Scaling API-first – The story of a global engineering organization
Railway Electrification Components and Systems Guide
1. Components and Systems for the
Electrification of Railway Lines.
PFISTERER
RAIL SYSTEMS
Connectors, Clamps, Compensating Devices, Insulators
and Safety Equipment for Electrification of Rail
2. PFISTERER provides perfect solutions for railway systems. The technology developed in-house for the
production of safe and reliable railway electrification material offers a comprehensive program of clamps
and compensating devices. This also includes all necessary auxiliary equipment and tools.
We have extended this line to include a broad range of silicon and section insulators, as well as
catenary geometry measuring devices.
All these products are complemented by a full range of voltage detectors and grounding equipment.
PFISTERER RAIL SYSTEMS offer you connectors and systems for the electrification of railway lines:
Hangers and Connectors
Insulators and Suspensions
Tools
TENSOREX®
System
Safety Equipment
Welcome to the PFISTERER RAIL
SYSTEMS Centre of Competence.
3. PFISTERER has been supplying products for railway
electrification for more than 30 years which has
shaped our product program. Our products have
been installed worldwide in subway, tramway and
high-speed lines becoming a reference for Railway
Administrations.
The length of the subway, tramway and high-speed
rail networks will more than double worldwide in
the next 10 years due to an expanding market and
changes in consumer demands. PFISTERER will be
present in this growth supplying not only products
but knowledge as well.
Our products are adapted to customer needs provi-
ding application and design support.
For example our patented TENSOREX®
system has
demonstrated a definite improvement in catenary
systems, introducing an innovative solution for the
mechanical compensation of catenary cables, increa-
sing efficiency and substantially reducing mainte-
nance.
Our hangers and connectors have been success-
fully installed by major Railway Administrations both
in local tramway, and in high-speed lines satisfying
demanding requirements and achieving a high gra-
de of performance.
Nowadays, silicon insulators are becoming more
and more accepted due to their advantages: custo-
mized fittings, light weight, simple installation.
And in safety equipment, we have increased our
range including variants to cover all the different
operating voltages of the Railway Administrations.
Excellent Products for Excellent Means of Transport.
7. 7www.pfisterer.com
Current Carrying Dropper
Droppers are used for the full current carrying suspension / connection from / to the
contact wire on the messenger wire
I
CatenaryFittings
PFISTERER Rail Systems
No. Description Material .
PE.HC 107/CU70.10 Current Carrying Dropper
305.859.002.70 Dropper clamp for CW and 65.81 mm² MW CuNi2Si
625.012.P10 Thimble Nylon
TAI M10x30 M10 Screw A2
ADI M10 Washer A2
625.012.41 Splice Copper
305.312.002 Splice Copper
Application pictures:
Conductive Dropper
8. 8 www.pfisterer.com
I
CatenaryFittings
PFISTERER Rail Systems
Steady arm clamps
This clamp is used to mount the contact wire with the steady arm with bolts.
Option: hexagonal bolts.
Material:
CuNi2Si
A2 screws
No. No. Contact wire
cross section
Pivot outside
diameter
Pivot inside
diameter
Tightening
Torque
Weight References
(mm) (mm) (Nm) (kg)
304 741 001 G-1T Ri80 - Ri150 24.5 16 38 0.198 UK: NETWORK RAIL
ADIF: 74.024.400
SBB, CHINA
304 742 001 G-1TA Ri80 - Ri150 16 10.5 20 0.175 AVE
Application pictures:
G-1T on high speedPivot for G-1T Pivot for G-1TA
9. 9www.pfisterer.com
Contact wire Z-cable anchor clamps
This clamp is used to anchor the contact wire to the Z-cable.
