SlideShare uma empresa Scribd logo
1 de 52
Baixar para ler offline
TI00365F/00/EN/15.12
71197996
Technical Information
Prosonic M FMU40/41/42/43/44
Ultrasonic Level Measurement
Compact transmitters for non-contact level measurement of fluids,
pastes and coarse bulk materials
Application
• Continuous, non-contact level measurement in fluids,
pastes, sullages and coarse bulk materials
• Flow measurement in open channels and measuring
weirs
• System integration via:
– HART (standard), 4 to 20mA
– PROFIBUS PA
– FOUNDATION Fieldbus
• Maximum measuring range:
– FMU40: 5 m (16 ft) in fluids,
2 m (6.6 ft) in bulk materials
– FMU41: 8 m (26 ft) in fluids,
3,5 m (11 ft) in bulk materials
– FMU42: 10 m (33 ft) in fluids,
5 m (16 ft) in bulk materials
– FMU43: 15 m (49 ft) in fluids,
7 m (23 ft) in bulk materials
– FMU44: 20 m (66 ft) in fluids,
10 m (33 ft) in bulk materials
Features and benefits
• Quick and simple commissioning via menu-guided on-
site operation with four-line plain text display;
7 languages selectable
• Envelope curves on the on-site display for simple
diagnosis
• Easy remote operation, diagnosis and measuring point
documentation with the free operating program
FieldCare supplied.
• Suitable for explosion hazardous areas
(Gas-Ex, Dust-Ex)
• Linearization function (up to 32 points) for conversion
of the measured value into any unit of length, volume
or flow rate
• Non-contact measurement method minimizes service
requirements
• Optional remote display and operation (up to 20 m
(66 ft) from transmitter)
• Installation possible from thread G 1½“ or 1½“ NPT
upwards
• Integrated temperature sensor for automatic
correction of the temperature dependent sound
velocity
Prosonic M
2 Endress+Hauser
Table of contents
Function and system design. . . . . . . . . . . . . . . . . . . . . 3
Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Equipment architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Load HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Output damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Linearization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Terminal compartment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Fieldbus plug connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Current consumption (2 wire instruments) . . . . . . . . . . . . . . . . 14
HART ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Max. noise HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Performance characteristics. . . . . . . . . . . . . . . . . . . . 15
Reaction time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Reference operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Measured value resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pulse frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Maximum measuring error . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Typical measuring error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Influence of the vapor pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installation variants FMU40, FMU41 . . . . . . . . . . . . . . . . . . . . . 16
Installation variants FMU42, FMU44 . . . . . . . . . . . . . . . . . . . . . 16
Installation variants FMU43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installation conditions for level measurements . . . . . . . . . . . . . . 17
Installation in narrow shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installation conditions for flow measurements . . . . . . . . . . . . . . . 18
Blocking distance, nozzle installation . . . . . . . . . . . . . . . . . . . . . 20
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Resistance to alternating temperature cycles . . . . . . . . . . . . . . . . 21
Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Ingress protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . 21
Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Process temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Process pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 22
Design; dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Housing design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Process connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Material (not in contact with process) . . . . . . . . . . . . . . . . . . . . . 26
Material (in contact with process) . . . . . . . . . . . . . . . . . . . . . . . . 27
Operability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Display and operating elements . . . . . . . . . . . . . . . . . . . . . . . . . 28
On-site operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Certificates and Approvals. . . . . . . . . . . . . . . . . . . . . 31
CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
External standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . 31
Ordering information. . . . . . . . . . . . . . . . . . . . . . . . . 32
Product structure FMU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Product structure FMU41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Product structure FMU42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Product structure FMU43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Product structure FMU44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5-point linearity protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Weather protection cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Installation bracket for FMU40, FMU41 . . . . . . . . . . . . . . . . . . . 41
Screw in flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Cantilever with mounting frame or wall bracket . . . . . . . . . . . . . 43
Commubox FXA195 HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Commubox FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
ToF Adapter FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Remote display FHX40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Operating manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Description of device functions . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Short instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Safety Instructions ATEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Safety Instructions NEPSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Control drawings, Installation drawings . . . . . . . . . . . . . . . . . . . 50
Prosonic M
Endress+Hauser 3
Function and system design
Measuring principle
A0019264
BD Blocking distance D Distance from sensor membrane - product surface
E Empty distance F Span (full distance)
L Level
Time-of-flight method
The sensor of the Prosonic M transmits ultrasonic pulses in the direction of the product surface. There, they
are reflected back and received by the sensor. The Prosonic M measures the time t between pulse transmission
and reception. The instrument uses the time t (and the velocity of sound c) to calculate the distance D between
the sensor membrane and the product surface:
D = c  t/2
As the device knows the empty distance E from a user entry, it can calculate the level as follows:
L = E - D
An integrated temperature sensor (NTC) compensates for changes in the velocity of sound caused by
temperature changes.
Interference echo suppression
The interference echo suppression feature on the Prosonic M ensures that interference echos (e.g. from edges,
welded joints and installations) are not interpreted as a level echo.
Calibration
Enter the empty distance E and the span F to calibrate the device.
Blocking distance
Span F may not extend into the blocking distance BD. Level echos within the blocking distance cannot be
evaluated due to the transient characteristics of the sensor.
20 mA
100%
4 mA
0%
D
L
F
E
BD
Sensor BD Max. range fluids Max. range bulk materials
FMU40 0.25 (0.8) 5 (16) 2 (6.6)
FMU41 0.35 (1.1) 8 (26) 3.5 (11)
FMU42 0.4 (1.3) 10 (33) 5 (16)
FMU43 0.6 (2.0) 15 (49) 7 (23)
FMU44 0.5 (1.6) 20 (66) 10 (33)
m (ft)
Prosonic M
4 Endress+Hauser
Equipment architecture 4…20 mA output with HART protocol
The complete measuring system consists of:
A0019266
1 PLC (programmable logic controller)
2 Commubox FXA191 (RS232) or FXA195 (USB)
3 Computer with operating tool (e.g. FieldCare)
4 Commubox FXA291 with ToF Adapter FXA291
5 Power supply (for 4-wire)
6 Prosonic with display and operating modul
7 Field Xpert SFX100
8 VIATOR Bluetooth modem with connection cable
9 Connection for Commubox FXA191, FXA195 or Field Xpert SFX100
10 Transmitter supply unit RMA422 or RN221N (communication resistor included)
If the HART communication resistor is not built into the supply unit, it is necessary to insert a communication
resistor of 250  into the 2-wire line.
On-site operation
• With display and operating module,
• With a Personal Computer, FXA291 with ToF Adapter FXA291 (USB) and the operating software
"FieldCare". FieldCare is a graphical operating software for instruments (radar, ultrasonic, guided
microimpulse). It assists with commissioning, securing data, signal analysis and documentation of the
measuring point.
Remote operation
• With Field Xpert SFX100
• With a Personal Computer, Commubox FXA195 and the operating software "FieldCare"
ENDRESS + HAUSER
E+–
%
ENDRESS + HAUSER
RMA 422
2
4
6789
10
5
1 3
Prosonic M
Endress+Hauser 5
System integration using PROFIBUS PA
A maximum of 32 transmitters (8 if mounted in an explosion hazardous location Ex ia IIC according to FISCO-
model) can be connected to the bus.The segment coupler provides the operating voltage to the bus. Both on-
site as well as remote operation are possible. For further information on the cable specifications, see Operating
Instructions BA00034S/04/ENGuidelines for planning and commissioning PROFIBUS DP/PA", PNO
Guideline 2.092 "PROFIBUS PA User and Installation Guideline" and IEC61158-2 (MBP).
A0019308
1 Computer with Profiboard/Proficard and operating tool (FieldCare)
2 PROFIBUS DP
3 PLC (programmable logic controller)
4 More functions (valves etc.)
5 Computer with operating tool (FieldCare)
6 Commubox FXA291 with ToF Adapter FXA291
7 Levelflex M
8 Prosonic M
9 Micropilot M with display and operating modul
10 PROFIBUS PA
11 Segment coupler
ENDRESS + HAUSERENDRESS + HAUSER
T
1 3
211
10
4
56
789
ENDRESS + HAUSER
E+–
%
Prosonic M
6 Endress+Hauser
System integration using FOUNDATION Fieldbus
A maximum of 32 transmitters (standard or Ex d) can be connected to the bus. For protection class Ex ia: the
maximum number of transmitters depends on the established rules and standards for intrinsically safe circuits
(EN 60070-14) and proof of instrinsic safety. Both on-site and remote operation are possible.
A0019309
1 SPS, PLC, API
2 Personal computer, e.g. with NI-FBUS configurator
3 VIATOR Bluetooth modem with connection cable
4 Field Xpert SFX100
5 More functions (valves etc.)
6 FieldCare
7 Commubox FXA291 with ToF Adapter FXA291
8 Levelflex M
9 Prosonic M
10 Micropilot M
11 Power conditioner
12 Power supply
13 FF link
14 FOUNDATION Fieldbus
15 Ethernet
T T
15
13 14
1
6
5
7
11
12
3 4
8910
2
Prosonic M
Endress+Hauser 7
System integration using Endress+Hauser Rackbus
You can interconnect a maximum of 64 2-wire devices with HART protocol to a Rackbus. Use an FXN672
interface module for each device. You can integrate this bus into a higher-level bus by using gateway.
A0019307
1 Interface FXN672
2 Personal computer with communication software
3 Bus
4 PLC
5 Gateway to MODBUS, FIP, PROFIBUS, INTERBUS etc.
6 4-20 mA HART
7 FieldCare
8 Commubox FXA291 with ToF Adapter FXA291
9 Levelflex M
10 Prosonic M
11 Micropilot M with display and operating modul
Note!
The FXN672 can be used with all 2-wire devices of the Prosonic M family.
FXN 671
mA1
+
FXN 671
mA1
+
FXN 671
mA1
+
ENDRESS + HAUSER
E+–
%
3
9
2 4
1
7
1011
8
5
6
Prosonic M
8 Endress+Hauser
System integration via Fieldgate
Vendor Managed Inventory
By using Fieldgates to interrogate tank or silo levels remotely, suppliers of raw materials can provide their
regular customers with information about the current supplies at any time and, for example, account for them
in their own production planning. For their part, the Fieldgates monitor the configured level limits and, if
required, automatically activate the next supply. The spectrum of options here ranges from a simple purchasing
requisition via e-mail through to fully automatic order administration by coupling XML data into the planning
systems on both sides.
Remote maintenance of measuring equipment
Fieldgates not only transfer the current measured values, they also alert the responsible standby personnel, if
required, via e-mail or SMS. In the event of an alarm or also when performing routine checks, service
technicians can diagnose and configure connected HART devices remotely. All that is required for this is the
corresponding HART operating software (e.g. FieldCare) for the connected device. Fieldgate passes on the
information transparently, so that all options for the respective operating software are available remotely. Some
on-site service operations can be avoided by using remote diagnosis and remote configuration and all others
can at least be better planned and prepared.
A0019306
The complete measuring system consists of devices and:
1 Fieldgate FXA520
2 Multidrop Connector FXN520
Note!
The number of instruments which can be connected in mutidrop mode can be calculated by the "FieldNetCalc"
program. A description of this program can be found in Technical Information TI00400F/00/EN
(Multidrop Conncector FXN520).
The program is available form your Endress+Hauser sales organisation or in the internet at: "www.endress.com
 select your country download search: Fieldnetcalc
-
ENDRESS+HAUSER
RN 221N
ENDRESS+HAUSER
RN 221N
.
20...45 VDC
FXN520FXN520
1 1 2
Prosonic M
Endress+Hauser 9
Input
Measured variable The distance D between the sensor membrane and the product surface is measured.
Using the linearization function, the device uses D to calculate:
• level L in any units
• volume V in any units
• Flow Q across measuring weirs or open channels in any units
Measuring range The measuring range is limited by the range of a sensor. The sensor range is, in turn, dependent on the
operating conditions. To estimate the actual range, proceed as follows (see also the calculation example in the
diagram):
1. Determine which of the influences shown in the following table are appropriate for your process.
2. Add the corresponding attenuation values.
3. From the total attenuation, use the diagram to calculate the range.
Fluid surface Attenuation
Calm 0 dB
Waves 5 to 10 dB
Strong turbulence (e.g. stirrers) 10 to 20 dB
Foaming Please contact your Endress+Hauser sales representative.
Bulk material surface Attenuation
Hard, rough (e.g. rubble) 40 dB
Soft (e.g. peat, dust-covered clinker) 40 to 60 dB
Dust Attenuation
No dust formation 0 dB
Little dust formation 5 dB
Heavy dust formation 5 to 20 dB
Filling curtain in detection range Attenuation
None 0 dB
Small quantities 5 to 10 dB
Large quantities 10 to 40 dB
Temperature difference between
sensor and product surface
Attenuation
to 20 °C (68 °F) 0 dB
to 40 °C (104 °F) 5 to 10 dB
to 80 °C (176 °F) 10 to 20 dB
Prosonic M
10 Endress+Hauser
A0019268
A Attenuation (dB)
R Range (m)
Example (for FMU43)
For typical solid applications, a certain amount of dust coverage is normally present. Therefore, the following
range results from the table and the diagram:
These measuring conditions have been taken into account during the calculation of the maximum measuring
range in solid applications.
Operating frequency
10 20 30 40 50 60 70 80
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
FMU44
A [dB]
R [m]
0
FMU43
FMU42
FMU41
FMU40
• Dust-covered rubble approx. 50 dB
• No dust formation 0 dB
• No filling curtain in
detection range 0 dB
• Temperature diff. < 20°C 0 dB
approx. 50 dB  range approx. 7 m (23 ft)
Sensor Operating frequency
FMU40 approx. 70 kHz
FMU41 approx. 50 kHz
FMU42 approx. 42 kHz
FMU43 approx. 35 kHz
FMU44 approx. 30 kHz
Prosonic M
Endress+Hauser 11
Output
Output signal According to the instrument version ordered:
• 4…20 mA with HART protocol
• PROFIBUS PA
• FOUNDATION Fieldbus
Signal on alarm Error information can be accessed via the following interfaces:
• On-site display (error symbol, error code and plain text description)
• Current output, signal on error can be selected (e.g. according to NAMUR recommendation NE43)
• Digital interface
Load HART Minimum load for HART communication: 250 
Output damping Freely selectable, 0 to 255 s
Linearization The linearization function of the Prosonic M allows conversion of the measured value into any unit of length
or volume. In open channels or measuring weirs, also a flow linearization is possible (calculation of the flow
from the measured level). The linearization table for calculating the volume in an horizontal cylindrical tank is
preprogrammed. You can also enter any number of other tables containing up to 32 value pairs either manually
or semi-automatically (by filling the vessel under controlled conditions).
The supplied FieldCare operating program can automatically calculate the table for any tank, weir or flume and
upload it into the device.
Flow curves for open channels can be calculated and entered into the instrument by the FieldCare as well
( ä 29, "Operation with FieldCare").
Prosonic M
12 Endress+Hauser
Power supply
Terminal compartment In the F12 housing, the terminals are located underneath the housing cover. In the T12 housing, they are under
the cover of the separate terminal compartment.
A0019271
A F12 housing
B T12 housing
1 Sealed terminal compartment
Terminal assignment
A0019268
A Loop-powered version 3 Plant ground
B 4-wire version (active) 4 4-20 mA HART
1 Power 5 Display unit, recorder, PCS
2 Test clamp for testing of the signal current
• Connect the connecting line to the screw terminals (line cross-sections of 0.5 to 2.5mm
(20 to 14 AWG))
in the terminal compartment.
• Use 2-wire twisted pair cable with screen for the connection.
• Protective circuitry against reverse polarity, RFI and over-voltage peaks is built into the device (see also
Technical Information TI00241F/00/EN "EMC Test Procedures")  ä 21, "Electromagnetic compatibility
(EMC)".
• A standard installation cable is sufficient if only the analogue signal is used. Use a screened cable when
working with a superimposed communication signal (HART).
1
A B
2
1
4
A B
3 3
1 2 3 4 5 6 1 2
L- L+ I+ I- I+ I- L1/L+ N/L-
4
1 5
Prosonic M
Endress+Hauser 13
The digital communication signal is transmitted to the bus via a 2-wire connection. The bus also provides the
auxiliary energy. Use 2-wire twisted pair cable with screen.
Refer to the following operating manuals for information on cable types, and how to set up and ground the
network:
• BA00034S "PROFIBUS DP/PA: "Guidelines for planning and commissioning PROFIBUS DP/PA", PNO
Guideline 2.092 "PROFIBUS PA User and Installation Guideline" and IEC61158-2 (MBP).
• BA00013S "FOUNDATION Fieldbus Overview", FONDATION Fieldbus Guideline and IEC61158-2 (MBP).
Fieldbus plug connectors For the versions with fieldbus plug connector (M12 or 7/8"), the signal line can be connected without opening
the housing.
Pin assignment of the M12 plug connector (PROFIBUS PA plug)
Pin assignment of the 7/8" plug connector (FOUNDATION Fieldbus plug)
Supply voltage HART, 2-wire
The following values are the voltages across the terminals directly at the instrument:
PROFIBUS PA
A0019276
1 T-Box
2 PROFIBUS PA
3 Plant ground
FOUNDATION Fieldbus
A0019275
3 41 2
+–
3
1
2
3 41 2
+–
3
A0011175
Pin Meaning
1 Signal +
2 not connected
3 Signal -
4 Ground
A0011176
Pin Meaning
1 Signal -
2 Signal +
3 Shield
4 Not connected
21
34
+
–
nc
2
1
4
3
Prosonic M
14 Endress+Hauser
HART, 4-wire, active
Terminals Cable cross-section: 0.5 to 2.5 mm2 (20 to 14 AWG)
Cable entry • Cable gland: M20x1.5 (recommended cable diameter 6 to 10 mm (0.24 to 0.39 in))
• Cable entry G ½" or NPT ½"
• PROFIBUS PA M12 plug
• FOUNDATION Fieldbus 7/8" plug
Power consumption
Current consumption
(2 wire instruments)
HART ripple 47 to 125 Hz: Vpp = 200 mV (measured at 500 )
Max. noise HART 500 Hz to 10 kHz: Vrms = 2.2 mV (measured at 500 )
Galvanic isolation With 4-wire devices, the evaluation electronics and mains voltage are galvanically isolated from each other.
Version
Current
consumption
Terminal voltage
minimum
Terminal voltage
maximum
2-wire HART
Standard
4 mA 14 V 36 V
20 mA 8 V 36 V
Ex ia
4 mA 14 V 30 V
20 mA 8 V 30 V
Ex d
4 mA 14 V 30 V
20 mA 11 V 30 V
Fixed current,
adjustable, e.g. for
solar power
operation
(measured value via
HART)
Standard 11 mA 10 V 36 V
Ex ia 11 mA 10 V 30 V
Fixed current for
HART multidrop
mode
Standard 4 mA1)
1) Start-up current 11 mA
14 V 36 V
Ex ia 4 mA1
14 V 30 V
Version Voltage Max. load
DC 10.5 to 32 V 600 
AC 50/60 Hz 90 to 253 V 600 
Version Power consumption
2-wire 51 mW to 800 mW
4-wire AC max. 4VA
4-wire DC; FMU40/41 330 mW to 830 mW
4-wire DC; FMU42/43 600 mW to 1 W
Communication Current consumption
HART 3.6 to 22 mA
PROFIBUS PA max. 13 mA
FOUNDATION Fieldbus max. 15 mA
Prosonic M
Endress+Hauser 15
Performance characteristics
Reaction time The reaction time depends on the parameter settings. The minimum values are:
• 2-wire devices (FMU40/41/42): min. 2 s
• 2-wire diveces (FMU43 - PROFIBUS PA or FOUNDATION Fieldbus): min. 2 s
• 2-wire devices (FMU44): min. 3 s
• 4-wire devices (FMU40/41/42/43/44): 0.5 s
Reference operating
conditions
• Temperature = +20 °C (+68 °F)
• Pressure = 1013 mbar abs. (15 psi abs.)
• Humidity = 50 %
• Ideal reflective surface (e.g. calm, smooth fluid surface)
• No interference reflections within signal beam
• Set application parameters:
– Tank shape = dome ceiling
– Medium property = liquid
– Process conditions = standard liquid
Measured value resolution
Pulse frequency • 2-wire devices (FMU40/41/42): max. 0.5Hz
• 2-wire devices (FMU43 - PROFIBUS PA or FOUNDATION Fieldbus): max. 0.5 Hz
• 2-wire devices (FMU44): max. 0.3 Hz
• 4-wire devices (FMU40/41/42/43/44): max. 2Hz
The exact values are dependent on the type of device and the parameter settings.
Maximum measuring error1) 2)
±0.2 % of the maximum span of the sensor
Typical measuring error Include linearity, repeatability and hysteresis
Better than:
Influence of the vapor
pressure
The vapor pressure at 20 °C (68 °F) gives a hint on the accuracy of the ultrasonic level measurement. If the
vapor pressure at 20 °C (68 °F) is below 50 mbar (1 psi), ultrasonic level measurement is possible with a very
high accuracy. This is valid for water, aqueous solutions, water-solid-solutions, dilute acids (hydrochloric acid,
