SlideShare uma empresa Scribd logo
1 de 2
Baixar para ler offline
E1WF Ex d IIC / Ex e II
KCA472Series
Features and benefits:
• Brass indoor and outdoor cable gland for use in hazardous areas
• Suitable for circular, galvanised steel wire armour cables with
extruded polymeric bedding and oversheath
• Achieves IP66 seal onto cable and to enclosure with suitable sealing
washer or thread sealant
• Three part armour lock provides mechanical cable retention and
electrical continuity
• Inner PCP seal grips cable bedding and provides additional
ingress protection
• Suitable for most climatic conditions - weatherproof and waterproof
• Standard and Nickel plated versions available
• Full Installation Instructions supplied
Kit comprises:
E1WF Gland
Brass Earth Tag
Brass Locknut
Nylon Sealing Washer
PVC Shroud
(2 per kit up to and including 25mm size)
The E1WF weatherproof hazardous gland is a dual seal
high performance cable gland for steel wire armoured
cables.
EIWFPVCKCA47226062014
May be used in:
• Zones 0, 1  2 with Ex ia IIA, B  C equipment
• Zones 1  2 with Ex ib IIA, B  C equipment
• Zones 1  2 with Ex e II equipment
• Zones 2 with Ex nA II equipment
• Zone 21  22 with Ex tD A21
Where the cable is effectively filled,
may also be used in:
• Zones 1  2 with Ex d IIC equipment not containing a
source of ignition  with a volume less than 2000cm³
• Zones 1  2 with Ex d IIA  Ex d IIB equipment not
containing a source of ignition  with any volume
• Zone 1 with Ex d IIA  Ex d IIB equipment containing a
source of ignition  with a volume less than 2000cm³
• Zone 2 with Ex d IIA  Ex d IIB equipment containing a
source of ignition  with any volume
• Zone 2 with Ex nR II equipment
Specifications
Gland Kit Reference Cable Dimensions mm Gland Dimensions mm
Design Reference
Size
Qty per
Kit
Under Armour Ø (A) Overall Ø (B)
Armour
Wire Ø
Entry Thread
(D)
Thread
Length (E)
Protrusion
Length
(F)
Hexagon
Standard Nickel Plated Min Max Min Max A/F (G) A/C (H)
KCA472-51 KCA472-51V 16 2 3.8 8.7 8.0 13.2 0.9 M16 × 1.5 15 41 23.4 26.7
KCA472-71 KCA472-71V 20SS 2 3.8 8.7 8.0 13.2 0.9 M20 × 1.5 15 41 23.4 26.7
KCA472-52 KCA472-52V 20S 2 8.0 11.8 8.0 15.8 0.9 / 1.25 M20 × 1.5 15 43 25.7 29.2
KCA472-53 KCA472-53V 20 2 11.8 14.2 11.7 20.8 0.9 / 1.25 M20 × 1.5 15 43 30.5 34.0
KCA472-55 KCA472-55V 25 2 14.0 20.1 17.0 27.2 1.25 / 1.6 M25 × 1.5 15 48 37.6 42.2
KCA472-56 KCA472-56V 32 1 19.7 26.6 23.5 33.5 1.6 / 2.0 M32 × 1.5 15 53 47.2 53.6
KCA472-57 KCA472-57V 40 1 26.6 32.4 29.0 39.9 1.6 / 2.0 M40 × 1.5 15 56 56.4 61.5
KCA472-58 KCA472-58V 50S 1 32.4 38.4 38.0 46.2 2.0 / 2.5 M50 × 1.5 15 61 60.0 66.0
KCA472-59 KCA472-59V 50 1 38.4 44.3 39.5 52.6 2.0 / 2.5 M50 × 1.5 15 61 70.1 77.2
KCA472-60 KCA472-60V 63S 1 44.3 50.3 50.0 58.9 2.5 M63 × 1.5 15 64 75.0 83.0
KCA472-61 KCA472-61V 63 1 50.3 56.2 51.3 65.3 2.5 M63 × 1.5 15 64 80.0 87.4
KCA472-62 KCA472-62V 75S 1 56.2 62.2 62.0 71.6 2.5 M75 × 1.5 15 73 90.2 99.1
KCA472-63 KCA472-63V 75 1 62.2 68.1 62.5 78.0 2.5 M75 × 1.5 15 73 98.8 109.2
KCA472-64 KCA472-64V 85 1 68.0 74.0 68.0 88.0 3.15 M80 × 2.0 20 102 115.1 126.0
Technical Information:
Certified ΙΙ 2GD, Ex e ΙΙ  Ex d ΙΙC under ATEX directive 94/9/EC
Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7,
EN 61241-0, EN 61241-1
Certificate number Sira 02ATEX3092X
IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7,
IEC 61241-0, IEC 61241-1
Certificate number IECEx SIR 10.0071X
Service temperature range -60°C to +90°C
Prysmian Cables  Systems Limited,
Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK
Commercial Enquiries,
Sales Office Tel: 0845 767 8345,
International Sales Office Tel: +44 2380 295481
www.biconcomponents.co.uk