Material:
CuNi2Si
Screws in A2
No. No. Contact wire
cross section
Anchoring cable
cross section
Number of
screws
Tightening
Torque
Weight References
(mm2
) (Nm) (kg)
325 102 001 GPF 70/150 Ri 80 - 150 70 - 150 2 65 0.44 UK: NETWORK RAIL
AVE
- GPF 70/150M Ri 80 - 150 70 - 150 1 65 0.22 -
I
CatenaryFittings
PFISTERER Rail Systems
Application pictures:
Z-cable anchorage
10. 10 www.pfisterer.com
I
CatenaryFittings
PFISTERER Rail Systems
High Mechanical Working Load Clamps
This clamp, also know as an „elephant clamp“, is used for high mechanical load applica-
tions providing a full current connection as:
■ Messenger wire anchor cable (Z-cable)
■ Fixed point
■ Stitch wire
Material:
CuNi2Si
Screws in A2
No. No. Cable cross
section 1
Cable cross
section 2
Main cable
cross section
Derived cable
cross section
Tightening
Torque
Weight References
(mm2
) (mm2
) (mm2
) (mm2
) (Nm) (kg)
332 321 003 KP 25/70 25 - 70 25 - 70 25 / 70 25 / 70 20 0.362 DB: Ebs 07.42.42 Bl.1
332 321 005 KP 35/120 35 - 120 35 - 120 25 / 95 50 / 95 20 0.362 NETWORK RAIL
AVE
- KP 35/120# - - 70 / 120 70 / 120 20 0.362 AVE
Application pictures:
Fixed point clamp Stitch wire clamp Messenger wire anchor clamp
11. 11www.pfisterer.com
Railway Silicone Composite Insulators
Composite silicone insulators for 25 kV lines with the following advantages:
■ Light weight
■ Anti-vandalism
■ Self cleaned with rain
■ Suitable for polluted areas
■ Easy to store and handle
■ Manufactured according to IEC standards
Material:
Steel end fittings
Silicone insulators with fiberglass rod core
No. Power frequency with-
stand voltage (wet)
Lightning impulse
withstand voltage
Arcing distance Minimum creepage
distance
Specified mechanical
load (SML)
Number of
sheds
Approx.
weight
1 min (kV) (mm) (mm) (kN) (kg)
144 034 001 115 250 461 1238 160 5/6 2.92
144 034 051 95 250 461 1238 135 10 3.1
I
CatenaryFittings
PFISTERER Rail Systems
Application pictures:
PFISTERER Insulators with TENSOREX
12. 12 www.pfisterer.com
I
CatenaryFittings
PFISTERER Rail Systems
Contact wire splice, riveted
The riveted overhead traction wire splice is used to connect grooved overhead traction
wire with full tension.
It is fitted hydraulically with size III compression units.
Material:
High strength copper alloy clamping jaws CuNiSi
Copper rivet
Bare surface
No. No. Contact wire cross
section
Appropriate insert
for compressing
Appropriate insert
for removing
Number of
rivets
Weight References
(kg)
302 391 391 - Ri65 / 80 / 100 / 120 302 346 346 (DB 4 N) 302 345 345 (DB 4 L) 4 0.37 DB 07.42.23
- 302 910 910 65 / 120 - - 6 - -
Application pictures:
Contact wire splice
13. 13www.pfisterer.com
Contact wire splice, screw-in
The screwed on overhead traction wire splicee is used to connect grooved overhead
traction wires with full tension.
Material:
High strength copper alloy CuNiSi clamping jaws
A2 screws
Bare surface
No. No. Contact wire cross
section
Tightening Torque Weight References
(Nm) (kg)
302 537 537 - Ri80 - Ri120 20 0.5 UK Rail: 121/202/002
- 302 537 537 IT 80 / 120 20 0.9 RFI 774/215
Application pictures:
Contact wire splice
I
CatenaryFittings
PFISTERER Rail Systems
14. 14 www.pfisterer.com
PFISTERER Rail Systems
I
CatenaryFittings
Earth stanchion clamp
The earth stanchion clamp has been developed to tension conductor wires on
overhead catenary systems.
Material:
High strength aluminium alloy
No. Wire Diameter Working Load
(mm) (kN)
244 340 320 9.0 - 24.5 300
Wedge clamp
No. BR References Wire Diameter Working Load Conductor
Wire
PADS No.
(mm) (kN)
406 594 594 A 9.0 - 10.7 90 Copper or Steel 091/002341
406 594 595 B 10.8 - 12.5 90 Copper or Steel 091/002344
406 594 597 C 14.4 - 16.1 90 Copper or Steel 091/002345
406 598 602 D 16.2 - 18.2 90 Aluminium 091/002346
406 598 604 E 20.5 - 22.5 90 Aluminium 091/002347
406 594 003 F 18.3 - 20.4 160 Copper or Steel 091/002348
406 598 598 AS 9.0 - 10.7 90 Aluminium 091/002343
406 598 599 AL 10.8 - 12.5 90 Copper or Steel 091/002342
The wedge clamps have been developed to tension conductor wires on overhead
catenary systems.
