SlideShare uma empresa Scribd logo
1 de 8
Baixar para ler offline
Purdue University

Purdue e-Pubs
International Refrigeration and Air Conditioning
Conference

School of Mechanical Engineering

2006

Reducing AC Power Consumption By
Compressor Downsizing on a Sports Utility
Vehicle
D. Srinivasan
Tata Motors Ltd.

Prasad Phadke
Tata Motors Ltd.

Follow this and additional works at: http://docs.lib.purdue.edu/iracc
Srinivasan, D. and Phadke, Prasad, "Reducing AC Power Consumption By Compressor Downsizing on a Sports Utility Vehicle"
(2006). International Refrigeration and Air Conditioning Conference. Paper 844.
http://docs.lib.purdue.edu/iracc/844

This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for
additional information.
Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/
Herrick/Events/orderlit.html
R048, Page 1

REDUCING AC POWER CONSUMPTION BY COMPRESSOR
DOWNSIZING ON A SPORTS UTILITY VEHICLE
D Srinivasan*, Prasad Phadke
Climate Control Group, Engineering Research Centre, TATA Motors Ltd.
Pune – 411018, Maharashtra, India.
Tel: +91-20-56133226, Fax: +91-20-56131960
*Corresponding author
Email: d.srinivasan@tatamotors.com
ABSTRACT
Reducing AC power consumption in an automobile is one of the key challenges for climate control engineers. The
AC compressor consumes power from the engine which directly affects fuel economy and vehicle drivability. The
main objective of this study is to reduce front end auxiliary drive (FEAD) load on engine by compressor
downsizing, without compromising on cooling performance of the AC system. The study has been carried out on a
sports utility vehicle (SUV) which has twin evaporator AC system. The three compressors under study have been
critically evaluated at three levels a) Component level b) System level and c) Vehicle level. The study has been
conducted in two phases 1) downsizing from 170 cc/rev reciprocating piston compressor to 130 cc/rev compressor
and 2) further downsizing from 130 cc/rev reciprocating piston compressor to 90 cc/rev rotary scroll compressor.
The results of this study demonstrate that AC power consumption and refrigerant quantity are reduced by 25% and
5% respectively.
Key words: Automobile climate control, front end auxiliary drive load, power consumption, compressor
downsizing.

1. INTRODUCTION
One of the primary functions of an automobile climate control system is to provide the desired cooling and stabilise
cabin temperatures to comfortable levels in hot climatic conditions. With the increasing demand for more energy
efficient systems and thermal comfort in automobiles, the automobile AC system needs to be optimized to deliver
the required cooling performance with minimum AC power consumption. Proper selection and integration of AC
compressor with other system aggregates results in improved energy efficiency of the system.
Geon and Tae (2004) have mentioned about the importance of AC power consumption reduction in their study.
Urchueguia et al. (2003) have carried out experiments with scroll and reciprocating compressors using R22 and
propane as refrigerant, for a commercial type refrigeration unit of nominal capacity of about 20kW. Kapoor et al.
(2004) have carried out experiments with reciprocating and scroll compressors on a small car automotive air
conditioning system and found that 60 cc/rev scroll compressor delivers an equivalent cooling with 20% reduction
in power consumption as compared to a 110 cc/rev reciprocating piston compressor. Perevozchikov and Pham
(2004) have shown that variable speed scroll compressor gives superior performance over conventional compressors
in terms of efficiency and reliability.
The SUV considered for this study is originally equipped with 170 cc/rev reciprocating piston compressor. The
study of various compressors shows that for the same application, a smaller capacity compressor can be used to
reduce AC power consumption and still can maintain the same level of cooling by optimizing the AC system
aggregates. In addition, by deploying scroll compressor technology, the compressor capacity can be further
downsized, making the system even more energy efficient.
In case of conventional reciprocating piston type swash plate compressors, frictional losses are high due to the
reciprocating motion of pistons past the walls of the cylinders, resulting in lower efficiencies. In case of a scroll
compressor, its typical internal construction and compression mechanism reduces the frictional losses and increases

International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
R048, Page 2
the efficiency. In a scroll compressor, there are two spiral-shaped scroll members, one stationary scroll and the other
scroll orbiting relative to the stationary scroll. These two members fit together forming crescent shaped pockets. As
the orbiting motion continues, refrigerant is drawn in from the outer ends and forced toward the center of the scroll
form gradually increasing refrigerant pressure. The high pressure refrigerant is then discharged from the center port
of the fixed scroll member.

2. METHODOLOGY
The methodology adopted for this study is to experimentally evaluate the power consumption and cooling
performance of the three AC compressors under study at three different levels a) component level calorimetric test
b) system level bench test and c) vehicle level dynamometer test. This study has been carried out in two distinct
phases.

2.1 Phase 1:
In phase 1, 170 cc/rev reciprocating piston compressor is compared with 130 cc/rev reciprocating piston compressor.
Both these compressors have similar technology and are similar in construction. For 130 cc/rev compressor, the AC
system has been reconfigured with change in capacity of thermostatic expansion valve and refrigerant charge
quantity as compared to the existing AC system.

2.2 Phase 2:
In phase 2, 130 cc/rev reciprocating piston compressor is compared with 90 cc/rev rotary scroll compressor. These
two compressors are different in both, technology and construction. There is no change in the system configuration
and refrigerant charge quantity for these two compressors.

3. TEST CONDITIONS
3.1 Compressor Calorimetric Test
All the three compressors under study are tested as stand alone on a compressor calorimeter, under identical test
conditions (LP=1.76 bar, HP=16.4 bar, SH=10°C, SC=5°C). The set points represent the typical vehicle operating
conditions. The compressor cooling capacity and power consumption are evaluated at four different engine speeds.

3.2 System level Bench Test
The experimental set up consisted of original components from the R134a system of a typical twin evaporator AC
system of SUV. The set up as shown in Figure 1 consists of three environmental chambers for the compressor,
condenser and evaporator. The compressor drive motor is housed in a fourth chamber.

Evaporator 2
(roof mount)

Evaporator 1
(underdash)

Condenser

Compressor
Motor
Evaporator Room

Condenser Room

Compressor Room
Figure 1: Schematic diagram for Bench test set up
The compressor chamber holds the compressor at a desired temperature to simulate temperature conditions in the
engine compartment of the car. The compressor is run by the electrical motor acted upon by frequency converter in
order to cover the whole range of rotational speed in the actual vehicle. Condenser and evaporator chambers contain

International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
R048, Page 3
a wind tunnel with variable speed blower and temperature controller, enabling a wide range of air flow rates and
temperatures for the condenser and evaporator chambers respectively. The evaporator chamber also has a steam
supply and humidity controller to provide latent heat load. In addition the evaporators are kept in the original plastic
casing to preserve the same air circuit and flow rate as in the actual vehicle.
The test condition is designed to represent actual vehicle operating conditions. On the test bench, the compressor
speeds for all three compressors were set corresponding to engine speed as on the vehicle. There are five engine
speeds from 950 rpm to 4000 rpm simulating vehicle idling to high cruising speeds. The ambient air around the
compressor is maintained at 100°C and the condenser at 45°C. Air flow rate across the condenser is related to
vehicle speed. In stationary idling condition, the velocity is restricted to 1 m/s whereas at cruising speed of 80 kmph,
the velocity is set to 4.5 m/s. The inlet air condition for the evaporator is 35°C / 60% RH. Air flow rate set over
evaporator 1 is 400 m3/hr and over evaporator 2 is 180 m3/hr. These typically are the air flow rates at the maximum
blower speed for a twin evaporator AC system of SUV. In the bench test, cooling capacity and power consumption
of the AC compressor at the system level has been evaluated across engine speeds.

