SlideShare uma empresa Scribd logo
1 de 31
Baixar para ler offline
SMP14
    Racking your Power System Hardware …
    Without Aspirin

                  Mark Olson
                  IBM WW Power Systems Product Manager




      STG Technical Conferences 2009                                                    © 2009 IBM Corporation




           STG Technical Conferences 2009

Current Hardware Can Be Racked

    19-inch System Units                                 19-inch I/O Drawers

    Power 520                                     #5802   (12X DDR I/O)
    Power 550                                     #5796, 5714-G30       (12X I/O)
    Power 560                                     #5790, 5711-D11       (HSL/RIO I/O)

    Power 570                                     #0595, 5711-D20       (HSL/RIO I/O)

    POWER5 520/515/525                            #5294/5296 (HSL/RIO I/O)
    POWER5 550                                    #5094/5096 (HSL/RIO I/O)              RPQ

    POWER5 570                                    #0588 (HSL/RIO I/O)

                                                  #5786, (SCSI Disk drawer)
                                                  #5886 (SAS Disk drawer)

                                                  7212/7214    (tape/DVD drawer)


2          Racking Your Power System … Without Aspirin                                    © 2009 IBM Corporation




                                                                                                                   1
STG Technical Conferences 2009

Three 19-inch Rack Sizes (Power Systems)
                             “Standard” 19-inch racks




                      2m                            1.8m                         1.3m
                      42U                           36U                          25U
    Note the term “standard” can be wildly misleading when looking across vendors. Though the width of 19”
    between holes in the vertical support posts is standard, many other aspects follow guidelines/standards which
    are open to considerable differences in interpretation.

3               Racking Your Power System … Without Aspirin                                              © 2009 IBM Corporation




                STG Technical Conferences 2009

Agenda


         • Racking 19-inch IBM System Units: 520, 550, 560, 570
         • Racking 19-inch IBM I/O Drawers :
            – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
              #5094/96
            – Disk only drawer: #5786, #5886
         • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
         •   IBM Rack Options
         •   IBM Power Distribution Units (PDU)                              #7188, #7109
         •   IBM Rack UPS
         •   IBM Tape and racks
         •   Nuts & bolts
         •   Using different IBM or OEM Racks



4               Racking Your Power System … Without Aspirin                                              © 2009 IBM Corporation




                                                                                                                                  2
STG Technical Conferences 2009

Power 520 Tower & Rack-mount
    8203-E4A
                                                                                                             4U


                                                               Conversions
                                                               announced
                                                               Feb 2009

      Order tower using                                                           Order rackmount using
       – #7112 Covers & door (lockable)                                             – #7200 rack-mount specify
                                                                                    – #7114 bezel, adjust depth rails,


                       #7112                 #7200 conversion ships hardware, BUT
        Must also order for rackmount:                                                Must also order for tower:
         • Ops panel cable #1877                                                       • Ops panel cable #1843
         • #7114 rail kit                                                              • Non-PDU power cords
         • Probably PDU power cords
         • Rack/PDU if needed



5                  Racking Your Power System … Without Aspirin                                                            © 2009 IBM Corporation




                   STG Technical Conferences 2009

Power 550 Rack-mount & Tower
    8204-E8A
                                    4U



                                                                   No field conversions




      Order rackmount using                                                   Order tower using
       – #7360 rack-mount specify                                               – #7292 Covers & door (lockable)
       – #7146 bezel, adjust depth rails,




      FYI - The vast majority of Power 550 shipped from IBM are rackmount. Almost zero requests for footprint conversions have been
      received for either POWER5 550 or POWER6 550. Therefore IBM has not created the ordering/shipping/billing structure to do such
      a conversion and has no plans at this time to create this structure.




6                  Racking Your Power System … Without Aspirin                                                            © 2009 IBM Corporation




                                                                                                                                                   3
STG Technical Conferences 2009

Model 560/570 - Racking Insights
    8234-EMA, 9117-MMA




                               4U (4 EIA)
                            Processor drawer

      • All 560/570 are 19” rackmount only.
        Adjustable depth rails are included
                                                                       If creating 2-drawer, 3-
      • 560/570 bigger than 1 drawer has rack                          drawer or 4-drawer
                                                                       configuration, processor
        implications, both for IBM and OEM                             drawers must be
                                                                       installed adjacent to one
        racks.                                                         another.



7             Racking Your Power System … Without Aspirin                      © 2009 IBM Corporation




              STG Technical Conferences 2009

Agenda


        • Racking 19-inch IBM System Units: 520, 550, 560, 570
        • Racking 19-inch IBM I/O Drawers :
           – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
             #5094/96
           – Disk only drawer: #5786, #5886
        • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
        •   IBM Rack Options
        •   IBM Power Distribution Units (PDU)              #7188, #7109
        •   IBM Rack UPS
        •   IBM Tape and racks
        •   Nuts & bolts
        •   Using different IBM or OEM Racks



8             Racking Your Power System … Without Aspirin                      © 2009 IBM Corporation




                                                                                                        4
STG Technical Conferences 2009

#5802/5877 12X I/O Drawer                              (for POWER6 servers)




      5802 with disk bays                                  5877 no disk bays


              #5802/5877 12X I/O Drawer
              • 4U or 4 EIA
              • Adjustable depth rails
              • 10 PCIe slots, 18 or 0 SFF disk bays
              • 12X attach
              • PDU optional


     No #5802-equivalent deskside packaging option available
9        Racking Your Power System … Without Aspirin                               © 2009 IBM Corporation




         STG Technical Conferences 2009

#5796 12X I/O Drawer                          (for POWER6 servers)




                                                             #7314 Enclosure
                                                             • 4U or 4 EIA
                                                             • 1 or 2 5796 per #7314
                 #5796                             #5796       – adjustable depth rails


            #5796 12X I/O Drawer
            • Fits in ½ of 4U enclosure
            • 6 PCI-X DDR slots per 5796
                                                                     #5796 is System i heritage, but
            • 12X attach                                             7314-G30 drawer is essentially
                                                                     equivalent.
            • PDU optional

     No #5796-equivalent deskside packaging option available
10       Racking Your Power System … Without Aspirin                               © 2009 IBM Corporation




                                                                                                            5
STG Technical Conferences 2009

#5790 I/O Drawer



                                                            #7307 Enclosure
                                                            • 4U or 4 EIA
             #5790                  #5790
                                                            • 1 or 2 5790 per #7311/7307
                                                              – adjustable depth rails
                                                              – Earlier #7311 enclosure has
                                                                fixed depth rails
                #5790 I/O Drawer
                • Fits in ½ of 4U enclosure
                • 6 PCI-X slots per 5790
                                                                        #5790 is System i heritage, but
                • HSL/RIO attach                                        7311-D11 drawer is nearly
                • PDU optional                                          equivalent



       No #5790-equivalent deskside packaging option
11           Racking Your Power System … Without Aspirin                              © 2009 IBM Corporation




             STG Technical Conferences 2009

#0595 I/O Drawer
             withdrawn from marketing Aug 2009
                                                                          #0595 is System i heritage, but
                                                                          7311-D20 drawer is nearly
                                                                          equivalent, but only 4U

                                                    #0595
                                                    • 5U or 5 EIA
                                                    • 7 PCI-X slots and 12 disk bays
                                                    • HSL/RIO attach
                                                    • PDU optional
                                                    • Adjustable depth rails included




     #0595                                                                #5095


       Rackmount to deskside (or vice versa) conversions not available
12           Racking Your Power System … Without Aspirin                              © 2009 IBM Corporation




                                                                                                               6
STG Technical Conferences 2009

#0588 I/O Drawer
         Withdrawn from marketing mid 2006


                                             #0588
                                             • 8U or 8 EIA
                                             • 14 PCI-X slots and 0 disk bays
                                             • HSL/RIO attach
                                             • PDU required
                                             • Fixed depth rails included
                                                   – Adjustable rails not available
                                             • Previous generation = #0578


                                                                                  #5088
                     #0588                                                        #5094


     Rackmount to deskside (or vice versa) conversions not available
13       Racking Your Power System … Without Aspirin                                 © 2009 IBM Corporation




         STG Technical Conferences 2009

Racked I/O Tower
         Withdrawn from marketing May 2009



                            #5294/5296
                            • 36U 1.8m rack
                            • Total 28 PCI-X slots
                            • Total 90 (#5294) or 0 (#5296) disk bays
                            • HSL/RIO attach
                            • PDU not used
                            • Really two #5094/5096s installed inside a
                              1.8m rack and ordered as just #5294/5296




                                                  #8294 Same thing as 5294, but for 595
                                                  #5079 Same thing, but older generation #5074

