Coal
Electricity Generation From
Coal
• Let’s start at the beginning.
• Almost everything in our homes and
businesses today run on electricity.
• That electricity has to come from somewhere.
• Some sources of electricity are nuclear power,
solar power, wind power, and most important
for us Coal Power.
The Process
• Coal was used to heat water in boiler room pipes to
produce steam
• The steam was used in a reciprocating (piston)
steam engine to produce mechanical energy
• The mechanical energy was converted into
electricity by a dynamo (generator)
Inside the dynamo room
www.nps.gov
Boiler plant can be divided in to three parts.
i) water circuit
ii) steam circuit
iii) The air and fuel gas circuit.
1) Water circuit
In the water circuit, water is fed from the boiler feed pumps into the boiler
through economiser. In the economiser, it receives some heat from the
departing flue gas before it goes to the boiler drum. The drum acts as a
reservoir for the various water walls of the boiler and also acts as a
separation chamber where water is removed from the steam before the
steam goes to the superheaters.
From the boiler drum the water passes down through pipes called down
comers to headers at the bottom of the boiler water walls.
The tubes which makeup the walls contain a mixture of
steam bubbles and water. This mixture being low dense
than water in the down comers, rises rapidly and reaches
back to the drum and its place is taken by the water
flowing through down comers. This produces what we call
is natural circulation.
The steam and water mixture which is returned to the
drum is separated so that water only (with no steam
bubbles) is returned to the down comers, and steam
only(with no water droplets) passed to the super heaters.
2) Steam circuit
Dry steam from the boiler drum goes to the various
superheater sections. Steam from the boiler drum passes
through the superheater connecting tubes to the primary
superheater, which is positioned in the convection pass.
The steam then flows from the primary superheater outlet
header to the secondary superheater located in the
combustion chamber.
Steam then goes to the final superheater which is located in
the combustion chamber in the outlet section, it then leaves
the final super heater outlet header and passes to the main
stem pipe which has a boiler stop valve.
3)Air/gas circuit
To burn the fuel in the combustion chamber air is required. After
combustion, the hot gases are to be evacuated from furnace through the
heat absorbing surfaces. This air and gas flow is created by the boiler
draught system, which may be either natural or mechanised.
The air drawn from the atmosphere is first routed through an air heater
where air is heated by the outgoing flue gases. The hot air is then admitted
to the furnace through wind box. In coal fired boilers part of this hot air is
used for drying the coal in the pulvariser and transporting the pulvarised
coal to furnace.
The gases pass through the radiant heat release zone and then through
various superheaters and reheaters (in reheat boilers). Normally there will
be a primary superheater and secondary superheater.
After passing through the air heater the flue gas goes to the chimney. In
between the air heater and chimney it is customary to provide
precipitator to remove the flyash from the flue gas (especially in coal
fired boilers) and induced draught fans to suck out the flue gases from
the furnace (in balanced draught/induced draught boilers).
water is the working medium which transfers the heat energy available in
the fuel to the turbine in the form of steam.
22° C reduction in flue gas temperature increases boiler efficiency by 1%
Water is chosen as the medium because of the
following reasons.
a) its easy availability
b) its low viscous property
c) it has high specific heat
d) Its non-reactivity with surfaces with which it comes in
to contact.
The following can be termed as boiler
pressure parts.
1. Boiler drum
2. Water walls
3. Superheaters
4. Reheaters and
5. Economisers
BOTTOM RNG HDR& Z-PANEL 1ST
PASS W.W
1ST
PASS W.W O/L HDRS ROOF I/L HEADER
2ND
PASS UPPER C-HDR 2nd
PASS LOWER C-HDRS
LTSH I/L HEADER LTSH O/L HEADER
D.P.I/L HEADER D.P.O/L HEADER
S.H. HEADER R.H.HEADER
2ND
PASS ROOF O/L HDR(REAR ECONOMISER
M.S
H.
R.
HC.R.H
FROM F.R.S
Steam Generator
Bottom
Ash Hopper
Bottom
Ring Header
Economiser
LTSH
Eco Hopper
Drum
Final SH
Furnace
ReheaterPlaten SH
Front Pass
Rear Pass
Goose Neck
Water Walls
Pent House
Steam cooled
Walls
Air Pre Heater
Wind Box
Burners
Platen SH.
375C-425C
Final SH.
500-540C
Economizer
240-310C
LTSH
330-375C
Water Wall
310C
210 MW Boiler: Water and Steam Circuit
BOILER DRUM
The drum acts as reservoir for water &
saturated steam and also provides
separation and purification of steam.
The feed water to the drum reaches
the drum from the boiler feed pump via
the economizer.
A stronger material for use in boiler
drums is Ducal W30.
Methods of Steam Separation:
1. By Gravity separation
This is employed for boilers having low generation rates.
2. By use of Baffles
These are in the form of obstacles in the direct path of steam towards outlet.
WATER WALL SYSTEM:
In the boiler the walls of the combustion chamber are
formed by tubular wall sections which not only form the
enclosure for the furnace but also provides the
evaporating surface for the feed water.
The water from the boiler drum is admitted in to the
water wall tubes through the downcomers and bottom
ring headers.
As the water circulates through the waterwall tubes,
which receive heat from the furnace radiation, water
partially evaporates into steam.
Water-steam mixture then return back to the boiler
drum.
SUPER HEATERS:
Super heaters (SH) are meant for raising the steam temperature above the
saturation temperature.
The superheated and reheated steam temperature around 540°C and pressure 165
bar.
i) SH (Reheater also) can classified into convection and radiation type
as per heat transfer process.
The super heaters and reheaters which are placed above the furnace and can view
the flame are called radiant type.
ii) Super heater may be classified also according to the shape of the tube banks
and the position of the headers, such as pendant SH, platen SH, horizontal SH,
Ceiling SH, wall SH etc.
iii) They may be classified according to their stages of superheating they perform,
like primary SH, Secondary SH, Final SH etc.
Reheaters:
Reheaters (RH) are provided to raise the temperature of the steam
from which part of energy has already been extracted by HP turbine.
De-superheaters:
Though super heaters are designed in such a way that heat
absorbed by radiant and convection super heaters always try
