FlexBar HRT Pressure Transmitter
4...20 mA, 2-wire transmitter,
HART® communication
Configurable span, unit and damping
Turn down 25:1
Zero point adjustment
2-point calibration
-1(0)...400 bar
Gauge or absolute pressure
400% overpressure safety limit
Hygienic process connections
Demko EEx ia IIC T5/T6, ATEX II 1G
Demko Ex N IIC T5/T6
Barbara Ex ia IIC T5/T6
Description
FlexBar HRT is a loop powered, configurable pressure transmitter. FlexBar HRT is used in food, chemical and petrochemical industries
FlexBar HRT measures the pressure by means of a polysilicon strain to measure absolute or gauge pressure for machine and hydraulic
gauge sensor. The electronics are separated from the media by a thin applications etc.
diaphragm and an oil-filling. Three different oil fillings are available
including a mineral oil complying with demands from FDA for use in The wide range of process connections together with the configurable
the food and pharmaceutical industries. facilities make FlexBar HRT the ideal choice for all pressure measuring
applications.
The electronics are located in a separate sealed housing giving
FlexBar HRT superb resistance to moisture. Cable connection is via Hygienic process connections for a wide range of standards are avail-
gland or plug. able for FlexBar HRT with a flush diaphragm and G1/2A male nipple.
Please refer to the data sheet for FlexBar HRT Accessories.
The HART® communication features on-line process calibration/
adjustment and transmitter configuration. The FlexView LC-display is optional.
Data Sheet A112-3400-1
Design and specifications subject to change without notice
2. Technical Data
Input Operational conditions
Measuring limits See "Ordering Details" Storage temperature -40...85°C
Overpressure 400% of f.r., max. 600 bar Process temperature Standard: -30...120°C
(continuously) Cleaning < 135°C for 15 min.
Cooling neck: -30...200°C
Output (Filling fluid DC550)
Signal span 4...20 mA or 20...4 mA {1} Ambient temperature -10...70°C
2-wire, HART® communication
Relative humidity < 98%, condensing
Output limits 3.5...23 mA {1}
Protection class Plug: IP 65
Characteristic Linear or customised with Gland: IP 65 + IP 66
max. 30 points {1}
Vibrations Lloyds Register, test 2
Accuracy < 0.2% f.r.
Shock test 100g for 10 msec.
Isolation voltage 500 Vac
(From housing to 4...20 mA connection) Operational condition effects
Resolution 12 bit Ambient temperature influence, measured at -10...70°C
Load equation RL < (VCC-6.5)/23 [kOhm] and max. span:
Zero point: < 0.05% per 10K
Display (optional)
Span: < 0.05% per 10K
Please refer to FlexView data sheet
Process temperature: < 0.2% per 10K
Opto-relay Cooling neck only: Media temperature (tm) influence in the
Voltage, standard Max. 230 Vac temperature interval 100...200°C:
Voltage, GL-approved Max. 60 Vac G1/2A: 20 mbar + (tm - 100) x 2.0 mbar
DC-voltage Max. 50 Vdc DS 722: 20 mbar + (tm - 100) x 0.5 mbar
Current, continuously Max. 50 mA ISO 2852: 20 mbar + (tm - 100) x 0.5 mbar
Current, pulse Max. 500 mA 3A/DN38: 20 mbar + (tm - 100) x 1.0 mbar
Relay function Set/reset {1} 3A/DN76: 20 mbar + (tm - 100) x 0.5 mbar
Varivent: 20 mbar + (tm - 100) x 0.5 mbar
Configuring limits
Span 4...100% of full range {1} Transitional behaviour
Zero point 0...96% of full range {1} Switch-on time 4 sec.
Auto zero -10...10% of full range {1} Sample time 0.5 sec.
Step response time < 1 sec.
Communication
Damping, t99 0...60 sec. (2 sec. steps) {1}
FlexProgrammer PC-program (Windows)
2-way communication Long-term drift Typ. 0.1% per year
(Refer to data sheet)
EMC data
HART® protocol HCF standard
Immunity EN 50082-2
Features {1} Read serial number
Emission EN 50081-2
Read/Change user ID
Read/Change configuration Approval (Demko) EEx ia IIC T5/T6, ATEX II 1G
Read input signal value Approval (Barbara) Ex ia IIC T5/T6
Read output signal value Supply range 6.5...30 Vdc
Input signal logging
Internal inductivity Li < 10 µH
2-point sensor trim
Current output trim Internal capacity Ci < 1 nF
Barrier data U < 30 Vdc ; I < 0.1 A ; P < 0.75 W
Power supply
Temperature class T1...T5: -10 < Tamb < 70°C
Nominal 24 Vdc T1...T6: -10 < Tamb < 50°C
Supply voltage 6.5...35 Vdc
Approval (Demko) Ex N IIC T5/T6
Effects caused by changes in power supply:
Temperature class T1...T5: -10 < Tamb < 70°C
Zero point 0.005% per V
T1...T6: -10 < Tamb < 50°C
Measuring range 0.001% per V
Error handling
Up/Down scaling 23 mA/3.5 mA {1}
Data Sheet A112-3400-1
Design and specifications subject to change without notice
3. Technical Data
Materials Electrical connection
Housing: Stainless steel (AISI 304/W1.4301) Cable entry Gland PG9, PG13.5 or M20
Pressure sensor: Polysilicon strain gauge Plug DIN 43650, form B
Plug DIN 43650, form A
Fill fluid: Ondina, Halocarbon or DC550
Wetted parts: Acid-proof stainless steel Approval
(AISI 316L/W1.4404) or Hastelloy C Germanischer Lloyd (with cable type no. 81 26-940)
Options: PTFE-teflon coating (Accofal 2G54)
Note
Other coatings on request
{1} Configurable
Disposal of product and packing
According to national laws or by returning to Bourdon-Haenni
Additional Description
The mounting of the pressure sensor ensures fast response time, Accessories for FlexBar HRT are usually supplied separately and must
excellent temperature compensation and high measuring accuracy. All be assembled by the customer. However, if you prefer the accessories
diaphragm weldings are checked with a helium leak-tester. to be assembled from the factory prior to delivery, please order type
number 81 26-950.
