Redbooks Paper
                                                                                                  Steve Strutt


Enhancing IBM Tivoli SAN Manager
Device Availability Alerting

Introduction
                This Redpaper outlines how it is possible to enhance the real-time alerting of the availability
                status of SAN devices with the IBM® Tivoli® Storage Area Network Manager SAN
                management solution. The approach outlined here uses the industry standard FC Mgmt MIB
                implemented by most SAN devices to report device status information, irrespective of device
                type or vendor. The FC Mgmt MIB was originally created for just this task, providing for the
                reporting of device events, and monitoring and alerting on device and port status information,
                device internal temperature, and the availability of power supplies and fans.

                To minimize administrative effort, many organizations use event management consoles to
                monitor and manage their whole IT infrastructure on an exception management basis.
                Operations personnel can be alerted in real time to all issues relating to application
                availability. This also enables the use of a single consistent approach to alert and event
                management across the whole of IT, simplifying administration and reducing costs. The
                exploitation of the FC Mgmt MIB for the reporting of status and events enables SAN device
                availability information to be included as part of end-to-end application management. It helps
                ensure storage and application availability and reduces the risk of application outages by
                simplifying the job of storage administrators or operations personnel in monitoring and
                maintaining SAN devices.

                Accompanying scripts are provided to implement the features described in this paper. These
                scripts can be downloaded (in a ZIP archive called custom.zip) from the following URL:
                   ftp://www.redbooks.ibm.com/redbooks/REDP3821/

                Alternatively, you can go to the IBM Redbooks™ Web site at:
                   http://ibm.com/redbooks

                Select Additional materials and open the directory that corresponds with the Redpaper form
                number, REDP3821.




© Copyright IBM Corp. 2004. All rights reserved.                                       ibm.com/redbooks       1
Tivoli Storage Area Network Manager and availability alerting
               IBM Tivoli Storage Area Network Manager centralizes the management of a SAN fabric by
               bringing SAN topology discovery, mapping, and availability alerting to a central point. SAN
               topology is displayed on the SAN Manager console, which is updated in real time with the
               availability of the SAN fabric network. In addition, it provides alerting of changes in SAN
               topology and configuration through Simple Network Management Protocol (SNMP) traps and
               Tivoli Enterprise™ Console events. These topology change events are an essential part of a
               storage availability management solution. They enable administrators to identify changes that
               might have an impact on applications and enable rapid identification of the cause of
               application failures.

               To ensure high availability, many devices include redundant components such as power
               supplies and fans, because these electro-mechanical components have a relatively short life
               compared to any internal electronics. The individual failure of these components will not
               cause device failure, but will increase the exposure to the risk of further failures resulting in
               complete device failure, causing a significant SAN failure and availability issue.

               Currently, Tivoli Storage Area Network Manager alerts on the availability of the SAN fabric
               and the up or down status of the devices of which the fabric comprises. It does not alert on
               the health or availability status of individual SAN devices and internal components that are a
               working part of the SAN fabric. Only if a device fails will Tivoli Storage Area Network Manager
               alert that it has been removed from the fabric. Note that TSNAM does monitor the underlying
               health of the Fibre Channel links to predict an impending hard failure of the data transmission
               path. This function is the SAN Error Predictor doing Error Detection and Fault Isolation
               (ED/FI). The addition of availability status alerting using the FC Mgmt MIB as outlined in this
               paper enables the real-time detection of device failures or events that could impact the
               availability of a device, but have not yet caused the device to fail. This is particularly critical
               where redundant components are concerned.

               Figure 1 shows the overall structure of this device availability alerting solution. IBM Tivoli
               NetView® receives FC Mgmt MIB traps from devices and forwards these to Tivoli Storage
               Area Network Manager and additionally sends formatted FC Mgmt MIB events as SNMP
               traps to the NetView event log and as Tivoli Enterprise Console® events to the Tivoli
               Enterprise Console. Tivoli Storage Area Network Manager monitors the fabric topology, using
               the traps from NetView and in-band fabric events to trigger topology refreshes, and sends
               fabric availability events to a Tivoli Enterprise Console and the NetView event log.


                                                        Topology/
                              NetView                  Configuration      TSANM
                             Event Log                   events          TEC event



                                                                       FC Mgmt
                                          FC Mgmt                      TEC event      Tivoli
                                           SNMP         TSANM                         Enterprise
                   SAN      FC Mgmt         traps       Console                       Console
                 Switches    SNMP
                              traps       Tivoli
                                         NetView                       TSANM Windows 2000
                                                                       Mgmt Server



               Figure 1 Tivoli Storage Area Network Manager and device availability alerting

               The addition of this capability to Tivoli Storage Area Network Manager provides an enhanced
               real-time availability monitoring and alerting solution for SAN fabrics and SAN components.


2   Enhancing IBM Tivoli SAN Manager Device Availability Alerting
Tivoli Storage Area Network Manager alerts on the availability of the SAN fabric itself and the
           FC Mgmt traps on SAN device health and availability.

           Fabric and SAN availability alerting is only one part of end-to-end storage availability
           monitoring and management. To provide a comprehensive view of availability, information
           about all aspects of storage infrastructure that have a bearing on the availability of the LUNs
           and file systems used by applications must be integrated into a management solution. Table 1
           shows the IBM software and hardware products which can be integrated into a single
           end-to-end storage availability management solution for IBM TotalStorage® environments.

           Table 1 Components of an IBM end-to-end storage availability monitoring solution
            Event source                             Storage             Types of events
                                                     component

            Storage device

            Tape storage (3494, 359x)                Device - Tape       Availability

            Disk storage (ESS, SVC, FAStT)           Device - Disk       Availability

            SAN switches                             Device - SAN        Availability

            Storage application

            Tivoli NetView                           Device - SAN        Availability
            Device FC Mgmt traps

            Tivoli Storage Area Network Manager      Storage Network     Availability

            Tivoli Storage Area Network Manager -    Device - SAN        Errors
            SAN Error Predictor

            Tivoli Storage Resource Manager          LUNs                Availability

                                                     File systems        Availability, Utilization

           The solution outlined here using FC Mgmt traps and NetView adds a key component to this,
           namely the alerting on SAN device availability and status.


The alerting solution
           The FC Mgmt MIB definition includes four SNMP traps to indicate significant device events or
           a change in status of the device. The events and the information they impart are:
              Device state and status: Online/Offline, OK/Warning/Failed
              Environmental Sensors: Temperature, Power Supplies, Fans: OK/Warning/Failed
              Port Status: Online/Offline, OK/Warning/Failure
              Device Events: Internal device event details

           The FC Mgmt MIB trap information, as received by NetView, is largely as integer values to
           represent status information, not a textual description. In some cases, only the bare minimum
           of information is passed in the trap and is insufficient to completely identify the failing
           component or the severity of the event. To be useful, the integer values have to be converted
           to readable text and additional information retrieved from the device to make an alert that is
           easily readable and contains sufficient information to help determine the severity of the
           problem. This solution performs these functions, interpreting the events and querying the
           devices for more information to make the events more descriptive and useful.

           A number of elements on the Tivoli Storage Area Network Manager management server are
           used to implement this availability monitoring and alerting solution. As shown in Figure 1, the


                                             Enhancing IBM Tivoli SAN Manager Device Availability Alerting   3
NetView instance on the Tivoli Storage Area Network Manager server already performs a
               number of functions, displaying the SAN topology (as a NetView map) and receiving and
               forwarding SNMP traps from SAN devices to Tivoli Storage Area Network Manager to trigger
               automatic topology refreshes. This NetView instance can also receive the device FC Mgmt
               traps and use these to query the sending device and its sensors status and send more
               detailed failure alerts to the NetView event log or Tivoli Enterprise Console.

               Figure 2 shows the execution flow for the monitoring and alerting solution described in this
               paper.


                            Tivoli Storage Area
                            Network Manager
                                                  4. Execute monitor script
                  2. FC Mgmt
                                      3. Trap
                      Trap
                                         Lookup                                          Tivoli Enterprise
                                                                                         Console
                   NetView
                                 Tivoli
                                                   6. Issue Tivoli Enterprise
                                                                                         NetView
                                NetView                                                  Event Log
                                                        Console event and
                                                        new SNMP trap
                 1. FC Mgmt
                     Trap                   5. FC Mgmt MIB
                                                Queries




                               SAN Switch

               Figure 2 Overview of the execution flow

               The following steps describe the execution flow for the monitoring and alerting solution:
               1. NetView receives an FC Mgmt trap from a device that indicates a device event or change
                  in state.
               2. NetView forwards this event to Tivoli Storage Area Network Manager to trigger a topology
                  refresh.
               3. NetView looks up its definition for FC Mgmt traps. Associated with the trap is a script that
                  should be executed on receipt of the trap.
               4. The monitor and alerting script is called and executed.
               5. The script executes NetView functions to query the FC Mgmt MIB on the device issuing
                  the trap to return further details from the device.
               6. A new SNMP trap or Tivoli Enterprise Console events, or both, are issued. These are in
                  formatted text and show more detailed information.

               As shown in Figure 2, these new SNMP traps can be displayed in the NetView event log on
               the Tivoli Storage Area Network Manager server along with the Tivoli Storage Area Network
               Manager events about the availability of the SAN fabric, or on a Tivoli Enterprise Console.




4   Enhancing IBM Tivoli SAN Manager Device Availability Alerting
Configuring the solution
           The following instructions show you the steps to configure NetView to provide detailed
           alerting and monitoring using FC Mgmt MIB traps. We refer to the installation package that
           you can download with this paper, SANenvmonitor.zip, or just “the package.”


Installing the executables
           To install the SANenvmonitor.zip package, simply unzip it. It unzips to the directories
           customscripts and custombin. This paper assumes that the package is installed on the C:
           drive. Although any drive can be used, several scripts assume installation on the C drive;
           therefore, if this is not the case, these scripts will need to be edited to reflect the actual
           installation drive.

           The package includes an open source version of the Perl interpreter that comes from the
           Tivoli Framework installation CD. The executables for Perl are installed in the directory
           C:custombin.

           The path to the executables needs to be added to the Microsoft® Windows® PATH system
           environment variable. Environment variables can be changed from the Control Panel by
           selecting System Properties and clicking the Advanced tab. Figure 3 shows the addition of
           the directory C:custombin to the path.