to maintain the steam temperature constant in practice the
necessary control is achieved by using de-super heater.
All modern boiler contact type de-super heaters by which feed water are sprayed
directly into the steam for required cooling.
Amount of feed water to be sprayed is controlled by automatic control system
which is designed to maintain a set final steam temperature. Provision of manual
control is also there for emergency.
ECONOMISERS:
The economiser absorbs heat from the flue
gas and adds it mainly as sensible heat to the
feed water.
The material used in the manufacture of
furnace wall tubes for coal fired boiler is
ordinary carbon steel but in the 500 MW oil
fired units the major proportion of the furnace
is constructed from the 1% Cr. ½% Mo Alloy.
In 660 MW units also this material is used for
whole of the furnace.
The Boiler Auxiliaries :
• Draft system
• Air heaters
•Milling systems
•Electrostatic precipitators,
etc.
DRAFT SYSTEM:
• The combustion process in a furnace can take place only when it
receives a steady flow of Air and has the combustion gases
continuously removed.
• The Boiler draft system includes Air and Flue gas flow.
• All modern large utility boilers are fired under "balanced draft"
condition, i.e. where draft is zero. This condition is created by the
combination of "forced draft" and "Induced draft".
SOOT BLOWERS
• deposits resulting from the combustion of coal will be deposited on
the boiler tubes at various zones will be cleaned by soot blowing for
effective heat transfer while on-load.
AIR HEATERS:
• The air heater is required for efficient combustion in the furnace and
also for drying wet coal in the milling plant. to recover "waste" heat
from the flue gas to increase boiler efficiency
AIR PREHEATER
MILLING PLANT :
• raw coal from the bunker is fed at a regulated rate to the mills through
a feeder.
• Air required for drying and transporting the pulverized coal from the
mill is obtained from the FD fan.
• Hot air is drawn through air heaters and cold air directly from FD fan
discharge.
• The drying and grinding takes place inside the mills. The pulverized
particles are being carried from the mill to the classifier, which is
directly mounted on the mill.
• The medium is directed into the burners through various fuel
pipelines.
Type of Pulverizers:
Drum/Tube mills:
Ball mills:
Bowl mills:
ELECTROSTATIC PRECIPITATORS:
Working Principle:
• The principles upon which an electrostatic precipitator
operates are that the dust laden gases pass into a
chamber where the individual particles of dust are given
an electric charge by absorption of free ions from a high
voltage D.C. ionising field.
• They are removed by an intermittent blow usually
referred to as rapping. This causes the dust particles to
drop into dust hoppers situated below the collecting
electrodes.
The following fans are used in the boiler houses:
1. Forced Draft fan (F.D. Fan):
To take air from atmosphere to supply all the Combustion air. Speeds vary between
600 to 1500 r.p.m.
2. Induced Draft Fan (I.D. Fan):
Used only in balanced draft units to suck the gases out of the furnace and throw them
into the stack.
Handles flue gases at temperatures of 125 to 200o
C.
Speed generally does not exceed 1000 rpm.
3. Primary Air Fans (P.A. Fans) or Exhauster Fan:
Used for pulverized system
Primary air has got two functions viz. Drying the coal and transportation into the
furnace.
Usually 1500 r.p.m.
Stator Casing
Ece.umr.edu
Steam Turbine
• As mentioned before,
something has to turn the
rotor in order to generate
electricity.
• In our case the prime mover
happens to be a steam
turbine.
• Steam comes out of the tubes
in the boiler and into a
manifold then into the turbine.
• As the steam passes over the
turbine blades, torque is
produced as a result of the
blade shape.
Steam Turbine
Wikipedia
Turbine Generator and Condenser
Steam Turbine
• The rate of steam flow controls how fast the turbine
rotates and therefore the frequency of the electricity
produced.
• As the steam moves through the turbine energy is
extracted which results in a pressure drop.
• Therefore the LP turbine is located at the exit of the
HP turbine to extract the maximum amount of
energy from the steam before it is sent to the
condenser.
• As electricity is generated it leaves the building
though a very large circuit breaker and a series of
transformers before it enters the power grid.
Path of Electricity
Control Room
Condenser
• After the steam leaves the LP turbine it travels to the
condenser, where it is condensed back to liquid
water.
• The condenser is a heat exchanger that cools the
steam while is passes over tubes that have cold
water running through them.
• The cold water removes energy from the heated
steam causing it to condense which is necessary for
the water to be re-used as feed.
• There is another reason why the condenser is
necessary which we will discuss shortly.
Cooling Towers
• The water that runs through the tubes in the
condenser must be cooled down in order to
condense the steam.
• This is accomplished using very large cooling
towers, in which the water is atomized by
sprayers and cooled down by atmospheric
conditions and fans.
• The substance leaving cooling towers is
sometimes mistaken for smoke, but it is in fact
just water vapor.
Cooling Towers
Cooling Tower
Main Condenser
Holte International
Feed System
• After the condensate is collected in the
hotwell of the condenser it is pumped through
the feed system.
• The feed pump increases the pressure of the
feed water in order for it to flow back into the
boiler to be turned back into steam to start
the cycle over again.
• This stage turns out to be the 4th
and final
stage of something called a heat engine.
Basic Heat Engine
Laws of Thermodynamics
• 1st
: “The increase in internal energy of a system
is equal to the amount of heat energy added
to the system minus the work done by the
system on the surroundings.”
Laws of Thermodynamics
• 2nd
: The temperature differences between systems in
contact with each other tend to even out and that work
can be obtained from these non-equilibrium differences,
but that loss of heat occurs, in the form of entropy, when
work is done.
• 2nd
: It is impossible to produce work in the surroundings
using a cyclic process connected to a single heat
reservoir (Kelvin, 1851).
Laws of Thermodynamics
• The second law also states that the maximum
efficiency of a heat engine can be determined by:
η = 1-(Th/Tc)
• Efficiency is also equal to the work output over the
heat input.
η = Δ W/Δ QH
Efficiency
• An ordinary power plant operates between
the temperatures of 565C and 25C which leads