Mais conteúdo relacionado

Mais procurados

Mais procurados (18)

Siemon cat6 a cable data sheet upload
Siemon cat6 a cable data sheet  uploadSiemon cat6 a cable data sheet  upload
Siemon cat6 a cable data sheet upload
 
421-cable glands
421-cable glands421-cable glands
421-cable glands
 
Ellis Patents Emperor Single Cable Stainless Steel Cable Cleats
Ellis Patents Emperor Single Cable Stainless Steel Cable CleatsEllis Patents Emperor Single Cable Stainless Steel Cable Cleats
Ellis Patents Emperor Single Cable Stainless Steel Cable Cleats
 
Ellis Patents Emperor Stainless Steel Single Cable Cleats - Spec Sheet
Ellis Patents Emperor Stainless Steel Single Cable Cleats - Spec SheetEllis Patents Emperor Stainless Steel Single Cable Cleats - Spec Sheet
Ellis Patents Emperor Stainless Steel Single Cable Cleats - Spec Sheet
 
Prysmian E1W Brass Cable Glands - BICC, BICON
Prysmian E1W Brass Cable Glands - BICC, BICONPrysmian E1W Brass Cable Glands - BICC, BICON
Prysmian E1W Brass Cable Glands - BICC, BICON
 
Abtech SX1.5 Stainless Steel and Mild Steel Enclosures
Abtech SX1.5 Stainless Steel and Mild Steel EnclosuresAbtech SX1.5 Stainless Steel and Mild Steel Enclosures
Abtech SX1.5 Stainless Steel and Mild Steel Enclosures
 
E1W Brass Cable Glands - Prysmian KAA413 BICC BICON
E1W Brass Cable Glands - Prysmian KAA413 BICC BICONE1W Brass Cable Glands - Prysmian KAA413 BICC BICON
E1W Brass Cable Glands - Prysmian KAA413 BICC BICON
 
CW20 432LSF53 Prysmian BICON Aluminium Cable Glands
CW20 432LSF53 Prysmian BICON Aluminium Cable GlandsCW20 432LSF53 Prysmian BICON Aluminium Cable Glands
CW20 432LSF53 Prysmian BICON Aluminium Cable Glands
 
A2 LSF Brass Cable Glands - BICC, BICON, Prysmian
A2 LSF Brass Cable Glands - BICC, BICON, PrysmianA2 LSF Brass Cable Glands - BICC, BICON, Prysmian
A2 LSF Brass Cable Glands - BICC, BICON, Prysmian
 
Prysmian CW LSF Aluminium Cable Glands - BICC, BICON
Prysmian CW LSF Aluminium Cable Glands - BICC, BICONPrysmian CW LSF Aluminium Cable Glands - BICC, BICON
Prysmian CW LSF Aluminium Cable Glands - BICC, BICON
 