3.3 Vehicle level dynamometer Test
The SUV is tested on a chassis dynamometer with the three compressors. The tests are conducted under identical
test conditions to evaluate the AC power consumption. The tests are done at five vehicle speeds in 5th gear full
throttle condition. To ensure that the AC system is fully loaded and the compressor works continuously during the
test, the windows are kept open and the anti-icing device is bypassed.

4. EXPERIMENTAL RESULTS
4.1 Phase 1: 170 cc/rev compressor (reciprocating) vs. 130 cc/rev compressor (reciprocating)
4.1.1 Compressor Calorimetric Test: Figure 2 shows comparative performance of the two compressors in the
compressor calorimeter. The power consumption of 130 cc/rev compressor is 5% to 18% lesser than 170 cc/rev
compressor across engine speeds. The result also demonstrates that cooling capacity of 130 cc/rev compressor is
lesser by 13% to 24% than 170 cc/rev compressor as stand alone component.
170 cc/rev (reciprocating)

130 cc/rev (reciprocating)

Cooling capacity & Power consumption (kW)

10.0
9.0

Test conditions
LP = 1.76 bar
HP = 16.4 bar
SH = 10°C
SC = 5°C

8.0
7.0

Cooling capacity

6.0
5.0
4.0

Power consumption

3.0
2.0
1.0
0.0
0

500

1000

1500

2000

2500

3000

3500

4000

4500

Engine speed (rpm)

Figure 2: Compressor calorimetric test – 170 cc/rev vs 130 cc/rev
4.1.2 System Bench test: Figure 3 shows the bench level performance of the two compressors. The result
demonstrates that power consumption of 130 cc/rev compressor is lower by 1% to 9% below 2500 rpm and higher
by 2% to 5% above 2500 rpm compared to 170 cc/rev compressor. The combined cooling capacity of the twin
evaporator system with 130 cc/rev compressor is lower by 3% compared to 170cc/rev compressor below 1750 rpm
and higher by 2% above 1750 rpm.

International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
R048, Page 4

170 cc/rev (reciprocating)

130 cc/rev (reciprocating)

Cooling capacity & Power consumption (kW)

7.00

6.00

Cooling capacity

5.00

Power consumption
4.00

3.00

2.00

1.00

0.00
0

500

1000

1500

2000

2500

3000

3500

4000

4500

Engine speed (rpm)

Figure 3: Bench test – 170 cc/rev vs 130 cc/rev
By optimising the capacity of thermostatic expansion valve and refrigerant charge quantity, the 130cc/rev
compressor when coupled with other AC system aggregates delivers the same cooling performance as 170 cc/rev
compressor with less power consumption. This demonstrates that 130 cc/rev compressor is better optimised with the
other AC system aggregates.
The refrigerant charge quantity for the twin evaporator system with 130 cc/rev compressor is reduced from existing
950 gms to 900 gms.
The 170 cc/rev compressor, which delivers higher cooling capacity at component level (stand alone), delivers lower
cooling performance when coupled with other AC system aggregates. This demonstrates that 170 cc/rev compressor
is overcapacity for the existing AC system.
4.1.3 Vehicle level dynamometer test: Figure 4 shows the AC system power consumption across vehicles speeds
with 170 cc/rev compressor and 130 cc/rev compressor. Test results demonstrate that 130 cc/rev compressor
consumes 8% to 15% lesser power compared to 170 cc/rev compressor. This reduction in power consumption is
achieved with the same level of cooling performance.
170 cc/rev compressor

130 cc/rev compressor

4

AC power consumption (kW)

3.5
3
2.5
2
1.5
1
0.5
0
30

40

45

55

75

Vehicle speed (Kmph)

Figure 4: Chassis dynamometer test – 170 cc/rev vs 130 cc/rev

International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
R048, Page 5
At the end of phase 1, the test results demonstrate that at all three levels 130 cc/rev compressor consumes lesser
power as compared to 170cc/rev compressor. The results also show that after optimising the AC system aggregates,
130 cc/rev compressor delivers same cooling performance as that of 170 cc/rev compressor. Based on these
advantages, 170 cc/rev reciprocating compressor has been replaced by 130 cc/rev reciprocating compressor on the
vehicle.

4.2 Phase 2: 130 cc/rev compressor (reciprocating) vs. 90 cc/rev compressor (scroll)
4.2.1 Compressor Calorimetric Test: Figure 5 shows comparative performance of the two compressors in the
compressor calorimeter. The power consumption of 90 cc/rev scroll compressor is 2% to 13% lower than 130 cc/rev
reciprocating compressor across engine speeds. The result also demonstrates that cooling performance of scroll
compressor is 4% to 30% higher than reciprocating compressor as stand alone component. The performance curves
for 170 cc/rev compressor are shown with dotted lines for reference.
170 cc/rev (reciprocating)

130 cc/rev (reciprocating)

90 cc/rev (scroll)

12.0

Cooling capacity & Power consumption (kW)

11.0

Test conditions
LP = 1.76 bar
HP = 16.4 bar
SH = 10°C
SC = 5°C

10.0
9.0

Cooling capacity

8.0
7.0
6.0
5.0
4.0

Power consumption

3.0
2.0
1.0
0.0
0

500

1000

1500

2000

2500

3000

3500

4000

4500

Engine speed (rpm)

Figure 5: Compressor calorimetric test – 130 cc/rev vs 90 cc/rev
4.2.2 System Bench Test: Figure 6 shows the bench level performance of 130 cc/rev reciprocating and 90 cc/rev
scroll compressor. The power consumption of scroll compressor is lower by 5% to 20% compared to reciprocating
170 cc/rev (reciprocating)

130 cc/rev (reciprocating)

90 cc/rev (scroll)

Cooling capacity & Power consumption (kW)

8.00

7.00

Cooling capacity
6.00

5.00

Power consumption
4.00

3.00

2.00

1.00

0.00
0

500

1000

1500

2000

2500

3000

3500

4000

4500

Engine speed (rpm)