Material:
High strength aluminium alloy
Wedge clamp body
No. for Wire Diameter
up to
(mm)
438 158 001 9.0 - 24.5
438 158 002 24.5 - 32
15. 15www.pfisterer.com
Bolt Electrical Connection Clamps
This clamp is used to provide a full current connection between:
■ Messenger wire and feeding cable
■ Contact wire and feeding cable
Material:
Brass
Screws in A2
No. Messenger wire
cross section
Feeder cable cross
section
Contact wire cross
section
Tightening Torque Weight References
(mm2
) (mm2
) (mm2
) (Nm) (kg)
HC 106 VM 70 - 120 70 - 120 HC 107 20 0,5
Application pictures:
PFISTERER Rail Systems
I
CatenaryFittings
CW and MW connections in Jumper
16. 16 www.pfisterer.com
PFISTERER Rail Systems
TENSOREX spring charged tensioning system
Modern railways place new demands on tensioning systems: High-speed lines with
numerous tunnels require tensioning devices that easily integrate in the tunnel geometry.
To an ever increasing extent, urban transport systems are being designed with a focus
on aesthetic aspects and require tensioning devices that blend inconspicuously into the
overall scheme. TENSOREX, the spring-operated tensioning system offers solutions for
both applications.
Further advantages:
■ Use of spring tensioning devices for constant tension in contact wires and/or
bearer cables
■ Suitable for temperature ranges and many span lengths
■ Minimum storage and maintenance costs
■ Constant tension over entire length of lines
■ Highly accurate
■ Suitable for all types of catenary poles
■ Easy to install - reduced manpower
■ Moving parts inaccessible - no protective cage required
■ Optional equipment: Telemonitoring system on request
TENSOREX C+
TENSOREX C+ is a patented, automatic tensioning system that uses the force of a coil
spring to constantly tension the railway catenary and/or bearer cable. It therefore effec-
tively compensates the expansion caused by fluctuating daytime and nighttime tempera-
tures as well as the change in the seasons while keeping the tension at a constant level.
The TENSOREX C+ features a particularly compact design, making it virtually inconspicu-
ous from an urban planning point of view.
Other versions are available on request.
The components required for mounting on catenary posts can be supplied on request.
No. Description PADS No. Regulating length Tensile force
(mm) (kN)
000700889102 Tensorex TRC+ 375/1150 091/029011 375 11.3
000700890102 Tensorex TRC+ 375/835 091/029012 375 8.195
000700891102 Tensorex TRC+ 375/1985 091/029013 375 19.495
000700680102 Tensorex TRC+ 375/1125 091/029014 375 11
000700490102 Tensorex TRC+ 375/2250 091/029015 375 22
000700892102 Tensorex TRC+ 375/1425 091/029016 375 14
000700893102 Tensorex TRC+ 375/1225 091/029017 375 12
000700894102 Tensorex TRC+ 375/875 091/029018 375 8.56
000700895102 Tensorex TRC+ 375/1215 091/029019 375 11.9
000700896102 Tensorex TRC+ 375/2085 091/029020 375 20.46
000700881102 Tensorex TRC+ 375/1150 091/029021 1000 11.3
000700885102 Tensorex TRC+ 1000/835 091/029022 1000 8.195
000700878102 Tensorex TRC+ 1000/1985 091/029023 1000 19.495
000700886102 Tensorex TRC+ 1000/1125 091/029024 1000 11
000700879102 Tensorex TRC+ 1000/2250 091/029025 1000 22
000700882102 Tensorex TRC+ 1000/1425 091/029026 1000 14
000700883102 Tensorex TRC+ 1000/1225 091/029027 1000 12
000700887102 Tensorex TRC+ 1000/875 091/029028 1000 8.56
000700884102 Tensorex TRC+ 1000/1215 091/029029 1000 11.9
000700880102 Tensorex TRC+ 1000/2085 091/029030 1000 20.46
0007006871.104 Tensorex TRC+ 1000/1680 091/070132 1000 16
000700897104 Tensorex TRC+ 1000/1320 091/070133 1000 13
0007006731.104 Tensorex TRC+ 750/1680 091/070157 750 16
0007010441.104 Tensorex TRC+ 450/1680 091/070158 450 16
000700687104 Tensorex TRC+ 1000/1680 091/070159 1000 16
000700672104 Tensorex TRC+ 750/1320 091/070186 750 13
000700671104 Tensorex TRC+ 450/1320 091/070187 450 13
000700673104 Tensorex TRC+ 750/1680 091/070188 750 16
000701044104 Tensorex TRC+ 450/1680 091/070189 450 16
I
CatenaryFittings
17. 17www.pfisterer.com
SICON Power Feed Range
SICON “Power Feed Range” completely eliminates the need for compression tooling
which results in:
■ Less weight for the engineers to transport down the track
■ Improved trackside productivity
■ Consistent level of installation regardless of the experience of the operator due to the
use of stepless shearbolt technology
■ No more concerns about tooling calibration
■ Can be used with copper and aluminium conductors therefore no need for
bi-metallic connectors
■ Can be used for multiple conductor sizes
Transformer Connector
No. Width across
flats
PADS No.