sulfuric acid, ...), dilute bases (caustic soda, ...), oils, greases, slurries, pastes, ...
High vapor pressures or outgassing media (ethanol, acetone, ammonia, ...) can influence the accuracy. If
conditions like these are present, please contact your Endress+Hauser sales representative.
Sensor Measured value resolution
FMU40 1 mm (0.04 in)
FMU41 1 mm (0.04 in)
FMU42 2 mm (0.08 in)
FMU43 2 mm (0.08 in)
FMU44 2 mm (0.08 in)
1) according to EN 61298-2
2) with reference operating conditions
Sensor Measuring error
FMU40 ±2 mm (0.08 in) or 0.2 % of measuring distance*
FMU41 ±2 mm (0.08 in) or 0.2 % of measuring distance*
FMU42 ±4 mm (0.16 in) or 0.2 % of measuring distance*
FMU43 ±4 mm (0.16 in) or 0.2 % of measuring distance*
FMU44 ±4 mm (0.16 in) or 0.2 % of measuring distance*
* whichever is greater
Prosonic M
16 Endress+Hauser
Installation
Installation variants FMU40,
FMU41
A0019052
A Installation with counter nut
1 Counter nut (PC) supplied for G 1½" and G 2" instruments
B Installation with sleeve
1 Sealing (EPDM) supplied
C Installation with installation bracket
D Installation with screw in flange
1 Sealing (EPDM) supplied
2 Nozzle
3 Sensor
4 Screw in flange
For installation bracket or adapter flange  ä 41, "Accessories".
Installation variants FMU42,
FMU44
A0019280
A Installation with universal flange (Ex-hazardous, e.g. Zone 20)
B Installation with mounting bracket (Non-Ex-hazardous, Zone 20)
ENDRESS+HAUSER
Prosonic M
ENDRESS+HAUSER
Prosonic M
A B
C D
1
1
1
23
4
A B
- .
Prosonic M
Endress+Hauser 17
Installation variants FMU43
A0019053
A Installation with universal slip-on flange (option), (Ex-hazardous, e.g. Zone 20)
1 Sensor
2 Nozzle
3 Slip-on flange
B Installation with mounting bracket (Non-Ex-hazardous, Zone 20)
Installation conditions for
level measurements
A0019278
• Do not install the sensor in the middle of the tank (3). We recommend leaving a distance between the sensor
and the tank wall (1) measuring 1/6 of the tank diameter.
• Use a protective cover, in order to protect the device from direct sun or rain (2)  ä 41, "Weather
protection cover".
• Avoid measurements through the filling curtain (4).
• Make sure that equipment (5) such as limit switches, temperature sensors, etc. are not located within the
emitting angle . In particular, symmetrical equipment (6) such as heating coils, baffles etc. can influence
measurement.
• Align the sensor so that it is vertical to the product surface (7).
• Never install two ultrasonic measuring devices in a tank, as the two signals may affect each other.
• To estimate the detection range, use the 3 dB emitting angle .
ENDRESS+HAUSER
Prosonic M
13
2
A B
- .
2 3 4
1/6D
D
1
5
6 L
r
7
Sensor  Lmax rmax
FMU40 11° 5 (16) 0.48 (1.6)
FMU41 11° 8 (26) 0.77 (2.5)
FMU42 9° 10 (33) 0.79 (2.6)
FMU43 6° 15 (49) 0.79 (2.6)
FMU44 11 ° 20 (66) 1.93 (6.3)
m (ft)
Prosonic M
18 Endress+Hauser
Installation in narrow shafts
Installation conditions for flow
measurements
• Install the Prosonic M at the inflow side, as close above the maximum water level Hmax as possible (take into
account the blocking distance BD).
• Position the Prosonic M in the middle of the channel or weir.
• Align the sensor membrane parallel to the water surface.
• Keep to the installation distance of the channel or weir.
• You can enter the "Flow to Level" linearization curve ("Q/h curve") using FieldCare or manually via the on-
site display.
Example: Khafagi-Venturi flume
A0019606
A Khafagi-Venturi flume
B Inflow
C Outflow
BD Blocking distance
E Empty calibration
F Full calibration
V Direction of flow
In narrow shafts with strong interference echoes, we
recommend using an ultrasound guide pipe (e.g. PE
or PVC wastewater pipe) with a minimum diameter
of 100 mm (3.94 in).
Make sure that the pipe is not soiled by accumulated
dirt. If necessary, clean the pipe at regular intervals.
A0019310
1 Venting hole
1
1 x b0
b0
BD
A
E
B C
VHmax =F
Prosonic M
Endress+Hauser 19
Example: Triangular weir
A0019312
BD Blocking distance
E Empty calibration
F Full calibration
(= F)
min. 3 H
H
min. 2 H
a
min. 2 H
BD
E
max.
max.
max.
max.
Prosonic M
20 Endress+Hauser
Blocking distance,
nozzle installation
Install the Prosonic M at a height so that the blocking distance BD is not undershot, even at maximum fill level.
Use a pipe nozzle if you cannot maintain the blocking distance in any other way. The interior of the nozzle
must be smooth and may not contain any edges or welded joints. In particular, there should be no burr on the
inside of the tank side nozzle end. Note the specified limits for nozzle diameter and length. To minimise
disturbing factors, we recommend an angled socket edge (ideally 45°).
A0019311
A FMU40, FMU41
B FMU42, FMU44
C FMU43
BD Blocking distance F Full calibration (span)
SD Safety distance D Nozzle diameter
E Empty calibration L Nozzle length
Caution!
If the blocking distance is undershot, it may cause device malfunction.
Note!
In order to notice if the level approaches the blocking distance, you can specify a safety distance (SD). If the
level is within this safety distance, the Prosonic M outputs a warning or alarm message.
F
E
BD
SD
L
D
L
D
L
D
A B C
Maximum nozzle length [mm (in)]
Nozzle diameter FMU40 FMU41 FMU42 FMU43 FMU44
DN50/2" 80 (3.15)    
DN80/3" 240 (9.45) 240 (9.45) 250 (9.84)  
DN100/4" 300 (11.8) 300 (11.8) 300 (11.8) 300 (11.8) 
DN150/6" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
DN200/8" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
DN250/10" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
DN300/12" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
Sensor characteristics
Emitting angle  11° 11° 9° 6° 11°
Blocking distance [m (ft)] 0.25 (0.8) 0.35 (1.1) 0.4 (1.3) 0.6 (2.0) 0.5 (1.6)
Max. range [m (ft)]
in liquids
5 (16.0) 8 (26.0) 10 (33.0) 15 (49.0) 20 (66.0)
Max. range [m (ft)]
in solids
2 (6.6) 3.5 (11.0) 5 (16.0) 7 (23.0) 10 (33.0)
Prosonic M
Endress+Hauser 21
Environment
Ambient temperature –40 °C to +80 °C (–40 °F to +176 °F)
The functionality of the LC display becomes restricted at Tu<–20 °C (Tu<–4 °F) and Tu>+60 °C (Tu>140 °F).
If the device is operated outdoors in strong sunlight, you should use a protective cover ( ä 41).
Storage temperature –40 °C to +80 °C (–40 °F to +176 °F)
Resistance to alternating
temperature cycles
To DIN EN 60068-2-14; Nb test: +80°C/–40°C (+176 °F/–40 °F), 1K/min, 100cycles
Climate class DIN EN 60068-2-38 (Test Z/AD) DIN/IEC 68 T2-30Db
Ingress protection • With closed housing, tested according to
– IP68, NEMA 6P (24h at 1.83 m (6 ft) under water surface)
– IP66, NEMA 4x
• With open housing: IP20, NEMA 1 (also ingress protection of the display)
Caution!
Degree of protection IP68 NEMA 6P applies for M12 PROFIBUS-PA plugs and for 7/8" FF plug only when the
cable is plugged in.
Vibration resistance DIN EN 60068-2-64 / IEC 68-2-64: 20…2000 Hz, 1 (m/s
)2
/Hz; 3 x 100 min
Electromagnetic compatibility
(EMC)
• Electromagnetic compatibility according to all relevant requirements of the EN 61326- series and NAMUR
recommendation EMC (NE21). For details see declaration of conformity.
• A standard installation cable is sufficient if only the analogue signal is used. Use a screened cable when
working with a superimposed communication signal (HART).
Process
Process temperature –40°C to +80°C (–40 °F...+176 °F)
A temperature sensor is integrated in the sensor for correction of the temperature-dependent time-of-flight.
Process pressure • FMU40/41: 0.7 bar to 3bar abs. (10.15 psi...43.5 psi abs.)
• FMU42/43/44: 0.7 bar to 2.5bar abs. (10.15 psi...36.25 psi abs.)
Prosonic M
22 Endress+Hauser
Mechanical construction
Design; dimensions FMU40, FMU41
A0019317
A F12 housing B T12 housing
C FMU40 D FMU41
FMU42, FMU44 with slip-on flange
A0019318
A F12 housing B T12 housing
C FMU42 D FMU44
65
(2.6)
78
(3.1)
ø129(5.1)
~86 (3.4)
78
(3.1)
85
(3.3)
85
(3.3)
65
(2.6)
ø129(5.1)
162(6.4)
150(5.9)
68
(2.7)
~148(5.8)
~83(3.3)
22(0.9)
C D
ø39 (1.5)
ø50 (2.0)
~148(5.8)
~87(3.4)
22(0.9)
ENDRESS+HAUSER
Prosonic M ENDRESS+HAUSER
Prosonic M
32 (1.3)
A B
G 1½"
NPT 1½"
94
(3.7)
60 60
G 2"
NPT 2"
mm (in)
~110(4.3)
ø70 (2.8)
~85(3.3)
C
65
(2.6)
78
(3.1)
ø129(5.1)
86
(3.4)
78
(3.1)
85 (3.3)
65
(2.6)
ø129(5.1)
162(6.4)
150(5.9)
68
(2.7)
94
(3.7)
ENDRESS+HAUSER
Prosonic M ENDRESS+HAUSER
Prosonic M
32 (1.3)
A B
D
ø98 (3.9)
07(4.2)~1
~145(5.7)
85 (3.3)
mm (in)
Prosonic M
Endress+Hauser 23
FMU42, FMU44 with mounting bracket
A0019322
A FMU42 ( T12, F12 housing) B FMU44 (T12, F12 housing)
1 M8
FMU43
A0019337
A With slip-on flange (ANSI 4" DN 100) B With mounting bracket (F12 housing)
1 2xM8
Mounting bracket for FMU42, FMU43 and FMU44
A0019342
ENDRESS+HAUSER
Prosonic M
75
(3.0) 119 (4.7)
105(4.1)
A
ENDRESS+HAUSER
Prosonic M
B
119 (4.7)
30(1.2)
98 (3.9)
125(4.9)
30(1.2)
1 1
mm (in)
85 (3.3)
65
(2.6)
78
(3.1)
ø129(5.1)
150(5.9)
~248(9.8)
ENDRESS+HAUSER
Prosonic M
ø230 (9.1)
89 (3.5)
A B
~86
(3.4)
mm (in)
75(3.0)
158 (6.2)
1
11 (0.43)
119 (4.68)
2 (0.08)
25 (0.98)
120(4.7)
~123(4.8)
40 (1.6) 40 (1.6)
mm (in)
Prosonic M
24 Endress+Hauser
Flanges for FMU42 and FMU44
A0019343
Weight
suitable for A B C D E number of
boreholes
3" 150 lbs / DN80 PN16 / 10K 80 150 mm
(5.91")
160 mm
(6.30")
200 mm
(7.87")
19 mm
(0.75")
45° 8
4" 150 lbs / DN100 PN16 / 10K 100 175 mm
(6.90")
190.5 mm
(7.50")
228.6 mm
(9.00")
19 mm
(0.75")
45° 8
6" 150 lbs / DN150 PN16 / 10 K 150 240 mm
(9.45")
241.3 mm
(9.50")
285 mm
(11.22")
23 mm
(0.91")
45° 8
8" 150 lbs 298.5 mm
(11.75")
298.5 mm
(11.75")
342.9 mm
(13.50")
22. 5 mm
(0.89")
45° 8
DN200 PN16 / 10 K 200 290 mm
(11.42")
295 mm
(11.61")
340 mm
(13.39")
23 mm
(0.91")
30° 12
G 2"
ISO228
20(0.8)
C
E
A
B
D
mm (in)
Sensor Weight kg (lbs)
FMU40 approx. 2.5 (5.51)
FMU41 approx. 2.6 (5.73)
FMU42 approx. 3 (6.62)
FMU43 approx. 3.5 (7.72)
FMU44 approx. 4 (8.82)
Prosonic M
Endress+Hauser 25
Housing design Types of housings
• F12 housing with sealed terminal compartment for standard or Ex ia applications
• T12 housing with separate terminal compartment and explosionproof encapsulation
Material
Aluminium, powder-coated ( ä 26)
Cover
• Aluminium, for version without on-site display
• Inspection glass for version with on-site display. This version cannot be supplied together with the ATEX II
1/2 D certificate.
Process connection Sensor Process connection
FMU40 • Thread G 1½“
• Thread NPT 1½“ - 11.5
FMU41 • Thread 2"
• Thread NPT 2" - 11.5
FMU42 • Universal flange DN 80 PN16 / ANSI 3" 150 lbs / JIS 10K 80
• Universal flange DN 100 PN16 / ANSI 4" 150 lbs / JIS 10K 100
• Mounting bracket
FMU43 • Universal flange DN 100 / ANSI 4" / JIS16K100
• Mounting bracket
FMU44 • Universal flange DN 100 PN16 / ANSI 4" 150 lbs / JIS 10K 100
• Universal flange DN 150 PN16 / ANSI 6" 150 lbs / JIS 10K 150
• Universal flange DN200 PN16 / JIS 10K 200
• Flange ANSI 8" 150 lbs
• Mounting bracket
Prosonic M
26 Endress+Hauser
Material
(not in contact with process)
T12 and F12 housing (powder-coated)
A0019273
A T12 housing
B F12 housing
Note!
Seawater-resistant parts please order on request (complete in 316L (1.4404)).
A B
EN
DRESS+HAUSER
IP 65
Order Code:Ser.-No
.:
Messbereich
Measuring ran
ge
U 16...3
6 V DC
4...20
mA
ma
x. 20
m
MadeinGermanyMaulburg
T
>70°C :
A
t >85°C
MadeinGermanyMaulburg
EN
DRESS+HAUSER
IP 65
Order Code:
Ser.-No
.:
Mess
bereich
Measuring ran
ge
U 16...3
6 V DC
4...20
mA
ma
x. 20
m
MadeinGermanyMaulburg
T
>70°C :
A
t >85°C
987 5 6 98 5 6
3
2
1
4
2
1
3
3
7
Pos. Part Material
1 T12 and F12 housing AlSi10Mg
2
Cover (Display) AlSi10Mg
O-ring EPDM
Window ESG-K-Glass
Sealing of the glass Silicone sealing compound Gomastit 402
3
Cable gland Polyamid (PA), CuZn nickel-plated
O-Ring EPDM
Plug
PBT-GF30 or 1.0718 galvanized
PE or 3.1655
Adapter 316L (1.4435) or AlMgSiPb (anodized)
4
Cover (Connection compartment) AlSi10Mg
O-ring EPDM
Clamp Screw: A4; Clamp: CuZn nickel-plated; Spring washer: A4
5 O-ring EPDM
6
Tag 304 (1.4301)
Rope VA
Crimp sleeve Aluminium
7
Nameplate 304 (1.4301)
Groove pin A2
8 Ground terminal
Screw: A2; Springwasher: A4; Clamp: 304 (1.4301)
Holder: 301 (1.4310)
9 Screw A2-70
Prosonic M
Endress+Hauser 27
Material
(in contact with process)
A0019054
Note!
The chemical compatibility of the sensors must be checked before installation with compatibility charts.
Pos. Part A
FMU40, FMU41
B
FMU42, FMU44
C
FMU43
1 Sensor PVDF PVDF
UP (Unsaturated polyes-
ter resin)
2a Sealing EPDM EPDM or FKM EPDM
2b O-ring EPDM - EPDM
3 Flange -
PP, PVDF or stainless steel
316L (1.4435 or 1.4404) 1)
1) Endress+Hauser supplies DIN/EN flanges made of stainless steel AISI 316L with the material number 1.4404 or
1.4435. With regard to their temperature stability properties, the materials 1.4404 and 1.4435 are grouped under
13E0 in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical.
PP or 316 Ti (1.4571)
4 Counter nut PC - -
5 Screws - - V2A
6
Thread insert for
mounting bracket
- - CuZn
7 Sensor membrane - - 316 Ti (1.4571)
8
Mounting bracket (retainer)
Screws
-
-
316 Ti (1.4571)
V4A
-
-
9
Mounting bracket
Screws
-
-
316 Ti (1.4571)
V2A
316 Ti (1.4571)
V2A
1 2a
3
2a
3
1
1
6
5
9
7
2b
A B
C C
B
8
2a
4
2b
2a
Prosonic M
28 Endress+Hauser
Operability
Display and operating
elements
The LCD module VU331 for display and operation is located beneath the housing cover. The measured value
is legible through the glass in the cover. Open the cover to operate the device.
A0019274
1 LCD liquid crystal display
2 Snap fit
3 Keys
4 Symbols
Function of the keys
ENDRESS + HAUSER
E+–
1
2
3
4
Symbol in display
continuous flashing
Meaning Alarm Warning Communication Security Locking
Key(s) Meaning
O Navigate upwards in the selection list
Edit numeric value within a function
S Navigate downwards in the selection list
Edit numeric value within a function
X Navigate to the left within a function group
F Navigate to the right within a function group, confirmation.
O and F
or
S and F
Contrast settings of the LCD
O and Sand F
Hardware lock / unlock
After a hardware lock, an operation of the instrument via display or
communication is not possible!
The hardware can only be unlocked via the display. An unlock parameter must
be entered to do so (unlock parameter: 100).
Prosonic M
Endress+Hauser 29
On-site operation Operation with VU331
The LC-Display VU331 allows configuration via 3 keys directly at the instrument. All device functions can be
set through a menu system. The menu consists of function groups and functions. Within a function, application
parameters can be read or adjusted. The user is guided through a complete configuration procedure. For ease
operation can choose between 7 language: (de: german; en: english; es: spanish; fr: french; it: italian; ja:
japanese; nl: dutch).
L00-FMU4xxxx-07-00-00-en-004
Operation via Field Xpert SFX100
Compact, flexible and robust industry handheld terminal for remote parametrization and measured value
inspection via the HART current output or FOUNDATION Fieldbus. For details refer to Operating Instructions
BA00060S/04/EN.
Remote operation Operation with FieldCare
FieldCare is Endress+Hauser's FDT based Plant Asset Management Tool. It can configure all intelligent field
devices in your plant and supports you in managing them. By using status information, it also provides a simple
but effective means of checking their health. Hardware and software requirements you can find on the internet:
www.endress.com  select your country  search: FieldCare  FieldCare  Technical Data.
The FieldCare supports the following functions:
• Configuration of transmitters in online operation
• Signal analysis via envelope curve
• Tank linearization
• Loading and saving of instrument data (Upload/Download)
• Documentation of measuring point
Connection options
• HART with Commubox FXA195 and the USB port on a computer
• PROFIBUS PA via segment coupler and PROFIBUS interface card
• Commubox FXA291 with ToF Adapter FXA291 (USB) via service interface
X
X
X
X
S
S
OO FF
F
F
HOME
FG00 F000 F001 F002 F003 F004 ...
FG01
FG02
FG03
FG04
FG05
FG06
FG07
...
ENDRESS + HAUSER
E+–
Headline Position indicator
Main value UnitSymbol
Selection list
Function groups -> Functions
Help text
Envelope
curve
Prosonic M
30 Endress+Hauser
Menu-guided commissioning:
L00-FMU4xxxx-19-00-00-en-021
Signal analysis via envelope curve:
L00-FMU4xxxx-19-00-00-en-022
Prosonic M
Endress+Hauser 31
Operation with NI-FBUS Configurator (only FOUNDATION Fieldbus)
The NI-FBUS Configurator is an easy-to-use graphical environment for creating linkages, loops, and a schedule
based on the fieldbus concepts.
You can use the NI-FBUS Configurator to configure a fieldbus network as follows:
• Set block and device tags
• Set device addresses
• Create and edit function block control strategies (function block applications)
• Configure vendor-defined function and transducer blocks
• Create and edit schedules
• Read and write to function block control strategies (function block applications)
• Invoke Device Description (DD) methods
• Display DD menus
• Download a configuration
• Verify a configuration and compare it to a saved configuration
• Monitor a downloaded configuration
• Replace devices
• Save and print a configuration
Certificates and Approvals
CE mark The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms the
instrument passing the required tests by attaching the CE-mark.
Ex approval The available certificates are listed in the ordering information. Note the associated safety instructions (XA) and
control or installation drawings (ZD).
External standards and
guidelines
EN 60529
Protection class of housing (IP-code)
EN 61326 series
EMC product family standard for electrical equipment for measurement, control and laboratory use
NAMUR
User association for automation technology in process industries
Prosonic M
32 Endress+Hauser
Ordering information
Product structure FMU40 Versions that mutually exclude one another are not marked.
010 Certificates
A Variant for non-hazardous area
E NEPSI Ex nA II T6
G ATEX II 3G Ex nA IIC T6
I NEPSI Ex ia IIC T6
J NEPSI Ex d(ia) IIC T6
K TIIS Ex ia II C T6
N CSA General Purpose
Q NEPSI DIP
S FM IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2
T FM XP Cl. I,II,III Div. 1 Gr. A-G
U CSA IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2
V CSA XP Cl. I,II,III Div. 1 Gr. A-G
1 ATEX II 1/2G Ex ia IIC T6
2 ATEX II 1/2D, Alu blind cover
4 ATEX II 1/2G Ex d (ia) IIC T6
5 ATEX II 1/3D
6 ATEX II 3D Ex t IIIC T* °C Dc
Y Special certificate
020 Process connection
R G 1½“ threadISO 228
N NPT 1½“ - 11,5 thread
Y Special version
030 Power supply/communication
B 2 wire, 4...20mA-loop/HART
H 4 wire, 10,5...32VDC / 4-20mA HART
G 4 wire, 90...253VAC / 4-20mA HART
D 2 wire, PROFIBUS PA
F 2 wire, FOUNDATION Fieldbus
J 2-wire; 4-20mA HART, 5-point linearity protocol
K 2-wire; PROFIBUS PA, 5-point linearity protocol
L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol
M 4-wire 90-250VAC; 4-20mA HART,5-point linearity protocol
N 4-wire 10.5-32VDC;4-20mA HART,5-point linearity protocol
Y Special version
040 Display / on-site operation
1 Without LC display
2 With LC display VU331 incl. on-site operation
3 Prepared for remote display FHX 40
9 Special version
050 Housing
A Aluminium F12 housing coated to IP68 NEMA6P
C Aluminium T12 housing coated to IP68 NEMA6P; with separate terminal compartment
D Aluminium T12 housing coated to IP68 NEMA6P+OVP; with separate terminal
compartment; with overvoltage protection
9 Special version
Prosonic M
Endress+Hauser 33
060 Screw union/entry
2 M20x1.5 screw union
3 G 1/2“ entry
4 NPT 1/2“ entry
5 M12 PROFIBUS-PA plug-in connector
6 7/8" FF plug
9 Special version
995 Marking
1 Tagging (TAG)
2 Bus address
FMU40 - Product designation
Prosonic M
34 Endress+Hauser
Product structure FMU41 010 Certificates
A Variant for non-hazardous area
E NEPSI Ex nA II T6
G ATEX II 3G Ex nA IIC T6
I NEPSI Ex ia IIC T6
J NEPSI Ex d(ia) IIC T6
K TIIS Ex ia IIC T6
N CSA General Purpose
Q NEPSI DIP
S FM IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl.I Div.2, zone 0,1,2
T FM XP Cl. I,II,III Div. 1 Gr. A-G / zone 1,2
U CSA IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2, zone 0,1,2
V CSA XP Cl. I,II,III Div. 1 Gr. A-G / zone 1,2
1 ATEX II 1/2G Ex ia IIC T6
2 ATEX II 1/2D, Alu blind cover
4 ATEX II 1/2G Ex d (ia) IIC T6
5 ATEX II 1/3D
6 ATEX II 3D Ex t IIIC T* °C Dc
Y Special certificate
020 Process connection
R G 2“ threadISO 228
N NPT 2“ - 11,5 thread
Y Special version
030 Power supply/communication
B 2 wire, 4...20mA-loop/HART
H 4 wire, 10,5...32VDC / 4-20mA HART
G 4 wire, 90...253VAC / 4-20mA HART
D 2 wire, PROFIBUS PA
F 2 wire, FOUNDATION Fieldbus
J 2-wire; 4-20mA HART, 5-point linearity protocol
K 2-wire; PROFIBUS PA, 5-point linearity protocol
L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol
M 4-wire 90-250VAC; 4-20mA HART,5-point linearity protocol
N 4-wire 10.5-32VDC;4-20mA HART,5-point linearity protocol
Y Special version
040 Display / on-site operation
1 Without LC display
2 With LC display VU331 incl. on-site operation
3 Prepared for remote display FHX 40
9 Special version
050 Housing
A Aluminium F12 housing coated to IP68 NEMA 6P
C Aluminium T12 housing coated to IP68 NEMA 6P; with separate terminal compartment
D Aluminium T12 housing coated to IP68 NEMA 6P; with separate terminal compartment;
with overvoltage protection
9 Special version
060 Screw union/entry
2 M20x1.5 screw union
3 G 1/2“ entry
4 NPT 1/2“ entry
5 M12 PROFIBUS-PA plug-in connector
6 7/8" FF plug
9 Special version
995 Marking
1 Tagging (TAG)
2 Bus address
FMU41 - Product designation
Prosonic M
Endress+Hauser 35
Product structure FMU42 010 Certificates
A Variant for non-hazardous area
E NEPSI Ex nA II T6
G ATEX II 3G Ex nA IIC T6
I NEPSI Ex ia IIC T6
J NEPSI Ex d (ia) IIC T6
K TIIS Ex ia II C T6 (in preparation)
N CSA General Purpose
Q NEPSI DIP
S FM IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2
T FM XP Cl. I,II,III Div. 1 Gr. A-G
U CSA IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2
V CSA XP Cl. I,II,III Div. 1 Gr. A-G
1 ATEX II 1/2 G Ex ia IIC T6
2 ATEX II 1/2 D, Alu blind cover
4 ATEX II 1/2 G Ex d [ia] IIC T6
5 ATEX II 1/3D
6 ATEX II 3D Ex t IIIC T* °C Dc
Y Special certificate
020 Process connection
M Mounting bracket FAU20
P UNI flange 3"/DN80/80, PP, max. 2.5bar abs./ 36psia
suitable for 3" 150lbs / DN80 PN16 / 10K 80
Q UNI flange 3"/DN80/80, PVDF, max. 2.5bar abs./ 36psia
suitable for 3" 150lbs / DN80 PN16 / 10K 80
S UNI flange 3"/DN80/80, 316L, max. 2.5bar abs./ 36psia
suitable for 3" 150lbs / DN80 PN16 / 10K 80
