EMG routine

EMG
Fib and pws
What correct about these signals
1. generated in the axon
2. generated in individual muscle fibers
3. usually appear with irregular firing rhythm
4. always sign of axonal pathology
5. PSW more significant in the EDX interpretation
Fib and pws
What is correct about these signals
1. they are generated in the axon
2. generated in individual muscle fibers
3. usually appear with irregular firing rhythm
4. always sign of axonal pathology
5. PSW more significant in the EDX interpretation
EDX in demyelinating neuropathy with
conduction block
Which alternative is expected EDX finding in these conditions
1. Reduced MUP amplitudes
2. Reduced CMAP amplitudes
3. Reduced fullness of interference pattern at strong contractions
4. Abundant fibs in distal muscles
EDX in demyelinating neuropathy with
conduction block
Which alternative is expected EDX in these conditions
1. Reduced MUP amplitudes
2. Reduced CMAP amplitudes
3. Reduced fullness of interference pattern at strong contractions
4. Abundant fibs in distal muscles
56What do you call this phenomenon?
56What do you call this phenomenon?
This is CRD, complex
repetitive discharges,
not myotonia
Abrupt start and stop.
No waxing and waning
Mechanism
CRD (M gluteus) Abrupt start and stop,
complex. No jitter between components
1
2
3
4
58EMG: acute weakness
Patients with acute weakness since 2 days.
If this is GBS, which combination of findings do we get
1. normal CMAP and CV – normal MUPs and firing
2. normal CMAP , reduced CV – early reinnervation
3. Reduced CMAP ampl - first signs of denervation
4. normal CMAP, normal CV in arms and legs, reduced # F waves,
presence of A waves and abnormal interference pattern
58EMG: acute weakness
CMAP and CV changes and denervation signs have not yes developed.
Weakness is due to conduction block; thus reduced F persistence and reduced EMG pattern at effort
Patients with acute weakness since 2 days.
If this is GBS, which combination of findings do we get
1. normal CMAP and CV – normal MUPs and firing
2. normal CMAP , reduced CV – early reinnervation
3. Reduced CMAP ampl - first signs of denervation
4. normal CMAP, normal CV in arms and legs, reduced # F waves,
presence of A waves and abnormal interference pattern
Acute weakness
History:
Formerly healthy man with acute weakness from 7 days ago,
progressive symptoms.
the patient reports double vision and an unsteady gait.
Clinical:
external ophthalmoplegia, ataxia and areflexia weak facial muscles, ptosis and reduced
mobility of the tongue general mild muscle weakness. Sensory diffusely affectedF
EDX findings con´t and QUESTION
Acute weakness, EDX and Questions
Question Likely diagnosis?
GBS
Lyme disease
brainstem involvement
Miller Fischer
MG
Neurography, MCS
 general slightly decreased MCV
 F latencies extended
 DLAT extended
 distal amplitude reduced, ssk In the facial muscles
 Neurography SCS
 abnormal response with low amplitudes, more than
reduced CVEMG
 reduced interference pattern, 0 fib
 autonomous tests slightly abnormal
 abnormal Blink reflex
 prolonged latency to R1 and R2
Acute weakness, EDX and Questions
Neurography, MCS
 general slightly decreased MCV
 F latencies extended
 DLAT extended
 distal amplitude reduced, ssk In the facial muscles
 Neurography SCS
 abnormal response with low amplitudes, more than
reduced CVEMG
 reduced interference pattern, 0 fib
 autonomous tests slightly abnormal
 abnormal Blink reflex
 prolonged latency to R1 and R2
Question Likely diagnosis?
GBS
Lyme disease
brainstem involvement
Miller Fischer
MG
Discrepancies
1. Good CMAP in weak muscle, no twitch at nerve stimulation.
Normal F response.
Explanation?
conduction block
recent axonotmesis
tendon rupture
pnp
MG
myopathy
2.Good finger SNAP but no sensation at stimulation
Why?
pnp
conduction block
myelopathy
the wrong digital nerve is stimulated
GBS
3. Clear sensory experience with digital nerve stimulation but
no SNAP from the wrist
Explanation?
proximal conduction block
wrong recording position
cold hand
bipolar stim pulse has been used
the stimulus too short
4. Normal MUP and low MCV
What?
axonal pnp
conduction block
demyelination
LEM
posttraumatic reinnervation
Discrepancies
2.Good finger SNAP but no sensation at stimulation
Why?
pnp
conduction block
myelopathy
the wrong digital nerve is stimulated
GBS
3. Clear sensory experience with digital nerve stimulation but
no SNAP from the wrist
Explanation?
proximal conduction block
wrong recording position
cold hand
bipolar stim pulse has been used
the stimulus too short
4. Normal MUP and low MCV
What?
axonal pnp
conduction block
demyelination
LEM
posttraumatic reinnervation
1. Good CMAP in weak muscle, no twitch at nerve stimulation.
Normal F response.
Explanation?
conduction block
recent axonotmesis
tendon rupture
pnp
MG
myopathy
54EMG: Myasthenia?
Patient with ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal.
SFEMG in orb oculi shows jitter and some blocking. Jitter abnormal in Ext dig.
1. Ocular MG
2. Generalized MG
3. Myopathy
4. Miller Fisher syndrome
54EMG: Myasthenia?
Patient with ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal.
SFEMG in orb oculi shows jitter and some blocking. Jitter abnormal in Ext dig.
1. Ocular MG
2. Generalized MG
3. Myopathy
4. Miller Fisher syndrome
MG classification is conventionally on clinical grounds.
Jitter is abnormal in ED in 60% of cases with Ocular MG
57EMG: Myasthenia?
Patient with bilat ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal.
SFEMG in orb oculi and frontalis normal.
1. Ocular MG
2. Generalized MG
3. Myopathy
4. Bell palsy
57EMG: Myasthenia?
Patient with bilat ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal.
SFEMG in orb oculi and frontalis normal.
1. Ocular MG
2. Generalized MG
3. Myopathy
4. Bell palsy
Normal SFEMG findings are strong indications that symptoms are NOT MG. In this case, it may be
a myopathy, often with very little of jitter abnormalities
59Methods of choice
Which is the EDX method of choice for the following diagnostic questions
MG RNS
SFEMG
CTS EMG of APB and ADM
antidromic sensory neurography
GBS EMG
neurography
thermotest
Root EMG
neurography
evoked potentials
ALS EMG
neurography
Motor unit counting
59Methods of choice
Which is the EDX method of choice for the following diagnostic questions
MG RNS
SFEMG
CTS EMG of APB and ADM
antidromic sensory neurography
GBS EMG
neurography
thermotest
Root EMG
neurography
evoked potentials
ALS EMG
neurography
Motor unit counting
In routine EMG we usually ask the patient to perform a moderate to strong
contraction, and the EMG pattern is analyzed. What should the test be called?
Give a few words of argument why each of these descriptions are less than
optimal
Interference pattern usually means 50,60Hz
Summation pattern not much summation, equally much subtraction
Pattern at strong contraction neutral but complicated term
Recruitment pattern leads thoughts to the way MU are orderly recruited
In routine EMG we usually ask the patient to perform a moderate to strong
contraction, and the EMG pattern is analyzed. What should the test be called?