14       Racking Your Power System … Without Aspirin                                 © 2009 IBM Corporation




                                                                                                              7
STG Technical Conferences 2009

Single #5094/5096 I/O Tower in a Rack
           Withdrawn from marketing May 2009



     • Chargeable RPQ 847215
                                                                                       Can put
     • IBM Manufacturing Plant only.                                                   520/525,
       Not installable at customer site.                                               550, 570,
                                                                                       I/O, etc
      – Weight of #5094/5096 prohibits                                                 here
        this being done at customer site
     • For model 520/525/550/570/595
       & 800/810/825/870/890
                                                                Rack
     • Once done, no IBM structure in                            36U #0551
                                                                 42U #0553
       place to remove #5094 from rack

                                                                #5094
                                                                  14 PCI-X slots and 15 + opt 30 disk slots
                                                                  #5094 uses 18U of rack space


15          Racking Your Power System … Without Aspirin                                         © 2009 IBM Corporation




            STG Technical Conferences 2009

#5786 EXP24 SCSI Disk Drawer
           SCSI disk withdrawn from marketing Aug 2009
                                                                                    #5786 is System i heritage, but
                                                                                    7031-D24 drawer is equivalent


                                                     #5786
                                                     • 4U or 4 EIA
                                                     • 24 3.5” disk bays and 0 PCI-X slots
                                                          – 12 slots in front, 12 slots in back
                                                          – 4 disk slot enablers in back
                                                     • PDU optional
                                                     • Adjustable depth rails included
                                                                            #5787




                                                                                      Tower withdrawn
             #5786                                                                    from marketing in
                                                                                      2008



       Rackmount to tower (or vice versa) conversions not available
16          Racking Your Power System … Without Aspirin                                         © 2009 IBM Corporation




                                                                                                                         8
STG Technical Conferences 2009

EXP 12S SAS Disk Drawer #5886




         • 2U or 2EIA disk drawer
         • 12 SAS 3.5” disk bays and 0 PCI slots per drawer
         • Adjustable depth rails included
         • Dual power supplies (two power cords)
         • Rack only …. No tower option


17         Racking Your Power System … Without Aspirin                  © 2009 IBM Corporation




           STG Technical Conferences 2009

Agenda


     • Racking 19-inch IBM System Units: 520, 550, 560, 570
     • Racking 19-inch IBM I/O Drawers :
        – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
          #5094/96
        – Disk only drawer: #5786, #5886
     • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
     •   IBM Rack Options
     •   IBM Power Distribution Units (PDU)              #7188, #7109
     •   IBM Rack UPS
     •   IBM Tape and racks
     •   Nuts & bolts
     •   Using different IBM or OEM Racks



18         Racking Your Power System … Without Aspirin                  © 2009 IBM Corporation




                                                                                                 9
STG Technical Conferences 2009

Power Systems Racking
     System i
     Feature coded racks
                                                                   Power Systems
     (#055x)
                                                                   Feature coded &
                                                                   machine type/model
                                                                   (#055x & 7014-xxx)

                                                            • Use 7014-xxx if ordering a new
                                                              server. Can order along with server
                                                              MES order if don’t need integrated at
                                                              IBM plant with MES.
                                                            • Use #055x if ordering as MES. IBM
     System p                                                 plan can integrate with other I/O
     Machine type/model                                       drawer or system upgrade MES on
                                                              the same order.
     (7014-xxx)

                                                        Note: in 2009 maintenance pricing for #0551/0553/0554/0555 on
                                                        POWER6 8203/8204/8234/9117/91119 was added to make it
                                                        consistent with maintenance pricing on 7014 racks.
19        Racking Your Power System … Without Aspirin                                                     © 2009 IBM Corporation




          STG Technical Conferences 2009

Four/Three Power Systems Racks
      7014-T42
      #0553                       7014-T00
      7014-B42                    #0551
                                                                  7014-S25                              7014-S11
                                                                  #0555*                                #0554
                                                                                                          Withdrawn
                                                                                                          From
                                                                                                          marketing




           2m                            1.8m                          1.3m                              0.6m
          (79”)                          (71”)                         (49”)                              (24”)
          42U                            36U                           25U                                11U
         #0553                          #0551                         #0555                              #0554

20        Racking Your Power System … Without Aspirin       * not orderable as #0555 for most servers     © 2009 IBM Corporation




                                                                                                                                   10
STG Technical Conferences 2009

2 Meter Rack (42U)

                                                           •   42 EIA or 42U
                                                           •   28-inch depth between vertical supports
                                                           •   EIA 310-D mounting hole pattern
                                                           •   Frame is 36U rack with 6U extension

                                                           • Same basic rack (i, p, TS), ordered differently
                                                                •   #0553 Power Systems MES & System i
                                                                •   7014-T42 Power Systems & System p
                                                                •   7014-B42 for BladeCenter
                                                                •   9308-42S/4P_       System x
                                                                •   2101-N42 TotalStorage
WIDTH - exterior                                                •   Different rack accessories offered between #055x, 7104,
     With side panels                  644 mm (25.4 in)
                                                                    9308
     Without side panels               623 mm (24.5 in)
DEPTH – interior (rail to rail) 28 in
DEPTH - exterior                                           • 19-inch, industry standard rack. BUT other
     Rear door only (front trim kit)   1042 mm (41.0 in)     vendors’ depth and hole patterns can vary
     Regular front & rear doors        1098 mm (43.3 in)

HEIGHT                                 2015 mm (79.3 in)
WEIGHT empty                           261 kg (575 lb)



21                      Racking Your Power System … Without Aspirin                                           © 2009 IBM Corporation




                        STG Technical Conferences 2009

1.8 Meter Rack (36U)

                                                           • 36 EIA or 36U
                                                           • 28-inch depth between vertical supports
                                                           • EIA 310-D mounting hole pattern


                                                           • Same basic rack (i, p, TS), ordered differently
                                                                •   #0551 Power Systems MES & System i
                                                                •   7014-T00 Power Systems & System p
                                                                •   2101-200, -N00 TotalStorage
                                                                •   n/a      System x
                                                                •   Different rack accessories offered between #055x, 7104,
WIDTH - exterior                                                    & 2101
     With side panels                  644 mm (25.4 in)
     Without side panels               623 mm (24.5 in)
                                                           • 19-inch, industry standard rack. BUT other
DEPTH – interior (rail to rail) 28 in
DEPTH - exterior
                                                             vendors’ depth and hole patterns can vary
     Rear door only (front trim kit) 1042 mm (41.0 in)
     Regular front & rear doors        1098 mm (43.3 in)
HEIGHT                                 1804 mm (71.0 in)
WEIGHT empty                           244 kg (535 lb)


22                      Racking Your Power System … Without Aspirin                                           © 2009 IBM Corporation




                                                                                                                                       11
STG Technical Conferences 2009

1.3 Meter Rack (25U)

                                                      • 25 EIA or 25U
                                                      • 28-inch depth between vertical supports
                                                      • EIA 310-D mounting hole pattern
                                                         • But square holes, unlike 1.8m or 2m rack

                                                      • Same basic rack (i, p, x), ordered differently
                                                         • #0555 System i, feature code
                                                         • 7014-S25 System p
                                                         • 9308-2SX System x
                                                      • No accessories - base includes:
                                                         • Front & rear lockable doors
 WIDTH - exterior
                                                         • Front filler panels if empty from plant
     With side panels            610 mm (24.0 in)
     Without side panels         590 mm (23.2 in)     • Narrower than 1.8 or 2 meter rack
 DEPTH – interior (rail to rail) 28 in
                                                         • PDU placement impacted
 DEPTH - exterior
                                                         • Model 570 processor drawer restriction
     Regular front & rear doors   1000 mm (39.4 in)
 HEIGHT                           1240 mm (49 in)
 WEIGHT empty                     102 kg (221 lb)




23                  Racking Your Power System … Without Aspirin                                      © 2009 IBM Corporation




                    STG Technical Conferences 2009

Agenda


            • Racking 19-inch IBM System Units: 520, 550, 560, 570
            • Racking 19-inch IBM I/O Drawers :
               – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
                 #5094/96
               – Disk only drawer: #5786, #5886
            • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
            •   IBM Rack Options
            •   IBM Power Distribution Units (PDU)                              #7188, #7109
            •   IBM Rack UPS
            •   IBM Tape and racks
            •   Nuts & bolts
            •   Using different IBM or OEM Racks



24                  Racking Your Power System … Without Aspirin                                      © 2009 IBM Corporation




                                                                                                                              12
STG Technical Conferences 2009

42U/36U Rack Options (2m/1.8m)
Base Definition Includes


      7014-T42/T00                                                                                        #0553/0551

      Perforated rear door*                                                                               Perforated rear door*

      No side panels (optional)                                                                           Side panels
      Front filler panes (if                                                                              Front filler panes (if
      space empty when shipped)                                                                           space empty when shipped)