T UNI flange 4"/DN100/100, PP, max. 2.5bar abs./ 36psia
suitable for 4" 150lbs / DN100 PN16 / 10K100
U UNI flange 4"/DN100/100, PVDF, max. 2.5bar abs./ 36psia
suitable for 4" 150lbs / DN100 PN16 / 10K100
V UNI flange 4"/DN100/100, 316L, max. 2.5bar abs./ 36psia
suitable for 4" 150lbs / DN100 PN16 / 10K100
Y Special version
030 Power supply/communication
B 2 wire, 4...20mA-loop/HART
H 4 wire, 10,5...32VDC / 4-20mA HART
G 4 wire, 90...253VAC / 4-20mA HART
D 2 wire, PROFIBUS PA
F 2 wire, FOUNDATION Fieldbus
J 2-wire; 4-20mA HART, 5-point linearity protocol
K 2-wire; PROFIBUS PA, 5-point linearity protocol
L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol
M 4-wire 90-250VAC; 4-20mA HART,5-point linearity protocol
N 4-wire 10.5-32VDC;4-20mA HART,5-point linearity protocol
Y Special version
040 Display / on-site operation
1 Without LC display
2 With LC display VU331 incl. on-site operation
3 Prepared for remote display FHX40
9 Special version
050 Housing
A Aluminium F12 housing coated to IP68 NEMA 6P
C Aluminium T12 housing coated to IP68 NEMA 6P, with separate terminal compartment
D Aluminium T 12 housing coated to IP68 NEMA 6P, with separate terminal
compartment; with overvoltage protection
Y Special version
060 Gland/Entry
2 M20x1.5 gland
3 G 1/2“ entry
4 NPT 1/2“ entry
Prosonic M
36 Endress+Hauser
5 M12 PROFIBUS-PA plug
6 7/8" FF plug
9 Special version
070 Sealing Sensor/Flange
2 VITON flat sealing
3 EPDM flat sealing
9 special version
080 Additional options
A Additional options not selected
995 Marking
1 Tagging (TAG)
2 Bus address
FMU42 - Product designation
060 Gland/Entry
Prosonic M
Endress+Hauser 37
Product structure FMU43 010 Certificates
A Variant for non-hazardous area
2 ATEX II 1/2D, Alu blind cover
5 ATEX II 1/3D
6 ATEX II 3D Ex t IIIC T* °C Dc
M FM DIP Cl.II Div.1 Gr.E-G, NI Cl.I Div.2, Zone 2
N CSA General Purpose
P CSA DIP Cl.II Div.1 Gr.E-G, NI Cl.I Div.2, zone 2
Q NEPSI DIP
Y Special version
020 Process connection/material
P Flange DN 100/ANSI 4"/JIS 16K100, PP (universal slip-on flange included)
S Flange DN 100/ANSI 4"/JIS 16K100, SS 316TI (universal slip-on flange included)
K Without slip-on flange/without mounting bracket (customer mounting equipment)
M With mounting bracket FAU20
Y Special version
030 Power supply/communication
H 4 wire, 10,5...32VDC / 4-20mA HART
G 4 wire, 90...253VAC / 4-20mA HART
D 2 wire, PROFIBUS PA
F 2 wire, FOUNDATION Fieldbus
J 2-wire; 4-20mA HART, 5-point linearity protocol
K 2-wire; PROFIBUS PA, 5-point linearity protocol
L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol
M 4-wire 90-250VAC; 4-20mA HART, 5-point linearity protocol
N 4-wire 10.5-32VDC;4-20mA HART, 5-point linearity protocol
Y Special version
040 Display / on-site operation
1 Without LC display
2 4-line display VU331, Envelope curve display on site
3 Prepared for remote display FHX 40
9 Special version
050 Housing
A Aluminium F12 housing coated to IP68 NEMA 6P
9 Special version
060 Screw union/entry
2 M20x1.5 screw union
3 G 1/2“ entry
4 NPT 1/2“ entry
5 M12 PROFIBUS-PA plug-in connector
6 7/8" FF plug
9 Special version
995 Marking
1 Tagging (TAG)
2 Bus address
FMU43 - Product designation
Prosonic M
38 Endress+Hauser
Product structure FMU44 010 Approval
A Non-hazardous area
1 ATEX II 1/2G Ex ia IIC T6
4 ATEX II 1/2G Ex d (ia) IIC T6
G ATEX II 3G Ex nA IIC T6 Gc
2 ATEX II 1/2 D, Alu blind cover
5 ATEX II 1/3 D
6 ATEX II 3D Ex t IIIC T* °C Dc
S FM IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.I Div.2, Zone 0,1,2 (in preparation)
T FM XP Cl.I,II,III Div.1 Gr.A-G, Zone 1,2 (in preparation)
N CSA General Purpose
U CSA IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.I Div.2, zone 0,1,2
V CSA XP Cl.I,II,III Div.1 Gr.A-G
K TIIS Ex ia IIC T6 (in preparation)
I NEPSI Ex ia IIC T6 (in preparation)
J NEPSI Ex d(ia) IIC T6 (in preparation)
E NEPSI Ex nA II T6 (in preparation)
Q NEPSI DIP (in preparation)
Y Special version, to be specified
020 Process connection
A 8" 150lbs FF, 316L, max 2.5bar abs./36psia
E UNI flange 6"/DN150/150, PP, max 2.5bar abs./ 36psia,
suitable for 6" 150lbs / DN150 PN16 / 10K 150
F UNI flange 6"/DN150/150, PVDF, max 2.5bar abs./36psia,
suitable for 6" 150lbs /DN150 PN16 / 10K 150
G UNI flange 6"/DN150/150, 316L, max 2.5bar abs. 36psia,
suitable for 6" 150lbs / DN150 PN16 / 10K 150
H UNI flange DN200/200, PP, max 2.5bar abs./ 36 psia,
suitable for DN200 PN16 / 10K 200
J UNI flange DN200/200, PVDF, max 2.5bar abs./ 36psia,
suitable for DN200 PN16 / 10K 200
K UNI flange DN200/200, 316L, max 2.5bar abs./ 36psia,
suitable for DN200 PN16 / 10K 200
L 8" 150lbs FF, PP, max 2.5bar abs./ 36psia
M Mounting bracket FAU20
N 8" 150lbs FF, PVDF, max 2.5bar abs./ 36psia
T UNI flange 4"/DN100/100, PP, max 2.5bar abs./ 36psia,
suitable for 4" 150lbs / DN100 PN16 / 10K 100
U UNI flange 4"/DN100/100, PVDF, max. 2.5bar abs./ 36 psia,
suitable for 4" 150lbs / DN100 PN16 / 10K 100
V UNI flange 4"/DN100/100, 316L, max 2.5bar abs./ 36psia,
suitable for 4" 150lbs / DN100 PN16 / 10K 100
Y Special version, to be specified
030 Power supply; Output
B 2-wire; 4-20mA HART
D 2-wire; PROFIBUS PA
F 2-wire; FOUNDATION Fieldbus
G 4-wire 90-250VAC; 4-20mA HART
H 4-wire 10.5-32VDC; 4-20mA HART
J 2-wire; 4-20mA HART, 5-point linearity protocol
K 2-wire; PROFIBUS PA, 5-point linearity protocol
L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol
M 4-wire 90-250VAC; 4-20mA HART, 5-point linearity protocol
N 4-wire 10.5-32VDC;4-20mA HART, 5-point linearity protocol
Y Special version, to be specified
040 Operation
1 w/o display, via communication
2 4-line display VU331, Envelope curve display on site
3 Prepared for FHX40, Remote display (accessory)
9 Special version, to be specified
FMU44 - product designation, part 1
Prosonic M
Endress+Hauser 39
050 Housing
A F12 Alu, coated IP68 NEMA6P
C T12 Alu, coated IP68 NEMA6P, Separate conn. compartment
D T12 Alu, coated IP68 NEMA6P + OVP, Sep. conn. compartment, OVP = overvoltage
protection
9 Special version, to be specified
060 Cable entry
2 Gland M20 (Ex d > thread M20)
3 Thread G1/2
4 Thread NPT 1/2
5 Plug M12
6 Plug 7/8“
9 Special version, to be specified
070 Process Sealing Sensor/ Flange
2 Viton
3 EPDM
9 Special version, to be specified
080 Additional option
A Basic version
Y Special version, to be specified
995 Marking
1 Tagging (TAG)
2 Bus address
FMU44 - complete product designation
Prosonic M
40 Endress+Hauser
5-point linearity protocol The following must be taken into account if option "5 point linearity protocol" has been selected:
• The five points of the linearity protocol are evenly distributed across the measuring range (0 % to 100 %). In
order to define the measuring range, Empty calibration (E) and Full calibration (F) have to be specified.3)
• The following restrictions have to be taken into account when defining E and F:
A0019522
Note!
The linearity is checked under reference conditions.
Scope of delivery • Instrument according to the version ordered
• Endress+Hauser operating program on the enclosed CD-ROM
• Brief operating instructions according to the communication version
• For certified instrument versions: Safety Instructions, Control- or Installation drawings
• For FMU40 *R**** and FMU41 *R****: counter nut (PC)
• For FMU40/41: sealing ring (EPDM)
• For gland M20x1.5:
– 1 cable gland for 2-wire instruments
– 2 cable glands for 4-wire instruments
The cable glands are mounted on delivery.
• CD-ROM with further documentation, e.g. Operating Instructions, Description of Intrument Functions
3) If the values for the full calibration and empty calibration are missing or outside the specified area, the devices are tested with the maximum value according
to the table.
Pos. Measuring range FMU40 FMU41 FMU42 FMU43 FMU44
E Maximum value for the empty calibration 5000 (197) 8000 (315) 10000 (394) 15000 (591) 20000 (787)
F Maximum value for the full calibration 4750 (187) 7500 (295) 9600 (378) 14400 (567) 19500 (768)
S Minimum span E-F 100 (3.94) 100 (3.94) 100 (3.94) 150 (591) 250 (9.84)
A Minimum distance between reference
point R from sensor and 100 % level
250 (9.84) 500 (19.7) 400 (15.7) 600 (23.6) 500 (19.7)
mm (in)
R
AF
mm (in)
E
S
Prosonic M
Endress+Hauser 41
Accessories
Weather protection cover A Weather protection cover made of stainless steel is recommended for outdoor mounting. The shipment
includes the protective cover and tension clamp.
A0019345
A F12 housing, T12 housing
Installation bracket for
FMU40, FMU41
A0019346
MadeinGermanyMaulburgMadeinGermanyMaulburg
A
70
(2.76)
mm (in)
240 (9.45)
135 (5.31)
95(3.74)
45°
Part Order No. Material
Protective cover, tension clamp
543199-0001
304 (1.4301)
Screw, nut, disk A2
Sensor Order No. Material Weight
FMU40, G 1½" 942669-0000
316 Ti (1.4571) 3.4 kg (7.5 lbs)
FMU41, G 2" 942669-0001
Suited for NPT 1½" and 2" as well
400 (15.7) 120 (4.72)
120
(4.72)
30(1.2)
250(9.84)
G
ø16 (0.6)
3 (0.12)
mm (in)
Prosonic M
42 Endress+Hauser
Screw in flange
A0019281
1 Screw in flange
2 Nozzle
3 Sensor
4 Sealing ring EPDM (supplied)
Screw in flange FAX50
4 1
3 2
015 Material:
BR1 DN50 PN10/16 A, steel flange EN1092-1
BS1 DN80 PN10/16 A, steel flange EN1092-1
BT1 DN100 PN10/16 A, steel flange EN1092-1
JF1 2" 150lbs FF, steel flange ANSI B16.5
JG1 3" 150lbs FF, steel flange ANSI B16.5
JH1 4" 150lbs FF, steel flange ANSI B16.5
JK2 8" 150lbs FF, PP max 3bar abs/44psia flange ANSI B16.5
XIF UNI flange 2"/DN50/50, PVDF max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50
XIG UNI flange 2"/DN50/50, PP max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50
XIJ UNI flange 2"/DN50/50, 316L max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50
XJF UNI flange 3"/DN80/80, PVDF max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80
XJG UNI flange 3"/DN80/80, PP max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80
XJJ UNI flange 3"/DN80/80, 316L max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80
XKF UNI flange 4"/DN100/100, PVDF max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100
XKG UNI flange 4"/DN100/100, PP max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100
XKJ UNI flange 4"/DN100/100, 316L max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100
XLF UNI flange 6"/DN150/150, PVDF max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150
XLG UNI flange 6"/DN150/150, PP max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150
XLJ UNI flange 6"/DN150/150, 316L max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150
XMG UNI flange DN200/200, PP max 4bar abs/58psia, suitable for DN200 PN16/10K 200
XNG UNI flange DN250/250, PP max 4bar abs/58psia, suitable for DN250 PN16/10K 250
YYY Special version
020 Sensor Connection:
A Thread ISO228 G3/4
B Thread ISO228 G1
C Thread ISO228 G1-1/2
D Thread ISO228 G2
E Thread ANSI NPT3/4
F Thread ANSI NPT1
G Thread ANSI NPT1-1/2
H Thread ANSI NPT2
Y Special version
015 020
FAX50 -
Prosonic M
Endress+Hauser 43
Cantilever with mounting
frame or wall bracket
A0019523
A Installation with cantilever and wall bracket
B Installation with cantilever and mounting frame
1 Cantilever
2 Mounting frame
3 Wall bracket
Cantilever
A0019349
• The 50 mm (1.97 in) or 62 mm (2.44 in) orifices serve for the mounting of the FMU40 or FMU41 sensor,
respectively.
• The 22 mm (0.87 in) orifice may be used for an additional sensor.
Fixing screws are supplied.
ENDRESS+HAUSER
ProsonicM
ENDRESS+HAUSER
ProsonicM
3
1
2
A B
1
A B C D Weight for Sensor Material Order Code
585 (23) 250 (9.84) 2 (0.08) 200 (7.87) 1.9 kg
(4.2 lbs)
FMU40 316Ti (1.4571) 52014132
galv. steel 52014131
FMU41 316Ti (1.4571) 52014136
galv. steel 52014135
1085 (42.7) 750 (29.5) 3 (0.12) 300 (11.8) 4.4 kg
(9.7 lbs)
FMU40 316Ti (1.4571) 52014134
galv. steel 52014133
FMU41 316Ti (1.4571) 52014138
galv. steel 52014137
mm (in)
A
D
M8
35 (1.4)
50(2.0)
20(0.8)
105(4.1)
50/62
(2.0/2.4)
22(0.9)
C
C
6.5(0.3)
15(0.6)
100(3.9)
25(1.0)
35 (1.4)100 (3.9)75 (2.9) B
20(0.8)
75 (2.9)
mm (in)
Prosonic M
44 Endress+Hauser
Mounting Frame
A0019279
Wall Bracket
A0019350
Height Material Weight Order Code
700 (27.6) galv. steel
3.2 kg (7.06 lbs)
919791-0000
700 (27.6) 316Ti (1.4571) 919791-0001
1400 (55.1) galv. steel
4.9 kg (10,08 lbs)
919791-0002
1400 (55.1) 316Ti (1.4571) 919791-0003
mm (in)
Material Weight Order Code
galv. steel
1.4 kg (3.09 lbs)
919792-0000
316Ti (1.4571) 919792-0001
3.2 (0.13)
20 (0.8)
55 (2.17)
100(3.94)
25(0.98)
700/1400
(27.6/55.1)
45(1.77)
76
(2.99)
100
(3.94)
200(7.87)
13(0.5)
ø33.7 (1.3)
130 (5.12)
150 (5.91)
100
(3.94)
60 (2.36)
4 (0.16)
6.5(0.3)mm (in)
110 (4.3)
25 (1.0)
5 (0.2)
6.5 (0.3)
150 (5.9)
ø33.7 (1.3)
3.2 (0.1)
110(4.3)
13(0.5)
150(5.9)
180(7.1)
~213(8.4)
~ (3.5)88
mm (in)
Prosonic M
Endress+Hauser 45
Commubox FXA195 HART For intrinsically safe communication with FieldCare via the USB interface.
For details refer to TI00404F/00/EN.
Commubox FXA291 The Commubox FXA291 connects Endress+Hauser field instruments via the service interface to the USB
interface of a personal computer or a notebook. For details refer to TI00405C/07/EN.
Note!
For the instrument you need the "ToF Adapter FXA291" as an additional accessory.
ToF Adapter FXA291 The ToF Adapter FXA291 connects the Commubox FXA291 via the USB interface of a personal computer or
a notebook to the instrument. For details refer to KA00271F/00/A2.
Remote display FHX40
A0019277
A Wall mounting (without mounting bracket)
B Pipe mounting (mounting bracket and plate supplied optionally, see product structure)
1 Prosonic M, Levelflex M, Micropilot M
2 Separate housing FHX40 (IP65)
3 Cable
4 Pipe
For the device families Micropilot FMR2xx, Levelflex FMP4x and Prosonic FMU4x, the remote display FHX40
must be only used for the HART communication version. For more details, see KA00202F/00/C4.
Order information FHX40
MadeinGermanyMaulburg
82 (3.23)6.3
106(4.71)
122(4.8)
120 (4.72)
mm (in)
max. 80 (3.15)
min. 30 (1.18)
96 (3.78)
88
(3.46)
160(6.3)
118 (4.65)
180(7.09)
1
122
(4.8)
80(3.51)
2
3
A B
4
150 (5.91)
8.5(0.33)
(0.25)
010 Approval:
A Non-hazardous area
2 ATEX II 2G Ex ia IIC T6
3 ATEX II 2D Ex ia IIIC T80°C
G IECEx Zone1 Ex ia IIC T6/T5
S FM IS Cl. I Div.1 Gr. A-D, zone 0
U CSA IS Cl. I Div.1 Gr. A-D, zone 0
N CSA General Purpose
K TIIS Ex ia IIC T6
C NEPSI Ex ia IIC T6/T5
Y Special version, TSP-Nr. to be spec.
020 Cable:
1 20 m/65 ft: for HART
5 20 m/65 ft: for PROFIBUS PA, FOUNDATION Fieldbus
9 Special version, TSP-Nr. to be spec.
030 Additional option:
A Basic version
B Mounting bracket, pipe 1"/ 2"
Prosonic M
46 Endress+Hauser
For connection of the remote display FHX40 use the cable which fits the communication version of the
respective instrument.
Technical data (cable and housing):
Materials
A0019282
Y Special version, TSP-Nr. to be spec.
995 Marking:
1 Tagging (TAG)
FHX40 - Complete product designation
Max. cable length 20 m (65 ft)
Temperature range –40 to +60 °C (–40 to +140 °F) for temperature class T6
–40 to +75 °C (–40 to +167 °F) for temperature class T5
Degree of protection IP65/67 (housing); IP68 (cable) acc. to IEC 60529
Dimensions mm (in), (HxWxD) 122x150x80 (4.8x5.9x3.2)
Position Part Material
1
Housing/Cover AlSi12, Screw: V2A
Ground terminal CuZn nickel-plated, Screw: V2A
2 Display Glass
3 Cable gland CuZn nickel-plated
4 Cable PVC
5 Mounting bracket 316 Ti (1.4571) or 316 L (1.4435) or 316 (1.4401)
6 Nut V4A
7 Plate
Screw set (M5)
316 Ti (1.4571)
Spring washer: 301 (1.4310) or V2A Screw: V4A, Nut: V4A
030 Additional option:
MadeinGerMadeinGermanmanyMaulbyMaulburgurg
4
1
2
3 6
7
53
Prosonic M
Endress+Hauser 47
Documentation
This documentation can be found on our product pages on  www.en.endress.com  download
Operating manual • BA00237F (4 to 20mA, HART)
• BA00238F (PROFIBUS PA)
• BA00239F (FOUNDATION Fieldbus)
The documentations can be found on the on the enclosed CD-ROM.
These instructions describe the installation and first commissioning of the Prosonic M. From the operating
menu, all functions are included, which are required for standard measurement tasks. Additional functions are
not contained in the manual.
Description of device
functions
BA00240F
This contains a detailed description of all the functions of the Prosonic M and is valid for all communication
variants.The documentations can be found on the on the enclosed CD-ROM.
Short instructions The following short instruction are supplied according to the communication version:
• KA01062F (4 to 20mA, HART)
• KA01063F (PROFIBUS PA)
• KA01064F (FOUNDATION Fieldbus)
These instructions describe the installation and first quick commissioning of the Prosonic M.
KA00183F
Can be found under the device housing cover.
The most important menu functions are summarised on this sheet. It is intended primarily as a memory jogger
for users who are familiar with the operating concept of Endress+Hauser time-of-flight instruments.
Prosonic M
48 Endress+Hauser
Safety Instructions ATEX The following safety instructions are supplied with ATEX-certified device versions. If the devices are used in
explosive areas, comply with all the specifications in these safety instructions.
Instrument
version
Certificate Communication Housing Safety
Instructions
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
ATEX II 1/2 G Ex ia IIC T4...T6
II 2 G Ex ia IIC T4...T6
HART (2-wire) F12 XA00174F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
ATEX II 1/2 G Ex ia IIC T4...T6
II 2 G Ex ia IIC T4...T6
HART (2-wire) T12 with overvoltage protection XA00224F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
ATEXII 1/2 G Ex ia IIC T4...T6
II 2 G Ex ia IIC T4...T6
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 XA00175F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
ATEX II 1/2 G Ex ia IIC T4...T6
II 2 G Ex ia IIC T4...T6
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 with overvoltage protection XA00225F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
ATEX II 1/2 G Ex d[ia] IIC T4...T6
II 2 G Ex d[ia] IIC T4...T6
• HART (2-wire)
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 XA00176F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU43 - ...
• FMU44 - ...
• ATEX II 3D Ex t IIC Txx °C Dc
• ATEX II 3G Ex nA IIC T6 Gc
• HART (2-wire)
• HART (4-wire, DC)
• HART (4-wire, AC)
• PROFIBUS PA
• FOUNDATION Fieldbus
• F12
• T12
• T12 with overvoltage protection
XA00179F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
• ATEX II 1/2 D, II 2 D Ex tD ... IP6X T95°C
• ATEX II 1/3 D, II 3 D Ex tD ... IP6X T95°C
• HART (2-wire)
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 XA00180F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
• ATEX II 1/2 D, II 2 D Ex tD ... IP6X T115°C
• ATEX II 1/3 D, II 3 D Ex tD ... IP6X T100°C
• HART (4-wire, DC)
• HART (4-wire, AC)
F12 XA00259
• FMU43 - ...
• ATEX II 1/2 D bzw. II 2 D
• ATEX II 1/3 D bzw. II 3 D
• HART (4-wire, DC)
• HART (4-wire, AC)
F12 XA00177F
• FMU43 - ...
• ATEX II 1/2 D bzw. II 2 D
• ATEX II 1/3 D bzw. II 3 D
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 XA00178F
Prosonic M
Endress+Hauser 49
Safety Instructions NEPSI The following safety instructions are supplied with NEPSI-certified device versions. If the devices are used in
explosive areas, comply with all the specifications in these safety instructions.
Instrument
version
Certificate Communication Housing Safety Instructions
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
Ex ia IIC T1 ... T6
NEPSI GYJ071468
HART (2-wire) F12 XA00436F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
Ex ia IIC T1 ... T6
NEPSI GYJ071468
HART (2-wire) T12 with overvoltage protection XA00442F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
Ex ia IIC T1 ... T6
NEPSI GYK071468
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 XA00437F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
Ex ia IIC T1 ... T6
NEPSI GYJ071468
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 with overvoltage protection XA00443F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
Ex d [ia] IIC T1 ... T6
NEPSI GYJ071468
• HART (2-wire)
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 XA00438F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
DIP A21/A22 TA, T*
NEPSI GYJ071468
• HART (2-wire)
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 XA00441F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
DIP A21/A22 TA, T*
NEPSI GYJ071468
• HART (4-wire, DC)
• HART (4-wire, AC)
F12 XA00444F
• FMU43 - ...
DIP A21/A22 TA, T*
NEPSI GYJ071469
• HART (4-wire, DC)
• HART (4-wire, AC)
F12 XA00439F
• FMU43 - ...
DIP A21/A22 TA, T*
NEPSI GYJ071469
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 XA00440F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
Ex nA IIC T6...T3 Gc
NEPSI GYJ12.1452
• HART
• PROFIBUS PA
• FOUNDATION Fieldbus
• F12
• T12
• F23
XA00403F
Prosonic M
50 Endress+Hauser
Control drawings Installation
drawings
The following control or installation drawings are supplied with the FM, CSA and TIIS-certified device
versions:
Instrument version Certificate Communication Housing Control or Installation
Drawing
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
FM IS HART (2-wire) F12 ZD00096F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
FM IS
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 ZD00097F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
FM IS HART (2-wire) T12 with overvoltage protection ZD00139F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
FM IS
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 with overvoltage protection ZD00140F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
FM XP
• HART (2-wire)
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 ZD00098F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
CSA IS HART (2-wire) F12 ZD00088F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
CSA IS
• PROFIBUS PA
• FOUNDATION Fieldbus
F12 ZD00099F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
CSA IS HART (2-wire) T12 with overvoltage protection ZD00101F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
CSA IS
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 with overvoltage protection ZD00102F
• FMU40 - ...
• FMU41 - ...
• FMU42 - ...
• FMU44 - ...
CSA XP
• HART (2-wire)
• PROFIBUS PA
• FOUNDATION Fieldbus
T12 ZD00100F
• FMU40 - ...
• FMU41 - ...
TIIS
Ex ia IIC T6
HART (2-wire) F12 ZD00138F
Prosonic M
Endress+Hauser 51
Instruments International
Endress+Hauser
Instruments International AG
Kaegenstrasse 2
4153 Reinach
Switzerland
Tel.+41 61 715 81 00
Fax+41 61 715 25 00
www.endress.com
info@ii.endress.com
TI00365F/00/EN/15.12
71197996
FM+SGML 9.0
7119799671197996

