load 
The most critical load on an industrial building is the 
wind load. For the roof and walls of an industrial 
building, consideration must be made for pressure 
difference between the opposite faces of such 
elements to accounts for external and internal air 
pressures exerted by wind blowing against the 
building. When the negative air pressure is less than 
the atmospheric pressure is known as suction. IS 875 
(part 3) 1987 specifies the following wind load 
coefficients to be assumed in the analysis of an 
industrial building. 
The wind force F is obtained by an equation 
F= (Cpe – Cpi ) APz 
Snow load 
IS 875 (part 4) 1987 specifies the following snow 
load to be assumed in the analysis of an Industrial 
building. If the structure is situated in an area where 
the roof is subjected to snow, the load considered for 
design should be the maximum of live or snow load. 
The load due to snow depends upon the pitch of the 
roof, shape of the roof and roofing material. Snow 
load may be assumed to be 2.5 N/m2 per mm depth of 
snow. When the roof slope is greater than 50 degree 
Snow load may be neglected. 
3. AN OVERVIEW OF THE CONCEPT OF 
PRE -ENGINEERING BUILDINGS 
The scientific-sounding term pre-engineered 
buildings came into being in the 1960s. The buildings 
were pre-engineered because they rely upon standard 
engineering designs for limited number 
configurations. These buildings are mostly custom 
designed metal building to fill the particular needs of 
customer. 
Basically, a PEB is a rigid jointed plane frame 
from hot-rolled or cold – rolled sections, supporting 
the roofing and side cladding via hot-rolled or cold-formed 
purlins and sheeting rails. Pre Engineered 
Buildings offers many advantage such as more 
effective use of steel than in simple beams, easy 
extension at any time in the future and ability to
International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 
E-ISSN: 2321-9637 
274 
support heavy concentrated loads. PEB frames have a 
roof slope of from 6 to 12 degree, mainly chosen 
because of the smaller volume of air involved in 
heating and cooling the building. Usually, the portal 
frames are composed of tapered stanchions and 
rafters. Most often, the beam is tapered by providing a 
slope to the flange for water runoff and keeping the 
bottom flange horizontal for ceiling applications. 
The main reason for the popularity of the gabled 
rigid- frame system lies in its cost efficiency. It 
requires less metal than most other structural systems 
of the same span and eave height. 
A typical single-storey metal building system is 
supported by main frames forming a number of bays. 
Bay size is the space between frame centerlines 
measured along the sidewall. Frame clear span is the 
clear distance between frame columns. Metal building 
system can have a variety of wall materials, the 
original and still the most popular being metal siding, 
supported by sidewall or end wall girts. 
Fig 8: Various component of PEB 
4. COMPONENT OF A PRE-ENGINEERED 
BUILDING 
The component of a PEB may be broadly divided into 
following four parts, namely 
1) Main Frame 
2) Secondary Frame 
3) Wind Bracing 
4) Exterior cladding 
Main Frame 
Moment resisting frames provides lateral stability and 
transfer the roof and wall load to the foundation 
through anchor bolts. Main frames are built up 
tapered or constant depth column and rafters. The 
tapered profile is based on the moment diagram of the 
structure, which results in greater economy compare 
to any other structure. This is the main difference with 
respect to other structural steel frame building where 
in straight columns and beams are used. The tapered 
sections are welded using automatic welding machine 
to ensure high quality and rapid construction. Flanges 
are welded to the web by a continuous single side 
fillet weld. Splices using flange plate are usually 
provided at the zones of low moment in the frame. 
Secondary Frame 
Purlins girts and eves struts are secondary structural 
members used to support the wall and roof panels. 
Purlins are used on the roof, girts are used on the 
walls and eave struts are used at the intersection of the 
sidewall and the roof. Purlins and Girts provide lateral 
bracing to the building columns, rafter and prevents 
lateral buckling of compression flanges. Purlins and 
Girts are usually Cold Rolled steel C or Z sections 
having minimum yield strength of 345 Mpa. Z shaped 
purlins are usually adopted for PEB since this shape 
provides greater advantage of being lapped at support 
points and nested together to increase the stiffness. C 
section on the other hand lacks this capability. 
Wind Bracing 
Roof and wall cross bracing provide longitudinal 
stability to the building. It enables effective transfer of 
wind load acting on building end walls to the 
foundation. 
Exterior Cladding 
Exterior Cladding provides a water tight envelope. It 
transfers the Structural loads i.e. Wind and Live load 
to the Secondary Framing. It provides lateral bracing 
to the Purlin and girt. 
5. STABILITY OF A PRE-ENGINEERED 
BUILDING 
A building lacking lateral stability against wind and 
earthquake loads will not be standing for long. The 
most popular Pre-Engineered structure, rigid frame, 
relies on its own moment resisting ability to laterally 
support the building. 
A typical design solution for metal building systems is 
to provide moment- resisting frames spanning the 
short direction of the building and braced frames in 
the exterior walls. The vertical bracing located in the 
end wall acts primarily in resisting lateral loads acting 
in the direction parallel to the frames, while the 
sidewall bracing resists the loads in trhe perpendicular 
direction. 
6. COMPARISON OF PRE-ENGINEERED 
STEEL BUILDINGS OVER 
CONVENTIONAL STEEL BUILDINGS 
PRE-ENGINEERED 
STEEL 
BUILDINGS 
CONVENTIO 
NAL STEEL 