           Figure 3 Edit the PATH environment variable

           This paper assumes that the scripts and other executables required are installed in the
           C:customscripts directory.

           To issue the event to Tivoli Enterprise Console, a copy of the Tivoli Enterprise Console
           Version 3.8 version of postemsg.exe is included with the package. This should be compatible
           with any version of Tivoli Enterprise Console. It is installed in the custom/scripts directory.


Loading the FC Mgmt MIB
           For NetView to correctly query and interpret the contents of the FC Mgmt MIB on the
           monitored devices, the MIB definitions need to be loaded into NetView.

           To load the MIB definitions:
           1. The MIB loader option is only available if the NetView advanced menus are activated. If
              the advanced menus are not already available, from the NetView Console menu, select
              Options → Advanced Menu. Stop and restart the console to activate the advanced
              menus.
           2. Then, from the NetView Console menu, select Tools → MIB → Loader SNMP V1. This
              opens the MIB Loader panel, as shown in Figure 4.




                                            Enhancing IBM Tivoli SAN Manager Device Availability Alerting   5
Figure 4 NetView MIB Loader panel

               3. Click Load. Browse to the directory where the FC Mgmt MIB was installed
                  (c:customscripts by default). Select the FC Mgmt MIB (v3_0FA.mib), and click Open to
                  load the MIB.


Triggering automatic execution
               A native capability of NetView is to execute commands on the receipt of traps, passing details
               of the received traps as variables when the command is executed. This ability is used to
               execute the monitoring and alerting script on receipt of one of the FC Mgmt traps. The trap
               definitions must be loaded into NetView for it to recognize the traps. Associated with this
               definition is the command to be executed and the variables to be passed to it. When
               configured, NetView will execute the script on receipt of an FC Mgmt MIB trap.

               Most SAN devices now support the FC Mgmt or Fibre Alliance (FA) 3.0 MIB and typically a
               copy of the MIB is supplied by the SAN device vendor. This solution assumes that the devices
               being monitored support this version of the MIB. A sample copy, v3_0FA.mib, is included in
               this package for use with the solution. To load the FC Mgmt trap definitions into NetView, the
               definitions supplied in the MIB file need to be converted into NetView addtrap commands,
               which are then executed to define the traps to NetView.

               The NetView mib2trap command is executed to create a batch file containing NetView
               addtrap commands to define the traps to NetView:
                  mib2trap c:customscriptsv3_0FA.mib c:customscriptsv3_0FA.bat

               The generated batch file (v3_0FA.bat) should then be executed to register the trap
               definitions. Note that the directory path for the addtrap commands in the created batch file
               might need to be edited to point to the directory where NetView was installed. A sample
               output when executing v3_0FA.bat is shown in Example 1.

               Example 1 Output of executing v3_0FA.bat
               C:Customscripts>v3_0fa.bat

               C:usrOVbinaddtrap -l connUnitEventTrap -g 6 -s 4 -n fcmgmt -i 1.3.6.1.3.94 -o A -c
               LOGONLY -t 0 -S 1 -f - -F "$E $G $S $# args: $*"



6   Enhancing IBM Tivoli SAN Manager Device Availability Alerting
trapd.conf file read
Trap has been added.
writing trapd.conf file...

C:usrOVbinaddtrap -l connUnitSensorStatusChange -g 6 -s 5 -n fcmgmt -i 1.3.6.1.3.94 -o
A -c LOGONLY -t 0 -S 1 -f - -F "$E $G $S $# args: $*"
trapd.conf file read
Trap has been added.
writing trapd.conf file...
…………..


After the batch file has been executed to add the trap definitions for the FC Mgmt MIB to
NetView, the trap definition must be altered in NetView to execute the monitor script when the
trap is received. This must be performed for each of the four different FC Mgmt MIB traps
supported by this solution. The connUnitSensorStateChange trap is used as an example in
the screen captions. The process for the other three traps is identical. The four traps are:
   connUnitEventTrap
   connUnitPortStatusChange
   connUnitSensorStateChange
   connUnitStatusChange

To alter the trap definition:
1. From the NetView Console menu, select Options → Trap Settings. This opens the Trap
   Settings panel, as shown in Figure 5.




Figure 5 NetView Trap Settings panel




                                Enhancing IBM Tivoli SAN Manager Device Availability Alerting   7
2. In the top half of the panel (labeled Select an enterprise), highlight the fcmgmt enterprise.
                  On the bottom half of the panel (labeled Select a trap), select the
                  connUnitSensorStatusChange trap. Select Properties to open the Trap Properties
                  panel, as shown in Figure 6.




               Figure 6 NetView Trap Properties for the connUnitSensorStatusChange trap

               3. In the Run this command when the trap is received field, enter the directory and name of
                  the script, followed by $A $S $-1 $2 “$4”, which passes the required variables from the
                  original trap. $A is the source of the trap, $S is the trap number, and the other variables
                  are data presented by the device in the traps. The full string will be:
                      c:customscriptsfcmgmttraps.bat $A $S $-1 $2 “$4”
               4. In the Run as field, select Hidden Application. This executes the script as a hidden
                  application each time the trap is received. On some NetView instances, it has been found
                  that the script does not execute when set to Hidden Application. If this is the case, the
                  alternative option Console Application can be used. The Display the Trap Category as
                  field is set to Only Log Event, so on receipt, the original unformatted FC Mgmt event is
                  not displayed in the NetView event log, only the new formatted trap. Click OK.


Enabling devices to be monitored
               Devices to be monitored must be configured to send FC Mgmt traps to NetView. Where the
               monitor is implemented on the NetView instance used by Tivoli Storage Area Network
               Manager, SAN switches will have already been configured to send their FC Mgmt events to
               this instance of NetView, and further configuration is not required. Any other devices to be
               monitored in this fashion must also be configured to route their FC Mgmt traps to NetView. In
               addition to switches, this can include fibre-to-SCSI gateways, storage arrays, and other SAN
               attached devices that also support the FC Mgmt MIB.

               Configuration of trap forwarding on devices usually also includes the ability to set the devices’
               SNMP community name. All devices must be configured to use the same SNMP community
               name with read permissions to the FC Mgmt MIB variables. Make a note of this community
               name, because it is used later in the configuration.




8   Enhancing IBM Tivoli SAN Manager Device Availability Alerting
Configuring the monitor
           A number of variables in the fcmgmttraps.pl script need editing to reflect local values. These
           include:
              $CommunityName: The SNMP community name used for read access to the FC Mgmt
              MIB variables on the monitored devices.
              $NV_PATH: NetView installation directory.
              $TEC_PATH: Installation path of the monitor script and Tivoli Enterprise Console
              configuration file.

           By default, the script sends both an SNMP trap and Tivoli Enterprise Console event.
           Depending on which event is needed, the script needs editing to specify whether or not to
           issue the SNMP trap or Tivoli Enterprise Console event.



Displaying and formatting the events
           The new events issued by this solution map directly to the corresponding FC Mgmt MIB traps:
              SAN Event: connUnitEventTrap
              SAN Port: connUnitPortStatusChange
              SAN Environment: connUnitSensorStateChange
              SAN State: connUnitStatusChange

           Now, we show you how to configure NetView and Tivoli Enterprise Console to display these
           new events in the NetView event log and Tivoli Enterprise Console in formatted and readable
           text.


Displaying the event in NetView
           To enable the new SNMP trap to be displayed in the NetView event log on the Tivoli Storage
           Area Network Manager server, a new trap definition is used to display and format the event.
           The definitions for these new traps are contained in the file fcmgmttrapdefs.bat in the scripts
           directory. The new trap definitions are added to the traps already defined for NetView, using
           high trap numbers to avoid conflict with existing trap definitions.
           Executing the batch file will define the new traps to NetView so that they can be properly
           displayed and formatted. Example 2 shows a sample execution of fcmgmttrapdefs.bat.

           Example 2 Sample execution output of fcmgmttrapdefs.bat
           C:customscripts>fcmgmttrapdefs

           C:>C:usrOVbinaddtrap -l SAN_Environment -g 6 -s 99000001 -n NetView -i
           1.3.6.1.4.1.2.6.3 -o A -c "Status Events" -t 0 -S 1 -f - -F $1
           trapd.conf file read
           Trap has been added.
           writing trapd.conf file...

           C:>C:usrOVbinaddtrap -l SAN_Event -g 6 -s 99000004 -n NetView -i 1.3.6.1.4.1.2.6.3 -o
           A -c "Status Events" -t 0 -S 1 -f - -F $1
           trapd.conf file read
           Trap has been added.
           writing trapd.conf file...
           ………………………………..




                                           Enhancing IBM Tivoli SAN Manager Device Availability Alerting   9
To display the new trap definitions and verify that they have been loaded correctly:
               1. From the NetView Console menu, select Options → Trap Settings. This opens the Trap
                  Settings panel, as shown in Figure 7.




               Figure 7 Trap Settings panel for NetView enterprise

               2. In the top half of the panel (labeled Select an Enterprise), highlight the NetView entry. This
                  opens the list of defined NetView traps. Scroll down to the SAN_Environment trap and
                  click Properties to display the details, as shown in Figure 8.




               Figure 8 Trap Properties panel




10   Enhancing IBM Tivoli SAN Manager Device Availability Alerting
Displaying the event on Tivoli Enterprise Console
            To sent the event to a Tivoli Enterprise Console, the tecad_nt.conf file in the scripts directory
            needs to be modified to send events to the correct Tivoli Enterprise Console. The statements
            shown in Example 3 need to be changed to point to the Tivoli Enterprise Console server and
            port in your environment.

            Example 3 Statements to modify in the tecad_nt.conf file
            ServerLocation=sienna
            ServerPort=5529


            To enable the event to be formatted and displayed on the Tivoli Enterprise Console server,
            the event class definitions for the events in the san.baroc file found in the scripts directory
            need to be loaded into the Tivoli Enterprise Console database. Details about how to load a
            baroc file can be found in Chapter 10, “Tivoli SAN Manager and Tivoli Enterprise Console,” of
            the IBM Redbook, IBM Tivoli Storage Area Network Manager: A Practical Introduction,
            SG24-6848.