Mais conteúdo relacionado

Mais procurados

INSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdf
INSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdfINSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdf
INSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdfraul rivera
 
PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...
PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...
PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...jkmdm eksmd
 
Nbr5419 4-sistema eletronicos.pdf
Nbr5419 4-sistema eletronicos.pdfNbr5419 4-sistema eletronicos.pdf
Nbr5419 4-sistema eletronicos.pdfPaulo H Bueno
 
Infome Ph Paradise Towers Abr 2008
Infome Ph Paradise Towers Abr 2008Infome Ph Paradise Towers Abr 2008
Infome Ph Paradise Towers Abr 2008Tania Caplier
 
Manual de serviço electrolux top 8
Manual de serviço   electrolux top 8Manual de serviço   electrolux top 8
Manual de serviço electrolux top 8Maurilio Caetano
 
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manualPerkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manualjkmsedopl
 
Cat rolo compactador_cs533_e
Cat rolo compactador_cs533_eCat rolo compactador_cs533_e
Cat rolo compactador_cs533_eJaime Santos
 
Manual Operação e Manutenção AP300
Manual Operação e Manutenção AP300Manual Operação e Manutenção AP300
Manual Operação e Manutenção AP300Marcelo Cardozo
 
TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...
TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...
TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...Power System Operation
 
Smartline020 4-f user-manual
Smartline020 4-f user-manualSmartline020 4-f user-manual
Smartline020 4-f user-manualwoeur
 
PERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair Manual
PERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair ManualPERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair Manual
PERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair Manualfudjfjsjekkemm
 
Aea 92305-11
Aea 92305-11Aea 92305-11
Aea 92305-11JulioBuch
 
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manualPerkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manualfujsejfkskemem
 
[ T R A D U Z I D O] Codice De Talentos (814 Talentos)
[ T R A D U Z I D O]  Codice De  Talentos (814 Talentos)[ T R A D U Z I D O]  Codice De  Talentos (814 Talentos)
[ T R A D U Z I D O] Codice De Talentos (814 Talentos)Lino Naderer
 
FINAL KGB SUBMISSION
FINAL KGB SUBMISSIONFINAL KGB SUBMISSION
FINAL KGB SUBMISSIONDilawar Ali
 
The witcher 1 poradnik
The witcher 1  poradnikThe witcher 1  poradnik
The witcher 1 poradnikLudgar2
 

Mais procurados (20)

INSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdf
INSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdfINSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdf
INSTALACIONES_INDUSTRIALES_I_UNIVERSIDAD.pdf
 
PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...
PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...
PERKINS 1200 SERIES 1204F-E44TA AND 1204F-E44TTA INDUSTRIAL ENGINE(Model MU)S...
 
Pórtico 01-pórtico tqs
Pórtico 01-pórtico tqsPórtico 01-pórtico tqs
Pórtico 01-pórtico tqs
 
CATÁLOGO CB10.pdf
CATÁLOGO CB10.pdfCATÁLOGO CB10.pdf
CATÁLOGO CB10.pdf
 
Nbr5419 4-sistema eletronicos.pdf
Nbr5419 4-sistema eletronicos.pdfNbr5419 4-sistema eletronicos.pdf
Nbr5419 4-sistema eletronicos.pdf
 
Infome Ph Paradise Towers Abr 2008
Infome Ph Paradise Towers Abr 2008Infome Ph Paradise Towers Abr 2008
Infome Ph Paradise Towers Abr 2008
 
Manual de serviço electrolux top 8
Manual de serviço   electrolux top 8Manual de serviço   electrolux top 8
Manual de serviço electrolux top 8
 
Cfw 08 u line
Cfw 08 u lineCfw 08 u line
Cfw 08 u line
 
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manualPerkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manual
 
Cat rolo compactador_cs533_e
Cat rolo compactador_cs533_eCat rolo compactador_cs533_e
Cat rolo compactador_cs533_e
 
Transformer Thermal Modelling
Transformer Thermal ModellingTransformer Thermal Modelling
Transformer Thermal Modelling
 
Manual Operação e Manutenção AP300
Manual Operação e Manutenção AP300Manual Operação e Manutenção AP300
Manual Operação e Manutenção AP300
 
TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...
TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...
TECHNICAL REQUIREMENTS AND SPECIFICATIONS OF STATE-OF-THE-ART HVDC SWITCHING ...
 
Smartline020 4-f user-manual
Smartline020 4-f user-manualSmartline020 4-f user-manual
Smartline020 4-f user-manual
 
PERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair Manual
PERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair ManualPERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair Manual
PERKINS 1600 SERIES INDUSTRIAL ENGINE ( XGE ) Service Repair Manual
 
Aea 92305-11
Aea 92305-11Aea 92305-11
Aea 92305-11
 
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manualPerkins 2500 series 2506 15 industrial engine (mga ) service repair manual
Perkins 2500 series 2506 15 industrial engine (mga ) service repair manual
 
[ T R A D U Z I D O] Codice De Talentos (814 Talentos)
[ T R A D U Z I D O]  Codice De  Talentos (814 Talentos)[ T R A D U Z I D O]  Codice De  Talentos (814 Talentos)
[ T R A D U Z I D O] Codice De Talentos (814 Talentos)
 
FINAL KGB SUBMISSION
FINAL KGB SUBMISSIONFINAL KGB SUBMISSION
FINAL KGB SUBMISSION
 
The witcher 1 poradnik
The witcher 1  poradnikThe witcher 1  poradnik
The witcher 1 poradnik
 

Destaque

03 analog control_sp17
03 analog control_sp1703 analog control_sp17
03 analog control_sp17John Todora
 
Manufactura del-cemento-pdf
Manufactura del-cemento-pdfManufactura del-cemento-pdf
Manufactura del-cemento-pdfDamelis Jordan
 
Omni HR Consulting - BEE Certificate
Omni HR Consulting - BEE CertificateOmni HR Consulting - BEE Certificate
Omni HR Consulting - BEE CertificateOmni HR Consulting
 
Chapter3
Chapter3Chapter3
Chapter3suks_87
 
Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...
Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...
Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...Estudio de Comunicación
 
La traducción literaria en la construcción de la imagen de China en España Lo...
La traducción literaria en la construcción de la imagen de China en España Lo...La traducción literaria en la construcción de la imagen de China en España Lo...
La traducción literaria en la construcción de la imagen de China en España Lo...UAB - Universitat Autònoma de Barcelona
 
Kotlin compiler construction (very brief)
Kotlin compiler construction (very brief)Kotlin compiler construction (very brief)
Kotlin compiler construction (very brief)Ildar Nurgaliev
 
OnMap la solution saas de la business transformation
OnMap la solution saas de la business transformationOnMap la solution saas de la business transformation
OnMap la solution saas de la business transformationNomia
 
Poster Presentation by Hidemi Miura at ICCF20
Poster Presentation by Hidemi Miura at ICCF20Poster Presentation by Hidemi Miura at ICCF20
Poster Presentation by Hidemi Miura at ICCF20俊郎 浅学俊郎
 
Dilatacion del tiempo 01
Dilatacion del tiempo 01Dilatacion del tiempo 01
Dilatacion del tiempo 01zaritha_ballen
 
Estado del arte hipertensión pulmonar y disfuncion ventricular
Estado del arte hipertensión pulmonar y disfuncion ventricularEstado del arte hipertensión pulmonar y disfuncion ventricular
Estado del arte hipertensión pulmonar y disfuncion ventricularAgustin Omar Rosales Gutierrez
 
Five Misconceptions about Personal Data - Dataconomy Barcelona -
Five Misconceptions about Personal Data - Dataconomy Barcelona -Five Misconceptions about Personal Data - Dataconomy Barcelona -
Five Misconceptions about Personal Data - Dataconomy Barcelona -Claro Partners Inc.
 
Different kinds of enzyme on textile substrates
Different kinds of enzyme on textile substrates Different kinds of enzyme on textile substrates
Different kinds of enzyme on textile substrates Azmir Latif Beg
 
Electrofisiología y Mecanismos de Arritmogénesis
Electrofisiología y Mecanismos de ArritmogénesisElectrofisiología y Mecanismos de Arritmogénesis
Electrofisiología y Mecanismos de ArritmogénesisEdgar Hernández
 

Destaque (20)

Water samplers-Liquistation CSF48
Water samplers-Liquistation CSF48Water samplers-Liquistation CSF48
Water samplers-Liquistation CSF48
 
03 analog control_sp17
03 analog control_sp1703 analog control_sp17
03 analog control_sp17
 
41 gr
41 gr41 gr
41 gr
 
Normatividadcc
NormatividadccNormatividadcc
Normatividadcc
 
Capitulos 25 y 26
Capitulos 25 y 26Capitulos 25 y 26
Capitulos 25 y 26
 
Manufactura del-cemento-pdf
Manufactura del-cemento-pdfManufactura del-cemento-pdf
Manufactura del-cemento-pdf
 
Omni HR Consulting - BEE Certificate
Omni HR Consulting - BEE CertificateOmni HR Consulting - BEE Certificate
Omni HR Consulting - BEE Certificate
 
Chapter3
Chapter3Chapter3
Chapter3
 
Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...
Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...
Alberto Mariñas y Juana Pulido participarán un año más en el Programa Avanzad...
 
Alfombra Roja Goya 2015
Alfombra Roja Goya 2015Alfombra Roja Goya 2015
Alfombra Roja Goya 2015
 
La traducción literaria en la construcción de la imagen de China en España Lo...
La traducción literaria en la construcción de la imagen de China en España Lo...La traducción literaria en la construcción de la imagen de China en España Lo...
La traducción literaria en la construcción de la imagen de China en España Lo...
 