BUILDINGS 
Structure 
Weight 
Pre-engineered 
buildings are on an 
average 30% lighter 
through efficient use 
of steel. Primary 
members are 
tapered built up 
sections, with large 
depths in the ares of 
highest stress. 
Primary steel 
members are 
selected from 
standard hot 
rolled I section, 
which are, in 
many segments 
of the 
members, 
heavier than 
what is actually 
required by
International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 
E-ISSN: 2321-9637 
275 
design. 
Members have 
constant cross-sections 
regardless of 
the varying 
magnitude of 
the local 
stresses along 
the member 
length. 
Design Specialized 
computer analysis 
and dedign 
programs optimize 
material required. 
Drafting is also 
computerized using 
standard details that 
minimize use of 
project custom 
details. 
Substantial 
engineering 
and detailing 
work is 
required on 
every project. 
Generalized 
computer 
analysis 
programs 
requires 
extensive 
input/output 
and design 
alterations. 
Delivery Average 6 to 8 
weeks. 
Average 20 to 
26 weeks. 
Foundations Simple design, easy 
to construct and 
light weight. 
Extensive, 
havy 
foundations 
required. 
Erection 
Simplicity 
Since the 
connections of the 
components are 
standard, the 
learning curve of 
erection for each 
subsequent project 
is faster. 
The 
connections are 
normally 
complicated 
and differ from 
project to 
project, 
resulting in 
longer learning 
curves of 
erection for 
new project. 
Erection Cost 
& Time 
Both costs and time 
of erection are 
accurately known 
based 
upon extensive 
experience with 
similar buildings. 
Typically 
conventioonal 
steel buildings 
are 20% more 
expensive than 
PEB. In most 
of the cases the 
erection cost 
and time arenot 
estimated 
accurately. 
Seismic 
Resistance 
The low-weight 
flexible frames offer 
higher resistance to 
seismic force. 
Rigid heavy 
weight 
structures do 
not perform 
well in seisnic 
zones. 
Overall price Price per square 
meter may be as 
much as 30% lower 
than conventional 
building. 
Higher price 
per square 
meter. 
Architecture Outstanding 
architectural design 
can be achieved at 
low cost using 
standard 
architectural 
features and 
interface details 
Special 
architectural 
design and 
features must 
be developed 
for each 
project, which 
often require 
research and 
resuls in higher 
cost. 
Future 
Expansion 
All project records 
are safely and 
orderly kept in 
electronic format 
indefinitely, making 
it easier for owner 
or designer to obtain 
a copy of his 
building records at 
any time. 
It would be 
difficult to 
obtain records, 
after a long 
period of time. 
It is required to 
contact more 
than one party, 
involved in 
project, to 
obtain accurate 
information. 
Safety and 
responsibilitie 
s 
Single source of 
supply results in 
total responsibility 
by one supplier, 
including design 
liability. 
Multiple 
responsibilities 
can result in 
question of 
who is 
responsible 
when 
components do 
not fit 
properly, 
insufficient 
material is 
supplied, or 
materials fail to 
perform. 
Performance All components 
have been specified 
and designed 
specifically to act 
together as asystem 
for maximum 
efficiency, precise 
fit and peak 
performance in the 
field. 
Components 
are custom 
designed for 
specific 
application on 
a specific job. 
Design and 
detailing errors 
are possible 
when 
assembling the 
diverse 
compoments in 
unique 
building. 
7. ADVANTAGES OF STEEL 
CONSTRUCTION 
1. High quality, aesthetic 
2. Lower maintenance costs
International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 
E-ISSN: 2321-9637 
276 
3. Non combustible to fire 
4. Steel is environmentally friendly 
5. Components can be used again and again 
6. Steel components are frequently functional 
7. Steel construction is strong, durable and stable 
8. Steel Construction promotes good design and 
safety 
9. Construction with Steel is sustainable to 
Temperature effects 
10. Steel frame construction is rigid in structure and 
dimensionally stable 
11. Steel can be re-used without effecting the 
environment 
12. Construction with Steel components is very fast 
compared to other materials 
13. Steel construction of buildings with steel 
components is resistant to termites and other 
destructive insects. 
14. Steel constructions are cheaper than any other 
construction methods 
15. Steel construction is a fast method of construction 
8. APPLICATION OF PEB 
The most common applications of Pre-Engineered 
Buildings are: 
1) Factories 
2) Steel Mills 
3) Sports Stadiums 
4) Shipyards 
5) Logistic Centres 
6) Waste Treatment Factories 
Fig 9: Logistic centre 
Fig 10: Shipyards 
CONCLUSION 
This paper effectively conveys that PEB structures 
can be easily designed by simple design procedures in 
accordance with country standards. In light of the 
study, it can be concluded that PEB structures are 
more advantageous than CSB structures in terms of 
cost effectiveness, quality control speed in 
construction and simplicity in erection. The paper also 
imparts simple and economical ideas on preliminary 
design concepts of PEBs. The concept depicted is 
helpful in understanding the design procedure of PEB 
concept. 
REFERENCES 
[1] International Journal of Engineering Sciences & 
Emerging Technologies, June 2013. ISSN: 2231 
– 6604 Volume 5, Issue 2, pp: 75-82 
[2] Syed Firoz, Sarath Chandra Kumar B, 
S.Kanakambara Rao, Design Concept Of Pre 
Engineered Building, International Journal of 
Engineering Research and Applications (IJERA) 
Vol. 2, Issue 2,Mar-Apr 2012, pp.267-272. 
[3] Dr. N. Subramanian Computer Design 
Consultants Gaithersburg, MD 20878, USA Pre- 
Engineered Buildings Selection of Framing 
System, Roofing & Wall Materials 
[4] Dr. V. L. Shah & Prof. Mrs Vina Gore, Limit 
state Design of Steel Structure 
[5] S. K. Duggal, Limit State Design of Steel 
Structure.

