SlideShare uma empresa Scribd logo
1 de 12
Baixar para ler offline
Nexus 1262/1272      ®



                       Accu-Measure™                               High Performance Utility Billing Meters
                       Auto-Calibrating
                          Metrology
                                                                   With Communication & Advanced Power Quality



                                                                                                            Nexus® 1272
                                                                                                            Performance Meter with
                                                                                                            Advanced Power Quality
                                                                                                            & Communication


                                                                                                            Nexus® 1262
                                                                                                            Economical Meter with
                                                                                                            Advanced Communication




                                                                             • 0.06% Watt/Hr Revenue Meter
www.electroind.com




                                                                             • Auto-Calibrating Metrology

                                                                             • Multi-Point CT & PT and Loss Compensation
                         New! Total Web Solutions
                                                                             • Advanced Power Quality Recording
                        WebExplorer WebReacher WebXML
                          WebAlarm WebMod WebDNP
                                                                             • Eight Totalizing Registers

                                              XML Web Server
                                                                             • Data Logging & Event Recording
                                              Email on Alarms
                                           DNP 3.0 over Ethernet
                                                                             • Unique Powerful Display Configurator

                                                                             • Multiple Communication Paths
                     For Smart Grid and Intelligent
                                                                             • Combination Modem & Ethernet
                        Substation Applications



                             Electro Industries/GaugeTech                                                             MV90
                             The Leader in Power Monitoring and Smart Grid Solutions                                  Compatible
Accu-Measure Auto-Calibrating Metrology


       The Nexus® 1262/1272 meters are designed for demanding smart grid and intelligent substation applications. They provide one
of the most profound analyses of electricity available in a socket meter. The units offer extensive advanced monitoring features to meet
the most critical power monitoring requirements. Using advanced DSP technology, the Nexus®’ measure immediate and stored revenue
power data coupled with superior power quality and communication. To meet the sophisticated standards required by utility companies
and de-regulated power providers, the Nexus®’ basic package starts where most other meters end. Standard features in Nexus® units
provide the ability to meet advanced metering needs for the future.


Accu-Measure™ Auto-calibrating metrology                                   Load Aggregation/Universal Metering
       EIG’s Accu-Measure™ Auto-Calibrating Metrology provides unmatched        Using      standard   pulse
                                                                                              ®
accuracy.                                                                  inputs, the Nexus 1262/1272
     •	 Energy and Power Accuracy to Within 0.06%                          can count pulses from external
     •	 Auto-calibration over Time                                         meters and accumulate usage.
     •	 Automatic Temperature                                              The pulse inputs can be used
        Drift Adjustments                                                  to totalize electrical usage and
                                                                           utility values, such as water or
4 Quadrant                                                                 gas use data.
measurement                                                                  •	 8 Pulse Inputs
       The unit is a full four quad-                                         •	 Individual Accumulating Registers
rant meter and gathers hour data                                             •	 4 Totalizing Registers (Add or Subtract)
information in every quadrant.
     •	 kWh Delivered and                                                  CT & PT Compensation
        Received                                                                The Nexus® units compensate for errors in current transformers and
     •	 kVAh in Each Quadrant                                              potential transformers.
     •	 kVARh in Each Quadrant                                               •	 Voltage Compensation
     •	 Q Hours                                                              •	 Multipoint Current
                                                                                 Compensation
Time of Use                                                                  •	 Multipoint Phase Angle
       The    1262/1272      offers                                              Compensation
robust time of use functionality.                                            •	 Better than 0.01%
Standard capabilities include:                                                   Resolution
     •	 8 TOU Schedules
     •	 4 Seasons/Year                                                     Multiple Demand Windows
     •	 20 Year Calendar                                                        The Nexus® 1262/1272 simultaneously monitors five demand structures.
     •	 Prior Month and Prior Season                                        •	  lock Window Demand
                                                                               B                                     •	 Interval Length from 1 Second
     •	  rogrammable Freeze Registers
        P                                                                   •	 Rolling Window Demand                       to Many Hours
                                                                            •	 Predictive Demand                     •	 End of Interval Pulse Output
Transformer                                                                 •	 Thermal Demand                        •	 End of Interval Pulse Input
or Line Loss                                                                •	 Cumulative Demand                     •	 Cold Load Pickup
Compensation
       Loss Compensation adjusts                                           Time Stamped Max. Demands
for both copper and iron losses                                                 The units gather demand information for all power values. Each value is
with a simple user setup.                                                  date/time stamped.
                                                                            •	 kW Demand, Delivered                 •	 kVAR Coincident with kW Demand
Field Test Mode                                                                 Received, Max/Min                    •	 kVA Demand, Max/Min
     •	 Test All Energy Readings                                            •	 kVAR Demand, Delivered               •	 Amps Demand, Max/Min
     •	 Enable/Disable in                                                       Received, Max/Min                    •	 Voltage, Max/Min
        Test Mode
     •	 Preset Accumulators
     •	 Freezable Accumulators
2	

Reliable, Functional and Feature-Rich Metering
Configure Custom Display For Any Application


Unique Display Configurator
     The Nexus® 1262/1272 is designed with one of the industry’s most
advanced LCD display configuration technologies. With this highly
customizable display, choose from multitudes of pre-programmed
display screens and create fully customized displays for any specific
application. Build, from scratch, user display screens as needed that
provide information on anything the meter measures (which is almost
everything). Use the display to view not only electrical, but water or
gas usage. Also use the meter as an aggregator for total usage.
Provide ambient and transformer temperature or any other desired
critical operational data on the display.




                                                                            Custom display configurator to Create
                                                                            Exactly What’s Needed
                                                                              •	 Make Custom Screens Based on Modbus Registers
     01	 kWh
     	Delivered                                                               •	 Make Any Custom Labels

     	      00001.66                                                          •	 Customize Screen Numbering and Order
                                                                              •	 Display Up To 5 Pieces of Information Per Screen
     08/03/10 16:46:45 1       C                                              •	 Display Water, Gas and Other Types of Usage
                                                                              •	 Add Diagnostic Information


                                                                            Normal Mode
                                                                              •	  Wh Delivered and  Received	
                                                                                 k                                      •	 kVARh Delivered and Received
                                                                              •	 kVAh Delivered and  Received	          •	 Peak Rolling Window Demands
                                                                              •	 Peak Block Window Demand


3 Display Modes/75 Screen Slots                                             Time of Use Mode
     The meter’s memory has 75 slots for custom and/or pre-programmed         •	 kWh and kW Demand Delivered and Received Total
screens. These slots can be allocated to any view mode with any number of     •	  VARh and kVAR Demand Delivered and Received for Each Register
                                                                                 k
slots used in each of the modes.                                              •	  VAh Delivered and Received for Each Register
                                                                                 k
                                                                              •	 kVAh Delivered and Received Total


                                                                            Pre-configured Diagnostic Screens
                                                                                 Select from a large offering of diagnostic screens such as:
                                                                              •	 Voltages	                              •	 Phase Angles
                                                                              •	 Harmonic Magnitudes	                   •	 Firmware Versions
                                                                              •	 Meter Status	                          •	 Phasor Diagram
                                                                              •	 	 er Phase Amps	
                                                                                 P                                      •	 Watts/VARs
                                                                              •	 Many More Diagnostic Screens Available


                                                                            Infrared Test Pulse
                                                                                 The meter provides an infrared test pulse that can pulse for +Watt-Hour,
                                                                            -Watt-Hour, +VAR-Hour, -VAR-Hour and VA-Hour. This pulse uses a time modu-
                                                                            lated pulse integration, allowing the pulse to be accurate during short duration
               Highly configurable display assignments                      pulse tests using industry accepted reference standards.


     	3
Advanced Communications and I/O Capabilities


 Standard multi-port                                    Control Capabilities                                     Total Web Solutions—
 Communications                                           •	 ElectroLogic™ Provides User-definable               Providing Advanced
      •	 Optical Port                                         Control Outputs                                    Metering Data Integration
      •	  RS485 Serial Ports
         2                                                •	 Action and/or Alarm on Abnormal Condition           With the Web
      •	 Modbus RTU/ASCII                               •	 Action on Boolean Logic Combinations of                  Total Web Solutions is an advanced
      •	 DNP 3.0                                              Inputs or Electrical Conditions                    Ethernet communication architecture that
      •	 Speeds Up to 115k bps                                                                                   lets you design custom webpages, display
                                                        DNP 3.0 Level 2 Plus                                     metering data and host your meter power
 Optional Communications                                     The Nexus® 1262/1272 provides the industry’s        information website directly on a Nexus®
      •	 Dial-Out modem (56k) with Battery              most advanced DNP 3.0 protocol implementations.          meter. The Nexus® meter directly hosts the
            Backed Outage Reporting                     DNP 3.0 is available on the serial and Ethernet ports.   web data without any need for dedicated
                                                                      ®
      •	 10/100BastT Ethernet                           EIG’s Nexus       1262/1272 complies with all DNP        server software, ActiveX Controls or Java
      •	 Ethernet/Modem combo                           Level 1 and Level 2 certification requirements PLUS      Applets. The meter does the data collection,
                                                        a host of additional features including:                 the formatting and the page hosting.
 Combination Modem                                        •	 Up to 136 Measurements:
  Web Solution                                               64 Binary Inputs, 8 Binary Counters,               Advanced Features Include:
           This option allows you to access the meter         64 Analog Inputs Mapped to DNP Static Points         •	 Fully Customizable Webpage Development
 through the web and through a modem for dial-up              in the Customizable DNP Point Map                    •	 Direct Webpage Hosting With Live Readings
 communication. Features include:                         •	 Up to 16 Relays and 8 Resets: Can Be                  •	 Multiple Meter Hosting
      •	 56k Modem                                            Controlled through DNP                               •	 Read Direct From Meters (No Server
      •	 10/100BastT Ethernet                             •	 Report-By-Exception Processing: (DNP                      Software Needed)
      •	 Total Web Solutions (Web Server)                     Events) Deadbands Can Be Set on a                    •	 No Active Controls or Java Downloads
      •	 Email on Alarm                                       Per-point Basis                                      •	 IT Dept Friendly. Works Through Firewalls;
      •	 Does Not Support Battery for                     •	 250 Events in Combinations of Four Events:                Low-Cost/High Functionality
            Outage Reporting                                  Binary Input Change, Frozen Counter,                 •	 Instant Alarm Emails – Direct from the Meter
                                                              Counter Change, Analog Change
 Standard I/O                                             •	 
                                                             Freeze Commands: Freeze, Freeze/No-Ack,             WebExplorer
      •	 IRIG-B 1 msec Time Synchronization to                Freeze with Time, Freeze with Time/No-Ack,         (Directly Host Metering Data)
            GPS Satellite Clock                               scheduled Freeze Command                                EIG’s WebExplorer provides you with direct
      •	 4 Internal KYZ Pulse Outputs                     •	 
                                                             Freeze with Time Command:                           access to all power data through Internet Explorer
      •	 8 KYZ Pulse/Status Inputs                            Enables the Nexus® Meter to Have Internal          in standard HTML format, without needing to down-
                                                              Time-driven Frozen Counter and Frozen              load ActiveX controls or Java applets. WebExplorer
 Optional External I/O                                        Counter Event data                                 is fully programmable, so you can customize
           Connect multiple external I/O Modules for      •	 Third Party Certification is Available              your own SCADA quality webpages, graphics and
 enhanced I/O capability.                                                                                        configurations.
      •	     Analog Outputs                                                                                        •	 Easily Incorporated Into Any Existing Web
      •	     Analog Inputs                                                                                             Applications
      •	     Digital Status Inputs                                                                                 •	 Fully Programmable Webpage Generator
      •	     KYZ Outputs                                                                                           •	 Brings in Direct XML Links, Displaying Many
      •	     Relay/Alarm Outputs                                                                                       Meters on One Page


                                                                                                                 WebXML
                                                                                                                      Creates Real Time Data in XML Format.
                                                                                                                 WebXML allows the Nexus® meter to gather data
                                                                                                                 from the Nexus® Host or through other meters and
                                                                                                                 put the data directly into an XML format. This allows
                                                                                                                 you to share data through the web with multiple
                                                                                                                 applications and create custom webpages, using
                                                                                                                 WebExplorer.
 4	

	WebExplorer	                                                               WebXML	                                                WebReacher
Total Web Solutions


                                                          WebAlarm – Email Alerts                                          features are available simultaneously. Even with DNP
                                                               EIG’s WebAlarm sends real time email alerts via             3.0 over the Ethernet, you still have access to multiple
                                                          the Internet to up to 9 recipients simultaneously for            Modbus sockets, email alarms, web servers and
                                                          any combination of event notifications.                          many other communication features.


