SlideShare uma empresa Scribd logo
1 de 34
Tecnologías de Reemplazo para HCFC de
  Bajo Potencial de Calentamiento Global y
 Eficientes Energéticamente en el Sector de
     Refrigeración y Aire Acondicionado


      Soluciones para
Aplicaciones Industriales con
    CO2 como Remplazo

     Leonilton Tomaz Cleto - Yawatz Engenharia
           Bogotá – Colombia – 22/04/2010
The peak of utilizing
       CO2 as refrigerant



                                 Reinvention of CO2-
                                 refrigeration technology
                                 (G. Lorentzen)




1850    1920 ----------1930    1960          1993
CO2 Thermodynamic Process

                 Transcritical Cycle




    Sub-critical Cycle
+35ºC
                                 R-744/R-717 – Cascade System

                               Compressor
                                                                       R717
                                 R-717




                                                       Pressure
         R717
R-744/R-717 – Cascade HX
        -12ºC                                                              +35oC (13.5 bar)
                -8ºC
                               Compressor                                  -12oC (2.7 bar)
                                 R-744

                                                                                                 Enthalpy
            -40ºC
       Liquid Sep.
                                                                        R-744




                                                       Pressure
                                                                                        -8oC (28.0 bar)
         R-744
                                                                                      -40oC (10 bar)




                       -40ºC
Evaporator – R-744                                                                               Enthalpy

                                            By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
+35ºC                R-744/R-717 – Cascade System
                                R-744 Hot Gas Defrost

                               Compressor
                                                                       R717
                                 R-717




                                                       Pressure
         R717

R-744/R-717 – Cascade HX
        -12ºC                                                              +35oC (13.5 bar)

                -8ºC
                               Compressor                                  -12oC (2.7 bar)
                                 R-744

                                                                                                 Enthalpy
            -40ºC
       Liquid Sep.
                                                                        R-744
                                                                                                +8 oC     (43 bar)




                                                       Pressure
                                    Compressor                                             -8oC (28.0 bar)
         R-744                       for Defrost
                                                                                      -40oC (10 bar)




                       -40ºC
Evaporator – R-744                                                                               Enthalpy

                                            By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
+35ºC
                                                            R-744/R-717 Cascade System
                                                          Pumped CO2 as Secundary Fluid
                                             Compressor
                  R717                         R-717

         R-717/R-744 – Trocador “Cascata”

                -14ºC
                                                                  R717
                        -10ºC
                                            Compressor
                                              R-744
                                                                   +35ºC (13.5 bar)

  -10ºC           Sep. Líquido                                     -14ºC (2.5 bar)
Sep. Líquido

                    CO2                                                    Enthalpy




        Evaporador – R-744      -10ºC

                    -40ºC                                          R-744
               Sep. Líquido
                                                                           -10ºC (26.4 bar)

                     CO2                                                   -40ºC (10 bar)




                                                                              Enthalpy
                                 -40ºC
        Evaporador – R-744
R-744 x R-717 – Compressor Displacement

                 R-744                                       R-22

           HPC104S


Compressors:                   Vs x 7-10


                     HPC106S

                                                                            3 x SAB202SF




                                      By John Ritmann – York Refrigeration - 2004
R-744 x R-717 – Compressor Displacement




   R-22
                                                R-744




                         By John Ritmann – York Refrigeration - 2004
R-744/R-717 – Cascade System

      No se puede mostrar la imagen. Puede que su equipo no tenga suficiente memoria para abrir la imagen o que ésta esté dañada. Reinicie el equipo y , a continuación, abra el archiv o de nuev o. Si sigue apareciendo la x roja, puede que tenga que borrar la imagen e insertarla de nuev o.




