Cement and Concrete Research 29 (1999) 659–666
0008-8846/99/$–see front matter © 1999 Elsevier Science Ltd. All rights reserved.
PII: S0008-8846(99) 00011- 3
Strength and shrinkage properties of alkali-activated slag
concrete placed into a large column
Frank Collins *, J.G. Sanjayan
Department of Civil Engineering, Monash University, Wellington Road, Clayton, Victoria 3168, Australia
Manuscript received 2 September 1998; accepted manuscript 11 January 1999
Abstract
The properties of alkali-activated slag concrete (AASC) are generally determined on small-scale laboratory-produced prisms or cylinders.
This investigation reports the in situ strength and in situ strain results from measurements on an 800 ϫ 800 ϫ 1200-mm column composed
of AASC produced at a concrete plant. The results are contrasted with those of columns made with ordinary portland cement (OPC) and
blended cement (50% OPC ϩ 50% slag) designated as GB50/50. For this type of AASC, the workability improved from the time of produc-
tion to the time of concrete placement and minimal slump loss occurred over 2 hours (in contrast with OPC). The rate of in situ temperature
development was similar to GB50/50, and slower than OPC; however, the maximum temperature difference between the interior and the ex-
terior was considerably less than OPC and GB50/50. The in situ strength was identical to OPC and superior to GB50/50 at 28 and 91 days.
Embedded strain gauges show small initial in situ expansion within the centre of the column followed by a rapid rate of tensile strain growth
up to 14 days. At 91 days the differential strain between the centre of the column and the corner was sufficient to crack OPC concrete; how-
ever, the AASC column remained uncracked. Possible explanations for this behaviour could be due to a greater tensile strain capacity of
AASC than OPC concrete caused by greater creep and lower elastic modulus and higher tensile strength of AASC. © 1999 Elsevier Sci-
ence Ltd. All rights reserved.
Keywords: Curing; Compressive strength; Shrinkage; Alkali-activated cement; Granulated blast furnace slag
1. Introduction
During construction, structural concrete typically re-
ceives minimal curing following removal of formwork. Al-
though the literature [1–11] reports the significant influence
of curing on the strength development and drying shrinkage
of alkali-activated slag concrete (AASC), the investigations
generally involve testing of laboratory-size specimens.
Whether lack of curing translates into a problem with larger
scale structural concrete members is seldom reported. This
paper reports the results of strength of cores and in situ
measurements of shrinkage strains within an 800 ϫ 800 ϫ
1200-mm column, which are contrasted with measurements
conducted on laboratory-size specimens.
The strength of concrete containing AASC is sensitive to
the curing environment. Talling and Brandstetr [1] report
that loss of moisture during dry air storage reduces strength
between 7 and 28 days. Kutti and colleagues [2] report 35%
strength difference at 36 months age between prisms cured
at 94% relative humidity (RH) compared with 33% RH.
Following air storage at 95 and 70% RH, Talling [3] reports
little difference in cylinder strength; however, when stored
at 50% RH the strength development stops after 28 days and
the strength at 91 days is 86% that of the same cylinders
stored at 95% RH. Cylinders moist-cured for 7 days fol-
lowed by 40% RH were 10.5% lower in compressive
strength at 1 year compared with identical samples cured at
70% RH [4]. This is in contrast with Byfors [5], who re-
corded similar strength when comparing water-cured strength
vs. air-cured (50% RH) strength after initial 7 days wet cur-
ing. Hakkinen [6] reports the same strength at 6 months age
after 28 days of moist curing followed by exposure to 40%
RH, as compared to identical samples exposed to 100% RH.
After 1 day of curing at 40ЊC, cylinders subjected to 40%
RH showed the same 1-year strength as identical samples
subjected to 100% RH [7]. For alternating curing conditions
(7 days 40% RH followed by 7 days Ͼ95% RHfor 10 cy-
cles) Hakkinen [8] and Malalepszy and Deja [9] report sim-
ilar and enhanced strength compared to cylinders stored at
Ͼ95% RH. Sioulas [12] found that the in situ core strength
of blended cement concretes (up to 70% slag) in large-scale
columns is significantly less than that of ordinary portland
cement (OPC) control concrete and up to 35% less than
* Corresponding author. Tel.: 61-3-990-54959; Fax: 61-3-990-54944;
E-mail: frank.collins@eng.monash.edu.au.
660 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666
bath-cured cylinder strength. Hakkinen [8] showed that dry
exposed AASC displays a size effect, whereby the strength
of larger samples (up to 150-mm diameter cylinders) is less
affected than smaller samples by surface microcracks devel-
oped during drying. The in situ strength variations of a large
structure member following exposed curing is unreported.
Drying shrinkage strain of AASC is sensitive to the ex-
posure environment, although there are differences in the
reported magnitude. Kutti [2] found that for RH Ͼ 70% the
drying shrinkage for AASC was similar to OPC. However,
at RH 33% and RH 50% the drying shrinkage was 3.0 and
2.3 times the drying shrinkage of OPC. During bath curing
AASC swells compared with OPC [4,10,11], whereas under
exposure condition of 70% RH, AASC has 32% greater dry-
ing shrinkage than OPC [4]. There are conflicting views on
the reported long-term drying shrinkage. Douglas, Bilo-
deau, and Malhotra [11] report higher drying shrinkage at
224 days (50% RH) for AASC than OPC concrete, whereas
Hakkinen [6] and Kukko and Mannonen [7] found no sig-
nificant difference after 500 days exposure at 40% RH be-
tween AASC and OPC concrete for which the proportioning
of constituents by weight was the same. The shrinkage be-
haviour of AASC larger in size than laboratory prisms is un-
reported.
2. Experimental programme
1 cubic meter of AASC mixture was made at a concrete
plant and mixed in a 2-m3
agitator truck. A column 800 ϫ
800 mm in cross section and 1200 mm high was made, to-
gether with samples for laboratory testing of strength and
shrinkage under different curing conditions. In situ monitor-
ing of the column has been conducted for temperature and
ongoing strain using embedded thermocouples and vibrat-
ing wire strain gauges. Strength has been monitored using
extracted cores.
The chemical composition and properties of the cementi-
tious binders are summarised in Table 1. The binders used
are ground granulated blast furnace slag (slag) and OPC.
The term water/binder (w/b) ratio is used instead of water/
cement ratio to include all the binders mentioned above.
The slag is supplied with gypsum (2% SO3), which is blended
with the slag. The activators and adjuncts utilised were pow-
dered sodium metasilicate and hydrated lime (L). The dry
powdered silicate activator was preblended with the slag in
the dry form prior to use for concrete manufacture. The hy-
drated lime was added to the mix (1% weight of slag) as a 1:3
(hydrated lime:water) mixture to improve workability. The
optimisation of the activator is not discussed in this paper.
The coarse aggregate consisted of 14-mm maximum size
basalt that has a specific gravity of 2.95 and 24-hour water
absorption of 1.2%. The fine aggregate consisted of river
sand that has a specific gravity of 2.65, 24-hour water ab-
Table 1
Properties of cementitious materials
Constituent/property Slag OPC
SiO2 (%) 35.04 19.9
Al2O3 (%) 13.91 4.62
Fe2O3 (%) 0.29 3.97
MgO (%) 6.13 1.73
CaO (%) 39.43 64.27
Na2O (%) 0.34
TiO2 (%) 0.42
K2O (%) 0.39 0.57
P2O5 (%) Ͻ0.1
MnO (%) 0.43
Total sulphur as SO3 (%) 2.43 2.56
Sulphide Sulphur as S2Ϫ
0.44
Cl (p.p.m.) 80
Fineness (m2
/kg) 460 342
Loss on ignition (%) 1.45 2.9
Time to initial set (hours) N/A 2.0
Strength of 70 ϫ 70 ϫ 70 mm
mortarcubes(MPa)
3 Days N/A 32.7
7 Days 42.0
28 Days 54.1
Table 2
Summary of concrete mixture proportions (per kg m3
)
Constituents OPC10
GB50/5010
AASC
OPC 360 180
Slag 180 360
Free water 180 180 180
w/b 0.5 0.5 0.5
Fine aggregate 830 830 830
Coarse aggregate, 14 mm 1130 1130 1130
