Does your noise dosimeter give you the edge in hearing conservation?
Hearing loss is the leading workplace injury and the SV 104 personal noise dosimeter helps professionals measure and mitigate workplace noise.
http://www.sensidyne.com/sound-noise-vibration-measurement-svantek/noise-dosimeters/sv-104-noise-dosimeter.php
2. Svantek SV 104 Personal Noise Dosimeter
The SV 104 noise dosimeter truly gives
professionals the edge in hearing conservation.
It is the only badge noise dosimeter with:
PP Real-time octave band analysis for accurate hearing
protector selection data
PP Three simultaneous, independent dosimeter measurements
for OSHA PEL, OSHA HCA, ACGIH, or custom configurations
PP Audio recording for peak or threshold noise-source
identification
PP MEMS triaxial vibration sensor identifying possible
instrument impacts
PP Durable MEMS microphone for greater shock resistance
PP Color OLED display for ease of reading in dim light or direct
sunlight
ShownActualSize
3. Svantek SV 104 Personal Noise Dosimeter
01
02
03
MEMS Microphone
The SV 104 offers a solid state microphone technology built directly into the
dosimeter body. The microphone is robust, resisting impact and is virtually
immune to environmental influences such as temperature and moisture. This
results in a longer life and lower cost of ownership.
Color OLED Display
High-contrast, color graphic display is a first in badge style personal noise
dosimeters and provides better visibility in direct sunlight, under bright lights,
and in dim lighting. Color makes it easier to display large amounts of data
within a limited display area.
Real-time Octave Band Analysis Option
Simultaneous measurement of individual octave bands with overall broadband
noise dose measurements results offer professionals complete information for
the correct prescription of appropriate hearing protection from a single noise
survey. Octave band analysis provides greater measurement effectiveness
while saving costs associated with using additional instruments.
4. Svantek SV 104 Personal Noise Dosimeter
04
05
06
Audio Event Recording Option
Record actual audio samples of noise occurring above the selected threshold
level to identify contributions to dose exposure, verify noise sources, and
validate workplace related noise versus user interference. Audio event playback
is performed through the included PC application.
Micro SD Memeory Card
A high-capacity 8GB memory card enables storage of all dose measurement
results and one-second time history data from all three user profiles, the octave
band analysis data, audio event recording, and voice comments. The large
storage capacity is sufficient for recording numerous noise surveys.
Voice Comment Recording
Record brief audio comments before or after surveys to capture relevant voice
notes such as location information, worker data, and machinery and process
conditions. Voice comments may be played back through the included PC
application.
5. Svantek SV 104 Personal Noise Dosimeter
07
08
09
MEMS Triaxial Vibration Sensor
The embedded triaxial vibration accelerometer measures dosimeter movement
including excessive vibration or impacts that may result in false-positive dose
measurements. The PC software allows users to review vibration data and
determine if affected periods should be removed from the dose calculation.
Lockable Keypad and Display
Eliminate tampering from workers and discourage interference with the
instrument by locking the keypad. The color OLED display may optionally be
blanked out during surveys for further discretion or tamper-avoidance.
Three Independent User Configurable Profiles
Each of the thee independent profiles can be user configured to measure noise
exposure according to specific parameters. Example configurations include
OSHA Hearing Conservation Act (HCA), OSHA Permissible Exposure Level
(PEL), and ACGIH profiles. Simultaneous measurements save time and costs
associated with multiple separate surveys.
6. Svantek SV 104 Personal Noise Dosimeter
10
11
12
Low Power Digital Signal Processing (DSP)
Enhanced DSP capabilities provide sufficient battery life for up to five 8-hour
noise surveys on a single charge. Low power requirements allow charging from
powered USB port or wall plug.
Extended Dynamic Range
The SV 104 measures from under 60 to 140 dB to address all workplace noise
levels of interest. This range permits use even in quieter noise environments
due to the extended low-end range as compared to other badge style
personal noise dosimeters.
Automatic Calibration Technology
Calibration procedures begin automatically when an acoustic calibrator is
placed over the microphone. One button controls accuracy verification at the
start and end of every measurement.
7. Svantek SV 104 Personal Noise Dosimeter
The SV 104 noise
dosimeter gives users
the edge in noise
measurement and
hearing conservation.
8. A company of the SCHAUENBURG International GroupSensidyne, LP | 1000 112th Circle North, Suite 100 | St. Petersburg, Florida 33716 U.S.A.
Tel: 800-451-9444 / +1 727-530-3602 | E-mail: info@Sensidyne.com | Web: www.Sensidyne.com