J.J.M. MEDICAL COLLEGE, DAVANGERE DEPARTMENT OF ANAESTHESIA SEMINAR  ON Face mask ,airway, laryngoscope and endotracheal tube Chair person:                                 Presented by: Dr.Nalinakshamma.SDr.YuvarajShastri MD.DA.,                                                  PG in anaesthesia Professor.
Face mask
Introduction It is the device which allows administration of gases to  the patient from breathing system without introducing  any apparatus to the patients mouth.
  Description A face mask can be made up of black rubber, clear plastics, elastomeric material or combination of these. Parts of the face mask: Body: constitutes the main part of the mask    Transparent body allows observation of                                                                                             moisture, vomitus , secretions etc .
Seal : Comes in contact with the face.Two types are available Pad or cushion – inflated with air  Flap – flexible extension of the body Connector ( orifice/ collar ) : Opposite to the seal Thickened fitting of 22 mm ID Ring with hooks helps in strapping the mask
Specific masks :   1.  Anatomical mask : Can be moulded to conform to the anatomy of face . Has slightly malleable rubber body, a sharp notch for the nose and a curved chin section.
     2. Rendell-baker-soucek(RBS) mask  Designed for paediatric patients < than 10 yrs It has triangular body and low dead space Used in tracheostomy and acromegaly patients
3. Endoscopic mask : Designed to allow mask ventilation during endoscopy It has port or diaphragm in the body to allow fibroscope insertion
4. Scented mask : Scent incorporated into the mask by manufacturer or anaesthesia provider Added for better acceptability and pleasant experience during induction Disadvantage- ethyl alcohol in some flavors may affect accuracy of gas monitors.
   Techniques of use: The face mask should form tight seal on the pts face while fitting comfortably in the user`s hand.  The smallest mask is most desirable because it will cause least increase in dead space, easy to hold & less likely to result in pressure on eyes.        There are several methods
One Hand Method -    the thumb & index finger of left hand are placed on mask body on opposite sides of connector push downward to prevent leak.  The remaining 3 fingers are placed on the mandible such that middle finger is applied to the mentum, ring finger on body of mandible & little finger at angle of mandible to give jaw thrust anteriorly
Two Handed Method –  As it requires both hands, a 2nd person is necessary for assisted or controlled ventilation.  Here thumbs are placed on either side of body of masks, index fingers are placed under the angles of jaw, mandible is lifted & head is extended.  If a leak is present, downward pressure on mask can be increased by anesthesiologist’s chin on the mask elbow
Two Handed Jaw Thrust –  1 person  stands at head end of pt & performs jaw thrust with his left hand at angle of left mandible while  his right hand compresses the reservoir bag.  The 2nd person stands at pts shoulder facing 1st person. This persons Rt hand covers the Lt hand of the 1st person & the Lt hand achieves Rt sided Jaw thrust & mask seal.
Claw Hand Technique –  It is useful for children undergoing short duration procedures.  The Anesthesiologists stands at the side of bed facing the child. The face mask is applied to face by using the Rt hand with the palmar surface facing upwards. The ring & middle finger are placed under the angle of jaw & the index finger & thumb encircle the body of mask.
Dead space in face masks: Face mask and its adaptor increase dead space and it may contribute 30% or more of tidal volume in neonates and infants. It can be reduced by:       a) using smaller size mask.       b) increasing pressure on mask.       c) blowing a jet of fresh gas into the mask.       d) changing the volume of the seal cushion
   Advantages Lower incidence of sore throat   requires less anaesthetic depth than tracheal tube or supraglottic device. No need of muscle relaxants. The face mask may be the most cost efficient method  for short cases.
   Disadvantages  Anesthesiologist`s hands are tied up   higher fresh gas flows are often needed. During remote anesthesia, airway access is difficult ( CT & MRI). Often more episodes of oxygen desaturation & require more intraoperative airway manipulations
   Complications  Skin problems- dermatitis, pressure necrosis. Nerve injury. Eye injury – conjunctivalchemosis, eyelid edema & corneal injuries. Gastric Inflation Latex allergy Lack of co-relation between arterial & end tidal CO2. Environmental Pollution with anesthetic gases Jaw Pain & User fatigue.
Airway
   Introduction: A fundamental responsibility of anaesthesia providers is to maintain a patent airway.  The airway passage has a rigid posterior wall and a collapsible anterior wall consisting of the tongue and epiglottis.  Under anaesthesia the tongue & epiglottis falls back into the posterior pharynx occluding the airway.  The purpose of airway is to lift the tongue & epiglottis away from the posterior pharyngeal wall & maintain a patent airway.
   Terminology : Artificial airway - any device that aims to maintain oral or nasal air passages. It may be  Simple supraglottic devicesuch as oropharyngeal or nasopharyngeal airways. These may not be sufficient to maintain the patency of airway on their own & may require pts jaw to be supported as well.  Augmented supraglottic devicesuch as LMA & airway management device Infraglottic devicessuch as Endotrachealtubes,tracheostomy tubes, jet ventilation catheters.
Oropharyngeal Airways Description     It extends from lips to pharynx, fitting between tongue & posterior pharyngeal wall. Made up of elastomeric or plastic materials. Parts are Flange it is at buccal end to prevent it from moving deeper into mouth & may also serve to fix airway in place. Bite Portion it is straight & fits between teeth & gums.. Curved portion extends backwards to correspond the shape of tongue & palate.
    The American National Standard specifies that the size of oral airways be designated by a no. i.e the length in cms.
    SPECIFIC AIRWAYS Guedel Airway     Most frequently used airway & has large flange & reinforced bite portion with tubular channel for air exchange & suctioning.
    Cuffed Oro-Pharyngeal Airway   It is Guedel`s Airway with an inflatable cuff designed to seal the oropharynx. It has an integral bite block & a 15mm connector for attachment of the breathing circuit. The cuff is inflated with air to displace the base of tongue & form a low pressure seal with the pharynx & provide an open airway.
Patil-Syracuse Endoscopic Airway     It was designed to aid fiber-optic intubation. It is made       of aluminium.      It has lateral channels & a central groove on the lingual surface to allow passage of fiberscope. A slit in distal end allows fiberscope to be manipulated in antero-posterior direction but limits lateral movements.
   Berman Intubating Airway     It is tubular along its entire length. It is open on 1 side so that it can be split & removed from around a tracheal tube. It can be used as an oral airway or as an aid to fiberoptic or blind oro-tracheal intubation
    Williams Airway Intubator   Designed for blind tracheal intubation & can also be used for fiberoptic intubation or as an oral airway.  It is available in 2 sizes #9 & #10 which will admit upto 8 & 8.5 mm tracheal tube respectively.  The proximal half is cylindrical while distal half is open on lingual surface.
OvassapianFiberopticIntubating Airway  Designed for fiberoptic intubation.  Has a flat lingual surface which gradually widens at distal end & 2 vertical sidewalls at the buccal end. Between the sidewalls are a pair of guide walls that curve towards each other which are flexible & permit removal of airways around the tracheal tube.  The proximal half is tubular & acts as bite block. The distal half is opened posteriorly & it can accommodate tracheal tube upto 9mm id
.      METHODS OF INSERTION Pharyngeal & laryngeal reflexes should be depressed before an airway is inserted to avoid coughing & laryngospasm. Selecting the correct size is important. Correct size is estimated by holding the airway next to pts mouth & the tip should be at the angle of mandible.  The best criteria for proper size & position is unobstructed gas exchange
    Oral airway may be inserted in 2 ways  The jaw opened with  Lt hand.  The airway is inserted with its concave side towards the upper lip & when the junction of bite portion & curved section is near the incisors, the airway is rotated 180° & slipped behind the tongue in the final position .
A tongue blade is used to push forward and depress the    tongue & the airway is inserted with concave side towards the tongue & is advanced.
   OTHER USES May be used to prevent pt from biting & occluding ETT. Protect the tongue from biting  To facilitate suctioning To obtain better mask fit.
   NASOPHARYNGEAL AIRWAY (nasal trumpet/ nasal airway) It   extends from nose to pharynx, the pharyngeal end should be below base of tongue but above the epiglottis.  A nasal airway is better tolerated than oral airway if the pt has intact airway reflexes. Description     It resembles a shortened tracheal tube with a flange at the outer end to prevent it from completely passing into the nares. It is made up of plastic or rubber & the size is designated by the inner diameter in mm
Nasopharyngeal airway
   specific types   Linder Nasopharyngeal Airway It is plastic with large flange & flat distal end and is supplied with introducer which has balloon on its tip. Before insertion, the introducer is inserted into the airway until the tip of balloon is just past the end.  Air is injected until the balloon tip is inflated to approx outer diameter of tube.  The complete assembly is lubricated & inserted through the nostril.  After it is in place, the balloon is deflated & introducer is removed.
Cuffed Nasopharyngeal Airway It is similar to a short, cuffed tracheal tube. It is inserted through the nose into the pharynx; cuff inflated & then is pulled back until resistance is felt. Binasal Airway It consists of 2 nasal airways joined together by an adaptor for attachment to the breathing system. Can be used to administer anesthesia
INSERTION The diameter of nasal airway should be the same as needed to insert the tracheal tube (0.5-1.0mm smaller than oral tracheal tube). Before insertion it should be lubricated thoroughly along its entire length. The airway is held with the bevel against septum & gently advanced posteriorly while being rotated back & forth.
COMPLICATIONS Airway obstruction Epistaxis Ulceration & Necrosis Dental Damage CNS trauma Laryngospasm & Coughing. Aspiration or Swallowing of part or all of the airway. Latex Allergy Gastric distension.  
Laryngoscopes
Introduction A laryngoscope is an instrument used to view larynx and adjacent structures, most commonly for introducing tube into the trachea    Laryngoscopes can be considered under two broad headings.  Retractor type like the Macintosh laryngoscope. Fibreoptic Laryngoscope     Two types :         Rigid fibreoptic laryngoscope        Flexible fibreoptic laryngoscope.
  History  In 1885, Alfred Kirstein first used esophageal scope to visualize the larynx.  In 1907, Chevailior Jackson introduced the separable laryngoscope with a U handle.  In 1913, Janeway introduced the first fashioned scope specially for anesthetist. It was the first to incorporate battery in the handle
    RIGID LARYNGOSCOPES: These are manufactured either as single piece or separate detachable blade and handle.  For detachable handle & blade the light source is energized when blade & handle are locked in operating position.  A single piece laryngoscope has a switch on handle that controls power to lamp.     Rigid Laryngoscope has 2 parts     1. Handle       2. Blade .
 1. Handle:     The handle is the part that is held in the   hand during use.  It provides the power source for the  light. Most often this is from disposable batteries. Fibreoptic illuminated laryngoscope may use a remote electrically operated light source. The handle is fitted with a hinge pin that fits a slot on the base of the blade..
Handles are available in variable sizes & have rough surface for improved grip.
Although most blades form right angle with the handle when ready to use. The angle may also be acute or obtuse.  An adapter may be fitted between the handle and the blade to allow  angled to be altered. Howland lock is such an example. The patil-syracusehandle can be positioned and locked in four different positions (45°, 90°, 135° and 180°).
Patil-syracuse handle
2. Blade The blade is a component that is inserted into the mouth.  When a blade is available in more than one size, blades are numbered, with the number increasing with size.
     The parts of the blade include   base  heel   spatula/tongue  flange  web  tip   light source.
   Types of Blades    There are several types of blades which may be advantageous in particular situations.    Macintosh Blade The Macintosh blade is one of the most popular. The tongue has a smooth, gentle curve that extends from the base to the tip. In cross-section, the tongue, web. and flange form a reverse 'Z'. Cervical spine movement is greater compared to the Miller blade.
   Left handed Macintosh Blade The left handed Macintosh blade has the flange on the opposite side from the usual Macintosh blade. This blade may be useful for the abnormalities of right side of the face or oropharynx, left handed persons, intubating in the right lateral position, and positioning a tracheal tube directly on the left side of the mouth.
   Improved Vision Macintosh Blade The Improved Vision (IV) Macintosh blade is similar to the standard version except that the mid portion of the tongue is concave to allow greater visualization of the larynx
    Polio Blade The blade is offset from the handle at an obtuse angle to allow intubation of patients in iron lung respirators or body jackets   Patients with obesity, breast hypertrophy, kyphosis with severe barrel chest deformity,  short neck, or restricted neck mobility.  Disadvantages of this blade are that little force can beapplied and control is minimal