Tivoli Enterprise Console event information
            The information available in the FC Mgmt MIB about events, device availability, and status is
            fully documented in the v3_0FA.mib file contained in the package. The following fields are
            passed as part of the Tivoli Enterprise Console events:
               SAN Environment
               – UnitSensorName: Power Supply, Fan, Temperature Sensor
               – UnitSensorStatus: OK, Failed, Warning
               – UnitSensorMSG: More detailed information about sensor state
               SAN Port
               – Port State: Online, Offline, Bypassed
               – Port Status: OK, Failed, Warning, Initializing, Bypassed, Not Participating
               – PortHWStatus: Active, Failed, NoMedia, TxFault
               SAN Event
               – EventDesc: Description of the event
               – EventSeverity: Severity
               – EventRTime: Time of the event at the device
               – EventType: Type of event
               – EventIndex: Index to event in device event table
               SAN State
               – UnitState: Online, Offline
               – UnitStatus: OK, Warning, Failed


Testing the final result
            The original FC Mgmt traps issued by the devices are not displayed in the NetView event log,
            because by default, they are “displayed” by NetView as Only Log Events and not written to
            the event log. To test the solution, this can be changed in the Trap Properties panel to Status
            Events so that they are displayed in the event log on receipt. It then becomes an easy job to
            check that when an original FC Mgmt trap is received the corresponding SAN trap generated
            by the script is also displayed. After it has been verified that the new traps are being correctly
            issued and displayed, the display category can be changed back to Only Log Event.

            If the script does not execute, and the new events issued when the execution mode of the
            script in the trap properties is set to Hidden Application, the alternative option, Console
            Application, can be used.


                                            Enhancing IBM Tivoli SAN Manager Device Availability Alerting   11
Figure 9 shows examples of all the events shown on a Tivoli Enterprise Console and also in
                 the NetView event log on the Tivoli Storage Area Network Manager.




Figure 9 Events on Tivoli Enterprise Console and in the NetView event log

                 If the events are not displayed as expected, the scripts santest.bat and santest.pl in the
                 scripts directory can be used in place of the fcmgmttraps scripts to test that NetView is calling
                 the scripts correctly and is passing the expected variables. If the events are displayed in
                 NetView and on Tivoli Enterprise Console, but do not contain the expected information, the
                 fcmgmttrap.bat file can be executed from a Windows command prompt with the appropriate
                 variables. Samples of the expected variable input can be found in the file testinput.txt. Some
                 of the variables need to be customized to local values for the scripts to retrieve information
                 correctly from the switches and display it in the formatted events. The information displayed
                 by the NetView trap issued by the santest scripts can be used for this purpose.

                 QLogic SAN switches
                 When testing the solution, we found that the traps from Brocade switches and InRange
                 directors fully follow the trap definitions laid out in the FC Mgmt MIB 3.0 definitions and will
                 trigger execution of the monitor script. However, QLogic switches, such as the SANBox2-16
                 (also rebadged by InRange), issue FC Mgmt traps under a different “enterprise,” and a
                 modified set of trap definitions had to be loaded to trigger execution of the script. This is
                 shown in Figure 10.




12    Enhancing IBM Tivoli SAN Manager Device Availability Alerting
Figure 10 NetView Event Details for FC Mgmt trap from QLogic SANBox2-16switch

The figure shows the Event Details in the NetView event log of a trap received from a QLogic
SANBox2-16. Double-click the event in the log to get this view. It is shown unformatted
because NetView does not recognize the event. The difference was found in the Enterprise
number used by QLogic, which was 1.3.6.1.4.824.1.6. To create the correct set of trap
definitions, the addtrap commands generated by the running the mib2trap command against
the v3_0FA.mib file had to be edited to specify this new enterprise number before being
executed. A new enterprise name of qlogicfcmgmt was used. All references in the batch file
generated by the mib2trap command to fcmgmt were changed to qlogicfcmgmt, and the
enterprise number was changed from 1.3.6.1.3.94 to 1.3.6.1.4.824.1.6 to reflect the
enterprise number under which the traps are issued. Example 4 shows the execution output
of the edited batch file.

Example 4 Sample output of v3_0FA.bat edited to recognize QLogic events
C:Customscripts>v3_0fa.bat

C:Customscripts>C:usrOVbinaddtrap -l connUnitStatusChange -g 6 -s 1 -n qlogicfcmgmt
-i 1.3.6.1.4.824.1.6 -o A -c LOGONLY -t 0 -S 1 -f - -F "$E $G $S $# args: $*"
………………


Setup and usage is the same as previously described.

McData directors and switches
Similarly, McData for their directors and switches use a variation of the standard FC Mgmt
MIB. In this case, both the MIB and the traps use a different enterprise to that used by the
“standard” FC Mgmt MIB. Figure 11 shows the traps generated with the default configuration.




                               Enhancing IBM Tivoli SAN Manager Device Availability Alerting   13
Figure 11 McData FC Mgmt trap with no NetView definition loaded

               This solution was tested with a McData Sphereon 4500. The FC Mgmt MIB definition file with
               a revision number of 200105080000Z was used. This MIB file was in SNMP v2 format, and a
               copy can be found in the custom/scripts directory as fcmgmt.mib. This version of the FC
               Mgmt MIB has to be loaded into NetView using the loadmibv2 program, which is in the
               usr/ov/bin NetView installation directory. Because the MIB file is in SNMP v2 format, the
               mib2trap command cannot be used to create the addtrap commands to define the FC Mgmt
               traps to NetView. A batch file, fcmgmttrapdefsmcdata.bat, is included in the scripts directory
               containing the correct addtrap commands.

               After the fcmgmtmcdata.bat batch file has been executed, and the traps have been defined,
               the trap properties need to be modified similarly to the QLogic devices, as described in
               “Triggering automatic execution” on page 6. Two McData specific scripts are included,
               fcmgmttrapsmcdata.pl and fcmgmttrapsmcdata.bat, which are specific to the McData
               implementation of the FC Mgmt MIB. As a result, the script to be executed on receipt of an FC
               Mgmt trap by NetView is fmgmttrapsmcdata.bat.

               Because McData passes slightly different information in the traps, the details of variables
               passed on each script are slightly different. For connUnitEventTrap,
               connUnitPortStatusChange, and connUnitSensorStateChange, it is similar to as before:
                  c:customscriptsfcmgmttrapsmcdata.bat $A $S $-1 $2 “$4”

               For connUnitEventTrap, it is:
                  c:customscriptsfcmgmttrapsmcdata.bat $A $S $-2 $2 “$4”




14   Enhancing IBM Tivoli SAN Manager Device Availability Alerting
Summary
                 This paper has shown how it is possible to enhance the Tivoli Storage Area Network Manager
                 SAN management solution with real-time device health and availability alerting. This is an
                 important component of an end-to-end monitoring solution for storage availability
                 management. It enables failures which are not yet impacting application availability to be
                 addressed before they can have an impact. Sending these events to a central point and
                 displaying them on an event console such as the Tivoli Enterprise Console provides a single
                 point for administrators to view storage events relating to the entire storage infrastructure.
                 More significantly, this single view allows correlation between events to be performed,
                 enabling more rapid identification of the root cause of failures, as well as reducing
                 administrative effort in monitoring a heterogeneous multivendor storage environment.
                 Figure 12 shows Tivoli Storage Area Network Manager events and the formatted FC Mgmt
                 events as created by this solution displayed on a Tivoli Enterprise Console in conjunction with
                 events from other applications.




Figure 12 Tivoli Storage Area Network Manager and formatted FC Mgmt events on Tivoli Enterprise Console




                                                Enhancing IBM Tivoli SAN Manager Device Availability Alerting   15
The team that wrote this Redpaper
               Steve Strutt is a Certified IT Specialist in the U.K., working in Technical Sales Support. He
               holds a bachelor's degree in Electronic Engineering and has more than 18 years of
               experience in IBM storage and storage management tools from z/OS to open systems
               storage. His areas of expertise include enterprise storage architecture, tape storage systems,
               Tivoli Storage Manager, Storage Area Networking, and Storage Resource Management and
               systems management.

               Thanks to the following people for their invaluable contributions to this and the previous
               edition of this Redpaper:

               Charlotte Brooks
               Emma Jacobs
               International Technical Support Organization, San Jose Center

               Elizabeth Barnes
               International Technical Support Organization, Austin Center

               Richard Hine
               Tivoli Systems, U.K.




16   Enhancing IBM Tivoli SAN Manager Device Availability Alerting
Notices

This information was developed for products and services offered in the U.S.A.

IBM may not offer the products, services, or features discussed in this document in other countries. Consult
your local IBM representative for information on the products and services currently available in your area.
Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM
product, program, or service may be used. Any functionally equivalent product, program, or service that does
not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to
evaluate and verify the operation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents. You can send license inquiries, in
writing, to:
IBM Director of Licensing, IBM Corporation, North Castle Drive Armonk, NY 10504-1785 U.S.A.

The following paragraph does not apply to the United Kingdom or any other country where such
provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION
PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of
express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made
to the information herein; these changes will be incorporated in new editions of the publication. IBM may make
improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time
without notice.

Any references in this information to non-IBM Web sites are provided for convenience only and do not in any
manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the
materials for this IBM product and use of those Web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believes appropriate without
incurring any obligation to you.

Information concerning non-IBM products was obtained from the suppliers of those products, their published
announcements or other publicly available sources. IBM has not tested those products and cannot confirm the
accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the
capabilities of non-IBM products should be addressed to the suppliers of those products.

This information contains examples of data and reports used in daily business operations. To illustrate them
as completely as possible, the examples include the names of individuals, companies, brands, and products.
All of these names are fictitious and any similarity to the names and addresses used by an actual business
enterprise is entirely coincidental.

COPYRIGHT LICENSE:
This information contains sample application programs in source language, which illustrates programming
techniques on various operating platforms. You may copy, modify, and distribute these sample programs in
any form without payment to IBM, for the purposes of developing, using, marketing or distributing application
programs conforming to the application programming interface for the operating platform for which the sample
programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore,
cannot guarantee or imply reliability, serviceability, or function of these programs. You may copy, modify, and
distribute these sample programs in any form without payment to IBM for the purposes of developing, using,
marketing, or distributing application programs conforming to IBM's application programming interfaces.