Figure 6: Bench test – 130 cc/rev vs 90 cc/rev

International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
R048, Page 6
compressor below 2400 engine rpm. The combined cooling performance of twin evaporator system with 90 cc/rev
scroll compressor is higher by 4% to 12% compared to 130 cc/rev reciprocating compressor across engine speeds.
Without making any modifications in the system and with same refrigerant charge quantity (900 gms) as that of
reciprocating compressor, the scroll compressor delivers more cooling performance with less power consumption.
The scroll compressor which delivers higher cooling performance at component level (stand alone), once again
demonstrates higher cooling performance when coupled with other AC system aggregates at bench level. This
shows that scroll compressor is well optimised with AC system aggregates. The performance curves for 170 cc/rev
compressor are shown with dotted lines for reference.
4.2.3 Vehicle level dynamometer test: Figure 7 shows the AC system power consumption across vehicles speeds
with 130 cc/rev reciprocating compressor and 90 cc/rev scroll compressor. Test results demonstrate that scroll
compressor consumes 16% to 25% lesser power compared to reciprocating compressor. This reduction in power
consumption is achieved with the same level of cooling performance. The values for 170 cc/rev reciprocating
compressor are also captured for reference.
170 cc/rev (reciprocating)

130 cc/rev compressor (reciprocating)

90 cc/rev (scroll)

4

AC power consumption (kW)

3.5

3

2.5

2

1.5

1

0.5

0
30

40

45

55

75

Vehicle speed (Kmph)

Figure 7: Chassis dynamometer test – 130 cc/rev vs 90 cc/rev
At the end of phase 2, the test results demonstrate that at all three levels 90 cc/rev scroll compressor consumes lesser
power compared to 130 cc/rev reciprocating compressor. It also shows that 90 cc/rev scroll compressor delivers
higher cooling performance than that of 130 cc/rev reciprocating compressor with no change in the AC system
aggregates. Based on these advantages, 90 cc/rev scroll compressor has been recommended to replace 130 cc/rev
reciprocating compressor.

5. CONCLUSIONS
The main focus of the present study is reduction in the AC power consumption by compressor downsizing. A
methodical approach of three way experimental evaluation in two phases has been followed to realize the objective.
• In phase 1, by downsizing the AC compressor from 170 cc/rev to 130 cc/rev capacity, 8% to 15% reduction in
power consumption is achieved.
• In phase 2, by downsizing the AC compressor from 130 cc/rev to 90 cc/rev capacity, 16% to 25% reduction in
power consumption is achieved.
• Overall, there is 24% to 30% reduction in AC power consumption by replacing 170 cc/rev reciprocating
compressor with 90 cc/rev scroll compressor. The lower power consumption of scroll compressor can be
attributed solely to its internal construction, compression mechanism, and lower frictional losses.
• Furthermore, there is 5% reduction in refrigerant charge quantity because of compressor downsizing.
All these benefits are achieved without any deterioration in the AC cooling performance. The scroll compressor
offers the added benefits of low noise, higher continuous speeds and improved drivability. Advancements in

International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
R048, Page 7
compressor technology offer opportunities to further reduce the AC power consumption and refrigerant charge
quantity.

ABBREVIATIONS
HP
LP
RH
SC
SH
AC

High pressure
Low pressure
Relative Humidity
Sub cooling
Superheating
Air conditioning

REFERENCES
Geon Lee, Tae Lee, 2004, A study on the variable displacement mechanism of swash plate type compressor for
automotive air conditioning system, Int. Compressor Engineering Conference at Purdue: C079
Urchueguia Javier F., Jose Miguel Corberan, Jose Gonzalvez, Jose Miguel Diaz, 2003, Experimental
characterization of a commercial size scroll and reciprocating compressor working with R22 and propane (R290) as
refrigerant. Int. Congress of Refrig., Washington DC, Session B2–1, p. 1–8
Kapoor S.H., Paramane S., Dr Arora G., 2004, Application of energy efficient scroll compressor for small cars, Int.
Refrigeration and Air conditioning Conference at Purdue: R060
Perevozchikov M.M., Pham H.M., 2004, Scroll compressor for mobile HVAC/R application, Int. Compressor
Engineering Conference at Purdue: C095

ACKNOWLEDGEMENT
The authors gratefully acknowledge the support provided to this work by Tata Motors Ltd, Pune, India. The authors
also acknowledge the guidance and support given by Mr. Hirak Mukherjee from MHI, India.

International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006

Mais conteúdo relacionado

Mais procurados

CFD Analysis of C. I. Engine Cooling Water Pump of car
CFD Analysis of C. I. Engine Cooling Water Pump of carCFD Analysis of C. I. Engine Cooling Water Pump of car
CFD Analysis of C. I. Engine Cooling Water Pump of carijsrd.com
 
Combined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser SystemsCombined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser SystemsIRJET Journal
 
Hrsg startup proceudre
Hrsg startup proceudreHrsg startup proceudre
Hrsg startup proceudrekamaraprasad
 
IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...
IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...
IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...Husain Mehdi
 
EJECTOR EXPANSION REFRIGERATION SYSTEM
EJECTOR EXPANSION REFRIGERATION SYSTEMEJECTOR EXPANSION REFRIGERATION SYSTEM
EJECTOR EXPANSION REFRIGERATION SYSTEMsijo k k
 
Compressed air sourcebook (2)
Compressed air sourcebook (2)Compressed air sourcebook (2)
Compressed air sourcebook (2)mohamadans
 
Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...
Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...
Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...Guofu Chen
 
cfd analysis on ejector cooling system with variable throat geometry
 cfd analysis on ejector cooling system with variable throat geometry cfd analysis on ejector cooling system with variable throat geometry
cfd analysis on ejector cooling system with variable throat geometryIjripublishers Ijri
 
Cooling of a truck cabin by vapour absorption refrigeration system using engi...
Cooling of a truck cabin by vapour absorption refrigeration system using engi...Cooling of a truck cabin by vapour absorption refrigeration system using engi...
Cooling of a truck cabin by vapour absorption refrigeration system using engi...eSAT Publishing House
 
Energy conservation in compressed air systems
Energy conservation in compressed air systemsEnergy conservation in compressed air systems
Energy conservation in compressed air systemsVishnu RC Vijayan
 
Fan and blowers (mech 326)
Fan and blowers (mech 326)Fan and blowers (mech 326)
Fan and blowers (mech 326)Yuri Melliza
 
Compressed air and refrigeration system
Compressed air and refrigeration systemCompressed air and refrigeration system
Compressed air and refrigeration systemD.Pawan Kumar
 
Energy Conservation in Compressed Air System.
Energy Conservation in Compressed Air System.Energy Conservation in Compressed Air System.
Energy Conservation in Compressed Air System.AffanDabir
 
Methods to improve performance of compressed air system
Methods  to  improve  performance  of  compressed  air  systemMethods  to  improve  performance  of  compressed  air  system
Methods to improve performance of compressed air systemRaveen Ramanan
 