Mais conteúdo relacionado

Mais procurados

Connection and Bracing
Connection and BracingConnection and Bracing
Connection and Bracingsuddal
 
Virtual Outriggers in Tall Buildings
Virtual Outriggers in Tall BuildingsVirtual Outriggers in Tall Buildings
Virtual Outriggers in Tall BuildingsAndrew J Horton
 
Pre enginnered buildings master-builder_july08, pp.48-62
Pre enginnered buildings master-builder_july08, pp.48-62Pre enginnered buildings master-builder_july08, pp.48-62
Pre enginnered buildings master-builder_july08, pp.48-62hlksd
 
Performance of High-Rise Steel Building With and Without Bracings
Performance of High-Rise Steel Building With and Without BracingsPerformance of High-Rise Steel Building With and Without Bracings
Performance of High-Rise Steel Building With and Without BracingsIJERA Editor
 
BRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKEBRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKESajid Iqbal
 
Topology optimisation of braced frames for high rise buildings
Topology optimisation of braced frames for high rise buildingsTopology optimisation of braced frames for high rise buildings
Topology optimisation of braced frames for high rise buildingsIAEME Publication
 
IJSRED-V2I4P17
IJSRED-V2I4P17IJSRED-V2I4P17
IJSRED-V2I4P17IJSRED
 
Trussteel design-manual-2012
Trussteel design-manual-2012Trussteel design-manual-2012
Trussteel design-manual-2012Kashif Khan
 
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...Hossam Shafiq II
 
Analysis of Beam-Column Joint subjected to Seismic Lateral Loading – A Review
Analysis of Beam-Column Joint subjected to Seismic Lateral Loading – A ReviewAnalysis of Beam-Column Joint subjected to Seismic Lateral Loading – A Review
Analysis of Beam-Column Joint subjected to Seismic Lateral Loading – A ReviewIRJET Journal
 
Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...
Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...
Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...Ursachi Răzvan
 
Drift analysis and Comparison due to rigid frame structure
Drift analysis and Comparison due to rigid frame structureDrift analysis and Comparison due to rigid frame structure
Drift analysis and Comparison due to rigid frame structureFarok Ahmed
 
Design of industrial roof truss
Design of industrial roof truss Design of industrial roof truss
Design of industrial roof truss Sudhir Gayake
 
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...Hossam Shafiq II
 
L3 Vertical Structure Pt1 1
L3  Vertical  Structure  Pt1 1L3  Vertical  Structure  Pt1 1
L3 Vertical Structure Pt1 1chuhonsan
 
Lecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering Iaşi
Lecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering IaşiLecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering Iaşi
Lecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering IaşiUrsachi Răzvan
 
PPT ON DESIGN OF COLUMN BRACES
PPT ON DESIGN OF COLUMN BRACESPPT ON DESIGN OF COLUMN BRACES
PPT ON DESIGN OF COLUMN BRACESsrinivas cnu
 
Connections in steel structures
Connections in steel structuresConnections in steel structures
Connections in steel structuresRizwan Khurram
 
Ductile detailing IS 13920
Ductile detailing IS 13920Ductile detailing IS 13920
Ductile detailing IS 13920INTEZAAR ALAM
 

Mais procurados (20)

Connection and Bracing
Connection and BracingConnection and Bracing
Connection and Bracing
 
Virtual Outriggers in Tall Buildings
Virtual Outriggers in Tall BuildingsVirtual Outriggers in Tall Buildings
Virtual Outriggers in Tall Buildings
 
Bracing connections
Bracing connectionsBracing connections
Bracing connections
 
Pre enginnered buildings master-builder_july08, pp.48-62
Pre enginnered buildings master-builder_july08, pp.48-62Pre enginnered buildings master-builder_july08, pp.48-62
Pre enginnered buildings master-builder_july08, pp.48-62
 
Performance of High-Rise Steel Building With and Without Bracings
Performance of High-Rise Steel Building With and Without BracingsPerformance of High-Rise Steel Building With and Without Bracings
Performance of High-Rise Steel Building With and Without Bracings
 
BRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKEBRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKE
 
Topology optimisation of braced frames for high rise buildings
Topology optimisation of braced frames for high rise buildingsTopology optimisation of braced frames for high rise buildings
Topology optimisation of braced frames for high rise buildings
 
IJSRED-V2I4P17
IJSRED-V2I4P17IJSRED-V2I4P17
IJSRED-V2I4P17
 
Trussteel design-manual-2012
Trussteel design-manual-2012Trussteel design-manual-2012
Trussteel design-manual-2012
 
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...
Lec01 Design of RC Structures under lateral load (Earthquake Engineering هندس...
 
Analysis of Beam-Column Joint subjected to Seismic Lateral Loading – A Review
Analysis of Beam-Column Joint subjected to Seismic Lateral Loading – A ReviewAnalysis of Beam-Column Joint subjected to Seismic Lateral Loading – A Review
Analysis of Beam-Column Joint subjected to Seismic Lateral Loading – A Review
 
Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...
Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...
Lecture 2 s.s. iii continuare Design of Steel Structures - Faculty of Civil E...
 
Drift analysis and Comparison due to rigid frame structure
Drift analysis and Comparison due to rigid frame structureDrift analysis and Comparison due to rigid frame structure
Drift analysis and Comparison due to rigid frame structure
 
Design of industrial roof truss
Design of industrial roof truss Design of industrial roof truss
Design of industrial roof truss
 
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...
 