FlexBar HRT can be configured either with a handheld HART®
communicator or with the dedicated Bourdon-Haenni FlexProgrammer Having the HART® communication facilities the FlexBar HRT can be
unit connected to a standard PC. operated as a conventional 4...20 mA device, or it can be connected
to other HART® devices in a 2-wire HART® network, in one of three
Unless specified FlexBar HRT is supplied with a standard connection methods:
configuration:
Pressure at 4 mA: Minimum measuring limit Mixed-signal: Please refer to HART® literature
Pressure at 20 mA: Maximum measuring limit
Damping: 0 sec. Point-to-point: See „Applications“
Device address: 0
Multi-drop: See below
Multi-drop mode:
12 mA (for 3 slaves) + HART® communication signals
Master
4 mA 4 mA 4 mA
In Multi-drop mode up to 15 slaves can
be connected to a 2-wire cable. Each
device must have a unique device
number different from 0. In case that one
transmitter is given a device number of
0, the system will revert to Mixed-signal
mode.
Device 1 Device 2 Device 3
Measuring Units Conversion
bar PSI mH2O Pascal kPa MPa
5
1 14.5 10.197 10 100 0.1
Data Sheet A112-3400-1
Design and specifications subject to change without notice
4. Ordering Details - FlexBar HRT
816x xxxx xxxx
Type 4´ digit
4...20 mA 1
4...20 mA with opto-relay 2
4...20 mA with HART® communication 3
4...20 mA with HART® communication and opto-relay 4
Safety 5´ digit
Standard version 1
Demko EEx ia IIC T5/T6, ATEX II 1G 2
Demko Ex N IIC T5/T6 3
Barbara Ex ia IIC T5/T6 4
Cable connection 6´ digit
Gland PG13.5 1
Gland M20 2
Plug DIN 43650, form B {2} 3
Gland PG9 4
Plug DIN 43650, form A {2} {5} 5
Process connection position 7´ digit
At the base 1
At the rear 2
At the base with cooling neck 3
At the rear with cooling neck 4
Diaphragm surface 8´ digit
Standard 1
Covered with Teflon {3} 2
Oil filling 9´ digit
Ondina (Recommended for food industry applications, max. 120°C) 1
Halocarbon (For Oxygen measuring, max. 120°C) 2
DC550 (Silicone oil for high temperature applications, max. 200°C) 3
Process connection standard 10´ digit
Flush diaphragm, male nipple G1/2A PN400 AISI 316L 1
Flush diaphragm, male nipple G1/2A PN400 Hastelloy C-276 2
DS 722 Rotating female nut DN40 PN16 AISI 316L 3
ISO 2852 clamp DN38 PN40 AISI 316L 4
ISO 2852 clamp DN51 PN40 AISI 316L 5
3A hygienic connection DN38 PN40 AISI 316L 6
3A hygienic connection DN76 PN40 AISI 316L 7
GEA Tuchenhagen Varivent PN40 AISI 316L 8
SMS 1145 male nipple DN38 PN25 AISI 316L 9
M44 x 1.25 male nipple, pulp and paper version PN16 AISI 316L E
M44 x 1.25 male nipple, hygienic version PN16 AISI 316L F
ø43 mm hygienic connection PN16 AISI 316L G
DIN 11851 Rotating female nut DN40 PN25 AISI 316L H
DIN 11851 Rotating female nut DN50 PN25 AISI 316L J
SMS 1145 Rotating female nut DN38 PN25 AISI 316L K
SMS 1145 Rotating female nut DN51 PN25 AISI 316L L
1/2“-14 NPT male nipple, ANSI/ASME B1.20.1 PN400 AISI 316L N
Gauge connection for external seal {4} G1/2A PN16 DIN 16288 S
Pressure type 11´ digit
Relative pressure (bar) 1
Absolute pressure (bar) 2
Pressure range 12´ digit
-0.1...0.4 0...0.4 1
-0.4...1 0...1 2
-1.0...2.5 0...2.5 3
-1.0...6 0...6 4
-1.0...16 0...16 5
-1.0...40 0...40 6
-1.0...100 0...100 7
-1.0...400 0...400 8
Data Sheet A112-3400-1
Design and specifications subject to change without notice
5. Ordering Details - Notes
{2} Not available with relay
{3} P<16 bar. Also for use in food processing (FDA)
{4} P<16 bar. This connection has no diaphragm and no oil filling.
An external flange with seal and non-aggressive/non-conductive filling fluid must be mounted.
{5} Only available with process connection at the base
Non-Ex-application, Point-to-point
230 Vac
3 4
1 2
24 Vdc
4...20 mA
Resistance Power supply FlexBar HRT pressure transmitter
> 250 Ohms (or master) with FlexView display (optional)
Note
When the handheld HART® communicator is used for configuration of
the FlexBar HRT, the total series resistance in the 4...20 mA loop must
exceed 250 Ohms. The configurator must hold the device specific DDL
to be able to address all available HART® features.
Handheld HART®
communicator, model 275
Electrical Connection
Connector + 1 2 -
Screw terminals: DIN 43650 B
1 & 2: 4...20 mA loop
3 & 4: Opto-relay (optional)
Test terminals:
LED, lights during auto zero A multimeter (Ri < 2 Ohms) can
adjustment be connected to measure the loop
current without breaking the loop.
Auto Zero push button
Ground connector
1 & 2: Pins for connection
of FlexProgrammer
Data Sheet A112-3400-1
Design and specifications subject to change without notice
6. Dimensional Drawings
[mm] FlexView display is optional
Gland PG9, PG13.5
or M20
ø86
35 45
FlexBar HRT G1/2A, with gland Process connection at the base Process connection at the base
Process connection at the base with plug. Side view with display. Frontview
Side view
79.5 69.5
47.5 128.5
FlexBar HRT G1/2A, with plug Process connection at the rear Cooling neck (integrated). Specify
Process connection at the rear With display and plug mounting at the base or at the rear.