Air content % 0.5 1.2 1.2 Fig. 1. Steel formwork used to cast the column.
F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 661
tions for OPC and blended cement (50% OPC ϩ 50% slag,
GB50/50) mixes [12]. Allowance was made for moisture
content in the aggregates, powdered sodium silicate activator,
and hydrated lime slurry to ensure correct free water content
in the mix. The development of activator optimisation and
concrete mix design are reported in unpublished work.
The batching sequence was as follows:
1. An initial 80-litre load of water was charged into the
agitator truck using a metered pump.
2. 50% of the sand and coarse aggregate was then added.
3. The preblended slag and activator was hand-loaded.
4. The remaining sand and coarse aggregate was then
loaded.
5. The hydrated lime slurry was then added, followed by
increments of water to obtain the desired workability
(100-mm design slump).
The total time taken for the above steps was approximately
20 minutes. The travel time from the concrete plant to the
concrete laboratory was 30 minutes.
The configuration of the column formwork is shown in
Fig. 1. The column was cast onto a 100-mm layer of poly-
styrene, over which was a sheet of polythene plastic. The
column was cast in three layers, as shown in Fig. 2. The pur-
pose of the three layers was to assist the handling and trans-
port of concrete for subsequent coring of each layer for
Fig. 2. Elevation of column.
Fig. 3. Layout of thermocouples (ϫ) and VWG strain gauges within cross section.
sorption of 0.5%, and a fineness modulus of 2.19. Propor-
tioning was for saturated and surface dry conditions.
The concrete mixture proportions for AASC are sum-
marised in Table 2. Also shown are reference mix propor-
662 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666
strength testing. The layers were separated by wet corru-
gated cardboard placed on either side of a masonite board.
A 100-mm sacrificial layer, designed to negate the influ-
ences of boundary bleed and temperature transfer, was al-
lowed at each boundary separator. The lower sacrificial
layer also served to accommodate instrumentation, as dis-
cussed below. The formwork was removed 24 hours after
concrete placement, and the column was stored at 22–25Њ C
and 65–70% RH.
A set of thermocouples and vibrating wire strain gauges
(VWG) were installed within the lower sacrificial layer, as
shown in Fig. 3. Type T copper/nickel thermocouples were
installed along radial arms from the centre of the column,
oriented at 90, 60, and 45Њ to the direction of the side face of
the column. The spacing of thermocouples to the side face
of a column were 0, 25, 50, 100, 200, and 400 mm. Another
thermocouple was located immediately outside the column
to ascertain ambient temperature variations. Readings were
discontinued at 72 hours when the temperatures had equili-
brated.
In situ strain was measured by purpose-built embeddable
VWG. The gauge length was 150 mm. The gauges were lo-
cated at 25, 200, and 400 mm from the column face as well
as at a corner, as shown in Fig. 3. The coring schedule is
shown in Fig. 4. The core strengths at 28 and 91 days from
the date of concrete placement are reported.
Samples were also made for subsequent laboratory test-
ing as follows:
• Standard cylinders (100-mm diameter and 200-mm
height) for compressive strength testing in triplicate at
1, 3, 7, 28, 56, 91 days, and 1 year (following demoul-
ding, “bath” curing in Ca(OH)2 saturated water at 23ЊC,
“exposed” curing at 23ЊC and 50% RH, and “sealed”
curing involving storage in two polythene bags and a
sealed container at 23ЊC). The sealed and exposed cur-
ing environments were chosen to simulate curing ex-
tremes within a large column.
• Standard shrinkage prisms (75 ϫ 75 ϫ 285 mm) were
made. The exposure conditions following demoulding
for a triplicate set of samples were exposed, sealed,
and followed AS1012, Part 13 (i.e., 7 days bath cured
followed by exposed curing at 23ЊC and 50% RH).
• Properties of fresh concrete such as slump and air con-
tent were also determined.
2. Results
2.1. Fresh concrete properties
The workability of the concrete improved from the time
of first mixing at the concrete plant (100-mm slump) to the
time of delivery (150-mm slump). This was also observed in
the case of the laboratory mixes where the slump at 30 min-
utes was better than the slump at the time of mixing. The
slump loss over 2 hours was minimal. This can be explained
by the slow dissolution of solid sodium silicate into the mix-
Fig. 4. Coring schedule (coring ages shown in days).
F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 663
ing water and that the sodium silicate acts as a water re-
ducer. This is in contrast with other types of AASC whereby
certain activator types can cause significant loss of work-
ability. The air content of 1.2% was identical to the labora-
tory prepared AASC.
2.2. In situ temperature development due to heat
of hydration
Fig. 5 shows the temperature development along ARM
45 (Fig. 3). Only ARM 45 is reported since it shows the
greatest thermal gradient due to the biaxial cooling at the
column corner. Fig. 5 shows lower rate of temperature rise
and lower peak temperature at the centre of the column
compared with an OPC column, as summarised in Table 3.
AASC reached peak temperature at 18 hours, which was
identical to GB50/50, although the temperature gradient
was less. The dissolution of solid sodium silicate activator is
a slow and endothermic process and this has contributed to
the lower heat development of this activator type. This con-
trasts with other types of activators that show more rapid re-
action with slag [13].
2.3. Compressive strength—standard cylinders
The exposed and sealed curing conditions, as described
above, were chosen to simulate the likely curing environ-
ment at the outside and at the centre of the columns. The test
results for AASC up to 91 days are summarised in Fig. 6.
The 1-day strength was 17.5 MPa. There is a significant dif-
ference in strength between samples subjected to exposed
curing and sealed/bath curing. Beyond 28 days, the exposed
concrete strength levels off whereas the sealed and bath
cured cylinders show continued strength gain.
At 28 days, AASC had 20 and 24% greater strength than
GB50/50 concrete under bath and sealed curing, respec-
tively. However, it was 9 and 3% lower in strength than
OPC concrete. At 91 days, the compressive strength of
AASC surpasses both OPC and GB50/50 concretes.
2.4. Compressive strength—extracted cores
Figs. 7 and 8 show core strength vs. depth into the col-
umn along ARM 45 at 28 and 91 days. The results are com-
pared with those of OPC and GB50/50 concrete cores ob-
tained from identical columns [12].
At 28 days AASC shows significantly higher in situ
strength than GB50/50 concrete and almost identical in situ
strength to the OPC column at the corner and at the centre.
The trend is towards higher in situ strength near the centre
of the column where the effects of drying are minimal.
At 91 days the AASC shows a very small increase in the
in situ strength (from 28 days) and shows the same trend as
at 28 days, where the strength increases with depth into the
concrete. The strength is very similar to OPC at all depths,
with a slightly higher in situ strength at the centre of the col-
umn. Both OPC and AASC show higher in situ strength
than GB50/50 at 91 days, although the difference in strength
is not as pronounced as at 28 days.
The effects of drying at the corners, as opposed to at a
single face, cause little difference in strength (4% lower at
28 days and 1% lower at 91 days).
Horizontal cores (i.e., perpendicular to the direction of
concrete placement) were drilled in the AASC column at 91
days. The core locations are shown in Fig. 4. The mean core
strength was 39.0 MPa. The strengths are lower than the
core strengths of samples drilled vertically at the corners,
and this is most likely due to the fact that the strength of
horizontally drilled cores is lower than that of cores drilled
vertically with respect to the direction of casting [14–16].
The difference in strength between cores located at the
corner and the centre of the column is shown in Table 4. De-