L3 Vertical Structure Pt1 1
L3  Vertical  Structure  Pt1 1L3  Vertical  Structure  Pt1 1
L3 Vertical Structure Pt1 1
 
Lecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering Iaşi
Lecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering IaşiLecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering Iaşi
Lecture 9 s.s.iii Design of Steel Structures - Faculty of Civil Engineering Iaşi
 
PPT ON DESIGN OF COLUMN BRACES
PPT ON DESIGN OF COLUMN BRACESPPT ON DESIGN OF COLUMN BRACES
PPT ON DESIGN OF COLUMN BRACES
 
Connections in steel structures
Connections in steel structuresConnections in steel structures
Connections in steel structures
 
Ductile detailing IS 13920
Ductile detailing IS 13920Ductile detailing IS 13920
Ductile detailing IS 13920
 

Destaque

Paper id 35201569
Paper id 35201569Paper id 35201569
Paper id 35201569IJRAT
 
Paper id 41201606
Paper id 41201606Paper id 41201606
Paper id 41201606IJRAT
 
Paper id 28201439
Paper id 28201439Paper id 28201439
Paper id 28201439IJRAT
 
Paper id 37201539
Paper id 37201539Paper id 37201539
Paper id 37201539IJRAT
 
Paper id 312201534
Paper id 312201534Paper id 312201534
Paper id 312201534IJRAT
 
Paper id 312201516
Paper id 312201516Paper id 312201516
Paper id 312201516IJRAT
 
Paper id 24201443
Paper id 24201443Paper id 24201443
Paper id 24201443IJRAT
 
Paper id 36201532
Paper id 36201532Paper id 36201532
Paper id 36201532IJRAT
 
Paper id 23201411
Paper id 23201411Paper id 23201411
Paper id 23201411IJRAT
 
Paper id 41201604
Paper id 41201604Paper id 41201604
Paper id 41201604IJRAT
 
Paper id 37201524
Paper id 37201524Paper id 37201524
Paper id 37201524IJRAT
 
Paper id 28201432
Paper id 28201432Paper id 28201432
Paper id 28201432IJRAT
 
Paper id 21201488
Paper id 21201488Paper id 21201488
Paper id 21201488IJRAT
 
Paper id 41201621
Paper id 41201621Paper id 41201621
Paper id 41201621IJRAT
 
Paper id 41201613
Paper id 41201613Paper id 41201613
Paper id 41201613IJRAT
 
Paper id 37201505
Paper id 37201505Paper id 37201505
Paper id 37201505IJRAT
 
Paper id 35201501
Paper id 35201501Paper id 35201501
Paper id 35201501IJRAT
 
Paper id 42201622
Paper id 42201622Paper id 42201622
Paper id 42201622IJRAT
 
Paper id 312201523
Paper id 312201523Paper id 312201523
Paper id 312201523IJRAT
 
Paper id 312201522
Paper id 312201522Paper id 312201522
Paper id 312201522IJRAT
 

Destaque (20)

Paper id 35201569
Paper id 35201569Paper id 35201569
Paper id 35201569
 
Paper id 41201606
Paper id 41201606Paper id 41201606
Paper id 41201606
 
Paper id 28201439
Paper id 28201439Paper id 28201439
Paper id 28201439
 
Paper id 37201539
Paper id 37201539Paper id 37201539
Paper id 37201539
 
Paper id 312201534
Paper id 312201534Paper id 312201534
Paper id 312201534
 
Paper id 312201516
Paper id 312201516Paper id 312201516
Paper id 312201516
 
Paper id 24201443
Paper id 24201443Paper id 24201443
Paper id 24201443
 
Paper id 36201532
Paper id 36201532Paper id 36201532
Paper id 36201532
 
Paper id 23201411
Paper id 23201411Paper id 23201411
Paper id 23201411
 
Paper id 41201604
Paper id 41201604Paper id 41201604
Paper id 41201604
 
Paper id 37201524
Paper id 37201524Paper id 37201524
Paper id 37201524
 
Paper id 28201432
Paper id 28201432Paper id 28201432
Paper id 28201432
 
Paper id 21201488
Paper id 21201488Paper id 21201488
Paper id 21201488
 
Paper id 41201621
Paper id 41201621Paper id 41201621
Paper id 41201621
 
Paper id 41201613
Paper id 41201613Paper id 41201613
Paper id 41201613
 
Paper id 37201505
Paper id 37201505Paper id 37201505
Paper id 37201505
 
Paper id 35201501
Paper id 35201501Paper id 35201501
Paper id 35201501
 
Paper id 42201622
Paper id 42201622Paper id 42201622
Paper id 42201622
 
Paper id 312201523
Paper id 312201523Paper id 312201523
Paper id 312201523
 
Paper id 312201522
Paper id 312201522Paper id 312201522
Paper id 312201522
 

Semelhante a Paper id 252014109

IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...
IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...
IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...IRJET Journal
 
“Analysis and design of multi storeyed load bearing reinforced masonry struct...
“Analysis and design of multi storeyed load bearing reinforced masonry struct...“Analysis and design of multi storeyed load bearing reinforced masonry struct...
“Analysis and design of multi storeyed load bearing reinforced masonry struct...eSAT Publishing House
 
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...IRJET Journal
 
Door opening analysis of wind turbine steel tubular tower
Door opening analysis of wind turbine steel tubular towerDoor opening analysis of wind turbine steel tubular tower
Door opening analysis of wind turbine steel tubular towereSAT Publishing House
 
Site selection and building components.pdf
Site selection and building components.pdfSite selection and building components.pdf
Site selection and building components.pdfAJPGaming
 
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...IRJET Journal
 
Paper id 2920143
Paper id 2920143Paper id 2920143
Paper id 2920143IJRAT
 
IRJET- Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...
IRJET-  	  Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...IRJET-  	  Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...
IRJET- Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...IRJET Journal
 
Industrial construction
Industrial constructionIndustrial construction
Industrial constructionCharlie Gupta
 
