2. Economic alternative
The Adatto hospital bed is an economically sound
alternative. Adatto has 4-sectional mattress base
and it comes with a wide range of assemblies and
options. Other Merivaara bed accessories are
compatible with Adatto.
Due to its adaptability, wide range of accessories and excellent handling,
Adatto is suitable for use from long-term wards to ICU wards. Adatto’s
modularity allows it to be adapted to suit any need.
Adatto’s 4-sectional mattress base is easy to keep
clean. The perforated, bubble-like base structure en-
sures air circulation between the bed and mattress.
Design castors, Ø 150 mm or Ø 125 mm.
Central locking system. The bed can be extended with 20 cm Mini-ACP limiter 10000 1099
adjustable bed end and extension Battery series 10000 1091
PJP castors, Ø 125 mm.
board. The extendable bed end fits all
Central locking system.
models.
Individual locking castors, Ø 125 mm. Extension board: 80 cm 10000 0718
90 cm 10000 0728
3. The grab handle is a safe and ergonomic patient assistance device, which is suitable for use with most patients. The
grab handle enhances patient self-initiative. The unique fixing of grab handle does not widen the bed, thus allowing it
to fit easily through doors and into elevators.
4. Excellent treatment capabilities
Correct, variable treatment positions are of the utmost importance for patient
well-being. Studies show that a versatile use of bed adjustments considerably
reduces pressure on the skin and activates and rehabilitates the patient.
The multiple positions of the Adatto bed can be easily adjusted using a hand
controller. The sliding and rising adjustment of the back section combined with
the leg angle adjustment keeps the patient’s centre of gravity firmly in place.
The skin is not stretched, and the risk of pressure sores forming reduces sig-
nificantly. According to studies, there is up to 90% less shifting in the centre of
gravity compared to two and three-sectional beds.
The Adatto hospital bed’s range of adjustments is truly extensive. The mattress
base is also easily extended using an adjustable foot end and extension board.
Adatto is a tool, which is designed to facilitate nursing work. Adatto’s lightness
and ease of use make patient transfers and supporting treatment positions
easy, while reducing back strain on the nursing staff.
The position of the
Adatto mattress base
(40° back angle, 35° hip
angle, knee angle in up-
per position) has been
proven to evenly distri-
bute pressure on the
skin for patients of diffe-
rent sizes. The position is
especially recommended for
long-term bed care.
Measurement results for the distribution of pressure on the skin
Adatto bed with Nova Sensiva mattress Two-sectional bed with basic mattress
• 40° back angle • 40° back angle
• 35° hip angle • 0° hip angle
• knee angle in upper position Average pressure: 56.2 mmHg
Average pressure: 4.22 mmHg Maximum pressure: 200 mmHg
Maximum pressure: 20.0 mmHg
5. The cardiac chair position is the recommended The Fowler position with knee angle adjustment distributes even-
resting position for many different patient groups. ly pressure on the skin and relieves swelling
in the lower extremities.
The electrically-adjusted back section has a sliding, The Psoas position relaxes the back and
conforming movement. relieves swelling in the lower extremities.
The CPR position can be quickly adjusted This position combines back angle
using the manual Trendelenburg handle. and Trendelenburg adjustments.
6. Functional design
and colour options
Special attention was given to functional ergonomics and
patient comfort in designing the Adatto hospital bed. The
bed has user-friendly handling surfaces and its colour range
has been carefully selected. The bed and its accessories are
visually compatible with other Merivaara products.
Silent and practical functions together with the extensive
range of accessories support daily nursing tasks and impro-
ve patient comfort.
Medium subframe
with accessories
Design ends, fixed to the frame model, Adjustable design end, mounted on mattress base Basic end, fixed to the frame
mounted in subframe holes. frame tubing. Adjustable length: + 20 cm. model, mounted on subframe
80 cm............ 10000 9890 white 80 cm.......... 10000 9880 white adapters.
10000 9892 light blue 10000 9882 light blue 80 cm....... 10000 9870 white
10000 9898 blue 10000 9888 blue 10000 9871 grey
90 cm............ 10000 9990 white 90 cm.......... 10000 9980 white 10000 9874 beech
10000 9992 light blue 10000 9982 light blue 90 cm....... 10000 9970 white
10000 9998 blue 10000 9988 blue 10000 9971 grey
10000 9974 beech
8. Accessories
Adatto’s extensive selection of
accessories are ergonomical
and support the patient reha-
bilation.
Grab handle
10000 9755
Lifting pole, with standard Lifting pole, with roll-up IV rod, 4 hooks IV rod, 2 hooks IV rod, 4 hooks,
triangle 10000 9774 triangle 10000 9776 10000 0499 12800 9720 angled shaft 10000 9778
Monitor / journal tray Monitor / journal tray (writing position) Patient journal basket
12800 9768 12800 9768 10000 0784 (pictured) or 12800 9784
Urine bottle holder Utility basket, baseframe mount Nametag holder
12800 9790 (only for 90 cm beds) 12800 9783 10000 0798
9. Merivaara quality
Merivaara hospital furnishings are designed, manufactured and
delivered in accordance with individualised Quality Management
System Standard ISO 9001:2000. The Environmental Management
System of Merivaara is certified according to ISO 14001:1996 stan-
dard. Having been in operation since 1901, Merivaara can guaran-
tee the customer that its products are functional and safe.
Best for the patient, best for the nurse. For one hundred years.
10. Light and handy hospital bed
TECHNICAL SPECIFICATIONS
• frame: epoxy coated steel; several colour options
• mattress base: 4-sectional, specially-contoured
plates in ABS plastic
• height adjustment mechanism: epoxy coated steel
• castors: Ø 125 mm or 150 mm, central braking
system, with a directional castor
• bumper rollers on mattress base corners
DIMENSIONS
Medium subframe adjustments (electrically operated) • overall length: 2156 mm (Scandinavian model)
(medium subframe) or 2237 mm (long subframe)
• bed width: 830 mm or 930 mm
• overall width: 885 or 985 mm with side rails mounted
• recommended mattress size: 750 x 2000 mm or 850 x 2000 mm
• weight: approx.100 kg without accessories
• maximum load: 225 kg with equipment
ADJUSTMENTS
• mattress base height adjustment: 415 – 780 mm
hydraulically or 445 – 810 mm electrically operated
• back section: electrically operated or gas spring-assisted,
ergonomically sliding and rising movement
• thigh section: electrically operated or gas spring assisted
• calf section: manually operated (gas spring assisted)
• Trendelenburg (26º) and anti-Trendelenburg (7º)
adjustments manually operated (gas spring assisted)
Long subframe adjustments (electrically operated) ACCESSORIES AND OPTIONS
Extensive selection of accessories and colour/design options
• various bed end models and colour options
• frame colour options
• castors Ø 125 and 150 mm
• side rails (different models)
• grab handle
• lifting poles
• IV rods Rights to model and structural changes reserved.
• monitor / journal tray
• various utility baskets
Trendelenburg and anti-Trendelenburg adjustments • urine bottle holder
• mini-ACP limiter
• battery series
3-year guarantee
Taktum/Markprint 6/2004 1000 3/1
Merivaara Corp.
Puustellintie 2, FI-15150 LAHTI, FINLAND
Tel. +358 3 3394 611 • Fax +358 3 3394 6144
merivaara@merivaara.fi
www.merivaara.com