                                                                                                                           Webmod
                                                                                                                           (Open Architecture 3rd Party Integration)




     WebXML technology is easy to configure and
extremely flexible. With WebXML, your data is instantly
available to a host of software applications including
Internet Explorer, Excel, Power Point and Word.             •	 Real Time Alerts
  •	 Automatically Process and Present Data In              •	 Simultaneous Emails to Multiple Recipients
      Readable XML Format                                   •	 Update Users on Virtually Any Abnormality
  •	 Add Scale Factors, Multipliers or Other                •	 Uses Standard SMTP — Just Assign Email
      Desired html Capability                                   Addresses
  •	 Display Data From Host Meter and/or Any                •	 Shows the Last 10 Emails on Website for                              The 10/100BaseT design allows the unit to
      Other Meter Using Modbus RTU or TCP/IP                    Later Investigation                                        speak with 12 simultaneous sockets of Modbus TCP.
      (WebReacher)                                                                                                         EIG’s WebMod features Modbus TCP open protocol
  •	 Customized Programming                               Webdnp                                                           that can be easily integrated with most other software
  •	 Easily Viewed By Different Applications                   Using this feature, you can gain access to the              or hardware. And, with the built-in Modbus data con-
  •	 Modbus Data Concentrator                             meter speaking native DNP over Ethernet. This allows             centrator, you can poll up to 8 devices or 512 unique
                                                          the unit to open an exclusive network socket for DNP             polling items from any device that can speak Modbus
WebReacher                                                3.0. Using this unique technology, all other meter web           RTU and/or Modbus TCP protocols.
     With EIG’s exclusive WebReacher technology,
you can now access remote meters around the                                                                                 View data from multiple meters generated from
                                                                                                                            the Master Meter in your web browser.



                                                                                                                                        WebXML provides
                                                            Meter 124                                                                 totalized energy usage
                                                                                                   Internet Explorer

                                                                                            WebMod TCP/IP



                                                                                                                                                            Web
                                                                                                                                                                M      od T
                                                                                                                                                                           CP/I
                                                                                                                                                                                P




                                                                                               P/IP
                                                                                                                                                         We




                                                                                            TC
                                                                                       od
world, retrieve data and consolidate it onto one                                                                                                                                    Meter 115
                                                                                                                                                            bM




                                                                                      M
                                                                                  eb
                                                                                                                              /IP




                                                                                 W
                                                                                                                                                           od




webpage or website without any separate software
                                                                                                                              P
                                                                                                                           TC




                                                                                                                                                               TC




SCADA package or client-side ActiveX controls or
                                                                                                                          d




                                                                                                                                                                  P
                                                                                                                       Mo




                                                                                                                                                                 /IP




Java applets.
                                                                                                                       b
                                                                                                                    We




  •	 No Additional Software Application Costs                Meter 31
  •	 No Server System Required
  •	 No Complex Integration
  •	 No Costly Point Charges
      (Up to 32 Devices)                                       Web Solutions allows a meter              Meter 87
                                                               to display data from many
                                                                                                                                                                      Meter 14
                                                               remote meters.


     	5

	               WebAlarm	                                                   WebMod	                                                         WebDNP
Nexus® 1272 Advanced Power Quality Analysis Pinpoints Electrical Reliability Issues


       The processing capability and accuracy of the Nexus® 1272 makes
it possible to gather power quality information with unmatched precision.
The Nexus® 1272 is ideally suited for application on all critical loads. From
health care to micro-electronics, the 1272 has what it takes to capture
every anomaly. This insures that when there is a power problem, you have
the information required to act. All Power Quality logs are time stamped to
the nearest millisecond to insure accurate recording. Nexus®’ Advanced
Download Logic collects only new data to minimize download times.


Event/Out of Limit Log
     •	 Records 1024 Events                      •	 Extensive Limit Setting Capabilities
     •	 Out of Limit Recording                       with Multiple Limits per Selected
     •	 High-Speed Input Event Recording             Quantity
     •	 Outage Detection


Waveform Log
       The waveform recording capability of the Nexus® is unparalleled by any meter.
Waveform records of this quality have historically been reserved only for transmission
lines. The power of the Nexus® 1272 now makes this quality available to your critical
customers.
     •	  xtraordinary Resolution through
        E                                        •	 Up to Six Channels
        16 bit A/D Input                         •	 Voltage and Current Triggers
     •	 Sample Rates from 16 to 512              •	 E xternal Event Trigger
        Samples per Cycle                        •	 Voltage Surge/Sag Recording
     •	 Total Recording Times over 100           •	 Current Fault Analysis
        Seconds


Harmonic Distortion Analysis                                                               CBEMA/ITIC Log
     •	 Log Harmonics into Historical Log for Later Analysis                                    The separate CBEMA/ITIC Log captures all voltage transients
     •	 Recorded Waveforms Provide Harmonics to the 255th Order                            that fall outside these standards. The onboard log holds 1024 events.
     •	 View Waveform Record                                                               The data is downloaded to a separate log in the meter database for
                                                                                           easy analysis. See all voltage disturbances on one screen through the
                                                                                           Communicator EXT software.
                                                                                             •	 Sag/Swell Analysis
                                                                                             •	 Transient Recording




6
Advanced Reporting and Analysis                                              System Performance and Reliability Analysis


    The accuracy and precision of the Nexus® 1272 coupled with
its extraordinary logging capability makes it an ideal tool for system
performance and reliability analysis. For the first time, users have
the accuracy and precision of a digital fault recorder at the revenue-
metering site without the expense. The Nexus®’ 16-bit accuracy
and resolution for waveform records actually exceeds many digital
fault recorder products. Combine the Nexus® 1272 with EIG’s suite
of software solutions to further expand the level of understanding
during any monitoring situation.


AiReports –                               Communicator EXT
PQ Analysis                               Fault Analysis
     AiReports provides automated           •	 Compares Multiple Fault
analysis and reports (1272 Only) for            Records
abnormal events.                            •	 Measures Waveform Traces
  •	 Uses Artificial Intelligence           •	 
                                               Inserts Timing Marks to
  •	 
     Evaluates All Data from                    Analyze Waveform Transients
            ®
      Nexus Monitor                         •	 Views CBEMA Logs                       Download the data and open the         At The Customer
  •	 Rates Events for Severity                                                  files with Communicator EXT. Compare             When that key customer calls,
  •	 Identifies Probable Causes        At The Interchange                       multiple channels. Measure amplitudes       simply perform a download from the
  •	 Identifies Possible Impacts          Point                                    and timing with millisecond resolution.     Nexus® 1272. In a few minutes, all the
  •	 Recommends Corrective                     Nexus® gives you the power          See system reliability events that lasted   data related to any event is on your
      Actions or Solutions                of a sequence of events recorder on      for several seconds.                        desktop. A completed report is ready
  •	 Prepares and Formats Report          every transmission line or interchange                                               to review internally or email to the cus-
      of All Power Quality Events         point. Nexus® is always watching         Test Protective                             tomer. Probable causes are identified
  •	 
     PQDIF File Format Converter          and has extended memory capability,      Equipment                                   and corrective actions recommended.
      Allows Nexus® Data to be            which can record multiple faults, or          Need to test protective equip-              Need to perform a more detailed
      Read by Standard EPRI Power         even frequency swings, during stabil-    ment performance? Simply take               evaluation? Simply open the viewer to
      Quality Viewing Software.           ity problems. Capture all voltages and   the Nexus® record and convert to            look at the waveforms and see exactly
  •	 COMTRADE File Converter            currents.                                COMTRADE format. Insert the file            what happened to voltages and
      Changes Fault Records to                                                     directly to protective test equipment       currents throughout the event. Only
      Standard Fault Analysis File                                                 to verify relay performance.                Nexus® provides precise pictures for
      Formats                                                                                                                  many seconds.



Supported Meter Forms	                                                              Accuracy
 FORM	                 RATED VOLTAGE 	                    HOOKUP                    PARAMETER	ACCURACY

 	 9S	                       0 to 277V	                 3E, 4W, Wye                 	 Voltage	0.02%
 		                              L-N                                                	Current	                                           0.05%
 	 36S	                      0 to 277V	               2½ E, 4W, Wye                 	Frequency	                                         0.001Hz
 		                              L-N	                  with Neutral
                                                                                    	kW	                                                0.06%
 	 45S	                      0 to 480V	                2E, 3W, Delta
 		                              L-L                                                	kWh@1.0PF	                                         0.06%
 	 WB2	
 S      0 to 277V	                                     Programmable                 	kWh@0.5PF	                                         0.10%
 			                                                  (Universal Forms)             	kVAR	                                              0.10%
 	 9A	                       0 to 277	                  A Base Form                 	kVA	                                               0.10%
 		                             L-N
                                                                                    	PF	                                                0.10%	



    	7
Data and Event Monitoring/Recording


Multiple Memory                            System Events Log
Logs                                                The unit records the following
       Nexus® meters provide many logs     system events for security and anti-
to record historical, alarm and system     tampering.
event data. These logs can be used for           •	 Power Up
profiling, recording events and logging          •	 Power Down
electrical power parameters over time.           •	 Password Access
Additionally, using the advanced I/O             •	 Password Modification
available with the product, you can also         •	 Change of Programmable Settings
log process measurements, including              •	 Change of a Run Time
temperature, pressure, flow, etc.                •	  hange of Clock Time by
                                                    C
                                                     Communication (Modbus
Two Historical                                       or DNP)
                                                                                               Historical Trending
Trend Logs                                       •	 Test Mode Usage
       These logs allow you to trend             •	 Meter Resets (Logs, Max/Min,
virtually any electrical parameter over              Energy)
time. This includes all electrical and
I/O parameters.                            Input Status Log
     •	  p To 64 Values per Log
        U                                           This log records when a digital
     •	 Programmable Trend Times           status change occurred in either the                Replace Conventional
                                                                                                    Chart Recorders
     •	 Provides Magnitude and             internal or external inputs.
           Duration of Event                 •	      Status Log for External Events
     •	 Millisecond Resolution               •	      I
                                                     nternally Labeled to Define
     •	 2 Separately Programmable Logs               Events
     •	 Separately Recorded Time Base
     •	 Records Alarms For Electrical 	    Control Output Log
           and I/O Channels                         This log records the logic and
                                           state that triggered a control output.
Out of Limits Log                          The graphical log shows all the steps
       This log records all out-of-limit   that led up to the event.
alarms, including the magnitude and              •	 Displays Pre- and Post-
the duration of the alarm.                           Analysis
                                                 •	 nternally Labeled to Define
                                                    I
                                                     Events
                                                 •	  dvanced I/O Analysis
                                                    A                                                 View Alarms, Status Changes and Control Events


     Logging Specifications

      Model            Memory       Historical         Historical       CBEMA /       Out of Limit        Waveform    Output Log 2     Input           System
                                      Log 11            Log 2 1          ITIC 2          Log 2              Log 3                      Log 2           Events 2

      1272            Standard      85 Days             133 Days           512            1024               63           256          1024             1024
      1272            Advanced      555 Days            133 Days           512            1024               95           256          1024             1024