© Copyright IBM Corp. 2004. All rights reserved.                                                               17
Send us your comments in one of the following ways:
  Use the online Contact us review redbook form found at:
  ibm.com/redbooks                                                                                       ®
  Send your comments in an Internet note to:
  redbook@us.ibm.com
  Mail your comments to:
  IBM Corporation, International Technical Support Organization
  Dept. QXXE Building 80-E2
  650 Harry Road
  San Jose, California 95120-6099 U.S.A.



Trademarks
The following terms are trademarks of the International Business Machines Corporation in the United States,
other countries, or both:

  IBM®                                 Redbooks™                          Tivoli Enterprise™
  ibm.com®                             Redbooks(logo)     ™               Tivoli Enterprise Console®
  NetView®                             Tivoli®                            TotalStorage®

The following terms are trademarks of other companies:

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the
United States, other countries, or both.

Other company, product, and service names may be trademarks or service marks of others.




18    Enhancing IBM Tivoli SAN Manager Device Availability Alerting

Mais conteúdo relacionado

Destaque

IBM MobileFirst Platform v7.0 POT App Mgmt Lab v1.1
IBM MobileFirst Platform  v7.0 POT App Mgmt Lab v1.1IBM MobileFirst Platform  v7.0 POT App Mgmt Lab v1.1
IBM MobileFirst Platform v7.0 POT App Mgmt Lab v1.1Banking at Ho Chi Minh city
 
SYMANTEC ENDPOINT PROTECTION Advanced Monitoring and Reporting
SYMANTEC ENDPOINT PROTECTION Advanced Monitoring and ReportingSYMANTEC ENDPOINT PROTECTION Advanced Monitoring and Reporting
SYMANTEC ENDPOINT PROTECTION Advanced Monitoring and ReportingDsunte Wilson
 
IBM MobileFirst Platform v7.0 POT Offers Lab v1.0
IBM MobileFirst Platform v7.0 POT Offers Lab v1.0IBM MobileFirst Platform v7.0 POT Offers Lab v1.0
IBM MobileFirst Platform v7.0 POT Offers Lab v1.0Banking at Ho Chi Minh city
 
SYMANTEC ENDPOINT PROTECTION Administration Introduction
SYMANTEC ENDPOINT PROTECTION Administration IntroductionSYMANTEC ENDPOINT PROTECTION Administration Introduction
SYMANTEC ENDPOINT PROTECTION Administration IntroductionDsunte Wilson
 

Destaque (7)

IBM MobileFirst Platform v7.0 POT App Mgmt Lab v1.1
IBM MobileFirst Platform  v7.0 POT App Mgmt Lab v1.1IBM MobileFirst Platform  v7.0 POT App Mgmt Lab v1.1
IBM MobileFirst Platform v7.0 POT App Mgmt Lab v1.1
 
IBM MobileFirst Platform v7.0 pot intro v0.1
IBM MobileFirst Platform v7.0 pot intro v0.1IBM MobileFirst Platform v7.0 pot intro v0.1
IBM MobileFirst Platform v7.0 pot intro v0.1
 
SYMANTEC ENDPOINT PROTECTION Advanced Monitoring and Reporting
SYMANTEC ENDPOINT PROTECTION Advanced Monitoring and ReportingSYMANTEC ENDPOINT PROTECTION Advanced Monitoring and Reporting
SYMANTEC ENDPOINT PROTECTION Advanced Monitoring and Reporting
 
IBM MobileFirst Platform v7.0 POT Offers Lab v1.0
IBM MobileFirst Platform v7.0 POT Offers Lab v1.0IBM MobileFirst Platform v7.0 POT Offers Lab v1.0
IBM MobileFirst Platform v7.0 POT Offers Lab v1.0
 
SYMANTEC ENDPOINT PROTECTION Administration Introduction
SYMANTEC ENDPOINT PROTECTION Administration IntroductionSYMANTEC ENDPOINT PROTECTION Administration Introduction
SYMANTEC ENDPOINT PROTECTION Administration Introduction
 
IBM MobileFirst Foundation Version Flyer v1.0
IBM MobileFirst Foundation Version Flyer v1.0IBM MobileFirst Foundation Version Flyer v1.0
IBM MobileFirst Foundation Version Flyer v1.0
 
IBM MobileFirst Platform v7 Tech Overview
IBM MobileFirst Platform v7 Tech OverviewIBM MobileFirst Platform v7 Tech Overview
IBM MobileFirst Platform v7 Tech Overview
 

Semelhante a Enhancing ibm tivoli san manager device availability alerting redp3821

Cw13 journy to the cloud by mohamed el mofty
Cw13 journy to the cloud by mohamed el moftyCw13 journy to the cloud by mohamed el mofty
Cw13 journy to the cloud by mohamed el moftyTheInevitableCloud
 
IBM Tivoli Storage Productivit Center overview and update
IBM Tivoli Storage Productivit Center overview and updateIBM Tivoli Storage Productivit Center overview and update
IBM Tivoli Storage Productivit Center overview and updateTony Pearson
 
An Introduction to OpenSAF 5.17.2011
An Introduction to OpenSAF 5.17.2011An Introduction to OpenSAF 5.17.2011
An Introduction to OpenSAF 5.17.2011OpenSAF Foundation
 
OpenSAF Symposium - Intro to OpenSAF_9.13.11
OpenSAF Symposium - Intro to OpenSAF_9.13.11OpenSAF Symposium - Intro to OpenSAF_9.13.11
OpenSAF Symposium - Intro to OpenSAF_9.13.11OpenSAF Foundation
 
Ibm san volume controller and ibm tivoli storage flash copy manager redp4653
Ibm san volume controller and ibm tivoli storage flash copy manager redp4653Ibm san volume controller and ibm tivoli storage flash copy manager redp4653
Ibm san volume controller and ibm tivoli storage flash copy manager redp4653Banking at Ho Chi Minh city
 
Emc san Online Training in Hyderabad
Emc san Online Training in HyderabadEmc san Online Training in Hyderabad
Emc san Online Training in HyderabadUgs8008
 
EMC SAN Online Training in India
EMC SAN Online Training in IndiaEMC SAN Online Training in India
EMC SAN Online Training in IndiaUgs8008
 
Mpls conference 2016-data center virtualisation-11-march
Mpls conference 2016-data center virtualisation-11-marchMpls conference 2016-data center virtualisation-11-march
Mpls conference 2016-data center virtualisation-11-marchAricent
 
eMagic : A Complete Datacenter Management Suite
eMagic : A Complete Datacenter Management SuiteeMagic : A Complete Datacenter Management Suite
eMagic : A Complete Datacenter Management SuiteRaj Gire
 
Obn211111 i manager n2000 bms introduction r011 issue 1.0
Obn211111 i manager n2000 bms introduction r011 issue 1.0Obn211111 i manager n2000 bms introduction r011 issue 1.0
Obn211111 i manager n2000 bms introduction r011 issue 1.0Vìctor Isaac Herrera Pérez
 
Summit 16: Open-O Mini-Summit - VF Event Streaming Project Proposal
Summit 16: Open-O Mini-Summit - VF Event Streaming Project ProposalSummit 16: Open-O Mini-Summit - VF Event Streaming Project Proposal
Summit 16: Open-O Mini-Summit - VF Event Streaming Project ProposalOPNFV
 
Bringing Mainframe Security Information Into Your Splunk Security Operations ...
Bringing Mainframe Security Information Into Your Splunk Security Operations ...Bringing Mainframe Security Information Into Your Splunk Security Operations ...
Bringing Mainframe Security Information Into Your Splunk Security Operations ...Precisely
 
Monitoring Management Overview
Monitoring Management OverviewMonitoring Management Overview
Monitoring Management OverviewSebastian Osterc
 
Highilights from Rod Randall (SIRIS/Stratus) LTE Asia
Highilights from Rod Randall (SIRIS/Stratus) LTE AsiaHighilights from Rod Randall (SIRIS/Stratus) LTE Asia
Highilights from Rod Randall (SIRIS/Stratus) LTE AsiaAlan Quayle
 
Aqualogic monitoring system datasheet
Aqualogic monitoring system datasheetAqualogic monitoring system datasheet
Aqualogic monitoring system datasheetChenna Keshav
 
Aqualogic monitoring system datasheet
Aqualogic monitoring system datasheetAqualogic monitoring system datasheet
Aqualogic monitoring system datasheetChenna Keshavulu
 
NA Element May 2014 Webinar_Widescreen Format
NA Element May 2014 Webinar_Widescreen FormatNA Element May 2014 Webinar_Widescreen Format
NA Element May 2014 Webinar_Widescreen FormatMichael Christofferson
 
VMware Developer-Ready Transformation
VMware Developer-Ready TransformationVMware Developer-Ready Transformation
VMware Developer-Ready TransformationVMware Tanzu
 
Present and desired network management to cope with the expected expansion, n...
Present and desired network management to cope with the expected expansion, n...Present and desired network management to cope with the expected expansion, n...
Present and desired network management to cope with the expected expansion, n...Alexander Decker
 
How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network
How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network
How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network SolarWinds
 

Semelhante a Enhancing ibm tivoli san manager device availability alerting redp3821 (20)

Cw13 journy to the cloud by mohamed el mofty
Cw13 journy to the cloud by mohamed el moftyCw13 journy to the cloud by mohamed el mofty
Cw13 journy to the cloud by mohamed el mofty
 
IBM Tivoli Storage Productivit Center overview and update
IBM Tivoli Storage Productivit Center overview and updateIBM Tivoli Storage Productivit Center overview and update
IBM Tivoli Storage Productivit Center overview and update
 
An Introduction to OpenSAF 5.17.2011
An Introduction to OpenSAF 5.17.2011An Introduction to OpenSAF 5.17.2011
An Introduction to OpenSAF 5.17.2011
 
OpenSAF Symposium - Intro to OpenSAF_9.13.11
OpenSAF Symposium - Intro to OpenSAF_9.13.11OpenSAF Symposium - Intro to OpenSAF_9.13.11
OpenSAF Symposium - Intro to OpenSAF_9.13.11
 