                                                                                                                                                                                                                                                                                                    By John Ritmann – York Refrigeration - 2004
R-744/R-717 – Cascade System




                         By John Ritmann – York Refrigeration - 2004
R-717 – PHE Chillers
R-744 Compressors
                Transcritical Cycle




Transcritical CO2 for Industrial Refrigeration - By Yoshikawa – Mayekawa Co.
               Danfoss IR Consensus - 30/11/2004
R-744 Compressors
                Transcritical Cycle




Transcritical CO2 for Industrial Refrigeration - By Yoshikawa – Mayekawa Co.
               Danfoss IR Consensus - 30/11/2004
Design Pressure




                  By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
Optimized COP




                By L. Tomaz Cleto – Yawatz Engenharia - 2007
COP Comparison of Refrigeration Systems
COP – R-744/R-717 Cascata x R-717 “Booster”




                           By L. Tomaz Cleto – Yawatz Engenharia - 2007
Data for comparison of
                           pipe cross section areas

Common calculation data:
Capacity                                               250 kW
Temperature Drop in Dry Suction                           0.8 K
Line: ∆T
Temperature Drop in Wet return                            0.8 K
Line: ∆T
Circulating Rate (Liquid Pump)                                 3
Velocity in Liquid Line                                 0.8 m/s
Equivalent Pipe Length                                    50 m
Evaporating Temperature                                  -40 oC
Condensing Temperature                                   -15 oC
                               By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
Comparison of pipe cross
section area
Dry suction / Liquid lines




   By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
Comparison of pipe cross
section area
Wet return / Pumped Liquid lines




   By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
Comparison of pipe cross
                       section area
                       Dry suction / Liquid lines
Index


                 5%
                 95%
                                                                          Liquid
                                                                          Suction




                                     4%
                                    96%
CO2=                                                                            30%
                                                                                70%


        R-134a         R-717                                  R-744
                         By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
Comparison of
                                 pressure and subcooling
                                 produced in liquid risers

      Refrigerante              R-134a                     R-717                        R-744
Pressure produced in
liquid riser    ”∆p”     bar     0.418                     0.213                        0.329

Subcooling produced in
liquid riser  ”∆ t ”     K       14.91                       5.21                        0.88




                         CO2 reciever
                                             H=3m                   ∆p ∆t




                                   By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
Safety Valves
                        CO2 expansion - phase changes                                                  +31 oC
                                                                                                        31.0ºC

                                                                    Supercritical
                                                                                                           Vapor - 50 bar


                                                       Liquid                                               Vapor - 35 bar


                                   Liquid - 20 bar
Pressure (bar abs)




                              Sólido -Liquido
                                                                 Liquido - Vapor
                               50% solid CO2 at                                                             0% solid CO2 at       the
                     Sólido    the triple point                                                             triple point
                                                                            -56.6 oC
                                                                             5.2 bar
                                                                                                            3% solid CO2 at       the
                                      Solid - Vapor                                                         triple point


                                                                                                         Vapor
                                         -78.4    oC




                                                        Enthalpy

                                                                By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
Safety Valves
CO2 Expansion – Trapped Liquid

                Relative liquid volume
Volume Change




                        Temperature
                                By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
R-744/R-717 – Cascade System

      No se puede mostrar la imagen. Puede que su equipo no tenga suficiente memoria para abrir la imagen o que ésta esté dañada. Reinicie el equipo y , a continuación, abra el archiv o de nuev o. Si sigue apareciendo la x roja, puede que tenga que borrar la imagen e insertarla de nuev o.




                                                                                                                                                                                                                                                                                                    By John Ritmann – York Refrigeration - 2004
Water Solubility


                       Water Solubility – Vapour Phase
Water Content (ppm)/




                                                                     CO2 +
 kg of Refrigerant




                       CO2 +                                         Water
                        Ice



                                                        CO2 +
                                                      Water Vapour


                               Temperature
                                     By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
R-744 (CO2) as REFRIGERANT
Primary Refrigerant – (Sub-Critical Cycle):
   Low Temperatures – Cascade System (-30ºC to -55ºC)
   Higher COP for temperature lower than -35ºC
   Lower Compressor Displacement
   Small refrigerant lines
   Low Toxicity ( ASHRAE Standard 34 - Class - A1 – TLV = 5000 ppm > HFCs)
   No flammable