      1262            Standard      69 Days            32 Days             N/A             512               N/A          512          1024             1024
      1262            Advanced      480 Days           133 Days            N/A             512               N/A          512          1024             1024


      1	   Assumes Logs store 4 scaled energy readings every 15 minutes                   3	    Number of Waveform Records. Each record may be from 		
                                                                                      	         8 to 64 cycles in duration depending upon meter setup
      2	   Number of Events Recorded (assumes 14 parameters monitored)




8
Dial-Out On Alarm (INP2)


Dial-Out on Outage
     The INP2 modem has a dial-out circuit with a battery that detects when
                                                                                                                    Event
voltage is lost and dials out to provide outage notification. Additionally, the circuit
                                                                                              Meter
can be configured to dial out when many other circumstances occur. The Nexus®                Dials Out
                                                                                             on Event
1262/1272 dials to the EIG Dial-In Server which allows users to be paged or emailed
with notification of events. When the modem option card is installed, the meter
also includes a gateway port. This allows the meter to act as a master for up to 7
additional meters and dial out on alarm for any of these meters.
                                                                                                                                     RS485
                                                                                                                                   Connection
Dial-Out for Other Events
     The meter will dial out for the following circumstances:                              Telephone
  •	 Limits/Status Change	                     • 	 Control Output Change                                                                                Dial-out
                                                                                                                                                        Modem
  •	 High Speed Input Change	                  • 	 Cycling of Control Power                                                                             INP2
  •	 Waveform Record Capture	                  • 	 Password Failure on a Call              Server
                                                                                          Receives
  •	 CBEMA Power Quality Event		                   Coming into the Modem                   Alarm

  •	 Control Output Change	                    • 	 Meter Communication Failure




                                                                                                                                                Server Provides:
                                                                                                                                             • Alarm Notification
                                                                                                                                             •  ogging 
                                                                                                                                               L
                                                                                                                                               Download
                               Modem Call In Event                                                                                           • Automated Alerts




                                   Visual Alarm




Dial-In Server Capabilities
     The EIG Dial-In Server will record all notifications, accept downloads from the                     Automatic Notification Via Pager,
                                                                                                              Cell Phone or Email
meter and allows users to be notified by email and paging automatically. Features of
the Dial-In Server include:
  •	 Unlimited Meters	                         •	 Scalable Multi-server Architecture
  •	 Email Notification	                       •	 Paging Notification
  •	 Audible System Alarm




                                                                                                                     Dial-In Settings



     	9
     Dial-Out Logic
Dimensions and Mounting	


                        Nexus® 1262/1272                                                                  Nexus® 1262/1272
                   Switchboard Case Front View                                                       Switchboard Case Back View


                                                                                                                  6.13” (15.57 cm)




                                                                                                                         Y K Z
                                                                                                                                 | Y CH2 Z | Y CH3 Z | Y CH4 Z |
                                                                                                                                      K         K         K                 S (1) (+)
                                                                                                                                                                                                 8.5”
                                                                                                                          CH1                                               Gateway

                                                                                                                                                                                                (21.6
                                                                                                                  (-) (+) S (-) (+)
                                                                                                                          |           |   S (-) (+)
                                                                                                                                                      |   8 7 6 5 4 3 2 1 C                      cm)
                                                                                              4.38”




                                                  9.25 (234.95 mm)
                                                                                                                  IRIG-B COM1              COM4                HIGH SPEED


                                                9.25”                                        (11.11           L N PE

                                                (23.5                                          cm)
                                                                                                              Power In                                             Network Phone Line




                                                 cm)
                                                                                                                                                                                                    9.0”
                                                                                                                                                                                                   (22.9
                                                                                                                                                                                                    cm)
                                                                                                               Vc         Ia - Hi             Ib - Hi          Ic - Hi                  Va
                                                                                                                +                +                        +             +               +
                                                                                                         Vn              Lo                  Lo                Lo              Vb
                                                                                                          +               +                   +                +                 +

                                                                                             0.19”
                                                                                             (.048
                                                                                              cm)
                                                                                                                          5.6” (14.22 cm)
                     6.85” (17.4 cm)
                       6.85 (173.99 mm)
                                                                                                                         6.58” (16.51 cm)


            Nexus® 1262/1272                                             Nexus® 1262/1272                                                                     Nexus® I/O Modules
               Front View                                                   Side View                                                                             Front View



                                                                                                                                                                                                    1.10” (2.8cm)

                                                                                                                                                                                                  0.63” (1.60cm)


                                                                                                                                                                                                        1.31” (3.33cm)
                                                                                                               6.96”
                                                                                                              (17.68
                                                                                                               cm)




                                                                                                                                                                                  2.20”
                                                                      3.68” (9.35cm)                                                                                            (5.6cm)
                6.16” (15.64cm)                                            6.00” (15.24cm)                                                                                      3.40”
                                                                                                                                                                              (8.63cm)

                 Nexus® 1262/1272                                                                        Nexus® 1262/1272 A Base
                 A Base Front View                                                                              Side View

                                                 0.87” (2.21cm)
                                                                                                                             4.23”
                                                                                                                          (10.74cm)




                                             10.17”
                                           (25.83cm)




                                                                                                                                                                                       2.00”
                                                                                                                                                                                     (5.08cm)
                7.00” (17.8cm)                                                                                                    6.18” (15.7cm)

10
Specifications
Wiring Diagrams
FORM: 9S (TRANSFORMER RATED)
SERVICE: WYE, 4WIRE                            3
                                                                     Switchboard Mount
3 PTs, 3 CTs
                                                    N
    LINE                                                1
                                                                                                                                                                             SERVICE: WYE, 4WIRE
8! 8  8                                                                                                                                                                3 PTs, 3 CTs

                                                2                                                                                                                                   3
                                                                                      Y K Z
                                                                                       CH1         | Y CH2 Z | Y CH3 Z | Y CH4 Z |
                                                                                                        K         K         K                    S (1) (+)
                                                                                                                                                 Gateway

                          1!
                                                                              (-) (+) S (-) (+)
                                                                                      |               |   S (-) (+)
                                                                                                                      |   8 7 6 5 4 3 2 1 C                                                     N
                                                                              IRIG-B COM1                  COM4                HIGH SPEED
                                                                                                                                                                                                                  1
                                                                          L N PE
                                                                          Power In                                                      Network Phone Line




                          1 
                                                                                                                                                                                    2



                                                                                                                                                                 Va
                          1                                              Vc         Ia - Hi                 Ib - Hi               Ic - Hi
                                                                            +                     +                       +                  +                   +
                                                                 Vn                   Lo                      Lo                   Lo                 Vb
                                                                 +                    +                       +                     +                   +




                                
                                                                                                                                                                                            LINE
                                8
                                                                                                                                                                                           !           
                                8 
                                                                                                                                                 Hi
                                8!
                                                                                                                                        lc Lo

                                                                                                                              Hi
                                                                                                                                                                                                            CTs
                                                                                                                  lb Lo
                                                                                                      Hi
                                                                                          la Lo


                                                                                                                                                                              PTs
                                                                                                                                                                       8=

                                                                                                                                                                       8

                                                                                                                                                                       8?


                        Form 9S 4-Wire Wye                                                                                                                             

    LOAD
   FORM: 45S (TRANSFORMER RATED)
   SERVICE: DELTA, 3WIRE                            3                                                                                                                                       LOAD

   2 PTs, 2 CTs
       LINE
                                                                 Switchboard Mount
    8! 8  8
                                           2            1
                                                                                                                                                                            SERVICE: DELTA, 3WIRE
                                     1!                                                                                                                                    2 PTs, 2 CTs

                                                                                                                                                                                            3
                                                                                Y K Z
                                                                                 CH1       | Y CH2 Z | Y CH3 Z | Y CH4 Z |
                                                                                                K         K         K                       S (1) (+)
                                                                                                                                            Gateway

                                     1
                                                                      (-) (+) S (-) (+)           S (-) (+)        8 7 6 5 4 3 2 1 C
                                                                              |
                                                                      IRIG-B COM1
                                                                                              |    COM4
                                                                                                              |         HIGH SPEED



                                                                 L N PE
                                                                 Power In                                                         Network Phone Line


                                                                                                                                                                              2                               1




                                                                  Vc            Ia - Hi               Ib - Hi                 Ic - Hi                       Va
                                                                      +                   +                       +                     +                   +
                                                            Vn                  Lo                    Lo                      Lo                 Vb
                                                            +                   +                         +                   +                  +
                                     8

                                     8!

                                                                                                                                                                                            LINE

                                                                                                                                                                                        !           



                                                                                                                                            Hi
                                     8 
                                                                                                                                  lc Lo

                                                                                              Hi
                                                                                                                                                                                                        CTs
                                                                                     la Lo




                                                                                                                                                                            PTs
                                                                                                                                                                      8=



       LOAD                                                                                                                                                           8?




                        Form 45S 3-Wire Delta
                                                                                                                                                                                            LOAD