TECH_SEMINAR_sachith_gowda[1].pptx
TECH_SEMINAR_sachith_gowda[1].pptxTECH_SEMINAR_sachith_gowda[1].pptx
TECH_SEMINAR_sachith_gowda[1].pptxChandanLawrence
 
analysis and design of cold formed steelpurlin.ppt
analysis and design of cold formed steelpurlin.pptanalysis and design of cold formed steelpurlin.ppt
analysis and design of cold formed steelpurlin.pptMacKy29
 
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...IRJET Journal
 
Paper id 2920142
Paper id 2920142Paper id 2920142
Paper id 2920142IJRAT
 
Seismic Response of Structure with Single Core
Seismic Response of Structure with Single CoreSeismic Response of Structure with Single Core
Seismic Response of Structure with Single Coreijtsrd
 
IRJET- Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...
IRJET- 	  Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...IRJET- 	  Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...
IRJET- Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...IRJET Journal
 
A Review on Stressed Skin Behaviour of Steel Façade Frame
A Review on Stressed Skin Behaviour of Steel Façade FrameA Review on Stressed Skin Behaviour of Steel Façade Frame
A Review on Stressed Skin Behaviour of Steel Façade FrameIRJET Journal
 
IRJET- Study of Behaviour of Multi-Storey Building with Shear Walls
IRJET-  	  Study of Behaviour of Multi-Storey Building with Shear WallsIRJET-  	  Study of Behaviour of Multi-Storey Building with Shear Walls
IRJET- Study of Behaviour of Multi-Storey Building with Shear WallsIRJET Journal
 
Use of flat slabs in multi storey commercial building situated in high seismi...
Use of flat slabs in multi storey commercial building situated in high seismi...Use of flat slabs in multi storey commercial building situated in high seismi...
Use of flat slabs in multi storey commercial building situated in high seismi...eSAT Publishing House
 
IRJET- Comparative Study of Tube in Tube Structure and Frame Tube Structure
IRJET- Comparative Study of Tube in Tube Structure and Frame Tube StructureIRJET- Comparative Study of Tube in Tube Structure and Frame Tube Structure
IRJET- Comparative Study of Tube in Tube Structure and Frame Tube StructureIRJET Journal
 

Semelhante a Paper id 252014109 (20)

Roof trusses
Roof trussesRoof trusses
Roof trusses
 
IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...
IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...
IRJET- Analysis of Steel Silos Subjected to Wind Load with Various Slendernes...
 
“Analysis and design of multi storeyed load bearing reinforced masonry struct...
“Analysis and design of multi storeyed load bearing reinforced masonry struct...“Analysis and design of multi storeyed load bearing reinforced masonry struct...
“Analysis and design of multi storeyed load bearing reinforced masonry struct...
 
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...
 
Door opening analysis of wind turbine steel tubular tower
Door opening analysis of wind turbine steel tubular towerDoor opening analysis of wind turbine steel tubular tower
Door opening analysis of wind turbine steel tubular tower
 
Site selection and building components.pdf
Site selection and building components.pdfSite selection and building components.pdf
Site selection and building components.pdf
 
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
 
Paper id 2920143
Paper id 2920143Paper id 2920143
Paper id 2920143
 
IRJET- Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...
IRJET-  	  Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...IRJET-  	  Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...
IRJET- Performance Analysis of Corrugated Steel Plate Shear Wall with Vis...
 
Industrial construction
Industrial constructionIndustrial construction
Industrial construction
 
TECH_SEMINAR_sachith_gowda[1].pptx
TECH_SEMINAR_sachith_gowda[1].pptxTECH_SEMINAR_sachith_gowda[1].pptx
TECH_SEMINAR_sachith_gowda[1].pptx
 
analysis and design of cold formed steelpurlin.ppt
analysis and design of cold formed steelpurlin.pptanalysis and design of cold formed steelpurlin.ppt
analysis and design of cold formed steelpurlin.ppt
 
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
 
Paper id 2920142
Paper id 2920142Paper id 2920142
Paper id 2920142
 
Seismic Response of Structure with Single Core
Seismic Response of Structure with Single CoreSeismic Response of Structure with Single Core
Seismic Response of Structure with Single Core
 
IRJET- Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...
IRJET- 	  Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...IRJET- 	  Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...
IRJET- Seismic Response of Mass and Stiffness Irregular Multi-Storied Stru...
 
A Review on Stressed Skin Behaviour of Steel Façade Frame
A Review on Stressed Skin Behaviour of Steel Façade FrameA Review on Stressed Skin Behaviour of Steel Façade Frame
A Review on Stressed Skin Behaviour of Steel Façade Frame
 
IRJET- Study of Behaviour of Multi-Storey Building with Shear Walls
IRJET-  	  Study of Behaviour of Multi-Storey Building with Shear WallsIRJET-  	  Study of Behaviour of Multi-Storey Building with Shear Walls
IRJET- Study of Behaviour of Multi-Storey Building with Shear Walls
 
Use of flat slabs in multi storey commercial building situated in high seismi...
Use of flat slabs in multi storey commercial building situated in high seismi...Use of flat slabs in multi storey commercial building situated in high seismi...
Use of flat slabs in multi storey commercial building situated in high seismi...
 