Give a few words of argument why each of these descriptions are less than
optimal
Interference pattern usually means 50,60Hz
Summation pattern not much summation, equally much subtraction
Pattern at strong contraction neutral but complicated term
Recruitment pattern leads thoughts to the way MU are orderly recruited
Can a MUP have a longer total
duration than the interval
between discharges of this MUP
Can a MUP have a longer total duration than
the interval between discharges of this MUP
Yes. e.g. in Duchenne MD or in
early reinnervation the duration
may be > 50 msec, corresponding
to firing rate of 20Hz. With 21Hz
firing rate, the MUP “starts
before it has ended”
Is it possible to decide whether a recorded
EMG signal originates in the nerve or in the
muscle?
From muscle = single fibre action potentials
From nerve = MUPs
Is it possible to decide whether a recorded
EMG signal originates in the nerve or in the
muscle?
From muscle = single fiber action potentials
From nerve = MUPs
Is there any difference in MUP parameters if
the recording is obtained 1 cm or 2 cm from
the end-plate?
More dispersion away from the end-plate
(duration, complexity) [6]
2 cm 5 cm
MUP from the same MU
(simulation)
Is there any difference in MUP parameters if the
recording is obtained 1 cm or 2 cm from the end-plate?
Fiber velocity 4 mm/msec. Normally the time from
start to main spike is 5 msec. Thus, in this example,
4.5 (5-0.5), 2.5 (5-2.5) and 1 (5-4) msec will be
truncated, changing shape of early phase.
2 mm
20 mm
MUP from the same MU
(simulation)
10 mm
Is there any difference in MUP parameters if
the recording is obtained 2 cm or 5 cm from
the end-plate?
More dispersion away from the end-plate
(duration, complexity) [6]
2 cm 5 cm
MUP from the same MU
(simulation)
Is there any difference in MUP parameters if
the recording is obtained 2 cm or 5 cm from
the end-plate?
More dispersion away from the end-plate
(duration, complexity) [6]
2 cm 5 cm
MUP from the same MU
(simulation)
We sometimes record double discharges (extra discharges, ED) in
voluntary EMG. Do we require that the two discharges are identical in
shape, to separate them from occasional occurrence of discharges from
2 different MUPs
Due to rel refractory period the second
discharge is lower in amplitude (interval
dependent). The succeeding ordinary
discharge may be missing [8]
We sometimes record double discharges (extra discharges, ED) in
voluntary EMG. Do we require that the two discharges are identical in
shape, to separate them from occasional occurrence of discharges from
2 different MUPs
Due to rel refractory period the second
discharge is lower in amplitude (interval
dependent). The succeeding ordinary
discharge may be missing
See more
explanation next
slide
Initial ED due to lack of Renshaw inhibition
inhibit
Renshaw
inhibit
Renshaw
Stålberg, unpublished
initiation of act ongoing act
100 ms
In voluntary EMG Extra discharges (ED) are often seen (normal) at initiation of activity after a
short pause. Where are they generated, muscle, axon, motor neurone?
They are generated in the motor neuron, probably representing impulses that initially escape the
inhibiting effect of Renshaw inhibition, catch property (1).
Stålberg 1966
Stålberg, unpublished
See more
explanation next
slide
Initial ED due to lack of Renshaw inhibition
inhibit
Renshaw
inhibit
Renshaw
Stålberg, unpublished
initiation of act ongoing act
100 ms
In voluntary EMG Extra discharges (ED) are often seen (normal) at initiation of activity after a
short pause. Where are they generated, muscle, axon, motor neurone?
They are generated in the motor neuron, probably representing impulses that initially escape the
inhibiting effect of Renshaw inhibition, catch property .
Stålberg 1966
Stålberg, unpublished
Initial ED due to lack of Renshaw inhibition
inbit
Renshaw
inbit
Renshaw
Stålberg, unpublished
At initiation of activity, the motor neurone produces a high
firing rate (100HZ) (inferred by Stålberg). Via retrograde Renshaw
inhibition, the firing rate of the neurone is reduced and kept there.
This has been called “catch” property (Burke, Rudomin et al. 1970)
During ongoing activation, there is a balance between neurone
firings and the Renshaw inhibition. Theoretically ED may occur if
Renshaw inhibition is lacking (neuropathy?, cyanid???)
initiation steady activation
Critical illness: are fibrillations in these
patients usually a sign of neuropathy
(CIP)
No, seen both in CIM and CIP.
A sign of membrane hyperexcitability,
not necessarily indicating denervation
Critical illness: are fibrillations in these
patients usually a sign of neuropathy
(CIP)
No, seen both in CIM and CIP.
A sign of membrane hyperexcitability,
not necessarily indicating denervation
Critical illness: is the myosin content
lower in CIM than in CIP
Yes
Critical illness: is the myosin content
lower in CIM than in CIP
Yes
Critical illness: is sural amplitude
different in CIM and CIP
In principle normal in myopathy, but
abnormal in CIP
Critical illness: is sural amplitude
different in CIM and CIP
In principle normal in myopathy, but
abnormal in CIP
Monopolar recording. Is there any difference in the pattern at
voluntary contraction if the distance between the two recording
monopolar electrodes (“active” and “reference”) is 1 cm or 10
cm?
With 1 cm or smaller the electrodes record
to some extent from the same MUPs, and
common activity (green) is cancelled.
With separate electrodes, you will get the
difference of independent activity from the two.
Monopolar recording. Is there any difference in the pattern at
voluntary contraction if the distance between the two recording
monopolar electrodes (“active” and “reference”) is 1 cm or 10
cm?
With 1 cm or smaller the electrodes record
to some extent from the same MUPs, and
common activity (green) is cancelled.
With separate electrodes, you will get the
difference of independent activity from the two,
in effect a summation of acitivties.
The derivation is between the needle electrode (E1) and the reference (E2).
Activity from the reference is crucial:
In monopolar EMG the reference may be a surface electrode. If this is adjacent to the muscle under study,
the surface EMG signal will be seen on the baseline of the recording
In CNE the reference is the needle cannula. Activity from surrounding fibers contribute with similar signal
to the tip electrode and the ref and is therefore cancelled
Monopolar EMG. Why is the baseline
sometimes more “unstable” than with CNE
The derivation is between the needle electrode (E1) and the reference (E2).
Activity from the reference is crucial:
In monopolar EMG the reference may be a surface electrode.
If this is adjacent to the muscle under study, the surface EMG signal
will be seen on the baseline of the recording
In CNE the reference is the needle cannula. Activity from surrounding fibers
contribute with similar signal to the tip electrode and the ref and is therefore cancelled
Monopolar EMG. Why is the baseline
sometimes more “unstable” than with CNE
Can you detect the “size principle” with
conventional needle electrodes?
No, the uptake are of mono/con
electrodes is about 2 mm and the
MUP often 5-10 mm in diameter,
so you do not know if you are
recording from a small or large MU. [2]
Can you detect the “size principle” with
conventional needle electrodes?