 	11
Specifications
 SENSE INPUTS:                                           (18 to 60)Vdc. Burden 9W max.                         •  n Resistance: 23-35Ω
                                                                                                                 O                                                           APPROVALS
 CURRENT (ac)                                          • Separate power cord.                                  •  eak Voltage: 350V DC
                                                                                                                 P                                                           • EC 60687 - KEMA Certified
                                                                                                                                                                               I
 •  ransformer (CT) rated
   T                                                   •  witchboard meter is always separately powered
                                                         S                                                     •  ontinuous Load Current: 120mA
                                                                                                                 C                                                           • EC 62053-22 - KEMA Certified
                                                                                                                                                                               I
 •  or 3 current inputs depending on Form
   2                                                     (option SE or DE).                                    •  eak Load Current: 350mA (10ms)
                                                                                                                 P                                                           •  alifornia ISO
                                                                                                                                                                               C
   (Ia, Ib, Ic)                                        ISOLATION                                               •  ff State Leakage Current @350V DC: 1: µA
                                                                                                                 O                                                           •  Y State Public Service Commission
                                                                                                                                                                               N
 • Class 2 – 1A nominal, burden 0.000312VA@2.5A        •  ll Inputs and Outputs Isolated to 2500 Volts
                                                         A                                                     •  pto Isolation: 3750V rms (60Hz, 1 min.)
                                                                                                                 O                                                           •  SDA Technical Standards Committee Rural
                                                                                                                                                                               U
 •  lass 10, 20 – 5A nominal, burden
   C                                                   •  om Ports Isolated From Each Other to 1000 Volts
                                                         C                                                                                                                     Development Unit
                                                                                                               CLOCK TIMING
   0.0125VA@25A                                        SENSING                                                                                                               •  Mi - Brazil
                                                                                                                                                                               N
                                                                                                               • nternal Clock Crystal - Accuracy Better than
                                                                                                                 I
 • 0.1% of nominal pickup current                      •  ccu-Measure™ Technology
                                                         A                                                                                                                   •  EEE - Brazil
                                                                                                                                                                               C
                                                                                                                 2 Minutes per Month
 • 120% over range of Meter Class                      •  6 bit A/D Inputs
                                                         1                                                                                                                   •  nion Fenosa - Spain
                                                                                                                                                                               U
                                                                                                               • 
                                                                                                                 IRIG-B Input for Synchronizing to External GPS
 •  urrent surge withstand (at 23°C) - 100 Amps
   C                                                   •  rue RMS
                                                         T
                                                                                                                 Clock Signal - Accuracy Better than 1 msec                  •  AM - Endesa Chile
                                                                                                                                                                               C
   for 10 seconds, 300 Amps for 3 seconds,             •  Channel Sample  Hold
                                                         8
                                                                                                                 per Month                                                   •  lectric Power Test Research Institute of China -
                                                                                                                                                                               E
   500 Amps for 1 second                               MEMORY                                                  •  ine Sync - Accuracy Better than 1 Second
                                                                                                                 L                                                             China Southern Power Grid
 VOLTAGE (ac)                                          •  ll Meter Setup Parameters, Measurements
                                                         A                                                       per Month                                                   •  hina Northwestern Electric Power Research
                                                                                                                                                                               C
 • 
   Blade powered unit, standard voltage (option S):       Logs Contained in Nonvolatile RAM                   ENVIRONMENTAL                                                   Institute
   480Vmax Phase to reference (Va, Vb, Vc to Vref).    STANDARD COMMUNICATIONS                                 •  perating Temperature: (-40 to +85)°C
                                                                                                                 O                                                           •  CEPRI - Beijing
                                                                                                                                                                               N
   Burden total 12VAmax (including power supply)       •  CD Display
                                                         L                                                     •  isplay Temperature: (-20 to +60)°C
                                                                                                                 D                                                           •  EPRI - China State Grid
                                                                                                                                                                               C
   600Vmax Phase to Phase (Va to Vb, Vb to Vc,         • R Port
                                                         I
   Vc to Va)                                                                                                   •  aintight Lexan Cover (Socket)
                                                                                                                 R                                                           •  TS - Korea
                                                                                                                                                                               A
                                                       •  wo RS485 Serial Ports
                                                         T
 •  lade powered unit low voltage (option LV):
   B                                                                                                           • Temperature Specifications to Indirect Light
                                                       •  odbus RTU, Modbus ASCII, DNP 3.0
                                                         M                                                                                                                   COMPLIANCE standards
   69Vmax between Vref and Va, Vb, Vc inputs.                                                                  SECURITY
                                                       •  ata Speeds of up to 115k bps
                                                         D                                                                                                                   •  NSI C12.20 	
                                                                                                                                                                               A                   Accuracy
   Burden total 12VAmax (including power supply)                                                               •  ardware Lock Secures Meter Settings
                                                                                                                 H
   120Vmax between Va, Vb, Vc inputs                   •  ight High-Speed Input Channels
                                                         E                                                                                                                   •  NSI/IEEE C37.90.1	Surge Withstand
                                                                                                                                                                               A
                                                                                                               •  wo 10-Character Passwords
                                                                                                                 T                                                           •  NSI C62.41	
                                                                                                                                                                               A                   Surge Immunity
 •  xternally powered units (options SE, DE):
   E                                                   OPTIONAL COMMUNICATIONS                                 •  ne Password Controls Access to Read
                                                                                                                 O
   480Vmax between Vref and Va, Vb, Vc inputs.                                                                                                                               • EC 1000-4-2 	
                                                                                                                                                                               I                   ESD
                                                       •  6K Modem with Dial-Out Capabilities
                                                         5                                                       Meter Digitally
   Burden 0.33VA@576V                                                                                                                                                        • EC 1000-4-3	
                                                                                                                                                                               I                   Radiated Immunity
                                                       • nternal 10/100BaseT Rapid Response™Ethernet
                                                         I                                                     •  eparate Password Controls Access to
                                                                                                                 S                                                           • EC 1000-4-4	
                                                                                                                                                                               I                   Fast Transient
   600Vmax between Va, Vb, Vc inputs                                                                             Program Meter
 • Input impedance 1Mohm/phase.                        •  odem/Ethernet Combo Card
                                                         M                                                                                                                   • EC 1000-4-5	
                                                                                                                                                                               I                   Surge Immunity
                                                       • Modbus TCP and DNP LAN/WAN                            •  dditional 8 level password sequence
                                                                                                                 A                                                           • EC 1000-4-6	
                                                                                                                                                                               I                   Conducted Immunity
 • 20% over range of rated voltage.                                                                              available by user configuration
                                                       INTERNAL 8ch DIGITAL INPUTS                                                                                           • EC 60068-2-6	
                                                                                                                                                                               I                   Vibration (Sinusodial)
 • 2V pickup voltage.
                                                                                                               SHIPPING                                                      • EC 60068-2-27	 Shock Test
                                                                                                                                                                               I
 EXTERNAL POWER SUPPLY                                 •  ype: Self Excited, for Dry Contacts Only
                                                         T
                                                                                                               Weight:                                                       • EC 695-2-1	
                                                                                                                                                                               I                   Resistance to Heat  Fire
 OPTIONS                                               • nternal Wetting Voltage: 12V DC Typical
                                                         I
                                                                                                                                                                             • EC 68-2-1	
                                                                                                                                                                               I                   Cold Test
 •  tandard external (option SE):
   S                                                                                                           Socket: 10 Lbs	          Switchboard: 16 Lbs
                                                       INTERNAL 4ch                                                                                                          • EC 68-2-2	
                                                                                                                                                                               I                   Dry Heat
   (102 to 276)Vac @50/60Hz. 12VA max.                 SOLID STATE OUTPUTS (kyz)                               Dimensions:
                                                                                                                                                                             • EC 68-2-30	
                                                                                                                                                                               I                   Damp Heat
 •  ow voltage external (option DE):
   L                                                   •  ype: Form A or C
                                                         T                                                     Socket: 13 x 10 x 11	 Switchboard: 16 x 14 x 11


  Ordering Information                                (To order, please use this guide)
               		 Model	 Memory	 Form	 Class (Amps)	 Frequency	 Power Supply1	    Optional
               								                                                        Communication
    Option
    Numbers:                               −                          −                           −                            −                              −                             −
    Example:               1272            −             A            −             45S           −            20              −                50            −               DE            −         INP200


	 1272	                                                   S	  9S	                                               2	                             50	                             S	                       X	
		                                                       Std		                                               Amps	                            50 Hz	                   Std Blade Powered	        No Optional Com	
	 1262	   A	  36S	    10	  60	                                                                                                                                               SE	                       INP2	 	
		       Adv		      Amps	 60 Hz	                                                                                                                                           Std Ext	                   Modem	
						                                                                                                                                                                 102-270V AC/DC	             with Dial-Out
			 45S	    20	 	    DE	                                                                                                                                                                            INP200	
				      Amps		    DC Ext	                                                                                                                                                                   10/100BaseT Ethernet
						            18-60VDC	
				    SWB2	      	 	       LV	         INP202	                                                                                                                                                                             	
				 (Switchboard)			 69VAC	             Modem 	
							                Blade Powered	 Ethernet Combo	
			 					                              (No Dial-Out)	
				                                                                                9A						
				                                                                             (A Base)					
                                                                                            1 Switchboard Meter Only Supports SE or DE Options.


  Accessory Options
      O PTIO N A L I / O M OD UL E S                                      POWE R OP TI O NS                                                       S O F TWARE O P TI O NS
      1mAON4	           4 Analog Outputs, 0-1mA                           PSIO	                    I/O Power Supply (Required                     COMEXT3.1C	   ommunicator EXT 3.0 for Windows ©
                                                                                                                                                               C
      1mAON8	           8 Analog Outputs, 0-1mA                           	                        with I/O Module)                                            Single-Computer License (One Site)
      20mAON4	          4 Analog Outputs, 4-20mA                          BAT1	                    External Replaceable Battery for               COMEXT3.MC	                 ommunicator EXT 3.0 for Windows ©
                                                                                                                                                                             C
      20mAON8	          8 Analog Outputs, 4-20mA                          	                        Dial Out on Outage                                                        Multiple-Computer License (One Site)
      4RO1	             4 Relay Outputs                                                                                                           AIEXT.1C	                  A
                                                                                                                                                                              iReports EXT Power Analysis Software
      4PO1	             4 Solid State Pulse Outputs                                                                                                                          for Windows © Single-Computer License
                                                                          M OU N T ING O P TI O NS                                                                           (One Site)
      8AI1	             +/- 0-1mA, 8 Analog Inputs
      8AI2	             +/- 0-20mA, 8 Analog Inputs                       MBIO	                    I/O Module Mounting Bracket                    AIEXT.MC	                  Multiple-Computer License (One Site)
                                                                          	                        Power Supply and Mounting Bracket
      8AI3	             +/- 0-5VDC, 8 Analog Inputs                                                                                               DISEXT.1C	                 D
                                                                                                                                                                              ial-In Server Single-Computer License
                                                                          	                        Required with any I/O Option
      8AI4	             +/- 0-10VDC, 8 Analog Inputs                                                                                                                         (One Site)
      8DI1	             8 Status Inputs, Wet/Dry                                                                                                  DISEXT.MC	
                                                                                                                                                            Dial-In Server Multi-Computer License
                                                                                                                                                            (One Site)
                          Electro Industries/GaugeTech
                          1800 Shames Drive • Westbury, NY 11590
                          1- 877- EIMETER (1- 877- 346- 3837) • E-Mail: sales@electroind.com
                          Tel: 516-334 -0870 • Web Site: www.electroind.com • Fax: 516-338-4741                                                                                              E151702 081811 Rev J

Mais conteúdo relacionado

Mais procurados

Underground Self-Healing Solution
Underground Self-Healing Solution Underground Self-Healing Solution
Underground Self-Healing Solution Schneider Electric
 
Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...
Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...
Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...Steve Houck
 
Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...
Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...
Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...Steve Houck
 
[Case study] Dakota Electric Association: Solutions to streamline GIS, design...
[Case study] Dakota Electric Association: Solutions to streamline GIS, design...[Case study] Dakota Electric Association: Solutions to streamline GIS, design...
[Case study] Dakota Electric Association: Solutions to streamline GIS, design...Schneider Electric
 
Smart Energy in the Data Center
Smart Energy in the Data CenterSmart Energy in the Data Center
Smart Energy in the Data CenterSteve Houck
 
A New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data CentersA New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data CentersSchneider Electric
 
The Intelligent and Connected Data Center
The Intelligent and Connected Data CenterThe Intelligent and Connected Data Center
The Intelligent and Connected Data CenterSchneider Electric
 
Surround the inverter brochure en
Surround the inverter brochure enSurround the inverter brochure en
Surround the inverter brochure enSuman
 
Low power vlsi design ppt
Low power vlsi design pptLow power vlsi design ppt
Low power vlsi design pptAnil Yadav
 
Low Power Adiabatic Logic Design
Low Power Adiabatic Logic DesignLow Power Adiabatic Logic Design
Low Power Adiabatic Logic DesignIOSRJECE
 
Hacking the Conventional Data Center Infrastructure
Hacking the Conventional  Data Center InfrastructureHacking the Conventional  Data Center Infrastructure
Hacking the Conventional Data Center InfrastructureSchneider Electric
 
AMD PowerTune Technology on Workstation Graphics
AMD PowerTune Technology on Workstation GraphicsAMD PowerTune Technology on Workstation Graphics
AMD PowerTune Technology on Workstation GraphicsAMD
 
Adiabatic logic or clock powered logic
Adiabatic logic or clock powered logicAdiabatic logic or clock powered logic
Adiabatic logic or clock powered logicTuhinansu Pradhan
 
神州数码 Jason pan future_clouddatacenterv2
神州数码 Jason pan future_clouddatacenterv2神州数码 Jason pan future_clouddatacenterv2
神州数码 Jason pan future_clouddatacenterv2colderboy17
 
Synched E Harvesting Wireless Sensors For Sensors Expo 2009 Dist
Synched E Harvesting Wireless Sensors For Sensors Expo 2009 DistSynched E Harvesting Wireless Sensors For Sensors Expo 2009 Dist
Synched E Harvesting Wireless Sensors For Sensors Expo 2009 Distswarms_2009
 
Microgrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & powerMicrogrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & powerSchneider Electric
 
Proactive and reactive thermal optimization techniques to improve energy effi...
Proactive and reactive thermal optimization techniques to improve energy effi...Proactive and reactive thermal optimization techniques to improve energy effi...
Proactive and reactive thermal optimization techniques to improve energy effi...GreenLSI Team, LSI, UPM
 
Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...
Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...
Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...Capgemini
 

Mais procurados (20)

Ijetcas14 562
Ijetcas14 562Ijetcas14 562
Ijetcas14 562
 
Underground Self-Healing Solution
Underground Self-Healing Solution Underground Self-Healing Solution
Underground Self-Healing Solution
 
Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...
Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...
Overcoming Rack Power Limits with Virtual Power Systems Dynamic Redundancy an...
 
Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...
Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...
Virtual Power Systems - Intelligent Control of Energy (ICE) and Software Defi...
 
[Case study] Dakota Electric Association: Solutions to streamline GIS, design...
[Case study] Dakota Electric Association: Solutions to streamline GIS, design...[Case study] Dakota Electric Association: Solutions to streamline GIS, design...
[Case study] Dakota Electric Association: Solutions to streamline GIS, design...
 
Smart Energy in the Data Center
Smart Energy in the Data CenterSmart Energy in the Data Center
Smart Energy in the Data Center
 
A New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data CentersA New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data Centers
 
The Intelligent and Connected Data Center
The Intelligent and Connected Data CenterThe Intelligent and Connected Data Center
The Intelligent and Connected Data Center
 
Surround the inverter brochure en
Surround the inverter brochure enSurround the inverter brochure en
Surround the inverter brochure en
 
Low power vlsi design ppt
Low power vlsi design pptLow power vlsi design ppt
Low power vlsi design ppt
 
Low Power Adiabatic Logic Design
Low Power Adiabatic Logic DesignLow Power Adiabatic Logic Design
Low Power Adiabatic Logic Design
 
Hacking the Conventional Data Center Infrastructure
Hacking the Conventional  Data Center InfrastructureHacking the Conventional  Data Center Infrastructure
Hacking the Conventional Data Center Infrastructure
 
AMD PowerTune Technology on Workstation Graphics
AMD PowerTune Technology on Workstation GraphicsAMD PowerTune Technology on Workstation Graphics
AMD PowerTune Technology on Workstation Graphics
 
Adiabatic logic or clock powered logic
Adiabatic logic or clock powered logicAdiabatic logic or clock powered logic
Adiabatic logic or clock powered logic
 
神州数码 Jason pan future_clouddatacenterv2
神州数码 Jason pan future_clouddatacenterv2神州数码 Jason pan future_clouddatacenterv2
神州数码 Jason pan future_clouddatacenterv2
 
Synched E Harvesting Wireless Sensors For Sensors Expo 2009 Dist
Synched E Harvesting Wireless Sensors For Sensors Expo 2009 DistSynched E Harvesting Wireless Sensors For Sensors Expo 2009 Dist
Synched E Harvesting Wireless Sensors For Sensors Expo 2009 Dist
 
Microgrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & powerMicrogrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & power
 
Proactive and reactive thermal optimization techniques to improve energy effi...
Proactive and reactive thermal optimization techniques to improve energy effi...Proactive and reactive thermal optimization techniques to improve energy effi...
Proactive and reactive thermal optimization techniques to improve energy effi...
 
Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...
Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...
Alstom Grid And Capgemini Form Global Alliance For Smart Grid: About the Firs...
 
National lighting solutions
National lighting solutionsNational lighting solutions
National lighting solutions
 

Destaque

Why the Hastings Quinte Cultural Plan matters - 2014
Why the Hastings Quinte Cultural Plan matters - 2014Why the Hastings Quinte Cultural Plan matters - 2014
Why the Hastings Quinte Cultural Plan matters - 2014Hastings County
 
Final2
Final2Final2
Final2amhart
 
Credentials Comunicacion Iberoamericana
Credentials Comunicacion IberoamericanaCredentials Comunicacion Iberoamericana
Credentials Comunicacion IberoamericanaDiego barcel?
 
Why do we say that Zhou Qifeng is a Zhongshan wolf in sheep's clothing?
Why do we say that Zhou Qifeng is a  Zhongshan wolf in sheep's clothing?Why do we say that Zhou Qifeng is a  Zhongshan wolf in sheep's clothing?
Why do we say that Zhou Qifeng is a Zhongshan wolf in sheep's clothing?Dian Mo
 
Funcionamiento intelectual limite. fundación aequitas
Funcionamiento intelectual limite. fundación aequitasFuncionamiento intelectual limite. fundación aequitas
Funcionamiento intelectual limite. fundación aequitasMarta Montoro
 
Indicaciones de ORTO-K en consulta pediátrica
Indicaciones de ORTO-K en consulta pediátricaIndicaciones de ORTO-K en consulta pediátrica
Indicaciones de ORTO-K en consulta pediátricaCLINICA REMENTERIA
 
Taj renewable energy conference brochure
Taj renewable energy conference brochureTaj renewable energy conference brochure
Taj renewable energy conference brochurePrashant Rao
 
Baleno il wifi che costa meno!
Baleno il wifi che costa meno!Baleno il wifi che costa meno!
Baleno il wifi che costa meno!TLCWEB
 
P A C Swim Academy Brochure
P A C  Swim  Academy BrochureP A C  Swim  Academy Brochure
P A C Swim Academy BrochureMichael Swirsky
 
Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...
Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...
Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...BrittThom
 
Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...
Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...
Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...Miguel A. C. Sánchez
 
Los doce apóstoles de jesús_Sergio Pinto
Los doce apóstoles de jesús_Sergio PintoLos doce apóstoles de jesús_Sergio Pinto
Los doce apóstoles de jesús_Sergio Pintoreligion sjc
 
Real Estate Agents for mumbai
Real Estate Agents for mumbaiReal Estate Agents for mumbai
Real Estate Agents for mumbaiRitu Patil
 

Destaque (20)

Why the Hastings Quinte Cultural Plan matters - 2014
Why the Hastings Quinte Cultural Plan matters - 2014Why the Hastings Quinte Cultural Plan matters - 2014
Why the Hastings Quinte Cultural Plan matters - 2014
 
Final2
Final2Final2
Final2
 
The Law of Branding
The Law of BrandingThe Law of Branding
The Law of Branding
 
Credentials Comunicacion Iberoamericana
Credentials Comunicacion IberoamericanaCredentials Comunicacion Iberoamericana
Credentials Comunicacion Iberoamericana
 
Why do we say that Zhou Qifeng is a Zhongshan wolf in sheep's clothing?
Why do we say that Zhou Qifeng is a  Zhongshan wolf in sheep's clothing?Why do we say that Zhou Qifeng is a  Zhongshan wolf in sheep's clothing?
Why do we say that Zhou Qifeng is a Zhongshan wolf in sheep's clothing?
 
Funcionamiento intelectual limite. fundación aequitas
Funcionamiento intelectual limite. fundación aequitasFuncionamiento intelectual limite. fundación aequitas
Funcionamiento intelectual limite. fundación aequitas
 
Indicaciones de ORTO-K en consulta pediátrica
Indicaciones de ORTO-K en consulta pediátricaIndicaciones de ORTO-K en consulta pediátrica
Indicaciones de ORTO-K en consulta pediátrica
 
Taj renewable energy conference brochure
Taj renewable energy conference brochureTaj renewable energy conference brochure
Taj renewable energy conference brochure
 
Baleno il wifi che costa meno!
Baleno il wifi che costa meno!Baleno il wifi che costa meno!
Baleno il wifi che costa meno!
 
P A C Swim Academy Brochure
P A C  Swim  Academy BrochureP A C  Swim  Academy Brochure
P A C Swim Academy Brochure
 
Linkin park
Linkin parkLinkin park
Linkin park
 
Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...
Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...
Hashtags vs. Hard Copy Resumes: Guerrilla Job Search tactics for College Stud...
 
Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...
Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...
Comunicado sobre Inconstitucionalidad Sobre de la Ley del Impuesto Sobre la R...
 
Clients Speak on Client Protection- Findings from ASKI- the Philippines
Clients Speak on Client Protection- Findings from ASKI- the PhilippinesClients Speak on Client Protection- Findings from ASKI- the Philippines
Clients Speak on Client Protection- Findings from ASKI- the Philippines
 
Mang mt
Mang mtMang mt
Mang mt
 
Actividades h
Actividades hActividades h
Actividades h
 
Los doce apóstoles de jesús_Sergio Pinto
Los doce apóstoles de jesús_Sergio PintoLos doce apóstoles de jesús_Sergio Pinto
Los doce apóstoles de jesús_Sergio Pinto
 
Drogadiccion
DrogadiccionDrogadiccion
Drogadiccion
 
Real Estate Agents for mumbai
Real Estate Agents for mumbaiReal Estate Agents for mumbai
Real Estate Agents for mumbai
 
ROBBY KALRA
ROBBY KALRAROBBY KALRA
ROBBY KALRA
 

Semelhante a Nexus brosur (2)

Metering and Energy Functions - Slides
Metering and Energy Functions - SlidesMetering and Energy Functions - Slides
Metering and Energy Functions - SlidesIvory Egg
 
Powerqualitysolutions
PowerqualitysolutionsPowerqualitysolutions
PowerqualitysolutionsPOWERON1
 
Ldex Data Sheet 2 D Caa S V3
Ldex Data Sheet 2 D Caa S V3Ldex Data Sheet 2 D Caa S V3
Ldex Data Sheet 2 D Caa S V3mattedgley
 
Lifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor SystemLifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor SystemPowercast Sensors
 
World Meter Design Presentation: Opportunities in creating an effective meter...
World Meter Design Presentation: Opportunities in creating an effective meter...World Meter Design Presentation: Opportunities in creating an effective meter...
World Meter Design Presentation: Opportunities in creating an effective meter...guest36a0a6
 
Wireless sensor networks
Wireless sensor networksWireless sensor networks
Wireless sensor networksManoj BN
 
Professional Profile
Professional ProfileProfessional Profile
Professional Profilessramz
 
Lesto smart grid presentation
Lesto smart grid presentationLesto smart grid presentation
Lesto smart grid presentationEdward Zevelev
 
CA Nimsoft ecoMeter
CA Nimsoft ecoMeterCA Nimsoft ecoMeter
CA Nimsoft ecoMeterCA Nimsoft
 
Low-power Innovative techniques for Wearable Computing
Low-power Innovative techniques for Wearable ComputingLow-power Innovative techniques for Wearable Computing
Low-power Innovative techniques for Wearable ComputingOmar Elshal
 
Slideshare presentation
Slideshare presentationSlideshare presentation
Slideshare presentationNextronex Inc
 
Data acquisition system
Data acquisition systemData acquisition system
Data acquisition systemAkash Atul
 

Semelhante a Nexus brosur (2) (20)

Intelligent Line Monitoring System
Intelligent Line Monitoring SystemIntelligent Line Monitoring System
Intelligent Line Monitoring System
 
Multilin™ Intelligent Line Monitoring System
Multilin™ Intelligent Line Monitoring SystemMultilin™ Intelligent Line Monitoring System
Multilin™ Intelligent Line Monitoring System
 
Metering and Energy Functions - Slides
Metering and Energy Functions - SlidesMetering and Energy Functions - Slides
Metering and Energy Functions - Slides
 
Powerqualitysolutions
PowerqualitysolutionsPowerqualitysolutions
Powerqualitysolutions
 
Ldex Data Sheet 2 D Caa S V3
Ldex Data Sheet 2 D Caa S V3Ldex Data Sheet 2 D Caa S V3
Ldex Data Sheet 2 D Caa S V3
 
Lifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor SystemLifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor System
 
Metering Solutions
Metering SolutionsMetering Solutions
Metering Solutions
 
Aurora Australis UK
Aurora Australis UKAurora Australis UK
Aurora Australis UK
 
NortQ 921021 brochure
NortQ 921021 brochureNortQ 921021 brochure
NortQ 921021 brochure
 
Smart grid aep_ge
Smart grid aep_geSmart grid aep_ge
Smart grid aep_ge
 
World Meter Design Presentation: Opportunities in creating an effective meter...
World Meter Design Presentation: Opportunities in creating an effective meter...World Meter Design Presentation: Opportunities in creating an effective meter...
World Meter Design Presentation: Opportunities in creating an effective meter...
 