spite no curing of the column exterior from day 1 on, the
strength difference between the interior and the exterior of
the column is not as pronounced as for the laboratory-exposed
curing versus sealed curing. The laboratory-exposed curing
environment for cylinders (23ЊC and 50% relative humid-
ity) is more onerous than the in situ curing conditions expe-
rienced by the column (22–25ЊC and 65–70% RH), as evi-
denced by the strength results. The core strength at the
centre of the column has identical strength at 28 days and
89% at 91 days to the sealed cured standard cylinders. The
core strength at the centre of the column is 92 and 80% of
Table 3
Temperature differences between the three column types
Concrete type
Peak
temperature (ЊC)
Time after
casting
(hours)
Maximum centre
to surface temperature
difference (ЊC)
AASC 41.5 18 10.5
OPC10
46.5 13.5 20.0
GB50/5010
36.5 18 15.0
Fig. 5. Temperature development within AASC column along ARM 45.
Numbers in parentheses refer to thermocouple numbers shown in Fig. 3.
664 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666
standard bath cured cylinders at 28 and 91 days, respec-
tively.
2.5. Drying shrinkage
Fig. 9 summarises the drying shrinkage results obtained
according to AS1012, Part 13 (i.e., 7 days bath curing fol-
lowed by exposed curing at 23ЊC and 50% RH), shrinkage
following sealed curing, and also drying shrinkage following
exposure from day 1. AASC shows minor expansions during
the first 7 days, when bath and sealed cured, followed by a
considerably higher rate of drying shrinkage when exposed.
When exposed from day 1, the overall shrinkage strains are
higher than the prisms tested to AS1012, Part 13, most likely
due to the greater moisture loss during the first 7 days.
2.6. In situ strain development
The VWG gauges located within the interior of the column
show small expansions within the first few days (Fig. 10), as
was also observed with measurements on laboratory prisms un-
der sealed curing conditions (Fig. 9). Beyond 3 days, tensile
strain develops rapidly and the differential shrinkage between
the interior and the corner gauges is 71 microstrain at 12 days
and 149 microstrain at 91 days. The total strains are less than
the prisms, although this can be explained as a volume-to-area
ratio effect. For OPC concrete this could lead to cracking be-
cause concrete has a tensile strain capacity in the order of 70–
90 microstrain depending on the type of aggregate [17]. How-
ever, apart from minor surface cracking, no major shrinkage-
related cracking was visible. A possible explanation as to why
cracking was not observed may be that the greater tensile strain
capacity of AASC than OPC concrete caused by greater creep
and lower elastic modulus, which is reported in a publication
under review [18]. Another possible explanation is that the ten-
sile strength of AASC may be higher than OPC, as evidenced
by higher flexural strength than OPC concrete [18]. The com-
bined effects of restraint, drying shrinkage, and creep are cur-
rently under investigation.
3. Conclusions
The results of this investigation indicate that:
1. For this type of AASC, which was based on a solid
sodium silicate activator and produced at a concrete
Fig. 6. Effect of curing on compressive strength of standard cylinders composed of AASC.
Fig. 7. Summary of core strengths at 28 days. Fig. 8. Summary of core strengths at 91 days.
F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 665
plant, workability improved from the time of produc-
tion to the time of concrete placement (30 minutes)
and showed minimal slump loss over 2 hours.
2. A column made with AASC based on solid sodium
silicate activator reached the peak in situ temperature
at 18 hours after casting. This was identical to GB50/
50, whereas OPC concrete reached its peak tempera-
ture at 13.5 hours. The maximum temperature differ-
ence between the centre and exterior of the column
was 10.5ЊC for AASC, whereas OPC and GB50/50
were 20ЊC and 15ЊC, respectively.
3. Laboratory-exposed (23ЊC and 50% RH) cylinders
show considerable strength difference to sealed cured
cylinders (31% at 91 days) and the strength develop-
ment at ages beyond 28 days.
4. The in situ strength of AASC at 28 and 91 days is sim-
ilar to those of OPC, with strength increasing towards
the centre of the column where the effects of drying are
minimal. The in situ strength is superior to that of
GB50/50. The strength difference between the interior
of the column and the exterior is 10%, which is consid-
erably better than the laboratory-simulated conditions.
5. Measurements from embedded strain gauges showed
small in situ expansions within the centre of the col-
umn, which was also measured on laboratory prisms
under sealed curing conditions. At 91 days the differ-
ential strain between the centre of the column and the
corner location was 149 microstrain. This would be
sufficient to crack OPC concrete, whereas the AASC
column remained uncracked. One possible explana-
tion is that AASC has higher tensile strain capacity
and also greater tensile strength than OPC concrete
[18]. The combined effects of restraint, drying shrink-
age, and creep are currently under investigation.
Acknowledgments
The financial support for this project is jointly provided
by Independent Cement and Lime Pty Ltd., Blue Circle
Southern Cement Ltd., and Australian Steel Mill Services.
The authors thank the sponsors, especially Alan Dow, Tom
Wauer, John Ashby, Kathryn Turner, Paul Ratcliff, and Dr.
Ihor Hinczak for guidance and support. The efforts and as-
sistance with the laboratory work provided by Jeff Doddrell
and Peter Dunbar are also gratefully acknowledged.
References
[1] B. Talling, J. Brandstetr, Proceedings 3rd CANMET/ACI Int. Conf.
on Fly Ash, Slag, and Natural Pozzolans in Concrete, Trondheim,
Norway, ACI SP 114 (2) (1989) 1519.
Table 4
Comparison of core strengths at the column corner and center with cylinder strengths
Core strength (MPa) Cylinder strength (Mpa)
Age Location AASC OPC GB50/50 Curing type AASC OPC GB50/50
28 days Corner (exterior) 40.5 39.5 27.5 Exposed 36.0 Not conducted
Centre (interior) 44.5 46.5 35.0 Sealed 44.5 46.0 36.0
External face 42.0 46.0 32.5 Bath 48.5 53.0 40.5
91 days Corner (exterior) 40.5 44.0 34.0 Exposed 35.0 Not conducted
Centre (interior) 45.0 43.5 41.5 Sealed 50.5 50.0 43.5
External face 42.5 44.0 38.0 Bath 56.0 54.0 52.5
Fig. 9. Shrinkage strains of standard prisms following exposure to different curing regimes (AASC).
666 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666
[2] T. Kutti, L. Berntsson, S. Chandra, Proceedings 4th CANMET/ACI
Int. Conf. on Fly Ash, Slag, and Natural Pozzolans in Concrete, Istan-
bul, Turkey, Supplementary Papers (1992) 615–625.
[3] B. Talling, Proceedings 3rd CANMET/ACI Int. Conf. on Fly Ash,
Slag, and Natural Pozzolans in Concrete, Trondheim, Norway, ACI
SP 114 (2) (1989) 1485.
[4] T. Hakkinen, Cem Concr Res 23 (2) (1993) 407.
[5] K. Byfors, G. Klingstedt, V. Lehtonen, H. Pyy, L. Romben, Proceed-
ings, ACI SP 114 (2) (1989) 1429.
[6] T. Hakkinen, Techn. Res. Centre Finl. Res. Notes (1986) 540.
[7] H. Kukko, R. Mannonen, Nord. Conc. Res., Publ. 1, Oslo, Nord.
Conc. Fed. (1982) 16.1–16.16.
[8] T. Hakkinen, Cem Concr Res 23 (3) (1993) 518.
[9] J. Malalepszy, J. Deja, Sil Indust 11–12 (1988) 179.
[10] P.M. Gifford, J.E. Gillott, Can J Civ Eng 24 (1996) 237.
[11] E. Douglas, A. Bilodeau, V.M. Malhotra, ACI Mat J 89 (5) (1992) 509.
[12] B. Sioulas, MEng Thesis, Dep. Civil Eng., Monash University, 1996.
[13] F. Collins, J.G. Sanjayan, Cem Concr Res 28 (5) (1998) 655.
[14] Concrete Core Testing for Strength, Concrete Society Technical Re-
port No. 11, 1976.
[15] Addendum (1987) to Concrete Core Testing for Strength, Concrete
Society Technical Report No. 11, 1976.
[16] A. Takahata, T. Iwashimizu, U. Ishibashi, Utilisation of High
Strength Concrete—2nd Int. Symp., ACI SP 121 (1989) 741.
[17] P. Bamforth, Digest No. 2, Concrete Society, UK, 1984.
[18] F. Collins, J.G. Sanjayan, Cem Conc Res 29 (3) (1999) 455–458.
Fig. 10. In situ strain development (VWG locations as shown in Fig. 3). VWG1, located at centre of column; VWG2, located 200 mm from centre; VWG3,
located at outside face in middle; VWG4, at corner at edge.