No, the uptake are of mono/con
electrodes is about 2 mm and the
MUP often 5-10 mm in diameter,
so you do not know if you are
recording from a small or large MU. [2]
Concentric electrode has an oval recording surface: are
the MUP parameters different for transversal or
longitudinal insertion of the electrode (in relation to the
fiber direction).
Yes, but this is never taken into account. Ref values are
obtained with any electrode rotation
Concentric electrode has an oval recording surface: are
the MUP parameters different for transversal or
longitudinal insertion of the electrode (in relation to the
fiber direction).
Yes, but this is never taken into account. Ref values are
obtained with any electrode rotation
Which is the concentric needle electrode recording
uptake field (180 or 360 degree) for the duration
parameter in a MUP
Which is the concentric needle electrode recording
uptake field (180 or 360 degree) for the spiky part of
the MUP
For Duration: about 2 mm, spherical. For Spiky part,
about 0,5 mm, hemispherical[4, 5]
Which is the concentric needle electrode recording
uptake field (180 or 360 degree) for the duration
parameter in a MUP
Which is the concentric needle electrode recording
uptake field (180 or 360 degree) for the spiky part of
the MUP
For Duration: about 2 mm, spherical. For Spiky part,
about 0,5 mm, hemispherical[4, 5]
Is it possible to make sure that you are stimulating
muscle fibers directly and not intramuscular nerves in
so called direct muscle stimulation (critical illness
tests)
Yes, by measuring the jitter. < 5usec if direct
stimulation [7]
Is it possible to make sure that you are stimulating
muscle fibers directly and not intramuscular nerves in
so called direct muscle stimulation (critical illness
tests)
Yes, by measuring the jitter. < 5usec if direct
stimulation [7]
In monopolar EMG recording you often see a small
positive going signal on the end slope of the signal.
What is this, and why do you not see that in concentric
needle EMG
This is a far field signal generated at the tendon. Since it is a far field
potential it is recorded equally well with the tip as with the cannula in
the concentric electrode and therefore cancelled. [4]
With increasing force, the needle EMG amplitude
(envelope amplitude) increases. Why?
It is not the “size principle”, but a statistical
phenomenon, with increasing chance of recording
from the closest muscle fibers, with increasing force
level.
With increasing force, the needle EMG amplitude
(envelope amplitude) increases. Why?
It is not the “size principle”, but a statistical
phenomenon with increasing chance of recording from
the closest muscle fibers, with increasing force level.
In concentric needle electrode recordings, one can
sometimes obtain low amplitude MUP that looks “upside
down”. Explanation?
1. Signals are mainly recorded by the cannula
2. Obtained close to the tendon
In concentric needle electrode recordings, one can
sometimes obtain low amplitude MUP that looks “upside
down”. Explanation?
1. Signals are mainly recorded by the cannula
2. Obtained close to the tendon
Reinnervation. In the early stage of collateral
reinnervation (20 days) after a partial nerve lesion, you
start to see MUPs with some jittering spikes. In general
is the MUP “small” or “normal – slightly increased”?
Collateral reinnervation takes place from a normal MU, so the
reinnervated MU should be larger than a normal MU. We get small
MUs, “nascent” MUPs only after complete nerve lesion followed by
nerve regrowth.
Reinnervation. In the early stage of collateral
reinnervation (20 days) after a partial nerve lesion, you
start to see MUPs with some jittering spikes. In general
is the MUP “small” or “normal – slightly increased”?
Collateral reinnervation takes place from a normal MU, so the
reinnervated MU should be larger than a normal MU.
We get small MUs, “nascent” MUPs only after complete nerve lesion
followed by nerve regrowth.
One month of increasing muscular weakness
Background
21 yo man with slowly increasing symptoms since 1 month.
Mainly muscle pain, weakness, especially in the arms. No diurnal variation.
No trauma or other known trigger.
Since previously asthma. On one occasion venous thrombosis in the left arm.
Clinic:
cranial nerves OK with the exception of neck flexor weakness.
Arms and legs show muscular weakness proximally. Normal reflexes, Babinski plantar.
Normal sensibility in arms and legs. Normal finger-nose test. Can't walk normally
No skin abnormalities
Lab: P-myoglobin=693 (24-77)
P-Creatine Kinase=6050 (50-400)
Median nerve:
Q6
Neurografi
Ulnar nerve
Q6
m. Vastus lateralis dxt
Q6
m. Deltoideus dxt
Q6
m. Deltoideus dxt
m. Biceps brachii dxt
m. Biceps brachii dxt
Q6
Ultrasonography:
In the right Deltoid muscle there is
partiel hyperecchogenic changes
with an impression of increased
interstitel vascularisation
(as compared to m. EDC, m. Vastus
lateralis and m. Tibialis anterior).
Q6
Summary:
Clinical proximal weakness
Neurography normal.
EMG myopathic MUPs, IP and fibs
Ultrasound: hyperechogenicity and increased vascularization in the deltoid.
Muscle biopsy: fiber diameter variation, no grouping but other findings
Question Likely diagnosis
myositis
MND in early stages
virus
Simvastatin side effect
metabolic disorder
Summary:
Clinical proximal weakness
Neurography normal.
EMG myopathic MUPs, IP and fibs
Ultrasound: hyperechogenicity and increased vascularization in the deltoid.
Muscle biopsy: fiber diameter variation, no grouping but other findings
Question Likely diagnosis
myositis
MND in early stages
virus
Simvastatin side effect
metabolic disorder
Q5
30 year old woman
Past history: depression, ME/CFS, back problems
Currently:
A week with acute pain in the right and after a few days also the
left shoulder/upper arm. Some pain in right leg. Weakness in
painful areas.
Rheumatologist assesses pat has reactive arthritis - gives
steroids.
Then neurologist consultant. Finds the diagnosis unclear and
suggests neurophysiology
Q5
Neurological examination
Right-sided scapulae alata
Bilateral weakness: Finger extension, wrist extension (and flexion).
reduced sensibility over the right thumb and radially on the forearm
Neurography:
Motor MCV and F-responses: N. medianus and nervus ulnaris: Normal MCV and Normal F-laten
Sensory SCS: Right n. cutaneous antebrachii lateralis: Low amplitude
Normal findings forN. medianus (Volar, finger 1 and 3),
n ulnaris ( finger 5),n. radialis, n. cutaneus antebrachii medialis
Q: Most likely diagnosis:
a. Parsonage Turner syndrome
b. MND
c. radiculopathy
d. focal accessory damage
e. “flail arm”
Q5
EMG:
Right m. biceps brachii, m. deltoideus bilat, left m. flexor carpi radialis and m. flexor carpi ulnaris. - NORMAL
Right m. serratus anterior: Normal amplitude and duration of MUPs. Fibrillation potentials and positive sharp
waves ++.
Bilat m. flexor pollicis longus: 0 MUPs. Fibrillation potentials and positive sharp waves ++
Right m. extensor digitorum: Slight MUP changes Fibrillation potentials and positive sharp waves +.
Reference List
1. Burke RE, Rudomin P, Zajac FEIII. Catch property in single mammalian motor units. Science.
1970;168:122-4.