Wireless sensor networks
Wireless sensor networksWireless sensor networks
Wireless sensor networks
 
Professional Profile
Professional ProfileProfessional Profile
Professional Profile
 
Lesto smart grid presentation
Lesto smart grid presentationLesto smart grid presentation
Lesto smart grid presentation
 
Conzerv schneider
Conzerv schneiderConzerv schneider
Conzerv schneider
 
CA Nimsoft ecoMeter
CA Nimsoft ecoMeterCA Nimsoft ecoMeter
CA Nimsoft ecoMeter
 
Convertrule
ConvertruleConvertrule
Convertrule
 
Low-power Innovative techniques for Wearable Computing
Low-power Innovative techniques for Wearable ComputingLow-power Innovative techniques for Wearable Computing
Low-power Innovative techniques for Wearable Computing
 
Slideshare presentation
Slideshare presentationSlideshare presentation
Slideshare presentation
 
Data acquisition system
Data acquisition systemData acquisition system
Data acquisition system
 

Último

AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfAMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfphamnguyenenglishnb
 
Proudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptxProudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptxthorishapillay1
 
ENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choomENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choomnelietumpap1
 
USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...
USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...
USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...Postal Advocate Inc.
 
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTSGRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTSJoshuaGantuangco2
 
Global Lehigh Strategic Initiatives (without descriptions)
Global Lehigh Strategic Initiatives (without descriptions)Global Lehigh Strategic Initiatives (without descriptions)
Global Lehigh Strategic Initiatives (without descriptions)cama23
 
Like-prefer-love -hate+verb+ing & silent letters & citizenship text.pdf
Like-prefer-love -hate+verb+ing & silent letters & citizenship text.pdfLike-prefer-love -hate+verb+ing & silent letters & citizenship text.pdf
Like-prefer-love -hate+verb+ing & silent letters & citizenship text.pdfMr Bounab Samir
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Mark Reed
 
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...JhezDiaz1
 
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...Nguyen Thanh Tu Collection
 
What is Model Inheritance in Odoo 17 ERP
What is Model Inheritance in Odoo 17 ERPWhat is Model Inheritance in Odoo 17 ERP
What is Model Inheritance in Odoo 17 ERPCeline George
 
Student Profile Sample - We help schools to connect the data they have, with ...
Student Profile Sample - We help schools to connect the data they have, with ...Student Profile Sample - We help schools to connect the data they have, with ...
Student Profile Sample - We help schools to connect the data they have, with ...Seán Kennedy
 
Earth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice greatEarth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice greatYousafMalik24
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxiammrhaywood
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designMIPLM
 
Choosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for ParentsChoosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for Parentsnavabharathschool99
 

Último (20)

AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfAMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
 
Proudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptxProudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptx
 
ENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choomENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choom
 
USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...
USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...
USPS® Forced Meter Migration - How to Know if Your Postage Meter Will Soon be...
 
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTSGRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
GRADE 4 - SUMMATIVE TEST QUARTER 4 ALL SUBJECTS
 
Global Lehigh Strategic Initiatives (without descriptions)
Global Lehigh Strategic Initiatives (without descriptions)Global Lehigh Strategic Initiatives (without descriptions)
Global Lehigh Strategic Initiatives (without descriptions)
 
Like-prefer-love -hate+verb+ing & silent letters & citizenship text.pdf
Like-prefer-love -hate+verb+ing & silent letters & citizenship text.pdfLike-prefer-love -hate+verb+ing & silent letters & citizenship text.pdf
Like-prefer-love -hate+verb+ing & silent letters & citizenship text.pdf
 
YOUVE_GOT_EMAIL_PRELIMS_EL_DORADO_2024.pptx
YOUVE_GOT_EMAIL_PRELIMS_EL_DORADO_2024.pptxYOUVE_GOT_EMAIL_PRELIMS_EL_DORADO_2024.pptx
YOUVE_GOT_EMAIL_PRELIMS_EL_DORADO_2024.pptx
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)
 
YOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptx
YOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptxYOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptx
YOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptx
 
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
 
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptxFINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
 
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
 
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
 
What is Model Inheritance in Odoo 17 ERP
What is Model Inheritance in Odoo 17 ERPWhat is Model Inheritance in Odoo 17 ERP
What is Model Inheritance in Odoo 17 ERP
 
Student Profile Sample - We help schools to connect the data they have, with ...
Student Profile Sample - We help schools to connect the data they have, with ...Student Profile Sample - We help schools to connect the data they have, with ...
Student Profile Sample - We help schools to connect the data they have, with ...
 
Earth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice greatEarth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice great
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-design
 
Choosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for ParentsChoosing the Right CBSE School A Comprehensive Guide for Parents
Choosing the Right CBSE School A Comprehensive Guide for Parents
 

Nexus brosur (2)

