2. At a glance….At a glance….
• Definition
• Features
• Construction
• Working
Principle
• Application
• Conclusion
3. Brief idea about I/PBrief idea about I/P
converter…converter…
A “current to pressure” converter (I/P) converts an analog signal (4 to 20 mAA “current to pressure” converter (I/P) converts an analog signal (4 to 20 mA
DC) to a proportional linear pneumatic output (3 to 15 psig). Its purpose is toDC) to a proportional linear pneumatic output (3 to 15 psig). Its purpose is to
translate the analog output from a control system into a precise, repeatabletranslate the analog output from a control system into a precise, repeatable
pressure value to control pneumatic actuators/operators, pneumatic valves,pressure value to control pneumatic actuators/operators, pneumatic valves,
dampers, vanes etc.dampers, vanes etc.
Loop Power is high.Loop Power is high.
It is ideal for Pneumatic Control Systems.It is ideal for Pneumatic Control Systems.
It is need to zero and Span Adjustments for Field Calibration.It is need to zero and Span Adjustments for Field Calibration.
It is rugged Zinc Cast Housing.It is rugged Zinc Cast Housing.
4. o Features of I/P Converter…Features of I/P Converter…
Table mounted set-up.
Compact and simple to operate.
Digital calibrator.
Combined set up for study of I/P and P/I
converter.
Specifications
Pressure Transmitter Type Two wire, Range 0–1 bar, Output 4–20 mA
I/P converter Input 4-20mA, Output 3-15 psig
Signal Isolator Input: 4 to 20mA, output 4-20mA
Digital Calibrator Measure/source, milliamp/millivolt mode
Air regulator Range 0-2.5 kg/cm2
Air filter regulator Range 0-2.5 kg/cm2
Pressure gauge Range 0-2.5 kg/cm2(2No), Range 0-7 kg/cm2(1Nos)
Overall dimensions 550Wx300Dx400H mm
Optional Mini compressor.
6. ◊ Working
Principle :-
•External 24 VDC 230 +/- 10 VAC, 50 Hz, 1 phase
power supply & Clean, oil & moisture free air, pressure 2
Bar, consumption 50 LPH air supply required.
•Converts an analog signal (4 to 20 mA)to a proportional
linear pneumatic output (3 to 15 psig).
•Electromagnetic force balance deliver consistently high
performance.
•Reliable, repeatable, accurate process.
•Force balance principle.
•Flapper-nozzle assembly.
•Zero adjustment(turning a screw).
•Span adjustment (varying a potentiometer).
• An integral volume flow booster provides.
7. Application :
-
† Study of Linearity, Hysteresis, Accuracy and Repeatability of I/P
converter.
† Study of flapper nozzle system.
† In various industrial field, we use to measure level, flow, pressure,
temperature control system processes & lots more…
ΩOmega IP Converter
MANUFACTURER:
-
Liquid-level control system.
8. GOOD BYE…
Presented by-Presented by-Debanj anDebanj an
Uki lUki l
HI T-KHI T-K
AEI EAEI E
ROLL NO-ROLL NO- 125369125369
Along with the heartfeltAlong with the heartfelt
Special “Thank you” to the entireSpecial “Thank you” to the entire
HIT-K AEIE Department..HIT-K AEIE Department..