2. Ertas M, Stalberg E, Falck B. Can the size principle be detected in conventional EMG recordings?
Muscle Nerve. 1995;18:435-9.
3. Gydikov A, Kosarov D. Extraterritorial potential field of impulses from separate motor units in
human muscles. Electromyography Clinical Neurophysiology. 1972;12:283-305.
4. Nandedkar SD, Sanders DB. Recording characteristics of monopolar EMG electrodes. Muscle
Nerve. 1991;14:108-12.
5. Nandedkar SD, Sanders DB, Stålberg E. Selectivity of electromyographic recording techniques; a
simulation study. Med Biol Eng Comput. 1985;23:536-40.
6. Stålberg E, Karlsson L. Simulation of the normal concentric needle electromyogram by using a
muscle model. ClinNeurophysiol. 2001;112:464-71.
7. Stålberg E, Trontelj JV, Mihelin M. Electrical microstimulation with single-fiber
electromyography: a useful method to study the physiology of the motor unit. Journal of
Clinical Neurophysiology. 1992;9:105-19.
8. Stålberg E, Trontelj JV, Sanders DB. Single Fiber EMG. 3rd ed. Uppsala: Edshagen Publishing
House; 2010.
1 de 76

Recomendados

EMG routine por
EMG routineEMG routine
EMG routineErik Stålberg
67 visualizações21 slides
NCS routine por
NCS routineNCS routine
NCS routineBenjamin614958
61 visualizações102 slides
NCS routine por
NCS routineNCS routine
NCS routineErik Stålberg
50 visualizações52 slides
EMG special por
EMG specialEMG special
EMG specialErik Stålberg
37 visualizações60 slides
A Case of Oro-Facio-Bulbar weakness por
A Case of Oro-Facio-Bulbar weaknessA Case of Oro-Facio-Bulbar weakness
A Case of Oro-Facio-Bulbar weaknessStanley Medical College, Department of Medicine
1.2K visualizações37 slides
Neurophysiological investigations por
Neurophysiological investigationsNeurophysiological investigations
Neurophysiological investigationsFaculty of Medicine Ain Shams University
1.3K visualizações34 slides

Mais conteúdo relacionado

Similar a EMG routine

EMG&RNST por
EMG&RNSTEMG&RNST
EMG&RNSTNeurologyKota
1.8K visualizações25 slides
AIDPCIDP MMN Stålberg por
AIDPCIDP MMN StålbergAIDPCIDP MMN Stålberg
AIDPCIDP MMN StålbergErik Stålberg
592 visualizações40 slides
QUIZ RNS por
QUIZ RNSQUIZ RNS
QUIZ RNSErik Stålberg
24 visualizações16 slides
NEUROMUSCULAR JUNCTION [Autosaved].pptx por
NEUROMUSCULAR JUNCTION [Autosaved].pptxNEUROMUSCULAR JUNCTION [Autosaved].pptx
NEUROMUSCULAR JUNCTION [Autosaved].pptxshalajjain
16 visualizações75 slides
Entrapment Neuropathies in Upper Limb.pptx por
Entrapment Neuropathies in Upper Limb.pptxEntrapment Neuropathies in Upper Limb.pptx
Entrapment Neuropathies in Upper Limb.pptxNeurologyKota
591 visualizações65 slides
Electrodiagnosis in gbs por
Electrodiagnosis in gbsElectrodiagnosis in gbs
Electrodiagnosis in gbsDr. Munish Kumar
294 visualizações15 slides

Similar a EMG routine(20)

EMG&RNST por NeurologyKota
EMG&RNSTEMG&RNST
EMG&RNST
NeurologyKota1.8K visualizações
AIDPCIDP MMN Stålberg por Erik Stålberg
AIDPCIDP MMN StålbergAIDPCIDP MMN Stålberg
AIDPCIDP MMN Stålberg
Erik Stålberg592 visualizações
QUIZ RNS por Erik Stålberg
QUIZ RNSQUIZ RNS
QUIZ RNS
Erik Stålberg24 visualizações
NEUROMUSCULAR JUNCTION [Autosaved].pptx por shalajjain
NEUROMUSCULAR JUNCTION [Autosaved].pptxNEUROMUSCULAR JUNCTION [Autosaved].pptx
NEUROMUSCULAR JUNCTION [Autosaved].pptx
shalajjain16 visualizações
Entrapment Neuropathies in Upper Limb.pptx por NeurologyKota
Entrapment Neuropathies in Upper Limb.pptxEntrapment Neuropathies in Upper Limb.pptx
Entrapment Neuropathies in Upper Limb.pptx
NeurologyKota591 visualizações
Electrodiagnosis in gbs por Dr. Munish Kumar
Electrodiagnosis in gbsElectrodiagnosis in gbs
Electrodiagnosis in gbs
Dr. Munish Kumar294 visualizações
NCS DDH.pptx por Bagadi Suneel
NCS DDH.pptxNCS DDH.pptx
NCS DDH.pptx
Bagadi Suneel41 visualizações
Approach to NMJ disorders.pptx por Zelekewoldeyohannes
Approach to NMJ disorders.pptxApproach to NMJ disorders.pptx
Approach to NMJ disorders.pptx
Zelekewoldeyohannes2 visualizações
Fundamentals of nerve conduction study por NeurologyKota
Fundamentals of nerve conduction studyFundamentals of nerve conduction study
Fundamentals of nerve conduction study
NeurologyKota29.8K visualizações
jc on bells palsy.pptx por Dr. Harsh Verma
jc on bells palsy.pptxjc on bells palsy.pptx
jc on bells palsy.pptx
Dr. Harsh Verma2 visualizações
Nerves conduction study, Axonal loss vs Demyelination por Ahmad Shahir
Nerves conduction study, Axonal loss vs DemyelinationNerves conduction study, Axonal loss vs Demyelination
Nerves conduction study, Axonal loss vs Demyelination
Ahmad Shahir45.1K visualizações
Repetitive Nerve Stimulation (RNS) por Murtaza Syed
Repetitive Nerve Stimulation (RNS)Repetitive Nerve Stimulation (RNS)
Repetitive Nerve Stimulation (RNS)
Murtaza Syed25.1K visualizações
Brainstem auditory evoked potentials (baep) por NeurologyKota
Brainstem auditory evoked potentials (baep)Brainstem auditory evoked potentials (baep)
Brainstem auditory evoked potentials (baep)
NeurologyKota7.4K visualizações
NCS special por Erik Stålberg
NCS specialNCS special
NCS special
Erik Stålberg35 visualizações
Lumbar Spine Emg por Satyajit Mohanty
Lumbar Spine EmgLumbar Spine Emg
Lumbar Spine Emg
Satyajit Mohanty4K visualizações
Carpal tunnel syndrome por Dr.A.Mohan krishna
Carpal tunnel syndromeCarpal tunnel syndrome
Carpal tunnel syndrome
Dr.A.Mohan krishna27.5K visualizações
Lambert Eaton Myasthenic Syndrome (LEMS) por Chee Oh
Lambert Eaton Myasthenic Syndrome (LEMS)Lambert Eaton Myasthenic Syndrome (LEMS)
Lambert Eaton Myasthenic Syndrome (LEMS)
Chee Oh12K visualizações
Approach to the_patient_with_myopathy por Mohit Aggarwal
Approach to the_patient_with_myopathyApproach to the_patient_with_myopathy
Approach to the_patient_with_myopathy
Mohit Aggarwal1.9K visualizações

Último

Biomedicine & Pharmacotherapy por
Biomedicine & PharmacotherapyBiomedicine & Pharmacotherapy
Biomedicine & PharmacotherapyTrustlife
220 visualizações12 slides
Looking For Exceptional Dental Care In Simi Valley We’ve Got The Answer por
Looking For Exceptional Dental Care In Simi Valley We’ve Got The AnswerLooking For Exceptional Dental Care In Simi Valley We’ve Got The Answer
Looking For Exceptional Dental Care In Simi Valley We’ve Got The AnswerDental Group of Simi Valley
26 visualizações26 slides
Examining Pleural Fluid.pptx por
Examining Pleural Fluid.pptxExamining Pleural Fluid.pptx
Examining Pleural Fluid.pptxFareeha Riaz
21 visualizações18 slides
ICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptx por
ICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptxICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptx
ICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptxABG
65 visualizações45 slides
The A-Team Against Relapsed/Refractory Myeloma: Community Strategies for Enha... por
The A-Team Against Relapsed/Refractory Myeloma: Community Strategies for Enha...The A-Team Against Relapsed/Refractory Myeloma: Community Strategies for Enha...