  • 1. Nexus 1262/1272 ® Accu-Measure™ High Performance Utility Billing Meters Auto-Calibrating Metrology With Communication & Advanced Power Quality Nexus® 1272 Performance Meter with Advanced Power Quality & Communication Nexus® 1262 Economical Meter with Advanced Communication • 0.06% Watt/Hr Revenue Meter www.electroind.com • Auto-Calibrating Metrology • Multi-Point CT & PT and Loss Compensation New! Total Web Solutions • Advanced Power Quality Recording WebExplorer WebReacher WebXML WebAlarm WebMod WebDNP • Eight Totalizing Registers XML Web Server • Data Logging & Event Recording Email on Alarms DNP 3.0 over Ethernet • Unique Powerful Display Configurator • Multiple Communication Paths For Smart Grid and Intelligent • Combination Modem & Ethernet Substation Applications Electro Industries/GaugeTech MV90 The Leader in Power Monitoring and Smart Grid Solutions Compatible
  • 2. Accu-Measure Auto-Calibrating Metrology The Nexus® 1262/1272 meters are designed for demanding smart grid and intelligent substation applications. They provide one of the most profound analyses of electricity available in a socket meter. The units offer extensive advanced monitoring features to meet the most critical power monitoring requirements. Using advanced DSP technology, the Nexus®’ measure immediate and stored revenue power data coupled with superior power quality and communication. To meet the sophisticated standards required by utility companies and de-regulated power providers, the Nexus®’ basic package starts where most other meters end. Standard features in Nexus® units provide the ability to meet advanced metering needs for the future. Accu-Measure™ Auto-calibrating metrology Load Aggregation/Universal Metering EIG’s Accu-Measure™ Auto-Calibrating Metrology provides unmatched Using standard pulse ® accuracy. inputs, the Nexus 1262/1272 • Energy and Power Accuracy to Within 0.06% can count pulses from external • Auto-calibration over Time meters and accumulate usage. • Automatic Temperature The pulse inputs can be used Drift Adjustments to totalize electrical usage and utility values, such as water or 4 Quadrant gas use data. measurement • 8 Pulse Inputs The unit is a full four quad- • Individual Accumulating Registers rant meter and gathers hour data • 4 Totalizing Registers (Add or Subtract) information in every quadrant. • kWh Delivered and CT & PT Compensation Received The Nexus® units compensate for errors in current transformers and • kVAh in Each Quadrant potential transformers. • kVARh in Each Quadrant • Voltage Compensation • Q Hours • Multipoint Current Compensation Time of Use • Multipoint Phase Angle The 1262/1272 offers Compensation robust time of use functionality. • Better than 0.01% Standard capabilities include: Resolution • 8 TOU Schedules • 4 Seasons/Year Multiple Demand Windows • 20 Year Calendar The Nexus® 1262/1272 simultaneously monitors five demand structures. • Prior Month and Prior Season • lock Window Demand B • Interval Length from 1 Second • rogrammable Freeze Registers P • Rolling Window Demand to Many Hours • Predictive Demand • End of Interval Pulse Output Transformer • Thermal Demand • End of Interval Pulse Input or Line Loss • Cumulative Demand • Cold Load Pickup Compensation Loss Compensation adjusts Time Stamped Max. Demands for both copper and iron losses The units gather demand information for all power values. Each value is with a simple user setup. date/time stamped. • kW Demand, Delivered • kVAR Coincident with kW Demand Field Test Mode Received, Max/Min • kVA Demand, Max/Min • Test All Energy Readings • kVAR Demand, Delivered • Amps Demand, Max/Min • Enable/Disable in Received, Max/Min • Voltage, Max/Min Test Mode • Preset Accumulators • Freezable Accumulators 2 Reliable, Functional and Feature-Rich Metering
  • 3. Configure Custom Display For Any Application Unique Display Configurator The Nexus® 1262/1272 is designed with one of the industry’s most advanced LCD display configuration technologies. With this highly customizable display, choose from multitudes of pre-programmed display screens and create fully customized displays for any specific application. Build, from scratch, user display screens as needed that provide information on anything the meter measures (which is almost everything). Use the display to view not only electrical, but water or gas usage. Also use the meter as an aggregator for total usage. Provide ambient and transformer temperature or any other desired critical operational data on the display. Custom display configurator to Create Exactly What’s Needed • Make Custom Screens Based on Modbus Registers 01 kWh Delivered • Make Any Custom Labels 00001.66 • Customize Screen Numbering and Order • Display Up To 5 Pieces of Information Per Screen 08/03/10 16:46:45 1 C • Display Water, Gas and Other Types of Usage • Add Diagnostic Information Normal Mode • Wh Delivered and Received k • kVARh Delivered and Received • kVAh Delivered and Received • Peak Rolling Window Demands • Peak Block Window Demand 3 Display Modes/75 Screen Slots Time of Use Mode The meter’s memory has 75 slots for custom and/or pre-programmed • kWh and kW Demand Delivered and Received Total screens. These slots can be allocated to any view mode with any number of • VARh and kVAR Demand Delivered and Received for Each Register k slots used in each of the modes. • VAh Delivered and Received for Each Register k • kVAh Delivered and Received Total Pre-configured Diagnostic Screens Select from a large offering of diagnostic screens such as: • Voltages • Phase Angles • Harmonic Magnitudes • Firmware Versions • Meter Status • Phasor Diagram • er Phase Amps P • Watts/VARs • Many More Diagnostic Screens Available Infrared Test Pulse The meter provides an infrared test pulse that can pulse for +Watt-Hour, -Watt-Hour, +VAR-Hour, -VAR-Hour and VA-Hour. This pulse uses a time modu- lated pulse integration, allowing the pulse to be accurate during short duration Highly configurable display assignments pulse tests using industry accepted reference standards. 3
  • 4. Advanced Communications and I/O Capabilities Standard multi-port Control Capabilities Total Web Solutions— Communications • ElectroLogic™ Provides User-definable Providing Advanced • Optical Port Control Outputs Metering Data Integration • RS485 Serial Ports 2 • Action and/or Alarm on Abnormal Condition With the Web • Modbus RTU/ASCII • Action on Boolean Logic Combinations of Total Web Solutions is an advanced • DNP 3.0 Inputs or Electrical Conditions Ethernet communication architecture that • Speeds Up to 115k bps lets you design custom webpages, display DNP 3.0 Level 2 Plus metering data and host your meter power Optional Communications The Nexus® 1262/1272 provides the industry’s information website directly on a Nexus® • Dial-Out modem (56k) with Battery most advanced DNP 3.0 protocol implementations. meter. The Nexus® meter directly hosts the Backed Outage Reporting DNP 3.0 is available on the serial and Ethernet ports. web data without any need for dedicated ® • 10/100BastT Ethernet EIG’s Nexus 1262/1272 complies with all DNP server software, ActiveX Controls or Java • Ethernet/Modem combo Level 1 and Level 2 certification requirements PLUS Applets. The meter does the data collection, a host of additional features including: the formatting and the page hosting. Combination Modem • Up to 136 Measurements: Web Solution 64 Binary Inputs, 8 Binary Counters, Advanced Features Include: This option allows you to access the meter 64 Analog Inputs Mapped to DNP Static Points • Fully Customizable Webpage Development through the web and through a modem for dial-up in the Customizable DNP Point Map • Direct Webpage Hosting With Live Readings communication. Features include: • Up to 16 Relays and 8 Resets: Can Be • Multiple Meter Hosting • 56k Modem Controlled through DNP • Read Direct From Meters (No Server • 10/100BastT Ethernet • Report-By-Exception Processing: (DNP Software Needed) • Total Web Solutions (Web Server) Events) Deadbands Can Be Set on a • No Active Controls or Java Downloads • Email on Alarm Per-point Basis • IT Dept Friendly. Works Through Firewalls; • Does Not Support Battery for • 250 Events in Combinations of Four Events: Low-Cost/High Functionality Outage Reporting Binary Input Change, Frozen Counter, • Instant Alarm Emails – Direct from the Meter Counter Change, Analog Change Standard I/O • Freeze Commands: Freeze, Freeze/No-Ack, WebExplorer • IRIG-B 1 msec Time Synchronization to Freeze with Time, Freeze with Time/No-Ack, (Directly Host Metering Data) GPS Satellite Clock scheduled Freeze Command EIG’s WebExplorer provides you with direct • 4 Internal KYZ Pulse Outputs • Freeze with Time Command: access to all power data through Internet Explorer • 8 KYZ Pulse/Status Inputs Enables the Nexus® Meter to Have Internal in standard HTML format, without needing to down- Time-driven Frozen Counter and Frozen load ActiveX controls or Java applets. WebExplorer Optional External I/O Counter Event data is fully programmable, so you can customize Connect multiple external I/O Modules for • Third Party Certification is Available your own SCADA quality webpages, graphics and enhanced I/O capability. configurations. • Analog Outputs • Easily Incorporated Into Any Existing Web • Analog Inputs Applications • Digital Status Inputs • Fully Programmable Webpage Generator • KYZ Outputs • Brings in Direct XML Links, Displaying Many • Relay/Alarm Outputs Meters on One Page WebXML Creates Real Time Data in XML Format. WebXML allows the Nexus® meter to gather data from the Nexus® Host or through other meters and put the data directly into an XML format. This allows you to share data through the web with multiple applications and create custom webpages, using WebExplorer. 4 WebExplorer WebXML WebReacher
  • 5. Total Web Solutions WebAlarm – Email Alerts features are available simultaneously. Even with DNP EIG’s WebAlarm sends real time email alerts via 3.0 over the Ethernet, you still have access to multiple the Internet to up to 9 recipients simultaneously for Modbus sockets, email alarms, web servers and any combination of event notifications. many other communication features. Webmod (Open Architecture 3rd Party Integration) WebXML technology is easy to configure and extremely flexible. With WebXML, your data is instantly available to a host of software applications including Internet Explorer, Excel, Power Point and Word. • Real Time Alerts • Automatically Process and Present Data In • Simultaneous Emails to Multiple Recipients Readable XML Format • Update Users on Virtually Any Abnormality • Add Scale Factors, Multipliers or Other • Uses Standard SMTP — Just Assign Email Desired html Capability Addresses • Display Data From Host Meter and/or Any • Shows the Last 10 Emails on Website for The 10/100BaseT design allows the unit to Other Meter Using Modbus RTU or TCP/IP Later Investigation speak with 12 simultaneous sockets of Modbus TCP. (WebReacher) EIG’s WebMod features Modbus TCP open protocol • Customized Programming Webdnp that can be easily integrated with most other software • Easily Viewed By Different Applications Using this feature, you can gain access to the or hardware. And, with the built-in Modbus data con- • Modbus Data Concentrator meter speaking native DNP over Ethernet. This allows centrator, you can poll up to 8 devices or 512 unique the unit to open an exclusive network socket for DNP polling items from any device that can speak Modbus WebReacher 3.0. Using this unique technology, all other meter web RTU and/or Modbus TCP protocols. With EIG’s exclusive WebReacher technology, you can now access remote meters around the View data from multiple meters generated from the Master Meter in your web browser. WebXML provides Meter 124 totalized energy usage Internet Explorer WebMod TCP/IP Web M od T CP/I P P/IP We TC od world, retrieve data and consolidate it onto one Meter 115 bM M eb /IP W od webpage or website without any separate software P TC TC SCADA package or client-side ActiveX controls or d P Mo /IP Java applets. b We • No Additional Software Application Costs Meter 31 • No Server System Required • No Complex Integration • No Costly Point Charges (Up to 32 Devices) Web Solutions allows a meter Meter 87 to display data from many Meter 14 remote meters. 5 WebAlarm WebMod WebDNP
  • 6. Nexus® 1272 Advanced Power Quality Analysis Pinpoints Electrical Reliability Issues The processing capability and accuracy of the Nexus® 1272 makes it possible to gather power quality information with unmatched precision. The Nexus® 1272 is ideally suited for application on all critical loads. From health care to micro-electronics, the 1272 has what it takes to capture every anomaly. This insures that when there is a power problem, you have the information required to act. All Power Quality logs are time stamped to the nearest millisecond to insure accurate recording. Nexus®’ Advanced Download Logic collects only new data to minimize download times. Event/Out of Limit Log • Records 1024 Events • Extensive Limit Setting Capabilities • Out of Limit Recording with Multiple Limits per Selected • High-Speed Input Event Recording Quantity • Outage Detection Waveform Log The waveform recording capability of the Nexus® is unparalleled by any meter. Waveform records of this quality have historically been reserved only for transmission lines. The power of the Nexus® 1272 now makes this quality available to your critical customers. • xtraordinary Resolution through E • Up to Six Channels 16 bit A/D Input • Voltage and Current Triggers • Sample Rates from 16 to 512 • E xternal Event Trigger Samples per Cycle • Voltage Surge/Sag Recording • Total Recording Times over 100 • Current Fault Analysis Seconds Harmonic Distortion Analysis CBEMA/ITIC Log • Log Harmonics into Historical Log for Later Analysis The separate CBEMA/ITIC Log captures all voltage transients • Recorded Waveforms Provide Harmonics to the 255th Order that fall outside these standards. The onboard log holds 1024 events. • View Waveform Record The data is downloaded to a separate log in the meter database for easy analysis. See all voltage disturbances on one screen through the Communicator EXT software. • Sag/Swell Analysis • Transient Recording 6