An ejector refrigeration cycle
An ejector refrigeration cycleAn ejector refrigeration cycle
An ejector refrigeration cyclexueyuejingling
 
Aircraft cabin pressurization system
Aircraft cabin pressurization systemAircraft cabin pressurization system
Aircraft cabin pressurization systemShrinivas Kale
 
Air compressor overview and basic selection guide
Air compressor overview and basic selection guideAir compressor overview and basic selection guide
Air compressor overview and basic selection guideAnilkumar B Nair
 
Ejector Expansion Refrigeration Systems
Ejector Expansion Refrigeration SystemsEjector Expansion Refrigeration Systems
Ejector Expansion Refrigeration Systemsinventy
 
Energy efficiency improvement opportunities in compressed air systems
Energy efficiency improvement opportunities in compressed air systemsEnergy efficiency improvement opportunities in compressed air systems
Energy efficiency improvement opportunities in compressed air systemsPratik Bhoir
 

Mais procurados (20)

CFD Analysis of C. I. Engine Cooling Water Pump of car
CFD Analysis of C. I. Engine Cooling Water Pump of carCFD Analysis of C. I. Engine Cooling Water Pump of car
CFD Analysis of C. I. Engine Cooling Water Pump of car
 
Combined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser SystemsCombined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser Systems
 
Hrsg startup proceudre
Hrsg startup proceudreHrsg startup proceudre
Hrsg startup proceudre
 
IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...
IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...
IJREI_A thermodynamic analysis of ejector type vapour refrigeration system us...
 
dst2
dst2dst2
dst2
 
EJECTOR EXPANSION REFRIGERATION SYSTEM
EJECTOR EXPANSION REFRIGERATION SYSTEMEJECTOR EXPANSION REFRIGERATION SYSTEM
EJECTOR EXPANSION REFRIGERATION SYSTEM
 
Compressed air sourcebook (2)
Compressed air sourcebook (2)Compressed air sourcebook (2)
Compressed air sourcebook (2)
 
Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...
Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...
Guofu_Chen_Optimize Design and Operation of Renewable Energy Cycle through As...
 
cfd analysis on ejector cooling system with variable throat geometry
 cfd analysis on ejector cooling system with variable throat geometry cfd analysis on ejector cooling system with variable throat geometry
cfd analysis on ejector cooling system with variable throat geometry
 
Cooling of a truck cabin by vapour absorption refrigeration system using engi...
Cooling of a truck cabin by vapour absorption refrigeration system using engi...Cooling of a truck cabin by vapour absorption refrigeration system using engi...
Cooling of a truck cabin by vapour absorption refrigeration system using engi...
 
Energy conservation in compressed air systems
Energy conservation in compressed air systemsEnergy conservation in compressed air systems
Energy conservation in compressed air systems
 
Fan and blowers (mech 326)
Fan and blowers (mech 326)Fan and blowers (mech 326)
Fan and blowers (mech 326)
 
Compressed air and refrigeration system
Compressed air and refrigeration systemCompressed air and refrigeration system
Compressed air and refrigeration system
 
Energy Conservation in Compressed Air System.
Energy Conservation in Compressed Air System.Energy Conservation in Compressed Air System.
Energy Conservation in Compressed Air System.
 
Methods to improve performance of compressed air system
Methods  to  improve  performance  of  compressed  air  systemMethods  to  improve  performance  of  compressed  air  system
Methods to improve performance of compressed air system
 
An ejector refrigeration cycle
An ejector refrigeration cycleAn ejector refrigeration cycle
An ejector refrigeration cycle
 
Aircraft cabin pressurization system
Aircraft cabin pressurization systemAircraft cabin pressurization system
Aircraft cabin pressurization system
 
Air compressor overview and basic selection guide
Air compressor overview and basic selection guideAir compressor overview and basic selection guide
Air compressor overview and basic selection guide
 
Ejector Expansion Refrigeration Systems
Ejector Expansion Refrigeration SystemsEjector Expansion Refrigeration Systems
Ejector Expansion Refrigeration Systems
 
Energy efficiency improvement opportunities in compressed air systems
Energy efficiency improvement opportunities in compressed air systemsEnergy efficiency improvement opportunities in compressed air systems
Energy efficiency improvement opportunities in compressed air systems
 

Destaque

Solar Air Conditioner
Solar Air ConditionerSolar Air Conditioner
Solar Air Conditionernasa24
 
Solar Air Conditioner
Solar Air ConditionerSolar Air Conditioner
Solar Air Conditionerskullcrusher
 
Refrigeration and air conditioning ppt
Refrigeration and air conditioning pptRefrigeration and air conditioning ppt
Refrigeration and air conditioning pptShubham Hadadare
 
Air condition, Refrigeration Cycle, AC Cycle, Principles of AC, Applications
Air condition, Refrigeration Cycle, AC Cycle, Principles of AC, ApplicationsAir condition, Refrigeration Cycle, AC Cycle, Principles of AC, Applications
Air condition, Refrigeration Cycle, AC Cycle, Principles of AC, ApplicationsRakesh Kumar
 
Types of air conditioning systems
Types of air conditioning systemsTypes of air conditioning systems
Types of air conditioning systemsbecoolseo
 
Air conditioning-system ppt
Air conditioning-system pptAir conditioning-system ppt
Air conditioning-system pptIshtiaq Ahmad
 
Air Conditioning System
Air Conditioning SystemAir Conditioning System
Air Conditioning SystemSumit Ranjan
 
Complete hvac ppt by kk 354647.pptx 1234
Complete hvac ppt by kk 354647.pptx 1234Complete hvac ppt by kk 354647.pptx 1234
Complete hvac ppt by kk 354647.pptx 1234KRISHAN KUMAR
 
Refrigration & air conditioning
Refrigration & air conditioningRefrigration & air conditioning
Refrigration & air conditioningSiddharth Bedarker
 
Refrigeration And Air Conditioning
Refrigeration And Air ConditioningRefrigeration And Air Conditioning
Refrigeration And Air ConditioningSaurabh Jain
 
State of the Word 2011
State of the Word 2011State of the Word 2011
State of the Word 2011photomatt
 

Destaque (17)

Air Condition Repair
Air Condition RepairAir Condition Repair
Air Condition Repair
 
Air condition system
Air condition system Air condition system
Air condition system
 
Air condition system
Air condition system Air condition system
Air condition system
 
solar air conditioning
 solar air conditioning   solar air conditioning
solar air conditioning
 
Solar Air Conditioner
Solar Air ConditionerSolar Air Conditioner
Solar Air Conditioner
 
Solar Air Conditioner
Solar Air ConditionerSolar Air Conditioner
Solar Air Conditioner
 
Refrigeration and air conditioning ppt
Refrigeration and air conditioning pptRefrigeration and air conditioning ppt
Refrigeration and air conditioning ppt
 