The A-Team Against Relapsed/Refractory Myeloma: Community Strategies for Enha...PVI, PeerView Institute for Medical Education
14 visualizações44 slides
Breast Ductography.pptx por
Breast Ductography.pptxBreast Ductography.pptx
Breast Ductography.pptxPeerzadaJunaidUlIsla
44 visualizações18 slides

Último(20)

Biomedicine & Pharmacotherapy por Trustlife
Biomedicine & PharmacotherapyBiomedicine & Pharmacotherapy
Biomedicine & Pharmacotherapy
Trustlife220 visualizações
Looking For Exceptional Dental Care In Simi Valley We’ve Got The Answer por Dental Group of Simi Valley
Looking For Exceptional Dental Care In Simi Valley We’ve Got The AnswerLooking For Exceptional Dental Care In Simi Valley We’ve Got The Answer
Looking For Exceptional Dental Care In Simi Valley We’ve Got The Answer
Dental Group of Simi Valley26 visualizações
Examining Pleural Fluid.pptx por Fareeha Riaz
Examining Pleural Fluid.pptxExamining Pleural Fluid.pptx
Examining Pleural Fluid.pptx
Fareeha Riaz 21 visualizações
ICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptx por ABG
ICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptxICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptx
ICH AND WHO GUIDELINES FOR VALIDATION OF EQUIPMENTS.pptx
ABG65 visualizações
Epilepsy and Anti epileptic drugs .pdf por A. Gowtham Sashtha
Epilepsy and Anti epileptic drugs .pdfEpilepsy and Anti epileptic drugs .pdf
Epilepsy and Anti epileptic drugs .pdf
A. Gowtham Sashtha20 visualizações
Top Ayurvedic PCD Companies in India Riding the Wave of Wellness Trends por muskansbl01
Top Ayurvedic PCD Companies in India Riding the Wave of Wellness TrendsTop Ayurvedic PCD Companies in India Riding the Wave of Wellness Trends
Top Ayurvedic PCD Companies in India Riding the Wave of Wellness Trends
muskansbl0159 visualizações
Size reduction.pptx por shubhammhaske31
Size reduction.pptxSize reduction.pptx
Size reduction.pptx
shubhammhaske3116 visualizações
Thrives Priority Areas: Behavioral Health por City of Chesapeake
Thrives Priority Areas: Behavioral HealthThrives Priority Areas: Behavioral Health
Thrives Priority Areas: Behavioral Health
City of Chesapeake93 visualizações
Complications & Solutions in Laparoscopic Hernia Surgery.pptx por Varunraju9
Complications & Solutions in Laparoscopic Hernia Surgery.pptxComplications & Solutions in Laparoscopic Hernia Surgery.pptx
Complications & Solutions in Laparoscopic Hernia Surgery.pptx
Varunraju9135 visualizações
INTRODUCTION TO PHARMACEUTICAL VALIDATION SCOPE and MERITS OF VALIDATION.pptx por ABG
INTRODUCTION TO PHARMACEUTICAL VALIDATION SCOPE and MERITS OF VALIDATION.pptxINTRODUCTION TO PHARMACEUTICAL VALIDATION SCOPE and MERITS OF VALIDATION.pptx
INTRODUCTION TO PHARMACEUTICAL VALIDATION SCOPE and MERITS OF VALIDATION.pptx
ABG120 visualizações
VarSeq 2.5.0: VSClinical AMP Workflow from the User Perspective por Golden Helix
VarSeq 2.5.0: VSClinical AMP Workflow from the User PerspectiveVarSeq 2.5.0: VSClinical AMP Workflow from the User Perspective
VarSeq 2.5.0: VSClinical AMP Workflow from the User Perspective
Golden Helix108 visualizações
PATIENTCOUNSELLING in.pptx por skShashi1
PATIENTCOUNSELLING  in.pptxPATIENTCOUNSELLING  in.pptx
PATIENTCOUNSELLING in.pptx
skShashi145 visualizações
Asthalin Inhaler (Generic Albuterol Sulfate Inhaler) por The Swiss Pharmacy
Asthalin Inhaler (Generic Albuterol Sulfate Inhaler) Asthalin Inhaler (Generic Albuterol Sulfate Inhaler)
Asthalin Inhaler (Generic Albuterol Sulfate Inhaler)
The Swiss Pharmacy16 visualizações
Testicular tumors.pptx por Utkarsh Singhal
Testicular tumors.pptxTesticular tumors.pptx
Testicular tumors.pptx
Utkarsh Singhal32 visualizações
BODY COMPOSITION.pptx por AneriPatwari
BODY COMPOSITION.pptxBODY COMPOSITION.pptx
BODY COMPOSITION.pptx
AneriPatwari50 visualizações
HYPERTENSION.pptx por Yogesh684750
HYPERTENSION.pptxHYPERTENSION.pptx
HYPERTENSION.pptx
Yogesh68475029 visualizações

EMG routine

  • 1. EMG
  • 2. Fib and pws What correct about these signals 1. generated in the axon 2. generated in individual muscle fibers 3. usually appear with irregular firing rhythm 4. always sign of axonal pathology 5. PSW more significant in the EDX interpretation
  • 3. Fib and pws What is correct about these signals 1. they are generated in the axon 2. generated in individual muscle fibers 3. usually appear with irregular firing rhythm 4. always sign of axonal pathology 5. PSW more significant in the EDX interpretation
  • 4. EDX in demyelinating neuropathy with conduction block Which alternative is expected EDX finding in these conditions 1. Reduced MUP amplitudes 2. Reduced CMAP amplitudes 3. Reduced fullness of interference pattern at strong contractions 4. Abundant fibs in distal muscles
  • 5. EDX in demyelinating neuropathy with conduction block Which alternative is expected EDX in these conditions 1. Reduced MUP amplitudes 2. Reduced CMAP amplitudes 3. Reduced fullness of interference pattern at strong contractions 4. Abundant fibs in distal muscles
  • 6. 56What do you call this phenomenon?
