DSPy a system for AI to Write Prompts and Do Fine Tuning
Water Gas Shift Reactor Design
1. Water Gas Shift Reactor Design CN2116 Group 28 Introduction Executive Summary Simulation Features Conclusion Ma Haotian Li lan Liu Yi Fei Luo Yu Shan Yu
17. Simulation Results The highest conversion for HTS inlet temperature 320.000000 Celsius is 0.810000 outlet temperature 362.849043 Celsius The highest conversion for LTS inlet temperature 200.000000 Celsius is 0.990500 outlet temperature 208.682034 Celsius HTS reactor volume is 88.687919 m^3 LTS reactor volume is 18.837752 m^3 Total volume is 107.525670 m^3 HTS reactor pressure drop is 14807.220752 Pa LTS reactor pressure drop is 2505.309835 Pa Total pressure drop is 17312.530587 Pa Intro Exe. Summary Simulation Features Conclusion