Oxiport Macintosh (Mac/port) The Oxiport Macintosh blade a, conventional Macintosh blade with a tube added to deliver oxygen
Tull Macintosh The Tull (suction) blade is a modified Macintosh that has a suction port near the tip. The suction channel extends next to the handle and has a finger controlled valves so that suction can be controlled by the laryngoscopist.
   Fink Blade The Fink blade is another modification of the Macintosh.  The tongue is wider and has a sharper curve at the distal end. The height of the flange is reduced, especially at the proximal end.  The light bulb is placed farther forward than on the Macintosh.
Bizarri-Guiffrida Blade The Bizarri-Guiffrida blade is a modified Macintosh. The flange is removed, except for a small part that encases the light bulb.  This was made to limit damage to the upper teeth.  The blade is useful for patients with a limited mouth opening, prominent incisors, receding mandible, short & thick neck or anterior larynx
   Miller Blade The tongue is straight with a slight upward curve near the tip. In cross-section the flange, web, and tongue form a C with the top fattened. The lamp may be either on the right or left side of the blade.
Oxiport Miller Blade The Oxiport Miller (also called Miller/port, oxyscope) blade has a built-in tube that allows delivery of oxygen or other gases during intubation. The tube also may be used for suction. Insufflation of oxygen during intubation using this blade has been found to decrease oxygen desaturation in spontaneously breathing anesthetized patients.
Tull Miller Blade Tull (suction) Miller blade is a standard Miller blade with a suction tube whose port ends near the tip of the blade.  Near the handle is a finger-controlled port that allows control of suction with a finger.
    Mathews Blade The Mathews blade is a straight blade with a wide and flattened petalloid configuration tip. It is designed for difficult nasotracheal intubations.
Alberts Blade It has a cut-away flange to increase the visibility. There is recess to facilitate tracheal tube insertion. The blade forms a 67° angle with the handle. It is used for pediatric pt.
    Double Angle Blade The spatula of double angle blade has 2 angulations 20° & 30°, to improve lifting of the epiglottis.  The flange has been eliminated. The bulb is located at left edge of the blade between the 2 curvatures. The blade may be useful for the pt with anterior larynx.
   Flexible tip blade It has a hinged tip that is controlled by lever attached to the proximal end of the blade When the lever is pushed towards the handle,the tip of the blade is flexed. Eg: Mc-Coy, flipper,flex tip etc. It may improve the chances of successful intubation by elevating the epiglottis particularly in case of difficult intubation. Less force and less stress response.
Mc Coy blade
Techniques of use    positioning the head : The head should be positioned so that the passage-way to the larynx is brought into a straight line for the best possible view of the vocal cords.  The optimal position for most patients is flexion of 35° of the lower cervical spine and extension of the head of 85-90° at the atlanto-occipital level, the so-called sniffing position.   In children, it may be unnecessary to flex the lower cervical vertebrae, and in neonates it may be necessary to elevate the shoulders because the head is relatively larger.
The laryngoscope handle is held in the left hand. The fingers of the right hand are used to open the mouth and spread the lips apart.  The blade is inserted at the right side of the mouth. This reduces the likelihood of incisor teeth damage and helps push the tongue to the left.  The blade is advanced on the side of the tongue toward the right tonsillarfossa, so that the tongue lies on the left side of the blade.   When the right tonsillarfossa is visualized, the tip of the blade is moved toward the midline. The blade is then advanced behind the base of the tongue, elevating it, until the epiglottis comes into view.
    There are two methods for elevating the epiglottis, depending on whether a straight or curved blade is being used.     Straight Blade Technique The blade is made to scoop under the epiglottis and lift it anteriorly. The vocal cords should be identified. If the blade is advanced too far, it will result in elevation of the larynx as a whole rather than exposure of the vocal cords.  The straight blade can also be inserted into the vallecula and used in the same manner as a curved blade.
 Curved Blade After the epiglottis is seen, the blade is advanced until the tip fits into the valleculla.  Traction is then applied along the handle, at right angles to the blade to carry the base of the tongue and the epiglottis forward. The glottis should come into view
     RIGID FIBEROPTIC LARYNGOSCOPES     Bullard laryngoscope Description It has a rigid metal blade specially shaped to follow the contour of the oropharynx.  Fibreoptic bundles for illumination & operatory viewing are housed in a sheath on the posterior aspect of blade.  A viewing arm with eye-piece extends at a 45°angle from the handle. A video camera can be attached to eyepiece for remote viewing. A working channel extends from the scope body to the point where the light bundles end at the tip. It can be used for suction, oxygen insufflations, administration of L.A/ Saline, or jet ventilation catheter.
   3 sizes are available : Pediatric Pediatric long – for babies upto 8-10yrs of age. Adult version – for children more than 10yrs & adults.  Advantages : It causes less cervical spine movement than conventional laryngoscopy. Requires mouth opening of only 7mm. Rapidity of intubation Low risk of failed intubation or trauma to lips or teeth.
Disadvantages: Requires experience & Maintainence of skills & is somewhat expensive. Intubation with ETT >7.5mm may be more difficult. Certain ETT & Double lumen tubes will not fit the stylet
WuScope Description :  It combines a rigid, tubular blade & a flexible fiberscope.  Flexible Fiberscope portion. The fiberscope has short light & image transmitting fibreoptic bundles & tip deflection control. Blade portion      It has 3 detachable metal parts - handle, main blade & bivalve element.
Handle- cone shaped tube that receives the fiberscope at the top & connects to the main blade at the base. The handle to blade angle is 110°. Main blade & bivalve element are anatomically shaped. When positioned together, they form 2 passage ways- a larger 1 for suction catheter or ETT & a smaller 1 for fiberscope.                  An oxygen channel is alongside the slot for fiberscope.                  Different sizes of blades & bivalve element can be used with the handle. The adult blade can accommodate ETT upto 8.5mm
    Advantages  Can be used successfully to place both tracheal & double lumen bronchial tubes in difficult-to-intubate pts. No forceps or stylet is needed so risk of airway injury is low. Suctioning & oxygen administration can done simultaneously. Unlike flexible fibreoptic endoscopy, 1 can view ETT passing through glottis into trachea. There is no need for head extension or tongue lifting.
   Disadvantages  Requires experience or Maintainence of skills & high initial cost. Time required to assemble or disassemble the device is more. Application of cricoids pressure decreases the ease of intubation while using this device.
UpsherScope    Description  It consists of C-shaped metal blade, shaped to approximate curve of oropharynx.  The distal part has an upward curve. To the lt are 2 tubes that carry fibreoptic bundles.  Proximally the viewing bundle terminates in the eye piece while the light bundle makes contact with the light source at the handle.. It is presently available only in adult size.
Advantages  It can be used with all size of adult ETT. Useful to intubate pts with difficult airways in a reasonable time.    Disadvantages Not suitable for naso-tracheal intubation. In routine intubation this scope has demonstrated no advantages over the conventional laryngoscopes
   VIDEO LARYNGOSCOPE    It can be created by attaching video system to a flexible laryngoscope or an optical stylet. It has many advantages –  The displayed anatomy is magnified & a larger viewing angle is provided. In addition to allowing laryngoscopy & intubation to be visualized, it can be used to observe vocal cord movements after thyroid surgery, verify tracheal tube position & aid in tracheal tube exchange. Results in less neck movement than conventional laryngoscopy. By projecting the image it makes a good teaching tool Limitations of these device is the need for a video endoscopy monitoring system.
  VIDEO MACINTOSH INTUBATING LARYNGOSCOPE It has macintosh blade attached to the handle.  The image- light bundle is threaded through a small guide in the blade & advanced 2/3 of the length of the blade.  Provides better view than traditional macintosh laryngoscope.
   GLIDE SCOPE Description : It has a miniature digital camera underside of a plastic blade. A light emitting device( LED) mounted beside the camera provides illumination.  Blade has a 60° bend at the midpoint The Glide Scope is available in adult & pediatric size. Studies shows this scope yields a comparable or superior glottis view compared to direct laryngoscopy. It causes less cervical movements than macintosh blade
    FLEXIBLE FIBEROPTIC LARYNGOSCOPE Introduction: The 1st use of flexible fibreoptic technology in the airway management can be credited to Dr P Murphy, who in 1967 invented Choledochoscope for intubation of trachea. The flexibility of these devices means that they can be made to follow virtually any anatomical space to return an image of the objective. The technique of flexible fibreoptic intubation has become a gold standard for management of difficult laryngoscopy.  This has tended to create the impression that the technique is solution to all difficult airways, but this is patently not so.
Principles & Design The pathway through which the illumination & the image pass consists of thousands of very fine glass fibers, each typically of 10µm in diameter. Each fiber consists of a central glass core surrounded by a thin cladding of another type of glass with different refractive index. As a result of difference in refractive indices, light entering the glass fiber undergoes total internal reflection along the length of the fiber to emerge at the other end. For image transmission, the arrangement of fibers relative to one another must be identical at either end of the bundle, as each fiber carries tiny portion of the overall image. This is called a COHERENT BUNDLE.
Parts     It is composed of several parts, a light source, handle & flexible insertion portion. The handle is the part to be held in hand during use. It includes the eyepiece, focusing ring, working channel port & the tip control lever.    The insertion tube carries      2 light bundles     1 image bundle     1 working or biopsy channel     2 angulation wires, which control the more flexible tip of      device
These are held together with a stainless steel spiral wrap followed by a stainless steel braid & covered by waterproof material, to give a rigid cross section while allowing overall flexibility. The fiberscope is axially rigid to twisting forces thus rotation of the control handle results in similar rotation of the tip.   The fiberscope uses a powerful  external cold light source so that the tissues are not damaged by radiant heat.
Usage  The intubatingfiberscopes are available with insertion tubes ranging in size from 2.5mm ext diameter to over 6mm with proportionately larger working channels.   A device with ext diameter of 3.5mm is optimal for use in adults.  The advent of the miniature video camera has revolutionized fibreoptic endoscopy.
Fibreoptic Intubation It can be performed via oral or nasal route. The fiberscope is inserted & advanced behind the tongue & into the larynx. Once in the trachea, a tracheal tube which has been previously loaded onto the fiberscope is advanced off the scope into the trachea & then the fiberscope is removed. Oral intubation is considered more difficult than nasal intubation
Advantages  Reliable approach to the difficult airway management. Facility to record images for review & documentation. Improvements in teaching techniques. Disadvantages More expensive & fragile & difficult to use than rigid laryngoscope. Requires more time than rigid laryngoscopy. Requires considerable experience & skill Maintainence Laryngeal trauma may occur.
  Complications of laryngoscopy 1. Dental injury 2. damage to soft tissue and nerves 3. Injury to cervical spinal cord 4. Circulatory changes 5. Swallowing or aspiration of foreign body. 6. Shock or Burns  7. Laryngoscope malfunctions 8. Disease transmission 9. TMJ Dislocation.
Endotracheal tubes
    HISTORY    In 1667 Robert Hook kept a dog alive for over an hour by ventilating its lungs with a pair of bellows tied into the trachea.   In 1871, Friedrich Trendelenburg developed a cuffed catheter for insertion through a tracheostomy to prevent soiling of the lungs during operation of the upper airway.   In 1878, the Glasgow surgeon William MacEven placed a metal tube by manual palpation through the mouth into the trachea & administered chloroform anaesthesia.   In 1950s, the use of cuffed ETT became standard anesthetic practice.
    DESCRIPTION:  An endotracheal tube is one through which anesthetic gases and respiratory gases are conveyed into and out of the trachea.  It has tracheal & machine end The bevel is defined as the slanted part of the tube at the tracheal end.  When, an opening in the tube is present on the opposite side of the bevel, it is designated as Murphy's tip endotracheal tube.
     REQUIREMENTS OF IDEAL ET TUBE      1) Inertness      2) Smoothness of outer surface to avoid damage to mucosa      3) Inner surface should be smoothed and non-wettable             to prevent building of secretions.      4) Non-inflammable      5) Transparent      6) Easily sterilized      7) Non kinking
 8) Sufficient strength to allow thin wall construction  9) Thermoplasticity to confirm to anatomic passage and to be self centering within the trachea. 10) Non reactive with lubricants or anesthetic agents 11) Latex free 12) Non injurious catheter tip     Currently used tubes are manufactured from synthetic rubber, plastic materials and silicone.