Air condition, Refrigeration Cycle, AC Cycle, Principles of AC, Applications
Air condition, Refrigeration Cycle, AC Cycle, Principles of AC, ApplicationsAir condition, Refrigeration Cycle, AC Cycle, Principles of AC, Applications
Air condition, Refrigeration Cycle, AC Cycle, Principles of AC, Applications
 
Types of air conditioning systems
Types of air conditioning systemsTypes of air conditioning systems
Types of air conditioning systems
 
Air conditioning-system ppt
Air conditioning-system pptAir conditioning-system ppt
Air conditioning-system ppt
 
Air Conditioning System
Air Conditioning SystemAir Conditioning System
Air Conditioning System
 
Complete hvac ppt by kk 354647.pptx 1234
Complete hvac ppt by kk 354647.pptx 1234Complete hvac ppt by kk 354647.pptx 1234
Complete hvac ppt by kk 354647.pptx 1234
 
Refrigration & air conditioning
Refrigration & air conditioningRefrigration & air conditioning
Refrigration & air conditioning
 
Air conditioning system
Air conditioning systemAir conditioning system
Air conditioning system
 
Compressor
CompressorCompressor
Compressor
 
Refrigeration And Air Conditioning
Refrigeration And Air ConditioningRefrigeration And Air Conditioning
Refrigeration And Air Conditioning
 
State of the Word 2011
State of the Word 2011State of the Word 2011
State of the Word 2011
 

Semelhante a Reducing ac power consumption by compressor downsizing on a sport

ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...
ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...
ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...IAEME Publication
 
IRJET- A Review Paper on Air-Conditioner Works on Exhaust Gas
IRJET-  	  A Review Paper on Air-Conditioner Works on Exhaust GasIRJET-  	  A Review Paper on Air-Conditioner Works on Exhaust Gas
IRJET- A Review Paper on Air-Conditioner Works on Exhaust GasIRJET Journal
 
Compressors and compressed air systems
Compressors and compressed air systemsCompressors and compressed air systems
Compressors and compressed air systemsKantilal Malwania
 
Compressors and compressed air systems
Compressors and compressed air systemsCompressors and compressed air systems
Compressors and compressed air systemsthanhuce
 
Integrated Air Conditioning Unit for Automobiles
Integrated Air Conditioning Unit for AutomobilesIntegrated Air Conditioning Unit for Automobiles
Integrated Air Conditioning Unit for AutomobilesIJARTES
 
Performance Gain for Multiple Stage Centrifugal Compressor by usi.pdf
Performance Gain for Multiple Stage Centrifugal Compressor by usi.pdfPerformance Gain for Multiple Stage Centrifugal Compressor by usi.pdf
Performance Gain for Multiple Stage Centrifugal Compressor by usi.pdfbui thequan
 
PERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANT
PERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANTPERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANT
PERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANTIAEME Publication
 
Development of vapour absorption refrigeration system in vehicles
Development of vapour absorption refrigeration system in vehiclesDevelopment of vapour absorption refrigeration system in vehicles
Development of vapour absorption refrigeration system in vehiclesAshish Singh
 
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...IRJET Journal
 
78201906
7820190678201906
78201906IJRAT
 
78201906
7820190678201906
78201906IJRAT
 
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...Joel John
 
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...IRJET Journal
 
GAS TURBINE POWER PLANTS INLET AIR COOLING
GAS TURBINE POWER PLANTS INLET AIR COOLINGGAS TURBINE POWER PLANTS INLET AIR COOLING
GAS TURBINE POWER PLANTS INLET AIR COOLINGAhmed Abbas
 

Semelhante a Reducing ac power consumption by compressor downsizing on a sport (20)

ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...
ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...
ECO FRIENDLY AUTOMOBILE AIR-CONDITIONING UTILIZATION EXHAUST GAS WASTE HEAT O...
 
IRJET- A Review Paper on Air-Conditioner Works on Exhaust Gas
IRJET-  	  A Review Paper on Air-Conditioner Works on Exhaust GasIRJET-  	  A Review Paper on Air-Conditioner Works on Exhaust Gas
IRJET- A Review Paper on Air-Conditioner Works on Exhaust Gas
 
Compressors and compressed air systems
Compressors and compressed air systemsCompressors and compressed air systems
Compressors and compressed air systems
 
Compressors and compressed air systems
Compressors and compressed air systemsCompressors and compressed air systems
Compressors and compressed air systems
 
[IJET-V1I6P8] Authors: Priyanka Bonde ,R.R.Borase,J.G.Patil
[IJET-V1I6P8] Authors: Priyanka Bonde ,R.R.Borase,J.G.Patil[IJET-V1I6P8] Authors: Priyanka Bonde ,R.R.Borase,J.G.Patil
[IJET-V1I6P8] Authors: Priyanka Bonde ,R.R.Borase,J.G.Patil
 
Integrated Air Conditioning Unit for Automobiles
Integrated Air Conditioning Unit for AutomobilesIntegrated Air Conditioning Unit for Automobiles
Integrated Air Conditioning Unit for Automobiles
 
Performance Gain for Multiple Stage Centrifugal Compressor by usi.pdf
Performance Gain for Multiple Stage Centrifugal Compressor by usi.pdfPerformance Gain for Multiple Stage Centrifugal Compressor by usi.pdf
Performance Gain for Multiple Stage Centrifugal Compressor by usi.pdf
 
L356367
L356367L356367
L356367
 
L356367
L356367L356367
L356367
 
www.ijerd.com
www.ijerd.comwww.ijerd.com
www.ijerd.com
 
PERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANT
PERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANTPERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANT
PERFORMANCE EVALUATION AND OPTIMIZATION OF AIR PREHEATER IN THERMAL POWER PLANT
 
30120140507005
3012014050700530120140507005
30120140507005
 
30120140507005
3012014050700530120140507005
30120140507005
 
Development of vapour absorption refrigeration system in vehicles
Development of vapour absorption refrigeration system in vehiclesDevelopment of vapour absorption refrigeration system in vehicles
Development of vapour absorption refrigeration system in vehicles
 
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
 
78201906
7820190678201906
78201906
 
78201906
7820190678201906
78201906
 
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
 
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
 
GAS TURBINE POWER PLANTS INLET AIR COOLING
GAS TURBINE POWER PLANTS INLET AIR COOLINGGAS TURBINE POWER PLANTS INLET AIR COOLING
GAS TURBINE POWER PLANTS INLET AIR COOLING
 

Mais de Arun Prakash

Fusion 360 architecture
Fusion 360 architectureFusion 360 architecture
Fusion 360 architectureArun Prakash
 
Independent Autodesk Building Performance Analysis Certificate_arunprakash
Independent Autodesk Building Performance Analysis Certificate_arunprakashIndependent Autodesk Building Performance Analysis Certificate_arunprakash
Independent Autodesk Building Performance Analysis Certificate_arunprakashArun Prakash
 