332 594 003 8 054/212152
Rectifier Connector
No. Width across
flats
PADS No.
332 612 016 8 054/212157
332 612 017 8 054/212158
No. Al Al Cu Cu
(mm2
) (mm2
) (mm2
) (mm2
)
332 612 016 300 - 630 300 - 630 300 - 630 300 - 630
332 612 017 300 - 630 300 - 630 300 - 630 300 - 630
PFISTERER Rail Systems
II
CableandTrackConnections
No. Al Al Cu Cu
(mm2
) (mm2
) (mm2
) (mm2
)
332 594 003 800 - 1000 800 - 1000 800 - 1000 800 - 1000
18. 18 www.pfisterer.com
II
CableandTrackConnections
PFISTERER Rail Systems
Busbar Connector
No. Width across
flats
PADS No.
332 594 004 8 054/212154
Hook Switch Connector
No. Palm angle Width
across flats
PADS No.
332 594 005 30° 8 054/212159
No. Al Al Cu Cu
(mm2
) (mm2
) (mm2
) (mm2
)
332 594 004 800 - 1000 800 - 1000 800 - 1000 800 - 1000
No. Al Al Cu Cu
(mm2
) (mm2
) (mm2
) (mm2
)
332 594 005 800 - 1000 800 - 1000 800 - 1000 800 - 1000
19. 19www.pfisterer.com
No. Palm angle Width across
flats
PADS No.
332 594 006 35° 8 054/212160
Conductor Rail Connector
Through Splice
No. Width across
flats
PADS No.
332 645 010 8 054/212169
PFISTERER Rail Systems
II
CableandTrackConnections
No. Al Al Cu Cu
(mm2
) (mm2
) (mm2
) (mm2
)
332 594 006 800 - 1000 800 - 1000 800 - 1000 800 - 1000
No. Al Al Cu Cu
(mm2
) (mm2
) (mm2
) (mm2
)
332 645 010 800 - 1000 800 - 1000 800 - 1000 800 - 1000
23. 23www.pfisterer.com
PFISTERER Rail Systems
II
CableandTrackConnections
RSC-T, new insulation piercing tap-off connector for
earth connection cables on railway systems
Advantages
■ easy assembly without stripping the cable insulation
■ reduced installation time
■ no special tool required
■ no cutting of main conductor necessary
■ tested according IEC 61284:1997-09 (Class B)
■ cover protects agains accidental contact, dust and moisture
■ consistent and reliable connection due to shear bolt technology
■ PADS approval PA05/06096
■ PFISTERER part code 331 846 001
■ 4 pieces per box
■ PADS Number 0091/070198
Product description External diameter of
the conductor
External diameter of
the cable
Cross section
(mm) (mm) (mm²)
Main conductor 19/4.22 21.1 25 265.8
Branch conductor 19/3.25 16.25 20 157.5
On railway systems all trackside equipment that has the potential to become live has
to be earthed. For this purpose, the earth connection cable must connect properly the
ground potential. With RSC-T this is possible without stripping the cable insulation.
25. 25www.pfisterer.com
II
CableandTrackConnections
PFISTERER Rail Systems
MV-CONNEX Separable Connectors, Size 3-S,
Um
= 52 kV, IN
= 1250 A
Standard article no.