Side view Front view Add the indicated measure to height
Rotating male
26.4 nipple Teflon ring
Welding part
20.5
Leakhole
6.1
O-ring
40.5 ø64
M44 x 1.25 connection with M44 x 1.25 hygienic connection M44 x 1.25 pulp/paper version
cut through rotating male nipple mounted in welding part mounted in welding part
ø11.5 (4 holes)
77.3
39.4
15
ø43.7 ø65
84
ø43 mm connection with O-ring sealing ø43 mm connection with O-ring sealing mounted in
and DN25 rotating female nut (DIN 11851) welding part and with flange (shown without nut)
Data Sheet A112-3400-1
Design and specifications subject to change without notice
7. Dimensional Drawings
[mm] ø26
42.5 42.5
30 30
R6 R6
16 16
ø50.5 ø64
ø17.5
Gauge connection for Male nipple G1/2A ISO 2852 clamp ISO 2852 clamp
external seal {6} Flush diaphragm DN38 DN51
57 57
30
R6
32 32
ø54 ø25.3 ø72.3
ø50.5 ø91
DS 722 rotating female nut, DN40 3A hygienic, DN38 3A hygienic, DN76
30 48.5
31
12
24
ø68
ø84 DN 40 ø56
DN 50 ø86.5
GEA Tuchenhagen Varivent Male nipple 1/2-14 NPT DIN 11851 rotating female nut
30 30
DN 38 ø60
DN 51 ø70
DN 38 ø55
DN 51 ø65
SMS 1145 Rotating female nut SMS 1145 Male nipple
Notes
FlexBar HRT total measure:
Housing + (cooling neck) + connection
{6} This connection has no diaphragm and no oil filling. An external
flange with seal and non-aggressive/non-conductive filling fluid must
be mounted.
Data Sheet A112-3400-1
Design and specifications subject to change without notice
8. Ex-installation, Point-to-point
Zone 0/1 Safe area
230 Vac
5 8
1 2 3 4
4...20 mA 24 Vdc
FlexBar HRT FlexView display Barrier Power Supply
(Optional) (Ri > 250 Ohms)
FlexBar HRT is approved by Demko for EEx ia IIC T5/T6 and ATEX II FlexBar HRT is approved by Demko for Ex N IIC T5/T6 according to
GB/2002-11-01 This data sheet may only be reproduced in full.
1G according to the European standards EN 50014 and EN 50020 BS 6941:1988 for installation in zone 2 without a barrier.
FlexBar HRT is approved by Barbara for Ex ia IIC T5/T6.
FlexBar HRT must be installed in accordance with prevailing guidelines
for zone 0 or 1, and a certified, intrinsically safe zener barrier or
isolation barrier with the maximum values Umax= 30 Vdc; Imax= 0.1 A ;
Pmax= 0.75 W must be used.
Data Sheet A112-3400-1
Design and specifications subject to change without notice
9. FlexBar HRT for Homogenizer
Pressure transmitter 4...20mA
for homogenizer
High mechanical stability, LRS test 2
Pressure ranges 0...400 bar
Temperature range -30...120°C
Acid-proof stainless steel
FlexView LC-display
Description
FlexBar HRT with homogenizer connection is designed for this extreme The HART®communication features remote process control and
environment and application. There are four available connections. supervision as well as on-line calibration and adjustment of the
transmitter.
All wetted parts of the pressure transmitter are produced of acid-proof
stainless steel. The FlexBar HRT for homogenizer is delivered with a FlexView LC-
display.
The electronics are located in a separate sealed housing giving FlexBar
HRT superb resistance to moisture and a high mechanical stability. Cable
connections via gland or plug are available.
FlexBar HRT has a configurable damping to stabilize the output signal
and the read-out during the pulsating pressure coming from the
homogenizer.
Data Sheet A112-3400-2
Design and specifications subject to change without notice
10. Technical Data
Please refer to FlexBar HRT data sheet.
Ordering Details - FlexBar HRT for Homogenizer
816x 1x11 1x18
Type 4´ digit
4...20 mA 1
4...20 mA with opto-relay 2
4...20 mA with HART® communication 3
4...20 mA with HART® communication and opto-relay 4
Cable connection 6´ digit
Gland PG13.5 1
Gland M20 2
Plug DIN 43650, form B 3
Gland PG9 4
Plug DIN 43650, form A 5
Process connection 10´ digit
Flush diaphragm PN400 AISI 316L/W.1.4404 A
Flush diaphragm PN400 AISI 316L/W.1.4404 B
Flush diaphragm PN400 AISI 316L/W.1.4404 C
GB/2002-06-01 This data sheet may only be reproduced in full.
Flush diaphragm PN400 AISI 316L/W.1.4404 D
Dimensional Drawings
Version A Type number 816x 1x11 1A18 Version B Type number 816x 1x11 1B18
[mm]
80 80
Not included ø18
42.5
28
27.5
20 19.2
9.4 12.7
5.1 WxDxH
0 0
ø23.5 ø23.5 95 x 45 x 28
ø34.8 ø33.3
Type number 81 26-951 for version A Type number 81 26-952 for the versions B, C and D
5 pcs. backing ring, PTFE 5 pcs. O-ring, FPM70
5 pcs. O-ring, FPM70
Version C Type number 816x 1x11 1C18 Version D Type number 816x 1x11 1D18
50 50
38 38
20.1 20.1
14.9 14.9
0 0
ø23 ø23
ø35.8 ø34.5
G1 1/4
ø60
Data Sheet A112-3400-2
Design and specifications subject to change without notice
11. 3400-3
FlexBar HRT Accessories
Accessories for FlexBar HRT pressure
transmitter
Clamp rings
Welding parts
Blind plugs
Reductions
Flanges
Adaptors
O-rings
Wall bracket
Description
FlexBar HRT is a loop powered, configurable pressure Besides the fixed connections a range of replaceable,
transmitter with 4...20 mA output and HART® hygienic connections are available to mount on the
communication. FlexBar HRT model with a flush diaphragm and G1/2A
nipple.