to maximum efficiency of around 64%.
• However, due to the losses mentioned earlier
the usual observed efficiency is about 35%.
• This shows how much of the energy stored in
the coal is just wasted instead of being
converted to electricity.
Steam Cycle
• The previous part of the presentation was to
explain the process behind electricity
generation that occurs after the coal portion.
• I will now go through some of the
components dealing with the coal aspect of
the power plant ending at the boiler which is
where the steam cycle began.
• Most of what I will discuss is particular to the
Co-gen plant that I visited.
Coal Delivery
• After the coal is mined and loaded into trucks
it is delivered into chutes that lead to the
Bradford Breaker.
• The breaker is a drum with hammers in it that
rotates and breaks the coal down into pieces
about 4” diameter, which fall through the
screen and onto the conveyor belt which leads
to the storage facility.
Bradford Breaker
www.penncrusher.com
Bradford Breaker
Coal Storage
• After the coal has been sufficiently reduced in
size, it enters a storage facility, in this case, a
large dome.
• The coal is then stacked using a machine you
will see in the next slide, which rotates and
places the coal around the perimeter of the
dome.
• This same machine also takes coal from the
pile and delivers it to the crusher building.
Coal Storage
Crusher
• The coal is delivered from the storage facility to a
device conveniently called a coal crusher.
• This machine takes the 4” pieces of coal and through
a series of rollers converts the fuel into a fine
powder.
• This powder is necessary for proper combustion in
the boilers.
• All newer state of the art power plants are set up to
work with pulverized coal, but older plants may
operate with lumped coal.
Crusher
Crusher
Fuel Feed System
• The conveyor belt
delivers the crushed
coal to a series of fuel
feeders, which inject
coal into the boilers
along with a mixture of
high pressure air for
combustion.
Boiler Base
Boiler Building
Boilers
• The final stage for the coal coincides with the
first stage of the steam plant.
• The boiler is usually the largest component of
the coal power plant climbing as high as 200 ft.
• Inside the boilers the pulverized coal is burned
while it more or less floats with the aid of HP
air.
• Lining the entire inside of the boiler are tubes
which carry the feed water to be turned into
steam.
Boilers
www.boatnerd.com
Boiler
Wikipedia
Inside the Boiler
news.minnesota.publicradio.org
After the Boiler
• As the coal is burned a large amount of ash is
produced.
• Some falls to the bottom and is collected, then
mixed with water and sent to the ash pile.
• Very light ash particles also escape with the
exhaust gasses which are captured by a bag
filter system.
• This fly ash is collected in a silo until a certain
level is reached when it is pumped to the ash
pile via HP air.
Fly Ash
www.concretethinker.com
Ash Pile
Ash
• This ash has a basic pH and has
some beneficial uses.
• After a truck delivers coal to the
plant it is filled with ash to return to
the reclamation site.
• The high pH helps treat acid mine
drainage.
Ash
• The fly ash is used as a substitute to
make Portland cement.
• Another use of fly ash is structural
fill for highway embankments and
the fill under new highways.
Exhaust Gasses and the Stack
• One of the most controversial aspects of a coal
power plant is what comes out of the stack.
• During the combustion process dangerous
gasses and particulates are released, such as
NOx, SOx, and CO2.
• Controls are in effect for each of these in new
plants, however older plants spew thousands of
pounds of each of these into the atmosphere
every year.
Intermittent Blowdown
• The intermittent blown down is given by manually
operating a valve fitted to discharge pipe at the lowest
point of boiler shell to reduce parameters (TDS or
conductivity, pH, Silica etc) within prescribed limits so
that steam quality is not likely to be affected
• TDS level keeps varying
• fluctuations of the water level in the boiler.
• substantial amount of heat energy is lost with
intermittent blow down.
Continuous Blowdown
• A steady and constant dispatch of small
stream of concentrated boiler water, and
replacement by steady and constant inflow
of feed water.
• This ensures constant TDS and steam
purity.
• This type of blow down is common in high-
pressure boilers.
Boiler Water Treatment
• Internal Water Treatment: It is carried out by adding
chemicals to boiler to prevent the formation of scale by
converting the scale-forming compounds to free-flowing
sludges, which can be removed by blowdown.
• Limitation: Applicable to boilers, where feed water is
low in hardness salts, to low pressures- high TDS content
in boiler water is tolerated, and when only small
quantity of water is required to be treated.
• Internal treatment alone is not recommended.
External Water Treatment
• Propose: External treatment is used to remove suspended
solids, dissolved solids (particularly the calcium and
magnesium ions which are a major cause of scale formation)
and dissolved gases (oxygen and carbon dioxide).
• Different treatment Process :
– ion exchange;
– demineralization;
– reverse osmosis and
– de-aeration.
Demineralization
• Demineralization is the complete removal of all salts.
• This is achieved by using a “cation” resin, which exchanges the cations
in the raw water with hydrogen ions, producing hydrochloric, sulphuric
and carbonic acid.
• Carbonic acid is removed in degassing tower in which air is blown
through the acid water.
• Following this, the water passes through an “anion” resin which
exchanges anions with the mineral acid (e.g. sulphuric acid) and forms
water.
• Regeneration of cations and anions is necessary at intervals using,
typically, mineral acid and caustic soda respectively. The complete
removal of silica can be achieved by correct choice of anion resin.
De-aeration
• When heated in boiler systems, carbon dioxide
(CO2
) and oxygen (O2
) are released as gases and
combine with water (H2
O) to form carbonic acid,
(H2
CO3
).
Deaerator
•In de-aeration,
dissolved gases, such
as oxygen and carbon
dioxide, are expelled
by preheating the feed
water before it enters
the boiler.
Exhaust Gasses and the Stack
The Stack
www.industcards.com/as-pontes.jpg
Reduce Stack Temperature
• Stack temperatures greater than 200°C
indicates potential for recovery of waste heat.
• It also indicate the scaling of heat
transfer/recovery equipment and hence the
urgency of taking an early shut down for
water / flue side cleaning.
22o
C reduction in flue gas temperature
increases boiler efficiency by 1%
THANK YOU
Questions?

