The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
Edi lift truck impact monitoring
1. EDI SERIES IMPACT MONITORS
Impacts are a common occurrence
when you operate material handling
equipment. In most cases, impact
events are to be expected. However,
when these events get out of
control, they can cause extensive
damage which can adversely affect
safety and operating costs.
So how do you manage these
impact events so they have don’t
“impact” your bottom line ?
Managing
Lift Truck Impacts
2. EDI-1 IMPACT MONITOR
Stand alone unit with wireless cellular
reporting provided by Bolero plan.
EDI-2 IMPACT MONITOR
Stand alone unit with visual / audio warning
to the operator.
EDI-3 IMPACT MONITOR
Stand alone unit with visual / audio warning
to the operator, real-time, operator ID# and
downloading of data
PROPERTY DAMAGE
• Material Handling Equipment Damage
• Pallet Racking Damage
• Product Damage
• Docks and Dock Doors Damage
• Infrastructure Damage
HEALTH & SAFETY
• Ensure compliance with safety regulations and OSHA
requirements
• Reduce accidents
• Optional real time data for health & safety audits *
OPERATOR BEHAVIOR
• Ensures individual accountability
• Creates best practical procedures
• Provides operator (s) with clear path for corrective action
OPERATIONAL PRODUCTIVITY
• Reduce equipment downtime
• Optional productivity tools available **
• Optional real time data for productivity tracking *
* additional equipment or cellular plan may be required
** additional features sold separately
THE DEFENDER IMPACT MONITORS ALLOW YOU TO MANAGE AND CONTROL FOLLOWING
External Visual Warning
3. For more information, visit us @ www.skidweight.com
DEFENDER SERIES, IMPACT MONITOR SOLUTIONS AT A GLANCEDEFENDER SERIES, IMPACT MONITOR SOLUTIONS AT A GLANCE
SOLUTIONS FOR EVERY APPLICATION ... MODEL
* Stand alone basic model with cellular reporting.
* Bolero wireless cellular plan is required
* E-mail impact detection notification
* Operating voltage for 12 V DC electrical system
EDI-1
* Stand alone basic model with visual / audio impact detection warning
* Operating voltage from 12 to 55 V DC electrical system
EDI-2
* Stand alone model with operator ID#, recording of impact event, time/date
stamp of the impact detection
* USB data collection
* Operating voltage from 12 to 55 V DC
EDI-3
* Stand alone model with operator ID#, recording of impact event, time/date
stamp of the impact detection
* Onboard check weighing scale with overload warning
* USB data collection
* Operating voltage from 12 to 55 V DC
EDI-4
* Stand alone model with operator ID#, recording of impact event, time/date
stamp of the impact detection
* Onboard check weighing scale with overload warning
* Utilization warning
* Bar code scanner
* USB data collection
* Bluetooth
* Operating voltage from 12 to 55 V DC
EDI-5
* Stand alone model with operator ID#, recording of impact event, time/date
stamp of the impact detection
* Onboard check weighing scale with overload warning
* Onboard DIM dimensioning
* Bar code scanner
* Utilization warning
* USB data collectionBluetooth
* Operating voltage from 12 to 55 V DC
EDI-6
EDI-4 IMPACT MONITOR
Stand alone unit with visual / audio warning
to the operator, real-time reporting, operator
ID#, onboard check weighing, overload with
downloading of data.
EDI-5 SKIDFLEET IMPACT MONITOR 5.7”
TFT COLOR LCD SCREEN
Stand alone unit with visual / audio warning
to the operator, real-time reporting, operator
ID#, check weighing, overload, vehicle
utilization with downloading of data.
EDI-6 CUBEFREIGHT IMPACT MONITOR
5.7” COLOR LCD SCREEN
Stand alone unit with visual / audio warning
to the operator, real-time reporting, operator
ID#, check weighing, overload ,utilization, bar
code scanner, LTL dimensioning of freight
with downloading of data.
4. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse
molestaie cillum. Tia non ob ea soluad quae.
Standard function Optional function (availability depends on IM Defender version)
OPERATION AND FUNCTIONS EDI-1 EDI-2 EDI-3 EDI-4 EDI-5 EDI-6
Operational voltage (0-55 VDC) 12 V only
Impact detection visual warning (indicator) N/A
Impact detection audio warning (indicator)
Impact detection visual warning, external N/A
Impact detection audio warning, external N/A
Data transfer by USB stick N/A N/A
Data transfer by Bluetooth N/A N/A
Data transfer by cellular
Direct connection to computer’s USB port N/A N/A
USB interface N/A N/A
RJ 45 interface Ethernet connection N/A N/A N/A N/A
Data transfer by USB stick, authorized code input N/A N/A
Download status display N/A N/A N/A N/A
Check weighing onboard weighing scale N/A
Overload warning N/A N/A
Under utilization warning N/A N/A N/A N/A
Excessive engine idling warning N/A N/A N/A N/A
Real time clock N/A N/A
Operator ID# N/A N/A
Pre-shift safety check N/A N/A
Two independent weighing channels N/A
Bar code scanner N/A N/A N/A N/A
DIM , lift truck onboard dimensioning of freight weight N/A N/A N/A N/A N/A
Accumulative load weight function N/A
Printouts N/A
5. The information provided in this brochure contains only general descriptions or performance characteristics, which do not always apply
as described in case of actual use or which may change as a result of further development of the products. This information is merely a
technical description of the product. This information is not meant or intended to be a special guarantee for a particular application or
particular durability. An obligation to provide the respective characteristics shall only exist if expressly agreed in the term of the sales
contract. We reserve the right to make changes in availability as well as technical changes without prior notice.
Your Local Material Handling Dealer
Integrated Visual Data Technology Inc.
3439 Whilabout Terrace
Oakville, Ontario
Canada
L6L 0A7
Phone: +1 905-469-0985
Fax: +1 905-825-9494
www.skidweight.com
Managing Lift Truck Impacts, V1.1-2013
Pallet Height
Measurement
SkidLevel
Digital Tilt
Indicator
SkidLevel
Pallet Height
Sensor
System
ED5