      One PDU (rest optional)                                                                             No PDU             (all optional)
          Choose #9188 or #5889

      Anti-tip plate                                                                                      Anti-tip plate




     7014-B42 basically the same as
     7014-T42 but all PDU optional
                                                                    * regular rear door not shipped if acoustic doors option ordered

25                    Racking Your Power System … Without Aspirin                                                                  © 2009 IBM Corporation




                      STG Technical Conferences 2009

42U/36U Rack Options
Must Choose: Trim Kit or Front Door
                                                     Regular                                                  Acoustic
        Trim kit                                     Front door                                               Front door*
        #6246/6247                                   #6068/6069                                               #6248/6249


                                                                                                                                        * Acoustic
                                                                                                                                        doors feature
                                                                                                                                        ships both
                                                                                                                                        front & back
                                                                                                                                        door




       Easy access                                 Perforated steel                                      ~6 dB(A) quieter
       Good visibility                             Security option: door                                 Security option: door
                                                   lock & side panel                                     lock & side panel
                                                   lock #6580                                            lock #6580

26                    Racking Your Power System … Without Aspirin                                                                  © 2009 IBM Corporation




                                                                                                                                                            13
STG Technical Conferences 2009

42U/36U Racks
Other Options
     • Side Panel #6098 for 7014
     • Suite Attach #7780/7840 for server (existing), #6104/6086 for 7014 (new or existing)
        • Attaches multiple racks of same size, side-to-side
        • Remove side panels – connect rack frames
        • Additional stability
     • Ruggedized Rack               #7841 for server     (existing),   #6080 for 7014 (new or existing)
        • Allows bolting rack to floor and additional rack strengthening
        • Usually considered for earthquake zones
     • Spare front filler panels                #0599 server feat code
        • Helps maintain proper airflow (and looks better)
        • Package of (3) 1U and (1) 3U snap-on/off black filler panels
     • Rack extender            #6257 42U 7014
        • Adds 20” depth for cable management of InfiniBand switches
     • Shelf
        • Not ordered as a feature of 7014 or of server
        • Ordered as feature of the I/O unit which will sit on the shelf, example:
          some tape drives

27          Racking Your Power System … Without Aspirin                                          © 2009 IBM Corporation




            STG Technical Conferences 2009

42U/36U/25U Rack Option
Rack Modem Tray #6586

      • 1U tray for 19” rack
      • Holds up to two external modems …. This is NOT a shelf
      • Convenient for external modems of
         – rackmount HMC
         – system
      • Also supported in 25U and 11U racks




                                                                 Tray with modem installed


28          Racking Your Power System … Without Aspirin                                          © 2009 IBM Corporation




                                                                                                                          14
STG Technical Conferences 2009

“Cool Blue” Rear Door Option #6858
Rear Door Heat Exchanger (RDX)

     • Option for the 7014-T42 2m rack
       – Not an orderable feature for #0553 – though
         would physically work


     • Water cooled rear door removes heat
       from exhaust air flow.
     • Can help eliminate hot spots from
       computer room.
     • Can help avoid adding more air
       conditioning.



29             Racking Your Power System … Without Aspirin                  © 2009 IBM Corporation




               STG Technical Conferences 2009

Agenda


         • Racking 19-inch IBM System Units: 520, 550, 560, 570
         • Racking 19-inch IBM I/O Drawers :
            – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
              #5094/96
            – Disk only drawer: #5786, #5886
         • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
         •   IBM Rack Options
         •   IBM Power Distribution Units (PDU)              #7188, #7109
         •   IBM Rack UPS
         •   IBM Tape and racks
         •   Nuts & bolts
         •   Using different IBM or OEM Racks



30             Racking Your Power System … Without Aspirin                  © 2009 IBM Corporation




                                                                                                     15
STG Technical Conferences 2009

#7188 Power Distribution Unit (PDU)

                                        • #7188 PDU
                                           • Like a power strip on massive steroids
                                           • 12 outlets per PDU (six circuit breakers – 2
                                           outlets per breaker)
                                           • Up to 48 amps per PDU (depends on power cord
                                           from PDU to wall), up to 15 amps per breaker & 10
                                           amps per outlet




                                        • PDU power cords (equipment to PDU)



                                                    #1422 or #6458 IEC 320 C13/C14 PDU Cord connects PDU to
                                                    many racked devices.
                                                    # 6459 or #6664 right angle PDU cord used for #5790
 In 7014-T00 or T42 rack, first
                                                    Other power cords connect the PDU to the “wall/UPS” power.
 PDU can be no charge #9188

31                 Racking Your Power System … Without Aspirin                                           © 2009 IBM Corporation




                   STG Technical Conferences 2009

#7188 Power Distribution Unit (PDU)


                                           • Placed horizontally, require 1U space

                                           • Up to four #7188 can be placed vertically in
                                             “side pockets” of 1.8 or 2m rack and use
                                             zero U space. (note eConfig doesn’t track the horizontal PDUs)


               Drawer                      • For power redundancy, recommend
                                              • Two PDU per rack for equipment with dual power
                                              cords
                                              • Plug the equipment with dual power cords into
                                              different PDUs
                                              • Plug the PDUs into different power sources

                                                                       See planning web site for details
                                                                       http://publib.boulder.ibm.com/infocenter/eserver/v1r2s/e
                                                                       n_US/index.htm?info/iphad/f0551_pdu.htm

32                 Racking Your Power System … Without Aspirin                                           © 2009 IBM Corporation




                                                                                                                                  16
STG Technical Conferences 2009

#7109 Intelligent PDU+

                                                               • Physically/electrically very much
                                                                 like #7188 PDU

                                                               • #7109 provides continuous power
                                                                 usage data. Data sent to PC
                                                                 attached via Ethernet connection




        • PC running Active Energy
          Manager can monitor /
          display information.

 In 7014-T00 or T42 rack, first
 PDU can be partial charge #5889

33               Racking Your Power System … Without Aspirin                                 © 2009 IBM Corporation




                 STG Technical Conferences 2009

#7188 vs #7109 PDU Comparison
                                                                                         Newer

                                                                      #7188 PDU         #7109 PDU+
     12 client usable IEC 320-C13 outlets                                   Yes              Yes
     200-240 Volts AC, 1-phase                                              Yes              Yes
     10 Amps per outlet, 16 Amps per pair of outlets                        Yes              Yes
     Side pocket mount #0551, #0553 racks                                   Yes              Yes
     Horizontal mount taking 1U                                             Yes              Yes
     Height/Width: 43.9mm(1.73 in) / 447mm(17.6 in)                         Yes              Yes
     Supported on model 5xx & 8xx systems                                   Yes              Yes
     i5/OS release independent                                              Yes              Yes

     Depth                                                             232mm (9.13in)   350mm (13.8in)
     Continuously monitors power usage by outlet                            No               Yes
     Ethernet connection for sending usage data                             No               Yes



                            Other PDUs can be ordered from IBM, but not as part of feature code racks

34               Racking Your Power System … Without Aspirin                                 © 2009 IBM Corporation




                                                                                                                      17
STG Technical Conferences 2009

Additional PDU Points

     • 7014-B42 has a couple additional PDU options designed to support
       BladeCenter options

     • System x also has additional PDU offerings.


     • Temperature/Humidity probe is supported on System x equivalent of
       #7109 PDU. Being considered for 7014 racks. Demand TBD. Thus
       future support TBD.




35               Racking Your Power System … Without Aspirin                                      © 2009 IBM Corporation




                 STG Technical Conferences 2009

Uninterruptible Power Supply (UPS)
                     9910 UPS rack solutions offered through IBM
                      Model               U (EIA)                  U (EIA) extra battery
                                           UPS                          modules
                    9910-E33                   2U                    2U each (max qty 4)

                    9910-E50                   3U                    3U each (max qty 4)

                    9910-E65                   3U                    3U each (max qty 2)

                    9910-E82                   6U                    3U each (max qty 4)
                    9910-E83                   6U                    3U each (max qty 4)

                        For details see: http://www.powerware.com/ibm

      Details you’ll want to review on Powerware site include Watts available, number of power
      receptacles provided on UPS, PDU needed or not, etc




                                              Until January 2008, used “Pxx” models. Pxx and Exx models have
                                              same specifications (wattage, EIA, extra battery)
36               Racking Your Power System … Without Aspirin                                      © 2009 IBM Corporation




                                                                                                                           18
STG Technical Conferences 2009

Agenda


       • Racking 19-inch IBM System Units: 520, 550, 560, 570
       • Racking 19-inch IBM I/O Drawers :
          – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
            #5094/96
          – Disk only drawer: #5786, #5886
       • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
       •   IBM Rack Options
       •   IBM Power Distribution Units (PDU)                     #7188, #7109
       •   IBM Rack UPS
       •   IBM Tape and racks
       •   Nuts & bolts
       •   Using different IBM or OEM Racks