IRJET- Comparative Study of Tube in Tube Structure and Frame Tube Structure
IRJET- Comparative Study of Tube in Tube Structure and Frame Tube StructureIRJET- Comparative Study of Tube in Tube Structure and Frame Tube Structure
IRJET- Comparative Study of Tube in Tube Structure and Frame Tube Structure
 

Mais de IJRAT

96202108
9620210896202108
96202108IJRAT
 
97202107
9720210797202107
97202107IJRAT
 
93202101
9320210193202101
93202101IJRAT
 
92202102
9220210292202102
92202102IJRAT
 
91202104
9120210491202104
91202104IJRAT
 
87202003
8720200387202003
87202003IJRAT
 
87202001
8720200187202001
87202001IJRAT
 
86202013
8620201386202013
86202013IJRAT
 
86202008
8620200886202008
86202008IJRAT
 
86202005
8620200586202005
86202005IJRAT
 
86202004
8620200486202004
86202004IJRAT
 
85202026
8520202685202026
85202026IJRAT
 
711201940
711201940711201940
711201940IJRAT
 
711201939
711201939711201939
711201939IJRAT
 
711201935
711201935711201935
711201935IJRAT
 
711201927
711201927711201927
711201927IJRAT
 
711201905
711201905711201905
711201905IJRAT
 
710201947
710201947710201947
710201947IJRAT
 
712201907
712201907712201907
712201907IJRAT
 
712201903
712201903712201903
712201903IJRAT
 

Mais de IJRAT (20)