   High Pressure(40 - 60 bar)
   New Technologies (Some conceptions from “Freon” Systems)
   Higher Water Solubility
R-744 (CO2) as REFRIGERANT


Secondary Refrigerant:
  IntermediateTemperatures (-20.0ºC to 0.0ºC)
  Two-phase Flow
  High Heat Transfer Coefficient
  Very Small Refrigerant Lines
Industrial Refrigeration Market
Industrial Refrigeration – EU
   JCI-York – DK (Sabroe/ Frick)
   GEA-Grasso
   Danfoss
   Alfa-Laval
   Star Refrigeration
   FMC - Frigoscandia
   Mayekawa (Japan)
   IIR-IIF
   USA to support CO2 solutions
Market Trend
   Industrial Refrigeration in Brasil

Food Industry
  R-717, Ammonia and NH3
  PHE Chillers – Reduced Refrigerant Charge
  Secondary Fluids (-15.0ºC a 0.0ºC)
  R-744 - ??? – Great Future!
  Legislation/ Safety   NBR 16069:2010
Market Trend
      Industrial Refrigeration in Brasil

Process Industry/ Industrial Air Conditioning
   R-22 – Almost “Naturally” Phased Out
   R-717 Plants
   HCs – (R-1270) – Classified Area
   R717 – PHE Chillers – Reduced Refrigerant Charge
   HFCs – Chilled Water Systems
Natural Refrigerants in Brasil (2010)

More than 80% of the food industry using R-717 plants.
Hundreds of R717 PHE Chillers:
   Mainly for Process and Food Industry.
   Very few in air conditioning for office buildings.
   4 Supermarkets using PHE chillers and secondary fluids (LT/ MT/ AC).

Few plants using HCs (Chemical Industry).
1 R-744/R-717 cascade system for food industry.
1 R-744/R-404A cascade system for supermarket.
2-3 new projects using R-744 cascade system for distribution
centers.

Mais conteúdo relacionado

Mais procurados

Combustion & Flue Gas Analysis
Combustion & Flue Gas AnalysisCombustion & Flue Gas Analysis
Combustion & Flue Gas Analysis
Amit Makwana
 
Saudi Aramco Carbon Management - May 2013
Saudi Aramco Carbon Management - May 2013Saudi Aramco Carbon Management - May 2013
Saudi Aramco Carbon Management - May 2013
Global CCS Institute
 

Mais procurados (20)

Ammonia CO2 Removal Systems
Ammonia CO2 Removal SystemsAmmonia CO2 Removal Systems
Ammonia CO2 Removal Systems
 
Combustion & Flue Gas Analysis
Combustion & Flue Gas AnalysisCombustion & Flue Gas Analysis
Combustion & Flue Gas Analysis
 
Carbon Capture & Storage
Carbon Capture & StorageCarbon Capture & Storage
Carbon Capture & Storage
 
Steam Reforming - (ATM) Approach to Equilibrium
Steam Reforming - (ATM) Approach to EquilibriumSteam Reforming - (ATM) Approach to Equilibrium
Steam Reforming - (ATM) Approach to Equilibrium
 
6. phase separatation
6. phase separatation6. phase separatation
6. phase separatation
 
Steam Reforming - Poisons
Steam Reforming - PoisonsSteam Reforming - Poisons
Steam Reforming - Poisons
 
Capture of CO2
Capture of CO2Capture of CO2
Capture of CO2
 
Module 8 (fuels and combustion)
Module 8 (fuels and combustion)Module 8 (fuels and combustion)
Module 8 (fuels and combustion)
 
GAS PROCESSING PRESENTATION.pdf
GAS PROCESSING PRESENTATION.pdfGAS PROCESSING PRESENTATION.pdf
GAS PROCESSING PRESENTATION.pdf
 
Excess air
Excess airExcess air
Excess air
 
Catalysis12
Catalysis12Catalysis12
Catalysis12
 
Ammonia converter
Ammonia converterAmmonia converter
Ammonia converter
 
Hydrocarbon Feed Purification for Ammonia Plants
Hydrocarbon Feed Purification for Ammonia PlantsHydrocarbon Feed Purification for Ammonia Plants
Hydrocarbon Feed Purification for Ammonia Plants
 