37           Racking Your Power System … Without Aspirin                         © 2009 IBM Corporation




             STG Technical Conferences 2009

Tape/Optical Rack Enclosure



                                             Picture is of 7212




     Functionally equivalent to tape/optical drives sitting on rack shelf
     (see next slide) … but rack optimized (space, power, cooling)

     • For SCSI:    7212 – 103 (newer) or 7212 – 102 (earlier)
     • 1 U rack enclosure which holds up to 2 drives in 19-inch rack
        – QIC 30GB or 50GB,               VXA- 2 or 320, 4mm,     DVD,   LTO-2
     • Adjustable depth rails -- 27 to 30.5 inch

     • For SAS:    7214 – 1U2
     • 1 U rack enclosure which holds up to 2 drives in 19-inch rack
        – DAT72, DAT160,LTO-4, DVD
     • Adjustable depth rails

38           Racking Your Power System … Without Aspirin                         © 2009 IBM Corporation




                                                                                                          19
STG Technical Conferences 2009

Tape/Optical Rack Kit (Shelf)


 The following drives can sit on a 19” rack shelf which is ordered as feature code
 #8723 of the drive (device not the system).

         7207-122 4GB QIC tape drive
         7207-330 30GB QIC tape drive
         7208-345 60GB 8mm tape drive
         7206-336 36GB 4mm tape drive
         7210-025 & -030 DVD-RAM drive
         358x LTO tape not listed here

     All of the above drives have:
              Width        250mm / 9.8in
              Height 55mm / 2.2in




39                Racking Your Power System … Without Aspirin                                     © 2009 IBM Corporation




                  STG Technical Conferences 2009
LTO and Enterprise Tape Library Rack Mounting Options

     LTO Tape Libraries – all are full rack width
         TS3100 3573 L2U (also HVEC models) Library with single drive and 24 cartridge slots, 2 EIA
              Rack mount kit is 3573 feat code #7002, rack power cord is 3573 feat code #9848
         TS3200 3573 L4U (also HVEC models) Library with 1 or 2 drives and 48 cartridge slots, 4 EIA
              Rack mount kit is 3573 feat code #7002, rack power cord is 3573 feat code #9848
              Specify Qty:2 of feat code #9848 if select optional additional power supply
         TS3310 3576 L5B Library base unit with 1 or 2 drives and 36 cartridge slots, 5 EIA
         3576 L5B + (1) E9U Library base and one expansion, up to 6 drives, 128 cartridge slots, 14 EIA
         3576 L5B + (2) E9U Library base and two expansions, up to 10 drives, 218 cartridge slots, 23 EIA
         3576 L5B + (3) E9U Library base and three expansions, up to 14 drives, 310 cartridge slots, 32 EIA
         3576 L5B + (4) E9U Library base and four expansions, up to 18 drives, 402 cartridge slots, 41 EIA
              A single rack mount kit 3576 feat code #7003 supports the L5B and all attached E9U’s.
              Specify one rack power cord 3576 feat code #9848 in each unit (base and expansions).

          3582 L23     Library with 1 or 2 drives and 24 cartridge slots, 4 EIA
              Rack mount kit is 3582 feat code #7003

          3583 L18, L36, L72 Library with up to 6 drives and 72 cartridge slots, 14 EIA
              Rack mount kit is 3583 feat code #8006

     Enterprise Tape Library – full rack width
         TS3400 3577 L5U Library with 1 or 2 TS1120 (3592 E05) drives and 18 cartridge slots, 5 EIA
               Rack mount kit is 3577 feat code #7004

                                                                      Author thanks Brannen Proctor for this foil.
40                Racking Your Power System … Without Aspirin                                     © 2009 IBM Corporation




                                                                                                                           20
STG Technical Conferences 2009

LTO and Enterprise Tape Drive Rack Mounting Options

     LTO Tape Drives and Autoloaders
     (external attachment – not the LTO-2 drive which goes inside the 520/550 CEC)
          3580 H11,H13,H23,L11,L13,L23            two units can sit side-by-side on same shelf
                4 EIA = unit (14.6 cm (5.75 in)) + shelf (.7 in)
                Rack shelf is 3580 feat code #8723
          3580 L33, L3H, H3L, H3S, L43, S43, H4S             only one unit per shelf (width = 25 cm (9.85 in))
                4 EIA = unit (12 cm (4.75 in)) + shelf (.7 in)
                Rack shelf is 3580 feat code #7003
          3581 F28,L38, F38,L38, F3H, L3H
                2 EIA = unit (8.9 cm (3.5 in))   shelf not required one unit per 2U
                Rack mount kit is 3581 feat code #7003
          3581 H17, L17, H13, L13, H23, L23 two units can sit side-by-side on same shelf
                5 EIA = unit (19 cm (7.48 in)) + shelf (.7 in)
                Rack shelf is 3581 feat code #7003

     Enterprise Tape Drives and Autoloaders
         3590 B11, E11, H11 (rack mount autoloader)
              12 EIA for the shelf/cabinet(s) to hold 1 or 2 drives
         3592 J1A, E05 TS1120 (rack mount drive only, no autoloader)
              10 EIA    for the shelf/cabinet(s) to hold 1 to 4 drives




41               Racking Your Power System … Without Aspirin                                      © 2009 IBM Corporation




                 STG Technical Conferences 2009

“Nuts & Bolts”


                                         “Cage nut” or “nut
                                         box” or “grommet”




                                           6 mm bolt
         5 mm bolt
                                                                            Cable hooks



                                                                  Handy things to have when installing
                                                                  • ratchet
                                                                  • power screw driver/drill
                                                                  • flash light – head lamp best
                                                                  • screw drivers
                                                                  • spare nuts/bolts cable ties
                                                                  • knife, tie cutters
42               Racking Your Power System … Without Aspirin                                      © 2009 IBM Corporation




                                                                                                                           21
STG Technical Conferences 2009

Agenda


          • Racking 19-inch IBM System Units: 520, 550, 560, 570
          • Racking 19-inch IBM I/O Drawers :
             – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
               #5094/96
             – Disk only drawer: #5786, #5886
          • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
          •   IBM Rack Options
          •   IBM Power Distribution Units (PDU)                             #7188, #7109
          •   IBM Rack UPS
          •   IBM Tape and racks
          •   Nuts & bolts
          •   Using different IBM or OEM Racks



43               Racking Your Power System … Without Aspirin                                            © 2009 IBM Corporation




                 STG Technical Conferences 2009
Q: Can I put my Power Systems equipment in a System x™ or
TotalStorage™ 1.8m or 2m enterprise rack instead of a Power
Systems rack? What about vice versa?

 A: Yes, but             The physical rack frame of the 7014-Txx/#055x (Power), 9308 (System x) and 2101
 (TotalStorage) is identical. The equipment will fit into the rack. But there are differences in the rack options offered
 due to different value propositions of each product line. These differences are reflected in different names of the
 same physical feature, different features, different ordering rules, different heights, different prices, different PDUs,
 different options, etc. And the racks have been tested with different combinations of hardware.

 If you want to insert a Power System in a 9308 or 2101; AAS/WTAAS or eConfig does not recognize this and does
 not offer any planning assistance. The customer/sales team must provide the planning expertise. Things to
 consider include:
  - PDUs can be different and support different voltage/amperages. Power cords from server equipment to the PDU is
 probably the same (especially if Power System, System p and System i), but should be checked.
  -Standard IBM manufacturing processes do not insert Power Systems into non-Power Systems rack before
 shipping out.

 Make sure the IBM service organization is aware of what you are doing and agrees IN ADVANCE to support the
 configuration. The best time to resolve such questions is before a service call is needed. Though IBM Service
 should have no problem, there can be implications to airflow (cooling), equipment placement (customer/service
 safety), harmonic vibration, etc depending on what else is installed in the rack. IBM Service has the right to not
 provide support if they feel there are potential safety, functional or reliability concerns.




44               Racking Your Power System … Without Aspirin                                            © 2009 IBM Corporation




                                                                                                                                 22
STG Technical Conferences 2009
Q: Can I put my Power Systems equipment in a System x™
“non-enterprise” rack instead of a Power Systems rack?


  A: Probably, but               The physical rack frame of these racks is not identical. They are usually narrower
  and lighter weight. There are other differences in the rack options offered. These racks have not been tested with
  Power Systems nor with different combinations of hardware likely to have been ordered with the racks.