  • 7. 56What do you call this phenomenon? This is CRD, complex repetitive discharges, not myotonia Abrupt start and stop. No waxing and waning
  • 8. Mechanism CRD (M gluteus) Abrupt start and stop, complex. No jitter between components 1 2 3 4
  • 9. 58EMG: acute weakness Patients with acute weakness since 2 days. If this is GBS, which combination of findings do we get 1. normal CMAP and CV – normal MUPs and firing 2. normal CMAP , reduced CV – early reinnervation 3. Reduced CMAP ampl - first signs of denervation 4. normal CMAP, normal CV in arms and legs, reduced # F waves, presence of A waves and abnormal interference pattern
  • 10. 58EMG: acute weakness CMAP and CV changes and denervation signs have not yes developed. Weakness is due to conduction block; thus reduced F persistence and reduced EMG pattern at effort Patients with acute weakness since 2 days. If this is GBS, which combination of findings do we get 1. normal CMAP and CV – normal MUPs and firing 2. normal CMAP , reduced CV – early reinnervation 3. Reduced CMAP ampl - first signs of denervation 4. normal CMAP, normal CV in arms and legs, reduced # F waves, presence of A waves and abnormal interference pattern
  • 11. Acute weakness History: Formerly healthy man with acute weakness from 7 days ago, progressive symptoms. the patient reports double vision and an unsteady gait. Clinical: external ophthalmoplegia, ataxia and areflexia weak facial muscles, ptosis and reduced mobility of the tongue general mild muscle weakness. Sensory diffusely affectedF EDX findings con´t and QUESTION
  • 12. Acute weakness, EDX and Questions Question Likely diagnosis? GBS Lyme disease brainstem involvement Miller Fischer MG Neurography, MCS  general slightly decreased MCV  F latencies extended  DLAT extended  distal amplitude reduced, ssk In the facial muscles  Neurography SCS  abnormal response with low amplitudes, more than reduced CVEMG  reduced interference pattern, 0 fib  autonomous tests slightly abnormal  abnormal Blink reflex  prolonged latency to R1 and R2
  • 13. Acute weakness, EDX and Questions Neurography, MCS  general slightly decreased MCV  F latencies extended  DLAT extended  distal amplitude reduced, ssk In the facial muscles  Neurography SCS  abnormal response with low amplitudes, more than reduced CVEMG  reduced interference pattern, 0 fib  autonomous tests slightly abnormal  abnormal Blink reflex  prolonged latency to R1 and R2 Question Likely diagnosis? GBS Lyme disease brainstem involvement Miller Fischer MG
  • 14. Discrepancies 1. Good CMAP in weak muscle, no twitch at nerve stimulation. Normal F response. Explanation? conduction block recent axonotmesis tendon rupture pnp MG myopathy 2.Good finger SNAP but no sensation at stimulation Why? pnp conduction block myelopathy the wrong digital nerve is stimulated GBS 3. Clear sensory experience with digital nerve stimulation but no SNAP from the wrist Explanation? proximal conduction block wrong recording position cold hand bipolar stim pulse has been used the stimulus too short 4. Normal MUP and low MCV What? axonal pnp conduction block demyelination LEM posttraumatic reinnervation
  • 15. Discrepancies 2.Good finger SNAP but no sensation at stimulation Why? pnp conduction block myelopathy the wrong digital nerve is stimulated GBS 3. Clear sensory experience with digital nerve stimulation but no SNAP from the wrist Explanation? proximal conduction block wrong recording position cold hand bipolar stim pulse has been used the stimulus too short 4. Normal MUP and low MCV What? axonal pnp conduction block demyelination LEM posttraumatic reinnervation 1. Good CMAP in weak muscle, no twitch at nerve stimulation. Normal F response. Explanation? conduction block recent axonotmesis tendon rupture pnp MG myopathy
  • 16. 54EMG: Myasthenia? Patient with ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal. SFEMG in orb oculi shows jitter and some blocking. Jitter abnormal in Ext dig. 1. Ocular MG 2. Generalized MG 3. Myopathy 4. Miller Fisher syndrome
  • 17. 54EMG: Myasthenia? Patient with ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal. SFEMG in orb oculi shows jitter and some blocking. Jitter abnormal in Ext dig. 1. Ocular MG 2. Generalized MG 3. Myopathy 4. Miller Fisher syndrome MG classification is conventionally on clinical grounds. Jitter is abnormal in ED in 60% of cases with Ocular MG
  • 18. 57EMG: Myasthenia? Patient with bilat ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal. SFEMG in orb oculi and frontalis normal. 1. Ocular MG 2. Generalized MG 3. Myopathy 4. Bell palsy
  • 19. 57EMG: Myasthenia? Patient with bilat ptosis but no arm or leg weakness. RNS in nasalis and deltoid normal. SFEMG in orb oculi and frontalis normal. 1. Ocular MG 2. Generalized MG 3. Myopathy 4. Bell palsy Normal SFEMG findings are strong indications that symptoms are NOT MG. In this case, it may be a myopathy, often with very little of jitter abnormalities
  • 20. 59Methods of choice Which is the EDX method of choice for the following diagnostic questions MG RNS SFEMG CTS EMG of APB and ADM antidromic sensory neurography GBS EMG neurography thermotest Root EMG neurography evoked potentials ALS EMG neurography Motor unit counting
  • 21. 59Methods of choice Which is the EDX method of choice for the following diagnostic questions MG RNS SFEMG CTS EMG of APB and ADM antidromic sensory neurography GBS EMG neurography thermotest Root EMG neurography evoked potentials ALS EMG neurography Motor unit counting
  • 22. In routine EMG we usually ask the patient to perform a moderate to strong contraction, and the EMG pattern is analyzed. What should the test be called? Give a few words of argument why each of these descriptions are less than optimal Interference pattern usually means 50,60Hz Summation pattern not much summation, equally much subtraction Pattern at strong contraction neutral but complicated term Recruitment pattern leads thoughts to the way MU are orderly recruited
  • 23. In routine EMG we usually ask the patient to perform a moderate to strong contraction, and the EMG pattern is analyzed. What should the test be called? Give a few words of argument why each of these descriptions are less than optimal Interference pattern usually means 50,60Hz Summation pattern not much summation, equally much subtraction Pattern at strong contraction neutral but complicated term Recruitment pattern leads thoughts to the way MU are orderly recruited
  • 24. Can a MUP have a longer total duration than the interval between discharges of this MUP
  • 25. Can a MUP have a longer total duration than the interval between discharges of this MUP Yes. e.g. in Duchenne MD or in early reinnervation the duration may be > 50 msec, corresponding to firing rate of 20Hz. With 21Hz firing rate, the MUP “starts before it has ended”
  • 26. Is it possible to decide whether a recorded EMG signal originates in the nerve or in the muscle? From muscle = single fibre action potentials From nerve = MUPs
  • 27. Is it possible to decide whether a recorded EMG signal originates in the nerve or in the muscle? From muscle = single fiber action potentials From nerve = MUPs
  • 28. Is there any difference in MUP parameters if the recording is obtained 1 cm or 2 cm from the end-plate? More dispersion away from the end-plate (duration, complexity) [6] 2 cm 5 cm MUP from the same MU (simulation)
  • 29. Is there any difference in MUP parameters if the recording is obtained 1 cm or 2 cm from the end-plate? Fiber velocity 4 mm/msec. Normally the time from start to main spike is 5 msec. Thus, in this example, 4.5 (5-0.5), 2.5 (5-2.5) and 1 (5-4) msec will be truncated, changing shape of early phase. 2 mm 20 mm MUP from the same MU (simulation) 10 mm
  • 30. Is there any difference in MUP parameters if the recording is obtained 2 cm or 5 cm from the end-plate? More dispersion away from the end-plate (duration, complexity) [6] 2 cm 5 cm MUP from the same MU (simulation)
  • 31. Is there any difference in MUP parameters if the recording is obtained 2 cm or 5 cm from the end-plate? More dispersion away from the end-plate (duration, complexity) [6] 2 cm 5 cm MUP from the same MU (simulation)