■ for RM-conductor (stranded circular) of aluminium or copper
■ for single core cable with copper wire shield without armouring
■ with sealing system (bell flange seal and shrink tubing)
■ for indoor and outdoor applications
■ not soil-resistant and not offshore-proof
■ Packaging unit: set with three separable connectors
■ Voltage taps that are not connected to a voltage display system, must be earthed
for size 3-S
■ rotatable flange
■ offshore version on request
■ 3-core version on request
No. No. Max. operating
voltage
for cable
cross section
for diameter
over conductor
for diameter
over PE/VPE
insulation
Um
(kV) (mm2
) (mm) Ø (mm)
850 350 120 - 52 120 11.5 - 13.7 32.0 - 36.0
850 350 150 - 52 150 13.5 - 15.7 36.0 - 39.5
850 350 185 - 52 185 15.0 - 17.2 36.0 - 39.5
850 350 240 - 52 240 17.5 - 19.7 38.0 - 41.0
850 350 300 - 52 300 19.5 - 21.7 38.0 - 41.0
850 350 400 - 52 400 22.6 - 24.8 40.0 - 43.0
850 350 500 - 52 500 25.4 - 27.6 43.5 - 46.0
- 870 350 630 52 630 28.9 - 31.1 47.5 - 50.0
26. 26 www.pfisterer.com
PFISTERER Rail Systems
SafetyEquipment
III
Voltage Detectors KP-Test 5H
The KP-Test 5H capacitive voltage detector has universal high voltage application for
nominal voltages from 30 to 420 kV. It indicates the presence of operating voltage when
brought into contact with the conductor. The KP-Test 5H voltage detector is distinguished
by its high level of user-friendliness and user safety.
Technical description:
■ Available for different ranges of nominal voltages from 30 to 420 kV
■ Can be used in rain and snow
■ Particularly loud, integrated audible signal for reliable voltage tests even in a
noisy environment
■ Extremely bright LEDs in clear layout to prevent confusion
■ Maximum resistance to interference fields through the use of a high-quality
contact electrode extension
■ Extensive self-test functions at switch-on
■ Available separately for use with existing insulating poles
■ Available complete with suitable insulating poles in any overall length or carrying length
■ Insertion depth Ai
= 898 mm
■ Nominal frequency 50 Hz, optional 60 Hz
The KP-Test 5H is constructed and type-tested to Standard IEC 61243-1.
The KP-Test 5H Series voltage detector is also available with a carrying case on request.
Other versions with deviating nominal voltages, ranges of nominal voltage, frequencies
and languages are available on request.
No. Version Nominal voltage Insulating
length
Total length Transporting
length
Number of
insulating poles
Suitable bag
Un
(kV) LI
(mm) LG
(mm) LT
(mm)
930 250 001 0136 33 - 66 kV / 50 Hz 975 2478 1485 1 B5
930 250 001 0167 66 - 132 kV / 50 Hz 1802 3700 1855 2 B2
930 250 001 0048 110 kV / 50 Hz 1802 3700 1855 2 B2
930 250 001 0008 110 - 220 kV / 50 Hz 3220 5118 2050 3 B2
930 250 001 0078 220 - 420 kV / 50 Hz 3850 5748 2050 3 B2
930 250 001 0038 400 kV / 50 Hz 3850 5748 2050 3 B2
27. 27www.pfisterer.com
PFISTERER Rail Systems
III
SafetyEquipment
Voltage Detectors for Railway Systems
Electric railway systems around the world are operated with different voltage systems.
PFISTERER can supply voltage detectors for all common voltage systems.
■ 15 kV at 16.7 Hz
■ 25 kV at 50 Hz
■ 1500 V DC
■ 3000 V DC
■ Voltage supply for trolley lines
■ Voltage supply for urban rail systems with third rail
Depending on type, our voltage detectors are suitable for use on railway catenaries and
power lines as well as on switchgear.
Voltage Detectors KP-Test 5R 25 kV for Catenaries
The KP-Test 5R 25 kV 50 Hz capacitive voltage detector designed for use on railway
catenaries. It indicates the presence of operating voltage when brought into contact with
the conductor.
Technical Description:
■ Bright LEDs for clear recognition
■ Particularly loud, integrated audible signal
■ Extensive self-test functions at switch-on
■ Contact electrode in hook form with contact pin for optimum contact with the catenary
■ For single-phase networks
Versions in other languages or with other signal mode are available on request.