  • 7. Advanced Reporting and Analysis System Performance and Reliability Analysis The accuracy and precision of the Nexus® 1272 coupled with its extraordinary logging capability makes it an ideal tool for system performance and reliability analysis. For the first time, users have the accuracy and precision of a digital fault recorder at the revenue- metering site without the expense. The Nexus®’ 16-bit accuracy and resolution for waveform records actually exceeds many digital fault recorder products. Combine the Nexus® 1272 with EIG’s suite of software solutions to further expand the level of understanding during any monitoring situation. AiReports – Communicator EXT PQ Analysis Fault Analysis AiReports provides automated • Compares Multiple Fault analysis and reports (1272 Only) for Records abnormal events. • Measures Waveform Traces • Uses Artificial Intelligence • Inserts Timing Marks to • Evaluates All Data from Analyze Waveform Transients ® Nexus Monitor • Views CBEMA Logs Download the data and open the At The Customer • Rates Events for Severity files with Communicator EXT. Compare When that key customer calls, • Identifies Probable Causes At The Interchange multiple channels. Measure amplitudes simply perform a download from the • Identifies Possible Impacts Point and timing with millisecond resolution. Nexus® 1272. In a few minutes, all the • Recommends Corrective Nexus® gives you the power See system reliability events that lasted data related to any event is on your Actions or Solutions of a sequence of events recorder on for several seconds. desktop. A completed report is ready • Prepares and Formats Report every transmission line or interchange to review internally or email to the cus- of All Power Quality Events point. Nexus® is always watching Test Protective tomer. Probable causes are identified • PQDIF File Format Converter and has extended memory capability, Equipment and corrective actions recommended. Allows Nexus® Data to be which can record multiple faults, or Need to test protective equip- Need to perform a more detailed Read by Standard EPRI Power even frequency swings, during stabil- ment performance? Simply take evaluation? Simply open the viewer to Quality Viewing Software. ity problems. Capture all voltages and the Nexus® record and convert to look at the waveforms and see exactly • COMTRADE File Converter currents. COMTRADE format. Insert the file what happened to voltages and Changes Fault Records to directly to protective test equipment currents throughout the event. Only Standard Fault Analysis File to verify relay performance. Nexus® provides precise pictures for Formats many seconds. Supported Meter Forms Accuracy FORM RATED VOLTAGE HOOKUP PARAMETER ACCURACY 9S 0 to 277V 3E, 4W, Wye Voltage 0.02% L-N Current 0.05% 36S 0 to 277V 2½ E, 4W, Wye Frequency 0.001Hz L-N with Neutral kW 0.06% 45S 0 to 480V 2E, 3W, Delta L-L kWh@1.0PF 0.06% WB2 S 0 to 277V Programmable kWh@0.5PF 0.10% (Universal Forms) kVAR 0.10% 9A 0 to 277 A Base Form kVA 0.10% L-N PF 0.10% 7
  • 8. Data and Event Monitoring/Recording Multiple Memory System Events Log Logs The unit records the following Nexus® meters provide many logs system events for security and anti- to record historical, alarm and system tampering. event data. These logs can be used for • Power Up profiling, recording events and logging • Power Down electrical power parameters over time. • Password Access Additionally, using the advanced I/O • Password Modification available with the product, you can also • Change of Programmable Settings log process measurements, including • Change of a Run Time temperature, pressure, flow, etc. • hange of Clock Time by C Communication (Modbus Two Historical or DNP) Historical Trending Trend Logs • Test Mode Usage These logs allow you to trend • Meter Resets (Logs, Max/Min, virtually any electrical parameter over Energy) time. This includes all electrical and I/O parameters. Input Status Log • p To 64 Values per Log U This log records when a digital • Programmable Trend Times status change occurred in either the Replace Conventional Chart Recorders • Provides Magnitude and internal or external inputs. Duration of Event • Status Log for External Events • Millisecond Resolution • I nternally Labeled to Define • 2 Separately Programmable Logs Events • Separately Recorded Time Base • Records Alarms For Electrical Control Output Log and I/O Channels This log records the logic and state that triggered a control output. Out of Limits Log The graphical log shows all the steps This log records all out-of-limit that led up to the event. alarms, including the magnitude and • Displays Pre- and Post- the duration of the alarm. Analysis • nternally Labeled to Define I Events • dvanced I/O Analysis A View Alarms, Status Changes and Control Events Logging Specifications Model Memory Historical Historical CBEMA / Out of Limit Waveform Output Log 2 Input System Log 11 Log 2 1 ITIC 2 Log 2 Log 3 Log 2 Events 2 1272 Standard 85 Days 133 Days 512 1024 63 256 1024 1024 1272 Advanced 555 Days 133 Days 512 1024 95 256 1024 1024 1262 Standard 69 Days 32 Days N/A 512 N/A 512 1024 1024 1262 Advanced 480 Days 133 Days N/A 512 N/A 512 1024 1024 1 Assumes Logs store 4 scaled energy readings every 15 minutes 3 Number of Waveform Records. Each record may be from 8 to 64 cycles in duration depending upon meter setup 2 Number of Events Recorded (assumes 14 parameters monitored) 8
  • 9. Dial-Out On Alarm (INP2) Dial-Out on Outage The INP2 modem has a dial-out circuit with a battery that detects when Event voltage is lost and dials out to provide outage notification. Additionally, the circuit Meter can be configured to dial out when many other circumstances occur. The Nexus® Dials Out on Event 1262/1272 dials to the EIG Dial-In Server which allows users to be paged or emailed with notification of events. When the modem option card is installed, the meter also includes a gateway port. This allows the meter to act as a master for up to 7 additional meters and dial out on alarm for any of these meters. RS485 Connection Dial-Out for Other Events The meter will dial out for the following circumstances: Telephone • Limits/Status Change • Control Output Change Dial-out Modem • High Speed Input Change • Cycling of Control Power INP2 • Waveform Record Capture • Password Failure on a Call Server Receives • CBEMA Power Quality Event Coming into the Modem Alarm • Control Output Change • Meter Communication Failure Server Provides: • Alarm Notification • ogging L Download Modem Call In Event • Automated Alerts Visual Alarm Dial-In Server Capabilities The EIG Dial-In Server will record all notifications, accept downloads from the Automatic Notification Via Pager, Cell Phone or Email meter and allows users to be notified by email and paging automatically. Features of the Dial-In Server include: • Unlimited Meters • Scalable Multi-server Architecture • Email Notification • Paging Notification • Audible System Alarm Dial-In Settings 9 Dial-Out Logic
  • 10. Dimensions and Mounting Nexus® 1262/1272 Nexus® 1262/1272 Switchboard Case Front View Switchboard Case Back View 6.13” (15.57 cm) Y K Z | Y CH2 Z | Y CH3 Z | Y CH4 Z | K K K S (1) (+) 8.5” CH1 Gateway (21.6 (-) (+) S (-) (+) | | S (-) (+) | 8 7 6 5 4 3 2 1 C cm) 4.38” 9.25 (234.95 mm) IRIG-B COM1 COM4 HIGH SPEED 9.25” (11.11 L N PE (23.5 cm) Power In Network Phone Line cm) 9.0” (22.9 cm) Vc Ia - Hi Ib - Hi Ic - Hi Va + + + + + Vn Lo Lo Lo Vb + + + + + 0.19” (.048 cm) 5.6” (14.22 cm) 6.85” (17.4 cm) 6.85 (173.99 mm) 6.58” (16.51 cm) Nexus® 1262/1272 Nexus® 1262/1272 Nexus® I/O Modules Front View Side View Front View 1.10” (2.8cm) 0.63” (1.60cm) 1.31” (3.33cm) 6.96” (17.68 cm) 2.20” 3.68” (9.35cm) (5.6cm) 6.16” (15.64cm) 6.00” (15.24cm) 3.40” (8.63cm) Nexus® 1262/1272 Nexus® 1262/1272 A Base A Base Front View Side View 0.87” (2.21cm) 4.23” (10.74cm) 10.17” (25.83cm) 2.00” (5.08cm) 7.00” (17.8cm) 6.18” (15.7cm) 10
  • 11. Specifications Wiring Diagrams FORM: 9S (TRANSFORMER RATED) SERVICE: WYE, 4WIRE 3 Switchboard Mount 3 PTs, 3 CTs N LINE 1 SERVICE: WYE, 4WIRE 8! 8 8 3 PTs, 3 CTs 2 3 Y K Z CH1 | Y CH2 Z | Y CH3 Z | Y CH4 Z | K K K S (1) (+) Gateway 1! (-) (+) S (-) (+) | | S (-) (+) | 8 7 6 5 4 3 2 1 C N IRIG-B COM1 COM4 HIGH SPEED 1 L N PE Power In Network Phone Line 1 2 Va 1 Vc Ia - Hi Ib - Hi Ic - Hi + + + + + Vn Lo Lo Lo Vb + + + + + LINE 8 ! 8 Hi 8! lc Lo Hi CTs lb Lo Hi la Lo PTs 8= 8 8? Form 9S 4-Wire Wye LOAD FORM: 45S (TRANSFORMER RATED) SERVICE: DELTA, 3WIRE 3 LOAD 2 PTs, 2 CTs LINE Switchboard Mount 8! 8 8 2 1 SERVICE: DELTA, 3WIRE 1! 2 PTs, 2 CTs 3 Y K Z CH1 | Y CH2 Z | Y CH3 Z | Y CH4 Z | K K K S (1) (+) Gateway 1 (-) (+) S (-) (+) S (-) (+) 8 7 6 5 4 3 2 1 C | IRIG-B COM1 | COM4 | HIGH SPEED L N PE Power In Network Phone Line 2 1 Vc Ia - Hi Ib - Hi Ic - Hi Va + + + + + Vn Lo Lo Lo Vb + + + + + 8 8! LINE ! Hi 8 lc Lo Hi CTs la Lo PTs 8= LOAD 8? Form 45S 3-Wire Delta LOAD 11
  • 12. Specifications SENSE INPUTS: (18 to 60)Vdc. Burden 9W max. • n Resistance: 23-35Ω O APPROVALS CURRENT (ac) • Separate power cord. • eak Voltage: 350V DC P • EC 60687 - KEMA Certified I • ransformer (CT) rated T • witchboard meter is always separately powered S • ontinuous Load Current: 120mA C • EC 62053-22 - KEMA Certified I • or 3 current inputs depending on Form 2 (option SE or DE). • eak Load Current: 350mA (10ms) P • alifornia ISO C (Ia, Ib, Ic) ISOLATION • ff State Leakage Current @350V DC: 1: µA O • Y State Public Service Commission N • Class 2 – 1A nominal, burden 0.000312VA@2.5A • ll Inputs and Outputs Isolated to 2500 Volts A • pto Isolation: 3750V rms (60Hz, 1 min.) O • SDA Technical Standards Committee Rural U • lass 10, 20 – 5A nominal, burden C • om Ports Isolated From Each Other to 1000 Volts C Development Unit CLOCK TIMING 0.0125VA@25A SENSING • Mi - Brazil N • nternal Clock Crystal - Accuracy Better than I • 0.1% of nominal pickup current • ccu-Measure™ Technology A • EEE - Brazil C 2 Minutes per Month • 120% over range of Meter Class • 6 bit A/D Inputs 1 • nion Fenosa - Spain U • IRIG-B Input for Synchronizing to External GPS • urrent surge withstand (at 23°C) - 100 Amps C • rue RMS T Clock Signal - Accuracy Better than 1 msec • AM - Endesa Chile C for 10 seconds, 300 Amps for 3 seconds, • Channel Sample Hold 8 per Month • lectric Power Test Research Institute of China - E 500 Amps for 1 second MEMORY • ine Sync - Accuracy Better than 1 Second L China Southern Power Grid VOLTAGE (ac) • ll Meter Setup Parameters, Measurements A per Month • hina Northwestern Electric Power Research C • Blade powered unit, standard voltage (option S): Logs Contained in Nonvolatile RAM ENVIRONMENTAL Institute 480Vmax Phase to reference (Va, Vb, Vc to Vref). STANDARD COMMUNICATIONS • perating Temperature: (-40 to +85)°C O • CEPRI - Beijing N Burden total 12VAmax (including power supply) • CD Display L • isplay Temperature: (-20 to +60)°C D • EPRI - China State Grid C 600Vmax Phase to Phase (Va to Vb, Vb to Vc, • R Port I Vc to Va) • aintight Lexan Cover (Socket) R • TS - Korea A • wo RS485 Serial Ports T • lade powered unit low voltage (option LV): B • Temperature Specifications to Indirect Light • odbus RTU, Modbus ASCII, DNP 3.0 M COMPLIANCE standards 69Vmax between Vref and Va, Vb, Vc inputs. SECURITY • ata Speeds of up to 115k bps D • NSI C12.20 A Accuracy Burden total 12VAmax (including power supply) • ardware Lock Secures Meter Settings H 120Vmax between Va, Vb, Vc inputs • ight High-Speed Input Channels E • NSI/IEEE C37.90.1 Surge Withstand A • wo 10-Character Passwords T • NSI C62.41 A Surge Immunity • xternally powered units (options SE, DE): E OPTIONAL COMMUNICATIONS • ne Password Controls Access to Read O 480Vmax between Vref and Va, Vb, Vc inputs. • EC 1000-4-2 I ESD • 6K Modem with Dial-Out Capabilities 5 Meter Digitally Burden 0.33VA@576V • EC 1000-4-3 I Radiated Immunity • nternal 10/100BaseT Rapid Response™Ethernet I • eparate Password Controls Access to S • EC 1000-4-4 I Fast Transient 600Vmax between Va, Vb, Vc inputs Program Meter • Input impedance 1Mohm/phase. • odem/Ethernet Combo Card M • EC 1000-4-5 I Surge Immunity • Modbus TCP and DNP LAN/WAN • dditional 8 level password sequence A • EC 1000-4-6 I Conducted Immunity • 20% over range of rated voltage. available by user configuration INTERNAL 8ch DIGITAL INPUTS • EC 60068-2-6 I Vibration (Sinusodial) • 2V pickup voltage. SHIPPING • EC 60068-2-27 Shock Test I EXTERNAL POWER SUPPLY • ype: Self Excited, for Dry Contacts Only T Weight: • EC 695-2-1 I Resistance to Heat Fire OPTIONS • nternal Wetting Voltage: 12V DC Typical I • EC 68-2-1 I Cold Test • tandard external (option SE): S Socket: 10 Lbs Switchboard: 16 Lbs INTERNAL 4ch • EC 68-2-2 I Dry Heat (102 to 276)Vac @50/60Hz. 12VA max. SOLID STATE OUTPUTS (kyz) Dimensions: • EC 68-2-30 I Damp Heat • ow voltage external (option DE): L • ype: Form A or C T Socket: 13 x 10 x 11 Switchboard: 16 x 14 x 11 Ordering Information (To order, please use this guide) Model Memory Form Class (Amps) Frequency Power Supply1 Optional Communication Option Numbers: − − − − − − Example: 1272 − A − 45S − 20 − 50 − DE − INP200 1272 S 9S 2 50 S X Std Amps 50 Hz Std Blade Powered No Optional Com 1262 A 36S 10 60 SE INP2 Adv Amps 60 Hz Std Ext Modem 102-270V AC/DC with Dial-Out 45S 20 DE INP200 Amps DC Ext 10/100BaseT Ethernet 18-60VDC SWB2 LV INP202 (Switchboard) 69VAC Modem Blade Powered Ethernet Combo (No Dial-Out) 9A (A Base) 1 Switchboard Meter Only Supports SE or DE Options. Accessory Options O PTIO N A L I / O M OD UL E S POWE R OP TI O NS S O F TWARE O P TI O NS 1mAON4 4 Analog Outputs, 0-1mA PSIO I/O Power Supply (Required COMEXT3.1C ommunicator EXT 3.0 for Windows © C 1mAON8 8 Analog Outputs, 0-1mA with I/O Module) Single-Computer License (One Site) 20mAON4 4 Analog Outputs, 4-20mA BAT1 External Replaceable Battery for COMEXT3.MC ommunicator EXT 3.0 for Windows © C 20mAON8 8 Analog Outputs, 4-20mA Dial Out on Outage Multiple-Computer License (One Site) 4RO1 4 Relay Outputs AIEXT.1C A iReports EXT Power Analysis Software 4PO1 4 Solid State Pulse Outputs for Windows © Single-Computer License M OU N T ING O P TI O NS (One Site) 8AI1 +/- 0-1mA, 8 Analog Inputs 8AI2 +/- 0-20mA, 8 Analog Inputs MBIO I/O Module Mounting Bracket AIEXT.MC Multiple-Computer License (One Site) Power Supply and Mounting Bracket 8AI3 +/- 0-5VDC, 8 Analog Inputs DISEXT.1C D ial-In Server Single-Computer License Required with any I/O Option 8AI4 +/- 0-10VDC, 8 Analog Inputs (One Site) 8DI1 8 Status Inputs, Wet/Dry DISEXT.MC Dial-In Server Multi-Computer License (One Site) Electro Industries/GaugeTech 1800 Shames Drive • Westbury, NY 11590 1- 877- EIMETER (1- 877- 346- 3837) • E-Mail: sales@electroind.com Tel: 516-334 -0870 • Web Site: www.electroind.com • Fax: 516-338-4741 E151702 081811 Rev J