  Make sure the IBM service organization is aware of what you are doing and agrees IN ADVANCE to support the
  configuration. The best time to resolve such questions is before a service call is needed. Though IBM Service
  should have no problem, there can be implications to airflow (cooling), equipment placement (customer/service
  safety), harmonic vibration, etc depending on what else is installed in the rack. IBM Service has the right to not
  provide support if they feel there are potential safety, functional or reliability concerns.


  Note also that these racks are too narrow for “side pockets” where PDUs can reside without taking up 1 U of space.
  However, these racks are narrow enough to fit on a 2-foot floor tile without overlapping.




45                 Racking Your Power System … Without Aspirin                                                © 2009 IBM Corporation




                   STG Technical Conferences 2009

Q: Can I put my IBM equipment in an OEM rack?

 A: Yes, but….          Recommend contacting IBM Service BEFORE doing this. Though they will
 probably support this configuration, key considerations include:

 Depth:   The IBM 055x & 7014 racks all have a depth of 28 inches between the front and back vertical supports. Other vendors
 may have different depths.
 - POWER6 520/550 has adjustable depth rails, but POWER5 520/550 originally did not but later changed to a rail design which
 was had adjustable depth capability.
 - POWER5 570 is designed for the #0551/3 & 7014 rack. There are important cabling considerations for connecting multiple
 processor drawers together.
 - POWER6 560/570 is a little more flexible for cabling than POWER5 570, but care must be taken to ensure it will work.
 - I/O: Newer I/O drawers come with adjustable depth rails. #0595 adjusts from approximately 26 to 29 inches. #0588 or #0578
 were designed for the IBM #055x 28-inch depth rack and do not fit other depths. #5790 fits inside an enclosure which has rails.
 #7311 enclosure has fixed depth rails. #7307 enclosure has adjustable depth rails. #5802 has adjustable rails depth rails.

 Mounting holes: Other vendors may interpret the EIA 310-D hole standards in a differently than IBM. The vendor may or
 may not have adapters to accommodate the mounting hardware of other vendors. Even the OEM rack (rail) features IBM
 provides use the same mounting hole pattern as the IBM rack rails. THIS CAN BE A REAL HASSLE OR EVEN A SHOW
 STOPPER.

 General:    The 19-inch rack must have the physical strength for what you are planning. Operator/service personnel safety,
 accessibility, cooling, electromagnetic interference, harmonic vibration, etc. must be considered. Because of these
 considerations, it is recommended that IBM Service be consulted in advance. IBM can refuse to service the equipment and
 warranties can be voided if they believe there are likely to be problems. This can even happen after initially accepting the
 configuration if additional information becomes available.

 No Configurator:        Also be aware that if you rack IBM servers outside of an #055x or 7014, AAS/WTAAS or eConfig does not
 offer any planning assistance. The customer/sales team must provide the planning expertise. Things to consider include:
 anti-tip plates, doors with adequate airflow capabilities, PDUs, cable management, weight, etc.



46                 Racking Your Power System … Without Aspirin                                                © 2009 IBM Corporation




                                                                                                                                       23
STG Technical Conferences 2009
Q: What do IBM Service Guidelines Say About non-IBM Racks?

 A: IBM System i5 is designed to be installed in industry-standard EIA racks. The following resources provide details about
 installation in either non-IBM racks or in IBM racks not specifically listed as 'supported' in marketing materials. The customer
 should use these resources, and work with their seller (either IBM or Business Partner) to assess whether the proposed rack is
 acceptable for the proposed purpose, and to order the materials necessary to mount their system in a particular rack. It is
 important to consider that IBM Service's involvement in implementing any solution not specifically supported by IBM's published
 marketing materials is considered a billable service. This includes consultation on implementing solutions involving non-IBM
 racks or IBM racks which are not specifically listed as 'supported' in the marketing materials for the system in question.
 The rack must meet EIA industry standards, and it must meet the technical requirements set out in the eServer Information
 Center (http://publib.boulder.ibm.com/infocenter/eserver/v1r2s/en_US/index.htm) in the Non-IBM Rack Specifications of the
 Planning section of the InfoCenter. It is the customer's responsibility to ensure that these specifications are met. Planning in
 advance, doing one's "homework" and making sure all technical and safety requirements are met are the key to ensuring the
 resulting solution can be maintained safely and, therefore, supported by IBM service.
 The IBM service representative and Field Manager responsible for the account in question should assess the proposed
 scenario based on the information above and based on the customer's assurance that the rack meets EIA industry standards
 and other technical and safety requirements as specified in the Information Center documentation. In addition, the device must
 be mounted using mounting hardware and rails engineered to meet or exceed the specifications for the rails and mounting
 hardware normally provided by IBM for the purpose of mounting the system in a rack.
 It is important to understand that for customer set up systems (CSU) such as the model 520, any IBM installation/set up activity
 related to a CSU device is for fee only. The device is designed/priced for customer set up/installation. So the customer should
 install these CSU devices whether it is installed as a desk-side or rack-mount system, unless the customer has agreed to pay
 IBM a fee to install/set up the system.
 If the customer is willing to pay IBM for a technical assessment of the rack, and technical assistance is required, contact the
 installation planning focal point for the country or area.




47                 Racking Your Power System … Without Aspirin                                                 © 2009 IBM Corporation




                   STG Technical Conferences 2009

Q: What about exiting cables overhead vs below-floor?

 A: Officially all cabling from the rack exists from the bottom, but….
 It’s important to understand that “IBM Support” of a specific configuration can have different a
 meaning to different IBMers depending on who is asking and in what context. The IBM
 Development team would say, “ought to work fine, but we didn’t test and certify an overhead cable
 exit and therefore not supported.” IBM Service organization might hear only the “Development
 didn’t test and doesn’t support” statement.

 Recommend contacting IBM Service BEFORE doing this. Though they will probably support this
 configuration, it’s better to have the discussion before installation. IBM Service is the group who
 will agree to support (or not support) the hardware even if cabled overhead (or not agree).

 So given you understand the above:
 -- There is a removable plate at the top rear of the 7014-T00/T42/B42 and #0551/0553 racks which will
 physically provide a nice exit location for cables out of the top of the rack. The plate was not
 originally designed for this purpose, but it works fine. A service engineer can remove the plate
 (billable time).
 -- All signal-carrying copper cables emit a small amount of radiation (law of physics) unless really
 well shielded. Running cables along the real floor and under the raised floor will reduce overall
 electro-magnetic radiation levels (from small to smaller). Thus going overhead loses some of that
 shielding. Most service organizations would agree it is ok for overhead, but some might not support
 the server configured in this fashion.




48                 Racking Your Power System … Without Aspirin                                                 © 2009 IBM Corporation




                                                                                                                                        24
STG Technical Conferences 2009

Agenda


     • Racking 19-inch IBM System Units: 520, 550, 560, 570
     • Racking 19-inch IBM I/O Drawers :
        – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96,
          #5094/96
        – Disk only drawer: #5786, #5886
     • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m
     •   IBM Rack Options
     •   IBM Power Distribution Units (PDU)              #7188, #7109
     •   IBM Rack UPS
     •   IBM Tape and racks
     •   Nuts & bolts
     •   Using different IBM or OEM Racks



49         Racking Your Power System … Without Aspirin                  © 2009 IBM Corporation




           STG Technical Conferences 2009




     THANKS
     Questions?

                                     P14
                            tions: SM
                      Evalua


50         Racking Your Power System … Without Aspirin                  © 2009 IBM Corporation




                                                                                                 25
STG Technical Conferences 2009

9407-M15 & 9408-M25 Rack-mount & Deskside
POWER6 520 – without unified feature codes

     Order rackmount using                                     Order deskside using
     – #7251 rack-mount specify                                  – #7250 deskside specify
     – #7267 bezel, adjust depth rails,                          – #7224 front door (lockable)




                                               Field conversions
                                               announced Feb 2009




     Order rackmount using                                     Order deskside using
     – #7200 rack-mount specify                                  – #7112 Covers & door (lockable)
     – #7114 bezel, adjust depth rails,

51          Racking Your Power System … Without Aspirin                                    © 2009 IBM Corporation




            STG Technical Conferences 2009                                     2008 July 22 announce

9409-M50 Rack-mount & Deskside
POWER6 550 – without unified feature codes



     Order rackmount using                                     Order deskside using
     – #7229 rack-mount specify                                  – #7226 deskside specify
     – #7268 bezel, adjust depth rails,                          – #7227 front door (lockable)




                                                  No field conversions




     Order rackmount using                                     Order deskside using
     – #7360 rack-mount specify                                  – #7292 Covers & door (lockable)
     – #7146 bezel, adjust depth rails,

52          Racking Your Power System … Without Aspirin                                    © 2009 IBM Corporation




                                                                                                                    26
STG Technical Conferences 2009

POWER5 Model 515/520/525 - Racking Insights
     9405-515, 9406-520, 9406-525




                                                                          4U (4 EIA)