Saudi Aramco Carbon Management - May 2013
Saudi Aramco Carbon Management - May 2013Saudi Aramco Carbon Management - May 2013
Saudi Aramco Carbon Management - May 2013
 
Amines
AminesAmines
Amines
 
Will it leak?: Discussions of leakage risk from subsurface storage of carbon ...
Will it leak?: Discussions of leakage risk from subsurface storage of carbon ...Will it leak?: Discussions of leakage risk from subsurface storage of carbon ...
Will it leak?: Discussions of leakage risk from subsurface storage of carbon ...
 
tail gas H2S/SO2 analyzer
tail gas H2S/SO2 analyzer tail gas H2S/SO2 analyzer
tail gas H2S/SO2 analyzer
 
Oils and their relationship to refrigeration systems -RETA conference 2015
Oils and their relationship to refrigeration systems -RETA conference 2015Oils and their relationship to refrigeration systems -RETA conference 2015
Oils and their relationship to refrigeration systems -RETA conference 2015
 
CO2 capture from NGCC Flue Gas and Ambient Air Using PEI-Silica Adsorbent - D...
CO2 capture from NGCC Flue Gas and Ambient Air Using PEI-Silica Adsorbent - D...CO2 capture from NGCC Flue Gas and Ambient Air Using PEI-Silica Adsorbent - D...
CO2 capture from NGCC Flue Gas and Ambient Air Using PEI-Silica Adsorbent - D...
 
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and PetrochemicalsFired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
 

Destaque

Carbon dioxide solutions
Carbon dioxide solutionsCarbon dioxide solutions
Carbon dioxide solutions
UNEP OzonAction
 
New ton presentation_c
New ton  presentation_cNew ton  presentation_c
New ton presentation_c
EUROPAGES
 
04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...
04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...
04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...
Koeppen Halvart
 
Cascade Refrigeration System 2016
Cascade Refrigeration System 2016Cascade Refrigeration System 2016
Cascade Refrigeration System 2016
Srikanta Biswas
 

Destaque (11)

3 Things You Should Know About the Changing Refrigeration Climate
3 Things You Should Know About the Changing Refrigeration Climate3 Things You Should Know About the Changing Refrigeration Climate
3 Things You Should Know About the Changing Refrigeration Climate
 
Carbon dioxide solutions
Carbon dioxide solutionsCarbon dioxide solutions
Carbon dioxide solutions
 
K10854 Experimental evaluation of cascade refrigeration plant
K10854 Experimental evaluation of cascade refrigeration plantK10854 Experimental evaluation of cascade refrigeration plant
K10854 Experimental evaluation of cascade refrigeration plant
 
Porous materials and metallic foams
Porous materials and metallic foamsPorous materials and metallic foams
Porous materials and metallic foams
 
New ton presentation_c
New ton  presentation_cNew ton  presentation_c
New ton presentation_c
 
John scherer-3-atmo america2016-ammonia refrigeration-nh3fa2016
John scherer-3-atmo america2016-ammonia refrigeration-nh3fa2016John scherer-3-atmo america2016-ammonia refrigeration-nh3fa2016
John scherer-3-atmo america2016-ammonia refrigeration-nh3fa2016
 
04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...
04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...
04 Shecco Low Gwp Alternatives In Commercial Refrigeration Christianna Papaza...
 