Kotlin compiler construction (very brief)
Kotlin compiler construction (very brief)Kotlin compiler construction (very brief)
Kotlin compiler construction (very brief)
 
OnMap la solution saas de la business transformation
OnMap la solution saas de la business transformationOnMap la solution saas de la business transformation
OnMap la solution saas de la business transformation
 
Poster Presentation by Hidemi Miura at ICCF20
Poster Presentation by Hidemi Miura at ICCF20Poster Presentation by Hidemi Miura at ICCF20
Poster Presentation by Hidemi Miura at ICCF20
 
Dilatacion del tiempo 01
Dilatacion del tiempo 01Dilatacion del tiempo 01
Dilatacion del tiempo 01
 
Estado del arte hipertensión pulmonar y disfuncion ventricular
Estado del arte hipertensión pulmonar y disfuncion ventricularEstado del arte hipertensión pulmonar y disfuncion ventricular
Estado del arte hipertensión pulmonar y disfuncion ventricular
 
Five Misconceptions about Personal Data - Dataconomy Barcelona -
Five Misconceptions about Personal Data - Dataconomy Barcelona -Five Misconceptions about Personal Data - Dataconomy Barcelona -
Five Misconceptions about Personal Data - Dataconomy Barcelona -
 
Mejor salud con una actitud positiva
Mejor salud con una actitud positivaMejor salud con una actitud positiva
Mejor salud con una actitud positiva
 
Different kinds of enzyme on textile substrates
Different kinds of enzyme on textile substrates Different kinds of enzyme on textile substrates
Different kinds of enzyme on textile substrates
 
Electrofisiología y Mecanismos de Arritmogénesis
Electrofisiología y Mecanismos de ArritmogénesisElectrofisiología y Mecanismos de Arritmogénesis
Electrofisiología y Mecanismos de Arritmogénesis
 

Semelhante a Compact Ultrasonic Level Transmitters for Non-Contact Measurement

Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...ENVIMART
 
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurementProsonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurementENVIMART
 
Prosonic s fmu90 endress+hauser datasheet-transmitter in housing
Prosonic s fmu90 endress+hauser datasheet-transmitter in housingProsonic s fmu90 endress+hauser datasheet-transmitter in housing
Prosonic s fmu90 endress+hauser datasheet-transmitter in housingENVIMART
 
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...ENVIMART
 
Levelflex fmp51 52 54-endress+hauser datasheet-guided level-radar
Levelflex fmp51 52 54-endress+hauser datasheet-guided level-radarLevelflex fmp51 52 54-endress+hauser datasheet-guided level-radar
Levelflex fmp51 52 54-endress+hauser datasheet-guided level-radarENVIMART
 
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeterProline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeterENVIMART
 
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeterProsonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeterENVIMART
 
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeterProline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeterENVIMART
 
Waterpilot fmx21 endress+hauser datasheet-level transmitter
Waterpilot fmx21 endress+hauser datasheet-level transmitterWaterpilot fmx21 endress+hauser datasheet-level transmitter
Waterpilot fmx21 endress+hauser datasheet-level transmitterENVIMART
 
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeterProline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeterENVIMART
 
Liquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheetLiquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheetENVIMART
 
Proline promag w 800 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 800 endress+hauser datasheet-electromagnetic flowmeterProline promag w 800 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 800 endress+hauser datasheet-electromagnetic flowmeterENVIMART
 
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeterProline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeterENVIMART
 

Semelhante a Compact Ultrasonic Level Transmitters for Non-Contact Measurement (20)

Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
 
Guided Level Radar-Levelflex M FMP40
Guided Level Radar-Levelflex M FMP40Guided Level Radar-Levelflex M FMP40
Guided Level Radar-Levelflex M FMP40
 
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
 
Ultrasonic Level Measurement-Prosonic T FMU30
Ultrasonic Level Measurement-Prosonic T FMU30Ultrasonic Level Measurement-Prosonic T FMU30
Ultrasonic Level Measurement-Prosonic T FMU30
 
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurementProsonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
 
Fmu90 ti
Fmu90 tiFmu90 ti
Fmu90 ti
 
Prosonic s fmu90 endress+hauser datasheet-transmitter in housing
Prosonic s fmu90 endress+hauser datasheet-transmitter in housingProsonic s fmu90 endress+hauser datasheet-transmitter in housing
Prosonic s fmu90 endress+hauser datasheet-transmitter in housing
 
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
 
Levelflex fmp51 52 54-endress+hauser datasheet-guided level-radar
Levelflex fmp51 52 54-endress+hauser datasheet-guided level-radarLevelflex fmp51 52 54-endress+hauser datasheet-guided level-radar
Levelflex fmp51 52 54-endress+hauser datasheet-guided level-radar
 
Flowmeter Promag W 400-Electromagnetic-Water and Waste Water
Flowmeter Promag W 400-Electromagnetic-Water and Waste WaterFlowmeter Promag W 400-Electromagnetic-Water and Waste Water
Flowmeter Promag W 400-Electromagnetic-Water and Waste Water
 
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeterProline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
 
Ultrasonic flowmeter-Drinking water, wastewater and process water.
Ultrasonic flowmeter-Drinking water, wastewater and process water.Ultrasonic flowmeter-Drinking water, wastewater and process water.
Ultrasonic flowmeter-Drinking water, wastewater and process water.
 
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeterProsonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
 
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeterProline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
 
Waterpilot fmx21 endress+hauser datasheet-level transmitter
Waterpilot fmx21 endress+hauser datasheet-level transmitterWaterpilot fmx21 endress+hauser datasheet-level transmitter
Waterpilot fmx21 endress+hauser datasheet-level transmitter
 
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeterProline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
 
Liquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheetLiquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheet
 
Proline promag w 800 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 800 endress+hauser datasheet-electromagnetic flowmeterProline promag w 800 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 800 endress+hauser datasheet-electromagnetic flowmeter
 
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
 
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeterProline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
 

Mais de Edress Hauser: Flow Meter, Level, Pressure, Temperature

Mais de Edress Hauser: Flow Meter, Level, Pressure, Temperature (20)

Liquiphant M Density and Density Computer FML621
Liquiphant M Density and Density Computer FML621Liquiphant M Density and Density Computer FML621
Liquiphant M Density and Density Computer FML621
 
Microwave barrier- Soliwave FQR56/FDR56
Microwave barrier- Soliwave FQR56/FDR56Microwave barrier- Soliwave FQR56/FDR56
Microwave barrier- Soliwave FQR56/FDR56
 
Microwave barrier-Soliwave M FQR50 / FDR50
Microwave barrier-Soliwave M FQR50 / FDR50Microwave barrier-Soliwave M FQR50 / FDR50
Microwave barrier-Soliwave M FQR50 / FDR50
 
Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31
 
Level limit switch-Soliswitch FTE30
Level limit switch-Soliswitch FTE30Level limit switch-Soliswitch FTE30
Level limit switch-Soliswitch FTE30
 
Flow indicator for bulk solids-Solimotion FTR20
Flow indicator for bulk solids-Solimotion FTR20Flow indicator for bulk solids-Solimotion FTR20
Flow indicator for bulk solids-Solimotion FTR20
 
Level measurement with Prothermo NMT532
Level measurement with Prothermo NMT532 Level measurement with Prothermo NMT532
Level measurement with Prothermo NMT532
 
High accuracy liquid level measurement-Proservo NMS5
High accuracy liquid level measurement-Proservo NMS5High accuracy liquid level measurement-Proservo NMS5
High accuracy liquid level measurement-Proservo NMS5
 
Conductive Limit Detection-Rod Probe 11263
Conductive Limit Detection-Rod Probe 11263Conductive Limit Detection-Rod Probe 11263
Conductive Limit Detection-Rod Probe 11263
 
FTW360 compact pump protector
FTW360 compact pump protectorFTW360 compact pump protector
FTW360 compact pump protector
 
Conductive-Point level switch for multiple point
Conductive-Point level switch for multiple pointConductive-Point level switch for multiple point
Conductive-Point level switch for multiple point
 
Level limit switch compact design-Liquiphant T FTL20H
Level limit switch compact design-Liquiphant T FTL20HLevel limit switch compact design-Liquiphant T FTL20H
Level limit switch compact design-Liquiphant T FTL20H
 
Vibronic-Point level switch for all kinds of liquids
Vibronic-Point level switch for all kinds of liquidsVibronic-Point level switch for all kinds of liquids
Vibronic-Point level switch for all kinds of liquids
 
Vibronic-Point level switch-Liquiphant M FTL51C
Vibronic-Point level switch-Liquiphant M FTL51CVibronic-Point level switch-Liquiphant M FTL51C
Vibronic-Point level switch-Liquiphant M FTL51C
 
Level limit switch for liquids-Liquiphant T FTL20
Level limit switch for liquids-Liquiphant T FTL20Level limit switch for liquids-Liquiphant T FTL20
Level limit switch for liquids-Liquiphant T FTL20
 
Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20
 
Differential pressure measurement-Level transmiter
Differential pressure measurement-Level transmiterDifferential pressure measurement-Level transmiter
Differential pressure measurement-Level transmiter
 
Capacitance level measurement-Liquicap M FMI51, FMI52
Capacitance level measurement-Liquicap M FMI51, FMI52Capacitance level measurement-Liquicap M FMI51, FMI52
Capacitance level measurement-Liquicap M FMI51, FMI52
 
Electromechanical Level Measuring System-Silopilot M FMM50
Electromechanical Level Measuring System-Silopilot M FMM50Electromechanical Level Measuring System-Silopilot M FMM50
Electromechanical Level Measuring System-Silopilot M FMM50
 
Electromechanical Level System-Silopilot T FMM20
Electromechanical Level System-Silopilot T FMM20Electromechanical Level System-Silopilot T FMM20
Electromechanical Level System-Silopilot T FMM20
 

Último

Take control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteTake control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteDianaGray10
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupFlorian Wilhelm
 
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptxPasskey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptxLoriGlavin3
 
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdfHyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdfPrecisely
 
Generative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information DevelopersGenerative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information DevelopersRaghuram Pandurangan
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Mark Simos
 
DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenHervé Boutemy
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLScyllaDB
 
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESSALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESmohitsingh558521
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningLars Bell
 
What is DBT - The Ultimate Data Build Tool.pdf
What is DBT - The Ultimate Data Build Tool.pdfWhat is DBT - The Ultimate Data Build Tool.pdf
What is DBT - The Ultimate Data Build Tool.pdfMounikaPolabathina
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubKalema Edgar
 
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024BookNet Canada
 
Advanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionAdvanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionDilum Bandara
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfLoriGlavin3
 
The Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsThe Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsPixlogix Infotech
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxLoriGlavin3
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 

Último (20)

Take control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteTake control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test Suite
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project Setup
 
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptxPasskey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptx
 
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdfHyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
Hyperautomation and AI/ML: A Strategy for Digital Transformation Success.pdf
 
Generative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information DevelopersGenerative AI for Technical Writer or Information Developers
Generative AI for Technical Writer or Information Developers
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
 
DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache Maven
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQL
 
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESSALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine Tuning
 
What is DBT - The Ultimate Data Build Tool.pdf
What is DBT - The Ultimate Data Build Tool.pdfWhat is DBT - The Ultimate Data Build Tool.pdf
What is DBT - The Ultimate Data Build Tool.pdf
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding Club
 
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
 
Advanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionAdvanced Computer Architecture – An Introduction
Advanced Computer Architecture – An Introduction
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdf
 
The Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsThe Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and Cons
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 