Mais conteúdo relacionado

Mais procurados

Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlHossam Zein
 
Thermal power plant efficiency
Thermal power plant efficiencyThermal power plant efficiency
Thermal power plant efficiencyManohar Tatwawadi
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plantSHIVAJI CHOUDHURY
 
Feedwater heaters by Himanshu Vaid
Feedwater heaters by Himanshu VaidFeedwater heaters by Himanshu Vaid
Feedwater heaters by Himanshu VaidHimanshu Vaid
 
Yokogawa Presantesation(1)
Yokogawa Presantesation(1)Yokogawa Presantesation(1)
Yokogawa Presantesation(1)Maulik kunjadiya
 
01 regenerative feed heating
01 regenerative feed heating01 regenerative feed heating
01 regenerative feed heatingAnil Palamwar
 
Boiler instrumentation-and-controls
Boiler instrumentation-and-controlsBoiler instrumentation-and-controls
Boiler instrumentation-and-controlsDARSHAN B S
 
Indian scenario of super critical power plants issues and challenges by ntpc...
Indian scenario of super critical power plants  issues and challenges by ntpc...Indian scenario of super critical power plants  issues and challenges by ntpc...
Indian scenario of super critical power plants issues and challenges by ntpc...Ajay Singhal
 
Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Lossesguest81e1c7
 
Adiabatic cooling tower v3 08.08
Adiabatic cooling tower v3 08.08Adiabatic cooling tower v3 08.08
Adiabatic cooling tower v3 08.08Er Ramgarhia
 
Practical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & TechniciansPractical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & TechniciansLiving Online
 
Performance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantPerformance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantIAEME Publication
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plantsSHIVAJI CHOUDHURY
 
Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Hammad Akber
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERGopi Chand
 

Mais procurados (20)

Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater control
 
Super critical boiler
Super critical boilerSuper critical boiler
Super critical boiler
 
Thermal power plant efficiency
Thermal power plant efficiencyThermal power plant efficiency
Thermal power plant efficiency
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plant
 
Feedwater heaters by Himanshu Vaid
Feedwater heaters by Himanshu VaidFeedwater heaters by Himanshu Vaid
Feedwater heaters by Himanshu Vaid
 
BOILER INSTRUMENTATION
BOILER INSTRUMENTATIONBOILER INSTRUMENTATION
BOILER INSTRUMENTATION
 
Yokogawa Presantesation(1)
Yokogawa Presantesation(1)Yokogawa Presantesation(1)
Yokogawa Presantesation(1)
 
01 regenerative feed heating
01 regenerative feed heating01 regenerative feed heating
01 regenerative feed heating
 
Boiler instrumentation-and-controls
Boiler instrumentation-and-controlsBoiler instrumentation-and-controls
Boiler instrumentation-and-controls
 
Indian scenario of super critical power plants issues and challenges by ntpc...
Indian scenario of super critical power plants  issues and challenges by ntpc...Indian scenario of super critical power plants  issues and challenges by ntpc...
Indian scenario of super critical power plants issues and challenges by ntpc...
 
Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Losses
 
Adiabatic cooling tower v3 08.08
Adiabatic cooling tower v3 08.08Adiabatic cooling tower v3 08.08
Adiabatic cooling tower v3 08.08
 
High Pressure Boilers
High Pressure BoilersHigh Pressure Boilers
High Pressure Boilers
 
Practical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & TechniciansPractical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & Technicians
 
Performance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantPerformance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plant
 
Air heater
Air heaterAir heater
Air heater
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plants
 
Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)
 
Boiler operation (2)
Boiler operation (2)Boiler operation (2)
Boiler operation (2)
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZER
 

Semelhante a Coalfiredelectricpowerplants23 131208122612-phpapp01

Coal fired electric power plants23
Coal fired electric power plants23Coal fired electric power plants23
Coal fired electric power plants23Munna Sagar
 
Boilers ps mrng sessn
Boilers ps mrng sessnBoilers ps mrng sessn
Boilers ps mrng sessnInes Kkumar
 
Boilers ps mrng sessn
Boilers ps mrng sessnBoilers ps mrng sessn
Boilers ps mrng sessnInes Kkumar
 
Overview of Thermal Power Plants
Overview of Thermal Power PlantsOverview of Thermal Power Plants
Overview of Thermal Power PlantsDebajyoti Bose
 
Thermal Power Station
Thermal Power StationThermal Power Station
Thermal Power StationDinesh Sharma
 
SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT
SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT
SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT Amit Gupta
 
Panipat thermal power station training ppt
Panipat thermal power station training pptPanipat thermal power station training ppt
Panipat thermal power station training pptMohit Verma
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plantVivek Pathak
 
Power Plant Engg.pdf
Power Plant Engg.pdfPower Plant Engg.pdf
Power Plant Engg.pdfBARUNBIKASHDE
 