Carbon dioxide Industries
Carbon dioxide IndustriesCarbon dioxide Industries
Carbon dioxide Industries
 
Carbon dioxide
Carbon dioxideCarbon dioxide
Carbon dioxide
 
Different Techniques for Carbon Dioxide Capture from Air
Different Techniques for Carbon Dioxide Capture from AirDifferent Techniques for Carbon Dioxide Capture from Air
Different Techniques for Carbon Dioxide Capture from Air
 
Cascade Refrigeration System 2016
Cascade Refrigeration System 2016Cascade Refrigeration System 2016
Cascade Refrigeration System 2016
 

Mais de UNEP OzonAction

What can we do in Hungary for safer environment in utilization of SF6
What can we do in Hungary for safer environment in utilization of SF6What can we do in Hungary for safer environment in utilization of SF6
What can we do in Hungary for safer environment in utilization of SF6
UNEP OzonAction
 
Proper management and responsible use of refrigerants
Proper management and responsible use of refrigerantsProper management and responsible use of refrigerants
Proper management and responsible use of refrigerants
UNEP OzonAction
 
The influence on leakage rate of RAC equipment
The influence on leakage rate of RAC equipmentThe influence on leakage rate of RAC equipment
The influence on leakage rate of RAC equipment
UNEP OzonAction
 
Energy Performance of Building Directive, energetic inspection, equipment and...
Energy Performance of Building Directive, energetic inspection, equipment and...Energy Performance of Building Directive, energetic inspection, equipment and...
Energy Performance of Building Directive, energetic inspection, equipment and...
UNEP OzonAction
 
Registration of Operators and administration of refrigeration circuits, IT ba...
Registration of Operators and administration of refrigeration circuits, IT ba...Registration of Operators and administration of refrigeration circuits, IT ba...
Registration of Operators and administration of refrigeration circuits, IT ba...
UNEP OzonAction
 
Scope and tools of theoretical traning and assassement
Scope and tools of theoretical traning and assassementScope and tools of theoretical traning and assassement
Scope and tools of theoretical traning and assassement
UNEP OzonAction
 
Hungarian Refrigeration and Air Conditioning Associtation
Hungarian Refrigeration and Air Conditioning AssocitationHungarian Refrigeration and Air Conditioning Associtation
Hungarian Refrigeration and Air Conditioning Associtation
UNEP OzonAction
 
Personnel and Company Certification Hungary
Personnel and Company Certification HungaryPersonnel and Company Certification Hungary
Personnel and Company Certification Hungary
UNEP OzonAction
 
"Closed-technology" Certification and Monitoring tools for RAC and HP sector
"Closed-technology" Certification and Monitoring tools for RAC and HP sector"Closed-technology" Certification and Monitoring tools for RAC and HP sector
"Closed-technology" Certification and Monitoring tools for RAC and HP sector
UNEP OzonAction
 
Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?
Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?
Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?
UNEP OzonAction
 
The "merged" Hungarian govermental regulation
The "merged" Hungarian govermental regulationThe "merged" Hungarian govermental regulation
The "merged" Hungarian govermental regulation
UNEP OzonAction
 
National Conferedration of Refrigeration Guids
National Conferedration of Refrigeration GuidsNational Conferedration of Refrigeration Guids
National Conferedration of Refrigeration Guids
UNEP OzonAction
 
The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...
The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...
The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...
UNEP OzonAction
 
F-Gaz Regulation - Implementation in France
F-Gaz Regulation - Implementation in FranceF-Gaz Regulation - Implementation in France
F-Gaz Regulation - Implementation in France
UNEP OzonAction
 
Thematic meeting on HPMPs, certification and log-books
Thematic meeting on HPMPs, certification and log-booksThematic meeting on HPMPs, certification and log-books
Thematic meeting on HPMPs, certification and log-books
UNEP OzonAction
 
OzonAction Special Issue 2011
OzonAction Special Issue 2011OzonAction Special Issue 2011
OzonAction Special Issue 2011
UNEP OzonAction
 
ODS smuggling criminal enforcement
ODS smuggling criminal enforcementODS smuggling criminal enforcement
ODS smuggling criminal enforcement
UNEP OzonAction
 
Legislative response to ODS illegal trade
Legislative response to ODS illegal tradeLegislative response to ODS illegal trade
Legislative response to ODS illegal trade
UNEP OzonAction
 
Unep’s initiatives enforcement
Unep’s initiatives enforcementUnep’s initiatives enforcement
Unep’s initiatives enforcement
UNEP OzonAction
 

Mais de UNEP OzonAction (20)