FlexBar HRT is used to measure absolute or gauge
pressure. This data sheet holds data for accessories such as
welding parts, clamp rings etc. for FlexBar HRT.
A wide range of both national and international process
connections make FlexBar HRT the ideal choice for The FlexView display is optional - technical data can be
pressure measuring applications in the food, chemical found in the specific data sheet.
and petrochemical industries.
1
12. Accessories for FlexBar HRT
81 26-930 81 26-939
Flange, DN25, DIN 2527 for 816x xxxx x6xx Blind plug, 3A/DN76, hygienic
ø50.5
78
81 26-931
Flange, DN40, DIN 2527 for 816x xxxx x6xx
81 26-932 81 26-925
Flange, DN50, DIN 2527 for 816x xxxx x6xx Welding part, M44 x 1.25
81 26-933
Flange, DN80, DIN 2527 for 816x xxxx x6xx ø64
81 26-901
81 69-G901
Clamp ring, ISO 2852, DN38/PN64
Adaptor DIN 11851 for ø43 connection, DN40
(incl. union)
81 26-902
81 69-G902
Clamp ring, ISO 2852, DN51/PN10
Adaptor DIN 11851 for ø43 connection, DN50
81 26-903 (incl. union)
Clamp ring, ISO 2852, DN51/PN64
81 26-904
Clamp ring for flange, DIN 2527, DN38/PN64
(incl. spec. nut)
81 69-G903
Flange for ø43 connection mounting on 81 69-G911
4 holes ø11.5
15
81 26-905
Clamp ring for flange, DIN 2527, DN76/PN64 ø65
(incl. spec. nut) ø84
81 26-916 81 69-G911
Welding part, 3A/DN38, hygienic Welding part for ø43 mm connection
32
ø55 ø65
81 26-917 81 26-920
Welding part, 3A/DN76, hygienic Reduction DS 228-1/ ISO 16288
for 816x xxxx x1xx
32 Union G1/2 to nipple G1/2A
ø100
81 26-938
Blind plug, 3A/DN38, hygienic
81 26-921
Reduction DS 228-1/ ISO 16288
ø50.5 for 816x xxxx x1xx
Union G1/2 to nipple G3/8A
78 81 26-922
Reduction DS 228-1/ ISO 16288
for 816x xxxx x1xx
Union G1/2 to nipple G1/4A
[mm]
13. Accessories for FlexBar HRT
81 26-923 81 26-926
M4 damping screw for the reductions Teflon seal for M44 nipple, ø34.5 x ø40.5 x 0.8
(81 26-920, 81 26-921, 81 26-922)
82 23-903
81 26-971 FlexProgrammer configuration set comprises:
O-Rings (5 pcs.), NBR, DN38, FDA approved FlexProgrammer with 9 pole RS232C cable
3.5" Program diskettes
81 26-972 Battery plug
O-Rings (5 pcs.), EPDM, DN38, FDA approved Cable with test plugs
81 26-973
O-Rings (5 pcs.), Viton, DN38, FDA approved
81 26-976
O-Rings (5 pcs.), NBR, DN76, FDA approved
81 26-977
O-Rings (5 pcs.), EPDM, DN76, FDA approved
81 26-950
81 26-978 Factory assembly of accessories
O-Rings (5 pcs.), Viton, DN76, FDA approved
81 26-960
81 69-G981 Calibration certificate
O-Rings (5 pcs.), NBR70, M44/ø43, FDA approved
81 26-998
81 69-G982 Material certificate 3.1.b (EN 10204) - for wetted parts
O-Rings (5 pcs.), EPDM70, M44/ø43, FDA approved
81 69-G983
O-Rings (5 pcs.), FPM70, M44/ø43, FDA approved
81 26-962
Wall bracket for FlexBar HRT
80
64
97
[mm]
14. CombiConnect Hygienic Replaceable Connections
Description
CombiConnect is a series of hygienic, replaceable
connections in acid-proof stainless steel (W1.4404/AISI
316L). The concept fits the G1/2A nipple versions of
FlexBar HRT pressure transmitter and the CombiTemp
Pt100 sensor.
The products comply with the strict demands from the food
industry, represented by organisations such as 3A, FDA
and EHEDG.
It takes less than 2 minutes to mount the pressure
transmitter or Pt100 sensor on the CombiConnect
connection.
CombiConnect is an entirely new concept offering high
flexibility and a low stock. The connection system is the
ideal choice for customers measuring temperature and
pressure in environments with several different
connections.
Connection variants
DS 722: Dansk Standard
DIN 11851: Deutsches Institut für
Normung
SMS 1145: Sveriges Mekanförbunds
Standardcentral
BS 4825 (RJT): British Standard
ISO 2853 (IDF) and
ISO 2852 (Clamp): International Standardisation
Organisation
Varivent and Tri-Clover®: Company Standards
CombiConnect - Technical Data
Design O-rings
Acid-proof stainless steel, (W1.4404/AISI 316L). 0-ring Range Notes
Complies with the national standards DS 722, DIN 11851, Nitrile (NBR70) -30...100°C {1}, {2}
SMS 1145, BS 4825, ISO 2852 and ISO 2853. Etylene-propylene (EPDM70) -30...150°C {1}
Manufactured according to the relevant 3A Standards. Fluorocarbon (FPM70) -20...200°C
Complies with the demands in EN1672-2
Notes
Pressure range -1...25 bar
{1} Complies with the demands from FDA
Vibrations Lloyds Register, test 2
{2} Change recommended after 50 CIP cleanings at 130°C
Overpressure 400% of f.r., max. 600 bar
(continuously) Disposal of product and packing
According to national laws or by returning to Haenni.