Ellis Patents Emperor Trefoil Stainless Steel Cable Cleats
Ellis Patents Emperor Trefoil Stainless Steel Cable CleatsEllis Patents Emperor Trefoil Stainless Steel Cable Cleats
Ellis Patents Emperor Trefoil Stainless Steel Cable Cleats
 
CMP B327-20 Zen Insulated Brass Cable Gland 12.5-20.9mm
CMP B327-20 Zen Insulated Brass Cable Gland  12.5-20.9mmCMP B327-20 Zen Insulated Brass Cable Gland  12.5-20.9mm
CMP B327-20 Zen Insulated Brass Cable Gland 12.5-20.9mm
 
Ellis Patents Emperor Stainless Steel Trefoil Cable Cleats - Spec Sheet
Ellis Patents Emperor Stainless Steel Trefoil Cable Cleats - Spec SheetEllis Patents Emperor Stainless Steel Trefoil Cable Cleats - Spec Sheet
Ellis Patents Emperor Stainless Steel Trefoil Cable Cleats - Spec Sheet
 
Fire Alarm & Fire Detection Cables For Building - Why Manage Service Cables I...
Fire Alarm & Fire Detection Cables For Building - Why Manage Service Cables I...Fire Alarm & Fire Detection Cables For Building - Why Manage Service Cables I...
Fire Alarm & Fire Detection Cables For Building - Why Manage Service Cables I...
 
Ellis Patents Emperor Trefoil ER19-23 - Cleat For Cables 19 to 23mm
Ellis Patents Emperor Trefoil ER19-23 - Cleat For Cables 19 to 23mmEllis Patents Emperor Trefoil ER19-23 - Cleat For Cables 19 to 23mm
Ellis Patents Emperor Trefoil ER19-23 - Cleat For Cables 19 to 23mm
 
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CEHigh Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE
 
Prysmian A220SS 423LSF-71 (3.5-8.5mm) LSF Brass BICON Gland Kits
Prysmian A220SS 423LSF-71 (3.5-8.5mm) LSF Brass BICON Gland KitsPrysmian A220SS 423LSF-71 (3.5-8.5mm) LSF Brass BICON Gland Kits
Prysmian A220SS 423LSF-71 (3.5-8.5mm) LSF Brass BICON Gland Kits
 
Lucy Zodion Photocell (PECU) SS12 - Miniature Street Lighting Photocell
Lucy Zodion Photocell (PECU) SS12 - Miniature Street Lighting PhotocellLucy Zodion Photocell (PECU) SS12 - Miniature Street Lighting Photocell
Lucy Zodion Photocell (PECU) SS12 - Miniature Street Lighting Photocell
 

Semelhante a Prysmian KCA472 E1FW Flameproof Bicon Gland Kit

Stahl 6014 sheet steel light fitting atex zone 1 zone 2 hazardous area ligh...
Stahl 6014 sheet steel light fitting   atex zone 1 zone 2 hazardous area ligh...Stahl 6014 sheet steel light fitting   atex zone 1 zone 2 hazardous area ligh...
Stahl 6014 sheet steel light fitting atex zone 1 zone 2 hazardous area ligh...
Thorne & Derrick International
 
3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...
3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...
3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...
Thorne & Derrick International
 

Semelhante a Prysmian KCA472 E1FW Flameproof Bicon Gland Kit (20)

Prysmian 474NP E1WXL Flameproof Bicon Gland Kits
Prysmian 474NP E1WXL Flameproof Bicon Gland KitsPrysmian 474NP E1WXL Flameproof Bicon Gland Kits
Prysmian 474NP E1WXL Flameproof Bicon Gland Kits
 
Prysmian 474NP- 03 Flameproof ATEX Cable Gland
Prysmian 474NP- 03 Flameproof ATEX Cable GlandPrysmian 474NP- 03 Flameproof ATEX Cable Gland
Prysmian 474NP- 03 Flameproof ATEX Cable Gland
 
hawke gland 501 423
hawke gland 501 423hawke gland 501 423
hawke gland 501 423
 
Hawke 501 421
Hawke 501 421Hawke 501 421
Hawke 501 421
 
CMP E2FW130 - ATEX Cable Gland - 114.2-123.3mm
CMP E2FW130 - ATEX Cable Gland - 114.2-123.3mmCMP E2FW130 - ATEX Cable Gland - 114.2-123.3mm
CMP E2FW130 - ATEX Cable Gland - 114.2-123.3mm
 