       GENERAL PRINCIPLES  RESISTANCE AND WORK OF BREATHING     A tracheal tube places a mechanical burden on spontaneously breathing patient. It is a source of more resistance and is an important factor in determining the work of breathing. The factors determining the resistance include:     1) Internal diameter: The tube with thick wall decreases the ID and thereby increases the resistance and vice-versa.        2) Length: Decreasing the length of the tube decreases the resistance.    3) Configuration: Abrupt change in the diameter and direction increases the resistance. Gentle curve connectors offer less resistance than right-angled ones as there will be increased resistance because of turbulent flow of gases.
   DEAD SPACE  The volume of tracheal tube and connector is usually less than that of the natural passage.  Dead space is normally reduced by intubation.  In pediatric patients long tubes and connectors may increase the dead space considerably.
   STANDARD MARKING OF ETT The markings are situated on the bevel side above the cuff & are read from pt end to machine end  Type of the tube: Oral or nasal or oral/nasal  Size: ID in mm   External diameter may also be indicated.  Manufacturer's name or trade mark
Tube has Graduated markings, showing the distance in cms from the patient end.  Precautions are usually noted: Disposable/Do Not Reuse Implantation tests (IT) or Z-79 indicating the tube has been tested for tissue toxicity & accomplish ANSI standard.  Opaque lines may also be included at the patient end or along full length.
   CUFF SYSTEM     A Cuff system consists of the cuff & inflation system. The purpose of cuff system is to provide a seal between tube & tracheal wall to prevent passage of pharyngeal contents into the trachea & ensure no gas leaks past the cuff.     The cuff also serves to center the tube in trachea.
      INFLATION SYSTEM    1) Inflation valve: When  a syringe  tip is inserted, a plunger is displaced from its seat & gas can be injected into the cuff.  Upon removal of the syringe the valve seals and gas cannot escape.    2)Pilot balloon: Its function is to give an indication of inflation or deflation of the cuff and a rough idea of the cuff pressure.
  3) External inflation tube: The standard specifies ,            a)The external diameter should not exceed 2.5mm             b) The inflation tube should be attached to the ETT at asmall angle.             c) The tube should extend at least 3cm beyond the machine end of the ETT before a pilot balloon or inflation valve is incorporated.   4) Inflation lumen: This connects the inflation tube to the cuff. It is located within the wall of the tracheal tube.
    CUFF: The cuff is a inflatable sleeve near the patient end of ETT.  The cuff material should be strong and tear resistant but thin, soft and pliable.  Cuffs are usually made of the same material as the ETT.
   CUFF PRESSURE Intracuff pressure and pressure on tracheal wall: It is desirable that cuff seals the airway without extending so much pressure on the trachea so that its circulation is not compromised or trachea is dilated.  When cuff is inflated in the trachea, there is a linear decrease in the perfusion. It is reduced when the lateral pressure on the tracheal wall attains 30cm of H20 (22mmHg) and ceases completely at 50cm of H20 (42mmHg).  So it is recommended that the pressure on the lateral tracheal wall should be kept between 25-34cm of H20.
Intracuff pressure and use of nitrous oxide: The resting intracuff pressure and volume of the cuff inflated with air rise during nitrous oxide anesthesia, which results in ischaemia of the tracheal mucosa or compression of the tube, and increase in volume may lead to cuff herniation.
Steps to prevent the increasing pressure includes the following:    a) Filling the cuff with gas mixture to be used for anesthesia or saline     b) Fitting the cuff system with pressure relief valve or pressure regulating devices.    c) Use of special system e.g. Lanz pressure regulating valve, sponge cuff and special tubes like Brandt tubes.    d) Monitoring cuff pressure and deflating the cuff as needed.
   Types of cuffs:     a) Low volume high pressure     b) High volume low pressure  a) Low volume high pressure cuff: They have a small diameter at rest and low residual volume.            It requires a high intra-cuff pressure to achieve a seal with the trachea.            It has a small area of contact with the trachea and distends and deforms the trachea to a circular shape.  .
The intra-cuff pressure and lateral pressure on the tracheal wall increase sharply as increments of air are added to the cuff.              For this reason use of largest ETT has been advised, so that the cuff will be minimally inflated when a seal is created
   Advantages: Usually reused, Less expensive  Offers better protection against aspiration Better visibility during intubation than low pressure cuffs. There is also low incidence of sore throat.    Disadvantages; The most serious risk associated with these cuffs is ischemic damage to the trachea following prolonged use.
   b) High volume low pressure cuffs: They have a high resting volume, large diameter and a thin competent wall.                 As it is inflated, it first touches the trachea at its narrow point. As cuff inflation continues the area of contact become larger and the cuff adopts itself to irregular tracheal surface.                 If the cuff inflation is continued the area in contact will be subjected to increasing pressure and trachea will be distorted to a circular cross section similar to high pressure cuff.
    Advantage : It is relatively easy to pass devices such as esophageal stethoscope, temperature probes, nasogastric tubes around a low pressure cuffs.    Disadvantage:  These tubes are more difficult to insert, Obscure the view of the tube tip and larynx The cuff is more friable and thus more likely to be torn during intubation.  Incidence of  sore throats is greater with these tubes. It may not effectively prevent fluid leakage into lower airway.
THE GUIDELINES TO DETERMINE THE SIZE OF ETT: Ideal tube in average Adult male – 8.5mm ID  Ideal tube in an average Adult female - 7.5mm ID.   Age is recognized as the most reliable indicator of appropriate ETT size for children. 3 months & less 	------	3 mm ID 3 - 9 months  	------	3.5 mm ID Older than 1 year ------	ID in mm = (16 + age in years)/4
 Younger than 6 years  ---3.5 + age in years/3 = ID in mm Older than 6years   ----	4.5 + age in years / 4 = ID in mm Infants below 1kg -----	2.5mm  Infants 1-2 kg 	------	3.0 mm  Infants 2-3 kg 	------	3.5 mm  Infants 3 kg 	------	4.0 mm    Choosing a tube whose external diameter is same width as the patient's distal little finger
  Other recommendations for size of ET tubes
   DEPTH OF INSERTION    The tube should be in the middle third of the trachea with the head in neutral position. The following calculations can be used.     1) Length in cm =  age/2  +  12     2) Length in cm = weight in kg/5 + 12     3) Length in cm = height in cms/10 + 5     4) Length in cm = 3 ×  ID (mm)
In adults, the tube should be passed until the cuff is 2.25 to 2.5cm below the vocal cord In average size adult patients, securing the tube at the anterior incisor at 23cm in males and 21cm in females will usually avoid endobronchial intubation.  For nasal intubation 5cm should be added to these length for positioning at the nares.
   SPECIFIC ET TUBES     Cole tube:  It is uncuffed ETT, designed for pediatric patients. The patient end is smaller in diameter than the rest of the tube  They are sized according to the internal diameter of the tracheal portion. It ranges from 2mm to 5mm.. It is recommended for neonatal resuscitation but not for long term intubation. Disadvantage of this tube is that it cannot be used nasally
   Spiral embedded tubes: Also known as Armored tube. These tubes have a metal or nylon spiral woven reinforcing wire covered both internally and externally by rubber, PVC or silicone.  A stylet is often needed for intubation.  These tubes are esp useful in situations where the tube is likely to be bent or compressed as in head & neck surgery
   Advantages:  Primary advantage of tube is resistance to kinking and compression.  The portion of the tube outside the patient can be easily angled away from the surgical field without kinking  Can be used for patients with Tracheostomies    Disadvantages: Tube may rotate on the stylet during intubation.  Insertion through nose & intubating LMA is difficult.  Fixation of these tubes are more difficult.  If the patient bites the tube it will cause permanent deformity resulting in obstruction of the tube.
   Preformed tubes/Ring-Adair-Elwyn (RAE):  It is preformed to facilitate the head & neck surgeries. The tubes are available in cuffed, uncuffed ,nasal and oral version. There is apreformed bend in the tube that may be temporarily straightened for suctioning.  Each tube has a rectangular mark at the center of the bend. Distance from this mark to the distal tip is printed on each tube.
Oral RAE tubes are shorter than the nasal ones. The external portion is bent at an acute angle so that when in place it rests on patients chin & the connector over the pts chest.  Nasal RAE has a curve opposite to the curvature of the oral tube, so that when in place the outer portion of the tube is directed towards patient's forehead
   Advantages:  Easy to secure and reduce the risk of unintended extubation.  Breathing system remains away from surgical field     Disadvantages:  It offers more resistance than conventional tubes. Suctioning is difficult
Laryngectomy tube: Designed for insertion into a tracheostomy site.  The tube is preformed in a J configuration at the pt end. This allows the part of the tube external to the patient to be directed away from the surgical field.  The tip may be short and/or without a bevel to avoid inadvertent advancement into a bronchus.
Injectoflex: It is used for laryngeal microsurgery. It is a short cuffed silicone tube designed to be placed below the vocal cords.  The tube has an embedded wire spiral to prevent kinking and compression. The cuff inflation lumen and the inflation tube are integrally joined in a sheath with a malleable introducer.
Microlaryngeal tracheal surgery tube : Is available with an ID of 4, 5or 6mm, each of which has the same length and cuff diameter as a standard 8mm ID tube. Designed for microlaryngeal tracheal surgery. The small diameter provides better surgical access  The problems with this tube are incomplete exhalation & occlusion.
Endotrol tubes: A tip control system is incorporated in this tracheal tube to change the direction of the tip. This tube has ring loop at the machine end that is connected to the tip with a cable Pulling the ring causes the tip of the tube to move anteriorly.  This is useful when laryngoscopy is difficult and only epiglottis is seen.
   Tubes with extra lumens:  Tubes are available with one or more separate lumens terminating near the tip.  They are useful for respiratory gas sampling, airway pressure monitoring, injection of fluids and drugs & jet ventilation.
    The LITA (Laryngotracheal Instillation of Topical anaesthesia)  Has additional small bore channel within the concave surface of the tube. 10 small holes at the distal 13cm of the tube allows the injected medication to be spread both above & below the cuffs.  This can provide a smooth emergence from anesthesia without coughing in most cases.
   EMG Reinforced Tube This tube is designed to monitor recurrent laryngeal nerve electromyogram activity during surgery. The tube is wire-reinforced & has 4 stainless steel electrodes above the cuff. The electrodes are connected to a monitor.
  Laser-shield II Tracheal Tube: It is designed for use with CO2 and KTP lasers.  Made from silicone with an inner aluminium wrap and a smooth Teflon outer coating.  The cuff is not laser resistant & contains methylene blue crystals.  It should be inflated with water or saline solution.  .
Cottonoids for wrapping around the cuff are supplied with each tube.These must be moistened and kept moist during the entire procedure    Disadvantage : Exposure of unprotected parts of the tube proximal & distal to cuff can result in rapid combustion. The methylene blue crystals may not fully dissolve & may obstruct the pilot tube, making it impossible to deflate.
Laser-Flex Tubes: Laser flex tube is a flexible stainless steel tube with a smooth surface designed for used with C02 and KTP (potassium-titanylphosphate) lasers. Adult version has two PVC cuffs and PVC tips with Murphy eye. The tube cuffs are inflated by two separate inflation tubes. The distal cuff can be used if proximal one is damage by laser.
The cuff should be filled with saline. The distal cuff should be filled first until sealing occurs, then the proximal cuff is filled with saline coloured with methylene blue. Problems with the laser flex  tube include  stiffness, roughness, cannot be trimmed.  The double cuff adds to the time of intubation and extubation.
Lasertubus: This is made of white rubber & has a cuff-within-a cuff design.  If the outer cuff is perforated by a laser beam, the trachea will still be sealed by inner cuff. The inner cuff is filled with air & outer with water or saline.  The shaft above the cuff is covered by a corrugated silver foil, which is covered by merocel sponge that should be moistened with saline before use. It is recommended for use with argon, NdYAG, CO2 lasers.
   Hi-Lo Evac Tube It incorporates dedicated channel which can be used to clear secretions below the vocal cords but above the cuff.  The lumen may be blocked by secretions.
   Hi-Lo Jet Tube     It is an uncuffed tube with additional lumen that can be used for Jet ventilation, monitoring airway pressure, sampling respiratory gases or administering local anesthetics.
      REFERENCES     Understanding Anaesthesia Equipment, 5th Edition, Jerry A. Dorsh and Susan E. Dorsh Anaesthetic Equipment, 5th Edition, CS Ward   Clinical Anaesthesiology, 4Ih Edition, GE Morgan Benumoff s - Airway management Understanding paediatricanaesthesia – Rebecca  Jacob
Thank you