Hygienic Installations
Measures to be taken at hygienic mounting according to "European Hygienic Equipment Design Group"
1. Avoid blind pockets when connecting two pipe ends.
2. The gasket between nipple and union must be levelled with the surface.
3. The union nipple and the gasket must be centered in respect to each other.
4. Avoid blind pockets where media and cleaning materials can be accumulated.
15. CombiConnect - Ordering Details
CombiConnect
8120 9xxx Type
1 Complete connection incl. O-ring, gasket and union ring {3}
2 Welding part
3 Union ring {3]
4 Gasket
Connection
01 Varivent, Tuchenhagen GEA, DN40/DN50
Connection
12 DS 722, DN40, Union
13 DS 722, DN40, Nipple
14 DS 722, DN50, Union
15 DS 722, DN50, Nipple
Connection
20 DIN 11851, DN25, Union
21 DIN 11851, DN25, Nipple
22 DIN 11851, DN40, Union
23 DIN 11851, DN40, Nipple
24 DIN 11851, DN50, Union
25 DIN 11851, DN50, Nipple
Connection
32 SMS 1145, DN38,Union
33 SMS 1145, DN38,Nipple
34 SMS 1145, DN51,Union
35 SMS 1145, DN51,Nipple
Connection
42 BS 4825, DN38, Union
43 BS 4825, DN38, Nipple
44 BS 4825, DN51, Union
45 BS 4825, DN51, Nipple
Connection
52 ISO 2853, DN38, Union
53 ISO 2853, DN38, Nipple
54 ISO 2853, DN51, Union
55 ISO 2853, DN51, Nipple
Connection
6B ISO 2852, DN38, Clamp
6C ISO 2852, DN51, Clamp
Connection
7U TriClover®, 3“, Clamp
{3} Not valid for nipple and clamp connections
CombiConnect Accessories
81 26-955 81 26-965
Mounting tool for O-ring O-ring for CombiConnect connections (5 pcs.)
DIN 11851, DN25 NBR, FDA approved
81 26-956 81 26-966
Mounting tool for O-ring O-ring for CombiConnect connections (5 pcs.)
DIN 11851, DN40/50 EPDM, FDA approved
BS 4825, DN38/51
81 26-967
81 26-957 O-ring for CombiConnect connections (5 pcs.)
Mounting tool for O-ring FPM (Viton), FDA approved
ISO 2853 and clamp, DN38/51
SMS 1145, DN38/51
17. CombiConnect - Mounting Instructions
+ =
CombiConnect connection
( +)
816x xx1x x1xx Mounting tool for CombiConnect FlexBar HRT with
Nipple G1/2A for CombiConnect CombiConnect
1 1) Mount the O-ring in CombiConnect.
2) The sensor tube must be screwed into the CombiConnect until
there is a 2 to 5 mm gap between the O-ring and the bottom.
3) Press CombiConnect against the mounting tool to prevent the
O-ring from sliding out. Tighten the sensor tube up at 20 Nm.
4) Tighten the safety-screw up at 2 Nm.
2 3 4
20 Nm
2 mm
50...100 N
2...5 mm 2 Nm
18. FlexBar HRT Accessories - Application Examples
FlexBar HRT with ø43 mm hygienic connection
FlexBar HRT on the bracket for wall mounting
Adaptor DIN 11851 for ø43 connection, DN40 (incl. union)
H-3400-3-GB/2000-07-21
FlexBar HRT with M44 hygienic connection
mounted with welding part
Adaptor DIN 11851 for ø43 connection, DN50 (incl. union)
Flange for ø43 connection mounting on a welding part
FlexBar HRT with DN38 clamp separator
Welding part, ø65 mm for ø43 mm connection
19. FlexBar 3501 Pressure Transmitter
4...20 mA, 2-wire transmitter,
HART® communication (Optional)
Stainless steel heavy duty housing
with LC-Display (Optional)
Configurable span, unit, damping and linearisation
Turn down 25:1
Accuracy better than 0.1%
Zero point adjustment
2-point calibration
Ranges 0...0.1 bar to -1(0)...70 bar
Gauge or absolute pressure
High overpressure safety limit
Demko EEx d [ia] IIC T4/T6, ATEX II 1G
Demko EEx ia IIC T4/T5, ATEX II 1G
Barbara Ex d [ia] IIC T4/T6
Description
FlexBar 3501 is a loop powered, configurable pressure transmitter On-site adjustment of span and zero point can be made in hazardous
measuring absolute or gauge pressure. zones with 4 push buttons on the transmitter.
The heavy duty housing in stainless steel, AISI 316, is specifically The HART® communication features on-line process calibration/
designed for applications in corrosive environments and medias. adjustment and transmitter configuration.
FlexBar 3501 measures the pressure by means of a ceramic, capaci- FlexBar 3501 is used in chemical and petrochemical industries as well
tive sensor. as in power plants and pulp and paper production.
The measuring sensor and the electronics are in a separate chamber If mounted with one of the hygienic connections, with flush mounted
eliminating the risk of pressure and media in the terminal chamber. ceramic measuring cell, the FlexBar 3501 is the ideal pressure trans-
mitter within harsh environmental measuring applications in the food-,
FlexBar 3501 is configurable either with a handheld HART® com- beverage and pharmaceutical industry.
municator or with the dedicated FlexProgrammer configuring tool
connected to a PC.