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...Shubham Thakur
 
Coal Base Thermal Power Plant
Coal Base Thermal Power PlantCoal Base Thermal Power Plant
Coal Base Thermal Power PlantPankaj Mohan
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plantViren Patel
 
Thermalpwrplant 110924082908-phpapp02
Thermalpwrplant 110924082908-phpapp02Thermalpwrplant 110924082908-phpapp02
Thermalpwrplant 110924082908-phpapp02arvind singh rathore
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plantVinay Garg
 
Kota super thermal power plant,kstps ppt,RTU
Kota super thermal power plant,kstps ppt,RTUKota super thermal power plant,kstps ppt,RTU
Kota super thermal power plant,kstps ppt,RTUManohar Nagar
 
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptx
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptxCOAL BASED THERMAL POWER PLANTS (UNIT-1).pptx
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptxCHANDRA KUMAR S
 

Semelhante a Coalfiredelectricpowerplants23 131208122612-phpapp01 (20)

Coal fired electric power plants23
Coal fired electric power plants23Coal fired electric power plants23
Coal fired electric power plants23
 
Boilers ps mrng sessn
Boilers ps mrng sessnBoilers ps mrng sessn
Boilers ps mrng sessn
 
Boilers ps mrng sessn
Boilers ps mrng sessnBoilers ps mrng sessn
Boilers ps mrng sessn
 
Overview of Thermal Power Plants
Overview of Thermal Power PlantsOverview of Thermal Power Plants
Overview of Thermal Power Plants
 
Thermal Power Station
Thermal Power StationThermal Power Station
Thermal Power Station
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT
SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT
SUMMER INTERNSHIP(INDUSTRAIL REPORT) ON THERMAL POWER PLANT
 
Panipat thermal power station training ppt
Panipat thermal power station training pptPanipat thermal power station training ppt
Panipat thermal power station training ppt
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
Power Plant Engg.pdf
Power Plant Engg.pdfPower Plant Engg.pdf
Power Plant Engg.pdf
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...
Thermal Power Plant - Full Detail About Plant and Parts (Also Contain Animate...
 
Coal Base Thermal Power Plant
Coal Base Thermal Power PlantCoal Base Thermal Power Plant
Coal Base Thermal Power Plant
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
Thermalpwrplant 110924082908-phpapp02
Thermalpwrplant 110924082908-phpapp02Thermalpwrplant 110924082908-phpapp02
Thermalpwrplant 110924082908-phpapp02
 
CFBC boiler operation
CFBC boiler operationCFBC boiler operation
CFBC boiler operation
 
Ppt aman
Ppt amanPpt aman
Ppt aman
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
Kota super thermal power plant,kstps ppt,RTU
Kota super thermal power plant,kstps ppt,RTUKota super thermal power plant,kstps ppt,RTU
Kota super thermal power plant,kstps ppt,RTU
 
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptx
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptxCOAL BASED THERMAL POWER PLANTS (UNIT-1).pptx
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptx
 

Mais de arvind singh rathore (20)

Indiapresentation 090518123848-phpapp02
Indiapresentation 090518123848-phpapp02Indiapresentation 090518123848-phpapp02
Indiapresentation 090518123848-phpapp02
 
Grid standards reg
Grid standards regGrid standards reg
Grid standards reg
 
Grid stds
Grid stdsGrid stds
Grid stds
 
Turbo generator & its auxiliaries
Turbo generator & its auxiliariesTurbo generator & its auxiliaries
Turbo generator & its auxiliaries
 
Case studies in steam system auditing
Case studies in steam system auditingCase studies in steam system auditing
Case studies in steam system auditing
 
Generator grid connection_guide
Generator grid connection_guideGenerator grid connection_guide
Generator grid connection_guide
 
Turbinecontrolbasic
TurbinecontrolbasicTurbinecontrolbasic
Turbinecontrolbasic
 
Basic plc-programming
Basic plc-programmingBasic plc-programming
Basic plc-programming
 
Analog output
Analog outputAnalog output
Analog output
 
Transformer guide
Transformer guideTransformer guide
Transformer guide
 
Controller
ControllerController
Controller
 
ge turbine
 ge  turbine ge  turbine
ge turbine
 
steam turbine presentations
steam turbine presentationssteam turbine presentations
steam turbine presentations
 
Steamturbine 140203094808-phpapp01
Steamturbine 140203094808-phpapp01Steamturbine 140203094808-phpapp01
Steamturbine 140203094808-phpapp01
 
Thermalpowerpoint 130818150844-phpapp01
Thermalpowerpoint 130818150844-phpapp01Thermalpowerpoint 130818150844-phpapp01
Thermalpowerpoint 130818150844-phpapp01
 
4.1.3 properties of coals
4.1.3 properties of coals4.1.3 properties of coals
4.1.3 properties of coals
 
Power quality
Power qualityPower quality
Power quality
 
Ntpc2 111125042448-phpapp02
Ntpc2 111125042448-phpapp02Ntpc2 111125042448-phpapp02
Ntpc2 111125042448-phpapp02
 
An article on fuel
An article on fuelAn article on fuel
An article on fuel
 
Steam turbine oil_challenges
Steam turbine oil_challengesSteam turbine oil_challenges
Steam turbine oil_challenges
 

