12. Universal Basic Module
Assembly Power jumper contacts on the field side
Fine modularity for the assembly on
the rail . . .
. . . secure connection with dovetails
Quick exchange of an I/O module. . .
. . . within the assembly – without tool
Exchange within the assembly
Data contacts
Safe, automatic connection by tinned, self-cleaning slide contact, ground (earth)
contact makes first and breaks last (Series 750 and 753)
Safe, automatic connection by gold-plated, self-cleaning slide contacts
with high contact safety (750 and 753 Series)
I/O Module
WAGO-I/O-SYSTEM 750
W x H* x L (mm) 12 x 65 x 100
* from upper-edge of carrier rail
W
H
L
10
1
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
14. With Pluggable Connector
I/O Module
CAGE CLAMP®
connection
Vibration-proof, fast and maintenance-free
wiring of 0.08 mm2
- 2.5 mm2
/ AWG 28 - 14
To remove the connector
Locate the orange pull-tab on the connector ...
Alternatively, a standard screwdriver can be used to
remove the connector from the I/O module.
... the connector is automatically disengaged.
... pull toward the front of the connector ...
Removal from the assembly
... removal from the assembly - without tool.Assembly on the rail ...
WAGO-I/O-SYSTEM 753
W x H* x L (mm) 12 x 65 x 100
* from upper-edge of carrier rail
W
H
L
W
1
12
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
42. 1
40
MODBUS/TCP
MODBUS-RTU
Depending on the application, PLCs can be selected for various protocols.
The wide variety of controllers available for the main fieldbus systems and
industrial Ethernet standards enables the I/O system to easily accommodate
individual customer requirements without major modifications.
These factors minimize handling errors and ensure the long-term protection of
system investments.
PLC - Industrial Compact PC / PLC - Programmable Fieldbus Controller
LINUX®
IEC 60870-5-101/-104
IEC 61850
IEC 61400-25
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
94. WAGO BACnet Configurator
WAGO BACnet Configurator
The WAGO BACnet Configurator is an independent commissioning,
configuration and management software.
The configurator fully supports BACnet-specific functions of the
WAGO 750-830 BACnet/IP Controller.
The configurator creates and configures WAGO BACnet/IP
BACnet objects. Import and export functions allow further processing
of configuration data.
For integration into existing BACnet/IP networks, the BACnet
devices available can be scanned, displayed in a browser and
data exchange can be implemented for WAGO devices.
Among the configurator’s additional capabilities are the logical
structuring of the project and network, addressing of the controller
and configuration of client and server in every WAGO BACnet/IP
controller.
The representation of the devices, objects and configuration data is
done in a logical, structured network and browser view.
Description
Depending on the function used, both online and offline operation is
possible.
The configurator displays all configuration data. The user may
change the data, load it onto either one, or several, controllers and
save it as a project.
The configurator provides a browser to view the BACnet object
properties and modify the current parameters (communicate value
changes, write property values, utilize BACnet services, etc.).
services.
System requirements:
Operating system: Windows®
2000,
Windows®
Windows®
Vista
WAGO BACnet Configurator can be downloaded for free at:
www.wago.com
1
92
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
298. 1
296
Safe I/O for PROFIBUS and PROFINET
with the WAGO-I/O-SYSTEM 750/753
The WAGO-I/O-SYSTEM 750/753 PROFIsafe modules are safe
digital inputs and outputs in accordance with IEC 61508.
They are designed for use with PROFIBUS using the PROFIsafe
protocol. Additionally, the safe modules do not require major
modifications to existing 750 Series nodes for use. PROFIsafe is a
protocol for safe communication, and is certified in accordance with
IEC 61784-3-3.
Both safety and non-safety I/O modules can co-exist on the same
node, allowing safety sensors and actuators to be monitored and
controlled locally.
Logic operations are performed using a fail-safe PLC with PROFIBUS or
PROFINET interface as based on the PROFIsafe safety protocol.
Evaluation of the input data, as well as the output of the safe status
signals via output modules, are controlled by the fail-safe PLC/control.
The modules are configured via GSD file in accordance with GSD
specification V4.
This makes it possible to implement safety applications up to:
- CAT. 4 and PLe according to EN 13849
- SIL 3 based on EN 62061
The functionality of the 753 Series modules can be adjusted via safety
parameters.
The following I/O have been approved for use with the
modules:
- 750-333 and 750-343 PROFIBUS Couplers
- 750-833 PROFIBUS Controller
- 750-340 and 750-370 PROFINET Couplers
The required firmware version and assembly guidelines can be found in
the product manual for each device.
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
306. 1
304
Fieldbus Technology for Use in Hazardous Areas
(Gas, Dust and Mining)
Today's development shows that many chemical or petrochemical
companies have production plants, production and process
automation machines in operation which use gas-air or dust-air
mixtures which can be explosive. For this reason, the electrical
components used in such plants and systems must not pose a risk of
explosion resulting in injury to persons or damage to property.
The WAGO-I/O-SYSTEM 750 is designed for use in both
hazardous and non-hazardous environments.
Using the fieldbus technology in hazardous environments can be
time consuming and cost intensive and is only made possible in a
limited way.
When used in hazardous areas of Zone 2, the
WAGO-I/O-SYSTEM 750 offers a safe, easy and economical
connection to the sensors and actuators of Zones 0 and 1.
The Ex i I/O modules were specially developed for this
purpose. They build up an intrinsically safe section, which can be
integrated into a standard fieldbus node, offering all the
advantages of a state-of-the-art fieldbus technology (e.g., fieldbus
independency, flexibility, modularity,
programmability, reliability, cost effectiveness).