Hawke 501/421 Hazardous Area Cable Gland
Hawke 501/421 Hazardous Area Cable GlandHawke 501/421 Hazardous Area Cable Gland
Hawke 501/421 Hazardous Area Cable Gland
 
CW LSF Brass Cable Glands - Prysmian BICC BICON 422LSF NEW
CW LSF Brass Cable Glands - Prysmian BICC BICON 422LSF NEWCW LSF Brass Cable Glands - Prysmian BICC BICON 422LSF NEW
CW LSF Brass Cable Glands - Prysmian BICC BICON 422LSF NEW
 
Hawke 501/423 Hazardous Area Cable Gland
Hawke 501/423 Hazardous Area Cable GlandHawke 501/423 Hazardous Area Cable Gland
Hawke 501/423 Hazardous Area Cable Gland
 
Cap 011704.pdf
Cap 011704.pdfCap 011704.pdf
Cap 011704.pdf
 
E1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSF
E1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSFE1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSF
E1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSF
 
E1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSF
E1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSFE1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSF
E1W LSF Brass Cable Glands - BICC, BICON, Prysmian 421LSF
 
Hawke ICG 653/Universal Hazardous Area Cable Gland
Hawke ICG 653/Universal Hazardous Area Cable GlandHawke ICG 653/Universal Hazardous Area Cable Gland
Hawke ICG 653/Universal Hazardous Area Cable Gland
 
Stahl Lighting 6414 Light Fitting For Fluorescent Lamps - ATEX Zone 2 Hazardo...
Stahl Lighting 6414 Light Fitting For Fluorescent Lamps - ATEX Zone 2 Hazardo...Stahl Lighting 6414 Light Fitting For Fluorescent Lamps - ATEX Zone 2 Hazardo...
Stahl Lighting 6414 Light Fitting For Fluorescent Lamps - ATEX Zone 2 Hazardo...
 
Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...
Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...
Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...
 
Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...
Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...
Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...
 
Stahl 6014 sheet steel light fitting atex zone 1 zone 2 hazardous area ligh...
Stahl 6014 sheet steel light fitting   atex zone 1 zone 2 hazardous area ligh...Stahl 6014 sheet steel light fitting   atex zone 1 zone 2 hazardous area ligh...
Stahl 6014 sheet steel light fitting atex zone 1 zone 2 hazardous area ligh...
 
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE NEW
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE NEWHigh Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE NEW
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE NEW
 
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE
High Voltage Cable Glands - Prysmian BICON CW SWA Brass Glands 419CE
 
3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...
3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...
3M Cold Shrink High Voltage Cable Joints and Cable Terminations, Network Rail...
 
Hawke 501/414 Hazardous Area Cable Glands
Hawke 501/414 Hazardous Area Cable GlandsHawke 501/414 Hazardous Area Cable Glands
Hawke 501/414 Hazardous Area Cable Glands
 

Mais de Thorne & Derrick International

Mais de Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

Último

Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
WSO2
 

Último (20)

Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
 
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering Developers
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor Presentation
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 