Mais conteúdo relacionado

Mais procurados

MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)
MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)
MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)Stacy Holton
 
Workability studies on concrete with ggbs as a replacement material for cemen...
Workability studies on concrete with ggbs as a replacement material for cemen...Workability studies on concrete with ggbs as a replacement material for cemen...
Workability studies on concrete with ggbs as a replacement material for cemen...iaemedu
 
Ground granulated blast furnace slag ggbs
Ground granulated blast furnace slag ggbsGround granulated blast furnace slag ggbs
Ground granulated blast furnace slag ggbsthe_inspiredchaos
 
Experimental Study on Partial Replacement of Cement by Flyash and GGBS
Experimental Study on Partial Replacement of Cement by Flyash and GGBSExperimental Study on Partial Replacement of Cement by Flyash and GGBS
Experimental Study on Partial Replacement of Cement by Flyash and GGBSijsrd.com
 
Experimental Study on Durability Characteristics of High Performance Concrete...
Experimental Study on Durability Characteristics of High Performance Concrete...Experimental Study on Durability Characteristics of High Performance Concrete...
Experimental Study on Durability Characteristics of High Performance Concrete...theijes
 
Development of mix design for high strength Concrete with Admixtures
Development of mix design for high strength Concrete with AdmixturesDevelopment of mix design for high strength Concrete with Admixtures
Development of mix design for high strength Concrete with AdmixturesIOSR Journals
 
A Review On Development Of Flyash Based High Strength Geopolymer Concrete
A Review On Development Of Flyash Based High Strength Geopolymer ConcreteA Review On Development Of Flyash Based High Strength Geopolymer Concrete
A Review On Development Of Flyash Based High Strength Geopolymer Concretecedmmantc5411
 
Evaluation of durability properties of recycled aggregate concrete incorporat...
Evaluation of durability properties of recycled aggregate concrete incorporat...Evaluation of durability properties of recycled aggregate concrete incorporat...
Evaluation of durability properties of recycled aggregate concrete incorporat...IEI GSC
 
Iaetsd experimental study on properties of ternary blended fibre
Iaetsd experimental study on properties of ternary blended fibreIaetsd experimental study on properties of ternary blended fibre
Iaetsd experimental study on properties of ternary blended fibreIaetsd Iaetsd
 
Triple Blending/Ternary Blending (GGBFS + PFA + OPC)
Triple Blending/Ternary Blending (GGBFS + PFA + OPC)Triple Blending/Ternary Blending (GGBFS + PFA + OPC)
Triple Blending/Ternary Blending (GGBFS + PFA + OPC)Zelkhan
 
AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...
AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...
AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...AM Publications
 
RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...
RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...
RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...Ijripublishers Ijri
 
Drying shrinkage behaviour of structural lightweight aggregate concrete conta...
Drying shrinkage behaviour of structural lightweight aggregate concrete conta...Drying shrinkage behaviour of structural lightweight aggregate concrete conta...
Drying shrinkage behaviour of structural lightweight aggregate concrete conta...University of Malaya
 
An Experimental Investigation on Strength Characteristics of Concrete with Pa...
An Experimental Investigation on Strength Characteristics of Concrete with Pa...An Experimental Investigation on Strength Characteristics of Concrete with Pa...
An Experimental Investigation on Strength Characteristics of Concrete with Pa...ijsrd.com
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentIJERD Editor
 

Mais procurados (20)

MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)
MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)
MASTER'S THESIS DEFENSE PRESENTATION (Sept 16)
 
Workability studies on concrete with ggbs as a replacement material for cemen...
Workability studies on concrete with ggbs as a replacement material for cemen...Workability studies on concrete with ggbs as a replacement material for cemen...
Workability studies on concrete with ggbs as a replacement material for cemen...
 
Ground granulated blast furnace slag ggbs
Ground granulated blast furnace slag ggbsGround granulated blast furnace slag ggbs
Ground granulated blast furnace slag ggbs
 
Experimental Study on Partial Replacement of Cement by Flyash and GGBS
Experimental Study on Partial Replacement of Cement by Flyash and GGBSExperimental Study on Partial Replacement of Cement by Flyash and GGBS
Experimental Study on Partial Replacement of Cement by Flyash and GGBS
 
Experimental Study on Durability Characteristics of High Performance Concrete...
Experimental Study on Durability Characteristics of High Performance Concrete...Experimental Study on Durability Characteristics of High Performance Concrete...
Experimental Study on Durability Characteristics of High Performance Concrete...
 
Development of mix design for high strength Concrete with Admixtures
Development of mix design for high strength Concrete with AdmixturesDevelopment of mix design for high strength Concrete with Admixtures
Development of mix design for high strength Concrete with Admixtures
 
E0210023027
E0210023027E0210023027
E0210023027
 
A Review On Development Of Flyash Based High Strength Geopolymer Concrete
A Review On Development Of Flyash Based High Strength Geopolymer ConcreteA Review On Development Of Flyash Based High Strength Geopolymer Concrete
A Review On Development Of Flyash Based High Strength Geopolymer Concrete
 
Evaluation of durability properties of recycled aggregate concrete incorporat...
Evaluation of durability properties of recycled aggregate concrete incorporat...Evaluation of durability properties of recycled aggregate concrete incorporat...
Evaluation of durability properties of recycled aggregate concrete incorporat...
 
Iaetsd experimental study on properties of ternary blended fibre
Iaetsd experimental study on properties of ternary blended fibreIaetsd experimental study on properties of ternary blended fibre
Iaetsd experimental study on properties of ternary blended fibre
 
Hl3513071310
Hl3513071310Hl3513071310
Hl3513071310
 
Sai_ram_Project_Final_Report[1]
Sai_ram_Project_Final_Report[1]Sai_ram_Project_Final_Report[1]
Sai_ram_Project_Final_Report[1]
 
Triple Blending/Ternary Blending (GGBFS + PFA + OPC)
Triple Blending/Ternary Blending (GGBFS + PFA + OPC)Triple Blending/Ternary Blending (GGBFS + PFA + OPC)
Triple Blending/Ternary Blending (GGBFS + PFA + OPC)
 
AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...
AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...
AN EXPERIMENTAL STUDY ON PROPERTIES OF TERNARY BLENDED CONCRETE USING GGBS AN...
 
RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...
RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...
RESIDUAL COMPRESSIVE STRENGTH OF TERNARY BLENDED CONCRETE AT ELEVATED TEMPERA...
 
Concrete, Ternary Blending Concrete IDM8
Concrete, Ternary Blending Concrete IDM8Concrete, Ternary Blending Concrete IDM8
Concrete, Ternary Blending Concrete IDM8
 
Drying shrinkage behaviour of structural lightweight aggregate concrete conta...
Drying shrinkage behaviour of structural lightweight aggregate concrete conta...Drying shrinkage behaviour of structural lightweight aggregate concrete conta...
Drying shrinkage behaviour of structural lightweight aggregate concrete conta...
 
An Experimental Investigation on Strength Characteristics of Concrete with Pa...
An Experimental Investigation on Strength Characteristics of Concrete with Pa...An Experimental Investigation on Strength Characteristics of Concrete with Pa...
An Experimental Investigation on Strength Characteristics of Concrete with Pa...
 
H044053842
H044053842H044053842
H044053842
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
 

Destaque

Activ Slag - Ieaust transactions
Activ Slag - Ieaust transactionsActiv Slag - Ieaust transactions
Activ Slag - Ieaust transactionsfrank collins
 
Microcracking-Activated Slag (C&CC)
Microcracking-Activated Slag (C&CC)Microcracking-Activated Slag (C&CC)
Microcracking-Activated Slag (C&CC)frank collins
 
Workability&MechProperties-AASC
Workability&MechProperties-AASCWorkability&MechProperties-AASC
Workability&MechProperties-AASCfrank collins
 
Peter Keeley Discusses APCr
Peter Keeley Discusses APCrPeter Keeley Discusses APCr
Peter Keeley Discusses APCrJessica Smith
 
Cracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concreteCracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concretefrank collins
 
PoreSizeDistribution-AASC
PoreSizeDistribution-AASCPoreSizeDistribution-AASC
PoreSizeDistribution-AASCfrank collins
 
Early age strength and workability of slag pastes activated by sodium silicates
Early age strength and workability of slag pastes activated by sodium silicatesEarly age strength and workability of slag pastes activated by sodium silicates
Early age strength and workability of slag pastes activated by sodium silicatesfrank collins
 
ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)frank collins
 
Effect of activator dosage... (2014, SAICE, Shekhovtsova J)
Effect of activator dosage... (2014, SAICE, Shekhovtsova J)Effect of activator dosage... (2014, SAICE, Shekhovtsova J)
Effect of activator dosage... (2014, SAICE, Shekhovtsova J)Maxim Kovtun
 
EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...
EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...
EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...SJ BASHA
 
Environmental Performances of Bricks made from Stainless Steel Slag: A Life ...
Environmental Performances of Bricks made from Stainless Steel Slag:  A Life ...Environmental Performances of Bricks made from Stainless Steel Slag:  A Life ...
Environmental Performances of Bricks made from Stainless Steel Slag: A Life ...DS2BE
 
Feasibility studies of geopolymer as a coating material
Feasibility studies of geopolymer as a coating materialFeasibility studies of geopolymer as a coating material
Feasibility studies of geopolymer as a coating materialzerohead
 
30 years in geopolymer applications
30 years in geopolymer applications30 years in geopolymer applications
30 years in geopolymer applicationsTran Nam
 
Application of micromechanics on alkali activated materials
Application of micromechanics on alkali activated materialsApplication of micromechanics on alkali activated materials
Application of micromechanics on alkali activated materialsTran Nam
 
Constituents and applications in concrete
Constituents and applications in concreteConstituents and applications in concrete
Constituents and applications in concreterama rao
 

Destaque (20)

Activ Slag - Ieaust transactions
Activ Slag - Ieaust transactionsActiv Slag - Ieaust transactions
Activ Slag - Ieaust transactions
 
Microcracking-Activated Slag (C&CC)
Microcracking-Activated Slag (C&CC)Microcracking-Activated Slag (C&CC)
Microcracking-Activated Slag (C&CC)
 
Workability&MechProperties-AASC
Workability&MechProperties-AASCWorkability&MechProperties-AASC
Workability&MechProperties-AASC
 
Peter Keeley Discusses APCr
Peter Keeley Discusses APCrPeter Keeley Discusses APCr
Peter Keeley Discusses APCr
 
Cracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concreteCracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concrete
 
Stallion Energy Pvt. Ltd, Rajkot, Fossil Fuels
Stallion Energy Pvt. Ltd, Rajkot, Fossil FuelsStallion Energy Pvt. Ltd, Rajkot, Fossil Fuels
Stallion Energy Pvt. Ltd, Rajkot, Fossil Fuels
 
UltrafineAASC
UltrafineAASCUltrafineAASC
UltrafineAASC
 
PoreSizeDistribution-AASC
PoreSizeDistribution-AASCPoreSizeDistribution-AASC
PoreSizeDistribution-AASC
 
Early age strength and workability of slag pastes activated by sodium silicates
Early age strength and workability of slag pastes activated by sodium silicatesEarly age strength and workability of slag pastes activated by sodium silicates
Early age strength and workability of slag pastes activated by sodium silicates
 
ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)
 
Effect of activator dosage... (2014, SAICE, Shekhovtsova J)
Effect of activator dosage... (2014, SAICE, Shekhovtsova J)Effect of activator dosage... (2014, SAICE, Shekhovtsova J)
Effect of activator dosage... (2014, SAICE, Shekhovtsova J)
 
EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...
EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...
EFFECT OF DIFFERENT NANOPARTICLES ON PHYSICAL AND MECHANICAL PROPERTIES OF CO...
 
Environmental Performances of Bricks made from Stainless Steel Slag: A Life ...
Environmental Performances of Bricks made from Stainless Steel Slag:  A Life ...Environmental Performances of Bricks made from Stainless Steel Slag:  A Life ...
Environmental Performances of Bricks made from Stainless Steel Slag: A Life ...
 
Challenges for Concrete - Karen Scrivener
Challenges for Concrete - Karen ScrivenerChallenges for Concrete - Karen Scrivener
Challenges for Concrete - Karen Scrivener
 
Feasibility studies of geopolymer as a coating material
Feasibility studies of geopolymer as a coating materialFeasibility studies of geopolymer as a coating material
Feasibility studies of geopolymer as a coating material
 
30 years in geopolymer applications
30 years in geopolymer applications30 years in geopolymer applications
30 years in geopolymer applications
 
49
4949
49
 
Application of micromechanics on alkali activated materials
Application of micromechanics on alkali activated materialsApplication of micromechanics on alkali activated materials
Application of micromechanics on alkali activated materials
 
Constituents and applications in concrete
Constituents and applications in concreteConstituents and applications in concrete
Constituents and applications in concrete
 
20320140504001
2032014050400120320140504001
20320140504001
 

Semelhante a AASC-PlacedLargeColumn

STUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETE
STUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETESTUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETE
STUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETEAbhilash Chandra Dey
 
Effect management of elevated temperature on mechanical and microstructure pr...
Effect management of elevated temperature on mechanical and microstructure pr...Effect management of elevated temperature on mechanical and microstructure pr...
Effect management of elevated temperature on mechanical and microstructure pr...IAEME Publication
 
Effect of Steel Fiber on Alkali activated Fly Ash Concrete
Effect of Steel Fiber on Alkali activated Fly Ash ConcreteEffect of Steel Fiber on Alkali activated Fly Ash Concrete
Effect of Steel Fiber on Alkali activated Fly Ash ConcreteIJERA Editor
 
9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdf
9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdf9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdf
9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdfMuthumari Ganesan
 
An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...
An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...
An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...IRJET Journal
 
Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...
Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...
Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...ijsrd.com
 
As32709714
As32709714As32709714
As32709714IJMER
 
Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...
Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...
Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...IJERD Editor
 
Alcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptx
Alcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptxAlcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptx
Alcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptxShelkeMsShreyaManish
 
Compressive strength variability of brown coal fly ash geopolymer concrete
Compressive strength variability of brown coal fly ash geopolymer concreteCompressive strength variability of brown coal fly ash geopolymer concrete
Compressive strength variability of brown coal fly ash geopolymer concreteeSAT Publishing House
 
Properties of Glass Fibre Reinforced Geopolymer Concrete
Properties of Glass Fibre Reinforced Geopolymer ConcreteProperties of Glass Fibre Reinforced Geopolymer Concrete
Properties of Glass Fibre Reinforced Geopolymer ConcreteIJMER
 
Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...
Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...
Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...ijsrd.com
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentIJERD Editor
 
IRJET- Properties of Cellular Concrete with Inclusion of Silica Fume in P...
IRJET-  	  Properties of Cellular Concrete with Inclusion of Silica Fume in P...IRJET-  	  Properties of Cellular Concrete with Inclusion of Silica Fume in P...
IRJET- Properties of Cellular Concrete with Inclusion of Silica Fume in P...IRJET Journal
 
Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...
Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...
Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...Salih Taner YILDIRIM
 
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...IJERD Editor
 

Semelhante a AASC-PlacedLargeColumn (20)

Bendable concrete
Bendable concreteBendable concrete
Bendable concrete
 
STUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETE
STUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETESTUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETE
STUDY OF MECHANICAL AND DURABILITY PROPERTIES OF GEOPOLYMER CONCRETE
 
Effect management of elevated temperature on mechanical and microstructure pr...
Effect management of elevated temperature on mechanical and microstructure pr...Effect management of elevated temperature on mechanical and microstructure pr...
Effect management of elevated temperature on mechanical and microstructure pr...
 
3048-8524-1-PB.pdf
3048-8524-1-PB.pdf3048-8524-1-PB.pdf
3048-8524-1-PB.pdf
 
Effect of Steel Fiber on Alkali activated Fly Ash Concrete
Effect of Steel Fiber on Alkali activated Fly Ash ConcreteEffect of Steel Fiber on Alkali activated Fly Ash Concrete
Effect of Steel Fiber on Alkali activated Fly Ash Concrete
 
9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdf
9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdf9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdf
9c54f85d-e0b6-4a6d-86e2-52aecc15e680.pdf
 
An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...
An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...
An Investigation on the Effect of Partial Replacement of Cement by Zeolite on...
 
Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...
Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...
Study on effect of Alccofine & Fly ash addition on the Mechanical properties ...
 
As32709714
As32709714As32709714
As32709714
 
L0124598103
L0124598103L0124598103
L0124598103
 
Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...
Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...
Fly Ash as a Partial Replacement of Cement in Concrete and Durability Study o...
 