An economical yet eco friendly way to provide shelter
An economical yet eco friendly way to provide shelterAn economical yet eco friendly way to provide shelter
An economical yet eco friendly way to provide shelterArun Prakash
 
HVAC for Beginners an Insight
HVAC for Beginners an InsightHVAC for Beginners an Insight
HVAC for Beginners an InsightArun Prakash
 

Mais de Arun Prakash (6)

Fusion 360 architecture
Fusion 360 architectureFusion 360 architecture
Fusion 360 architecture
 
Independent Autodesk Building Performance Analysis Certificate_arunprakash
Independent Autodesk Building Performance Analysis Certificate_arunprakashIndependent Autodesk Building Performance Analysis Certificate_arunprakash
Independent Autodesk Building Performance Analysis Certificate_arunprakash
 
dizinwrkx profile
dizinwrkx profiledizinwrkx profile
dizinwrkx profile
 
An economical yet eco friendly way to provide shelter
An economical yet eco friendly way to provide shelterAn economical yet eco friendly way to provide shelter
An economical yet eco friendly way to provide shelter
 
HVAC for Beginners an Insight
HVAC for Beginners an InsightHVAC for Beginners an Insight
HVAC for Beginners an Insight
 
Project Thesis
Project ThesisProject Thesis
Project Thesis
 

Último

MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLMONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLSeo
 
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxB.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxpriyanshujha201
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...anilsa9823
 
M.C Lodges -- Guest House in Jhang.
M.C Lodges --  Guest House in Jhang.M.C Lodges --  Guest House in Jhang.
M.C Lodges -- Guest House in Jhang.Aaiza Hassan
 
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfDr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfAdmir Softic
 
Call Girls in Gomti Nagar - 7388211116 - With room Service
Call Girls in Gomti Nagar - 7388211116  - With room ServiceCall Girls in Gomti Nagar - 7388211116  - With room Service
Call Girls in Gomti Nagar - 7388211116 - With room Servicediscovermytutordmt
 
Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Neil Kimberley
 
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Lviv Startup Club
 
Value Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsValue Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsP&CO
 
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...Aggregage
 
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756dollysharma2066
 
7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...Paul Menig
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangaloreamitlee9823
 
HONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsHONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsMichael W. Hawkins
 
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...amitlee9823
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756dollysharma2066
 
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...Any kyc Account
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear RegressionRavindra Nath Shukla
 

Último (20)

MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLMONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
 
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxB.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
 
M.C Lodges -- Guest House in Jhang.
M.C Lodges --  Guest House in Jhang.M.C Lodges --  Guest House in Jhang.
M.C Lodges -- Guest House in Jhang.
 
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfDr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
 
Call Girls in Gomti Nagar - 7388211116 - With room Service
Call Girls in Gomti Nagar - 7388211116  - With room ServiceCall Girls in Gomti Nagar - 7388211116  - With room Service
Call Girls in Gomti Nagar - 7388211116 - With room Service
 
Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023
 
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
VVVIP Call Girls In Greater Kailash ➡️ Delhi ➡️ 9999965857 🚀 No Advance 24HRS...
 
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
 
Value Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsValue Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and pains
 
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
 
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabiunwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
 
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
 
7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
 
HONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsHONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael Hawkins
 
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
KYC-Verified Accounts: Helping Companies Handle Challenging Regulatory Enviro...
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear Regression
 