What can we do in Hungary for safer environment in utilization of SF6
What can we do in Hungary for safer environment in utilization of SF6What can we do in Hungary for safer environment in utilization of SF6
What can we do in Hungary for safer environment in utilization of SF6
 
Proper management and responsible use of refrigerants
Proper management and responsible use of refrigerantsProper management and responsible use of refrigerants
Proper management and responsible use of refrigerants
 
The influence on leakage rate of RAC equipment
The influence on leakage rate of RAC equipmentThe influence on leakage rate of RAC equipment
The influence on leakage rate of RAC equipment
 
Energy Performance of Building Directive, energetic inspection, equipment and...
Energy Performance of Building Directive, energetic inspection, equipment and...Energy Performance of Building Directive, energetic inspection, equipment and...
Energy Performance of Building Directive, energetic inspection, equipment and...
 
Registration of Operators and administration of refrigeration circuits, IT ba...
Registration of Operators and administration of refrigeration circuits, IT ba...Registration of Operators and administration of refrigeration circuits, IT ba...
Registration of Operators and administration of refrigeration circuits, IT ba...
 
Scope and tools of theoretical traning and assassement
Scope and tools of theoretical traning and assassementScope and tools of theoretical traning and assassement
Scope and tools of theoretical traning and assassement
 
Hungarian Refrigeration and Air Conditioning Associtation
Hungarian Refrigeration and Air Conditioning AssocitationHungarian Refrigeration and Air Conditioning Associtation
Hungarian Refrigeration and Air Conditioning Associtation
 
Personnel and Company Certification Hungary
Personnel and Company Certification HungaryPersonnel and Company Certification Hungary
Personnel and Company Certification Hungary
 
"Closed-technology" Certification and Monitoring tools for RAC and HP sector
"Closed-technology" Certification and Monitoring tools for RAC and HP sector"Closed-technology" Certification and Monitoring tools for RAC and HP sector
"Closed-technology" Certification and Monitoring tools for RAC and HP sector
 
Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?
Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?
Refrigeration Policy in Hungary - HCFC phase out? HFC phase down?
 
The "merged" Hungarian govermental regulation
The "merged" Hungarian govermental regulationThe "merged" Hungarian govermental regulation
The "merged" Hungarian govermental regulation
 
National Conferedration of Refrigeration Guids
National Conferedration of Refrigeration GuidsNational Conferedration of Refrigeration Guids
National Conferedration of Refrigeration Guids
 
The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...
The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...
The Duch approch - Netherlands experience from 1991 till F-gas regulation in ...
 
F-Gaz Regulation - Implementation in France
F-Gaz Regulation - Implementation in FranceF-Gaz Regulation - Implementation in France
F-Gaz Regulation - Implementation in France
 
The EU F-Gas Regulation
The EU F-Gas RegulationThe EU F-Gas Regulation
The EU F-Gas Regulation
 
Thematic meeting on HPMPs, certification and log-books
Thematic meeting on HPMPs, certification and log-booksThematic meeting on HPMPs, certification and log-books
Thematic meeting on HPMPs, certification and log-books
 
OzonAction Special Issue 2011
OzonAction Special Issue 2011OzonAction Special Issue 2011
OzonAction Special Issue 2011
 
ODS smuggling criminal enforcement
ODS smuggling criminal enforcementODS smuggling criminal enforcement
ODS smuggling criminal enforcement
 
Legislative response to ODS illegal trade
Legislative response to ODS illegal tradeLegislative response to ODS illegal trade
Legislative response to ODS illegal trade
 
Unep’s initiatives enforcement
Unep’s initiatives enforcementUnep’s initiatives enforcement
Unep’s initiatives enforcement
 

Último

CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
giselly40
 

Último (20)

Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 

CO2 industrial applications

  • 1. Tecnologías de Reemplazo para HCFC de Bajo Potencial de Calentamiento Global y Eficientes Energéticamente en el Sector de Refrigeración y Aire Acondicionado Soluciones para Aplicaciones Industriales con CO2 como Remplazo Leonilton Tomaz Cleto - Yawatz Engenharia Bogotá – Colombia – 22/04/2010
  • 2. The peak of utilizing CO2 as refrigerant Reinvention of CO2- refrigeration technology (G. Lorentzen) 1850 1920 ----------1930 1960 1993
  • 3.
  • 4. CO2 Thermodynamic Process Transcritical Cycle Sub-critical Cycle
  • 5. +35ºC R-744/R-717 – Cascade System Compressor R717 R-717 Pressure R717 R-744/R-717 – Cascade HX -12ºC +35oC (13.5 bar) -8ºC Compressor -12oC (2.7 bar) R-744 Enthalpy -40ºC Liquid Sep. R-744 Pressure -8oC (28.0 bar) R-744 -40oC (10 bar) -40ºC Evaporator – R-744 Enthalpy By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 6. +35ºC R-744/R-717 – Cascade System R-744 Hot Gas Defrost Compressor R717 R-717 Pressure R717 R-744/R-717 – Cascade HX -12ºC +35oC (13.5 bar) -8ºC Compressor -12oC (2.7 bar) R-744 Enthalpy -40ºC Liquid Sep. R-744 +8 oC (43 bar) Pressure Compressor -8oC (28.0 bar) R-744 for Defrost -40oC (10 bar) -40ºC Evaporator – R-744 Enthalpy By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 7. +35ºC R-744/R-717 Cascade System Pumped CO2 as Secundary Fluid Compressor R717 R-717 R-717/R-744 – Trocador “Cascata” -14ºC R717 -10ºC Compressor R-744 +35ºC (13.5 bar) -10ºC Sep. Líquido -14ºC (2.5 bar) Sep. Líquido CO2 Enthalpy Evaporador – R-744 -10ºC -40ºC R-744 Sep. Líquido -10ºC (26.4 bar) CO2 -40ºC (10 bar) Enthalpy -40ºC Evaporador – R-744
  • 8. R-744 x R-717 – Compressor Displacement R-744 R-22 HPC104S Compressors: Vs x 7-10 HPC106S 3 x SAB202SF By John Ritmann – York Refrigeration - 2004
  • 9. R-744 x R-717 – Compressor Displacement R-22 R-744 By John Ritmann – York Refrigeration - 2004
  • 10. R-744/R-717 – Cascade System No se puede mostrar la imagen. Puede que su equipo no tenga suficiente memoria para abrir la imagen o que ésta esté dañada. Reinicie el equipo y , a continuación, abra el archiv o de nuev o. Si sigue apareciendo la x roja, puede que tenga que borrar la imagen e insertarla de nuev o. By John Ritmann – York Refrigeration - 2004
  • 11. R-744/R-717 – Cascade System By John Ritmann – York Refrigeration - 2004
  • 12. R-717 – PHE Chillers
  • 13. R-744 Compressors Transcritical Cycle Transcritical CO2 for Industrial Refrigeration - By Yoshikawa – Mayekawa Co. Danfoss IR Consensus - 30/11/2004
  • 14. R-744 Compressors Transcritical Cycle Transcritical CO2 for Industrial Refrigeration - By Yoshikawa – Mayekawa Co. Danfoss IR Consensus - 30/11/2004
  • 15. Design Pressure By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 16. Optimized COP By L. Tomaz Cleto – Yawatz Engenharia - 2007
  • 17. COP Comparison of Refrigeration Systems
  • 18. COP – R-744/R-717 Cascata x R-717 “Booster” By L. Tomaz Cleto – Yawatz Engenharia - 2007