  • 32. We sometimes record double discharges (extra discharges, ED) in voluntary EMG. Do we require that the two discharges are identical in shape, to separate them from occasional occurrence of discharges from 2 different MUPs Due to rel refractory period the second discharge is lower in amplitude (interval dependent). The succeeding ordinary discharge may be missing [8]
  • 33. We sometimes record double discharges (extra discharges, ED) in voluntary EMG. Do we require that the two discharges are identical in shape, to separate them from occasional occurrence of discharges from 2 different MUPs Due to rel refractory period the second discharge is lower in amplitude (interval dependent). The succeeding ordinary discharge may be missing
  • 34. See more explanation next slide Initial ED due to lack of Renshaw inhibition inhibit Renshaw inhibit Renshaw Stålberg, unpublished initiation of act ongoing act 100 ms In voluntary EMG Extra discharges (ED) are often seen (normal) at initiation of activity after a short pause. Where are they generated, muscle, axon, motor neurone? They are generated in the motor neuron, probably representing impulses that initially escape the inhibiting effect of Renshaw inhibition, catch property (1). Stålberg 1966 Stålberg, unpublished
  • 35. See more explanation next slide Initial ED due to lack of Renshaw inhibition inhibit Renshaw inhibit Renshaw Stålberg, unpublished initiation of act ongoing act 100 ms In voluntary EMG Extra discharges (ED) are often seen (normal) at initiation of activity after a short pause. Where are they generated, muscle, axon, motor neurone? They are generated in the motor neuron, probably representing impulses that initially escape the inhibiting effect of Renshaw inhibition, catch property . Stålberg 1966 Stålberg, unpublished
  • 36. Initial ED due to lack of Renshaw inhibition inbit Renshaw inbit Renshaw Stålberg, unpublished At initiation of activity, the motor neurone produces a high firing rate (100HZ) (inferred by Stålberg). Via retrograde Renshaw inhibition, the firing rate of the neurone is reduced and kept there. This has been called “catch” property (Burke, Rudomin et al. 1970) During ongoing activation, there is a balance between neurone firings and the Renshaw inhibition. Theoretically ED may occur if Renshaw inhibition is lacking (neuropathy?, cyanid???) initiation steady activation
  • 37. Critical illness: are fibrillations in these patients usually a sign of neuropathy (CIP) No, seen both in CIM and CIP. A sign of membrane hyperexcitability, not necessarily indicating denervation
  • 38. Critical illness: are fibrillations in these patients usually a sign of neuropathy (CIP) No, seen both in CIM and CIP. A sign of membrane hyperexcitability, not necessarily indicating denervation
  • 39. Critical illness: is the myosin content lower in CIM than in CIP Yes
  • 40. Critical illness: is the myosin content lower in CIM than in CIP Yes
  • 41. Critical illness: is sural amplitude different in CIM and CIP In principle normal in myopathy, but abnormal in CIP
  • 42. Critical illness: is sural amplitude different in CIM and CIP In principle normal in myopathy, but abnormal in CIP
  • 43. Monopolar recording. Is there any difference in the pattern at voluntary contraction if the distance between the two recording monopolar electrodes (“active” and “reference”) is 1 cm or 10 cm? With 1 cm or smaller the electrodes record to some extent from the same MUPs, and common activity (green) is cancelled. With separate electrodes, you will get the difference of independent activity from the two.
  • 44. Monopolar recording. Is there any difference in the pattern at voluntary contraction if the distance between the two recording monopolar electrodes (“active” and “reference”) is 1 cm or 10 cm? With 1 cm or smaller the electrodes record to some extent from the same MUPs, and common activity (green) is cancelled. With separate electrodes, you will get the difference of independent activity from the two, in effect a summation of acitivties.
  • 45. The derivation is between the needle electrode (E1) and the reference (E2). Activity from the reference is crucial: In monopolar EMG the reference may be a surface electrode. If this is adjacent to the muscle under study, the surface EMG signal will be seen on the baseline of the recording In CNE the reference is the needle cannula. Activity from surrounding fibers contribute with similar signal to the tip electrode and the ref and is therefore cancelled Monopolar EMG. Why is the baseline sometimes more “unstable” than with CNE
  • 46. The derivation is between the needle electrode (E1) and the reference (E2). Activity from the reference is crucial: In monopolar EMG the reference may be a surface electrode. If this is adjacent to the muscle under study, the surface EMG signal will be seen on the baseline of the recording In CNE the reference is the needle cannula. Activity from surrounding fibers contribute with similar signal to the tip electrode and the ref and is therefore cancelled Monopolar EMG. Why is the baseline sometimes more “unstable” than with CNE
  • 47. Can you detect the “size principle” with conventional needle electrodes? No, the uptake are of mono/con electrodes is about 2 mm and the MUP often 5-10 mm in diameter, so you do not know if you are recording from a small or large MU. [2]
  • 48. Can you detect the “size principle” with conventional needle electrodes? No, the uptake are of mono/con electrodes is about 2 mm and the MUP often 5-10 mm in diameter, so you do not know if you are recording from a small or large MU. [2]
  • 49. Concentric electrode has an oval recording surface: are the MUP parameters different for transversal or longitudinal insertion of the electrode (in relation to the fiber direction). Yes, but this is never taken into account. Ref values are obtained with any electrode rotation
  • 50. Concentric electrode has an oval recording surface: are the MUP parameters different for transversal or longitudinal insertion of the electrode (in relation to the fiber direction). Yes, but this is never taken into account. Ref values are obtained with any electrode rotation
  • 51. Which is the concentric needle electrode recording uptake field (180 or 360 degree) for the duration parameter in a MUP Which is the concentric needle electrode recording uptake field (180 or 360 degree) for the spiky part of the MUP For Duration: about 2 mm, spherical. For Spiky part, about 0,5 mm, hemispherical[4, 5]
  • 52. Which is the concentric needle electrode recording uptake field (180 or 360 degree) for the duration parameter in a MUP Which is the concentric needle electrode recording uptake field (180 or 360 degree) for the spiky part of the MUP For Duration: about 2 mm, spherical. For Spiky part, about 0,5 mm, hemispherical[4, 5]
  • 53. Is it possible to make sure that you are stimulating muscle fibers directly and not intramuscular nerves in so called direct muscle stimulation (critical illness tests) Yes, by measuring the jitter. < 5usec if direct stimulation [7]
  • 54. Is it possible to make sure that you are stimulating muscle fibers directly and not intramuscular nerves in so called direct muscle stimulation (critical illness tests) Yes, by measuring the jitter. < 5usec if direct stimulation [7]
  • 55. In monopolar EMG recording you often see a small positive going signal on the end slope of the signal. What is this, and why do you not see that in concentric needle EMG This is a far field signal generated at the tendon. Since it is a far field potential it is recorded equally well with the tip as with the cannula in the concentric electrode and therefore cancelled. [4]
  • 56. With increasing force, the needle EMG amplitude (envelope amplitude) increases. Why? It is not the “size principle”, but a statistical phenomenon, with increasing chance of recording from the closest muscle fibers, with increasing force level.