Project
Project Project
Project
 
Alcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptx
Alcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptxAlcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptx
Alcoffine and fly ash PPT PRANAV ASHOK DEOLE.pptx
 
Compressive strength variability of brown coal fly ash geopolymer concrete
Compressive strength variability of brown coal fly ash geopolymer concreteCompressive strength variability of brown coal fly ash geopolymer concrete
Compressive strength variability of brown coal fly ash geopolymer concrete
 
Properties of Glass Fibre Reinforced Geopolymer Concrete
Properties of Glass Fibre Reinforced Geopolymer ConcreteProperties of Glass Fibre Reinforced Geopolymer Concrete
Properties of Glass Fibre Reinforced Geopolymer Concrete
 
Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...
Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...
Effect of Alccofine and Fly Ash Addition on the Durability of High Performanc...
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
 
IRJET- Properties of Cellular Concrete with Inclusion of Silica Fume in P...
IRJET-  	  Properties of Cellular Concrete with Inclusion of Silica Fume in P...IRJET-  	  Properties of Cellular Concrete with Inclusion of Silica Fume in P...
IRJET- Properties of Cellular Concrete with Inclusion of Silica Fume in P...
 
Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...
Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...
Mechanical and Physical Performance of Concrete Including Waste Electrical Ca...
 
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
 

AASC-PlacedLargeColumn

  • 1. Cement and Concrete Research 29 (1999) 659–666 0008-8846/99/$–see front matter © 1999 Elsevier Science Ltd. All rights reserved. PII: S0008-8846(99) 00011- 3 Strength and shrinkage properties of alkali-activated slag concrete placed into a large column Frank Collins *, J.G. Sanjayan Department of Civil Engineering, Monash University, Wellington Road, Clayton, Victoria 3168, Australia Manuscript received 2 September 1998; accepted manuscript 11 January 1999 Abstract The properties of alkali-activated slag concrete (AASC) are generally determined on small-scale laboratory-produced prisms or cylinders. This investigation reports the in situ strength and in situ strain results from measurements on an 800 ϫ 800 ϫ 1200-mm column composed of AASC produced at a concrete plant. The results are contrasted with those of columns made with ordinary portland cement (OPC) and blended cement (50% OPC ϩ 50% slag) designated as GB50/50. For this type of AASC, the workability improved from the time of produc- tion to the time of concrete placement and minimal slump loss occurred over 2 hours (in contrast with OPC). The rate of in situ temperature development was similar to GB50/50, and slower than OPC; however, the maximum temperature difference between the interior and the ex- terior was considerably less than OPC and GB50/50. The in situ strength was identical to OPC and superior to GB50/50 at 28 and 91 days. Embedded strain gauges show small initial in situ expansion within the centre of the column followed by a rapid rate of tensile strain growth up to 14 days. At 91 days the differential strain between the centre of the column and the corner was sufficient to crack OPC concrete; how- ever, the AASC column remained uncracked. Possible explanations for this behaviour could be due to a greater tensile strain capacity of AASC than OPC concrete caused by greater creep and lower elastic modulus and higher tensile strength of AASC. © 1999 Elsevier Sci- ence Ltd. All rights reserved. Keywords: Curing; Compressive strength; Shrinkage; Alkali-activated cement; Granulated blast furnace slag 1. Introduction During construction, structural concrete typically re- ceives minimal curing following removal of formwork. Al- though the literature [1–11] reports the significant influence of curing on the strength development and drying shrinkage of alkali-activated slag concrete (AASC), the investigations generally involve testing of laboratory-size specimens. Whether lack of curing translates into a problem with larger scale structural concrete members is seldom reported. This paper reports the results of strength of cores and in situ measurements of shrinkage strains within an 800 ϫ 800 ϫ 1200-mm column, which are contrasted with measurements conducted on laboratory-size specimens. The strength of concrete containing AASC is sensitive to the curing environment. Talling and Brandstetr [1] report that loss of moisture during dry air storage reduces strength between 7 and 28 days. Kutti and colleagues [2] report 35% strength difference at 36 months age between prisms cured at 94% relative humidity (RH) compared with 33% RH. Following air storage at 95 and 70% RH, Talling [3] reports little difference in cylinder strength; however, when stored at 50% RH the strength development stops after 28 days and the strength at 91 days is 86% that of the same cylinders stored at 95% RH. Cylinders moist-cured for 7 days fol- lowed by 40% RH were 10.5% lower in compressive strength at 1 year compared with identical samples cured at 70% RH [4]. This is in contrast with Byfors [5], who re- corded similar strength when comparing water-cured strength vs. air-cured (50% RH) strength after initial 7 days wet cur- ing. Hakkinen [6] reports the same strength at 6 months age after 28 days of moist curing followed by exposure to 40% RH, as compared to identical samples exposed to 100% RH. After 1 day of curing at 40ЊC, cylinders subjected to 40% RH showed the same 1-year strength as identical samples subjected to 100% RH [7]. For alternating curing conditions (7 days 40% RH followed by 7 days Ͼ95% RHfor 10 cy- cles) Hakkinen [8] and Malalepszy and Deja [9] report sim- ilar and enhanced strength compared to cylinders stored at Ͼ95% RH. Sioulas [12] found that the in situ core strength of blended cement concretes (up to 70% slag) in large-scale columns is significantly less than that of ordinary portland cement (OPC) control concrete and up to 35% less than * Corresponding author. Tel.: 61-3-990-54959; Fax: 61-3-990-54944; E-mail: frank.collins@eng.monash.edu.au.
  • 2. 660 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 bath-cured cylinder strength. Hakkinen [8] showed that dry exposed AASC displays a size effect, whereby the strength of larger samples (up to 150-mm diameter cylinders) is less affected than smaller samples by surface microcracks devel- oped during drying. The in situ strength variations of a large structure member following exposed curing is unreported. Drying shrinkage strain of AASC is sensitive to the ex- posure environment, although there are differences in the reported magnitude. Kutti [2] found that for RH Ͼ 70% the drying shrinkage for AASC was similar to OPC. However, at RH 33% and RH 50% the drying shrinkage was 3.0 and 2.3 times the drying shrinkage of OPC. During bath curing AASC swells compared with OPC [4,10,11], whereas under exposure condition of 70% RH, AASC has 32% greater dry- ing shrinkage than OPC [4]. There are conflicting views on the reported long-term drying shrinkage. Douglas, Bilo- deau, and Malhotra [11] report higher drying shrinkage at 224 days (50% RH) for AASC than OPC concrete, whereas Hakkinen [6] and Kukko and Mannonen [7] found no sig- nificant difference after 500 days exposure at 40% RH be- tween AASC and OPC concrete for which the proportioning of constituents by weight was the same. The shrinkage be- haviour of AASC larger in size than laboratory prisms is un- reported. 2. Experimental programme 1 cubic meter of AASC mixture was made at a concrete plant and mixed in a 2-m3 agitator truck. A column 800 ϫ 800 mm in cross section and 1200 mm high was made, to- gether with samples for laboratory testing of strength and shrinkage under different curing conditions. In situ monitor- ing of the column has been conducted for temperature and ongoing strain using embedded thermocouples and vibrat- ing wire strain gauges. Strength has been monitored using extracted cores. The chemical composition and properties of the cementi- tious binders are summarised in Table 1. The binders used are ground granulated blast furnace slag (slag) and OPC. The term water/binder (w/b) ratio is used instead of water/ cement ratio to include all the binders mentioned above. The slag is supplied with gypsum (2% SO3), which is blended with the slag. The activators and adjuncts utilised were pow- dered sodium metasilicate and hydrated lime (L). The dry powdered silicate activator was preblended with the slag in the dry form prior to use for concrete manufacture. The hy- drated lime was added to the mix (1% weight of slag) as a 1:3 (hydrated lime:water) mixture to improve workability. The optimisation of the activator is not discussed in this paper. The coarse aggregate consisted of 14-mm maximum size basalt that has a specific gravity of 2.95 and 24-hour water absorption of 1.2%. The fine aggregate consisted of river sand that has a specific gravity of 2.65, 24-hour water ab- Table 1 Properties of cementitious materials Constituent/property Slag OPC SiO2 (%) 35.04 19.9 Al2O3 (%) 13.91 4.62 Fe2O3 (%) 0.29 3.97 MgO (%) 6.13 1.73 CaO (%) 39.43 64.27 Na2O (%) 0.34 TiO2 (%) 0.42 K2O (%) 0.39 0.57 P2O5 (%) Ͻ0.1 MnO (%) 0.43 Total sulphur as SO3 (%) 2.43 2.56 Sulphide Sulphur as S2Ϫ 0.44 Cl (p.p.m.) 80 Fineness (m2 /kg) 460 342 Loss on ignition (%) 1.45 2.9 Time to initial set (hours) N/A 2.0 Strength of 70 ϫ 70 ϫ 70 mm mortarcubes(MPa) 3 Days N/A 32.7 7 Days 42.0 28 Days 54.1 Table 2 Summary of concrete mixture proportions (per kg m3 ) Constituents OPC10 GB50/5010 AASC OPC 360 180 Slag 180 360 Free water 180 180 180 w/b 0.5 0.5 0.5 Fine aggregate 830 830 830 Coarse aggregate, 14 mm 1130 1130 1130 Air content % 0.5 1.2 1.2 Fig. 1. Steel formwork used to cast the column.