96202108
9620210896202108
96202108
 
97202107
9720210797202107
97202107
 
93202101
9320210193202101
93202101
 
92202102
9220210292202102
92202102
 
91202104
9120210491202104
91202104
 
87202003
8720200387202003
87202003
 
87202001
8720200187202001
87202001
 
86202013
8620201386202013
86202013
 
86202008
8620200886202008
86202008
 
86202005
8620200586202005
86202005
 
86202004
8620200486202004
86202004
 
85202026
8520202685202026
85202026
 
711201940
711201940711201940
711201940
 
711201939
711201939711201939
711201939
 
711201935
711201935711201935
711201935
 
711201927
711201927711201927
711201927
 
711201905
711201905711201905
711201905
 
710201947
710201947710201947
710201947
 
712201907
712201907712201907
712201907
 
712201903
712201903712201903
712201903
 

Paper id 252014109

  • 1. International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 E-ISSN: 2321-9637 271 Review Paper on Comparison of Conventional Steel Building & Pre-Engineering Building Sagar Wankhade1, Prof. Dr. P. S. Pajgade2 Department of Civil Engineering1, 2, 3, 4, Affiliation name1, 2, 3, 4 Email: sagarwankhade01@gmail.com1 , ppajgade@gmail.com2 Abstract-Pre-Engineered Building (PEB) concept is a new conception of single storey industrial building construction. This methodology is versatile not only due to its quality pre-designing and prefabrication, but also due to its light weight and economical construction. This concept has many advantages over the Conventional Steel Building (CSB) concept of buildings with roof truss. This paper is a comparative study of PEB concept and CSB concept. Index Terms- Industrial steel building, Pre-Engineering Building, IS 875:1987 (LSM) 1. INTRODUCTION An industrial building is any structure that is used to store raw materials, house a manufacturing process, or store the furnished goods from a manufacturing process. Industrial buildings can range from the simplest warehouse type structure to highly sophisticated structures integrated with a manufacturing system. These buildings are low rise steel structures characterised by low height, lack of interior floor, walls, and partitions. The roofing system for such a building is a truss with roof covering. Design of basic elements of the structure (Roof deck, Purlins, Girders, Columns and Girts) is not difficult, but combining them into functional and cost effective system is a complex task. In Industrial building structures, The walls can be formed of steel columns with cladding which may be of profiled or plain sheets, GI sheets, precast concrete, or masonry. The wall must be adequately strong to resist the lateral force due to wind or earthquake. COMPONENT OF AN INDUSTRIAL BUILDING:- The elements of industrial buildings are listed below. 1) Purlins 2) Sag rods 3) Principal Rafters 4) Roof Truss 5) Gantry Girders 6) Bracket 7) Column and Column base 8) Girt Rods 9) Bracings Fig 1: Various component of Industrial building The previous elements are briefly explained below. Purlins Purlins are beams which are provided over trusses to support roof coverings. Purlins spans between top chord of two adjacent roof trusses. When purlin supports the sheeting and rests on rafter then the purlins are placed over panel point of trusses. Purlins can be designed as simple, continuous, or cantilever beams. Purlins are often designed for normal component of forces. the various sections of purlins are as follows. Fig2: Sections of Purlins Sag Rod These are round sections rods and are fastened to the web or purlin. The roof covering in industrial
  • 2. International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 E-ISSN: 2321-9637 272 buildings are not rigid and do not provide proper support. Therefore, sag rods provided between adjacent purlins to extend lateral support for purlins in their weaker direction. A sag rod is designed as a tension member to resist the tangential component of the resultant of the roof load and purlin dead load. The tangential component of the roof load is considered to be acting on the top flange of purlins, whereas the normal component and purlin dead load is assumed to act at its centroid. Therefore the sag rod should be placed at a point where the resultant of these forces act. Fig 3: Sag rod Principal rafter The top chord member of a roof truss is called as principal rafter. They mainly carry compression but they may be subjected to bending if purlins are not provided at panel points. Roof Trusses Roof trusses are elements of the structure. The members are subjected to direct stresses. Truss members are subjected to direct tension and direct compression. Gantry Girder Gantry girders are designed as laterally unsupported beams. Overhead travelling cranes are used in industrial buildings to lift and transport heavy jobs, machines, and so on, from one place to another. They may be manually operated or electrically operated overhead travelling crane. A crane consists of a bridge made up of two truss girders which moves in the longitudinal direction. To facilitate movement, wheels are attached to the ends of crane girders. These wheels move over rails placed centrally over the girders which are called gantry girders. Fig 4: Gantry Girder Brackets Brackets types of connections are made whenever two members to be secured together do not intersect. Fig 5: Brackets Column and Column Base A column is a structural member which is straight to two equal and opposite compressive forces applied at the ends. Stability plays an important role in the design of compression member because in columns buckling is involved. The problem of determining the column load distribution in an industrial building column is statically indeterminate. To simplify the analysis the column is isolated from the space frame and is analyzed as a column subjected to axial load and bending. An industrial building column is subjected to following loads in addition to its self weight. 1) Dead load from truss 2) Live load on roof truss 3) Crane load 4) Load due to wind Steel columns are normally supported over concrete blocks. However when the load supported by these columns are large and the bearing pressure of concrete from below is insufficient to resist the loads, they may fail. Therefore it is a normal practice to distribute column loads to steel base plate which are placed over these concrete blocks. In addition to transferring safely the column loads, a base plate also maintains the alignment of the column in plane, verticality of the column and controls column and frame deflection.
  • 3. International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 E-ISSN: 2321-9637 273 Fig 6: Column and column base Girt These are beams subjected to unsymmetrical bending. These support vertical dead load from the sliding and horizontal wind loads. Usually these are unequal angle sections connected with the longer leg to withstand the effect of wind. Girts are assumed to be continuous. Bracing It is important to trace the longitudinal crane forces through the structure in order to insure proper wall and crane bracing. For lightly loaded cranes, wind bracing in the plane of the wall may be adequate for resisting longitudinal crane forces. While for every large longitudinal forces, the bracing is most likely to be required in the plane of crane rail. When the wind acts in the direction normal to the plane of industrial building bents, i.e., in the longitudinal direction, then it becomes essential to brace it to another to provide sufficient stability against wind or other longitudinal force. Vertical column bracing transfers the longitudinal force to the foundation. Fig 7: Bracing 2. VARIOUS LOADS ON AN INDUSTRIAL BUILDING Dead load The dead load of truss includes the dead load of roofing materials, purlins, trusses and roof bracing systems. The dead weight of the trusses may be assumed to be equal to 10% of the load on the truss. The weight of the bracing may be assumed to be 12- 15 N/m2 of the plan area. A simple for the estimation of the approximate dead weight of the roof truss in N/m2. Superimposed loads The load assumed to be produced by the intended use of occupancy of a building, including the self weight of movable partitions, distributed, concentrated loads, loads due to impact and vibration sand dust load but excluding wind, seismic, snow and other loads due to temperature changes, creep, shrinkage, differential settlement etc IS: 875 (part 2) 1987 specifies live loads to be assumed in the analysis of an industrial building. Wind load The most critical load on an industrial building is the wind load. For the roof and walls of an industrial building, consideration must be made for pressure difference between the opposite faces of such elements to accounts for external and internal air pressures exerted by wind blowing against the building. When the negative air pressure is less than the atmospheric pressure is known as suction. IS 875 (part 3) 1987 specifies the following wind load coefficients to be assumed in the analysis of an industrial building. The wind force F is obtained by an equation F= (Cpe – Cpi ) APz Snow load IS 875 (part 4) 1987 specifies the following snow load to be assumed in the analysis of an Industrial building. If the structure is situated in an area where the roof is subjected to snow, the load considered for design should be the maximum of live or snow load. The load due to snow depends upon the pitch of the roof, shape of the roof and roofing material. Snow load may be assumed to be 2.5 N/m2 per mm depth of snow. When the roof slope is greater than 50 degree Snow load may be neglected. 3. AN OVERVIEW OF THE CONCEPT OF PRE -ENGINEERING BUILDINGS The scientific-sounding term pre-engineered buildings came into being in the 1960s. The buildings were pre-engineered because they rely upon standard engineering designs for limited number configurations. These buildings are mostly custom designed metal building to fill the particular needs of customer. Basically, a PEB is a rigid jointed plane frame from hot-rolled or cold – rolled sections, supporting the roofing and side cladding via hot-rolled or cold-formed purlins and sheeting rails. Pre Engineered Buildings offers many advantage such as more effective use of steel than in simple beams, easy extension at any time in the future and ability to