  • 57. With increasing force, the needle EMG amplitude (envelope amplitude) increases. Why? It is not the “size principle”, but a statistical phenomenon with increasing chance of recording from the closest muscle fibers, with increasing force level.
  • 58. In concentric needle electrode recordings, one can sometimes obtain low amplitude MUP that looks “upside down”. Explanation? 1. Signals are mainly recorded by the cannula 2. Obtained close to the tendon
  • 59. In concentric needle electrode recordings, one can sometimes obtain low amplitude MUP that looks “upside down”. Explanation? 1. Signals are mainly recorded by the cannula 2. Obtained close to the tendon
  • 60. Reinnervation. In the early stage of collateral reinnervation (20 days) after a partial nerve lesion, you start to see MUPs with some jittering spikes. In general is the MUP “small” or “normal – slightly increased”? Collateral reinnervation takes place from a normal MU, so the reinnervated MU should be larger than a normal MU. We get small MUs, “nascent” MUPs only after complete nerve lesion followed by nerve regrowth.
  • 61. Reinnervation. In the early stage of collateral reinnervation (20 days) after a partial nerve lesion, you start to see MUPs with some jittering spikes. In general is the MUP “small” or “normal – slightly increased”? Collateral reinnervation takes place from a normal MU, so the reinnervated MU should be larger than a normal MU. We get small MUs, “nascent” MUPs only after complete nerve lesion followed by nerve regrowth.
  • 62. One month of increasing muscular weakness Background 21 yo man with slowly increasing symptoms since 1 month. Mainly muscle pain, weakness, especially in the arms. No diurnal variation. No trauma or other known trigger. Since previously asthma. On one occasion venous thrombosis in the left arm. Clinic: cranial nerves OK with the exception of neck flexor weakness. Arms and legs show muscular weakness proximally. Normal reflexes, Babinski plantar. Normal sensibility in arms and legs. Normal finger-nose test. Can't walk normally No skin abnormalities Lab: P-myoglobin=693 (24-77) P-Creatine Kinase=6050 (50-400)
  • 70. Ultrasonography: In the right Deltoid muscle there is partiel hyperecchogenic changes with an impression of increased interstitel vascularisation (as compared to m. EDC, m. Vastus lateralis and m. Tibialis anterior). Q6
  • 71. Summary: Clinical proximal weakness Neurography normal. EMG myopathic MUPs, IP and fibs Ultrasound: hyperechogenicity and increased vascularization in the deltoid. Muscle biopsy: fiber diameter variation, no grouping but other findings Question Likely diagnosis myositis MND in early stages virus Simvastatin side effect metabolic disorder
  • 72. Summary: Clinical proximal weakness Neurography normal. EMG myopathic MUPs, IP and fibs Ultrasound: hyperechogenicity and increased vascularization in the deltoid. Muscle biopsy: fiber diameter variation, no grouping but other findings Question Likely diagnosis myositis MND in early stages virus Simvastatin side effect metabolic disorder
  • 73. Q5 30 year old woman Past history: depression, ME/CFS, back problems Currently: A week with acute pain in the right and after a few days also the left shoulder/upper arm. Some pain in right leg. Weakness in painful areas. Rheumatologist assesses pat has reactive arthritis - gives steroids. Then neurologist consultant. Finds the diagnosis unclear and suggests neurophysiology
  • 74. Q5 Neurological examination Right-sided scapulae alata Bilateral weakness: Finger extension, wrist extension (and flexion). reduced sensibility over the right thumb and radially on the forearm Neurography: Motor MCV and F-responses: N. medianus and nervus ulnaris: Normal MCV and Normal F-laten Sensory SCS: Right n. cutaneous antebrachii lateralis: Low amplitude Normal findings forN. medianus (Volar, finger 1 and 3), n ulnaris ( finger 5),n. radialis, n. cutaneus antebrachii medialis
  • 75. Q: Most likely diagnosis: a. Parsonage Turner syndrome b. MND c. radiculopathy d. focal accessory damage e. “flail arm” Q5 EMG: Right m. biceps brachii, m. deltoideus bilat, left m. flexor carpi radialis and m. flexor carpi ulnaris. - NORMAL Right m. serratus anterior: Normal amplitude and duration of MUPs. Fibrillation potentials and positive sharp waves ++. Bilat m. flexor pollicis longus: 0 MUPs. Fibrillation potentials and positive sharp waves ++ Right m. extensor digitorum: Slight MUP changes Fibrillation potentials and positive sharp waves +.
  • 76. Reference List 1. Burke RE, Rudomin P, Zajac FEIII. Catch property in single mammalian motor units. Science. 1970;168:122-4. 2. Ertas M, Stalberg E, Falck B. Can the size principle be detected in conventional EMG recordings? Muscle Nerve. 1995;18:435-9. 3. Gydikov A, Kosarov D. Extraterritorial potential field of impulses from separate motor units in human muscles. Electromyography Clinical Neurophysiology. 1972;12:283-305. 4. Nandedkar SD, Sanders DB. Recording characteristics of monopolar EMG electrodes. Muscle Nerve. 1991;14:108-12. 5. Nandedkar SD, Sanders DB, Stålberg E. Selectivity of electromyographic recording techniques; a simulation study. Med Biol Eng Comput. 1985;23:536-40. 6. Stålberg E, Karlsson L. Simulation of the normal concentric needle electromyogram by using a muscle model. ClinNeurophysiol. 2001;112:464-71. 7. Stålberg E, Trontelj JV, Mihelin M. Electrical microstimulation with single-fiber electromyography: a useful method to study the physiology of the motor unit. Journal of Clinical Neurophysiology. 1992;9:105-19. 8. Stålberg E, Trontelj JV, Sanders DB. Single Fiber EMG. 3rd ed. Uppsala: Edshagen Publishing House; 2010.