  • 3. F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 661 tions for OPC and blended cement (50% OPC ϩ 50% slag, GB50/50) mixes [12]. Allowance was made for moisture content in the aggregates, powdered sodium silicate activator, and hydrated lime slurry to ensure correct free water content in the mix. The development of activator optimisation and concrete mix design are reported in unpublished work. The batching sequence was as follows: 1. An initial 80-litre load of water was charged into the agitator truck using a metered pump. 2. 50% of the sand and coarse aggregate was then added. 3. The preblended slag and activator was hand-loaded. 4. The remaining sand and coarse aggregate was then loaded. 5. The hydrated lime slurry was then added, followed by increments of water to obtain the desired workability (100-mm design slump). The total time taken for the above steps was approximately 20 minutes. The travel time from the concrete plant to the concrete laboratory was 30 minutes. The configuration of the column formwork is shown in Fig. 1. The column was cast onto a 100-mm layer of poly- styrene, over which was a sheet of polythene plastic. The column was cast in three layers, as shown in Fig. 2. The pur- pose of the three layers was to assist the handling and trans- port of concrete for subsequent coring of each layer for Fig. 2. Elevation of column. Fig. 3. Layout of thermocouples (ϫ) and VWG strain gauges within cross section. sorption of 0.5%, and a fineness modulus of 2.19. Propor- tioning was for saturated and surface dry conditions. The concrete mixture proportions for AASC are sum- marised in Table 2. Also shown are reference mix propor-
  • 4. 662 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 strength testing. The layers were separated by wet corru- gated cardboard placed on either side of a masonite board. A 100-mm sacrificial layer, designed to negate the influ- ences of boundary bleed and temperature transfer, was al- lowed at each boundary separator. The lower sacrificial layer also served to accommodate instrumentation, as dis- cussed below. The formwork was removed 24 hours after concrete placement, and the column was stored at 22–25Њ C and 65–70% RH. A set of thermocouples and vibrating wire strain gauges (VWG) were installed within the lower sacrificial layer, as shown in Fig. 3. Type T copper/nickel thermocouples were installed along radial arms from the centre of the column, oriented at 90, 60, and 45Њ to the direction of the side face of the column. The spacing of thermocouples to the side face of a column were 0, 25, 50, 100, 200, and 400 mm. Another thermocouple was located immediately outside the column to ascertain ambient temperature variations. Readings were discontinued at 72 hours when the temperatures had equili- brated. In situ strain was measured by purpose-built embeddable VWG. The gauge length was 150 mm. The gauges were lo- cated at 25, 200, and 400 mm from the column face as well as at a corner, as shown in Fig. 3. The coring schedule is shown in Fig. 4. The core strengths at 28 and 91 days from the date of concrete placement are reported. Samples were also made for subsequent laboratory test- ing as follows: • Standard cylinders (100-mm diameter and 200-mm height) for compressive strength testing in triplicate at 1, 3, 7, 28, 56, 91 days, and 1 year (following demoul- ding, “bath” curing in Ca(OH)2 saturated water at 23ЊC, “exposed” curing at 23ЊC and 50% RH, and “sealed” curing involving storage in two polythene bags and a sealed container at 23ЊC). The sealed and exposed cur- ing environments were chosen to simulate curing ex- tremes within a large column. • Standard shrinkage prisms (75 ϫ 75 ϫ 285 mm) were made. The exposure conditions following demoulding for a triplicate set of samples were exposed, sealed, and followed AS1012, Part 13 (i.e., 7 days bath cured followed by exposed curing at 23ЊC and 50% RH). • Properties of fresh concrete such as slump and air con- tent were also determined. 2. Results 2.1. Fresh concrete properties The workability of the concrete improved from the time of first mixing at the concrete plant (100-mm slump) to the time of delivery (150-mm slump). This was also observed in the case of the laboratory mixes where the slump at 30 min- utes was better than the slump at the time of mixing. The slump loss over 2 hours was minimal. This can be explained by the slow dissolution of solid sodium silicate into the mix- Fig. 4. Coring schedule (coring ages shown in days).
  • 5. F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 663 ing water and that the sodium silicate acts as a water re- ducer. This is in contrast with other types of AASC whereby certain activator types can cause significant loss of work- ability. The air content of 1.2% was identical to the labora- tory prepared AASC. 2.2. In situ temperature development due to heat of hydration Fig. 5 shows the temperature development along ARM 45 (Fig. 3). Only ARM 45 is reported since it shows the greatest thermal gradient due to the biaxial cooling at the column corner. Fig. 5 shows lower rate of temperature rise and lower peak temperature at the centre of the column compared with an OPC column, as summarised in Table 3. AASC reached peak temperature at 18 hours, which was identical to GB50/50, although the temperature gradient was less. The dissolution of solid sodium silicate activator is a slow and endothermic process and this has contributed to the lower heat development of this activator type. This con- trasts with other types of activators that show more rapid re- action with slag [13]. 2.3. Compressive strength—standard cylinders The exposed and sealed curing conditions, as described above, were chosen to simulate the likely curing environ- ment at the outside and at the centre of the columns. The test results for AASC up to 91 days are summarised in Fig. 6. The 1-day strength was 17.5 MPa. There is a significant dif- ference in strength between samples subjected to exposed curing and sealed/bath curing. Beyond 28 days, the exposed concrete strength levels off whereas the sealed and bath cured cylinders show continued strength gain. At 28 days, AASC had 20 and 24% greater strength than GB50/50 concrete under bath and sealed curing, respec- tively. However, it was 9 and 3% lower in strength than OPC concrete. At 91 days, the compressive strength of AASC surpasses both OPC and GB50/50 concretes. 