No. Version Total length Transporting
length
Suitable bag Carrying bag
included
LG
(mm) LT
(mm)
930 300 001 0007 4795 2460 B3 -
28. 28 www.pfisterer.com
PFISTERER Rail Systems
SafetyEquipment
III
Voltage Detectors KP-Test 5R 25 kV for Catenaries, Separable
The KP-Test 5R 25 kV 50 Hz capacitive voltage detector designed for use on railway
catenaries. It indicates the presence of operating voltage when brought into contact with
the conductor.
For transport in service vehicles the voltage detector can be dismantled into five separate
components.
Technical Description:
■ Bright LEDs for clear recognition
■ Particularly loud, integrated audible signal
■ Extensive self-test functions at switch-on
■ Separable contact electrode in hook form with point-contact for optimum contact
with the catenary
■ For single-phase networks
Versions in other languages or with other signal mode are available on request.
No. Version Total length Transporting
length
Suitable bag Carrying bag
included
LG
(mm) LT
(mm)
930 300 601 0009 4785 1100 B1 -
29. 29www.pfisterer.com
PFISTERER Rail Systems
III
SafetyEquipment
Voltage Detectors KP-Test 5R DC
The KP-Test 5R DC double-pole voltage detector is designed for use on the catenary
systems of DC voltage railways. It indicates the presence of operating voltage when
brought into contact with the conductor. With its extensive, integrated self-tests, the
KP-Test 5R DC voltage detector ensures maximum user safety.
Technical description:
■ Double-pole type for the catenary systems of DC voltage railways with nominal
voltages between 500 and 4,000 V DC
■ Second pole designed with practical magnetic connection to rail
■ Hook-type contact electrode with high-quality contact pin for optimum contact
■ Self-test at switch-on also checks the connecting cable
■ Can be used in rain and snow
■ Integrated audible signal for reliable voltage tests even in a noisy environment
■ Extremely bright LEDs in clear layout to prevent confusion
■ Induced AC voltage signal detection
■ Voltage testing possible even with a high proportion of leakage current on
disconnected contact wires
■ Available separately without insulating pole
■ Available separately without insulating pole, but with additional adapters
■ Available complete with three-piece insulating pole (poles RP1 and UP; total length
about 5,000 mm), or five-piece insulating pole (poles RP2, RP3, RP4 and UP; total
length about 4,880 mm)
■ Available with convenient carrying case
Other versions with deviating nominal voltages, ranges of nominal voltage and languages
are available on request.
No. Version Nominal Voltage DC Transporting length Number of insulating
poles
Suitable bag
Un
(V) LT
(mm)
930 350 001 0097 650 - 750 2450 2 B3
930 350 001 0085 1500 2450 2 B3
930 350 001 0077 3000 2450 2 B3 (incl.)
30. 30 www.pfisterer.com
PFISTERER Rail Systems
SafetyEquipment
III
Voltage Detectors KP-Test 5R DC dual
The KP-Test 5R DC dual double-pole voltage detector is similar in design to the
KP-Test 5R DC. In addition, this voltage detector can be switched between two nominal
voltage ranges in two steps. This allows a larger system range to be covered even when
there is a high proportion of leakage current.
The KP-Test 5R DC dual has two selectable voltage steps.
Step 1:
■ Selected by briefly pressing the On button
■ LED indicator: 1 x green
Step 2:
■ Selected by pressing and holding the On button
■ LED indicator: 2 x green
Deliberate voltage level selection at switch-on and the related self-test ensure that the
KP-Test 5R DC dual displays safe, clear indications.
Technical description:
■ Double-pole type for the catenary systems of DC voltage railways with nominal
voltages between 500 and 4,000 V DC
■ Second pole designed for practical magnetic connection to rail
■ Voltage range selectable
■ Hook-type contact electrode with high-quality contact pin for optimum contact
■ Self-test at switch-on also checks the connecting cable
■ Can be used in rain and snow
■ Integrated audible signal for reliable voltage tests even in a noisy environment
■ Extremely bright LEDs in clear layout to prevent confusion
■ Induced AC voltage signal detection
■ Voltage testing possible even with a high proportion of leakage current on
disconnected contact wires
■ Available separately without insulating pole
■ Available separately without insulating pole, but with additional adapter
■ Available complete with three-piece insulating pole (poles RP1 and UP; total length
about 5,000 mm), or five-piece insulating pole (poles RP2, RP3, RP4 and UP; total
length about 4,880 mm)
■ Available with convenient carrying case
Other versions with deviating nominal voltages, ranges of nominal voltage and languages
are available on request.