More Related Content

What's hot

Mapleson breathing systems
Mapleson breathing systemsMapleson breathing systems
Mapleson breathing systemsdrdeepak016
 
Anaesthesia Workstation checklist and safety features
Anaesthesia Workstation checklist and safety features Anaesthesia Workstation checklist and safety features
Anaesthesia Workstation checklist and safety features ZIKRULLAH MALLICK
 
SAFETY FEATURES OF ANAESTHESIA MACHINE
SAFETY FEATURES OF ANAESTHESIA MACHINESAFETY FEATURES OF ANAESTHESIA MACHINE
SAFETY FEATURES OF ANAESTHESIA MACHINEMAHESWARI JAIKUMAR
 
Circle system low flow anesthesia
Circle system low flow anesthesiaCircle system low flow anesthesia
Circle system low flow anesthesiaDrgeeta Choudhary
 
Difficult airway
Difficult airwayDifficult airway
Difficult airwayimran80
 
Inhalational Anesthetics; Isoflurane and Sevoflurane.pptx
Inhalational Anesthetics; Isoflurane and Sevoflurane.pptxInhalational Anesthetics; Isoflurane and Sevoflurane.pptx
Inhalational Anesthetics; Isoflurane and Sevoflurane.pptxMahmood Hasan Taha
 
Safety features of anaesthesia machine
Safety features of anaesthesia machineSafety features of anaesthesia machine
Safety features of anaesthesia machineAshish Dhandare
 
The basic anaesthesia machine
The basic anaesthesia machineThe basic anaesthesia machine
The basic anaesthesia machinehrishi bharali
 
Supraglottic airway device
Supraglottic airway deviceSupraglottic airway device
Supraglottic airway deviceDebojyoti Dutta
 
Mapleson circuits
Mapleson circuitsMapleson circuits
Mapleson circuitsArun Shetty
 
Patient positioning and anaesthetic consideration
Patient positioning and anaesthetic considerationPatient positioning and anaesthetic consideration
Patient positioning and anaesthetic considerationIqraa Khanum
 
Supraglottic Airway Device
Supraglottic Airway DeviceSupraglottic Airway Device
Supraglottic Airway DeviceDebojyoti Dutta
 

What's hot (20)

Mapleson breathing systems
Mapleson breathing systemsMapleson breathing systems
Mapleson breathing systems
 
Breathing systems
Breathing systemsBreathing systems
Breathing systems
 
Medical gas cylinders
Medical gas cylindersMedical gas cylinders
Medical gas cylinders
 
Anaesthesia workstation
Anaesthesia workstationAnaesthesia workstation
Anaesthesia workstation
 
Anaesthesia Workstation checklist and safety features
Anaesthesia Workstation checklist and safety features Anaesthesia Workstation checklist and safety features
Anaesthesia Workstation checklist and safety features
 
SAFETY FEATURES OF ANAESTHESIA MACHINE
SAFETY FEATURES OF ANAESTHESIA MACHINESAFETY FEATURES OF ANAESTHESIA MACHINE
SAFETY FEATURES OF ANAESTHESIA MACHINE
 
Laryngeal mask-airway
Laryngeal mask-airwayLaryngeal mask-airway
Laryngeal mask-airway
 
Circle system low flow anesthesia
Circle system low flow anesthesiaCircle system low flow anesthesia
Circle system low flow anesthesia
 
Difficult airway
Difficult airwayDifficult airway
Difficult airway
 
Anaesthesia machine 2
Anaesthesia machine 2Anaesthesia machine 2
Anaesthesia machine 2
 
Inhalational Anesthetics; Isoflurane and Sevoflurane.pptx
Inhalational Anesthetics; Isoflurane and Sevoflurane.pptxInhalational Anesthetics; Isoflurane and Sevoflurane.pptx
Inhalational Anesthetics; Isoflurane and Sevoflurane.pptx
 
Anaesthesia machine 1
Anaesthesia machine 1Anaesthesia machine 1
Anaesthesia machine 1
 
Safety features of anaesthesia machine
Safety features of anaesthesia machineSafety features of anaesthesia machine
Safety features of anaesthesia machine
 
Vaporizers
Vaporizers Vaporizers
Vaporizers
 
Oropharyngeal Airway.pptx
Oropharyngeal Airway.pptxOropharyngeal Airway.pptx
Oropharyngeal Airway.pptx
 
The basic anaesthesia machine
The basic anaesthesia machineThe basic anaesthesia machine
The basic anaesthesia machine
 
Supraglottic airway device
Supraglottic airway deviceSupraglottic airway device
Supraglottic airway device
 
Mapleson circuits
Mapleson circuitsMapleson circuits
Mapleson circuits
 
Patient positioning and anaesthetic consideration
Patient positioning and anaesthetic considerationPatient positioning and anaesthetic consideration
Patient positioning and anaesthetic consideration
 
Supraglottic Airway Device
Supraglottic Airway DeviceSupraglottic Airway Device
Supraglottic Airway Device
 

Viewers also liked

Emt management of airway and breathing
Emt management of airway and breathingEmt management of airway and breathing
Emt management of airway and breathingDang Thanh Tuan
 
13236530 Anesthesia Pharmacology
13236530 Anesthesia Pharmacology13236530 Anesthesia Pharmacology
13236530 Anesthesia PharmacologyTsega Tilahun
 
Tracheostomy and Cricothyroidotomy
Tracheostomy and CricothyroidotomyTracheostomy and Cricothyroidotomy
Tracheostomy and Cricothyroidotomyalok thakur
 
Scavenging system in operating room
Scavenging system in operating roomScavenging system in operating room
Scavenging system in operating roomDr Kumar
 
Airway obstruction and management
Airway obstruction and managementAirway obstruction and management
Airway obstruction and managementShahab Riaz
 
hypertension anesthesia, general management. antihypertensive pharmacology
hypertension anesthesia, general management. antihypertensive pharmacologyhypertension anesthesia, general management. antihypertensive pharmacology
hypertension anesthesia, general management. antihypertensive pharmacologyAbayneh Belihun
 
Anaesthesia machine
Anaesthesia machineAnaesthesia machine
Anaesthesia machineimran80
 

Viewers also liked (10)

Emt management of airway and breathing
Emt management of airway and breathingEmt management of airway and breathing
Emt management of airway and breathing
 
Muscle relaxant
Muscle relaxantMuscle relaxant
Muscle relaxant
 
13236530 Anesthesia Pharmacology
13236530 Anesthesia Pharmacology13236530 Anesthesia Pharmacology
13236530 Anesthesia Pharmacology
 
Tracheostomy and Cricothyroidotomy
Tracheostomy and CricothyroidotomyTracheostomy and Cricothyroidotomy
Tracheostomy and Cricothyroidotomy
 
Scavenging system in operating room
Scavenging system in operating roomScavenging system in operating room
Scavenging system in operating room
 
Airway obstruction and management
Airway obstruction and managementAirway obstruction and management
Airway obstruction and management
 
Breathing systems (2)
Breathing systems (2)Breathing systems (2)
Breathing systems (2)
 
hypertension anesthesia, general management. antihypertensive pharmacology
hypertension anesthesia, general management. antihypertensive pharmacologyhypertension anesthesia, general management. antihypertensive pharmacology
hypertension anesthesia, general management. antihypertensive pharmacology
 
Anaesthesia machine
Anaesthesia machineAnaesthesia machine
Anaesthesia machine
 
Airway Management
Airway ManagementAirway Management
Airway Management
 

Similar to Face masks, laryngeal tube, airways yuvaraj

#Laryngoscopes face mask-airway &amp; endotracheal tubes
#Laryngoscopes face mask-airway &amp; endotracheal tubes#Laryngoscopes face mask-airway &amp; endotracheal tubes
#Laryngoscopes face mask-airway &amp; endotracheal tubesNisar Arain
 
FACE MASK AND AIRWAY.pptx
FACE MASK AND AIRWAY.pptxFACE MASK AND AIRWAY.pptx
FACE MASK AND AIRWAY.pptxPrarthana83
 
airwayequipment2-210902170038 2.pdf
airwayequipment2-210902170038 2.pdfairwayequipment2-210902170038 2.pdf
airwayequipment2-210902170038 2.pdfMonishaSekaran1
 
BASIC AIRWAY EQUIPMENTS.pptx
BASIC AIRWAY EQUIPMENTS.pptxBASIC AIRWAY EQUIPMENTS.pptx
BASIC AIRWAY EQUIPMENTS.pptxDhanushHarikumar
 
Oropharyngeal airway and nasopharyngeal airway_114337 (1).pptx
Oropharyngeal airway and nasopharyngeal airway_114337 (1).pptxOropharyngeal airway and nasopharyngeal airway_114337 (1).pptx
Oropharyngeal airway and nasopharyngeal airway_114337 (1).pptxSuchismita Pal
 
facemaskairways-150521183800-lva1-app6891.pdf
facemaskairways-150521183800-lva1-app6891.pdffacemaskairways-150521183800-lva1-app6891.pdf
facemaskairways-150521183800-lva1-app6891.pdfRakshatNayak1
 
