How AI, OpenAI, and ChatGPT impact business and software.
Quality Center Overview: Connecting QTP to Schedule, Run Tests and Submit Defects
1.
2. Quality Center Overview
What is Quality Center
Quality Center Overview
Connecting Quick Test to Quality Center
Recording a script in QTP
Saving Tests to a Quality Center Project
Enabling Quality Center to Run Tests on a Quick Test Computer
Running a Test Stored in a Quality Center Project
Submitting Defects During a Run Session
Disconnecting Quick Test from Quality Center
Session Wrap-Up
pgorantla.blogspot.com
3. Quality Center Overview
Provide centralized Quality solution .
Provides an intuitive and efficient method for scheduling
and running tests, collecting results, analyzing the results,
and managing test versions .
It helps you to maintain a project of all kinds of tests.
A system for tracking and monitoring defects closely from
initial detection until resolution
pgorantla.blogspot.com
4. Quality Center Overview
Start QTP and from Tool
option select Quality Center.
In the server connection area in
server text box enter
http://<machine
name>/<tdbin>
and click on connect
In Project Connection area,
click on connect after selecting
Note:
project.
To work with quality center make sure you have TD (Test Director) and Test Director “Add-in for QTP” install on your
system. To install Add-in. Go to start->Test Director->Test Director 8.0->Add In page
•
•
Select Add in page option. And a web page would display select More Test Director Addins. A page would be
displayed and now select Quick Test Professional/Astra Quick Test Add-in option and Install add-in.
Now create a project in TD (Test Director) that would manage all tests scripts and create a folder in the test plan tab
that will contain scripts.
pgorantla.blogspot.com
5. Quality Center Overview
Click the Record button or choose Test > Record.
Browser("Welcome: Mercury Tours").Page("Welcome: Mercury Tours").WebEdit("userName").Set "ansh3"
Browser("Welcome: Mercury Tours").Page("Welcome: Mercury Tours").WebEdit("password").SetSecure
"42e60c5e3c6d48e1f992f755d59ce198"
Browser("Welcome: Mercury Tours").Page("Welcome: Mercury Tours").Image("Sign-In").Click 32,2
Browser("Welcome: Mercury Tours").Dialog("AutoComplete").WinButton("No").Click
Browser("Welcome: Mercury Tours").Page("Find a Flight: Mercury").WebList("passCount").Select "3"
Browser("Welcome: Mercury Tours").Page("Find a Flight: Mercury").Image("findFlights").Click 63,6
Browser("Welcome: Mercury Tours").Page("Find a Flight: Mercury").WebRadioGroup("outFlight").Select "Blue
Skies Airlines$191$723$7:08$"
Browser("Welcome: Mercury Tours").Page("Find a Flight: Mercury").Link("SIGN-OFF").Click
Browser("Welcome: Mercury Tours").Page("Sign-on: Mercury Tours").Sync
pgorantla.blogspot.com
6. Quality Center Overview
Connect to a Quality
Center server and
project. As explain
above.
In Quick Test, click
Save or choose File >
Save to save the test.
pgorantla.blogspot.com
7. Quality Center Overview
To enable remote Quality
Center clients to run tests on
Your Quick Test computer:
Open Quick Test.
Choose Tools > Options or
click the Options toolbar
button. The Options dialog
box opens.
Click the Run tab.
Select the “Allow other
Mercury products to run
tests and components”
check box.
pgorantla.blogspot.com
8. Quality Center Overview
Click on Test->Run
To save the run results,
you specify a name for the
run session and a test set in
which to store the results.
pgorantla.blogspot.com
9. Quality Center Overview
Defect Option
Run the test and
result window
would displayed
Select add defect
option given in the
tool bar just near
to quality center
icon a window get
open as shown
below
pgorantla.blogspot.com
11. Quality Center Overview
Tools > Quality Center
Connection or click the
Quality Center
Connection toolbar
button.
In project connection area
click on Disconnect.
In server connection area
click on Disconnect.
pgorantla.blogspot.com
13. Quality Center Overview
Quality Center provides an intuitive and efficient method
for scheduling and running tests, collecting results,
analyzing the results, and managing test versions.
It also helps you to submit and track defects. So enabling
you to monitor defects closely from initial detection until
resolution
Select the “Allow other Mercury products to run tests and
components” check box.
To work with quality center make sure you have TD (Test
Director) and Test Director “Add-in for QTP” install on your
system and a project in TD
pgorantla.blogspot.com
Notas do Editor
Briefly review the session agenda as indicated here.
Currently we are in the “Prep Session Introduction” section, during which we will review basic information about this session, including how to use Centra to participate.
Note: The Prep Session Introduction section should take no longer than 15 minutes.
Spend a few moments answering participants’ questions about the agenda of this session or the Centra controls they will be using. Remind them to use the “Raise Hand” icon to ask a question.