Data Sheet 3501-1
Design and specifications subject to change without notice
20. Technical Data
Input Error handling
Measuring limits 0...0.1 bar to -1(0)...70 bar Up/Down scaling {1} 23 mA/3.5 mA (NAMUR NE43)
Overpressure Specified for each range
Operational conditions
See "Ordering Details"
Storage temperature -40...85°C
Output Process temperature vs. type of O-ring
Nominal output 4...20 mA {1} O-ring, NBR -30...110°C
2-wire, HART® communication O-ring, EPDM -40...120°C
Linear output 3.5...21.5 mA O-ring, VITON -20...125°C
Output limits 3.5...23 mA {1} Ambient temperature Without display -40...85°C
With display -10...70°C
Characteristic Linear or customised with
max. 30 points {1} Relative humidity < 98%, cond. (IEC 68238)
Accuracy +/- 0.1% Protection class IP 66 + IP 67
Including combined effects of linearity, hysteresis and Vibrations Lloyds Reg. (IEC 60068-2-6)
repeatability (max. turn down 1:5) 5...25 Hz 4 mm ampl.
Hysteresis < 0.05% 25...100 Hz 4g
100...150 Hz 2g
Accuracy D/A converter < 0.05% of nominal output span
150...2000 Hz 1g
Isolation voltage > 500 Vac
Shock test 100g for 10 msec.
(From housing to 4...20 mA connection)
Long term test IEC 60770
Resolution 14 bit
Load equation RL < (VCC-12)/23 [kOhm] Operational condition effects
Ambient temperature influence, measured at -40...85°C
Display (optional)
and p > 1.0 bar:
Type 4 digits, 7 segment LCD, and a DOT
Zero point: < 0.1% per 10K
matrix area 7 x 20 pixels
Span: < 0.1% per 10K
Display range -9999...+9999
Digit height 11.5 mm Transitional behaviour
Switch-on time < 2 sec.
Configuring limits
Sample time < 0.25 sec.
URV limits 4...100% of full range {1}
Damping, t99 0...60 sec. (1 sec. steps) {1}
LRV limits 0...96% of full range {1}
Long-term drift Typ. 0.1% f.r. per year
Adjustment limits
EMC data
Span -10...10% of read-out
LSL < span < USL Immunity EN 50082-2, EN 61326
Zero point -10...10% of full range Emission EN 50081-1, EN 61326
Auto zero -10...10% of full range NAMUR NE21
Min. value > -1 bar rel.
Approval (Demko) EEx d [ia] IIC T4/T6, ATEX II 1G
LSL < auto zero < USL
Approval (Barbara) Ex d [ia] IIC T4/T6
Communication Temperature class T1...T4: -40 < Tamb < 85°C
FlexProgrammer PC-software (Windows) T1...T6: -40 < Tamb < 50°C
2-way communication Max. supply voltage Umax= 30 Vdc
®
HART protocol HCF standard Zones Media: 0; Housing: 1
Features {1} Read serial number
Approval (Demko) EEx ia IIC T4/T5, ATEX II 1G
Read/Change user ID
Read/Change configuration Temperature class T1...T4: -40 < Tamb < 85°C
Read input signal value T1...T5: -40 < Tamb < 70°C
Read output signal value Barrier data U < 30 Vdc ; I < 0.1 A; P < 0.75 W
Input signal logging Zones Media: 0; Housing: 0
2-point sensor trim
Internal inductivity 1.3 mH
Current output trim
Internal capacity 3 nF
Power supply
Nominal 24 Vdc
Supply voltage 12...35 Vdc
Effects caused by changes in power supply:
Zero point 0.005% per V (IEC 60770)
Measuring range 0.001% per V (IEC 60770)
Data Sheet 3501-1
Design and specifications subject to change without notice
21. Technical Data
Materials Test conditions
Housing Stainless steel (AISI 316/W1.4401) Configuration LRV = 0 bar ; URV = USL
Surface Cast, passivated Power supply 24 Vdc
Pressure sensor Ceramic capacitive sensor (Al2O3 - 96%) Amb. temperature 20°C +/- 2°C
Fill fluid None in standard versions. In diaphragm seals Amb. pressure 860...1060 hPa
according to customers specifications. Humidity 45...75% RH
Wetted parts Acid-proof stainless steel
(AISI 316L/W1.4404) Disposal of product and packing
According to national laws or by returning to Bourdon-Haenni
Electrical connection
Cable entry Gland M20, Polyamid, IP 68 Note
Gland M20, Brass, IP 66 {1} Configurable
Additional Description
Unless specified FlexBar 3501 is supplied with a standard The O-ring sealing between the process connection and the sensor is
configuration: available in 3 types matching different medias. Accessories for FlexBar
Pressure at 4 mA: Lower range limit (LSL) 3501 are usually supplied separately and must be assembled by the
Pressure at 20 mA: Upper range limit (USL) customer.
Damping: 0 sec.
Device address: 0 Having the HART® communication facilities the FlexBar 3501 can be
operated as a conventional 4...20 mA device, or it can be connected
FlexBar 3501 is available with 17 different integrated process to other HART® devices in a 2-wire HART® network, in one of three
connections and with seals according to the customers wishes. connection methods: Mixed-signal mode, Point-to-Point mode or Multi-
The housing is 270° rotatable in respect to the process connection. drop mode. Please refer to HART® literature.
The integrated 4-digit LC-display is optional.