Reducing ac power consumption by compressor downsizing on a sport

  • 1. Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Reducing AC Power Consumption By Compressor Downsizing on a Sports Utility Vehicle D. Srinivasan Tata Motors Ltd. Prasad Phadke Tata Motors Ltd. Follow this and additional works at: http://docs.lib.purdue.edu/iracc Srinivasan, D. and Phadke, Prasad, "Reducing AC Power Consumption By Compressor Downsizing on a Sports Utility Vehicle" (2006). International Refrigeration and Air Conditioning Conference. Paper 844. http://docs.lib.purdue.edu/iracc/844 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html
  • 2. R048, Page 1 REDUCING AC POWER CONSUMPTION BY COMPRESSOR DOWNSIZING ON A SPORTS UTILITY VEHICLE D Srinivasan*, Prasad Phadke Climate Control Group, Engineering Research Centre, TATA Motors Ltd. Pune – 411018, Maharashtra, India. Tel: +91-20-56133226, Fax: +91-20-56131960 *Corresponding author Email: d.srinivasan@tatamotors.com ABSTRACT Reducing AC power consumption in an automobile is one of the key challenges for climate control engineers. The AC compressor consumes power from the engine which directly affects fuel economy and vehicle drivability. The main objective of this study is to reduce front end auxiliary drive (FEAD) load on engine by compressor downsizing, without compromising on cooling performance of the AC system. The study has been carried out on a sports utility vehicle (SUV) which has twin evaporator AC system. The three compressors under study have been critically evaluated at three levels a) Component level b) System level and c) Vehicle level. The study has been conducted in two phases 1) downsizing from 170 cc/rev reciprocating piston compressor to 130 cc/rev compressor and 2) further downsizing from 130 cc/rev reciprocating piston compressor to 90 cc/rev rotary scroll compressor. The results of this study demonstrate that AC power consumption and refrigerant quantity are reduced by 25% and 5% respectively. Key words: Automobile climate control, front end auxiliary drive load, power consumption, compressor downsizing. 1. INTRODUCTION One of the primary functions of an automobile climate control system is to provide the desired cooling and stabilise cabin temperatures to comfortable levels in hot climatic conditions. With the increasing demand for more energy efficient systems and thermal comfort in automobiles, the automobile AC system needs to be optimized to deliver the required cooling performance with minimum AC power consumption. Proper selection and integration of AC compressor with other system aggregates results in improved energy efficiency of the system. Geon and Tae (2004) have mentioned about the importance of AC power consumption reduction in their study. Urchueguia et al. (2003) have carried out experiments with scroll and reciprocating compressors using R22 and propane as refrigerant, for a commercial type refrigeration unit of nominal capacity of about 20kW. Kapoor et al. (2004) have carried out experiments with reciprocating and scroll compressors on a small car automotive air conditioning system and found that 60 cc/rev scroll compressor delivers an equivalent cooling with 20% reduction in power consumption as compared to a 110 cc/rev reciprocating piston compressor. Perevozchikov and Pham (2004) have shown that variable speed scroll compressor gives superior performance over conventional compressors in terms of efficiency and reliability. The SUV considered for this study is originally equipped with 170 cc/rev reciprocating piston compressor. The study of various compressors shows that for the same application, a smaller capacity compressor can be used to reduce AC power consumption and still can maintain the same level of cooling by optimizing the AC system aggregates. In addition, by deploying scroll compressor technology, the compressor capacity can be further downsized, making the system even more energy efficient. In case of conventional reciprocating piston type swash plate compressors, frictional losses are high due to the reciprocating motion of pistons past the walls of the cylinders, resulting in lower efficiencies. In case of a scroll compressor, its typical internal construction and compression mechanism reduces the frictional losses and increases International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
  • 3. R048, Page 2 the efficiency. In a scroll compressor, there are two spiral-shaped scroll members, one stationary scroll and the other scroll orbiting relative to the stationary scroll. These two members fit together forming crescent shaped pockets. As the orbiting motion continues, refrigerant is drawn in from the outer ends and forced toward the center of the scroll form gradually increasing refrigerant pressure. The high pressure refrigerant is then discharged from the center port of the fixed scroll member. 2. METHODOLOGY The methodology adopted for this study is to experimentally evaluate the power consumption and cooling performance of the three AC compressors under study at three different levels a) component level calorimetric test b) system level bench test and c) vehicle level dynamometer test. This study has been carried out in two distinct phases. 2.1 Phase 1: In phase 1, 170 cc/rev reciprocating piston compressor is compared with 130 cc/rev reciprocating piston compressor. Both these compressors have similar technology and are similar in construction. For 130 cc/rev compressor, the AC system has been reconfigured with change in capacity of thermostatic expansion valve and refrigerant charge quantity as compared to the existing AC system. 2.2 Phase 2: In phase 2, 130 cc/rev reciprocating piston compressor is compared with 90 cc/rev rotary scroll compressor. These two compressors are different in both, technology and construction. There is no change in the system configuration and refrigerant charge quantity for these two compressors. 3. TEST CONDITIONS 3.1 Compressor Calorimetric Test All the three compressors under study are tested as stand alone on a compressor calorimeter, under identical test conditions (LP=1.76 bar, HP=16.4 bar, SH=10°C, SC=5°C). The set points represent the typical vehicle operating conditions. The compressor cooling capacity and power consumption are evaluated at four different engine speeds. 3.2 System level Bench Test The experimental set up consisted of original components from the R134a system of a typical twin evaporator AC system of SUV. The set up as shown in Figure 1 consists of three environmental chambers for the compressor, condenser and evaporator. The compressor drive motor is housed in a fourth chamber. Evaporator 2 (roof mount) Evaporator 1 (underdash) Condenser Compressor Motor Evaporator Room Condenser Room Compressor Room Figure 1: Schematic diagram for Bench test set up The compressor chamber holds the compressor at a desired temperature to simulate temperature conditions in the engine compartment of the car. The compressor is run by the electrical motor acted upon by frequency converter in order to cover the whole range of rotational speed in the actual vehicle. Condenser and evaporator chambers contain International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
  • 4. R048, Page 3 a wind tunnel with variable speed blower and temperature controller, enabling a wide range of air flow rates and temperatures for the condenser and evaporator chambers respectively. The evaporator chamber also has a steam supply and humidity controller to provide latent heat load. In addition the evaporators are kept in the original plastic casing to preserve the same air circuit and flow rate as in the actual vehicle. The test condition is designed to represent actual vehicle operating conditions. On the test bench, the compressor speeds for all three compressors were set corresponding to engine speed as on the vehicle. There are five engine speeds from 950 rpm to 4000 rpm simulating vehicle idling to high cruising speeds. The ambient air around the compressor is maintained at 100°C and the condenser at 45°C. Air flow rate across the condenser is related to vehicle speed. In stationary idling condition, the velocity is restricted to 1 m/s whereas at cruising speed of 80 kmph, the velocity is set to 4.5 m/s. The inlet air condition for the evaporator is 35°C / 60% RH. Air flow rate set over evaporator 1 is 400 m3/hr and over evaporator 2 is 180 m3/hr. These typically are the air flow rates at the maximum blower speed for a twin evaporator AC system of SUV. In the bench test, cooling capacity and power consumption of the AC compressor at the system level has been evaluated across engine speeds. 3.3 Vehicle level dynamometer Test The SUV is tested on a chassis dynamometer with the three compressors. The tests are conducted under identical test conditions to evaluate the AC power consumption. The tests are done at five vehicle speeds in 5th gear full throttle condition. To ensure that the AC system is fully loaded and the compressor works continuously during the test, the windows are kept open and the anti-icing device is bypassed. 4. EXPERIMENTAL RESULTS 4.1 Phase 1: 170 cc/rev compressor (reciprocating) vs. 130 cc/rev compressor (reciprocating) 4.1.1 Compressor Calorimetric Test: Figure 2 shows comparative performance of the two compressors in the compressor calorimeter. The power consumption of 130 cc/rev compressor is 5% to 18% lesser than 170 cc/rev compressor across engine speeds. The result also demonstrates that cooling capacity of 130 cc/rev compressor is lesser by 13% to 24% than 170 cc/rev compressor as stand alone component. 170 cc/rev (reciprocating) 130 cc/rev (reciprocating) Cooling capacity & Power consumption (kW) 10.0 9.0 Test conditions LP = 1.76 bar HP = 16.4 bar SH = 10°C SC = 5°C 8.0 7.0 Cooling capacity 6.0 5.0 4.0 Power consumption 3.0 2.0 1.0 0.0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Engine speed (rpm) Figure 2: Compressor calorimetric test – 170 cc/rev vs 130 cc/rev 4.1.2 System Bench test: Figure 3 shows the bench level performance of the two compressors. The result demonstrates that power consumption of 130 cc/rev compressor is lower by 1% to 9% below 2500 rpm and higher by 2% to 5% above 2500 rpm compared to 170 cc/rev compressor. The combined cooling capacity of the twin evaporator system with 130 cc/rev compressor is lower by 3% compared to 170cc/rev compressor below 1750 rpm and higher by 2% above 1750 rpm. International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
