1. HC LR-01
RESIDENTIAL CUT-AWAY WALL SECTION
Tradical® Hemcrete® Wall System:
Internal Wood Frame with Lime Render Exterior
Vapor Permeable Paint (2 Coats)
Vapor Permeable Magnesium Board
Tape and Mud at Magnesium Board Joint
Magnesium Board Fastener
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable thickness to
suit required thermal performance)
5/8” Baumit FL68 Lime Render Base Coat
1/8” Pre-colored Baumit SEP02 Lime
Render Top Coat
Flashing
Metal Stop Bead at Bottom Edge of Lime
Render
Brick Veneer at Exposed Foundation
Insulative R-Value* 35.5
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 13”
Embodied Carbon Dioxide Output -4.1
in kilograms per square foot
Recyclable or Biodegradable Content 95%
Approximate Cost Per Square Foot $29
Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wall
While reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,
included in this drawing was accurate at the time of issue, American opening or mechanical conditions.
Lime Technology reserves the right to change specifications at any
time. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.
site and client specific requirements.
website: http://www.americanlimetec.com
LAST REVISED 2010-11-16 email: info@americanlimetec.com
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
2. HC LR-02
RESIDENTIAL CUT-AWAY WALL SECTION
Tradical® Hemcrete® Wall System:
Central Wood Frame with Lime Render Exterior
Vapor Permeable Paint (2 Coats)
1/8” Baumit RK38 or KG30 Interior Lime
Plaster Top Coat
3/8” Baumit RK38 Interior Lime Plaster
Base Coat
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable thickness to
suit required thermal performance)
5/8” Baumit FL68 Lime Render Base Coat
1/8” Pre-colored Baumit SEP02 Lime
Render Top Coat
Flashing
Stop Bead at Bottom Edge of Lime Render
Brick Veneer at Exposed Foundation
Insulative R-Value* 35.5
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 13”
Embodied Carbon Dioxide Output -4.1
in kilograms per square foot
Recyclable or Biodegradable Content 98%
Approximate Cost Per Square Foot $29
Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wall
While reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,
included in this drawing was accurate at the time of issue, American opening or mechanical conditions.
Lime Technology reserves the right to change specifications at any
time. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.
site and client specific requirements.
website: http://www.americanlimetec.com
LAST REVISED 2010-11-16 email: info@americanlimetec.com
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
3. HC BV-01
RESIDENTIAL CUT-AWAY WALL SECTION
Tradical® Hemcrete® Wall System:
Internal Wood Frame with Brick Veneer Exterior
Vapor Permeable Paint (2 Coats)
Vapor Permeable Magnesium Board
Tape and Mud at Magnesium Board
Joint
Magnesium Board Fastener
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable
thickness to suit required thermal
performance)
2x2 Wood Furring, 16-24” O.C.
Brick Tie
Furring Stop
Air Cavity (ventilated and drained)
Brick Veneer
Mortar Net at Base of Air Cavity
Brick Cavity Vent
Flashing
Insulative R-Value* 29.9
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 18”
Embodied Carbon Dioxide Output -2.1
in kilograms per square foot
Recyclable or Biodegradable Content 96%
Approximate Cost Per Square Foot $35
Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wall
While reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,
included in this drawing was accurate at the time of issue, American opening or mechanical conditions.
Lime Technology reserves the right to change specifications at any
time. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.
site and client specific requirements.
website: http://www.americanlimetec.com
LAST REVISED 2010-11-16 email: info@americanlimetec.com
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
4. HC FC-01
RESIDENTIAL CUT-AWAY WALL SECTION
Tradical® Hemcrete® Wall System:
Internal Wood Frame with Fiber Cement Siding Exterior
Vapor Permeable Paint (2 Coats)
Vapor Permeable Magnesium Board
Tape and Mud at Magnesium Board
Joint
Magnesium Board Fastener
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable
thickness to suit required thermal
performance)
2x2 Wood Furring, 16-24” O.C.
1x2 Vertical Wood Furring, 16-24” O.C.
Air Cavity (ventilated and drained)
Furring Stop
Fiber Cement Siding
Insect Mesh at Base of Air Cavity
Brick Veneer at Exposed Foundation
Wall
Flashing
Insulative R-Value* 29.9
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 14”
Embodied Carbon Dioxide Output -3
in kilograms per square foot
Recyclable or Biodegradable Content 95%
Approximate Cost Per Square Foot $29
Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wall
While reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,
included in this drawing was accurate at the time of issue, American opening or mechanical conditions.
Lime Technology reserves the right to change specifications at any
time. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.
site and client specific requirements.
website: http://www.americanlimetec.com
LAST REVISED 2010-11-16 email: info@americanlimetec.com
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566