2.4. Compressive strength—extracted cores Figs. 7 and 8 show core strength vs. depth into the col- umn along ARM 45 at 28 and 91 days. The results are com- pared with those of OPC and GB50/50 concrete cores ob- tained from identical columns [12]. At 28 days AASC shows significantly higher in situ strength than GB50/50 concrete and almost identical in situ strength to the OPC column at the corner and at the centre. The trend is towards higher in situ strength near the centre of the column where the effects of drying are minimal. At 91 days the AASC shows a very small increase in the in situ strength (from 28 days) and shows the same trend as at 28 days, where the strength increases with depth into the concrete. The strength is very similar to OPC at all depths, with a slightly higher in situ strength at the centre of the col- umn. Both OPC and AASC show higher in situ strength than GB50/50 at 91 days, although the difference in strength is not as pronounced as at 28 days. The effects of drying at the corners, as opposed to at a single face, cause little difference in strength (4% lower at 28 days and 1% lower at 91 days). Horizontal cores (i.e., perpendicular to the direction of concrete placement) were drilled in the AASC column at 91 days. The core locations are shown in Fig. 4. The mean core strength was 39.0 MPa. The strengths are lower than the core strengths of samples drilled vertically at the corners, and this is most likely due to the fact that the strength of horizontally drilled cores is lower than that of cores drilled vertically with respect to the direction of casting [14–16]. The difference in strength between cores located at the corner and the centre of the column is shown in Table 4. De- spite no curing of the column exterior from day 1 on, the strength difference between the interior and the exterior of the column is not as pronounced as for the laboratory-exposed curing versus sealed curing. The laboratory-exposed curing environment for cylinders (23ЊC and 50% relative humid- ity) is more onerous than the in situ curing conditions expe- rienced by the column (22–25ЊC and 65–70% RH), as evi- denced by the strength results. The core strength at the centre of the column has identical strength at 28 days and 89% at 91 days to the sealed cured standard cylinders. The core strength at the centre of the column is 92 and 80% of Table 3 Temperature differences between the three column types Concrete type Peak temperature (ЊC) Time after casting (hours) Maximum centre to surface temperature difference (ЊC) AASC 41.5 18 10.5 OPC10 46.5 13.5 20.0 GB50/5010 36.5 18 15.0 Fig. 5. Temperature development within AASC column along ARM 45. Numbers in parentheses refer to thermocouple numbers shown in Fig. 3.
  • 6. 664 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 standard bath cured cylinders at 28 and 91 days, respec- tively. 2.5. Drying shrinkage Fig. 9 summarises the drying shrinkage results obtained according to AS1012, Part 13 (i.e., 7 days bath curing fol- lowed by exposed curing at 23ЊC and 50% RH), shrinkage following sealed curing, and also drying shrinkage following exposure from day 1. AASC shows minor expansions during the first 7 days, when bath and sealed cured, followed by a considerably higher rate of drying shrinkage when exposed. When exposed from day 1, the overall shrinkage strains are higher than the prisms tested to AS1012, Part 13, most likely due to the greater moisture loss during the first 7 days. 2.6. In situ strain development The VWG gauges located within the interior of the column show small expansions within the first few days (Fig. 10), as was also observed with measurements on laboratory prisms un- der sealed curing conditions (Fig. 9). Beyond 3 days, tensile strain develops rapidly and the differential shrinkage between the interior and the corner gauges is 71 microstrain at 12 days and 149 microstrain at 91 days. The total strains are less than the prisms, although this can be explained as a volume-to-area ratio effect. For OPC concrete this could lead to cracking be- cause concrete has a tensile strain capacity in the order of 70– 90 microstrain depending on the type of aggregate [17]. How- ever, apart from minor surface cracking, no major shrinkage- related cracking was visible. A possible explanation as to why cracking was not observed may be that the greater tensile strain capacity of AASC than OPC concrete caused by greater creep and lower elastic modulus, which is reported in a publication under review [18]. Another possible explanation is that the ten- sile strength of AASC may be higher than OPC, as evidenced by higher flexural strength than OPC concrete [18]. The com- bined effects of restraint, drying shrinkage, and creep are cur- rently under investigation. 3. Conclusions The results of this investigation indicate that: 1. For this type of AASC, which was based on a solid sodium silicate activator and produced at a concrete Fig. 6. Effect of curing on compressive strength of standard cylinders composed of AASC. Fig. 7. Summary of core strengths at 28 days. Fig. 8. Summary of core strengths at 91 days.
  • 7. F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 665 plant, workability improved from the time of produc- tion to the time of concrete placement (30 minutes) and showed minimal slump loss over 2 hours. 2. A column made with AASC based on solid sodium silicate activator reached the peak in situ temperature at 18 hours after casting. This was identical to GB50/ 50, whereas OPC concrete reached its peak tempera- ture at 13.5 hours. The maximum temperature differ- ence between the centre and exterior of the column was 10.5ЊC for AASC, whereas OPC and GB50/50 were 20ЊC and 15ЊC, respectively. 3. Laboratory-exposed (23ЊC and 50% RH) cylinders show considerable strength difference to sealed cured cylinders (31% at 91 days) and the strength develop- ment at ages beyond 28 days. 4. The in situ strength of AASC at 28 and 91 days is sim- ilar to those of OPC, with strength increasing towards the centre of the column where the effects of drying are minimal. The in situ strength is superior to that of GB50/50. The strength difference between the interior of the column and the exterior is 10%, which is consid- erably better than the laboratory-simulated conditions. 5. Measurements from embedded strain gauges showed small in situ expansions within the centre of the col- umn, which was also measured on laboratory prisms under sealed curing conditions. At 91 days the differ- ential strain between the centre of the column and the corner location was 149 microstrain. This would be sufficient to crack OPC concrete, whereas the AASC column remained uncracked. One possible explana- tion is that AASC has higher tensile strain capacity and also greater tensile strength than OPC concrete [18]. The combined effects of restraint, drying shrink- age, and creep are currently under investigation. Acknowledgments The financial support for this project is jointly provided by Independent Cement and Lime Pty Ltd., Blue Circle Southern Cement Ltd., and Australian Steel Mill Services. The authors thank the sponsors, especially Alan Dow, Tom Wauer, John Ashby, Kathryn Turner, Paul Ratcliff, and Dr. Ihor Hinczak for guidance and support. The efforts and as- sistance with the laboratory work provided by Jeff Doddrell and Peter Dunbar are also gratefully acknowledged. References [1] B. Talling, J. Brandstetr, Proceedings 3rd CANMET/ACI Int. Conf. on Fly Ash, Slag, and Natural Pozzolans in Concrete, Trondheim, Norway, ACI SP 114 (2) (1989) 1519. Table 4 Comparison of core strengths at the column corner and center with cylinder strengths Core strength (MPa) Cylinder strength (Mpa) Age Location AASC OPC GB50/50 Curing type AASC OPC GB50/50 28 days Corner (exterior) 40.5 39.5 27.5 Exposed 36.0 Not conducted Centre (interior) 44.5 46.5 35.0 Sealed 44.5 46.0 36.0 External face 42.0 46.0 32.5 Bath 48.5 53.0 40.5 91 days Corner (exterior) 40.5 44.0 34.0 Exposed 35.0 Not conducted Centre (interior) 45.0 43.5 41.5 Sealed 50.5 50.0 43.5 External face 42.5 44.0 38.0 Bath 56.0 54.0 52.5 Fig. 9. Shrinkage strains of standard prisms following exposure to different curing regimes (AASC).
  • 8. 666 F. Collins, J.G. Sanjayan/Cement and Concrete Research 29 (1999) 659–666 [2] T. Kutti, L. Berntsson, S. Chandra, Proceedings 4th CANMET/ACI Int. Conf. on Fly Ash, Slag, and Natural Pozzolans in Concrete, Istan- bul, Turkey, Supplementary Papers (1992) 615–625. [3] B. Talling, Proceedings 3rd CANMET/ACI Int. Conf. on Fly Ash, Slag, and Natural Pozzolans in Concrete, Trondheim, Norway, ACI SP 114 (2) (1989) 1485. [4] T. Hakkinen, Cem Concr Res 23 (2) (1993) 407. [5] K. Byfors, G. Klingstedt, V. Lehtonen, H. Pyy, L. Romben, Proceed- ings, ACI SP 114 (2) (1989) 1429. [6] T. Hakkinen, Techn. Res. Centre Finl. Res. Notes (1986) 540. [7] H. Kukko, R. Mannonen, Nord. Conc. Res., Publ. 1, Oslo, Nord. Conc. Fed. (1982) 16.1–16.16. [8] T. Hakkinen, Cem Concr Res 23 (3) (1993) 518. [9] J. Malalepszy, J. Deja, Sil Indust 11–12 (1988) 179. [10] P.M. Gifford, J.E. Gillott, Can J Civ Eng 24 (1996) 237. [11] E. Douglas, A. Bilodeau, V.M. Malhotra, ACI Mat J 89 (5) (1992) 509. [12] B. Sioulas, MEng Thesis, Dep. Civil Eng., Monash University, 1996. [13] F. Collins, J.G. Sanjayan, Cem Concr Res 28 (5) (1998) 655. [14] Concrete Core Testing for Strength, Concrete Society Technical Re- port No. 11, 1976. [15] Addendum (1987) to Concrete Core Testing for Strength, Concrete Society Technical Report No. 11, 1976. [16] A. Takahata, T. Iwashimizu, U. Ishibashi, Utilisation of High Strength Concrete—2nd Int. Symp., ACI SP 121 (1989) 741. [17] P. Bamforth, Digest No. 2, Concrete Society, UK, 1984. [18] F. Collins, J.G. Sanjayan, Cem Conc Res 29 (3) (1999) 455–458. Fig. 10. In situ strain development (VWG locations as shown in Fig. 3). VWG1, located at centre of column; VWG2, located 200 mm from centre; VWG3, located at outside face in middle; VWG4, at corner at edge.