Coalfiredelectricpowerplants23 131208122612-phpapp01

  • 2. IIMT INSTITUTE OF ENGINEERING & TECHNOLOGY ELECTRICITY GENRATION FROM COAL Presented by: MUNNA KUMAR B.Tech(E.C.-’G1’) 4th yr. Roll no.- 1037131040 Submitted to:- Dr. P. K Singh (seminar co-ordinator)
  • 4. Electricity Generation From Coal • Let’s start at the beginning. • Almost everything in our homes and businesses today run on electricity. • That electricity has to come from somewhere. • Some sources of electricity are nuclear power, solar power, wind power, and most important for us Coal Power.
  • 5. The Process • Coal was used to heat water in boiler room pipes to produce steam • The steam was used in a reciprocating (piston) steam engine to produce mechanical energy • The mechanical energy was converted into electricity by a dynamo (generator) Inside the dynamo room www.nps.gov
  • 6.
  • 7. Boiler plant can be divided in to three parts. i) water circuit ii) steam circuit iii) The air and fuel gas circuit. 1) Water circuit In the water circuit, water is fed from the boiler feed pumps into the boiler through economiser. In the economiser, it receives some heat from the departing flue gas before it goes to the boiler drum. The drum acts as a reservoir for the various water walls of the boiler and also acts as a separation chamber where water is removed from the steam before the steam goes to the superheaters. From the boiler drum the water passes down through pipes called down comers to headers at the bottom of the boiler water walls.
  • 8. The tubes which makeup the walls contain a mixture of steam bubbles and water. This mixture being low dense than water in the down comers, rises rapidly and reaches back to the drum and its place is taken by the water flowing through down comers. This produces what we call is natural circulation. The steam and water mixture which is returned to the drum is separated so that water only (with no steam bubbles) is returned to the down comers, and steam only(with no water droplets) passed to the super heaters.
  • 9. 2) Steam circuit Dry steam from the boiler drum goes to the various superheater sections. Steam from the boiler drum passes through the superheater connecting tubes to the primary superheater, which is positioned in the convection pass. The steam then flows from the primary superheater outlet header to the secondary superheater located in the combustion chamber. Steam then goes to the final superheater which is located in the combustion chamber in the outlet section, it then leaves the final super heater outlet header and passes to the main stem pipe which has a boiler stop valve.
  • 10. 3)Air/gas circuit To burn the fuel in the combustion chamber air is required. After combustion, the hot gases are to be evacuated from furnace through the heat absorbing surfaces. This air and gas flow is created by the boiler draught system, which may be either natural or mechanised. The air drawn from the atmosphere is first routed through an air heater where air is heated by the outgoing flue gases. The hot air is then admitted to the furnace through wind box. In coal fired boilers part of this hot air is used for drying the coal in the pulvariser and transporting the pulvarised coal to furnace. The gases pass through the radiant heat release zone and then through various superheaters and reheaters (in reheat boilers). Normally there will be a primary superheater and secondary superheater.
  • 11. After passing through the air heater the flue gas goes to the chimney. In between the air heater and chimney it is customary to provide precipitator to remove the flyash from the flue gas (especially in coal fired boilers) and induced draught fans to suck out the flue gases from the furnace (in balanced draught/induced draught boilers). water is the working medium which transfers the heat energy available in the fuel to the turbine in the form of steam. 22° C reduction in flue gas temperature increases boiler efficiency by 1%
  • 12. Water is chosen as the medium because of the following reasons. a) its easy availability b) its low viscous property c) it has high specific heat d) Its non-reactivity with surfaces with which it comes in to contact.
  • 13. The following can be termed as boiler pressure parts. 1. Boiler drum 2. Water walls 3. Superheaters 4. Reheaters and 5. Economisers
  • 14. BOTTOM RNG HDR& Z-PANEL 1ST PASS W.W 1ST PASS W.W O/L HDRS ROOF I/L HEADER 2ND PASS UPPER C-HDR 2nd PASS LOWER C-HDRS LTSH I/L HEADER LTSH O/L HEADER D.P.I/L HEADER D.P.O/L HEADER S.H. HEADER R.H.HEADER 2ND PASS ROOF O/L HDR(REAR ECONOMISER M.S H. R. HC.R.H FROM F.R.S
  • 15. Steam Generator Bottom Ash Hopper Bottom Ring Header Economiser LTSH Eco Hopper Drum Final SH Furnace ReheaterPlaten SH Front Pass Rear Pass Goose Neck Water Walls Pent House Steam cooled Walls Air Pre Heater Wind Box Burners
  • 16.
  • 18. BOILER DRUM The drum acts as reservoir for water & saturated steam and also provides separation and purification of steam. The feed water to the drum reaches the drum from the boiler feed pump via the economizer. A stronger material for use in boiler drums is Ducal W30.
  • 19. Methods of Steam Separation: 1. By Gravity separation This is employed for boilers having low generation rates. 2. By use of Baffles These are in the form of obstacles in the direct path of steam towards outlet.
  • 20. WATER WALL SYSTEM: In the boiler the walls of the combustion chamber are formed by tubular wall sections which not only form the enclosure for the furnace but also provides the evaporating surface for the feed water. The water from the boiler drum is admitted in to the water wall tubes through the downcomers and bottom ring headers. As the water circulates through the waterwall tubes, which receive heat from the furnace radiation, water partially evaporates into steam. Water-steam mixture then return back to the boiler drum.
  • 21. SUPER HEATERS: Super heaters (SH) are meant for raising the steam temperature above the saturation temperature. The superheated and reheated steam temperature around 540°C and pressure 165 bar. i) SH (Reheater also) can classified into convection and radiation type as per heat transfer process. The super heaters and reheaters which are placed above the furnace and can view the flame are called radiant type. ii) Super heater may be classified also according to the shape of the tube banks and the position of the headers, such as pendant SH, platen SH, horizontal SH, Ceiling SH, wall SH etc. iii) They may be classified according to their stages of superheating they perform, like primary SH, Secondary SH, Final SH etc.
  • 22. Reheaters: Reheaters (RH) are provided to raise the temperature of the steam from which part of energy has already been extracted by HP turbine.