Compact Ultrasonic Level Transmitters for Non-Contact Measurement

  • 1. TI00365F/00/EN/15.12 71197996 Technical Information Prosonic M FMU40/41/42/43/44 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials Application • Continuous, non-contact level measurement in fluids, pastes, sullages and coarse bulk materials • Flow measurement in open channels and measuring weirs • System integration via: – HART (standard), 4 to 20mA – PROFIBUS PA – FOUNDATION Fieldbus • Maximum measuring range: – FMU40: 5 m (16 ft) in fluids, 2 m (6.6 ft) in bulk materials – FMU41: 8 m (26 ft) in fluids, 3,5 m (11 ft) in bulk materials – FMU42: 10 m (33 ft) in fluids, 5 m (16 ft) in bulk materials – FMU43: 15 m (49 ft) in fluids, 7 m (23 ft) in bulk materials – FMU44: 20 m (66 ft) in fluids, 10 m (33 ft) in bulk materials Features and benefits • Quick and simple commissioning via menu-guided on- site operation with four-line plain text display; 7 languages selectable • Envelope curves on the on-site display for simple diagnosis • Easy remote operation, diagnosis and measuring point documentation with the free operating program FieldCare supplied. • Suitable for explosion hazardous areas (Gas-Ex, Dust-Ex) • Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate • Non-contact measurement method minimizes service requirements • Optional remote display and operation (up to 20 m (66 ft) from transmitter) • Installation possible from thread G 1½“ or 1½“ NPT upwards • Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
  • 2. Prosonic M 2 Endress+Hauser Table of contents Function and system design. . . . . . . . . . . . . . . . . . . . . 3 Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Equipment architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Load HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Output damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Linearization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Terminal compartment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Fieldbus plug connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Current consumption (2 wire instruments) . . . . . . . . . . . . . . . . 14 HART ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Max. noise HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Performance characteristics. . . . . . . . . . . . . . . . . . . . 15 Reaction time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Reference operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Measured value resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Pulse frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Maximum measuring error . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Typical measuring error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Influence of the vapor pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Installation variants FMU40, FMU41 . . . . . . . . . . . . . . . . . . . . . 16 Installation variants FMU42, FMU44 . . . . . . . . . . . . . . . . . . . . . 16 Installation variants FMU43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Installation conditions for level measurements . . . . . . . . . . . . . . 17 Installation in narrow shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installation conditions for flow measurements . . . . . . . . . . . . . . . 18 Blocking distance, nozzle installation . . . . . . . . . . . . . . . . . . . . . 20 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Resistance to alternating temperature cycles . . . . . . . . . . . . . . . . 21 Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ingress protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . 21 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Process temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Process pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 22 Design; dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Housing design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Process connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Material (not in contact with process) . . . . . . . . . . . . . . . . . . . . . 26 Material (in contact with process) . . . . . . . . . . . . . . . . . . . . . . . . 27 Operability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Display and operating elements . . . . . . . . . . . . . . . . . . . . . . . . . 28 On-site operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Certificates and Approvals. . . . . . . . . . . . . . . . . . . . . 31 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 External standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . 31 Ordering information. . . . . . . . . . . . . . . . . . . . . . . . . 32 Product structure FMU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Product structure FMU41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Product structure FMU42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Product structure FMU43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Product structure FMU44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 5-point linearity protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Weather protection cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Installation bracket for FMU40, FMU41 . . . . . . . . . . . . . . . . . . . 41 Screw in flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Cantilever with mounting frame or wall bracket . . . . . . . . . . . . . 43 Commubox FXA195 HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Commubox FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 ToF Adapter FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Remote display FHX40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Operating manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Description of device functions . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Short instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Safety Instructions ATEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Safety Instructions NEPSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Control drawings, Installation drawings . . . . . . . . . . . . . . . . . . . 50
  • 3. Prosonic M Endress+Hauser 3 Function and system design Measuring principle A0019264 BD Blocking distance D Distance from sensor membrane - product surface E Empty distance F Span (full distance) L Level Time-of-flight method The sensor of the Prosonic M transmits ultrasonic pulses in the direction of the product surface. There, they are reflected back and received by the sensor. The Prosonic M measures the time t between pulse transmission and reception. The instrument uses the time t (and the velocity of sound c) to calculate the distance D between the sensor membrane and the product surface: D = c  t/2 As the device knows the empty distance E from a user entry, it can calculate the level as follows: L = E - D An integrated temperature sensor (NTC) compensates for changes in the velocity of sound caused by temperature changes. Interference echo suppression The interference echo suppression feature on the Prosonic M ensures that interference echos (e.g. from edges, welded joints and installations) are not interpreted as a level echo. Calibration Enter the empty distance E and the span F to calibrate the device. Blocking distance Span F may not extend into the blocking distance BD. Level echos within the blocking distance cannot be evaluated due to the transient characteristics of the sensor. 20 mA 100% 4 mA 0% D L F E BD Sensor BD Max. range fluids Max. range bulk materials FMU40 0.25 (0.8) 5 (16) 2 (6.6) FMU41 0.35 (1.1) 8 (26) 3.5 (11) FMU42 0.4 (1.3) 10 (33) 5 (16) FMU43 0.6 (2.0) 15 (49) 7 (23) FMU44 0.5 (1.6) 20 (66) 10 (33) m (ft)
  • 4. Prosonic M 4 Endress+Hauser Equipment architecture 4…20 mA output with HART protocol The complete measuring system consists of: A0019266 1 PLC (programmable logic controller) 2 Commubox FXA191 (RS232) or FXA195 (USB) 3 Computer with operating tool (e.g. FieldCare) 4 Commubox FXA291 with ToF Adapter FXA291 5 Power supply (for 4-wire) 6 Prosonic with display and operating modul 7 Field Xpert SFX100 8 VIATOR Bluetooth modem with connection cable 9 Connection for Commubox FXA191, FXA195 or Field Xpert SFX100 10 Transmitter supply unit RMA422 or RN221N (communication resistor included) If the HART communication resistor is not built into the supply unit, it is necessary to insert a communication resistor of 250  into the 2-wire line. On-site operation • With display and operating module, • With a Personal Computer, FXA291 with ToF Adapter FXA291 (USB) and the operating software "FieldCare". FieldCare is a graphical operating software for instruments (radar, ultrasonic, guided microimpulse). It assists with commissioning, securing data, signal analysis and documentation of the measuring point. Remote operation • With Field Xpert SFX100 • With a Personal Computer, Commubox FXA195 and the operating software "FieldCare" ENDRESS + HAUSER E+– % ENDRESS + HAUSER RMA 422 2 4 6789 10 5 1 3
  • 5. Prosonic M Endress+Hauser 5 System integration using PROFIBUS PA A maximum of 32 transmitters (8 if mounted in an explosion hazardous location Ex ia IIC according to FISCO- model) can be connected to the bus.The segment coupler provides the operating voltage to the bus. Both on- site as well as remote operation are possible. For further information on the cable specifications, see Operating Instructions BA00034S/04/ENGuidelines for planning and commissioning PROFIBUS DP/PA", PNO Guideline 2.092 "PROFIBUS PA User and Installation Guideline" and IEC61158-2 (MBP). A0019308 1 Computer with Profiboard/Proficard and operating tool (FieldCare) 2 PROFIBUS DP 3 PLC (programmable logic controller) 4 More functions (valves etc.) 5 Computer with operating tool (FieldCare) 6 Commubox FXA291 with ToF Adapter FXA291 7 Levelflex M 8 Prosonic M 9 Micropilot M with display and operating modul 10 PROFIBUS PA 11 Segment coupler ENDRESS + HAUSERENDRESS + HAUSER T 1 3 211 10 4 56 789 ENDRESS + HAUSER E+– %
  • 6. Prosonic M 6 Endress+Hauser System integration using FOUNDATION Fieldbus A maximum of 32 transmitters (standard or Ex d) can be connected to the bus. For protection class Ex ia: the maximum number of transmitters depends on the established rules and standards for intrinsically safe circuits (EN 60070-14) and proof of instrinsic safety. Both on-site and remote operation are possible. A0019309 1 SPS, PLC, API 2 Personal computer, e.g. with NI-FBUS configurator 3 VIATOR Bluetooth modem with connection cable 4 Field Xpert SFX100 5 More functions (valves etc.) 6 FieldCare 7 Commubox FXA291 with ToF Adapter FXA291 8 Levelflex M 9 Prosonic M 10 Micropilot M 11 Power conditioner 12 Power supply 13 FF link 14 FOUNDATION Fieldbus 15 Ethernet T T 15 13 14 1 6 5 7 11 12 3 4 8910 2
  • 7. Prosonic M Endress+Hauser 7 System integration using Endress+Hauser Rackbus You can interconnect a maximum of 64 2-wire devices with HART protocol to a Rackbus. Use an FXN672 interface module for each device. You can integrate this bus into a higher-level bus by using gateway. A0019307 1 Interface FXN672 2 Personal computer with communication software 3 Bus 4 PLC 5 Gateway to MODBUS, FIP, PROFIBUS, INTERBUS etc. 6 4-20 mA HART 7 FieldCare 8 Commubox FXA291 with ToF Adapter FXA291 9 Levelflex M 10 Prosonic M 11 Micropilot M with display and operating modul Note! The FXN672 can be used with all 2-wire devices of the Prosonic M family. FXN 671 mA1 + FXN 671 mA1 + FXN 671 mA1 + ENDRESS + HAUSER E+– % 3 9 2 4 1 7 1011 8 5 6
  • 8. Prosonic M 8 Endress+Hauser System integration via Fieldgate Vendor Managed Inventory By using Fieldgates to interrogate tank or silo levels remotely, suppliers of raw materials can provide their regular customers with information about the current supplies at any time and, for example, account for them in their own production planning. For their part, the Fieldgates monitor the configured level limits and, if required, automatically activate the next supply. The spectrum of options here ranges from a simple purchasing requisition via e-mail through to fully automatic order administration by coupling XML data into the planning systems on both sides. Remote maintenance of measuring equipment Fieldgates not only transfer the current measured values, they also alert the responsible standby personnel, if required, via e-mail or SMS. In the event of an alarm or also when performing routine checks, service technicians can diagnose and configure connected HART devices remotely. All that is required for this is the corresponding HART operating software (e.g. FieldCare) for the connected device. Fieldgate passes on the information transparently, so that all options for the respective operating software are available remotely. Some on-site service operations can be avoided by using remote diagnosis and remote configuration and all others can at least be better planned and prepared. A0019306 The complete measuring system consists of devices and: 1 Fieldgate FXA520 2 Multidrop Connector FXN520 Note! The number of instruments which can be connected in mutidrop mode can be calculated by the "FieldNetCalc" program. A description of this program can be found in Technical Information TI00400F/00/EN (Multidrop Conncector FXN520). The program is available form your Endress+Hauser sales organisation or in the internet at: "www.endress.com  select your country download search: Fieldnetcalc - ENDRESS+HAUSER RN 221N ENDRESS+HAUSER RN 221N . 20...45 VDC FXN520FXN520 1 1 2
  • 9. Prosonic M Endress+Hauser 9 Input Measured variable The distance D between the sensor membrane and the product surface is measured. Using the linearization function, the device uses D to calculate: • level L in any units • volume V in any units • Flow Q across measuring weirs or open channels in any units Measuring range The measuring range is limited by the range of a sensor. The sensor range is, in turn, dependent on the operating conditions. To estimate the actual range, proceed as follows (see also the calculation example in the diagram): 1. Determine which of the influences shown in the following table are appropriate for your process. 2. Add the corresponding attenuation values. 3. From the total attenuation, use the diagram to calculate the range. Fluid surface Attenuation Calm 0 dB Waves 5 to 10 dB Strong turbulence (e.g. stirrers) 10 to 20 dB Foaming Please contact your Endress+Hauser sales representative. Bulk material surface Attenuation Hard, rough (e.g. rubble) 40 dB Soft (e.g. peat, dust-covered clinker) 40 to 60 dB Dust Attenuation No dust formation 0 dB Little dust formation 5 dB Heavy dust formation 5 to 20 dB Filling curtain in detection range Attenuation None 0 dB Small quantities 5 to 10 dB Large quantities 10 to 40 dB Temperature difference between sensor and product surface Attenuation to 20 °C (68 °F) 0 dB to 40 °C (104 °F) 5 to 10 dB to 80 °C (176 °F) 10 to 20 dB
  • 10. Prosonic M 10 Endress+Hauser A0019268 A Attenuation (dB) R Range (m) Example (for FMU43) For typical solid applications, a certain amount of dust coverage is normally present. Therefore, the following range results from the table and the diagram: These measuring conditions have been taken into account during the calculation of the maximum measuring range in solid applications. Operating frequency 10 20 30 40 50 60 70 80 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 FMU44 A [dB] R [m] 0 FMU43 FMU42 FMU41 FMU40 • Dust-covered rubble approx. 50 dB • No dust formation 0 dB • No filling curtain in detection range 0 dB • Temperature diff. < 20°C 0 dB approx. 50 dB  range approx. 7 m (23 ft) Sensor Operating frequency FMU40 approx. 70 kHz FMU41 approx. 50 kHz FMU42 approx. 42 kHz FMU43 approx. 35 kHz FMU44 approx. 30 kHz
  • 11. Prosonic M Endress+Hauser 11 Output Output signal According to the instrument version ordered: • 4…20 mA with HART protocol • PROFIBUS PA • FOUNDATION Fieldbus Signal on alarm Error information can be accessed via the following interfaces: • On-site display (error symbol, error code and plain text description) • Current output, signal on error can be selected (e.g. according to NAMUR recommendation NE43) • Digital interface Load HART Minimum load for HART communication: 250  Output damping Freely selectable, 0 to 255 s Linearization The linearization function of the Prosonic M allows conversion of the measured value into any unit of length or volume. In open channels or measuring weirs, also a flow linearization is possible (calculation of the flow from the measured level). The linearization table for calculating the volume in an horizontal cylindrical tank is preprogrammed. You can also enter any number of other tables containing up to 32 value pairs either manually or semi-automatically (by filling the vessel under controlled conditions). The supplied FieldCare operating program can automatically calculate the table for any tank, weir or flume and upload it into the device. Flow curves for open channels can be calculated and entered into the instrument by the FieldCare as well ( ä 29, "Operation with FieldCare").
  • 12. Prosonic M 12 Endress+Hauser Power supply Terminal compartment In the F12 housing, the terminals are located underneath the housing cover. In the T12 housing, they are under the cover of the separate terminal compartment. A0019271 A F12 housing B T12 housing 1 Sealed terminal compartment Terminal assignment A0019268 A Loop-powered version 3 Plant ground B 4-wire version (active) 4 4-20 mA HART 1 Power 5 Display unit, recorder, PCS 2 Test clamp for testing of the signal current • Connect the connecting line to the screw terminals (line cross-sections of 0.5 to 2.5mm (20 to 14 AWG)) in the terminal compartment. • Use 2-wire twisted pair cable with screen for the connection. • Protective circuitry against reverse polarity, RFI and over-voltage peaks is built into the device (see also Technical Information TI00241F/00/EN "EMC Test Procedures")  ä 21, "Electromagnetic compatibility (EMC)". • A standard installation cable is sufficient if only the analogue signal is used. Use a screened cable when working with a superimposed communication signal (HART). 1 A B 2 1 4 A B 3 3 1 2 3 4 5 6 1 2 L- L+ I+ I- I+ I- L1/L+ N/L- 4 1 5
  • 13. Prosonic M Endress+Hauser 13 The digital communication signal is transmitted to the bus via a 2-wire connection. The bus also provides the auxiliary energy. Use 2-wire twisted pair cable with screen. Refer to the following operating manuals for information on cable types, and how to set up and ground the network: • BA00034S "PROFIBUS DP/PA: "Guidelines for planning and commissioning PROFIBUS DP/PA", PNO Guideline 2.092 "PROFIBUS PA User and Installation Guideline" and IEC61158-2 (MBP). • BA00013S "FOUNDATION Fieldbus Overview", FONDATION Fieldbus Guideline and IEC61158-2 (MBP). Fieldbus plug connectors For the versions with fieldbus plug connector (M12 or 7/8"), the signal line can be connected without opening the housing. Pin assignment of the M12 plug connector (PROFIBUS PA plug) Pin assignment of the 7/8" plug connector (FOUNDATION Fieldbus plug) Supply voltage HART, 2-wire The following values are the voltages across the terminals directly at the instrument: PROFIBUS PA A0019276 1 T-Box 2 PROFIBUS PA 3 Plant ground FOUNDATION Fieldbus A0019275 3 41 2 +– 3 1 2 3 41 2 +– 3 A0011175 Pin Meaning 1 Signal + 2 not connected 3 Signal - 4 Ground A0011176 Pin Meaning 1 Signal - 2 Signal + 3 Shield 4 Not connected 21 34 + – nc 2 1 4 3
  • 14. Prosonic M 14 Endress+Hauser HART, 4-wire, active Terminals Cable cross-section: 0.5 to 2.5 mm2 (20 to 14 AWG) Cable entry • Cable gland: M20x1.5 (recommended cable diameter 6 to 10 mm (0.24 to 0.39 in)) • Cable entry G ½" or NPT ½" • PROFIBUS PA M12 plug • FOUNDATION Fieldbus 7/8" plug Power consumption Current consumption (2 wire instruments) HART ripple 47 to 125 Hz: Vpp = 200 mV (measured at 500 ) Max. noise HART 500 Hz to 10 kHz: Vrms = 2.2 mV (measured at 500 ) Galvanic isolation With 4-wire devices, the evaluation electronics and mains voltage are galvanically isolated from each other. Version Current consumption Terminal voltage minimum Terminal voltage maximum 2-wire HART Standard 4 mA 14 V 36 V 20 mA 8 V 36 V Ex ia 4 mA 14 V 30 V 20 mA 8 V 30 V Ex d 4 mA 14 V 30 V 20 mA 11 V 30 V Fixed current, adjustable, e.g. for solar power operation (measured value via HART) Standard 11 mA 10 V 36 V Ex ia 11 mA 10 V 30 V Fixed current for HART multidrop mode Standard 4 mA1) 1) Start-up current 11 mA 14 V 36 V Ex ia 4 mA1 14 V 30 V Version Voltage Max. load DC 10.5 to 32 V 600  AC 50/60 Hz 90 to 253 V 600  Version Power consumption 2-wire 51 mW to 800 mW 4-wire AC max. 4VA 4-wire DC; FMU40/41 330 mW to 830 mW 4-wire DC; FMU42/43 600 mW to 1 W Communication Current consumption HART 3.6 to 22 mA PROFIBUS PA max. 13 mA FOUNDATION Fieldbus max. 15 mA
  • 15. Prosonic M Endress+Hauser 15 Performance characteristics Reaction time The reaction time depends on the parameter settings. The minimum values are: • 2-wire devices (FMU40/41/42): min. 2 s • 2-wire diveces (FMU43 - PROFIBUS PA or FOUNDATION Fieldbus): min. 2 s • 2-wire devices (FMU44): min. 3 s • 4-wire devices (FMU40/41/42/43/44): 0.5 s Reference operating conditions • Temperature = +20 °C (+68 °F) • Pressure = 1013 mbar abs. (15 psi abs.) • Humidity = 50 % • Ideal reflective surface (e.g. calm, smooth fluid surface) • No interference reflections within signal beam • Set application parameters: – Tank shape = dome ceiling – Medium property = liquid – Process conditions = standard liquid Measured value resolution Pulse frequency • 2-wire devices (FMU40/41/42): max. 0.5Hz • 2-wire devices (FMU43 - PROFIBUS PA or FOUNDATION Fieldbus): max. 0.5 Hz • 2-wire devices (FMU44): max. 0.3 Hz • 4-wire devices (FMU40/41/42/43/44): max. 2Hz The exact values are dependent on the type of device and the parameter settings. Maximum measuring error1) 2) ±0.2 % of the maximum span of the sensor Typical measuring error Include linearity, repeatability and hysteresis Better than: Influence of the vapor pressure The vapor pressure at 20 °C (68 °F) gives a hint on the accuracy of the ultrasonic level measurement. If the vapor pressure at 20 °C (68 °F) is below 50 mbar (1 psi), ultrasonic level measurement is possible with a very high accuracy. This is valid for water, aqueous solutions, water-solid-solutions, dilute acids (hydrochloric acid, sulfuric acid, ...), dilute bases (caustic soda, ...), oils, greases, slurries, pastes, ... High vapor pressures or outgassing media (ethanol, acetone, ammonia, ...) can influence the accuracy. If conditions like these are present, please contact your Endress+Hauser sales representative. Sensor Measured value resolution FMU40 1 mm (0.04 in) FMU41 1 mm (0.04 in) FMU42 2 mm (0.08 in) FMU43 2 mm (0.08 in) FMU44 2 mm (0.08 in) 1) according to EN 61298-2 2) with reference operating conditions Sensor Measuring error FMU40 ±2 mm (0.08 in) or 0.2 % of measuring distance* FMU41 ±2 mm (0.08 in) or 0.2 % of measuring distance* FMU42 ±4 mm (0.16 in) or 0.2 % of measuring distance* FMU43 ±4 mm (0.16 in) or 0.2 % of measuring distance* FMU44 ±4 mm (0.16 in) or 0.2 % of measuring distance* * whichever is greater