Terms Overview
Output (mA)
23.0
Up scale limits
Transfer curve. Nominal curve for a -1...70 bar (rel)
21.5 Turn Down 1:5 (0...14 bar). pressure transmitter configured to a
Turn Down 1:1
20.0
Output limits
Nominal output
Linear output
LSL Lower Sensor Limit
USL Upper Sensor Limit
Down scale limits
LRV Lower Range Value
4.0 URV Upper Range Value
3.5
-1 0 7 14 70 105
pressure (bar)
LSL Full range USL
LRV Span URV Overpressure limit
Auto Zero
0% LRV limits 96%
4% URV limits 100%
Data Sheet 3501-1
Design and specifications subject to change without notice
22. Configuring
The functions of the push buttons
With display Symbol Without display Symbol
Menu <Menu> Zero + <Z+>
Up <Up> Zero - <Z->
Down <Down> Span + <S+>
Enter <Enter> Span - <S->
Functions for a transmitter with display:
ADJ Note CONF Note
Zero {2} LRV
Span {2} URV
Auto zero {2} Damp
Factory LRV-auto {2}
URV-auto {2}
FlexBar 3501 can be configured in three ways: Functions for a transmitter without display:
a) With the 4 push buttons. Function <Z+> <Z-> <S+> <S-> Note
b) With a PC, the dedicated FlexProgrammer configuring Zero Up Down {2, 3}
tool and the Flex-program software, version G1 or higher. Span Up Down {2, 3}
c) With the HART® handheld configurator, model 275 Auto zero Push Push {2, 4}
(versions 3501 2xxx xxxx only). LRV-auto Push Push {2, 4}
URV-auto Push Push {2, 4}
The LRV-auto and URV-auto functions
Notes
are used to adjust the transmitter in e.g. tank level measurements:
{2} Apply reference pressure
a) Empty the tank to zero level {3} Measure loop current with ampere meter
b) Set the LRV-auto function (output will be set to 4 mA) {4} Push simultaneously
c) Fill the tank to the max. level
d) Set the URV-auto function (output will be set to 20 mA) Configuring with FlexProgrammer
Select engineering unit from:
Configuring with the push buttons %, bar, mbar, PSI, mH2O, kPa, MPa, atm, inHG, mmHG.
Action Result
Push button > 0.5 sec. Turn down 25:1
and release Function/input valid 2-point sensor trim
30-point linearisation
No action in 10 secs. Display process data Logging
No value stored Out-of-range values
Scaling of output current
Push <M> Toggle functions TAG no. and notes
Info of cell type, materials, date, serial no.
Push <E> (in Function) Accept function
Adjustment with the push buttons
Push <E> (in Input) Value stored
Display process data Pressure in
Span (+10%)
Push <U> Increase value
Zero (+10%)
Push <D> Decrease value
Push and hold > 2 sec. Step with 0.01% of USL Factory adjustment
Push and hold > 7 sec. Step with 0.1% of USL
Push and hold > 12 sec. Step with 1% of USL Zero (-10%)
Push and hold > 17 sec. Step with 10% of USL
Span (-10%)
Pressure out
( I out and Display out )
Data Sheet 3501-1
Design and specifications subject to change without notice
23. Dimensional Drawings
Front view (with display) Rear View Bottom View
[mm] 153
30
50 Ground 140
35 connection
25
0 R 81
46.7
132
44
Note
Behind the front cover are no parts requiring user intervention. Do not remove the front cover, when the transmitter is energised.
Remove the rear cover to access the terminals for the 4...20 mA connection.
32 32 32
ø64
ø54 ø56
ISO2852 clamp, DN51 (front page photo) DS722, DN40 DIN11851, DN40
flush mounted ceramic cell flush mounted ceramic cell flush mounted ceramic cell
Measure DN25 DN40 DN50 DN80
A 53.8 53.8 51.8 47.8
A B 18 18 20 24
C ø115 ø150 ø160 ø200
D ø85 ø110 ø125 ø160
B
E ø14 ø18 ø18 ø18
E
D Holes 4 4 4 8
C
Flanged seal, DIN2527 form B, (see table)
flush mounted ceramic cell
31 20
12
32
ø68
ø72.3 ø84
ø91
3A/DN76 hygienic connection GEA Tuchenhagen, varivent DN40/50
flush mounted ceramic cell flush mounted ceramic cell
Data Sheet 3501-1
Design and specifications subject to change without notice
24. Ordering Details - FlexBar 3501
3501 xxxx xxxx
Type 5´ digit
4...20 mA 1
4...20 mA with HART® communication 2
Safety 6´ digit
Standard version 1
Demko EEx ia IIC T4/T5, ATEX II 1G 2
Demko EEx d [ia] IIC T4/T6, ATEX II 1G 4
Barbara Ex d [ia] IIC T4/T6 5
Cable connection 7´ digit
Female thread M20 - 2 pcs. Polyamid Gland M20, included 1
Display 8´ digit
Without display 1
Integrated, digital display 2
O-ring 9´ digit
Viton 1
EPDM (FDA approved) 2
NBR 3
Process connection standard 10´ digit
G1/2A gauge connection (DIN 16288) PN70 1
1/2“-14 NPT male nipple, ø3 mm hole PN70 2
G1/2A male nipple, ø10 mm hole PN70 3
1/2“-14 NPT male nipple, ø10 mm hole PN70 4
G1/2 female thread PN70 5
1/2“-14 NPT female thread PN70 6
1/2“-14 NPT male nipple, 1/4“-18 NPT, internal female thread {2} PN70 8
DS722 rotating female nut, flush mount {2} DN40 PN16 A
ISO2852 clamp, flush mount {2} DN51 PN40 B
3A hygienic connection, flush mount {2} DN76 PN40 C
GEA Tuchenhagen Varivent, flush mount {2} DN40/50 PN40 D
DIN11851 rotating female nut, flush mount {2} DN40 PN25 E
Flanged seal, DIN2527 form B, flush mount {2} DN25 PN40 F
Flanged seal, DIN2527 form B, flush mount {2} DN40 PN40 G
Flanged seal, DIN2527 form B, flush mount {2} DN50 PN40 H
Flanged seal, DIN2527 form B, flush mount {2} DN80 PN40 J
G1/2A gauge connection (DIN 16288) for external or remote seal (reduced volume), PN70 S
Pressure type 11´ digit
Relative pressure (bar) 1
Absolute pressure (bar) 2
Pressure range (over pressure limit) 12´ digit
-0.1...0.1 (-0.3...4) 1
0...0.1 (-0.3...6) 2
-0.1...0.4 (-1...6) 3
-0.4...1.0 (-1...10) 0...1 (-1...10) 4
-1...4 (-1...25) 0...4 (-1...25) 5
-1...10 (-1...40) 0...10 (-1...40) 6
-1...20 (-1...40) 0...20 (-1...40) 7
-1...40 (-1...60) 0...40 (-1...60) 8
-1...70 (-1...105) 0...70 (-1...105) 9
Notes
{2} Not available with EEx d approvals
Data Sheet 3501-1
Design and specifications subject to change without notice
25. Accessories
9000 0001 Bracket for mounting on wall or 2“ pipe
9000 0002 Adaptor M20 to PG13.5
9000 0003 Adaptor M20 to NPT 1/2“-14
9000 0004 Gland, Ex d, M20 x 1.5, Brass, IP 66
9000 0005 Blind plug, Ex d, M20 x 1.5, Brass
3501 9900 Configuration according to customers specifications
Non-Ex-Application Example, Point-to-point mode
Configuring 230 Vac
Handheld HART® communicator, model 275
4...20 mA 24 Vdc
Resistance Power supply FlexBar 3501
> 250 Ohms (or master) pressure transmitter
Note
When the HART® communicator is used for configuration of the FlexBar 3501, the total
series resistance in the 4...20 mA loop must exceed 250 Ohms. The configurator must hold
the device specific DDL to be able to address all available HART® features.