Airway management
Airway managementAirway management
Airway managementsob7anallah
 
8-Intubation and tfffffffracheostomy.pdf
8-Intubation and tfffffffracheostomy.pdf8-Intubation and tfffffffracheostomy.pdf
8-Intubation and tfffffffracheostomy.pdfMosaHasen
 
Airway management part 3.
Airway management part 3.Airway management part 3.
Airway management part 3.Nisar Arain
 
airway management part-3.-Anesthesia
airway management part-3.-Anesthesiaairway management part-3.-Anesthesia
airway management part-3.-AnesthesiaNISAR ARAIN
 
Techniques of mask ventilation
Techniques of mask ventilation Techniques of mask ventilation
Techniques of mask ventilation Tess Jose
 
Guideline for airway management3
Guideline for airway management3Guideline for airway management3
Guideline for airway management3Micah Iduitua
 
supraglotticairwaydevice-150407110752-conversion-gate01.pptx
supraglotticairwaydevice-150407110752-conversion-gate01.pptxsupraglotticairwaydevice-150407110752-conversion-gate01.pptx
supraglotticairwaydevice-150407110752-conversion-gate01.pptxMSrujanaDevi
 

Similar to Face masks, laryngeal tube, airways yuvaraj (20)

#Laryngoscopes face mask-airway &amp; endotracheal tubes
#Laryngoscopes face mask-airway &amp; endotracheal tubes#Laryngoscopes face mask-airway &amp; endotracheal tubes
#Laryngoscopes face mask-airway &amp; endotracheal tubes
 
FACE MASK AND AIRWAY.pptx
FACE MASK AND AIRWAY.pptxFACE MASK AND AIRWAY.pptx
FACE MASK AND AIRWAY.pptx
 
airwayequipment2-210902170038 2.pdf
airwayequipment2-210902170038 2.pdfairwayequipment2-210902170038 2.pdf
airwayequipment2-210902170038 2.pdf
 
Airway equipment
Airway equipment Airway equipment
Airway equipment
 
BASIC AIRWAY EQUIPMENTS.pptx
BASIC AIRWAY EQUIPMENTS.pptxBASIC AIRWAY EQUIPMENTS.pptx
BASIC AIRWAY EQUIPMENTS.pptx
 
Face mask, airways,et tubes and laryngoscopes
Face mask, airways,et tubes and laryngoscopesFace mask, airways,et tubes and laryngoscopes
Face mask, airways,et tubes and laryngoscopes
 
Difficult airway
Difficult airwayDifficult airway
Difficult airway
 
Difficult airway : Made easy
Difficult airway : Made easy Difficult airway : Made easy
Difficult airway : Made easy
 
airway management
airway managementairway management
airway management
 
Oropharyngeal airway and nasopharyngeal airway_114337 (1).pptx
Oropharyngeal airway and nasopharyngeal airway_114337 (1).pptxOropharyngeal airway and nasopharyngeal airway_114337 (1).pptx
Oropharyngeal airway and nasopharyngeal airway_114337 (1).pptx
 
facemaskairways-150521183800-lva1-app6891.pdf
facemaskairways-150521183800-lva1-app6891.pdffacemaskairways-150521183800-lva1-app6891.pdf
facemaskairways-150521183800-lva1-app6891.pdf
 
Pediatric airway management
Pediatric airway managementPediatric airway management
Pediatric airway management
 
AIRWAY ADJUNCT
AIRWAY ADJUNCTAIRWAY ADJUNCT
AIRWAY ADJUNCT
 
Airway management
Airway managementAirway management
Airway management
 
8-Intubation and tfffffffracheostomy.pdf
8-Intubation and tfffffffracheostomy.pdf8-Intubation and tfffffffracheostomy.pdf
8-Intubation and tfffffffracheostomy.pdf
 
Airway management part 3.
Airway management part 3.Airway management part 3.
Airway management part 3.
 
airway management part-3.-Anesthesia
airway management part-3.-Anesthesiaairway management part-3.-Anesthesia
airway management part-3.-Anesthesia
 
Techniques of mask ventilation
Techniques of mask ventilation Techniques of mask ventilation
Techniques of mask ventilation
 
Guideline for airway management3
Guideline for airway management3Guideline for airway management3
Guideline for airway management3
 
supraglotticairwaydevice-150407110752-conversion-gate01.pptx
supraglotticairwaydevice-150407110752-conversion-gate01.pptxsupraglotticairwaydevice-150407110752-conversion-gate01.pptx
supraglotticairwaydevice-150407110752-conversion-gate01.pptx
 

More from havalprit

Anaesthetic mgt for pt with hyperthyroidism pritam
Anaesthetic mgt for pt with hyperthyroidism  pritamAnaesthetic mgt for pt with hyperthyroidism  pritam
Anaesthetic mgt for pt with hyperthyroidism pritamhavalprit
 
Anatomy & physiology of neuromuscular junction & monitoring
Anatomy & physiology of neuromuscular junction & monitoringAnatomy & physiology of neuromuscular junction & monitoring
Anatomy & physiology of neuromuscular junction & monitoringhavalprit
 
Sterilization of ot & ot equipments pritam
Sterilization of ot & ot equipments  pritamSterilization of ot & ot equipments  pritam
Sterilization of ot & ot equipments pritamhavalprit
 
Benzodiazipines
Benzodiazipines  Benzodiazipines
Benzodiazipines havalprit
 
Breathing systems open circuit- shoeib
Breathing systems  open circuit- shoeibBreathing systems  open circuit- shoeib
Breathing systems open circuit- shoeibhavalprit
 
Physiology of ANS
Physiology of ANSPhysiology of ANS
Physiology of ANShavalprit
 

More from havalprit (6)

Anaesthetic mgt for pt with hyperthyroidism pritam
Anaesthetic mgt for pt with hyperthyroidism  pritamAnaesthetic mgt for pt with hyperthyroidism  pritam
Anaesthetic mgt for pt with hyperthyroidism pritam
 
Anatomy & physiology of neuromuscular junction & monitoring
Anatomy & physiology of neuromuscular junction & monitoringAnatomy & physiology of neuromuscular junction & monitoring
Anatomy & physiology of neuromuscular junction & monitoring
 
Sterilization of ot & ot equipments pritam
Sterilization of ot & ot equipments  pritamSterilization of ot & ot equipments  pritam
Sterilization of ot & ot equipments pritam
 
Benzodiazipines
Benzodiazipines  Benzodiazipines
Benzodiazipines
 
Breathing systems open circuit- shoeib
Breathing systems  open circuit- shoeibBreathing systems  open circuit- shoeib
Breathing systems open circuit- shoeib
 
Physiology of ANS
Physiology of ANSPhysiology of ANS
Physiology of ANS
 

Recently uploaded

POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxSayali Powar
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxpboyjonauth
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityGeoBlogs
 
The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13Steve Thomason
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxheathfieldcps1
 
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptxContemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptxRoyAbrique
 
Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfciinovamais
 
Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...
Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...
Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...RKavithamani
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdfQucHHunhnh
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docxPoojaSen20
 
Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Celine George
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformChameera Dedduwage
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactdawncurless
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationnomboosow
 
CARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxCARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxGaneshChakor2
 
Web & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdfWeb & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdfJayanti Pande
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Sapana Sha
 
Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionSafetyChain Software
 

Recently uploaded (20)

POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptx
 
Staff of Color (SOC) Retention Efforts DDSD
Staff of Color (SOC) Retention Efforts DDSDStaff of Color (SOC) Retention Efforts DDSD
Staff of Color (SOC) Retention Efforts DDSD
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activity
 
The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptx
 
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptxContemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
 
Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdf
 
Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...
Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...
Privatization and Disinvestment - Meaning, Objectives, Advantages and Disadva...
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docx
 
Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy Reform
 
TataKelola dan KamSiber Kecerdasan Buatan v022.pdf
TataKelola dan KamSiber Kecerdasan Buatan v022.pdfTataKelola dan KamSiber Kecerdasan Buatan v022.pdf
TataKelola dan KamSiber Kecerdasan Buatan v022.pdf
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impact
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communication
 
CARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxCARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptx
 
Web & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdfWeb & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdf
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
 
Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory Inspection
 

Face masks, laryngeal tube, airways yuvaraj

  • 1. J.J.M. MEDICAL COLLEGE, DAVANGERE DEPARTMENT OF ANAESTHESIA SEMINAR ON Face mask ,airway, laryngoscope and endotracheal tube Chair person: Presented by: Dr.Nalinakshamma.SDr.YuvarajShastri MD.DA., PG in anaesthesia Professor.
  • 3. Introduction It is the device which allows administration of gases to the patient from breathing system without introducing any apparatus to the patients mouth.
  • 4. Description A face mask can be made up of black rubber, clear plastics, elastomeric material or combination of these. Parts of the face mask: Body: constitutes the main part of the mask Transparent body allows observation of moisture, vomitus , secretions etc .
  • 5. Seal : Comes in contact with the face.Two types are available Pad or cushion – inflated with air Flap – flexible extension of the body Connector ( orifice/ collar ) : Opposite to the seal Thickened fitting of 22 mm ID Ring with hooks helps in strapping the mask
  • 6. Specific masks : 1. Anatomical mask : Can be moulded to conform to the anatomy of face . Has slightly malleable rubber body, a sharp notch for the nose and a curved chin section.
  • 7. 2. Rendell-baker-soucek(RBS) mask Designed for paediatric patients < than 10 yrs It has triangular body and low dead space Used in tracheostomy and acromegaly patients
  • 8.
  • 9. 3. Endoscopic mask : Designed to allow mask ventilation during endoscopy It has port or diaphragm in the body to allow fibroscope insertion
  • 10. 4. Scented mask : Scent incorporated into the mask by manufacturer or anaesthesia provider Added for better acceptability and pleasant experience during induction Disadvantage- ethyl alcohol in some flavors may affect accuracy of gas monitors.
  • 11. Techniques of use: The face mask should form tight seal on the pts face while fitting comfortably in the user`s hand. The smallest mask is most desirable because it will cause least increase in dead space, easy to hold & less likely to result in pressure on eyes. There are several methods
  • 12. One Hand Method - the thumb & index finger of left hand are placed on mask body on opposite sides of connector push downward to prevent leak. The remaining 3 fingers are placed on the mandible such that middle finger is applied to the mentum, ring finger on body of mandible & little finger at angle of mandible to give jaw thrust anteriorly
  • 13.
  • 14. Two Handed Method – As it requires both hands, a 2nd person is necessary for assisted or controlled ventilation. Here thumbs are placed on either side of body of masks, index fingers are placed under the angles of jaw, mandible is lifted & head is extended. If a leak is present, downward pressure on mask can be increased by anesthesiologist’s chin on the mask elbow
  • 15.
  • 16. Two Handed Jaw Thrust – 1 person stands at head end of pt & performs jaw thrust with his left hand at angle of left mandible while his right hand compresses the reservoir bag. The 2nd person stands at pts shoulder facing 1st person. This persons Rt hand covers the Lt hand of the 1st person & the Lt hand achieves Rt sided Jaw thrust & mask seal.
  • 17. Claw Hand Technique – It is useful for children undergoing short duration procedures. The Anesthesiologists stands at the side of bed facing the child. The face mask is applied to face by using the Rt hand with the palmar surface facing upwards. The ring & middle finger are placed under the angle of jaw & the index finger & thumb encircle the body of mask.
  • 18. Dead space in face masks: Face mask and its adaptor increase dead space and it may contribute 30% or more of tidal volume in neonates and infants. It can be reduced by: a) using smaller size mask. b) increasing pressure on mask. c) blowing a jet of fresh gas into the mask. d) changing the volume of the seal cushion
  • 19. Advantages Lower incidence of sore throat requires less anaesthetic depth than tracheal tube or supraglottic device. No need of muscle relaxants. The face mask may be the most cost efficient method for short cases.
  • 20. Disadvantages Anesthesiologist`s hands are tied up higher fresh gas flows are often needed. During remote anesthesia, airway access is difficult ( CT & MRI). Often more episodes of oxygen desaturation & require more intraoperative airway manipulations
  • 21. Complications Skin problems- dermatitis, pressure necrosis. Nerve injury. Eye injury – conjunctivalchemosis, eyelid edema & corneal injuries. Gastric Inflation Latex allergy Lack of co-relation between arterial & end tidal CO2. Environmental Pollution with anesthetic gases Jaw Pain & User fatigue.
  • 23. Introduction: A fundamental responsibility of anaesthesia providers is to maintain a patent airway. The airway passage has a rigid posterior wall and a collapsible anterior wall consisting of the tongue and epiglottis. Under anaesthesia the tongue & epiglottis falls back into the posterior pharynx occluding the airway. The purpose of airway is to lift the tongue & epiglottis away from the posterior pharyngeal wall & maintain a patent airway.
  • 24.
  • 25. Terminology : Artificial airway - any device that aims to maintain oral or nasal air passages. It may be Simple supraglottic devicesuch as oropharyngeal or nasopharyngeal airways. These may not be sufficient to maintain the patency of airway on their own & may require pts jaw to be supported as well. Augmented supraglottic devicesuch as LMA & airway management device Infraglottic devicessuch as Endotrachealtubes,tracheostomy tubes, jet ventilation catheters.
  • 26. Oropharyngeal Airways Description It extends from lips to pharynx, fitting between tongue & posterior pharyngeal wall. Made up of elastomeric or plastic materials. Parts are Flange it is at buccal end to prevent it from moving deeper into mouth & may also serve to fix airway in place. Bite Portion it is straight & fits between teeth & gums.. Curved portion extends backwards to correspond the shape of tongue & palate.
  • 27. The American National Standard specifies that the size of oral airways be designated by a no. i.e the length in cms.
  • 28. SPECIFIC AIRWAYS Guedel Airway Most frequently used airway & has large flange & reinforced bite portion with tubular channel for air exchange & suctioning.
  • 29. Cuffed Oro-Pharyngeal Airway It is Guedel`s Airway with an inflatable cuff designed to seal the oropharynx. It has an integral bite block & a 15mm connector for attachment of the breathing circuit. The cuff is inflated with air to displace the base of tongue & form a low pressure seal with the pharynx & provide an open airway.
  • 30. Patil-Syracuse Endoscopic Airway It was designed to aid fiber-optic intubation. It is made of aluminium. It has lateral channels & a central groove on the lingual surface to allow passage of fiberscope. A slit in distal end allows fiberscope to be manipulated in antero-posterior direction but limits lateral movements.
  • 31. Berman Intubating Airway It is tubular along its entire length. It is open on 1 side so that it can be split & removed from around a tracheal tube. It can be used as an oral airway or as an aid to fiberoptic or blind oro-tracheal intubation
  • 32. Williams Airway Intubator Designed for blind tracheal intubation & can also be used for fiberoptic intubation or as an oral airway. It is available in 2 sizes #9 & #10 which will admit upto 8 & 8.5 mm tracheal tube respectively. The proximal half is cylindrical while distal half is open on lingual surface.
  • 33. OvassapianFiberopticIntubating Airway Designed for fiberoptic intubation. Has a flat lingual surface which gradually widens at distal end & 2 vertical sidewalls at the buccal end. Between the sidewalls are a pair of guide walls that curve towards each other which are flexible & permit removal of airways around the tracheal tube. The proximal half is tubular & acts as bite block. The distal half is opened posteriorly & it can accommodate tracheal tube upto 9mm id
  • 34. . METHODS OF INSERTION Pharyngeal & laryngeal reflexes should be depressed before an airway is inserted to avoid coughing & laryngospasm. Selecting the correct size is important. Correct size is estimated by holding the airway next to pts mouth & the tip should be at the angle of mandible. The best criteria for proper size & position is unobstructed gas exchange
  • 35. Oral airway may be inserted in 2 ways The jaw opened with Lt hand. The airway is inserted with its concave side towards the upper lip & when the junction of bite portion & curved section is near the incisors, the airway is rotated 180° & slipped behind the tongue in the final position .
  • 36. A tongue blade is used to push forward and depress the tongue & the airway is inserted with concave side towards the tongue & is advanced.
  • 37. OTHER USES May be used to prevent pt from biting & occluding ETT. Protect the tongue from biting To facilitate suctioning To obtain better mask fit.
  • 38. NASOPHARYNGEAL AIRWAY (nasal trumpet/ nasal airway) It extends from nose to pharynx, the pharyngeal end should be below base of tongue but above the epiglottis. A nasal airway is better tolerated than oral airway if the pt has intact airway reflexes. Description It resembles a shortened tracheal tube with a flange at the outer end to prevent it from completely passing into the nares. It is made up of plastic or rubber & the size is designated by the inner diameter in mm
  • 40. specific types Linder Nasopharyngeal Airway It is plastic with large flange & flat distal end and is supplied with introducer which has balloon on its tip. Before insertion, the introducer is inserted into the airway until the tip of balloon is just past the end. Air is injected until the balloon tip is inflated to approx outer diameter of tube. The complete assembly is lubricated & inserted through the nostril. After it is in place, the balloon is deflated & introducer is removed.
  • 41. Cuffed Nasopharyngeal Airway It is similar to a short, cuffed tracheal tube. It is inserted through the nose into the pharynx; cuff inflated & then is pulled back until resistance is felt. Binasal Airway It consists of 2 nasal airways joined together by an adaptor for attachment to the breathing system. Can be used to administer anesthesia
  • 42. INSERTION The diameter of nasal airway should be the same as needed to insert the tracheal tube (0.5-1.0mm smaller than oral tracheal tube). Before insertion it should be lubricated thoroughly along its entire length. The airway is held with the bevel against septum & gently advanced posteriorly while being rotated back & forth.
  • 43. COMPLICATIONS Airway obstruction Epistaxis Ulceration & Necrosis Dental Damage CNS trauma Laryngospasm & Coughing. Aspiration or Swallowing of part or all of the airway. Latex Allergy Gastric distension.  
  • 45. Introduction A laryngoscope is an instrument used to view larynx and adjacent structures, most commonly for introducing tube into the trachea Laryngoscopes can be considered under two broad headings. Retractor type like the Macintosh laryngoscope. Fibreoptic Laryngoscope Two types : Rigid fibreoptic laryngoscope Flexible fibreoptic laryngoscope.
  • 46. History In 1885, Alfred Kirstein first used esophageal scope to visualize the larynx. In 1907, Chevailior Jackson introduced the separable laryngoscope with a U handle. In 1913, Janeway introduced the first fashioned scope specially for anesthetist. It was the first to incorporate battery in the handle
  • 47. RIGID LARYNGOSCOPES: These are manufactured either as single piece or separate detachable blade and handle. For detachable handle & blade the light source is energized when blade & handle are locked in operating position. A single piece laryngoscope has a switch on handle that controls power to lamp. Rigid Laryngoscope has 2 parts 1. Handle 2. Blade .
  • 48. 1. Handle: The handle is the part that is held in the hand during use. It provides the power source for the light. Most often this is from disposable batteries. Fibreoptic illuminated laryngoscope may use a remote electrically operated light source. The handle is fitted with a hinge pin that fits a slot on the base of the blade..
  • 49. Handles are available in variable sizes & have rough surface for improved grip.
  • 50. Although most blades form right angle with the handle when ready to use. The angle may also be acute or obtuse. An adapter may be fitted between the handle and the blade to allow angled to be altered. Howland lock is such an example. The patil-syracusehandle can be positioned and locked in four different positions (45°, 90°, 135° and 180°).
  • 52. 2. Blade The blade is a component that is inserted into the mouth. When a blade is available in more than one size, blades are numbered, with the number increasing with size.
  • 53. The parts of the blade include base heel spatula/tongue flange web tip light source.
  • 54. Types of Blades There are several types of blades which may be advantageous in particular situations. Macintosh Blade The Macintosh blade is one of the most popular. The tongue has a smooth, gentle curve that extends from the base to the tip. In cross-section, the tongue, web. and flange form a reverse 'Z'. Cervical spine movement is greater compared to the Miller blade.
  • 55. Left handed Macintosh Blade The left handed Macintosh blade has the flange on the opposite side from the usual Macintosh blade. This blade may be useful for the abnormalities of right side of the face or oropharynx, left handed persons, intubating in the right lateral position, and positioning a tracheal tube directly on the left side of the mouth.
  • 56. Improved Vision Macintosh Blade The Improved Vision (IV) Macintosh blade is similar to the standard version except that the mid portion of the tongue is concave to allow greater visualization of the larynx
  • 57. Polio Blade The blade is offset from the handle at an obtuse angle to allow intubation of patients in iron lung respirators or body jackets Patients with obesity, breast hypertrophy, kyphosis with severe barrel chest deformity, short neck, or restricted neck mobility. Disadvantages of this blade are that little force can beapplied and control is minimal