  • 16. Prosonic M 16 Endress+Hauser Installation Installation variants FMU40, FMU41 A0019052 A Installation with counter nut 1 Counter nut (PC) supplied for G 1½" and G 2" instruments B Installation with sleeve 1 Sealing (EPDM) supplied C Installation with installation bracket D Installation with screw in flange 1 Sealing (EPDM) supplied 2 Nozzle 3 Sensor 4 Screw in flange For installation bracket or adapter flange  ä 41, "Accessories". Installation variants FMU42, FMU44 A0019280 A Installation with universal flange (Ex-hazardous, e.g. Zone 20) B Installation with mounting bracket (Non-Ex-hazardous, Zone 20) ENDRESS+HAUSER Prosonic M ENDRESS+HAUSER Prosonic M A B C D 1 1 1 23 4 A B - .
  • 17. Prosonic M Endress+Hauser 17 Installation variants FMU43 A0019053 A Installation with universal slip-on flange (option), (Ex-hazardous, e.g. Zone 20) 1 Sensor 2 Nozzle 3 Slip-on flange B Installation with mounting bracket (Non-Ex-hazardous, Zone 20) Installation conditions for level measurements A0019278 • Do not install the sensor in the middle of the tank (3). We recommend leaving a distance between the sensor and the tank wall (1) measuring 1/6 of the tank diameter. • Use a protective cover, in order to protect the device from direct sun or rain (2)  ä 41, "Weather protection cover". • Avoid measurements through the filling curtain (4). • Make sure that equipment (5) such as limit switches, temperature sensors, etc. are not located within the emitting angle . In particular, symmetrical equipment (6) such as heating coils, baffles etc. can influence measurement. • Align the sensor so that it is vertical to the product surface (7). • Never install two ultrasonic measuring devices in a tank, as the two signals may affect each other. • To estimate the detection range, use the 3 dB emitting angle . ENDRESS+HAUSER Prosonic M 13 2 A B - . 2 3 4 1/6D D 1 5 6 L r 7 Sensor  Lmax rmax FMU40 11° 5 (16) 0.48 (1.6) FMU41 11° 8 (26) 0.77 (2.5) FMU42 9° 10 (33) 0.79 (2.6) FMU43 6° 15 (49) 0.79 (2.6) FMU44 11 ° 20 (66) 1.93 (6.3) m (ft)
  • 18. Prosonic M 18 Endress+Hauser Installation in narrow shafts Installation conditions for flow measurements • Install the Prosonic M at the inflow side, as close above the maximum water level Hmax as possible (take into account the blocking distance BD). • Position the Prosonic M in the middle of the channel or weir. • Align the sensor membrane parallel to the water surface. • Keep to the installation distance of the channel or weir. • You can enter the "Flow to Level" linearization curve ("Q/h curve") using FieldCare or manually via the on- site display. Example: Khafagi-Venturi flume A0019606 A Khafagi-Venturi flume B Inflow C Outflow BD Blocking distance E Empty calibration F Full calibration V Direction of flow In narrow shafts with strong interference echoes, we recommend using an ultrasound guide pipe (e.g. PE or PVC wastewater pipe) with a minimum diameter of 100 mm (3.94 in). Make sure that the pipe is not soiled by accumulated dirt. If necessary, clean the pipe at regular intervals. A0019310 1 Venting hole 1 1 x b0 b0 BD A E B C VHmax =F
  • 19. Prosonic M Endress+Hauser 19 Example: Triangular weir A0019312 BD Blocking distance E Empty calibration F Full calibration (= F) min. 3 H H min. 2 H a min. 2 H BD E max. max. max. max.
  • 20. Prosonic M 20 Endress+Hauser Blocking distance, nozzle installation Install the Prosonic M at a height so that the blocking distance BD is not undershot, even at maximum fill level. Use a pipe nozzle if you cannot maintain the blocking distance in any other way. The interior of the nozzle must be smooth and may not contain any edges or welded joints. In particular, there should be no burr on the inside of the tank side nozzle end. Note the specified limits for nozzle diameter and length. To minimise disturbing factors, we recommend an angled socket edge (ideally 45°). A0019311 A FMU40, FMU41 B FMU42, FMU44 C FMU43 BD Blocking distance F Full calibration (span) SD Safety distance D Nozzle diameter E Empty calibration L Nozzle length Caution! If the blocking distance is undershot, it may cause device malfunction. Note! In order to notice if the level approaches the blocking distance, you can specify a safety distance (SD). If the level is within this safety distance, the Prosonic M outputs a warning or alarm message. F E BD SD L D L D L D A B C Maximum nozzle length [mm (in)] Nozzle diameter FMU40 FMU41 FMU42 FMU43 FMU44 DN50/2" 80 (3.15)     DN80/3" 240 (9.45) 240 (9.45) 250 (9.84)   DN100/4" 300 (11.8) 300 (11.8) 300 (11.8) 300 (11.8)  DN150/6" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7) DN200/8" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7) DN250/10" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7) DN300/12" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7) Sensor characteristics Emitting angle  11° 11° 9° 6° 11° Blocking distance [m (ft)] 0.25 (0.8) 0.35 (1.1) 0.4 (1.3) 0.6 (2.0) 0.5 (1.6) Max. range [m (ft)] in liquids 5 (16.0) 8 (26.0) 10 (33.0) 15 (49.0) 20 (66.0) Max. range [m (ft)] in solids 2 (6.6) 3.5 (11.0) 5 (16.0) 7 (23.0) 10 (33.0)
  • 21. Prosonic M Endress+Hauser 21 Environment Ambient temperature –40 °C to +80 °C (–40 °F to +176 °F) The functionality of the LC display becomes restricted at Tu<–20 °C (Tu<–4 °F) and Tu>+60 °C (Tu>140 °F). If the device is operated outdoors in strong sunlight, you should use a protective cover ( ä 41). Storage temperature –40 °C to +80 °C (–40 °F to +176 °F) Resistance to alternating temperature cycles To DIN EN 60068-2-14; Nb test: +80°C/–40°C (+176 °F/–40 °F), 1K/min, 100cycles Climate class DIN EN 60068-2-38 (Test Z/AD) DIN/IEC 68 T2-30Db Ingress protection • With closed housing, tested according to – IP68, NEMA 6P (24h at 1.83 m (6 ft) under water surface) – IP66, NEMA 4x • With open housing: IP20, NEMA 1 (also ingress protection of the display) Caution! Degree of protection IP68 NEMA 6P applies for M12 PROFIBUS-PA plugs and for 7/8" FF plug only when the cable is plugged in. Vibration resistance DIN EN 60068-2-64 / IEC 68-2-64: 20…2000 Hz, 1 (m/s )2 /Hz; 3 x 100 min Electromagnetic compatibility (EMC) • Electromagnetic compatibility according to all relevant requirements of the EN 61326- series and NAMUR recommendation EMC (NE21). For details see declaration of conformity. • A standard installation cable is sufficient if only the analogue signal is used. Use a screened cable when working with a superimposed communication signal (HART). Process Process temperature –40°C to +80°C (–40 °F...+176 °F) A temperature sensor is integrated in the sensor for correction of the temperature-dependent time-of-flight. Process pressure • FMU40/41: 0.7 bar to 3bar abs. (10.15 psi...43.5 psi abs.) • FMU42/43/44: 0.7 bar to 2.5bar abs. (10.15 psi...36.25 psi abs.)
  • 22. Prosonic M 22 Endress+Hauser Mechanical construction Design; dimensions FMU40, FMU41 A0019317 A F12 housing B T12 housing C FMU40 D FMU41 FMU42, FMU44 with slip-on flange A0019318 A F12 housing B T12 housing C FMU42 D FMU44 65 (2.6) 78 (3.1) ø129(5.1) ~86 (3.4) 78 (3.1) 85 (3.3) 85 (3.3) 65 (2.6) ø129(5.1) 162(6.4) 150(5.9) 68 (2.7) ~148(5.8) ~83(3.3) 22(0.9) C D ø39 (1.5) ø50 (2.0) ~148(5.8) ~87(3.4) 22(0.9) ENDRESS+HAUSER Prosonic M ENDRESS+HAUSER Prosonic M 32 (1.3) A B G 1½" NPT 1½" 94 (3.7) 60 60 G 2" NPT 2" mm (in) ~110(4.3) ø70 (2.8) ~85(3.3) C 65 (2.6) 78 (3.1) ø129(5.1) 86 (3.4) 78 (3.1) 85 (3.3) 65 (2.6) ø129(5.1) 162(6.4) 150(5.9) 68 (2.7) 94 (3.7) ENDRESS+HAUSER Prosonic M ENDRESS+HAUSER Prosonic M 32 (1.3) A B D ø98 (3.9) 07(4.2)~1 ~145(5.7) 85 (3.3) mm (in)
  • 23. Prosonic M Endress+Hauser 23 FMU42, FMU44 with mounting bracket A0019322 A FMU42 ( T12, F12 housing) B FMU44 (T12, F12 housing) 1 M8 FMU43 A0019337 A With slip-on flange (ANSI 4" DN 100) B With mounting bracket (F12 housing) 1 2xM8 Mounting bracket for FMU42, FMU43 and FMU44 A0019342 ENDRESS+HAUSER Prosonic M 75 (3.0) 119 (4.7) 105(4.1) A ENDRESS+HAUSER Prosonic M B 119 (4.7) 30(1.2) 98 (3.9) 125(4.9) 30(1.2) 1 1 mm (in) 85 (3.3) 65 (2.6) 78 (3.1) ø129(5.1) 150(5.9) ~248(9.8) ENDRESS+HAUSER Prosonic M ø230 (9.1) 89 (3.5) A B ~86 (3.4) mm (in) 75(3.0) 158 (6.2) 1 11 (0.43) 119 (4.68) 2 (0.08) 25 (0.98) 120(4.7) ~123(4.8) 40 (1.6) 40 (1.6) mm (in)
  • 24. Prosonic M 24 Endress+Hauser Flanges for FMU42 and FMU44 A0019343 Weight suitable for A B C D E number of boreholes 3" 150 lbs / DN80 PN16 / 10K 80 150 mm (5.91") 160 mm (6.30") 200 mm (7.87") 19 mm (0.75") 45° 8 4" 150 lbs / DN100 PN16 / 10K 100 175 mm (6.90") 190.5 mm (7.50") 228.6 mm (9.00") 19 mm (0.75") 45° 8 6" 150 lbs / DN150 PN16 / 10 K 150 240 mm (9.45") 241.3 mm (9.50") 285 mm (11.22") 23 mm (0.91") 45° 8 8" 150 lbs 298.5 mm (11.75") 298.5 mm (11.75") 342.9 mm (13.50") 22. 5 mm (0.89") 45° 8 DN200 PN16 / 10 K 200 290 mm (11.42") 295 mm (11.61") 340 mm (13.39") 23 mm (0.91") 30° 12 G 2" ISO228 20(0.8) C E A B D mm (in) Sensor Weight kg (lbs) FMU40 approx. 2.5 (5.51) FMU41 approx. 2.6 (5.73) FMU42 approx. 3 (6.62) FMU43 approx. 3.5 (7.72) FMU44 approx. 4 (8.82)
  • 25. Prosonic M Endress+Hauser 25 Housing design Types of housings • F12 housing with sealed terminal compartment for standard or Ex ia applications • T12 housing with separate terminal compartment and explosionproof encapsulation Material Aluminium, powder-coated ( ä 26) Cover • Aluminium, for version without on-site display • Inspection glass for version with on-site display. This version cannot be supplied together with the ATEX II 1/2 D certificate. Process connection Sensor Process connection FMU40 • Thread G 1½“ • Thread NPT 1½“ - 11.5 FMU41 • Thread 2" • Thread NPT 2" - 11.5 FMU42 • Universal flange DN 80 PN16 / ANSI 3" 150 lbs / JIS 10K 80 • Universal flange DN 100 PN16 / ANSI 4" 150 lbs / JIS 10K 100 • Mounting bracket FMU43 • Universal flange DN 100 / ANSI 4" / JIS16K100 • Mounting bracket FMU44 • Universal flange DN 100 PN16 / ANSI 4" 150 lbs / JIS 10K 100 • Universal flange DN 150 PN16 / ANSI 6" 150 lbs / JIS 10K 150 • Universal flange DN200 PN16 / JIS 10K 200 • Flange ANSI 8" 150 lbs • Mounting bracket
  • 26. Prosonic M 26 Endress+Hauser Material (not in contact with process) T12 and F12 housing (powder-coated) A0019273 A T12 housing B F12 housing Note! Seawater-resistant parts please order on request (complete in 316L (1.4404)). A B EN DRESS+HAUSER IP 65 Order Code:Ser.-No .: Messbereich Measuring ran ge U 16...3 6 V DC 4...20 mA ma x. 20 m MadeinGermanyMaulburg T >70°C : A t >85°C MadeinGermanyMaulburg EN DRESS+HAUSER IP 65 Order Code: Ser.-No .: Mess bereich Measuring ran ge U 16...3 6 V DC 4...20 mA ma x. 20 m MadeinGermanyMaulburg T >70°C : A t >85°C 987 5 6 98 5 6 3 2 1 4 2 1 3 3 7 Pos. Part Material 1 T12 and F12 housing AlSi10Mg 2 Cover (Display) AlSi10Mg O-ring EPDM Window ESG-K-Glass Sealing of the glass Silicone sealing compound Gomastit 402 3 Cable gland Polyamid (PA), CuZn nickel-plated O-Ring EPDM Plug PBT-GF30 or 1.0718 galvanized PE or 3.1655 Adapter 316L (1.4435) or AlMgSiPb (anodized) 4 Cover (Connection compartment) AlSi10Mg O-ring EPDM Clamp Screw: A4; Clamp: CuZn nickel-plated; Spring washer: A4 5 O-ring EPDM 6 Tag 304 (1.4301) Rope VA Crimp sleeve Aluminium 7 Nameplate 304 (1.4301) Groove pin A2 8 Ground terminal Screw: A2; Springwasher: A4; Clamp: 304 (1.4301) Holder: 301 (1.4310) 9 Screw A2-70
  • 27. Prosonic M Endress+Hauser 27 Material (in contact with process) A0019054 Note! The chemical compatibility of the sensors must be checked before installation with compatibility charts. Pos. Part A FMU40, FMU41 B FMU42, FMU44 C FMU43 1 Sensor PVDF PVDF UP (Unsaturated polyes- ter resin) 2a Sealing EPDM EPDM or FKM EPDM 2b O-ring EPDM - EPDM 3 Flange - PP, PVDF or stainless steel 316L (1.4435 or 1.4404) 1) 1) Endress+Hauser supplies DIN/EN flanges made of stainless steel AISI 316L with the material number 1.4404 or 1.4435. With regard to their temperature stability properties, the materials 1.4404 and 1.4435 are grouped under 13E0 in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical. PP or 316 Ti (1.4571) 4 Counter nut PC - - 5 Screws - - V2A 6 Thread insert for mounting bracket - - CuZn 7 Sensor membrane - - 316 Ti (1.4571) 8 Mounting bracket (retainer) Screws - - 316 Ti (1.4571) V4A - - 9 Mounting bracket Screws - - 316 Ti (1.4571) V2A 316 Ti (1.4571) V2A 1 2a 3 2a 3 1 1 6 5 9 7 2b A B C C B 8 2a 4 2b 2a
  • 28. Prosonic M 28 Endress+Hauser Operability Display and operating elements The LCD module VU331 for display and operation is located beneath the housing cover. The measured value is legible through the glass in the cover. Open the cover to operate the device. A0019274 1 LCD liquid crystal display 2 Snap fit 3 Keys 4 Symbols Function of the keys ENDRESS + HAUSER E+– 1 2 3 4 Symbol in display continuous flashing Meaning Alarm Warning Communication Security Locking Key(s) Meaning O Navigate upwards in the selection list Edit numeric value within a function S Navigate downwards in the selection list Edit numeric value within a function X Navigate to the left within a function group F Navigate to the right within a function group, confirmation. O and F or S and F Contrast settings of the LCD O and Sand F Hardware lock / unlock After a hardware lock, an operation of the instrument via display or communication is not possible! The hardware can only be unlocked via the display. An unlock parameter must be entered to do so (unlock parameter: 100).
  • 29. Prosonic M Endress+Hauser 29 On-site operation Operation with VU331 The LC-Display VU331 allows configuration via 3 keys directly at the instrument. All device functions can be set through a menu system. The menu consists of function groups and functions. Within a function, application parameters can be read or adjusted. The user is guided through a complete configuration procedure. For ease operation can choose between 7 language: (de: german; en: english; es: spanish; fr: french; it: italian; ja: japanese; nl: dutch). L00-FMU4xxxx-07-00-00-en-004 Operation via Field Xpert SFX100 Compact, flexible and robust industry handheld terminal for remote parametrization and measured value inspection via the HART current output or FOUNDATION Fieldbus. For details refer to Operating Instructions BA00060S/04/EN. Remote operation Operation with FieldCare FieldCare is Endress+Hauser's FDT based Plant Asset Management Tool. It can configure all intelligent field devices in your plant and supports you in managing them. By using status information, it also provides a simple but effective means of checking their health. Hardware and software requirements you can find on the internet: www.endress.com  select your country  search: FieldCare  FieldCare  Technical Data. The FieldCare supports the following functions: • Configuration of transmitters in online operation • Signal analysis via envelope curve • Tank linearization • Loading and saving of instrument data (Upload/Download) • Documentation of measuring point Connection options • HART with Commubox FXA195 and the USB port on a computer • PROFIBUS PA via segment coupler and PROFIBUS interface card • Commubox FXA291 with ToF Adapter FXA291 (USB) via service interface X X X X S S OO FF F F HOME FG00 F000 F001 F002 F003 F004 ... FG01 FG02 FG03 FG04 FG05 FG06 FG07 ... ENDRESS + HAUSER E+– Headline Position indicator Main value UnitSymbol Selection list Function groups -> Functions Help text Envelope curve
  • 30. Prosonic M 30 Endress+Hauser Menu-guided commissioning: L00-FMU4xxxx-19-00-00-en-021 Signal analysis via envelope curve: L00-FMU4xxxx-19-00-00-en-022
  • 31. Prosonic M Endress+Hauser 31 Operation with NI-FBUS Configurator (only FOUNDATION Fieldbus) The NI-FBUS Configurator is an easy-to-use graphical environment for creating linkages, loops, and a schedule based on the fieldbus concepts. You can use the NI-FBUS Configurator to configure a fieldbus network as follows: • Set block and device tags • Set device addresses • Create and edit function block control strategies (function block applications) • Configure vendor-defined function and transducer blocks • Create and edit schedules • Read and write to function block control strategies (function block applications) • Invoke Device Description (DD) methods • Display DD menus • Download a configuration • Verify a configuration and compare it to a saved configuration • Monitor a downloaded configuration • Replace devices • Save and print a configuration Certificates and Approvals CE mark The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms the instrument passing the required tests by attaching the CE-mark. Ex approval The available certificates are listed in the ordering information. Note the associated safety instructions (XA) and control or installation drawings (ZD). External standards and guidelines EN 60529 Protection class of housing (IP-code) EN 61326 series EMC product family standard for electrical equipment for measurement, control and laboratory use NAMUR User association for automation technology in process industries
  • 32. Prosonic M 32 Endress+Hauser Ordering information Product structure FMU40 Versions that mutually exclude one another are not marked. 010 Certificates A Variant for non-hazardous area E NEPSI Ex nA II T6 G ATEX II 3G Ex nA IIC T6 I NEPSI Ex ia IIC T6 J NEPSI Ex d(ia) IIC T6 K TIIS Ex ia II C T6 N CSA General Purpose Q NEPSI DIP S FM IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2 T FM XP Cl. I,II,III Div. 1 Gr. A-G U CSA IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2 V CSA XP Cl. I,II,III Div. 1 Gr. A-G 1 ATEX II 1/2G Ex ia IIC T6 2 ATEX II 1/2D, Alu blind cover 4 ATEX II 1/2G Ex d (ia) IIC T6 5 ATEX II 1/3D 6 ATEX II 3D Ex t IIIC T* °C Dc Y Special certificate 020 Process connection R G 1½“ threadISO 228 N NPT 1½“ - 11,5 thread Y Special version 030 Power supply/communication B 2 wire, 4...20mA-loop/HART H 4 wire, 10,5...32VDC / 4-20mA HART G 4 wire, 90...253VAC / 4-20mA HART D 2 wire, PROFIBUS PA F 2 wire, FOUNDATION Fieldbus J 2-wire; 4-20mA HART, 5-point linearity protocol K 2-wire; PROFIBUS PA, 5-point linearity protocol L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol M 4-wire 90-250VAC; 4-20mA HART,5-point linearity protocol N 4-wire 10.5-32VDC;4-20mA HART,5-point linearity protocol Y Special version 040 Display / on-site operation 1 Without LC display 2 With LC display VU331 incl. on-site operation 3 Prepared for remote display FHX 40 9 Special version 050 Housing A Aluminium F12 housing coated to IP68 NEMA6P C Aluminium T12 housing coated to IP68 NEMA6P; with separate terminal compartment D Aluminium T12 housing coated to IP68 NEMA6P+OVP; with separate terminal compartment; with overvoltage protection 9 Special version
  • 33. Prosonic M Endress+Hauser 33 060 Screw union/entry 2 M20x1.5 screw union 3 G 1/2“ entry 4 NPT 1/2“ entry 5 M12 PROFIBUS-PA plug-in connector 6 7/8" FF plug 9 Special version 995 Marking 1 Tagging (TAG) 2 Bus address FMU40 - Product designation
  • 34. Prosonic M 34 Endress+Hauser Product structure FMU41 010 Certificates A Variant for non-hazardous area E NEPSI Ex nA II T6 G ATEX II 3G Ex nA IIC T6 I NEPSI Ex ia IIC T6 J NEPSI Ex d(ia) IIC T6 K TIIS Ex ia IIC T6 N CSA General Purpose Q NEPSI DIP S FM IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl.I Div.2, zone 0,1,2 T FM XP Cl. I,II,III Div. 1 Gr. A-G / zone 1,2 U CSA IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2, zone 0,1,2 V CSA XP Cl. I,II,III Div. 1 Gr. A-G / zone 1,2 1 ATEX II 1/2G Ex ia IIC T6 2 ATEX II 1/2D, Alu blind cover 4 ATEX II 1/2G Ex d (ia) IIC T6 5 ATEX II 1/3D 6 ATEX II 3D Ex t IIIC T* °C Dc Y Special certificate 020 Process connection R G 2“ threadISO 228 N NPT 2“ - 11,5 thread Y Special version 030 Power supply/communication B 2 wire, 4...20mA-loop/HART H 4 wire, 10,5...32VDC / 4-20mA HART G 4 wire, 90...253VAC / 4-20mA HART D 2 wire, PROFIBUS PA F 2 wire, FOUNDATION Fieldbus J 2-wire; 4-20mA HART, 5-point linearity protocol K 2-wire; PROFIBUS PA, 5-point linearity protocol L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol M 4-wire 90-250VAC; 4-20mA HART,5-point linearity protocol N 4-wire 10.5-32VDC;4-20mA HART,5-point linearity protocol Y Special version 040 Display / on-site operation 1 Without LC display 2 With LC display VU331 incl. on-site operation 3 Prepared for remote display FHX 40 9 Special version 050 Housing A Aluminium F12 housing coated to IP68 NEMA 6P C Aluminium T12 housing coated to IP68 NEMA 6P; with separate terminal compartment D Aluminium T12 housing coated to IP68 NEMA 6P; with separate terminal compartment; with overvoltage protection 9 Special version 060 Screw union/entry 2 M20x1.5 screw union 3 G 1/2“ entry 4 NPT 1/2“ entry 5 M12 PROFIBUS-PA plug-in connector 6 7/8" FF plug 9 Special version 995 Marking 1 Tagging (TAG) 2 Bus address FMU41 - Product designation