  • 23. De-superheaters: Though super heaters are designed in such a way that heat absorbed by radiant and convection super heaters always try to maintain the steam temperature constant in practice the necessary control is achieved by using de-super heater. All modern boiler contact type de-super heaters by which feed water are sprayed directly into the steam for required cooling. Amount of feed water to be sprayed is controlled by automatic control system which is designed to maintain a set final steam temperature. Provision of manual control is also there for emergency.
  • 24. ECONOMISERS: The economiser absorbs heat from the flue gas and adds it mainly as sensible heat to the feed water. The material used in the manufacture of furnace wall tubes for coal fired boiler is ordinary carbon steel but in the 500 MW oil fired units the major proportion of the furnace is constructed from the 1% Cr. ½% Mo Alloy. In 660 MW units also this material is used for whole of the furnace.
  • 25. The Boiler Auxiliaries : • Draft system • Air heaters •Milling systems •Electrostatic precipitators, etc.
  • 26. DRAFT SYSTEM: • The combustion process in a furnace can take place only when it receives a steady flow of Air and has the combustion gases continuously removed. • The Boiler draft system includes Air and Flue gas flow. • All modern large utility boilers are fired under "balanced draft" condition, i.e. where draft is zero. This condition is created by the combination of "forced draft" and "Induced draft".
  • 27. SOOT BLOWERS • deposits resulting from the combustion of coal will be deposited on the boiler tubes at various zones will be cleaned by soot blowing for effective heat transfer while on-load. AIR HEATERS: • The air heater is required for efficient combustion in the furnace and also for drying wet coal in the milling plant. to recover "waste" heat from the flue gas to increase boiler efficiency
  • 29. MILLING PLANT : • raw coal from the bunker is fed at a regulated rate to the mills through a feeder. • Air required for drying and transporting the pulverized coal from the mill is obtained from the FD fan. • Hot air is drawn through air heaters and cold air directly from FD fan discharge. • The drying and grinding takes place inside the mills. The pulverized particles are being carried from the mill to the classifier, which is directly mounted on the mill. • The medium is directed into the burners through various fuel pipelines.
  • 30. Type of Pulverizers: Drum/Tube mills: Ball mills: Bowl mills:
  • 31. ELECTROSTATIC PRECIPITATORS: Working Principle: • The principles upon which an electrostatic precipitator operates are that the dust laden gases pass into a chamber where the individual particles of dust are given an electric charge by absorption of free ions from a high voltage D.C. ionising field. • They are removed by an intermittent blow usually referred to as rapping. This causes the dust particles to drop into dust hoppers situated below the collecting electrodes.
  • 32. The following fans are used in the boiler houses: 1. Forced Draft fan (F.D. Fan): To take air from atmosphere to supply all the Combustion air. Speeds vary between 600 to 1500 r.p.m. 2. Induced Draft Fan (I.D. Fan): Used only in balanced draft units to suck the gases out of the furnace and throw them into the stack. Handles flue gases at temperatures of 125 to 200o C. Speed generally does not exceed 1000 rpm. 3. Primary Air Fans (P.A. Fans) or Exhauster Fan: Used for pulverized system Primary air has got two functions viz. Drying the coal and transportation into the furnace. Usually 1500 r.p.m.
  • 34. Steam Turbine • As mentioned before, something has to turn the rotor in order to generate electricity. • In our case the prime mover happens to be a steam turbine. • Steam comes out of the tubes in the boiler and into a manifold then into the turbine. • As the steam passes over the turbine blades, torque is produced as a result of the blade shape.
  • 37. Steam Turbine • The rate of steam flow controls how fast the turbine rotates and therefore the frequency of the electricity produced. • As the steam moves through the turbine energy is extracted which results in a pressure drop. • Therefore the LP turbine is located at the exit of the HP turbine to extract the maximum amount of energy from the steam before it is sent to the condenser. • As electricity is generated it leaves the building though a very large circuit breaker and a series of transformers before it enters the power grid.
  • 40. Condenser • After the steam leaves the LP turbine it travels to the condenser, where it is condensed back to liquid water. • The condenser is a heat exchanger that cools the steam while is passes over tubes that have cold water running through them. • The cold water removes energy from the heated steam causing it to condense which is necessary for the water to be re-used as feed. • There is another reason why the condenser is necessary which we will discuss shortly.
  • 41. Cooling Towers • The water that runs through the tubes in the condenser must be cooled down in order to condense the steam. • This is accomplished using very large cooling towers, in which the water is atomized by sprayers and cooled down by atmospheric conditions and fans. • The substance leaving cooling towers is sometimes mistaken for smoke, but it is in fact just water vapor.
  • 45. Feed System • After the condensate is collected in the hotwell of the condenser it is pumped through the feed system. • The feed pump increases the pressure of the feed water in order for it to flow back into the boiler to be turned back into steam to start the cycle over again. • This stage turns out to be the 4th and final stage of something called a heat engine.
  • 47. Laws of Thermodynamics • 1st : “The increase in internal energy of a system is equal to the amount of heat energy added to the system minus the work done by the system on the surroundings.”
  • 48. Laws of Thermodynamics • 2nd : The temperature differences between systems in contact with each other tend to even out and that work can be obtained from these non-equilibrium differences, but that loss of heat occurs, in the form of entropy, when work is done. • 2nd : It is impossible to produce work in the surroundings using a cyclic process connected to a single heat reservoir (Kelvin, 1851).
  • 49. Laws of Thermodynamics • The second law also states that the maximum efficiency of a heat engine can be determined by: η = 1-(Th/Tc) • Efficiency is also equal to the work output over the heat input. η = Δ W/Δ QH
  • 50. Efficiency • An ordinary power plant operates between the temperatures of 565C and 25C which leads to maximum efficiency of around 64%. • However, due to the losses mentioned earlier the usual observed efficiency is about 35%. • This shows how much of the energy stored in the coal is just wasted instead of being converted to electricity.