Non-Ex-Application Example, Multi-drop mode
12 mA (for 3 slaves) + HART® communication signals
Master
4 mA 4 mA 4 mA
Device 1 Device 2 Device 3
Note
In Multi-drop mode up to 15 slaves can be connected to a 2-wire cable.
The transmitters are „parked“ at a fixed output of 4 mA. Each device
must have a unique device number different from 0. In case that one
transmitter is given a device number of 0, the system will revert to
Mixed-signal mode.
Data Sheet 3501-1
Design and specifications subject to change without notice
26. Ex - Installation, Ex d
Hazardous area Safe area 230 Vac
5 8
250 Ohm
3 4
Zone 1
4...20 mA 24 Vdc
Zone 0
FlexBar 3501 Power Supply
(Ri > 250 Ohms for HART applications)
FlexBar 3501 is approved by Demko for EEx d [ia] IIC T4/T6, ATEX II Due to the heavy duty housing FlexBar 3501 is approved for EEx d
GB/2002-10-01 This data sheet may only be reproduced in full.
1G according to the European standards EN 50014, EN 50018 and and a barrier is not neccessary, provided that FlexBar 3501 is installed
EN 50020 and by Barbara for Ex d [ia] IIC T4/T6. in accordance with prevailing guidelines for zone 0 or 1.
The FlexBar 3501 can henceforth measure media classified as zone 0
medias. However the housing must be installed in zone 1 or 2.
Ex - Installation, Ex ia
Zone 0, 1 or 2 Safe area 230 Vac
5 8
250 Ohm
3 4
4...20 mA 24 Vdc
FlexBar 3501 Power Supply
(Ri > 250 Ohms for HART applications)
FlexBar 3501 is approved by Demko for EEx ia IIC T4/T5, ATEX II 1G FlexBar 3501 must be installed in accordance with prevailing
according to the European standards EN 50014 and EN 50020. guidelines for zone 0 or 1, and a certified, intrinsically safe zener
barrier or isolation barrier with the maximum values
Umax= 30 Vdc; Imax= 0.1 A ; Pmax= 0.75 W must be used.
Data Sheet 3501-1
Design and specifications subject to change without notice
27. FlexProgrammer
Easy to install
Operated from a standard PC
Can configure all Flex-products
User-friendly software with help menus
Description
The FlexProgrammer is the dedicated configuring tool for all Bourdon- The software is available in 6 languages having help menus, which
Haenni Flex-products (except FlexTop 2231 Profibus PA transmitter). makes it self-explanatory and easy to operate.
The FlexProgrammer unit is easy to connect to a standard PC with the The selected configuration can be stored under a file name determined
9-pole RS232C connector. by the user. A print facility is available for hard copy records.
Data Sheet A131-9901-1
Design and specifications subject to change without notice
28. Technical Data
Supply voltage Environmental conditions
Internal DTR signal from PC Operating temperature 0...50°C
Option External battery 9 V (PP3) Humidity < 90% RH, non-condensing
Data input RS232C Protection class IP 42
EMC data Disposal of product and packing
Immunity EN 50082-1 According to national laws or by returning to Bourdon-Haenni
Emission EN 50081-1
Installation
Hardware Software
The FlexProgrammer can be connected to an IBM-compatible PC with The Flex-program software must be installed on the hard disk by
the configuration listed below: running the Setup.exe file.
386 processor In the main menu the language and the COM-port can be selected.
3.5" floppy drive In the SETUP menu a choice between Celcius and Fahrenheit can
4 MB RAM be made.
Windows installed (3.11, 95, 98, NT, 2000, XP) In the EDIT menu the relevant parameters for each Flex-product can
A free serial RS 232C port (physical port) be configured.
2 MB free hard disk space At termination of the program the language and COM-port selections
will be stored on the hard disk.
Example of application - Configuring FlexTop 2201
GB/2002-06-01 This data sheet may only be reproduced in full.
Note:
Disconnect loop supply before
connecting the FlexProgrammer
to FlexTop 2201.
FlexProgrammer
Com LPT
9V
2 1 1 2
2 1
1 2
Power supply
If the PC is unable to supply the FlexProgrammer from the serial port
an external 9V (PP3) battery must be installed, using the battery plug
supplied.
The battery should be connected during configuration only. Otherwise
its lifetime will be reduced.
Ordering Details - FlexProgrammer
The FlexProgrammer set comprises: 82 23-903
FlexProgrammer with 1.5 m RS 232C cable with 9-pole plug
3.5 inch diskettes with the Flex-program software
Battery plug
Cable with test plugs
Adaptor for configuring of FlexTop 2201, FlexTop Iso and FlexTop HRT 9000 0007
Data Sheet A131-9901-1
Design and specifications subject to change without notice