Ibm san volume controller and ibm tivoli storage flash copy manager redp4653
Ibm san volume controller and ibm tivoli storage flash copy manager redp4653Ibm san volume controller and ibm tivoli storage flash copy manager redp4653
Ibm san volume controller and ibm tivoli storage flash copy manager redp4653
 
Emc san Online Training in Hyderabad
Emc san Online Training in HyderabadEmc san Online Training in Hyderabad
Emc san Online Training in Hyderabad
 
EMC SAN Online Training in India
EMC SAN Online Training in IndiaEMC SAN Online Training in India
EMC SAN Online Training in India
 
Mpls conference 2016-data center virtualisation-11-march
Mpls conference 2016-data center virtualisation-11-marchMpls conference 2016-data center virtualisation-11-march
Mpls conference 2016-data center virtualisation-11-march
 
eMagic : A Complete Datacenter Management Suite
eMagic : A Complete Datacenter Management SuiteeMagic : A Complete Datacenter Management Suite
eMagic : A Complete Datacenter Management Suite
 
Obn211111 i manager n2000 bms introduction r011 issue 1.0
Obn211111 i manager n2000 bms introduction r011 issue 1.0Obn211111 i manager n2000 bms introduction r011 issue 1.0
Obn211111 i manager n2000 bms introduction r011 issue 1.0
 
Summit 16: Open-O Mini-Summit - VF Event Streaming Project Proposal
Summit 16: Open-O Mini-Summit - VF Event Streaming Project ProposalSummit 16: Open-O Mini-Summit - VF Event Streaming Project Proposal
Summit 16: Open-O Mini-Summit - VF Event Streaming Project Proposal
 
Bringing Mainframe Security Information Into Your Splunk Security Operations ...
Bringing Mainframe Security Information Into Your Splunk Security Operations ...Bringing Mainframe Security Information Into Your Splunk Security Operations ...
Bringing Mainframe Security Information Into Your Splunk Security Operations ...
 
Monitoring Management Overview
Monitoring Management OverviewMonitoring Management Overview
Monitoring Management Overview
 
Highilights from Rod Randall (SIRIS/Stratus) LTE Asia
Highilights from Rod Randall (SIRIS/Stratus) LTE AsiaHighilights from Rod Randall (SIRIS/Stratus) LTE Asia
Highilights from Rod Randall (SIRIS/Stratus) LTE Asia
 
Aqualogic monitoring system datasheet
Aqualogic monitoring system datasheetAqualogic monitoring system datasheet
Aqualogic monitoring system datasheet
 
Aqualogic monitoring system datasheet
Aqualogic monitoring system datasheetAqualogic monitoring system datasheet
Aqualogic monitoring system datasheet
 
NA Element May 2014 Webinar_Widescreen Format
NA Element May 2014 Webinar_Widescreen FormatNA Element May 2014 Webinar_Widescreen Format
NA Element May 2014 Webinar_Widescreen Format
 
VMware Developer-Ready Transformation
VMware Developer-Ready TransformationVMware Developer-Ready Transformation
VMware Developer-Ready Transformation
 
Present and desired network management to cope with the expected expansion, n...
Present and desired network management to cope with the expected expansion, n...Present and desired network management to cope with the expected expansion, n...
Present and desired network management to cope with the expected expansion, n...
 
How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network
How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network
How-To: Linux Performance Monitoring & Management for your Multi-Vendor Network
 

Mais de Banking at Ho Chi Minh city

IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1
IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1
IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1Banking at Ho Chi Minh city
 
Tme 10 cookbook for aix systems management and networking sg244867
Tme 10 cookbook for aix systems management and networking sg244867Tme 10 cookbook for aix systems management and networking sg244867
Tme 10 cookbook for aix systems management and networking sg244867Banking at Ho Chi Minh city
 
Tivoli data warehouse version 1.3 planning and implementation sg246343
Tivoli data warehouse version 1.3 planning and implementation sg246343Tivoli data warehouse version 1.3 planning and implementation sg246343
Tivoli data warehouse version 1.3 planning and implementation sg246343Banking at Ho Chi Minh city
 
Tivoli data warehouse 1.2 and business objects redp9116
Tivoli data warehouse 1.2 and business objects redp9116Tivoli data warehouse 1.2 and business objects redp9116
Tivoli data warehouse 1.2 and business objects redp9116Banking at Ho Chi Minh city
 
Tivoli business systems manager v2.1 end to-end business impact management sg...
Tivoli business systems manager v2.1 end to-end business impact management sg...Tivoli business systems manager v2.1 end to-end business impact management sg...
Tivoli business systems manager v2.1 end to-end business impact management sg...Banking at Ho Chi Minh city
 
Tape automation with ibm e server xseries servers redp0415
Tape automation with ibm e server xseries servers redp0415Tape automation with ibm e server xseries servers redp0415
Tape automation with ibm e server xseries servers redp0415Banking at Ho Chi Minh city
 
Tivoli storage productivity center v4.2 release guide sg247894
Tivoli storage productivity center v4.2 release guide sg247894Tivoli storage productivity center v4.2 release guide sg247894
Tivoli storage productivity center v4.2 release guide sg247894Banking at Ho Chi Minh city
 
Synchronizing data with ibm tivoli directory integrator 6.1 redp4317
Synchronizing data with ibm tivoli directory integrator 6.1 redp4317Synchronizing data with ibm tivoli directory integrator 6.1 redp4317
Synchronizing data with ibm tivoli directory integrator 6.1 redp4317Banking at Ho Chi Minh city
 
Storage migration and consolidation with ibm total storage products redp3888
Storage migration and consolidation with ibm total storage products redp3888Storage migration and consolidation with ibm total storage products redp3888
Storage migration and consolidation with ibm total storage products redp3888Banking at Ho Chi Minh city
 
Solution deployment guide for ibm tivoli composite application manager for we...
Solution deployment guide for ibm tivoli composite application manager for we...Solution deployment guide for ibm tivoli composite application manager for we...
Solution deployment guide for ibm tivoli composite application manager for we...Banking at Ho Chi Minh city
 
Slr to tivoli performance reporter for os 390 migration cookbook sg245128
Slr to tivoli performance reporter for os 390 migration cookbook sg245128Slr to tivoli performance reporter for os 390 migration cookbook sg245128
Slr to tivoli performance reporter for os 390 migration cookbook sg245128Banking at Ho Chi Minh city
 
Setup and configuration for ibm tivoli access manager for enterprise single s...
Setup and configuration for ibm tivoli access manager for enterprise single s...Setup and configuration for ibm tivoli access manager for enterprise single s...
Setup and configuration for ibm tivoli access manager for enterprise single s...Banking at Ho Chi Minh city
 
Windows nt backup and recovery with adsm sg242231
Windows nt backup and recovery with adsm sg242231Windows nt backup and recovery with adsm sg242231
Windows nt backup and recovery with adsm sg242231Banking at Ho Chi Minh city
 
Tivoli management services warehouse and reporting sg247290
Tivoli management services warehouse and reporting sg247290Tivoli management services warehouse and reporting sg247290
Tivoli management services warehouse and reporting sg247290Banking at Ho Chi Minh city
 
Service level management using ibm tivoli service level advisor and tivoli bu...
Service level management using ibm tivoli service level advisor and tivoli bu...Service level management using ibm tivoli service level advisor and tivoli bu...
Service level management using ibm tivoli service level advisor and tivoli bu...Banking at Ho Chi Minh city
 

Mais de Banking at Ho Chi Minh city (20)

Postgresql v15.1
Postgresql v15.1Postgresql v15.1
Postgresql v15.1
 
Postgresql v14.6 Document Guide
Postgresql v14.6 Document GuidePostgresql v14.6 Document Guide
Postgresql v14.6 Document Guide
 
IBM MobileFirst Platform v7.0 Pot Intro v0.1
IBM MobileFirst Platform v7.0 Pot Intro v0.1IBM MobileFirst Platform v7.0 Pot Intro v0.1
IBM MobileFirst Platform v7.0 Pot Intro v0.1
 
IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1
IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1
IBM MobileFirst Platform 7.0 POT InApp Feedback V0.1
 
Tme 10 cookbook for aix systems management and networking sg244867
Tme 10 cookbook for aix systems management and networking sg244867Tme 10 cookbook for aix systems management and networking sg244867
Tme 10 cookbook for aix systems management and networking sg244867
 
Tivoli firewall magic redp0227
Tivoli firewall magic redp0227Tivoli firewall magic redp0227
Tivoli firewall magic redp0227
 
Tivoli data warehouse version 1.3 planning and implementation sg246343
Tivoli data warehouse version 1.3 planning and implementation sg246343Tivoli data warehouse version 1.3 planning and implementation sg246343
Tivoli data warehouse version 1.3 planning and implementation sg246343
 
Tivoli data warehouse 1.2 and business objects redp9116
Tivoli data warehouse 1.2 and business objects redp9116Tivoli data warehouse 1.2 and business objects redp9116
Tivoli data warehouse 1.2 and business objects redp9116
 
Tivoli business systems manager v2.1 end to-end business impact management sg...
Tivoli business systems manager v2.1 end to-end business impact management sg...Tivoli business systems manager v2.1 end to-end business impact management sg...
Tivoli business systems manager v2.1 end to-end business impact management sg...
 
Tec implementation examples sg245216
Tec implementation examples sg245216Tec implementation examples sg245216
Tec implementation examples sg245216
 
Tape automation with ibm e server xseries servers redp0415
Tape automation with ibm e server xseries servers redp0415Tape automation with ibm e server xseries servers redp0415
Tape automation with ibm e server xseries servers redp0415
 
Tivoli storage productivity center v4.2 release guide sg247894
Tivoli storage productivity center v4.2 release guide sg247894Tivoli storage productivity center v4.2 release guide sg247894
Tivoli storage productivity center v4.2 release guide sg247894
 
Synchronizing data with ibm tivoli directory integrator 6.1 redp4317
Synchronizing data with ibm tivoli directory integrator 6.1 redp4317Synchronizing data with ibm tivoli directory integrator 6.1 redp4317
Synchronizing data with ibm tivoli directory integrator 6.1 redp4317
 
Storage migration and consolidation with ibm total storage products redp3888
Storage migration and consolidation with ibm total storage products redp3888Storage migration and consolidation with ibm total storage products redp3888
Storage migration and consolidation with ibm total storage products redp3888
 
Solution deployment guide for ibm tivoli composite application manager for we...
Solution deployment guide for ibm tivoli composite application manager for we...Solution deployment guide for ibm tivoli composite application manager for we...
Solution deployment guide for ibm tivoli composite application manager for we...
 