  • 58. Oxiport Macintosh (Mac/port) The Oxiport Macintosh blade a, conventional Macintosh blade with a tube added to deliver oxygen
  • 59. Tull Macintosh The Tull (suction) blade is a modified Macintosh that has a suction port near the tip. The suction channel extends next to the handle and has a finger controlled valves so that suction can be controlled by the laryngoscopist.
  • 60. Fink Blade The Fink blade is another modification of the Macintosh. The tongue is wider and has a sharper curve at the distal end. The height of the flange is reduced, especially at the proximal end. The light bulb is placed farther forward than on the Macintosh.
  • 61. Bizarri-Guiffrida Blade The Bizarri-Guiffrida blade is a modified Macintosh. The flange is removed, except for a small part that encases the light bulb. This was made to limit damage to the upper teeth. The blade is useful for patients with a limited mouth opening, prominent incisors, receding mandible, short & thick neck or anterior larynx
  • 62. Miller Blade The tongue is straight with a slight upward curve near the tip. In cross-section the flange, web, and tongue form a C with the top fattened. The lamp may be either on the right or left side of the blade.
  • 63. Oxiport Miller Blade The Oxiport Miller (also called Miller/port, oxyscope) blade has a built-in tube that allows delivery of oxygen or other gases during intubation. The tube also may be used for suction. Insufflation of oxygen during intubation using this blade has been found to decrease oxygen desaturation in spontaneously breathing anesthetized patients.
  • 64. Tull Miller Blade Tull (suction) Miller blade is a standard Miller blade with a suction tube whose port ends near the tip of the blade. Near the handle is a finger-controlled port that allows control of suction with a finger.
  • 65. Mathews Blade The Mathews blade is a straight blade with a wide and flattened petalloid configuration tip. It is designed for difficult nasotracheal intubations.
  • 66. Alberts Blade It has a cut-away flange to increase the visibility. There is recess to facilitate tracheal tube insertion. The blade forms a 67° angle with the handle. It is used for pediatric pt.
  • 67. Double Angle Blade The spatula of double angle blade has 2 angulations 20° & 30°, to improve lifting of the epiglottis. The flange has been eliminated. The bulb is located at left edge of the blade between the 2 curvatures. The blade may be useful for the pt with anterior larynx.
  • 68. Flexible tip blade It has a hinged tip that is controlled by lever attached to the proximal end of the blade When the lever is pushed towards the handle,the tip of the blade is flexed. Eg: Mc-Coy, flipper,flex tip etc. It may improve the chances of successful intubation by elevating the epiglottis particularly in case of difficult intubation. Less force and less stress response.
  • 70. Techniques of use positioning the head : The head should be positioned so that the passage-way to the larynx is brought into a straight line for the best possible view of the vocal cords. The optimal position for most patients is flexion of 35° of the lower cervical spine and extension of the head of 85-90° at the atlanto-occipital level, the so-called sniffing position. In children, it may be unnecessary to flex the lower cervical vertebrae, and in neonates it may be necessary to elevate the shoulders because the head is relatively larger.
  • 71. The laryngoscope handle is held in the left hand. The fingers of the right hand are used to open the mouth and spread the lips apart. The blade is inserted at the right side of the mouth. This reduces the likelihood of incisor teeth damage and helps push the tongue to the left. The blade is advanced on the side of the tongue toward the right tonsillarfossa, so that the tongue lies on the left side of the blade. When the right tonsillarfossa is visualized, the tip of the blade is moved toward the midline. The blade is then advanced behind the base of the tongue, elevating it, until the epiglottis comes into view.
  • 72. There are two methods for elevating the epiglottis, depending on whether a straight or curved blade is being used. Straight Blade Technique The blade is made to scoop under the epiglottis and lift it anteriorly. The vocal cords should be identified. If the blade is advanced too far, it will result in elevation of the larynx as a whole rather than exposure of the vocal cords. The straight blade can also be inserted into the vallecula and used in the same manner as a curved blade.
  • 73. Curved Blade After the epiglottis is seen, the blade is advanced until the tip fits into the valleculla. Traction is then applied along the handle, at right angles to the blade to carry the base of the tongue and the epiglottis forward. The glottis should come into view
  • 74.
  • 75. RIGID FIBEROPTIC LARYNGOSCOPES Bullard laryngoscope Description It has a rigid metal blade specially shaped to follow the contour of the oropharynx. Fibreoptic bundles for illumination & operatory viewing are housed in a sheath on the posterior aspect of blade. A viewing arm with eye-piece extends at a 45°angle from the handle. A video camera can be attached to eyepiece for remote viewing. A working channel extends from the scope body to the point where the light bundles end at the tip. It can be used for suction, oxygen insufflations, administration of L.A/ Saline, or jet ventilation catheter.
  • 76. 3 sizes are available : Pediatric Pediatric long – for babies upto 8-10yrs of age. Adult version – for children more than 10yrs & adults. Advantages : It causes less cervical spine movement than conventional laryngoscopy. Requires mouth opening of only 7mm. Rapidity of intubation Low risk of failed intubation or trauma to lips or teeth.
  • 77. Disadvantages: Requires experience & Maintainence of skills & is somewhat expensive. Intubation with ETT >7.5mm may be more difficult. Certain ETT & Double lumen tubes will not fit the stylet
  • 78. WuScope Description : It combines a rigid, tubular blade & a flexible fiberscope. Flexible Fiberscope portion. The fiberscope has short light & image transmitting fibreoptic bundles & tip deflection control. Blade portion It has 3 detachable metal parts - handle, main blade & bivalve element.
  • 79. Handle- cone shaped tube that receives the fiberscope at the top & connects to the main blade at the base. The handle to blade angle is 110°. Main blade & bivalve element are anatomically shaped. When positioned together, they form 2 passage ways- a larger 1 for suction catheter or ETT & a smaller 1 for fiberscope. An oxygen channel is alongside the slot for fiberscope. Different sizes of blades & bivalve element can be used with the handle. The adult blade can accommodate ETT upto 8.5mm
  • 80.
  • 81. Advantages Can be used successfully to place both tracheal & double lumen bronchial tubes in difficult-to-intubate pts. No forceps or stylet is needed so risk of airway injury is low. Suctioning & oxygen administration can done simultaneously. Unlike flexible fibreoptic endoscopy, 1 can view ETT passing through glottis into trachea. There is no need for head extension or tongue lifting.
  • 82. Disadvantages Requires experience or Maintainence of skills & high initial cost. Time required to assemble or disassemble the device is more. Application of cricoids pressure decreases the ease of intubation while using this device.
  • 83. UpsherScope Description It consists of C-shaped metal blade, shaped to approximate curve of oropharynx. The distal part has an upward curve. To the lt are 2 tubes that carry fibreoptic bundles. Proximally the viewing bundle terminates in the eye piece while the light bundle makes contact with the light source at the handle.. It is presently available only in adult size.
  • 84. Advantages It can be used with all size of adult ETT. Useful to intubate pts with difficult airways in a reasonable time. Disadvantages Not suitable for naso-tracheal intubation. In routine intubation this scope has demonstrated no advantages over the conventional laryngoscopes
  • 85. VIDEO LARYNGOSCOPE It can be created by attaching video system to a flexible laryngoscope or an optical stylet. It has many advantages – The displayed anatomy is magnified & a larger viewing angle is provided. In addition to allowing laryngoscopy & intubation to be visualized, it can be used to observe vocal cord movements after thyroid surgery, verify tracheal tube position & aid in tracheal tube exchange. Results in less neck movement than conventional laryngoscopy. By projecting the image it makes a good teaching tool Limitations of these device is the need for a video endoscopy monitoring system.
  • 86. VIDEO MACINTOSH INTUBATING LARYNGOSCOPE It has macintosh blade attached to the handle. The image- light bundle is threaded through a small guide in the blade & advanced 2/3 of the length of the blade. Provides better view than traditional macintosh laryngoscope.
  • 87. GLIDE SCOPE Description : It has a miniature digital camera underside of a plastic blade. A light emitting device( LED) mounted beside the camera provides illumination. Blade has a 60° bend at the midpoint The Glide Scope is available in adult & pediatric size. Studies shows this scope yields a comparable or superior glottis view compared to direct laryngoscopy. It causes less cervical movements than macintosh blade
  • 88. FLEXIBLE FIBEROPTIC LARYNGOSCOPE Introduction: The 1st use of flexible fibreoptic technology in the airway management can be credited to Dr P Murphy, who in 1967 invented Choledochoscope for intubation of trachea. The flexibility of these devices means that they can be made to follow virtually any anatomical space to return an image of the objective. The technique of flexible fibreoptic intubation has become a gold standard for management of difficult laryngoscopy. This has tended to create the impression that the technique is solution to all difficult airways, but this is patently not so.
  • 89. Principles & Design The pathway through which the illumination & the image pass consists of thousands of very fine glass fibers, each typically of 10µm in diameter. Each fiber consists of a central glass core surrounded by a thin cladding of another type of glass with different refractive index. As a result of difference in refractive indices, light entering the glass fiber undergoes total internal reflection along the length of the fiber to emerge at the other end. For image transmission, the arrangement of fibers relative to one another must be identical at either end of the bundle, as each fiber carries tiny portion of the overall image. This is called a COHERENT BUNDLE.
  • 90.
  • 91. Parts It is composed of several parts, a light source, handle & flexible insertion portion. The handle is the part to be held in hand during use. It includes the eyepiece, focusing ring, working channel port & the tip control lever. The insertion tube carries 2 light bundles 1 image bundle 1 working or biopsy channel 2 angulation wires, which control the more flexible tip of device
  • 92. These are held together with a stainless steel spiral wrap followed by a stainless steel braid & covered by waterproof material, to give a rigid cross section while allowing overall flexibility. The fiberscope is axially rigid to twisting forces thus rotation of the control handle results in similar rotation of the tip. The fiberscope uses a powerful external cold light source so that the tissues are not damaged by radiant heat.
  • 93. Usage The intubatingfiberscopes are available with insertion tubes ranging in size from 2.5mm ext diameter to over 6mm with proportionately larger working channels. A device with ext diameter of 3.5mm is optimal for use in adults. The advent of the miniature video camera has revolutionized fibreoptic endoscopy.
  • 94. Fibreoptic Intubation It can be performed via oral or nasal route. The fiberscope is inserted & advanced behind the tongue & into the larynx. Once in the trachea, a tracheal tube which has been previously loaded onto the fiberscope is advanced off the scope into the trachea & then the fiberscope is removed. Oral intubation is considered more difficult than nasal intubation
  • 95. Advantages Reliable approach to the difficult airway management. Facility to record images for review & documentation. Improvements in teaching techniques. Disadvantages More expensive & fragile & difficult to use than rigid laryngoscope. Requires more time than rigid laryngoscopy. Requires considerable experience & skill Maintainence Laryngeal trauma may occur.
  • 96. Complications of laryngoscopy 1. Dental injury 2. damage to soft tissue and nerves 3. Injury to cervical spinal cord 4. Circulatory changes 5. Swallowing or aspiration of foreign body. 6. Shock or Burns 7. Laryngoscope malfunctions 8. Disease transmission 9. TMJ Dislocation.
  • 98. HISTORY In 1667 Robert Hook kept a dog alive for over an hour by ventilating its lungs with a pair of bellows tied into the trachea. In 1871, Friedrich Trendelenburg developed a cuffed catheter for insertion through a tracheostomy to prevent soiling of the lungs during operation of the upper airway. In 1878, the Glasgow surgeon William MacEven placed a metal tube by manual palpation through the mouth into the trachea & administered chloroform anaesthesia. In 1950s, the use of cuffed ETT became standard anesthetic practice.
  • 99. DESCRIPTION: An endotracheal tube is one through which anesthetic gases and respiratory gases are conveyed into and out of the trachea. It has tracheal & machine end The bevel is defined as the slanted part of the tube at the tracheal end. When, an opening in the tube is present on the opposite side of the bevel, it is designated as Murphy's tip endotracheal tube.
  • 100. REQUIREMENTS OF IDEAL ET TUBE 1) Inertness 2) Smoothness of outer surface to avoid damage to mucosa 3) Inner surface should be smoothed and non-wettable to prevent building of secretions. 4) Non-inflammable 5) Transparent 6) Easily sterilized 7) Non kinking
  • 101. 8) Sufficient strength to allow thin wall construction 9) Thermoplasticity to confirm to anatomic passage and to be self centering within the trachea. 10) Non reactive with lubricants or anesthetic agents 11) Latex free 12) Non injurious catheter tip Currently used tubes are manufactured from synthetic rubber, plastic materials and silicone.