No. Version Nominal voltage
DC Level I
Nominal voltage
DC Level II
Transporting
length
Number of insulating
poles
Suitable bag
Un
(V) Un
(V) LT
(mm)
930 350 501 0007 600 1200 1111 - B1
930 350 501 0008 600 1200 2450 2 B3
930 350 501 0009 600 1200 1111 4 B1
930 350 501 0010 750 1,500 1111 - B1
930 350 501 0011 750 1,500 2450 2 B3
930 350 501 0012 750 1,500 1111 4 B1
31. 31www.pfisterer.com
PFISTERER Rail Systems
Voltage Detectors KP-Test 5 DC
The KP-Test 5 DC Double-pole voltage detector is suitable for use on the switchgear of
DC voltage railways as well as railway systems with a third rail. It indicates the presence
of operating voltage when brought into contact with the conductor. With its extensive,
integrated self-tests, the KP-Test 5 DC voltage detector ensures maximum user safety.
It also provides maximum ease of operation.
Technical description:
■ Double-pole type for use on the switchgear of DC railways as well as on railways with
a third rail and nominal voltages between 500 and 4,000 V DC
■ Self-test at switch-on also checks the connecting cable
■ Can be used in rain and snow
■ Integrated audible signal for reliable voltage tests even in a noisy environment
■ Extremely bright LEDs in clear layout to prevent confusion
■ Induced AC voltage signals detected
Other versions with deviating nominal voltages, ranges of nominal voltage and languages
are available on request.
No. Version Nominal voltage Total length Transporting
length
Cable length Suitable bag
UN
LG
(mm) LT
(mm) (mm)
930 370 001 0020 750 V DC 815 572 1000 A1
III
SafetyEquipment
32. 32 www.pfisterer.com
PFISTERER Rail Systems
SafetyEquipment
III
Rail earthing clamps
PFISTERER offers a range of rail earthing clamps for railway lines.
Rail earthing clamps R50
This rail earthing clamp is suitable for all rail base gauges. The small overall height of 35
mm below the rail base makes removal of gravel unnecessary. A separate handle allows
easy placing of the clamp and protects the earth wire connection. When tightening the
clamp, the annular cutting edge cuts through layers of dirt and oxide, thus ensuring relia-
ble contact. The counter-surface, a hardened metal tip, is spring-mounted and insulated.
The clamp is therefore flame-resistant in the event of a short circuit.
No. Max. cross
section of
connected
cable
Max. short-
circuit current
With ratchet Weight DB drawing-
no.
(mm2
) Ik
0,12 s (A) mit Ratsche (g)
363 322 005 50 40000 ■ 2128 3 Ebgw 01.13
363 322 006 50 40000 - 1706 -
Rail earthing clamps R51
This rail earthing clamp is designed as an earthing magnet for use on trolley lines.
No. Max. cross section of
connected cable
Max. short-circuit
current
Weight
(mm2
) Ik
1 s (A) (g)
364 901 001 70 13800 5000
Rail earthing clamps R52
These rail earthing clamps are suitable for use on grooved rails.
No. Max. cross section of
connected cable
Max. short-circuit
current
Weight
(mm2
) Ik
0,12 s (A) (g)
364 868 001 50 40000 858
33. 33www.pfisterer.com
PFISTERER Rail Systems
IV
MonitoringEquipment
Contact Wire Laser Measuring Device
This unit is used to measure the height and stagger of the contact wire
using laser measuring technology.
Application:
■ Height, stagger and cant measuring
Technical description:
■ Laser measures
■ No need touching wires
■ Used in any weather conditions
■ Bluetooth Smart 4.0
■ Cant gauge
■ Easy transportation
No. ID-Code Track width Measuring range,
on the stagger (MR)
Data information
(mm) (mm)
304 132 001 GLI-7LI.60 1435 +/- 600 Weight: 9 kg
Application:
■ Height, stagger and cant measuring
Technical description:
■ Laser measures
■ No need touching wires
■ Used in any weather conditions
■ Bluetooth Smart 4.0
■ Cant gauge
■ Easy transportation