  • 35. Prosonic M Endress+Hauser 35 Product structure FMU42 010 Certificates A Variant for non-hazardous area E NEPSI Ex nA II T6 G ATEX II 3G Ex nA IIC T6 I NEPSI Ex ia IIC T6 J NEPSI Ex d (ia) IIC T6 K TIIS Ex ia II C T6 (in preparation) N CSA General Purpose Q NEPSI DIP S FM IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2 T FM XP Cl. I,II,III Div. 1 Gr. A-G U CSA IS Cl. I,II,III Div. 1 Gr. A-G / NI Cl. I Div. 2 V CSA XP Cl. I,II,III Div. 1 Gr. A-G 1 ATEX II 1/2 G Ex ia IIC T6 2 ATEX II 1/2 D, Alu blind cover 4 ATEX II 1/2 G Ex d [ia] IIC T6 5 ATEX II 1/3D 6 ATEX II 3D Ex t IIIC T* °C Dc Y Special certificate 020 Process connection M Mounting bracket FAU20 P UNI flange 3"/DN80/80, PP, max. 2.5bar abs./ 36psia suitable for 3" 150lbs / DN80 PN16 / 10K 80 Q UNI flange 3"/DN80/80, PVDF, max. 2.5bar abs./ 36psia suitable for 3" 150lbs / DN80 PN16 / 10K 80 S UNI flange 3"/DN80/80, 316L, max. 2.5bar abs./ 36psia suitable for 3" 150lbs / DN80 PN16 / 10K 80 T UNI flange 4"/DN100/100, PP, max. 2.5bar abs./ 36psia suitable for 4" 150lbs / DN100 PN16 / 10K100 U UNI flange 4"/DN100/100, PVDF, max. 2.5bar abs./ 36psia suitable for 4" 150lbs / DN100 PN16 / 10K100 V UNI flange 4"/DN100/100, 316L, max. 2.5bar abs./ 36psia suitable for 4" 150lbs / DN100 PN16 / 10K100 Y Special version 030 Power supply/communication B 2 wire, 4...20mA-loop/HART H 4 wire, 10,5...32VDC / 4-20mA HART G 4 wire, 90...253VAC / 4-20mA HART D 2 wire, PROFIBUS PA F 2 wire, FOUNDATION Fieldbus J 2-wire; 4-20mA HART, 5-point linearity protocol K 2-wire; PROFIBUS PA, 5-point linearity protocol L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol M 4-wire 90-250VAC; 4-20mA HART,5-point linearity protocol N 4-wire 10.5-32VDC;4-20mA HART,5-point linearity protocol Y Special version 040 Display / on-site operation 1 Without LC display 2 With LC display VU331 incl. on-site operation 3 Prepared for remote display FHX40 9 Special version 050 Housing A Aluminium F12 housing coated to IP68 NEMA 6P C Aluminium T12 housing coated to IP68 NEMA 6P, with separate terminal compartment D Aluminium T 12 housing coated to IP68 NEMA 6P, with separate terminal compartment; with overvoltage protection Y Special version 060 Gland/Entry 2 M20x1.5 gland 3 G 1/2“ entry 4 NPT 1/2“ entry
  • 36. Prosonic M 36 Endress+Hauser 5 M12 PROFIBUS-PA plug 6 7/8" FF plug 9 Special version 070 Sealing Sensor/Flange 2 VITON flat sealing 3 EPDM flat sealing 9 special version 080 Additional options A Additional options not selected 995 Marking 1 Tagging (TAG) 2 Bus address FMU42 - Product designation 060 Gland/Entry
  • 37. Prosonic M Endress+Hauser 37 Product structure FMU43 010 Certificates A Variant for non-hazardous area 2 ATEX II 1/2D, Alu blind cover 5 ATEX II 1/3D 6 ATEX II 3D Ex t IIIC T* °C Dc M FM DIP Cl.II Div.1 Gr.E-G, NI Cl.I Div.2, Zone 2 N CSA General Purpose P CSA DIP Cl.II Div.1 Gr.E-G, NI Cl.I Div.2, zone 2 Q NEPSI DIP Y Special version 020 Process connection/material P Flange DN 100/ANSI 4"/JIS 16K100, PP (universal slip-on flange included) S Flange DN 100/ANSI 4"/JIS 16K100, SS 316TI (universal slip-on flange included) K Without slip-on flange/without mounting bracket (customer mounting equipment) M With mounting bracket FAU20 Y Special version 030 Power supply/communication H 4 wire, 10,5...32VDC / 4-20mA HART G 4 wire, 90...253VAC / 4-20mA HART D 2 wire, PROFIBUS PA F 2 wire, FOUNDATION Fieldbus J 2-wire; 4-20mA HART, 5-point linearity protocol K 2-wire; PROFIBUS PA, 5-point linearity protocol L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol M 4-wire 90-250VAC; 4-20mA HART, 5-point linearity protocol N 4-wire 10.5-32VDC;4-20mA HART, 5-point linearity protocol Y Special version 040 Display / on-site operation 1 Without LC display 2 4-line display VU331, Envelope curve display on site 3 Prepared for remote display FHX 40 9 Special version 050 Housing A Aluminium F12 housing coated to IP68 NEMA 6P 9 Special version 060 Screw union/entry 2 M20x1.5 screw union 3 G 1/2“ entry 4 NPT 1/2“ entry 5 M12 PROFIBUS-PA plug-in connector 6 7/8" FF plug 9 Special version 995 Marking 1 Tagging (TAG) 2 Bus address FMU43 - Product designation
  • 38. Prosonic M 38 Endress+Hauser Product structure FMU44 010 Approval A Non-hazardous area 1 ATEX II 1/2G Ex ia IIC T6 4 ATEX II 1/2G Ex d (ia) IIC T6 G ATEX II 3G Ex nA IIC T6 Gc 2 ATEX II 1/2 D, Alu blind cover 5 ATEX II 1/3 D 6 ATEX II 3D Ex t IIIC T* °C Dc S FM IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.I Div.2, Zone 0,1,2 (in preparation) T FM XP Cl.I,II,III Div.1 Gr.A-G, Zone 1,2 (in preparation) N CSA General Purpose U CSA IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.I Div.2, zone 0,1,2 V CSA XP Cl.I,II,III Div.1 Gr.A-G K TIIS Ex ia IIC T6 (in preparation) I NEPSI Ex ia IIC T6 (in preparation) J NEPSI Ex d(ia) IIC T6 (in preparation) E NEPSI Ex nA II T6 (in preparation) Q NEPSI DIP (in preparation) Y Special version, to be specified 020 Process connection A 8" 150lbs FF, 316L, max 2.5bar abs./36psia E UNI flange 6"/DN150/150, PP, max 2.5bar abs./ 36psia, suitable for 6" 150lbs / DN150 PN16 / 10K 150 F UNI flange 6"/DN150/150, PVDF, max 2.5bar abs./36psia, suitable for 6" 150lbs /DN150 PN16 / 10K 150 G UNI flange 6"/DN150/150, 316L, max 2.5bar abs. 36psia, suitable for 6" 150lbs / DN150 PN16 / 10K 150 H UNI flange DN200/200, PP, max 2.5bar abs./ 36 psia, suitable for DN200 PN16 / 10K 200 J UNI flange DN200/200, PVDF, max 2.5bar abs./ 36psia, suitable for DN200 PN16 / 10K 200 K UNI flange DN200/200, 316L, max 2.5bar abs./ 36psia, suitable for DN200 PN16 / 10K 200 L 8" 150lbs FF, PP, max 2.5bar abs./ 36psia M Mounting bracket FAU20 N 8" 150lbs FF, PVDF, max 2.5bar abs./ 36psia T UNI flange 4"/DN100/100, PP, max 2.5bar abs./ 36psia, suitable for 4" 150lbs / DN100 PN16 / 10K 100 U UNI flange 4"/DN100/100, PVDF, max. 2.5bar abs./ 36 psia, suitable for 4" 150lbs / DN100 PN16 / 10K 100 V UNI flange 4"/DN100/100, 316L, max 2.5bar abs./ 36psia, suitable for 4" 150lbs / DN100 PN16 / 10K 100 Y Special version, to be specified 030 Power supply; Output B 2-wire; 4-20mA HART D 2-wire; PROFIBUS PA F 2-wire; FOUNDATION Fieldbus G 4-wire 90-250VAC; 4-20mA HART H 4-wire 10.5-32VDC; 4-20mA HART J 2-wire; 4-20mA HART, 5-point linearity protocol K 2-wire; PROFIBUS PA, 5-point linearity protocol L 2-wire; FOUNDATION Fieldbus, 5-point linearity protocol M 4-wire 90-250VAC; 4-20mA HART, 5-point linearity protocol N 4-wire 10.5-32VDC;4-20mA HART, 5-point linearity protocol Y Special version, to be specified 040 Operation 1 w/o display, via communication 2 4-line display VU331, Envelope curve display on site 3 Prepared for FHX40, Remote display (accessory) 9 Special version, to be specified FMU44 - product designation, part 1
  • 39. Prosonic M Endress+Hauser 39 050 Housing A F12 Alu, coated IP68 NEMA6P C T12 Alu, coated IP68 NEMA6P, Separate conn. compartment D T12 Alu, coated IP68 NEMA6P + OVP, Sep. conn. compartment, OVP = overvoltage protection 9 Special version, to be specified 060 Cable entry 2 Gland M20 (Ex d > thread M20) 3 Thread G1/2 4 Thread NPT 1/2 5 Plug M12 6 Plug 7/8“ 9 Special version, to be specified 070 Process Sealing Sensor/ Flange 2 Viton 3 EPDM 9 Special version, to be specified 080 Additional option A Basic version Y Special version, to be specified 995 Marking 1 Tagging (TAG) 2 Bus address FMU44 - complete product designation
  • 40. Prosonic M 40 Endress+Hauser 5-point linearity protocol The following must be taken into account if option "5 point linearity protocol" has been selected: • The five points of the linearity protocol are evenly distributed across the measuring range (0 % to 100 %). In order to define the measuring range, Empty calibration (E) and Full calibration (F) have to be specified.3) • The following restrictions have to be taken into account when defining E and F: A0019522 Note! The linearity is checked under reference conditions. Scope of delivery • Instrument according to the version ordered • Endress+Hauser operating program on the enclosed CD-ROM • Brief operating instructions according to the communication version • For certified instrument versions: Safety Instructions, Control- or Installation drawings • For FMU40 *R**** and FMU41 *R****: counter nut (PC) • For FMU40/41: sealing ring (EPDM) • For gland M20x1.5: – 1 cable gland for 2-wire instruments – 2 cable glands for 4-wire instruments The cable glands are mounted on delivery. • CD-ROM with further documentation, e.g. Operating Instructions, Description of Intrument Functions 3) If the values for the full calibration and empty calibration are missing or outside the specified area, the devices are tested with the maximum value according to the table. Pos. Measuring range FMU40 FMU41 FMU42 FMU43 FMU44 E Maximum value for the empty calibration 5000 (197) 8000 (315) 10000 (394) 15000 (591) 20000 (787) F Maximum value for the full calibration 4750 (187) 7500 (295) 9600 (378) 14400 (567) 19500 (768) S Minimum span E-F 100 (3.94) 100 (3.94) 100 (3.94) 150 (591) 250 (9.84) A Minimum distance between reference point R from sensor and 100 % level 250 (9.84) 500 (19.7) 400 (15.7) 600 (23.6) 500 (19.7) mm (in) R AF mm (in) E S
  • 41. Prosonic M Endress+Hauser 41 Accessories Weather protection cover A Weather protection cover made of stainless steel is recommended for outdoor mounting. The shipment includes the protective cover and tension clamp. A0019345 A F12 housing, T12 housing Installation bracket for FMU40, FMU41 A0019346 MadeinGermanyMaulburgMadeinGermanyMaulburg A 70 (2.76) mm (in) 240 (9.45) 135 (5.31) 95(3.74) 45° Part Order No. Material Protective cover, tension clamp 543199-0001 304 (1.4301) Screw, nut, disk A2 Sensor Order No. Material Weight FMU40, G 1½" 942669-0000 316 Ti (1.4571) 3.4 kg (7.5 lbs) FMU41, G 2" 942669-0001 Suited for NPT 1½" and 2" as well 400 (15.7) 120 (4.72) 120 (4.72) 30(1.2) 250(9.84) G ø16 (0.6) 3 (0.12) mm (in)
  • 42. Prosonic M 42 Endress+Hauser Screw in flange A0019281 1 Screw in flange 2 Nozzle 3 Sensor 4 Sealing ring EPDM (supplied) Screw in flange FAX50 4 1 3 2 015 Material: BR1 DN50 PN10/16 A, steel flange EN1092-1 BS1 DN80 PN10/16 A, steel flange EN1092-1 BT1 DN100 PN10/16 A, steel flange EN1092-1 JF1 2" 150lbs FF, steel flange ANSI B16.5 JG1 3" 150lbs FF, steel flange ANSI B16.5 JH1 4" 150lbs FF, steel flange ANSI B16.5 JK2 8" 150lbs FF, PP max 3bar abs/44psia flange ANSI B16.5 XIF UNI flange 2"/DN50/50, PVDF max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50 XIG UNI flange 2"/DN50/50, PP max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50 XIJ UNI flange 2"/DN50/50, 316L max 4bar abs/58psia, suitable for 2" 150lbs/DN50 PN16/10K 50 XJF UNI flange 3"/DN80/80, PVDF max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80 XJG UNI flange 3"/DN80/80, PP max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80 XJJ UNI flange 3"/DN80/80, 316L max 4bar abs/58psia, suitable for 3" 150lbs/DN80 PN16/10K 80 XKF UNI flange 4"/DN100/100, PVDF max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100 XKG UNI flange 4"/DN100/100, PP max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100 XKJ UNI flange 4"/DN100/100, 316L max 4bar abs/58psia, suitable for 4" 150lbs/DN100 PN16/10K 100 XLF UNI flange 6"/DN150/150, PVDF max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150 XLG UNI flange 6"/DN150/150, PP max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150 XLJ UNI flange 6"/DN150/150, 316L max 4bar abs/58psia, suitable for 6" 150lbs/DN150 PN16/10K 150 XMG UNI flange DN200/200, PP max 4bar abs/58psia, suitable for DN200 PN16/10K 200 XNG UNI flange DN250/250, PP max 4bar abs/58psia, suitable for DN250 PN16/10K 250 YYY Special version 020 Sensor Connection: A Thread ISO228 G3/4 B Thread ISO228 G1 C Thread ISO228 G1-1/2 D Thread ISO228 G2 E Thread ANSI NPT3/4 F Thread ANSI NPT1 G Thread ANSI NPT1-1/2 H Thread ANSI NPT2 Y Special version 015 020 FAX50 -
  • 43. Prosonic M Endress+Hauser 43 Cantilever with mounting frame or wall bracket A0019523 A Installation with cantilever and wall bracket B Installation with cantilever and mounting frame 1 Cantilever 2 Mounting frame 3 Wall bracket Cantilever A0019349 • The 50 mm (1.97 in) or 62 mm (2.44 in) orifices serve for the mounting of the FMU40 or FMU41 sensor, respectively. • The 22 mm (0.87 in) orifice may be used for an additional sensor. Fixing screws are supplied. ENDRESS+HAUSER ProsonicM ENDRESS+HAUSER ProsonicM 3 1 2 A B 1 A B C D Weight for Sensor Material Order Code 585 (23) 250 (9.84) 2 (0.08) 200 (7.87) 1.9 kg (4.2 lbs) FMU40 316Ti (1.4571) 52014132 galv. steel 52014131 FMU41 316Ti (1.4571) 52014136 galv. steel 52014135 1085 (42.7) 750 (29.5) 3 (0.12) 300 (11.8) 4.4 kg (9.7 lbs) FMU40 316Ti (1.4571) 52014134 galv. steel 52014133 FMU41 316Ti (1.4571) 52014138 galv. steel 52014137 mm (in) A D M8 35 (1.4) 50(2.0) 20(0.8) 105(4.1) 50/62 (2.0/2.4) 22(0.9) C C 6.5(0.3) 15(0.6) 100(3.9) 25(1.0) 35 (1.4)100 (3.9)75 (2.9) B 20(0.8) 75 (2.9) mm (in)
  • 44. Prosonic M 44 Endress+Hauser Mounting Frame A0019279 Wall Bracket A0019350 Height Material Weight Order Code 700 (27.6) galv. steel 3.2 kg (7.06 lbs) 919791-0000 700 (27.6) 316Ti (1.4571) 919791-0001 1400 (55.1) galv. steel 4.9 kg (10,08 lbs) 919791-0002 1400 (55.1) 316Ti (1.4571) 919791-0003 mm (in) Material Weight Order Code galv. steel 1.4 kg (3.09 lbs) 919792-0000 316Ti (1.4571) 919792-0001 3.2 (0.13) 20 (0.8) 55 (2.17) 100(3.94) 25(0.98) 700/1400 (27.6/55.1) 45(1.77) 76 (2.99) 100 (3.94) 200(7.87) 13(0.5) ø33.7 (1.3) 130 (5.12) 150 (5.91) 100 (3.94) 60 (2.36) 4 (0.16) 6.5(0.3)mm (in) 110 (4.3) 25 (1.0) 5 (0.2) 6.5 (0.3) 150 (5.9) ø33.7 (1.3) 3.2 (0.1) 110(4.3) 13(0.5) 150(5.9) 180(7.1) ~213(8.4) ~ (3.5)88 mm (in)
  • 45. Prosonic M Endress+Hauser 45 Commubox FXA195 HART For intrinsically safe communication with FieldCare via the USB interface. For details refer to TI00404F/00/EN. Commubox FXA291 The Commubox FXA291 connects Endress+Hauser field instruments via the service interface to the USB interface of a personal computer or a notebook. For details refer to TI00405C/07/EN. Note! For the instrument you need the "ToF Adapter FXA291" as an additional accessory. ToF Adapter FXA291 The ToF Adapter FXA291 connects the Commubox FXA291 via the USB interface of a personal computer or a notebook to the instrument. For details refer to KA00271F/00/A2. Remote display FHX40 A0019277 A Wall mounting (without mounting bracket) B Pipe mounting (mounting bracket and plate supplied optionally, see product structure) 1 Prosonic M, Levelflex M, Micropilot M 2 Separate housing FHX40 (IP65) 3 Cable 4 Pipe For the device families Micropilot FMR2xx, Levelflex FMP4x and Prosonic FMU4x, the remote display FHX40 must be only used for the HART communication version. For more details, see KA00202F/00/C4. Order information FHX40 MadeinGermanyMaulburg 82 (3.23)6.3 106(4.71) 122(4.8) 120 (4.72) mm (in) max. 80 (3.15) min. 30 (1.18) 96 (3.78) 88 (3.46) 160(6.3) 118 (4.65) 180(7.09) 1 122 (4.8) 80(3.51) 2 3 A B 4 150 (5.91) 8.5(0.33) (0.25) 010 Approval: A Non-hazardous area 2 ATEX II 2G Ex ia IIC T6 3 ATEX II 2D Ex ia IIIC T80°C G IECEx Zone1 Ex ia IIC T6/T5 S FM IS Cl. I Div.1 Gr. A-D, zone 0 U CSA IS Cl. I Div.1 Gr. A-D, zone 0 N CSA General Purpose K TIIS Ex ia IIC T6 C NEPSI Ex ia IIC T6/T5 Y Special version, TSP-Nr. to be spec. 020 Cable: 1 20 m/65 ft: for HART 5 20 m/65 ft: for PROFIBUS PA, FOUNDATION Fieldbus 9 Special version, TSP-Nr. to be spec. 030 Additional option: A Basic version B Mounting bracket, pipe 1"/ 2"
  • 46. Prosonic M 46 Endress+Hauser For connection of the remote display FHX40 use the cable which fits the communication version of the respective instrument. Technical data (cable and housing): Materials A0019282 Y Special version, TSP-Nr. to be spec. 995 Marking: 1 Tagging (TAG) FHX40 - Complete product designation Max. cable length 20 m (65 ft) Temperature range –40 to +60 °C (–40 to +140 °F) for temperature class T6 –40 to +75 °C (–40 to +167 °F) for temperature class T5 Degree of protection IP65/67 (housing); IP68 (cable) acc. to IEC 60529 Dimensions mm (in), (HxWxD) 122x150x80 (4.8x5.9x3.2) Position Part Material 1 Housing/Cover AlSi12, Screw: V2A Ground terminal CuZn nickel-plated, Screw: V2A 2 Display Glass 3 Cable gland CuZn nickel-plated 4 Cable PVC 5 Mounting bracket 316 Ti (1.4571) or 316 L (1.4435) or 316 (1.4401) 6 Nut V4A 7 Plate Screw set (M5) 316 Ti (1.4571) Spring washer: 301 (1.4310) or V2A Screw: V4A, Nut: V4A 030 Additional option: MadeinGerMadeinGermanmanyMaulbyMaulburgurg 4 1 2 3 6 7 53
  • 47. Prosonic M Endress+Hauser 47 Documentation This documentation can be found on our product pages on  www.en.endress.com  download Operating manual • BA00237F (4 to 20mA, HART) • BA00238F (PROFIBUS PA) • BA00239F (FOUNDATION Fieldbus) The documentations can be found on the on the enclosed CD-ROM. These instructions describe the installation and first commissioning of the Prosonic M. From the operating menu, all functions are included, which are required for standard measurement tasks. Additional functions are not contained in the manual. Description of device functions BA00240F This contains a detailed description of all the functions of the Prosonic M and is valid for all communication variants.The documentations can be found on the on the enclosed CD-ROM. Short instructions The following short instruction are supplied according to the communication version: • KA01062F (4 to 20mA, HART) • KA01063F (PROFIBUS PA) • KA01064F (FOUNDATION Fieldbus) These instructions describe the installation and first quick commissioning of the Prosonic M. KA00183F Can be found under the device housing cover. The most important menu functions are summarised on this sheet. It is intended primarily as a memory jogger for users who are familiar with the operating concept of Endress+Hauser time-of-flight instruments.
  • 48. Prosonic M 48 Endress+Hauser Safety Instructions ATEX The following safety instructions are supplied with ATEX-certified device versions. If the devices are used in explosive areas, comply with all the specifications in these safety instructions. Instrument version Certificate Communication Housing Safety Instructions • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... ATEX II 1/2 G Ex ia IIC T4...T6 II 2 G Ex ia IIC T4...T6 HART (2-wire) F12 XA00174F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... ATEX II 1/2 G Ex ia IIC T4...T6 II 2 G Ex ia IIC T4...T6 HART (2-wire) T12 with overvoltage protection XA00224F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... ATEXII 1/2 G Ex ia IIC T4...T6 II 2 G Ex ia IIC T4...T6 • PROFIBUS PA • FOUNDATION Fieldbus F12 XA00175F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... ATEX II 1/2 G Ex ia IIC T4...T6 II 2 G Ex ia IIC T4...T6 • PROFIBUS PA • FOUNDATION Fieldbus T12 with overvoltage protection XA00225F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... ATEX II 1/2 G Ex d[ia] IIC T4...T6 II 2 G Ex d[ia] IIC T4...T6 • HART (2-wire) • PROFIBUS PA • FOUNDATION Fieldbus T12 XA00176F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU43 - ... • FMU44 - ... • ATEX II 3D Ex t IIC Txx °C Dc • ATEX II 3G Ex nA IIC T6 Gc • HART (2-wire) • HART (4-wire, DC) • HART (4-wire, AC) • PROFIBUS PA • FOUNDATION Fieldbus • F12 • T12 • T12 with overvoltage protection XA00179F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... • ATEX II 1/2 D, II 2 D Ex tD ... IP6X T95°C • ATEX II 1/3 D, II 3 D Ex tD ... IP6X T95°C • HART (2-wire) • PROFIBUS PA • FOUNDATION Fieldbus F12 XA00180F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... • ATEX II 1/2 D, II 2 D Ex tD ... IP6X T115°C • ATEX II 1/3 D, II 3 D Ex tD ... IP6X T100°C • HART (4-wire, DC) • HART (4-wire, AC) F12 XA00259 • FMU43 - ... • ATEX II 1/2 D bzw. II 2 D • ATEX II 1/3 D bzw. II 3 D • HART (4-wire, DC) • HART (4-wire, AC) F12 XA00177F • FMU43 - ... • ATEX II 1/2 D bzw. II 2 D • ATEX II 1/3 D bzw. II 3 D • PROFIBUS PA • FOUNDATION Fieldbus F12 XA00178F
  • 49. Prosonic M Endress+Hauser 49 Safety Instructions NEPSI The following safety instructions are supplied with NEPSI-certified device versions. If the devices are used in explosive areas, comply with all the specifications in these safety instructions. Instrument version Certificate Communication Housing Safety Instructions • FMU40 - ... • FMU41 - ... • FMU42 - ... Ex ia IIC T1 ... T6 NEPSI GYJ071468 HART (2-wire) F12 XA00436F • FMU40 - ... • FMU41 - ... • FMU42 - ... Ex ia IIC T1 ... T6 NEPSI GYJ071468 HART (2-wire) T12 with overvoltage protection XA00442F • FMU40 - ... • FMU41 - ... • FMU42 - ... Ex ia IIC T1 ... T6 NEPSI GYK071468 • PROFIBUS PA • FOUNDATION Fieldbus F12 XA00437F • FMU40 - ... • FMU41 - ... • FMU42 - ... Ex ia IIC T1 ... T6 NEPSI GYJ071468 • PROFIBUS PA • FOUNDATION Fieldbus T12 with overvoltage protection XA00443F • FMU40 - ... • FMU41 - ... • FMU42 - ... Ex d [ia] IIC T1 ... T6 NEPSI GYJ071468 • HART (2-wire) • PROFIBUS PA • FOUNDATION Fieldbus T12 XA00438F • FMU40 - ... • FMU41 - ... • FMU42 - ... DIP A21/A22 TA, T* NEPSI GYJ071468 • HART (2-wire) • PROFIBUS PA • FOUNDATION Fieldbus F12 XA00441F • FMU40 - ... • FMU41 - ... • FMU42 - ... DIP A21/A22 TA, T* NEPSI GYJ071468 • HART (4-wire, DC) • HART (4-wire, AC) F12 XA00444F • FMU43 - ... DIP A21/A22 TA, T* NEPSI GYJ071469 • HART (4-wire, DC) • HART (4-wire, AC) F12 XA00439F • FMU43 - ... DIP A21/A22 TA, T* NEPSI GYJ071469 • PROFIBUS PA • FOUNDATION Fieldbus F12 XA00440F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... Ex nA IIC T6...T3 Gc NEPSI GYJ12.1452 • HART • PROFIBUS PA • FOUNDATION Fieldbus • F12 • T12 • F23 XA00403F
  • 50. Prosonic M 50 Endress+Hauser Control drawings Installation drawings The following control or installation drawings are supplied with the FM, CSA and TIIS-certified device versions: Instrument version Certificate Communication Housing Control or Installation Drawing • FMU40 - ... • FMU41 - ... • FMU42 - ... FM IS HART (2-wire) F12 ZD00096F • FMU40 - ... • FMU41 - ... • FMU42 - ... FM IS • PROFIBUS PA • FOUNDATION Fieldbus F12 ZD00097F • FMU40 - ... • FMU41 - ... • FMU42 - ... FM IS HART (2-wire) T12 with overvoltage protection ZD00139F • FMU40 - ... • FMU41 - ... • FMU42 - ... FM IS • PROFIBUS PA • FOUNDATION Fieldbus T12 with overvoltage protection ZD00140F • FMU40 - ... • FMU41 - ... • FMU42 - ... FM XP • HART (2-wire) • PROFIBUS PA • FOUNDATION Fieldbus T12 ZD00098F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... CSA IS HART (2-wire) F12 ZD00088F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... CSA IS • PROFIBUS PA • FOUNDATION Fieldbus F12 ZD00099F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... CSA IS HART (2-wire) T12 with overvoltage protection ZD00101F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... CSA IS • PROFIBUS PA • FOUNDATION Fieldbus T12 with overvoltage protection ZD00102F • FMU40 - ... • FMU41 - ... • FMU42 - ... • FMU44 - ... CSA XP • HART (2-wire) • PROFIBUS PA • FOUNDATION Fieldbus T12 ZD00100F • FMU40 - ... • FMU41 - ... TIIS Ex ia IIC T6 HART (2-wire) F12 ZD00138F
  • 52. Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI00365F/00/EN/15.12 71197996 FM+SGML 9.0 7119799671197996