Prysmian KCA472 E1FW Flameproof Bicon Gland Kit

  • 1. E1WF Ex d IIC / Ex e II KCA472Series Features and benefits: • Brass indoor and outdoor cable gland for use in hazardous areas • Suitable for circular, galvanised steel wire armour cables with extruded polymeric bedding and oversheath • Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant • Three part armour lock provides mechanical cable retention and electrical continuity • Inner PCP seal grips cable bedding and provides additional ingress protection • Suitable for most climatic conditions - weatherproof and waterproof • Standard and Nickel plated versions available • Full Installation Instructions supplied Kit comprises: E1WF Gland Brass Earth Tag Brass Locknut Nylon Sealing Washer PVC Shroud (2 per kit up to and including 25mm size) The E1WF weatherproof hazardous gland is a dual seal high performance cable gland for steel wire armoured cables.
  • 2. EIWFPVCKCA47226062014 May be used in: • Zones 0, 1 2 with Ex ia IIA, B C equipment • Zones 1 2 with Ex ib IIA, B C equipment • Zones 1 2 with Ex e II equipment • Zones 2 with Ex nA II equipment • Zone 21 22 with Ex tD A21 Where the cable is effectively filled, may also be used in: • Zones 1 2 with Ex d IIC equipment not containing a source of ignition with a volume less than 2000cm³ • Zones 1 2 with Ex d IIA Ex d IIB equipment not containing a source of ignition with any volume • Zone 1 with Ex d IIA Ex d IIB equipment containing a source of ignition with a volume less than 2000cm³ • Zone 2 with Ex d IIA Ex d IIB equipment containing a source of ignition with any volume • Zone 2 with Ex nR II equipment Specifications Gland Kit Reference Cable Dimensions mm Gland Dimensions mm Design Reference Size Qty per Kit Under Armour Ø (A) Overall Ø (B) Armour Wire Ø Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon Standard Nickel Plated Min Max Min Max A/F (G) A/C (H) KCA472-51 KCA472-51V 16 2 3.8 8.7 8.0 13.2 0.9 M16 × 1.5 15 41 23.4 26.7 KCA472-71 KCA472-71V 20SS 2 3.8 8.7 8.0 13.2 0.9 M20 × 1.5 15 41 23.4 26.7 KCA472-52 KCA472-52V 20S 2 8.0 11.8 8.0 15.8 0.9 / 1.25 M20 × 1.5 15 43 25.7 29.2 KCA472-53 KCA472-53V 20 2 11.8 14.2 11.7 20.8 0.9 / 1.25 M20 × 1.5 15 43 30.5 34.0 KCA472-55 KCA472-55V 25 2 14.0 20.1 17.0 27.2 1.25 / 1.6 M25 × 1.5 15 48 37.6 42.2 KCA472-56 KCA472-56V 32 1 19.7 26.6 23.5 33.5 1.6 / 2.0 M32 × 1.5 15 53 47.2 53.6 KCA472-57 KCA472-57V 40 1 26.6 32.4 29.0 39.9 1.6 / 2.0 M40 × 1.5 15 56 56.4 61.5 KCA472-58 KCA472-58V 50S 1 32.4 38.4 38.0 46.2 2.0 / 2.5 M50 × 1.5 15 61 60.0 66.0 KCA472-59 KCA472-59V 50 1 38.4 44.3 39.5 52.6 2.0 / 2.5 M50 × 1.5 15 61 70.1 77.2 KCA472-60 KCA472-60V 63S 1 44.3 50.3 50.0 58.9 2.5 M63 × 1.5 15 64 75.0 83.0 KCA472-61 KCA472-61V 63 1 50.3 56.2 51.3 65.3 2.5 M63 × 1.5 15 64 80.0 87.4 KCA472-62 KCA472-62V 75S 1 56.2 62.2 62.0 71.6 2.5 M75 × 1.5 15 73 90.2 99.1 KCA472-63 KCA472-63V 75 1 62.2 68.1 62.5 78.0 2.5 M75 × 1.5 15 73 98.8 109.2 KCA472-64 KCA472-64V 85 1 68.0 74.0 68.0 88.0 3.15 M80 × 2.0 20 102 115.1 126.0 Technical Information: Certified ΙΙ 2GD, Ex e ΙΙ Ex d ΙΙC under ATEX directive 94/9/EC Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1 Certificate number Sira 02ATEX3092X IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1 Certificate number IECEx SIR 10.0071X Service temperature range -60°C to +90°C Prysmian Cables Systems Limited, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UK Commercial Enquiries, Sales Office Tel: 0845 767 8345, International Sales Office Tel: +44 2380 295481 www.biconcomponents.co.uk