       Ordering from IBM
       • Specify feat code #7884 for rackmount includes
           – fixed depth rails for 28” deep racks (IBM rails are 28” deep)
       • Also specify #7182 (1.9GHz 520)
           – Front black bezel covering front of 520
       • Also specify #7198 adjustable rails
           – along with #7182 to order adjustable rails for 20.5 – 29.5” deep racks
53              Racking Your Power System … Without Aspirin                                 © 2009 IBM Corporation




                STG Technical Conferences 2009

POWER5 515/520/525 Deskside to Rackmount
     9405-515, 9406-520, 9406-525




        Deskside-to-rackmount is an MES order (Customer Set Up)


     • 1.5/1.65GHz 520 MES ordering
        – Convert #7885 to #7884          chargeable, ships fixed 28” depth rails
        – If also want rails which are adjustable and can go in racks deeper than 28”, then ALSO
          order #7198 (additional charge)
     • 1.9GHz 520 MES ordering
        – Convert #7885 to #7182          chargeable, ships fixed 28” depth rails
        – If also want rails which are adjustable and can go in racks deeper than 28”, then ALSO
          order #7198 (additional charge)
54              Racking Your Power System … Without Aspirin                                 © 2009 IBM Corporation




                                                                                                                     27
STG Technical Conferences 2009

POWER5 Model 550 - Racking Insights
     9406-550




                                              4U (4 EIA)


       • #7183 = IBM racking specify
          – Includes adjustable depth rails for 25.5 – 29.25” deep racks



      IBM offers neither a rackmount-to-deskside conversion nor a deskside-to-rackmount conversion

55              Racking Your Power System … Without Aspirin                                © 2009 IBM Corporation




                STG Technical Conferences 2009

Model 570 - Racking Insights
     9406-570, 9406-MMA




                                 4U (4 EIA)
                              Processor drawer

       • All 570 are 19” rackmount only.
         Adjustable depth rails are included
                                                                                   If creating 8-way or 16-
       • 570s bigger than 4-way are multi-                                         way 570, processor
                                                                                   drawers must be
         drawer. This has rack implications,                                       installed adjacent to one
                                                                                   another.
         both IBM and OEM rack.

56              Racking Your Power System … Without Aspirin                                © 2009 IBM Corporation




                                                                                                                    28
STG Technical Conferences 2009

Four/Three Feature Coded Racks
        This chart applies to the POWER5 and to the POWER6 non-unified servers
        (9406, 9407, 9408 and 9409). It changes somewhat with the unified
        POWER6 servers (8203, 8204, 8234, 9117, 9119)




                                                                                                       Withdrawn
                                                                                                       From
                                                                                                       marketing




                       2m                               1.8m                  1.3m                    0.6m
                      (79”)                             (71”)                 (49”)                    (24”)
                      42U                               36U                   25U                      11U
                     #0553                             #0551                 #0555                    #0554

57                    Racking Your Power System … Without Aspirin                                     © 2009 IBM Corporation




                      STG Technical Conferences 2009

0.6 Meter Rack (11U)

            Withdrawn                                  • 11 EIA or 11U
            From                                       • 28-inch depth between vertical supports
                                                       • EIA 310-D mounting hole pattern
            marketing                                     • But square holes, unlike 1.8m or 2m rack

                                                       • Same basic rack (i, p, x), ordered
                                                         differently
                                                          • 7014-S11     System p (also being withdrawn)
                                                          • 9306-110     System x

                                                       • No accessories - base includes:
     WIDTH - exterior                                     • Front lockable doors (No rear door)
         With side panels           518 mm (20.4 in)
         Without side panels        N/A
                                                          • Front filler panels if empty from plant
     DEPTH – interior (rail to
                                    28 in
     rail)
     DEPTH - exterior                                  • Narrower than 1.8 or 2 meter rack
         Front door, no rear door   873 mm (34.4 in)      • PDU placement impacted
         Front & rear doors         No rear door          • Model 570 processor drawer not supported
     HEIGHT                         611 mm (24 in)
     WEIGHT empty                   36 kg (80 lb)
58                    Racking Your Power System … Without Aspirin                                     © 2009 IBM Corporation




                                                                                                                               29
STG Technical Conferences 2009

Ordering IBM Manufacturing Placement

         Without ordering guidance, IBM Manufacturing applies general
         guidelines to place equipment in rack
                 System CECs, I/O drawers, HMC & monitor, UPS, PDU
                 Doesn’t apply to I/O not shipped from the same IBM Plant


         Guidance you can give IBM Manufacturing with proper ordering
           a) Reserve rack space leaves open space in the rack for inserting an
              HMC, HMC monitor or UPS at the customer site (no charge)
           b) Factory integration directs IBM to find a separately ordered HMC,
              HMC monitor or UPS and insert in the 9406 rack before shipping
              (no charge)
           c) Custom rack placement tells IBM Manufacturing exactly where to
              place the components in the rack      (520/550 - modest charge &
              570/595 – no charge)




59                   Racking Your Power System … Without Aspirin                                                                 © 2009 IBM Corporation




                     STG Technical Conferences 2009

Special notices
 This document was developed for IBM offerings in the United States as of the date of publication. IBM may not make these offerings available in
 other countries, and the information is subject to change without notice. Consult your local IBM business contact for information on the IBM
 offerings available in your area.
 Information in this document concerning non-IBM products was obtained from the suppliers of these products or other public sources. Questions
 on the capabilities of non-IBM products should be addressed to the suppliers of those products.
 IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give
 you any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY
 10504-1785 USA.
 All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives
 only.
 The information contained in this document has not been submitted to any formal IBM test and is provided "AS IS" with no warranties or
 guarantees either expressed or implied.
 All examples cited or described in this document are presented as illustrations of the manner in which some IBM products can be used and the
 results that may be achieved. Actual environmental costs and performance characteristics will vary depending on individual client configurations
 and conditions.
 IBM Global Financing offerings are provided through IBM Credit Corporation in the United States and other IBM subsidiaries and divisions
 worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment
 type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal
 without notice.
 IBM is not responsible for printing errors in this document that result in pricing or information inaccuracies.
 All prices shown are IBM's United States suggested list prices and are subject to change without notice; reseller prices may vary.
 IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply.
 Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are
 dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this
 document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally-
 available systems. Some measurements quoted in this document may have been estimated through extrapolation. Users of this document
 should verify the applicable data for their specific environment.



                                                                                                                         Revised September 26, 2006


60                   Racking Your Power System … Without Aspirin                                                                 © 2009 IBM Corporation




                                                                                                                                                          30
STG Technical Conferences 2009

     Special notices (cont.)
IBM, the IBM logo, ibm.com AIX, AIX (logo), AIX 6 (logo), AS/400, BladeCenter, Blue Gene, ClusterProven, DB2, ESCON, i5/OS, i5/OS (logo), IBM Business Partner
(logo), IntelliStation, LoadLeveler, Lotus, Lotus Notes, Notes, Operating System/400, OS/400, PartnerLink, PartnerWorld, PowerPC, pSeries, Rational, RISC
System/6000, RS/6000, THINK, Tivoli, Tivoli (logo), Tivoli Management Environment, WebSphere, xSeries, z/OS, zSeries, AIX 5L, Chiphopper, Chipkill, Cloudscape, DB2
Universal Database, DS4000, DS6000, DS8000, EnergyScale, Enterprise Workload Manager, General Purpose File System, , GPFS, HACMP, HACMP/6000, HASM, IBM
Systems Director Active Energy Manager, iSeries, Micro-Partitioning, POWER, PowerExecutive, PowerVM, PowerVM (logo), PowerHA, Power Architecture, Power
Everywhere, Power Family, POWER Hypervisor, Power Systems, Power Systems (logo), Power Systems Software, Power Systems Software (logo), POWER2,
POWER3, POWER4, POWER4+, POWER5, POWER5+, POWER6, System i, System p, System p5, System Storage, System z, Tivoli Enterprise, TME 10, Workload
Partitions Manager and X-Architecture are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or
both. If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol (® or ™), these symbols indicate U.S.
registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in
other countries. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml

The Power Architecture and Power.org wordmarks and the Power and Power.org logos and related marks are trademarks and service marks licensed by Power.org.
UNIX is a registered trademark of The Open Group in the United States, other countries or both.
Linux is a registered trademark of Linus Torvalds in the United States, other countries or both.
Microsoft, Windows and the Windows logo are registered trademarks of Microsoft Corporation in the United States, other countries or both.
Intel, Itanium, Pentium are registered trademarks and Xeon is a trademark of Intel Corporation or its subsidiaries in the United States, other countries or both.
AMD Opteron is a trademark of Advanced Micro Devices, Inc.
Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries or both.
TPC-C and TPC-H are trademarks of the Transaction Performance Processing Council (TPPC).
SPECint, SPECfp, SPECjbb, SPECweb, SPECjAppServer, SPEC OMP, SPECviewperf, SPECapc, SPEChpc, SPECjvm, SPECmail, SPECimap and SPECsfs are
trademarks of the Standard Performance Evaluation Corp (SPEC).
NetBench is a registered trademark of Ziff Davis Media in the United States, other countries or both.
AltiVec is a trademark of Freescale Semiconductor, Inc.
Cell Broadband Engine is a trademark of Sony Computer Entertainment Inc.
InfiniBand, InfiniBand Trade Association and the InfiniBand design marks are trademarks and/or service marks of the InfiniBand Trade Association.
Other company, product and service names may be trademarks or service marks of others.