  • 19. Data for comparison of pipe cross section areas Common calculation data: Capacity 250 kW Temperature Drop in Dry Suction 0.8 K Line: ∆T Temperature Drop in Wet return 0.8 K Line: ∆T Circulating Rate (Liquid Pump) 3 Velocity in Liquid Line 0.8 m/s Equivalent Pipe Length 50 m Evaporating Temperature -40 oC Condensing Temperature -15 oC By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 20. Comparison of pipe cross section area Dry suction / Liquid lines By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 21. Comparison of pipe cross section area Wet return / Pumped Liquid lines By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 22. Comparison of pipe cross section area Dry suction / Liquid lines Index 5% 95% Liquid Suction 4% 96% CO2= 30% 70% R-134a R-717 R-744 By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 23. Comparison of pressure and subcooling produced in liquid risers Refrigerante R-134a R-717 R-744 Pressure produced in liquid riser ”∆p” bar 0.418 0.213 0.329 Subcooling produced in liquid riser ”∆ t ” K 14.91 5.21 0.88 CO2 reciever H=3m ∆p ∆t By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 24. Safety Valves CO2 expansion - phase changes +31 oC 31.0ºC Supercritical Vapor - 50 bar Liquid Vapor - 35 bar Liquid - 20 bar Pressure (bar abs) Sólido -Liquido Liquido - Vapor 50% solid CO2 at 0% solid CO2 at the Sólido the triple point triple point -56.6 oC 5.2 bar 3% solid CO2 at the Solid - Vapor triple point Vapor -78.4 oC Enthalpy By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 26. CO2 Expansion – Trapped Liquid Relative liquid volume Volume Change Temperature By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 27. R-744/R-717 – Cascade System No se puede mostrar la imagen. Puede que su equipo no tenga suficiente memoria para abrir la imagen o que ésta esté dañada. Reinicie el equipo y , a continuación, abra el archiv o de nuev o. Si sigue apareciendo la x roja, puede que tenga que borrar la imagen e insertarla de nuev o. By John Ritmann – York Refrigeration - 2004
  • 28. Water Solubility Water Solubility – Vapour Phase Water Content (ppm)/ CO2 + kg of Refrigerant CO2 + Water Ice CO2 + Water Vapour Temperature By Finn Broesby Olsen & Niels P Vestergaard – Danfoss AS - 2004
  • 29. R-744 (CO2) as REFRIGERANT Primary Refrigerant – (Sub-Critical Cycle): Low Temperatures – Cascade System (-30ºC to -55ºC) Higher COP for temperature lower than -35ºC Lower Compressor Displacement Small refrigerant lines Low Toxicity ( ASHRAE Standard 34 - Class - A1 – TLV = 5000 ppm > HFCs) No flammable High Pressure(40 - 60 bar) New Technologies (Some conceptions from “Freon” Systems) Higher Water Solubility
  • 30. R-744 (CO2) as REFRIGERANT Secondary Refrigerant: IntermediateTemperatures (-20.0ºC to 0.0ºC) Two-phase Flow High Heat Transfer Coefficient Very Small Refrigerant Lines
  • 31. Industrial Refrigeration Market Industrial Refrigeration – EU JCI-York – DK (Sabroe/ Frick) GEA-Grasso Danfoss Alfa-Laval Star Refrigeration FMC - Frigoscandia Mayekawa (Japan) IIR-IIF USA to support CO2 solutions
  • 32. Market Trend Industrial Refrigeration in Brasil Food Industry R-717, Ammonia and NH3 PHE Chillers – Reduced Refrigerant Charge Secondary Fluids (-15.0ºC a 0.0ºC) R-744 - ??? – Great Future! Legislation/ Safety NBR 16069:2010
  • 33. Market Trend Industrial Refrigeration in Brasil Process Industry/ Industrial Air Conditioning R-22 – Almost “Naturally” Phased Out R-717 Plants HCs – (R-1270) – Classified Area R717 – PHE Chillers – Reduced Refrigerant Charge HFCs – Chilled Water Systems
  • 34. Natural Refrigerants in Brasil (2010) More than 80% of the food industry using R-717 plants. Hundreds of R717 PHE Chillers: Mainly for Process and Food Industry. Very few in air conditioning for office buildings. 4 Supermarkets using PHE chillers and secondary fluids (LT/ MT/ AC). Few plants using HCs (Chemical Industry). 1 R-744/R-717 cascade system for food industry. 1 R-744/R-404A cascade system for supermarket. 2-3 new projects using R-744 cascade system for distribution centers.