  • 4. International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 E-ISSN: 2321-9637 274 support heavy concentrated loads. PEB frames have a roof slope of from 6 to 12 degree, mainly chosen because of the smaller volume of air involved in heating and cooling the building. Usually, the portal frames are composed of tapered stanchions and rafters. Most often, the beam is tapered by providing a slope to the flange for water runoff and keeping the bottom flange horizontal for ceiling applications. The main reason for the popularity of the gabled rigid- frame system lies in its cost efficiency. It requires less metal than most other structural systems of the same span and eave height. A typical single-storey metal building system is supported by main frames forming a number of bays. Bay size is the space between frame centerlines measured along the sidewall. Frame clear span is the clear distance between frame columns. Metal building system can have a variety of wall materials, the original and still the most popular being metal siding, supported by sidewall or end wall girts. Fig 8: Various component of PEB 4. COMPONENT OF A PRE-ENGINEERED BUILDING The component of a PEB may be broadly divided into following four parts, namely 1) Main Frame 2) Secondary Frame 3) Wind Bracing 4) Exterior cladding Main Frame Moment resisting frames provides lateral stability and transfer the roof and wall load to the foundation through anchor bolts. Main frames are built up tapered or constant depth column and rafters. The tapered profile is based on the moment diagram of the structure, which results in greater economy compare to any other structure. This is the main difference with respect to other structural steel frame building where in straight columns and beams are used. The tapered sections are welded using automatic welding machine to ensure high quality and rapid construction. Flanges are welded to the web by a continuous single side fillet weld. Splices using flange plate are usually provided at the zones of low moment in the frame. Secondary Frame Purlins girts and eves struts are secondary structural members used to support the wall and roof panels. Purlins are used on the roof, girts are used on the walls and eave struts are used at the intersection of the sidewall and the roof. Purlins and Girts provide lateral bracing to the building columns, rafter and prevents lateral buckling of compression flanges. Purlins and Girts are usually Cold Rolled steel C or Z sections having minimum yield strength of 345 Mpa. Z shaped purlins are usually adopted for PEB since this shape provides greater advantage of being lapped at support points and nested together to increase the stiffness. C section on the other hand lacks this capability. Wind Bracing Roof and wall cross bracing provide longitudinal stability to the building. It enables effective transfer of wind load acting on building end walls to the foundation. Exterior Cladding Exterior Cladding provides a water tight envelope. It transfers the Structural loads i.e. Wind and Live load to the Secondary Framing. It provides lateral bracing to the Purlin and girt. 5. STABILITY OF A PRE-ENGINEERED BUILDING A building lacking lateral stability against wind and earthquake loads will not be standing for long. The most popular Pre-Engineered structure, rigid frame, relies on its own moment resisting ability to laterally support the building. A typical design solution for metal building systems is to provide moment- resisting frames spanning the short direction of the building and braced frames in the exterior walls. The vertical bracing located in the end wall acts primarily in resisting lateral loads acting in the direction parallel to the frames, while the sidewall bracing resists the loads in trhe perpendicular direction. 6. COMPARISON OF PRE-ENGINEERED STEEL BUILDINGS OVER CONVENTIONAL STEEL BUILDINGS PRE-ENGINEERED STEEL BUILDINGS CONVENTIO NAL STEEL BUILDINGS Structure Weight Pre-engineered buildings are on an average 30% lighter through efficient use of steel. Primary members are tapered built up sections, with large depths in the ares of highest stress. Primary steel members are selected from standard hot rolled I section, which are, in many segments of the members, heavier than what is actually required by
  • 5. International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 E-ISSN: 2321-9637 275 design. Members have constant cross-sections regardless of the varying magnitude of the local stresses along the member length. Design Specialized computer analysis and dedign programs optimize material required. Drafting is also computerized using standard details that minimize use of project custom details. Substantial engineering and detailing work is required on every project. Generalized computer analysis programs requires extensive input/output and design alterations. Delivery Average 6 to 8 weeks. Average 20 to 26 weeks. Foundations Simple design, easy to construct and light weight. Extensive, havy foundations required. Erection Simplicity Since the connections of the components are standard, the learning curve of erection for each subsequent project is faster. The connections are normally complicated and differ from project to project, resulting in longer learning curves of erection for new project. Erection Cost & Time Both costs and time of erection are accurately known based upon extensive experience with similar buildings. Typically conventioonal steel buildings are 20% more expensive than PEB. In most of the cases the erection cost and time arenot estimated accurately. Seismic Resistance The low-weight flexible frames offer higher resistance to seismic force. Rigid heavy weight structures do not perform well in seisnic zones. Overall price Price per square meter may be as much as 30% lower than conventional building. Higher price per square meter. Architecture Outstanding architectural design can be achieved at low cost using standard architectural features and interface details Special architectural design and features must be developed for each project, which often require research and resuls in higher cost. Future Expansion All project records are safely and orderly kept in electronic format indefinitely, making it easier for owner or designer to obtain a copy of his building records at any time. It would be difficult to obtain records, after a long period of time. It is required to contact more than one party, involved in project, to obtain accurate information. Safety and responsibilitie s Single source of supply results in total responsibility by one supplier, including design liability. Multiple responsibilities can result in question of who is responsible when components do not fit properly, insufficient material is supplied, or materials fail to perform. Performance All components have been specified and designed specifically to act together as asystem for maximum efficiency, precise fit and peak performance in the field. Components are custom designed for specific application on a specific job. Design and detailing errors are possible when assembling the diverse compoments in unique building. 7. ADVANTAGES OF STEEL CONSTRUCTION 1. High quality, aesthetic 2. Lower maintenance costs
  • 6. International Journal of Research in Advent Technology, Vol.2, No.5, May 2014 E-ISSN: 2321-9637 276 3. Non combustible to fire 4. Steel is environmentally friendly 5. Components can be used again and again 6. Steel components are frequently functional 7. Steel construction is strong, durable and stable 8. Steel Construction promotes good design and safety 9. Construction with Steel is sustainable to Temperature effects 10. Steel frame construction is rigid in structure and dimensionally stable 11. Steel can be re-used without effecting the environment 12. Construction with Steel components is very fast compared to other materials 13. Steel construction of buildings with steel components is resistant to termites and other destructive insects. 14. Steel constructions are cheaper than any other construction methods 15. Steel construction is a fast method of construction 8. APPLICATION OF PEB The most common applications of Pre-Engineered Buildings are: 1) Factories 2) Steel Mills 3) Sports Stadiums 4) Shipyards 5) Logistic Centres 6) Waste Treatment Factories Fig 9: Logistic centre Fig 10: Shipyards CONCLUSION This paper effectively conveys that PEB structures can be easily designed by simple design procedures in accordance with country standards. In light of the study, it can be concluded that PEB structures are more advantageous than CSB structures in terms of cost effectiveness, quality control speed in construction and simplicity in erection. The paper also imparts simple and economical ideas on preliminary design concepts of PEBs. The concept depicted is helpful in understanding the design procedure of PEB concept. REFERENCES [1] International Journal of Engineering Sciences & Emerging Technologies, June 2013. ISSN: 2231 – 6604 Volume 5, Issue 2, pp: 75-82 [2] Syed Firoz, Sarath Chandra Kumar B, S.Kanakambara Rao, Design Concept Of Pre Engineered Building, International Journal of Engineering Research and Applications (IJERA) Vol. 2, Issue 2,Mar-Apr 2012, pp.267-272. [3] Dr. N. Subramanian Computer Design Consultants Gaithersburg, MD 20878, USA Pre- Engineered Buildings Selection of Framing System, Roofing & Wall Materials [4] Dr. V. L. Shah & Prof. Mrs Vina Gore, Limit state Design of Steel Structure [5] S. K. Duggal, Limit State Design of Steel Structure.