Slr to tivoli performance reporter for os 390 migration cookbook sg245128
Slr to tivoli performance reporter for os 390 migration cookbook sg245128Slr to tivoli performance reporter for os 390 migration cookbook sg245128
Slr to tivoli performance reporter for os 390 migration cookbook sg245128
 
Setup and configuration for ibm tivoli access manager for enterprise single s...
Setup and configuration for ibm tivoli access manager for enterprise single s...Setup and configuration for ibm tivoli access manager for enterprise single s...
Setup and configuration for ibm tivoli access manager for enterprise single s...
 
Windows nt backup and recovery with adsm sg242231
Windows nt backup and recovery with adsm sg242231Windows nt backup and recovery with adsm sg242231
Windows nt backup and recovery with adsm sg242231
 
Tivoli management services warehouse and reporting sg247290
Tivoli management services warehouse and reporting sg247290Tivoli management services warehouse and reporting sg247290
Tivoli management services warehouse and reporting sg247290
 
Service level management using ibm tivoli service level advisor and tivoli bu...
Service level management using ibm tivoli service level advisor and tivoli bu...Service level management using ibm tivoli service level advisor and tivoli bu...
Service level management using ibm tivoli service level advisor and tivoli bu...
 

Último

Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfAlex Barbosa Coqueiro
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024Stephanie Beckett
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
The Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsThe Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsPixlogix Infotech
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Enterprise Knowledge
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 
Search Engine Optimization SEO PDF for 2024.pdf
Search Engine Optimization SEO PDF for 2024.pdfSearch Engine Optimization SEO PDF for 2024.pdf
Search Engine Optimization SEO PDF for 2024.pdfRankYa
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr BaganFwdays
 
Take control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteTake control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteDianaGray10
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningLars Bell
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxNavinnSomaal
 
SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024Lorenzo Miniero
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clashcharlottematthew16
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsSergiu Bodiu
 
Story boards and shot lists for my a level piece
Story boards and shot lists for my a level pieceStory boards and shot lists for my a level piece
Story boards and shot lists for my a level piececharlottematthew16
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLScyllaDB
 
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostLeverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostZilliz
 

Último (20)

Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdf
 
What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024What's New in Teams Calling, Meetings and Devices March 2024
What's New in Teams Calling, Meetings and Devices March 2024
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
The Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and ConsThe Ultimate Guide to Choosing WordPress Pros and Cons
The Ultimate Guide to Choosing WordPress Pros and Cons
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 
Search Engine Optimization SEO PDF for 2024.pdf
Search Engine Optimization SEO PDF for 2024.pdfSearch Engine Optimization SEO PDF for 2024.pdf
Search Engine Optimization SEO PDF for 2024.pdf
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan
 
Take control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test SuiteTake control of your SAP testing with UiPath Test Suite
Take control of your SAP testing with UiPath Test Suite
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine Tuning
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptx
 
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptxE-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
 
SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024SIP trunking in Janus @ Kamailio World 2024
SIP trunking in Janus @ Kamailio World 2024
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clash
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platforms
 
Story boards and shot lists for my a level piece
Story boards and shot lists for my a level pieceStory boards and shot lists for my a level piece
Story boards and shot lists for my a level piece
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQL
 
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage CostLeverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
Leverage Zilliz Serverless - Up to 50X Saving for Your Vector Storage Cost
 