                                                                                                                                                                             Revised April 24, 2008


61                              Racking Your Power System … Without Aspirin                                                                                                             © 2009 IBM Corporation




                                STG Technical Conferences 2009

Trademarks
  The following are trademarks of the International Business Machines Corporation in the United States, other countries, or both.

     Not all common law marks used by IBM are listed on this page. Failure of a mark to appear does not mean that IBM does not use the mark nor does it mean that the product is not
     actively marketed or is not significant within its relevant market.
     Those trademarks followed by ® are registered trademarks of IBM in the United States; all others are trademarks or common law marks of IBM in the United States.



      For a complete list of IBM Trademarks, see www.ibm.com/legal/copytrade.shtml:

      *, AS/400®, e business(logo)®, DBE, ESCO, eServer, FICON, IBM®, IBM (logo)®, iSeries®, MVS, OS/390®, pSeries®, RS/6000®, S/30, VM/ESA®, VSE/ESA,
      WebSphere®, xSeries®, z/OS®, zSeries®, z/VM®, System i, System i5, System p, System p5, System x, System z, System z9®, BladeCenter®



  The following are trademarks or registered trademarks of other companies.

     Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries.
     Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom.
     Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
     Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.
     Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel
     Corporation or its subsidiaries in the United States and other countries.
     UNIX is a registered trademark of The Open Group in the United States and other countries.
     Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.
     ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office.
     IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency, which is now part of the Office of Government Commerce.
  * All other products may be trademarks or registered trademarks of their respective companies.

  Notes:
  Performance is in Internal Throughput Rate (ITR) ratio based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput that any user will
  experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed.
  Therefore, no assurance can be given that an individual user will achieve throughput improvements equivalent to the performance ratios stated here.
  IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply.
  All customer examples cited or described in this presentation are presented as illustrations of the manner in which some customers have used IBM products and the results they may have achieved. Actual
  environmental costs and performance characteristics will vary depending on individual customer configurations and conditions.
  This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the information may be subject to change without
  notice. Consult your local IBM business contact for information on the product or services available in your area.
  All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.
  Information about non-IBM products is obtained from the manufacturers of those products or their published announcements. IBM has not tested those products and cannot confirm the performance,
  compatibility, or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.
  Prices subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography.


62                              Racking Your Power System … Without Aspirin                                                                                                             © 2009 IBM Corporation




                                                                                                                                                                                                                 31

Mais conteúdo relacionado

Mais procurados

Q40 - Quad Core Sealed Server
Q40 - Quad Core Sealed ServerQ40 - Quad Core Sealed Server
Q40 - Quad Core Sealed ServerAPMLinked_In
 
Q-series DC Powered Sealed Servers
Q-series DC Powered Sealed ServersQ-series DC Powered Sealed Servers
Q-series DC Powered Sealed Serverstciesielka
 
Rez Shield 79 M Presentation
Rez Shield 79 M PresentationRez Shield 79 M Presentation
Rez Shield 79 M PresentationKaba
 
Kele enclosures catalog
Kele enclosures catalogKele enclosures catalog
Kele enclosures catalogKele, Inc.
 
Rutherford 10-5 Data Sheet
Rutherford 10-5 Data SheetRutherford 10-5 Data Sheet
Rutherford 10-5 Data SheetJMAC Supply
 
AMD 2014 Performance Mobile APUs
AMD 2014 Performance Mobile APUsAMD 2014 Performance Mobile APUs
AMD 2014 Performance Mobile APUsAMD
 
SCRT ISV Product Enablement
SCRT ISV Product EnablementSCRT ISV Product Enablement
SCRT ISV Product EnablementAndrew Sica
 
Datavideo SE-600
Datavideo SE-600Datavideo SE-600
Datavideo SE-600AV ProfShop
 
[Café techno] - Ibm power7 - Les dernières annonces
[Café techno] - Ibm power7 - Les dernières annonces[Café techno] - Ibm power7 - Les dernières annonces
[Café techno] - Ibm power7 - Les dernières annoncesGroupe D.FI
 

Mais procurados (9)

Q40 - Quad Core Sealed Server
Q40 - Quad Core Sealed ServerQ40 - Quad Core Sealed Server
Q40 - Quad Core Sealed Server
 
Q-series DC Powered Sealed Servers
Q-series DC Powered Sealed ServersQ-series DC Powered Sealed Servers
Q-series DC Powered Sealed Servers
 
Rez Shield 79 M Presentation
Rez Shield 79 M PresentationRez Shield 79 M Presentation
Rez Shield 79 M Presentation
 
Kele enclosures catalog
Kele enclosures catalogKele enclosures catalog
Kele enclosures catalog
 
Rutherford 10-5 Data Sheet
Rutherford 10-5 Data SheetRutherford 10-5 Data Sheet
Rutherford 10-5 Data Sheet
 
AMD 2014 Performance Mobile APUs
AMD 2014 Performance Mobile APUsAMD 2014 Performance Mobile APUs
AMD 2014 Performance Mobile APUs
 
SCRT ISV Product Enablement
SCRT ISV Product EnablementSCRT ISV Product Enablement
SCRT ISV Product Enablement
 
Datavideo SE-600
Datavideo SE-600Datavideo SE-600
Datavideo SE-600
 
[Café techno] - Ibm power7 - Les dernières annonces
[Café techno] - Ibm power7 - Les dernières annonces[Café techno] - Ibm power7 - Les dernières annonces
[Café techno] - Ibm power7 - Les dernières annonces
 

Destaque

Ibm power systems facts and features power 8
Ibm power systems facts and features  power 8 Ibm power systems facts and features  power 8
Ibm power systems facts and features power 8 Diego Alberto Tamayo
 
Ak 47 9 2_n premi jeremias soler
Ak 47 9  2_n premi jeremias solerAk 47 9  2_n premi jeremias soler
Ak 47 9 2_n premi jeremias solerBiblioteca Almenar
 
Cloudstack user group meeting in osaka
Cloudstack user group meeting in osakaCloudstack user group meeting in osaka
Cloudstack user group meeting in osakaNaotaka Jay HOTTA
 
Pagerank
PagerankPagerank
PagerankESPOL
 
Chequeo semanal 24 julio
Chequeo semanal 24 julioChequeo semanal 24 julio
Chequeo semanal 24 julioSofy Vilatuña
 
Klant Waardevolle Ketens Volgens Dal Segno
Klant Waardevolle Ketens Volgens Dal SegnoKlant Waardevolle Ketens Volgens Dal Segno
Klant Waardevolle Ketens Volgens Dal Segnoernstsiegert
 
Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...
Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...
Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...Neil Thornton HBA, MA
 
Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...
Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...
Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...Neil Thornton HBA, MA
 

Destaque (20)

Ibm power systems facts and features power 8
Ibm power systems facts and features  power 8 Ibm power systems facts and features  power 8
Ibm power systems facts and features power 8
 
Cpsp competitive analysis
Cpsp competitive analysisCpsp competitive analysis
Cpsp competitive analysis
 
Mr. Quito
Mr. QuitoMr. Quito
Mr. Quito
 
Wsha convention
Wsha conventionWsha convention
Wsha convention
 
Ak 47 9 2_n premi jeremias soler
Ak 47 9  2_n premi jeremias solerAk 47 9  2_n premi jeremias soler
Ak 47 9 2_n premi jeremias soler
 
Cloudstack user group meeting in osaka
Cloudstack user group meeting in osakaCloudstack user group meeting in osaka
Cloudstack user group meeting in osaka
 
Presentacion; felicitat
Presentacion; felicitatPresentacion; felicitat
Presentacion; felicitat
 
Pagerank
PagerankPagerank
Pagerank
 
Chequeo semanal 24 julio
Chequeo semanal 24 julioChequeo semanal 24 julio
Chequeo semanal 24 julio
 
Klant Waardevolle Ketens Volgens Dal Segno
Klant Waardevolle Ketens Volgens Dal SegnoKlant Waardevolle Ketens Volgens Dal Segno
Klant Waardevolle Ketens Volgens Dal Segno
 
Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...
Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...
Change Management, 'What is Working in the Real World.'- HRPA Niagara - Septe...
 