  • 102. GENERAL PRINCIPLES RESISTANCE AND WORK OF BREATHING A tracheal tube places a mechanical burden on spontaneously breathing patient. It is a source of more resistance and is an important factor in determining the work of breathing. The factors determining the resistance include: 1) Internal diameter: The tube with thick wall decreases the ID and thereby increases the resistance and vice-versa. 2) Length: Decreasing the length of the tube decreases the resistance. 3) Configuration: Abrupt change in the diameter and direction increases the resistance. Gentle curve connectors offer less resistance than right-angled ones as there will be increased resistance because of turbulent flow of gases.
  • 103. DEAD SPACE The volume of tracheal tube and connector is usually less than that of the natural passage. Dead space is normally reduced by intubation. In pediatric patients long tubes and connectors may increase the dead space considerably.
  • 104. STANDARD MARKING OF ETT The markings are situated on the bevel side above the cuff & are read from pt end to machine end Type of the tube: Oral or nasal or oral/nasal Size: ID in mm External diameter may also be indicated. Manufacturer's name or trade mark
  • 105. Tube has Graduated markings, showing the distance in cms from the patient end. Precautions are usually noted: Disposable/Do Not Reuse Implantation tests (IT) or Z-79 indicating the tube has been tested for tissue toxicity & accomplish ANSI standard. Opaque lines may also be included at the patient end or along full length.
  • 106. CUFF SYSTEM A Cuff system consists of the cuff & inflation system. The purpose of cuff system is to provide a seal between tube & tracheal wall to prevent passage of pharyngeal contents into the trachea & ensure no gas leaks past the cuff. The cuff also serves to center the tube in trachea.
  • 107.   INFLATION SYSTEM 1) Inflation valve: When a syringe tip is inserted, a plunger is displaced from its seat & gas can be injected into the cuff. Upon removal of the syringe the valve seals and gas cannot escape. 2)Pilot balloon: Its function is to give an indication of inflation or deflation of the cuff and a rough idea of the cuff pressure.
  • 108. 3) External inflation tube: The standard specifies , a)The external diameter should not exceed 2.5mm b) The inflation tube should be attached to the ETT at asmall angle. c) The tube should extend at least 3cm beyond the machine end of the ETT before a pilot balloon or inflation valve is incorporated. 4) Inflation lumen: This connects the inflation tube to the cuff. It is located within the wall of the tracheal tube.
  • 109. CUFF: The cuff is a inflatable sleeve near the patient end of ETT. The cuff material should be strong and tear resistant but thin, soft and pliable. Cuffs are usually made of the same material as the ETT.
  • 110. CUFF PRESSURE Intracuff pressure and pressure on tracheal wall: It is desirable that cuff seals the airway without extending so much pressure on the trachea so that its circulation is not compromised or trachea is dilated. When cuff is inflated in the trachea, there is a linear decrease in the perfusion. It is reduced when the lateral pressure on the tracheal wall attains 30cm of H20 (22mmHg) and ceases completely at 50cm of H20 (42mmHg). So it is recommended that the pressure on the lateral tracheal wall should be kept between 25-34cm of H20.
  • 111. Intracuff pressure and use of nitrous oxide: The resting intracuff pressure and volume of the cuff inflated with air rise during nitrous oxide anesthesia, which results in ischaemia of the tracheal mucosa or compression of the tube, and increase in volume may lead to cuff herniation.
  • 112. Steps to prevent the increasing pressure includes the following: a) Filling the cuff with gas mixture to be used for anesthesia or saline b) Fitting the cuff system with pressure relief valve or pressure regulating devices. c) Use of special system e.g. Lanz pressure regulating valve, sponge cuff and special tubes like Brandt tubes. d) Monitoring cuff pressure and deflating the cuff as needed.
  • 113. Types of cuffs: a) Low volume high pressure b) High volume low pressure a) Low volume high pressure cuff: They have a small diameter at rest and low residual volume. It requires a high intra-cuff pressure to achieve a seal with the trachea. It has a small area of contact with the trachea and distends and deforms the trachea to a circular shape. .
  • 114. The intra-cuff pressure and lateral pressure on the tracheal wall increase sharply as increments of air are added to the cuff. For this reason use of largest ETT has been advised, so that the cuff will be minimally inflated when a seal is created
  • 115. Advantages: Usually reused, Less expensive Offers better protection against aspiration Better visibility during intubation than low pressure cuffs. There is also low incidence of sore throat. Disadvantages; The most serious risk associated with these cuffs is ischemic damage to the trachea following prolonged use.
  • 116. b) High volume low pressure cuffs: They have a high resting volume, large diameter and a thin competent wall. As it is inflated, it first touches the trachea at its narrow point. As cuff inflation continues the area of contact become larger and the cuff adopts itself to irregular tracheal surface. If the cuff inflation is continued the area in contact will be subjected to increasing pressure and trachea will be distorted to a circular cross section similar to high pressure cuff.
  • 117.
  • 118. Advantage : It is relatively easy to pass devices such as esophageal stethoscope, temperature probes, nasogastric tubes around a low pressure cuffs. Disadvantage: These tubes are more difficult to insert, Obscure the view of the tube tip and larynx The cuff is more friable and thus more likely to be torn during intubation. Incidence of sore throats is greater with these tubes. It may not effectively prevent fluid leakage into lower airway.
  • 119. THE GUIDELINES TO DETERMINE THE SIZE OF ETT: Ideal tube in average Adult male – 8.5mm ID Ideal tube in an average Adult female - 7.5mm ID. Age is recognized as the most reliable indicator of appropriate ETT size for children. 3 months & less ------ 3 mm ID 3 - 9 months ------ 3.5 mm ID Older than 1 year ------ ID in mm = (16 + age in years)/4
  • 120. Younger than 6 years ---3.5 + age in years/3 = ID in mm Older than 6years ---- 4.5 + age in years / 4 = ID in mm Infants below 1kg ----- 2.5mm Infants 1-2 kg ------ 3.0 mm Infants 2-3 kg ------ 3.5 mm Infants 3 kg ------ 4.0 mm Choosing a tube whose external diameter is same width as the patient's distal little finger
  • 121. Other recommendations for size of ET tubes
  • 122. DEPTH OF INSERTION The tube should be in the middle third of the trachea with the head in neutral position. The following calculations can be used. 1) Length in cm = age/2 + 12 2) Length in cm = weight in kg/5 + 12 3) Length in cm = height in cms/10 + 5 4) Length in cm = 3 × ID (mm)
  • 123. In adults, the tube should be passed until the cuff is 2.25 to 2.5cm below the vocal cord In average size adult patients, securing the tube at the anterior incisor at 23cm in males and 21cm in females will usually avoid endobronchial intubation. For nasal intubation 5cm should be added to these length for positioning at the nares.
  • 124. SPECIFIC ET TUBES Cole tube: It is uncuffed ETT, designed for pediatric patients. The patient end is smaller in diameter than the rest of the tube They are sized according to the internal diameter of the tracheal portion. It ranges from 2mm to 5mm.. It is recommended for neonatal resuscitation but not for long term intubation. Disadvantage of this tube is that it cannot be used nasally
  • 125. Spiral embedded tubes: Also known as Armored tube. These tubes have a metal or nylon spiral woven reinforcing wire covered both internally and externally by rubber, PVC or silicone. A stylet is often needed for intubation. These tubes are esp useful in situations where the tube is likely to be bent or compressed as in head & neck surgery
  • 126. Advantages: Primary advantage of tube is resistance to kinking and compression. The portion of the tube outside the patient can be easily angled away from the surgical field without kinking Can be used for patients with Tracheostomies Disadvantages: Tube may rotate on the stylet during intubation. Insertion through nose & intubating LMA is difficult. Fixation of these tubes are more difficult. If the patient bites the tube it will cause permanent deformity resulting in obstruction of the tube.
  • 127. Preformed tubes/Ring-Adair-Elwyn (RAE): It is preformed to facilitate the head & neck surgeries. The tubes are available in cuffed, uncuffed ,nasal and oral version. There is apreformed bend in the tube that may be temporarily straightened for suctioning. Each tube has a rectangular mark at the center of the bend. Distance from this mark to the distal tip is printed on each tube.
  • 128. Oral RAE tubes are shorter than the nasal ones. The external portion is bent at an acute angle so that when in place it rests on patients chin & the connector over the pts chest. Nasal RAE has a curve opposite to the curvature of the oral tube, so that when in place the outer portion of the tube is directed towards patient's forehead
  • 129. Advantages: Easy to secure and reduce the risk of unintended extubation. Breathing system remains away from surgical field Disadvantages: It offers more resistance than conventional tubes. Suctioning is difficult
  • 130. Laryngectomy tube: Designed for insertion into a tracheostomy site. The tube is preformed in a J configuration at the pt end. This allows the part of the tube external to the patient to be directed away from the surgical field. The tip may be short and/or without a bevel to avoid inadvertent advancement into a bronchus.
  • 131. Injectoflex: It is used for laryngeal microsurgery. It is a short cuffed silicone tube designed to be placed below the vocal cords. The tube has an embedded wire spiral to prevent kinking and compression. The cuff inflation lumen and the inflation tube are integrally joined in a sheath with a malleable introducer.
  • 132. Microlaryngeal tracheal surgery tube : Is available with an ID of 4, 5or 6mm, each of which has the same length and cuff diameter as a standard 8mm ID tube. Designed for microlaryngeal tracheal surgery. The small diameter provides better surgical access The problems with this tube are incomplete exhalation & occlusion.
  • 133. Endotrol tubes: A tip control system is incorporated in this tracheal tube to change the direction of the tip. This tube has ring loop at the machine end that is connected to the tip with a cable Pulling the ring causes the tip of the tube to move anteriorly. This is useful when laryngoscopy is difficult and only epiglottis is seen.
  • 134. Tubes with extra lumens: Tubes are available with one or more separate lumens terminating near the tip. They are useful for respiratory gas sampling, airway pressure monitoring, injection of fluids and drugs & jet ventilation.
  • 135. The LITA (Laryngotracheal Instillation of Topical anaesthesia) Has additional small bore channel within the concave surface of the tube. 10 small holes at the distal 13cm of the tube allows the injected medication to be spread both above & below the cuffs. This can provide a smooth emergence from anesthesia without coughing in most cases.
  • 136. EMG Reinforced Tube This tube is designed to monitor recurrent laryngeal nerve electromyogram activity during surgery. The tube is wire-reinforced & has 4 stainless steel electrodes above the cuff. The electrodes are connected to a monitor.
  • 137. Laser-shield II Tracheal Tube: It is designed for use with CO2 and KTP lasers. Made from silicone with an inner aluminium wrap and a smooth Teflon outer coating. The cuff is not laser resistant & contains methylene blue crystals. It should be inflated with water or saline solution. .
  • 138. Cottonoids for wrapping around the cuff are supplied with each tube.These must be moistened and kept moist during the entire procedure Disadvantage : Exposure of unprotected parts of the tube proximal & distal to cuff can result in rapid combustion. The methylene blue crystals may not fully dissolve & may obstruct the pilot tube, making it impossible to deflate.
  • 139. Laser-Flex Tubes: Laser flex tube is a flexible stainless steel tube with a smooth surface designed for used with C02 and KTP (potassium-titanylphosphate) lasers. Adult version has two PVC cuffs and PVC tips with Murphy eye. The tube cuffs are inflated by two separate inflation tubes. The distal cuff can be used if proximal one is damage by laser.
  • 140. The cuff should be filled with saline. The distal cuff should be filled first until sealing occurs, then the proximal cuff is filled with saline coloured with methylene blue. Problems with the laser flex tube include stiffness, roughness, cannot be trimmed. The double cuff adds to the time of intubation and extubation.
  • 141. Lasertubus: This is made of white rubber & has a cuff-within-a cuff design. If the outer cuff is perforated by a laser beam, the trachea will still be sealed by inner cuff. The inner cuff is filled with air & outer with water or saline. The shaft above the cuff is covered by a corrugated silver foil, which is covered by merocel sponge that should be moistened with saline before use. It is recommended for use with argon, NdYAG, CO2 lasers.
  • 142. Hi-Lo Evac Tube It incorporates dedicated channel which can be used to clear secretions below the vocal cords but above the cuff. The lumen may be blocked by secretions.
  • 143. Hi-Lo Jet Tube It is an uncuffed tube with additional lumen that can be used for Jet ventilation, monitoring airway pressure, sampling respiratory gases or administering local anesthetics.
  • 144.   REFERENCES Understanding Anaesthesia Equipment, 5th Edition, Jerry A. Dorsh and Susan E. Dorsh Anaesthetic Equipment, 5th Edition, CS Ward Clinical Anaesthesiology, 4Ih Edition, GE Morgan Benumoff s - Airway management Understanding paediatricanaesthesia – Rebecca Jacob