Enhancing ibm tivoli san manager device availability alerting redp3821

  • 1. Redbooks Paper Steve Strutt Enhancing IBM Tivoli SAN Manager Device Availability Alerting Introduction This Redpaper outlines how it is possible to enhance the real-time alerting of the availability status of SAN devices with the IBM® Tivoli® Storage Area Network Manager SAN management solution. The approach outlined here uses the industry standard FC Mgmt MIB implemented by most SAN devices to report device status information, irrespective of device type or vendor. The FC Mgmt MIB was originally created for just this task, providing for the reporting of device events, and monitoring and alerting on device and port status information, device internal temperature, and the availability of power supplies and fans. To minimize administrative effort, many organizations use event management consoles to monitor and manage their whole IT infrastructure on an exception management basis. Operations personnel can be alerted in real time to all issues relating to application availability. This also enables the use of a single consistent approach to alert and event management across the whole of IT, simplifying administration and reducing costs. The exploitation of the FC Mgmt MIB for the reporting of status and events enables SAN device availability information to be included as part of end-to-end application management. It helps ensure storage and application availability and reduces the risk of application outages by simplifying the job of storage administrators or operations personnel in monitoring and maintaining SAN devices. Accompanying scripts are provided to implement the features described in this paper. These scripts can be downloaded (in a ZIP archive called custom.zip) from the following URL: ftp://www.redbooks.ibm.com/redbooks/REDP3821/ Alternatively, you can go to the IBM Redbooks™ Web site at: http://ibm.com/redbooks Select Additional materials and open the directory that corresponds with the Redpaper form number, REDP3821. © Copyright IBM Corp. 2004. All rights reserved. ibm.com/redbooks 1
  • 2. Tivoli Storage Area Network Manager and availability alerting IBM Tivoli Storage Area Network Manager centralizes the management of a SAN fabric by bringing SAN topology discovery, mapping, and availability alerting to a central point. SAN topology is displayed on the SAN Manager console, which is updated in real time with the availability of the SAN fabric network. In addition, it provides alerting of changes in SAN topology and configuration through Simple Network Management Protocol (SNMP) traps and Tivoli Enterprise™ Console events. These topology change events are an essential part of a storage availability management solution. They enable administrators to identify changes that might have an impact on applications and enable rapid identification of the cause of application failures. To ensure high availability, many devices include redundant components such as power supplies and fans, because these electro-mechanical components have a relatively short life compared to any internal electronics. The individual failure of these components will not cause device failure, but will increase the exposure to the risk of further failures resulting in complete device failure, causing a significant SAN failure and availability issue. Currently, Tivoli Storage Area Network Manager alerts on the availability of the SAN fabric and the up or down status of the devices of which the fabric comprises. It does not alert on the health or availability status of individual SAN devices and internal components that are a working part of the SAN fabric. Only if a device fails will Tivoli Storage Area Network Manager alert that it has been removed from the fabric. Note that TSNAM does monitor the underlying health of the Fibre Channel links to predict an impending hard failure of the data transmission path. This function is the SAN Error Predictor doing Error Detection and Fault Isolation (ED/FI). The addition of availability status alerting using the FC Mgmt MIB as outlined in this paper enables the real-time detection of device failures or events that could impact the availability of a device, but have not yet caused the device to fail. This is particularly critical where redundant components are concerned. Figure 1 shows the overall structure of this device availability alerting solution. IBM Tivoli NetView® receives FC Mgmt MIB traps from devices and forwards these to Tivoli Storage Area Network Manager and additionally sends formatted FC Mgmt MIB events as SNMP traps to the NetView event log and as Tivoli Enterprise Console® events to the Tivoli Enterprise Console. Tivoli Storage Area Network Manager monitors the fabric topology, using the traps from NetView and in-band fabric events to trigger topology refreshes, and sends fabric availability events to a Tivoli Enterprise Console and the NetView event log. Topology/ NetView Configuration TSANM Event Log events TEC event FC Mgmt FC Mgmt TEC event Tivoli SNMP TSANM Enterprise SAN FC Mgmt traps Console Console Switches SNMP traps Tivoli NetView TSANM Windows 2000 Mgmt Server Figure 1 Tivoli Storage Area Network Manager and device availability alerting The addition of this capability to Tivoli Storage Area Network Manager provides an enhanced real-time availability monitoring and alerting solution for SAN fabrics and SAN components. 2 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 3. Tivoli Storage Area Network Manager alerts on the availability of the SAN fabric itself and the FC Mgmt traps on SAN device health and availability. Fabric and SAN availability alerting is only one part of end-to-end storage availability monitoring and management. To provide a comprehensive view of availability, information about all aspects of storage infrastructure that have a bearing on the availability of the LUNs and file systems used by applications must be integrated into a management solution. Table 1 shows the IBM software and hardware products which can be integrated into a single end-to-end storage availability management solution for IBM TotalStorage® environments. Table 1 Components of an IBM end-to-end storage availability monitoring solution Event source Storage Types of events component Storage device Tape storage (3494, 359x) Device - Tape Availability Disk storage (ESS, SVC, FAStT) Device - Disk Availability SAN switches Device - SAN Availability Storage application Tivoli NetView Device - SAN Availability Device FC Mgmt traps Tivoli Storage Area Network Manager Storage Network Availability Tivoli Storage Area Network Manager - Device - SAN Errors SAN Error Predictor Tivoli Storage Resource Manager LUNs Availability File systems Availability, Utilization The solution outlined here using FC Mgmt traps and NetView adds a key component to this, namely the alerting on SAN device availability and status. The alerting solution The FC Mgmt MIB definition includes four SNMP traps to indicate significant device events or a change in status of the device. The events and the information they impart are: Device state and status: Online/Offline, OK/Warning/Failed Environmental Sensors: Temperature, Power Supplies, Fans: OK/Warning/Failed Port Status: Online/Offline, OK/Warning/Failure Device Events: Internal device event details The FC Mgmt MIB trap information, as received by NetView, is largely as integer values to represent status information, not a textual description. In some cases, only the bare minimum of information is passed in the trap and is insufficient to completely identify the failing component or the severity of the event. To be useful, the integer values have to be converted to readable text and additional information retrieved from the device to make an alert that is easily readable and contains sufficient information to help determine the severity of the problem. This solution performs these functions, interpreting the events and querying the devices for more information to make the events more descriptive and useful. A number of elements on the Tivoli Storage Area Network Manager management server are used to implement this availability monitoring and alerting solution. As shown in Figure 1, the Enhancing IBM Tivoli SAN Manager Device Availability Alerting 3
  • 4. NetView instance on the Tivoli Storage Area Network Manager server already performs a number of functions, displaying the SAN topology (as a NetView map) and receiving and forwarding SNMP traps from SAN devices to Tivoli Storage Area Network Manager to trigger automatic topology refreshes. This NetView instance can also receive the device FC Mgmt traps and use these to query the sending device and its sensors status and send more detailed failure alerts to the NetView event log or Tivoli Enterprise Console. Figure 2 shows the execution flow for the monitoring and alerting solution described in this paper. Tivoli Storage Area Network Manager 4. Execute monitor script 2. FC Mgmt 3. Trap Trap Lookup Tivoli Enterprise Console NetView Tivoli 6. Issue Tivoli Enterprise NetView NetView Event Log Console event and new SNMP trap 1. FC Mgmt Trap 5. FC Mgmt MIB Queries SAN Switch Figure 2 Overview of the execution flow The following steps describe the execution flow for the monitoring and alerting solution: 1. NetView receives an FC Mgmt trap from a device that indicates a device event or change in state. 2. NetView forwards this event to Tivoli Storage Area Network Manager to trigger a topology refresh. 3. NetView looks up its definition for FC Mgmt traps. Associated with the trap is a script that should be executed on receipt of the trap. 4. The monitor and alerting script is called and executed. 5. The script executes NetView functions to query the FC Mgmt MIB on the device issuing the trap to return further details from the device. 6. A new SNMP trap or Tivoli Enterprise Console events, or both, are issued. These are in formatted text and show more detailed information. As shown in Figure 2, these new SNMP traps can be displayed in the NetView event log on the Tivoli Storage Area Network Manager server along with the Tivoli Storage Area Network Manager events about the availability of the SAN fabric, or on a Tivoli Enterprise Console. 4 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 5. Configuring the solution The following instructions show you the steps to configure NetView to provide detailed alerting and monitoring using FC Mgmt MIB traps. We refer to the installation package that you can download with this paper, SANenvmonitor.zip, or just “the package.” Installing the executables To install the SANenvmonitor.zip package, simply unzip it. It unzips to the directories customscripts and custombin. This paper assumes that the package is installed on the C: drive. Although any drive can be used, several scripts assume installation on the C drive; therefore, if this is not the case, these scripts will need to be edited to reflect the actual installation drive. The package includes an open source version of the Perl interpreter that comes from the Tivoli Framework installation CD. The executables for Perl are installed in the directory C:custombin. The path to the executables needs to be added to the Microsoft® Windows® PATH system environment variable. Environment variables can be changed from the Control Panel by selecting System Properties and clicking the Advanced tab. Figure 3 shows the addition of the directory C:custombin to the path. Figure 3 Edit the PATH environment variable This paper assumes that the scripts and other executables required are installed in the C:customscripts directory. To issue the event to Tivoli Enterprise Console, a copy of the Tivoli Enterprise Console Version 3.8 version of postemsg.exe is included with the package. This should be compatible with any version of Tivoli Enterprise Console. It is installed in the custom/scripts directory. Loading the FC Mgmt MIB For NetView to correctly query and interpret the contents of the FC Mgmt MIB on the monitored devices, the MIB definitions need to be loaded into NetView. To load the MIB definitions: 1. The MIB loader option is only available if the NetView advanced menus are activated. If the advanced menus are not already available, from the NetView Console menu, select Options → Advanced Menu. Stop and restart the console to activate the advanced menus. 2. Then, from the NetView Console menu, select Tools → MIB → Loader SNMP V1. This opens the MIB Loader panel, as shown in Figure 4. Enhancing IBM Tivoli SAN Manager Device Availability Alerting 5
  • 6. Figure 4 NetView MIB Loader panel 3. Click Load. Browse to the directory where the FC Mgmt MIB was installed (c:customscripts by default). Select the FC Mgmt MIB (v3_0FA.mib), and click Open to load the MIB. Triggering automatic execution A native capability of NetView is to execute commands on the receipt of traps, passing details of the received traps as variables when the command is executed. This ability is used to execute the monitoring and alerting script on receipt of one of the FC Mgmt traps. The trap definitions must be loaded into NetView for it to recognize the traps. Associated with this definition is the command to be executed and the variables to be passed to it. When configured, NetView will execute the script on receipt of an FC Mgmt MIB trap. Most SAN devices now support the FC Mgmt or Fibre Alliance (FA) 3.0 MIB and typically a copy of the MIB is supplied by the SAN device vendor. This solution assumes that the devices being monitored support this version of the MIB. A sample copy, v3_0FA.mib, is included in this package for use with the solution. To load the FC Mgmt trap definitions into NetView, the definitions supplied in the MIB file need to be converted into NetView addtrap commands, which are then executed to define the traps to NetView. The NetView mib2trap command is executed to create a batch file containing NetView addtrap commands to define the traps to NetView: mib2trap c:customscriptsv3_0FA.mib c:customscriptsv3_0FA.bat The generated batch file (v3_0FA.bat) should then be executed to register the trap definitions. Note that the directory path for the addtrap commands in the created batch file might need to be edited to point to the directory where NetView was installed. A sample output when executing v3_0FA.bat is shown in Example 1. Example 1 Output of executing v3_0FA.bat C:Customscripts>v3_0fa.bat C:usrOVbinaddtrap -l connUnitEventTrap -g 6 -s 4 -n fcmgmt -i 1.3.6.1.3.94 -o A -c LOGONLY -t 0 -S 1 -f - -F "$E $G $S $# args: $*" 6 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 7. trapd.conf file read Trap has been added. writing trapd.conf file... C:usrOVbinaddtrap -l connUnitSensorStatusChange -g 6 -s 5 -n fcmgmt -i 1.3.6.1.3.94 -o A -c LOGONLY -t 0 -S 1 -f - -F "$E $G $S $# args: $*" trapd.conf file read Trap has been added. writing trapd.conf file... ………….. After the batch file has been executed to add the trap definitions for the FC Mgmt MIB to NetView, the trap definition must be altered in NetView to execute the monitor script when the trap is received. This must be performed for each of the four different FC Mgmt MIB traps supported by this solution. The connUnitSensorStateChange trap is used as an example in the screen captions. The process for the other three traps is identical. The four traps are: connUnitEventTrap connUnitPortStatusChange connUnitSensorStateChange connUnitStatusChange To alter the trap definition: 1. From the NetView Console menu, select Options → Trap Settings. This opens the Trap Settings panel, as shown in Figure 5. Figure 5 NetView Trap Settings panel Enhancing IBM Tivoli SAN Manager Device Availability Alerting 7