  • 5. R048, Page 4 170 cc/rev (reciprocating) 130 cc/rev (reciprocating) Cooling capacity & Power consumption (kW) 7.00 6.00 Cooling capacity 5.00 Power consumption 4.00 3.00 2.00 1.00 0.00 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Engine speed (rpm) Figure 3: Bench test – 170 cc/rev vs 130 cc/rev By optimising the capacity of thermostatic expansion valve and refrigerant charge quantity, the 130cc/rev compressor when coupled with other AC system aggregates delivers the same cooling performance as 170 cc/rev compressor with less power consumption. This demonstrates that 130 cc/rev compressor is better optimised with the other AC system aggregates. The refrigerant charge quantity for the twin evaporator system with 130 cc/rev compressor is reduced from existing 950 gms to 900 gms. The 170 cc/rev compressor, which delivers higher cooling capacity at component level (stand alone), delivers lower cooling performance when coupled with other AC system aggregates. This demonstrates that 170 cc/rev compressor is overcapacity for the existing AC system. 4.1.3 Vehicle level dynamometer test: Figure 4 shows the AC system power consumption across vehicles speeds with 170 cc/rev compressor and 130 cc/rev compressor. Test results demonstrate that 130 cc/rev compressor consumes 8% to 15% lesser power compared to 170 cc/rev compressor. This reduction in power consumption is achieved with the same level of cooling performance. 170 cc/rev compressor 130 cc/rev compressor 4 AC power consumption (kW) 3.5 3 2.5 2 1.5 1 0.5 0 30 40 45 55 75 Vehicle speed (Kmph) Figure 4: Chassis dynamometer test – 170 cc/rev vs 130 cc/rev International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
  • 6. R048, Page 5 At the end of phase 1, the test results demonstrate that at all three levels 130 cc/rev compressor consumes lesser power as compared to 170cc/rev compressor. The results also show that after optimising the AC system aggregates, 130 cc/rev compressor delivers same cooling performance as that of 170 cc/rev compressor. Based on these advantages, 170 cc/rev reciprocating compressor has been replaced by 130 cc/rev reciprocating compressor on the vehicle. 4.2 Phase 2: 130 cc/rev compressor (reciprocating) vs. 90 cc/rev compressor (scroll) 4.2.1 Compressor Calorimetric Test: Figure 5 shows comparative performance of the two compressors in the compressor calorimeter. The power consumption of 90 cc/rev scroll compressor is 2% to 13% lower than 130 cc/rev reciprocating compressor across engine speeds. The result also demonstrates that cooling performance of scroll compressor is 4% to 30% higher than reciprocating compressor as stand alone component. The performance curves for 170 cc/rev compressor are shown with dotted lines for reference. 170 cc/rev (reciprocating) 130 cc/rev (reciprocating) 90 cc/rev (scroll) 12.0 Cooling capacity & Power consumption (kW) 11.0 Test conditions LP = 1.76 bar HP = 16.4 bar SH = 10°C SC = 5°C 10.0 9.0 Cooling capacity 8.0 7.0 6.0 5.0 4.0 Power consumption 3.0 2.0 1.0 0.0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Engine speed (rpm) Figure 5: Compressor calorimetric test – 130 cc/rev vs 90 cc/rev 4.2.2 System Bench Test: Figure 6 shows the bench level performance of 130 cc/rev reciprocating and 90 cc/rev scroll compressor. The power consumption of scroll compressor is lower by 5% to 20% compared to reciprocating 170 cc/rev (reciprocating) 130 cc/rev (reciprocating) 90 cc/rev (scroll) Cooling capacity & Power consumption (kW) 8.00 7.00 Cooling capacity 6.00 5.00 Power consumption 4.00 3.00 2.00 1.00 0.00 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Engine speed (rpm) Figure 6: Bench test – 130 cc/rev vs 90 cc/rev International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
  • 7. R048, Page 6 compressor below 2400 engine rpm. The combined cooling performance of twin evaporator system with 90 cc/rev scroll compressor is higher by 4% to 12% compared to 130 cc/rev reciprocating compressor across engine speeds. Without making any modifications in the system and with same refrigerant charge quantity (900 gms) as that of reciprocating compressor, the scroll compressor delivers more cooling performance with less power consumption. The scroll compressor which delivers higher cooling performance at component level (stand alone), once again demonstrates higher cooling performance when coupled with other AC system aggregates at bench level. This shows that scroll compressor is well optimised with AC system aggregates. The performance curves for 170 cc/rev compressor are shown with dotted lines for reference. 4.2.3 Vehicle level dynamometer test: Figure 7 shows the AC system power consumption across vehicles speeds with 130 cc/rev reciprocating compressor and 90 cc/rev scroll compressor. Test results demonstrate that scroll compressor consumes 16% to 25% lesser power compared to reciprocating compressor. This reduction in power consumption is achieved with the same level of cooling performance. The values for 170 cc/rev reciprocating compressor are also captured for reference. 170 cc/rev (reciprocating) 130 cc/rev compressor (reciprocating) 90 cc/rev (scroll) 4 AC power consumption (kW) 3.5 3 2.5 2 1.5 1 0.5 0 30 40 45 55 75 Vehicle speed (Kmph) Figure 7: Chassis dynamometer test – 130 cc/rev vs 90 cc/rev At the end of phase 2, the test results demonstrate that at all three levels 90 cc/rev scroll compressor consumes lesser power compared to 130 cc/rev reciprocating compressor. It also shows that 90 cc/rev scroll compressor delivers higher cooling performance than that of 130 cc/rev reciprocating compressor with no change in the AC system aggregates. Based on these advantages, 90 cc/rev scroll compressor has been recommended to replace 130 cc/rev reciprocating compressor. 5. CONCLUSIONS The main focus of the present study is reduction in the AC power consumption by compressor downsizing. A methodical approach of three way experimental evaluation in two phases has been followed to realize the objective. • In phase 1, by downsizing the AC compressor from 170 cc/rev to 130 cc/rev capacity, 8% to 15% reduction in power consumption is achieved. • In phase 2, by downsizing the AC compressor from 130 cc/rev to 90 cc/rev capacity, 16% to 25% reduction in power consumption is achieved. • Overall, there is 24% to 30% reduction in AC power consumption by replacing 170 cc/rev reciprocating compressor with 90 cc/rev scroll compressor. The lower power consumption of scroll compressor can be attributed solely to its internal construction, compression mechanism, and lower frictional losses. • Furthermore, there is 5% reduction in refrigerant charge quantity because of compressor downsizing. All these benefits are achieved without any deterioration in the AC cooling performance. The scroll compressor offers the added benefits of low noise, higher continuous speeds and improved drivability. Advancements in International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006
  • 8. R048, Page 7 compressor technology offer opportunities to further reduce the AC power consumption and refrigerant charge quantity. ABBREVIATIONS HP LP RH SC SH AC High pressure Low pressure Relative Humidity Sub cooling Superheating Air conditioning REFERENCES Geon Lee, Tae Lee, 2004, A study on the variable displacement mechanism of swash plate type compressor for automotive air conditioning system, Int. Compressor Engineering Conference at Purdue: C079 Urchueguia Javier F., Jose Miguel Corberan, Jose Gonzalvez, Jose Miguel Diaz, 2003, Experimental characterization of a commercial size scroll and reciprocating compressor working with R22 and propane (R290) as refrigerant. Int. Congress of Refrig., Washington DC, Session B2–1, p. 1–8 Kapoor S.H., Paramane S., Dr Arora G., 2004, Application of energy efficient scroll compressor for small cars, Int. Refrigeration and Air conditioning Conference at Purdue: R060 Perevozchikov M.M., Pham H.M., 2004, Scroll compressor for mobile HVAC/R application, Int. Compressor Engineering Conference at Purdue: C095 ACKNOWLEDGEMENT The authors gratefully acknowledge the support provided to this work by Tata Motors Ltd, Pune, India. The authors also acknowledge the guidance and support given by Mr. Hirak Mukherjee from MHI, India. International Refrigeration and Air Conditioning Conference at Purdue, July 17 – 20, 2006