The WAGO-I/O-SYSTEM 750 is also approved for mining
applications.
Additional information at www.wago.com:
Fieldbus Technology for Use in Hazardous Areas
NAMUR
HART
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
350. 1
348
WAGO-I/O-SYSTEM 750
for an Extended Temperature Range from -20 °C to +60 °C
WAGO-I/O-SYSTEM 750
The standard operating temperature range for most industrial
applications is 0°C to 55°C, and WAGO offers a full line of
industrial I/O modules to meet these applications. However, some
applications require that components operate in environments outside
this temperature range; e.g., the monitoring and controlling of rail track
heaters, or the lighting control in open-air building such as railway
stations.
For these applications, WAGO now offers a line of
WAGO-I/O-SYSTEM products for temperatures ranging from -20°C to
+60°C. Key to WAGO's extended-temperature products are the
continuous enhancement of design and materials, use of coated PCBs
and highly accurate production methods.
+ 60 °C60 °C
+ 40 °C
+ 20 °C
+ 10 °C
0 °C
- 5 °C
-10 °C
-15 °C
-20 °C
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
352. 1
350
To easily perform cost-effective, centralized deactivation of
complete actuator groups safely, the actuator‘s power supply can
be switched off using a safety switching device. This can either
be performed for each individual actuator or by turning off the
power supply to a group of control outputs.
Ensure that, in the event of failure, no interferences from other
current or power circuits will occur even when the control voltage
is switched off so the defined safety function properties (logic and
time response) remain unchanged.
WAGO 75x-yyy/zzz-8zz I/O Modules are designed to provide
“interference-free“ safety functionality.
These modules comply with safety requirements up to Category 4
of DIN EN ISO 13847-1:2007.
Safety category and performance level depend solely on the sa-
fety components and their wiring. “Interference-free“ WAGO I/O
modules have no active influence on the safety function, they are
not an active part of the safety application and are not a substitu-
te for the safety switching device! When using the components in
safety functions, the corresponding notes must be observed in the
relevant manual!
Use of Interference-Free I/O Modules in Safety Applications
When using the digital output modules in safety-related applications, the modules belonging to a safety switching device shall be
combined to form a potential group.
The voltage for the potential group shall only be supplied via 750-601/750-602 Supply Modules or 750-626 Filter Module.
Either a power supply module or a separation module without power jumper contacts (750-616) must be connected at the end of the
potential group.
1 4
2 5
3 6
24 V
0 V
PE
4 8
3 7
2 6
1 5
D01 D02
24 V
0 V
PE
4 8
3 7
2 6
1 5
D01 D02
24 V
0 V
PE
1 4
2 5
3 6
24 V
0 V
PE 750-616
4 8
3 7
2 6
1 5
D01 D02
24 V
0 V
D03 D04
4 8
3 7
2 6
1 5
D01 D02
24 V
0 V
D03 D04
Safety switch module/
Safety module
Supply module
Output modules
in safety related applications
Supply
module or
Separation
module
Potential group
for safety related applications
Additional potential
groups
Item description for interference-free I/O modules
750-501/000-800 2DO 24V DC 0.5A/Interference-free
750-502/000-800 2DO 24V DC 2.0A/Interference-free
750-504/000-800 4DO 24V DC 0.5A/Interference-free
750-504/025-800 4DO 24V DC 0.5A/T/Interference-free
750-506/000-800 2DO 24V DC 0.5A/Diagnostics/Interference-free
750-508/000-800 2DO 24V DC 2.0A/Diagnostics/Interference-free
750-531/000-800 4DO 24V DC 0.5A/2-conductor/Interference-free
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
478. 4
476
WAGO-I/O-SYSTEM 757
Illustration: Sensor / Actuator boxes with spacer module
Sensor / Actuator Boxes
WAGO´s IP67 Sensor/Actuator Boxes collect signals local to the
machine. This allows signals to be collected and transmitted to the
WAGO-I/O-SYSTEM 750 in harsh industrial environments where direct
operation is impossible.
The 757 Series is available in two versions. The M16/M23 connector
version is ideal when the system or machines need to be transported or
a quick disconnection is required during servicing (e.g., defective
cable). The pre-cabled version is best suited for applications where
difficult cable routing makes it impossible to lay cables equipped with
connectors or where it is difficult to make precise cable routing.
WAGO's sensor/actuator boxes have an extremely compact, robust
design, and meet IP67 protection standards. The pre-cable boxes even
comply with IP68 requirements (1 meter water depth for 72 hours).
Furthermore, adjacent boxes can be clipped to one another using
spacer modules, allowing for safe, easy installation and maintenance
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
sales@electromate.com
Sold & Serviced By:
496. 5
494
WAGO-I/O-SYSTEM 756
WAGO-I/O-SYSTEM 756
IP67 Cables and Connectors
Series 756 offers a wide range of accessories for the connection of
inductive or capacitive proximity switches, light barriers, flow control
devices, push buttons etc. to the WAGO-I/O-SYSTEMS 751
(IP67 AS-Interface), 755 (IP67 fieldbus technology), 757 (IP67
sensor/actuator boxes) and WAGO-Speedway 767 (modular IO
system IP67). The cables are not only a protection against dust and
water, the design of their coupling nuts also provides protectionagainst
mechanical loosening when exposed to vibrations. In addition to that,
fixed cables offer bend protection.
Cables with one or two preassembled wire ends are used.
Cables with one preassembled wire end are often used when the
length of the cable cannot be predetermined exactly or when the
cable assembly with connectors proves to be difficult. Cables with one
free wire end can therefore be adapted to individual prerequisites.
Cables with two preassembled wire ends drastically reduce assembly
and installation time.
ELECTROMATE