  • 8. 2. In the top half of the panel (labeled Select an enterprise), highlight the fcmgmt enterprise. On the bottom half of the panel (labeled Select a trap), select the connUnitSensorStatusChange trap. Select Properties to open the Trap Properties panel, as shown in Figure 6. Figure 6 NetView Trap Properties for the connUnitSensorStatusChange trap 3. In the Run this command when the trap is received field, enter the directory and name of the script, followed by $A $S $-1 $2 “$4”, which passes the required variables from the original trap. $A is the source of the trap, $S is the trap number, and the other variables are data presented by the device in the traps. The full string will be: c:customscriptsfcmgmttraps.bat $A $S $-1 $2 “$4” 4. In the Run as field, select Hidden Application. This executes the script as a hidden application each time the trap is received. On some NetView instances, it has been found that the script does not execute when set to Hidden Application. If this is the case, the alternative option Console Application can be used. The Display the Trap Category as field is set to Only Log Event, so on receipt, the original unformatted FC Mgmt event is not displayed in the NetView event log, only the new formatted trap. Click OK. Enabling devices to be monitored Devices to be monitored must be configured to send FC Mgmt traps to NetView. Where the monitor is implemented on the NetView instance used by Tivoli Storage Area Network Manager, SAN switches will have already been configured to send their FC Mgmt events to this instance of NetView, and further configuration is not required. Any other devices to be monitored in this fashion must also be configured to route their FC Mgmt traps to NetView. In addition to switches, this can include fibre-to-SCSI gateways, storage arrays, and other SAN attached devices that also support the FC Mgmt MIB. Configuration of trap forwarding on devices usually also includes the ability to set the devices’ SNMP community name. All devices must be configured to use the same SNMP community name with read permissions to the FC Mgmt MIB variables. Make a note of this community name, because it is used later in the configuration. 8 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 9. Configuring the monitor A number of variables in the fcmgmttraps.pl script need editing to reflect local values. These include: $CommunityName: The SNMP community name used for read access to the FC Mgmt MIB variables on the monitored devices. $NV_PATH: NetView installation directory. $TEC_PATH: Installation path of the monitor script and Tivoli Enterprise Console configuration file. By default, the script sends both an SNMP trap and Tivoli Enterprise Console event. Depending on which event is needed, the script needs editing to specify whether or not to issue the SNMP trap or Tivoli Enterprise Console event. Displaying and formatting the events The new events issued by this solution map directly to the corresponding FC Mgmt MIB traps: SAN Event: connUnitEventTrap SAN Port: connUnitPortStatusChange SAN Environment: connUnitSensorStateChange SAN State: connUnitStatusChange Now, we show you how to configure NetView and Tivoli Enterprise Console to display these new events in the NetView event log and Tivoli Enterprise Console in formatted and readable text. Displaying the event in NetView To enable the new SNMP trap to be displayed in the NetView event log on the Tivoli Storage Area Network Manager server, a new trap definition is used to display and format the event. The definitions for these new traps are contained in the file fcmgmttrapdefs.bat in the scripts directory. The new trap definitions are added to the traps already defined for NetView, using high trap numbers to avoid conflict with existing trap definitions. Executing the batch file will define the new traps to NetView so that they can be properly displayed and formatted. Example 2 shows a sample execution of fcmgmttrapdefs.bat. Example 2 Sample execution output of fcmgmttrapdefs.bat C:customscripts>fcmgmttrapdefs C:>C:usrOVbinaddtrap -l SAN_Environment -g 6 -s 99000001 -n NetView -i 1.3.6.1.4.1.2.6.3 -o A -c "Status Events" -t 0 -S 1 -f - -F $1 trapd.conf file read Trap has been added. writing trapd.conf file... C:>C:usrOVbinaddtrap -l SAN_Event -g 6 -s 99000004 -n NetView -i 1.3.6.1.4.1.2.6.3 -o A -c "Status Events" -t 0 -S 1 -f - -F $1 trapd.conf file read Trap has been added. writing trapd.conf file... ……………………………….. Enhancing IBM Tivoli SAN Manager Device Availability Alerting 9
  • 10. To display the new trap definitions and verify that they have been loaded correctly: 1. From the NetView Console menu, select Options → Trap Settings. This opens the Trap Settings panel, as shown in Figure 7. Figure 7 Trap Settings panel for NetView enterprise 2. In the top half of the panel (labeled Select an Enterprise), highlight the NetView entry. This opens the list of defined NetView traps. Scroll down to the SAN_Environment trap and click Properties to display the details, as shown in Figure 8. Figure 8 Trap Properties panel 10 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 11. Displaying the event on Tivoli Enterprise Console To sent the event to a Tivoli Enterprise Console, the tecad_nt.conf file in the scripts directory needs to be modified to send events to the correct Tivoli Enterprise Console. The statements shown in Example 3 need to be changed to point to the Tivoli Enterprise Console server and port in your environment. Example 3 Statements to modify in the tecad_nt.conf file ServerLocation=sienna ServerPort=5529 To enable the event to be formatted and displayed on the Tivoli Enterprise Console server, the event class definitions for the events in the san.baroc file found in the scripts directory need to be loaded into the Tivoli Enterprise Console database. Details about how to load a baroc file can be found in Chapter 10, “Tivoli SAN Manager and Tivoli Enterprise Console,” of the IBM Redbook, IBM Tivoli Storage Area Network Manager: A Practical Introduction, SG24-6848. Tivoli Enterprise Console event information The information available in the FC Mgmt MIB about events, device availability, and status is fully documented in the v3_0FA.mib file contained in the package. The following fields are passed as part of the Tivoli Enterprise Console events: SAN Environment – UnitSensorName: Power Supply, Fan, Temperature Sensor – UnitSensorStatus: OK, Failed, Warning – UnitSensorMSG: More detailed information about sensor state SAN Port – Port State: Online, Offline, Bypassed – Port Status: OK, Failed, Warning, Initializing, Bypassed, Not Participating – PortHWStatus: Active, Failed, NoMedia, TxFault SAN Event – EventDesc: Description of the event – EventSeverity: Severity – EventRTime: Time of the event at the device – EventType: Type of event – EventIndex: Index to event in device event table SAN State – UnitState: Online, Offline – UnitStatus: OK, Warning, Failed Testing the final result The original FC Mgmt traps issued by the devices are not displayed in the NetView event log, because by default, they are “displayed” by NetView as Only Log Events and not written to the event log. To test the solution, this can be changed in the Trap Properties panel to Status Events so that they are displayed in the event log on receipt. It then becomes an easy job to check that when an original FC Mgmt trap is received the corresponding SAN trap generated by the script is also displayed. After it has been verified that the new traps are being correctly issued and displayed, the display category can be changed back to Only Log Event. If the script does not execute, and the new events issued when the execution mode of the script in the trap properties is set to Hidden Application, the alternative option, Console Application, can be used. Enhancing IBM Tivoli SAN Manager Device Availability Alerting 11
  • 12. Figure 9 shows examples of all the events shown on a Tivoli Enterprise Console and also in the NetView event log on the Tivoli Storage Area Network Manager. Figure 9 Events on Tivoli Enterprise Console and in the NetView event log If the events are not displayed as expected, the scripts santest.bat and santest.pl in the scripts directory can be used in place of the fcmgmttraps scripts to test that NetView is calling the scripts correctly and is passing the expected variables. If the events are displayed in NetView and on Tivoli Enterprise Console, but do not contain the expected information, the fcmgmttrap.bat file can be executed from a Windows command prompt with the appropriate variables. Samples of the expected variable input can be found in the file testinput.txt. Some of the variables need to be customized to local values for the scripts to retrieve information correctly from the switches and display it in the formatted events. The information displayed by the NetView trap issued by the santest scripts can be used for this purpose. QLogic SAN switches When testing the solution, we found that the traps from Brocade switches and InRange directors fully follow the trap definitions laid out in the FC Mgmt MIB 3.0 definitions and will trigger execution of the monitor script. However, QLogic switches, such as the SANBox2-16 (also rebadged by InRange), issue FC Mgmt traps under a different “enterprise,” and a modified set of trap definitions had to be loaded to trigger execution of the script. This is shown in Figure 10. 12 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 13. Figure 10 NetView Event Details for FC Mgmt trap from QLogic SANBox2-16switch The figure shows the Event Details in the NetView event log of a trap received from a QLogic SANBox2-16. Double-click the event in the log to get this view. It is shown unformatted because NetView does not recognize the event. The difference was found in the Enterprise number used by QLogic, which was 1.3.6.1.4.824.1.6. To create the correct set of trap definitions, the addtrap commands generated by the running the mib2trap command against the v3_0FA.mib file had to be edited to specify this new enterprise number before being executed. A new enterprise name of qlogicfcmgmt was used. All references in the batch file generated by the mib2trap command to fcmgmt were changed to qlogicfcmgmt, and the enterprise number was changed from 1.3.6.1.3.94 to 1.3.6.1.4.824.1.6 to reflect the enterprise number under which the traps are issued. Example 4 shows the execution output of the edited batch file. Example 4 Sample output of v3_0FA.bat edited to recognize QLogic events C:Customscripts>v3_0fa.bat C:Customscripts>C:usrOVbinaddtrap -l connUnitStatusChange -g 6 -s 1 -n qlogicfcmgmt -i 1.3.6.1.4.824.1.6 -o A -c LOGONLY -t 0 -S 1 -f - -F "$E $G $S $# args: $*" ……………… Setup and usage is the same as previously described. McData directors and switches Similarly, McData for their directors and switches use a variation of the standard FC Mgmt MIB. In this case, both the MIB and the traps use a different enterprise to that used by the “standard” FC Mgmt MIB. Figure 11 shows the traps generated with the default configuration. Enhancing IBM Tivoli SAN Manager Device Availability Alerting 13
  • 14. Figure 11 McData FC Mgmt trap with no NetView definition loaded This solution was tested with a McData Sphereon 4500. The FC Mgmt MIB definition file with a revision number of 200105080000Z was used. This MIB file was in SNMP v2 format, and a copy can be found in the custom/scripts directory as fcmgmt.mib. This version of the FC Mgmt MIB has to be loaded into NetView using the loadmibv2 program, which is in the usr/ov/bin NetView installation directory. Because the MIB file is in SNMP v2 format, the mib2trap command cannot be used to create the addtrap commands to define the FC Mgmt traps to NetView. A batch file, fcmgmttrapdefsmcdata.bat, is included in the scripts directory containing the correct addtrap commands. After the fcmgmtmcdata.bat batch file has been executed, and the traps have been defined, the trap properties need to be modified similarly to the QLogic devices, as described in “Triggering automatic execution” on page 6. Two McData specific scripts are included, fcmgmttrapsmcdata.pl and fcmgmttrapsmcdata.bat, which are specific to the McData implementation of the FC Mgmt MIB. As a result, the script to be executed on receipt of an FC Mgmt trap by NetView is fmgmttrapsmcdata.bat. Because McData passes slightly different information in the traps, the details of variables passed on each script are slightly different. For connUnitEventTrap, connUnitPortStatusChange, and connUnitSensorStateChange, it is similar to as before: c:customscriptsfcmgmttrapsmcdata.bat $A $S $-1 $2 “$4” For connUnitEventTrap, it is: c:customscriptsfcmgmttrapsmcdata.bat $A $S $-2 $2 “$4” 14 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 15. Summary This paper has shown how it is possible to enhance the Tivoli Storage Area Network Manager SAN management solution with real-time device health and availability alerting. This is an important component of an end-to-end monitoring solution for storage availability management. It enables failures which are not yet impacting application availability to be addressed before they can have an impact. Sending these events to a central point and displaying them on an event console such as the Tivoli Enterprise Console provides a single point for administrators to view storage events relating to the entire storage infrastructure. More significantly, this single view allows correlation between events to be performed, enabling more rapid identification of the root cause of failures, as well as reducing administrative effort in monitoring a heterogeneous multivendor storage environment. Figure 12 shows Tivoli Storage Area Network Manager events and the formatted FC Mgmt events as created by this solution displayed on a Tivoli Enterprise Console in conjunction with events from other applications. Figure 12 Tivoli Storage Area Network Manager and formatted FC Mgmt events on Tivoli Enterprise Console Enhancing IBM Tivoli SAN Manager Device Availability Alerting 15
  • 16. The team that wrote this Redpaper Steve Strutt is a Certified IT Specialist in the U.K., working in Technical Sales Support. He holds a bachelor's degree in Electronic Engineering and has more than 18 years of experience in IBM storage and storage management tools from z/OS to open systems storage. His areas of expertise include enterprise storage architecture, tape storage systems, Tivoli Storage Manager, Storage Area Networking, and Storage Resource Management and systems management. Thanks to the following people for their invaluable contributions to this and the previous edition of this Redpaper: Charlotte Brooks Emma Jacobs International Technical Support Organization, San Jose Center Elizabeth Barnes International Technical Support Organization, Austin Center Richard Hine Tivoli Systems, U.K. 16 Enhancing IBM Tivoli SAN Manager Device Availability Alerting
  • 17. Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing, IBM Corporation, North Castle Drive Armonk, NY 10504-1785 U.S.A. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrates programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. You may copy, modify, and distribute these sample programs in any form without payment to IBM for the purposes of developing, using, marketing, or distributing application programs conforming to IBM's application programming interfaces. © Copyright IBM Corp. 2004. All rights reserved. 17
  • 18. Send us your comments in one of the following ways: Use the online Contact us review redbook form found at: ibm.com/redbooks ® Send your comments in an Internet note to: redbook@us.ibm.com Mail your comments to: IBM Corporation, International Technical Support Organization Dept. QXXE Building 80-E2 650 Harry Road San Jose, California 95120-6099 U.S.A. Trademarks The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: IBM® Redbooks™ Tivoli Enterprise™ ibm.com® Redbooks(logo) ™ Tivoli Enterprise Console® NetView® Tivoli® TotalStorage® The following terms are trademarks of other companies: Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, and service names may be trademarks or service marks of others. 18 Enhancing IBM Tivoli SAN Manager Device Availability Alerting