  • 51. Steam Cycle • The previous part of the presentation was to explain the process behind electricity generation that occurs after the coal portion. • I will now go through some of the components dealing with the coal aspect of the power plant ending at the boiler which is where the steam cycle began. • Most of what I will discuss is particular to the Co-gen plant that I visited.
  • 52. Coal Delivery • After the coal is mined and loaded into trucks it is delivered into chutes that lead to the Bradford Breaker. • The breaker is a drum with hammers in it that rotates and breaks the coal down into pieces about 4” diameter, which fall through the screen and onto the conveyor belt which leads to the storage facility.
  • 55. Coal Storage • After the coal has been sufficiently reduced in size, it enters a storage facility, in this case, a large dome. • The coal is then stacked using a machine you will see in the next slide, which rotates and places the coal around the perimeter of the dome. • This same machine also takes coal from the pile and delivers it to the crusher building.
  • 57. Crusher • The coal is delivered from the storage facility to a device conveniently called a coal crusher. • This machine takes the 4” pieces of coal and through a series of rollers converts the fuel into a fine powder. • This powder is necessary for proper combustion in the boilers. • All newer state of the art power plants are set up to work with pulverized coal, but older plants may operate with lumped coal.
  • 60. Fuel Feed System • The conveyor belt delivers the crushed coal to a series of fuel feeders, which inject coal into the boilers along with a mixture of high pressure air for combustion.
  • 63. Boilers • The final stage for the coal coincides with the first stage of the steam plant. • The boiler is usually the largest component of the coal power plant climbing as high as 200 ft. • Inside the boilers the pulverized coal is burned while it more or less floats with the aid of HP air. • Lining the entire inside of the boiler are tubes which carry the feed water to be turned into steam.
  • 67. After the Boiler • As the coal is burned a large amount of ash is produced. • Some falls to the bottom and is collected, then mixed with water and sent to the ash pile. • Very light ash particles also escape with the exhaust gasses which are captured by a bag filter system. • This fly ash is collected in a silo until a certain level is reached when it is pumped to the ash pile via HP air.
  • 70. Ash • This ash has a basic pH and has some beneficial uses. • After a truck delivers coal to the plant it is filled with ash to return to the reclamation site. • The high pH helps treat acid mine drainage.
  • 71. Ash • The fly ash is used as a substitute to make Portland cement. • Another use of fly ash is structural fill for highway embankments and the fill under new highways.
  • 72. Exhaust Gasses and the Stack • One of the most controversial aspects of a coal power plant is what comes out of the stack. • During the combustion process dangerous gasses and particulates are released, such as NOx, SOx, and CO2. • Controls are in effect for each of these in new plants, however older plants spew thousands of pounds of each of these into the atmosphere every year.
  • 73. Intermittent Blowdown • The intermittent blown down is given by manually operating a valve fitted to discharge pipe at the lowest point of boiler shell to reduce parameters (TDS or conductivity, pH, Silica etc) within prescribed limits so that steam quality is not likely to be affected • TDS level keeps varying • fluctuations of the water level in the boiler. • substantial amount of heat energy is lost with intermittent blow down.
  • 74. Continuous Blowdown • A steady and constant dispatch of small stream of concentrated boiler water, and replacement by steady and constant inflow of feed water. • This ensures constant TDS and steam purity. • This type of blow down is common in high- pressure boilers.
  • 75. Boiler Water Treatment • Internal Water Treatment: It is carried out by adding chemicals to boiler to prevent the formation of scale by converting the scale-forming compounds to free-flowing sludges, which can be removed by blowdown. • Limitation: Applicable to boilers, where feed water is low in hardness salts, to low pressures- high TDS content in boiler water is tolerated, and when only small quantity of water is required to be treated. • Internal treatment alone is not recommended.
  • 76. External Water Treatment • Propose: External treatment is used to remove suspended solids, dissolved solids (particularly the calcium and magnesium ions which are a major cause of scale formation) and dissolved gases (oxygen and carbon dioxide). • Different treatment Process : – ion exchange; – demineralization; – reverse osmosis and – de-aeration.
  • 77. Demineralization • Demineralization is the complete removal of all salts. • This is achieved by using a “cation” resin, which exchanges the cations in the raw water with hydrogen ions, producing hydrochloric, sulphuric and carbonic acid. • Carbonic acid is removed in degassing tower in which air is blown through the acid water. • Following this, the water passes through an “anion” resin which exchanges anions with the mineral acid (e.g. sulphuric acid) and forms water. • Regeneration of cations and anions is necessary at intervals using, typically, mineral acid and caustic soda respectively. The complete removal of silica can be achieved by correct choice of anion resin.
  • 78. De-aeration • When heated in boiler systems, carbon dioxide (CO2 ) and oxygen (O2 ) are released as gases and combine with water (H2 O) to form carbonic acid, (H2 CO3 ). Deaerator •In de-aeration, dissolved gases, such as oxygen and carbon dioxide, are expelled by preheating the feed water before it enters the boiler.
  • 79. Exhaust Gasses and the Stack
  • 81. Reduce Stack Temperature • Stack temperatures greater than 200°C indicates potential for recovery of waste heat. • It also indicate the scaling of heat transfer/recovery equipment and hence the urgency of taking an early shut down for water / flue side cleaning. 22o C reduction in flue gas temperature increases boiler efficiency by 1%

Notas do Editor

  1. Notice the wires on the right side
  2. Notice the tubes running on the inside.
  3. Just a fancy way of saying that for work to be done the working fluid must pass from a high temp reservoir to a low temp reservoir. Energy is lost as this waste energy and also to entropy, which increases with any work process.
  4. Fly ash, Limestone for SOx and Ammonia for NOx