THE 2013 HURRICANE SEASON IS ONLY 5 MONTHS AWAY
THE 2013 HURRICANE SEASON IS ONLY 5 MONTHS AWAYTHE 2013 HURRICANE SEASON IS ONLY 5 MONTHS AWAY
THE 2013 HURRICANE SEASON IS ONLY 5 MONTHS AWAY
 
Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...
Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...
Leading Today's Teams - Cultivating a culture that embraces change - Ontario ...
 
Car Buying
Car BuyingCar Buying
Car Buying
 
THE 2014 OUTBREAK OF EBOLA: UNDERSTANDING DISEASE AND DISASTER RISK AND RISK ...
THE 2014 OUTBREAK OF EBOLA: UNDERSTANDING DISEASE AND DISASTER RISK AND RISK ...THE 2014 OUTBREAK OF EBOLA: UNDERSTANDING DISEASE AND DISASTER RISK AND RISK ...
THE 2014 OUTBREAK OF EBOLA: UNDERSTANDING DISEASE AND DISASTER RISK AND RISK ...
 
India tropical cyclone phalin 12 october 2013
India tropical cyclone phalin  12 october 2013India tropical cyclone phalin  12 october 2013
India tropical cyclone phalin 12 october 2013
 
Llibret La Dona 2009
Llibret  La Dona  2009Llibret  La Dona  2009
Llibret La Dona 2009
 
Lessons learned from past floods in Algeria for strengthened disaster prepare...
Lessons learned from past floods in Algeria for strengthened disaster prepare...Lessons learned from past floods in Algeria for strengthened disaster prepare...
Lessons learned from past floods in Algeria for strengthened disaster prepare...
 
Tornado outbreak devastates American Midwest
Tornado outbreak devastates American MidwestTornado outbreak devastates American Midwest
Tornado outbreak devastates American Midwest
 
Presentació xavier
Presentació xavierPresentació xavier
Presentació xavier
 

Semelhante a Racking Your System

Power Systems 2009 Hardware
Power Systems 2009 HardwarePower Systems 2009 Hardware
Power Systems 2009 HardwareAndrey Klyachkin
 
POWER Systems April 2012
POWER Systems April 2012POWER Systems April 2012
POWER Systems April 2012COMMON Europe
 
HIikvision Mobile DVR 2012
HIikvision Mobile DVR 2012HIikvision Mobile DVR 2012
HIikvision Mobile DVR 2012mos81
 
AMREL 19"/2 Rugged Network Servers
AMREL 19"/2 Rugged Network  ServersAMREL 19"/2 Rugged Network  Servers
AMREL 19"/2 Rugged Network Serversamrelmarcomm
 
Presentation blade center 101
Presentation   blade center 101Presentation   blade center 101
Presentation blade center 101xKinAnx
 
A brief look at ibm mainframe history
A brief look at ibm mainframe historyA brief look at ibm mainframe history
A brief look at ibm mainframe historysivaprasanth rentala
 
1 asr9 k platform architecture
1   asr9 k platform architecture1   asr9 k platform architecture
1 asr9 k platform architectureThanh Hung Quach
 
#IBMEdge: Flash Storage Session
#IBMEdge: Flash Storage Session#IBMEdge: Flash Storage Session
#IBMEdge: Flash Storage SessionBrocade
 
Innodisk at aditech customer meet 2015
Innodisk at aditech customer meet 2015Innodisk at aditech customer meet 2015
Innodisk at aditech customer meet 2015Vilas Fulsundar
 
IBM System Networking Portfolio Update, June 2014
IBM System Networking Portfolio Update, June 2014IBM System Networking Portfolio Update, June 2014
IBM System Networking Portfolio Update, June 2014Angel Villar Garea
 
A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...
A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...
A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...IBM India Smarter Computing
 
Weg with aegis_brochure
Weg with aegis_brochureWeg with aegis_brochure
Weg with aegis_brochureDaniel García
 
Xtw01t4v011311 i dataplex
Xtw01t4v011311 i dataplexXtw01t4v011311 i dataplex
Xtw01t4v011311 i dataplexpgnguyen44
 
G108277 ds8000-resiliency-lagos-v1905c
G108277 ds8000-resiliency-lagos-v1905cG108277 ds8000-resiliency-lagos-v1905c
G108277 ds8000-resiliency-lagos-v1905cTony Pearson
 
The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...
The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...
The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...bsduser071
 
Innovations in the Enterprise Routing & Switching Space
Innovations in the Enterprise Routing & Switching SpaceInnovations in the Enterprise Routing & Switching Space
Innovations in the Enterprise Routing & Switching SpaceCisco Canada
 
SIMATIC S7-1200 Overview
SIMATIC S7-1200 OverviewSIMATIC S7-1200 Overview
SIMATIC S7-1200 OverviewLuis Narvaez
 

Semelhante a Racking Your System (20)

Power Systems 2009 Hardware
Power Systems 2009 HardwarePower Systems 2009 Hardware
Power Systems 2009 Hardware
 
POWER Systems April 2012
POWER Systems April 2012POWER Systems April 2012
POWER Systems April 2012
 
HIikvision Mobile DVR 2012
HIikvision Mobile DVR 2012HIikvision Mobile DVR 2012
HIikvision Mobile DVR 2012
 
AMREL 19"/2 Rugged Network Servers
AMREL 19"/2 Rugged Network  ServersAMREL 19"/2 Rugged Network  Servers
AMREL 19"/2 Rugged Network Servers
 
BladeCenter 101
BladeCenter 101BladeCenter 101
BladeCenter 101
 
Presentation blade center 101
Presentation   blade center 101Presentation   blade center 101
Presentation blade center 101
 
A brief look at ibm mainframe history
A brief look at ibm mainframe historyA brief look at ibm mainframe history
A brief look at ibm mainframe history
 
1 asr9 k platform architecture
1   asr9 k platform architecture1   asr9 k platform architecture
1 asr9 k platform architecture
 
#IBMEdge: Flash Storage Session
#IBMEdge: Flash Storage Session#IBMEdge: Flash Storage Session
#IBMEdge: Flash Storage Session
 
Innodisk at aditech customer meet 2015
Innodisk at aditech customer meet 2015Innodisk at aditech customer meet 2015
Innodisk at aditech customer meet 2015
 
IBM System Networking Portfolio Update, June 2014
IBM System Networking Portfolio Update, June 2014IBM System Networking Portfolio Update, June 2014
IBM System Networking Portfolio Update, June 2014
 
Vortrag nimz-rpg-021110
Vortrag nimz-rpg-021110Vortrag nimz-rpg-021110
Vortrag nimz-rpg-021110
 
A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...
A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...
A z/OS System Programmer’s Guide to Migrating to a New IBM System z9 EC or z9...
 
Weg with aegis_brochure
Weg with aegis_brochureWeg with aegis_brochure
Weg with aegis_brochure
 
Xtw01t4v011311 i dataplex
Xtw01t4v011311 i dataplexXtw01t4v011311 i dataplex
Xtw01t4v011311 i dataplex
 
G108277 ds8000-resiliency-lagos-v1905c
G108277 ds8000-resiliency-lagos-v1905cG108277 ds8000-resiliency-lagos-v1905c
G108277 ds8000-resiliency-lagos-v1905c
 
The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...
The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...
The_New_IBM_z15_A-technical_review_of_the_Processor_Design_New_Features_IO_Ca...
 
Innovations in the Enterprise Routing & Switching Space
Innovations in the Enterprise Routing & Switching SpaceInnovations in the Enterprise Routing & Switching Space
Innovations in the Enterprise Routing & Switching Space
 
SIMATIC S7-1200 Overview
SIMATIC S7-1200 OverviewSIMATIC S7-1200 Overview
SIMATIC S7-1200 Overview
 
Riello idialog-ups-datasheet
Riello idialog-ups-datasheetRiello idialog-ups-datasheet
Riello idialog-ups-datasheet
 

Mais de Andrey Klyachkin

Matching Cisco and System p
Matching Cisco and System pMatching Cisco and System p
Matching Cisco and System pAndrey Klyachkin
 
Multiple Shared Processor Pools In Power Systems
Multiple Shared Processor Pools In Power SystemsMultiple Shared Processor Pools In Power Systems
Multiple Shared Processor Pools In Power SystemsAndrey Klyachkin
 
Buch des jungen Kämpfers mit AIX V6 - Teil 03
Buch des jungen Kämpfers mit AIX V6 - Teil 03Buch des jungen Kämpfers mit AIX V6 - Teil 03
Buch des jungen Kämpfers mit AIX V6 - Teil 03Andrey Klyachkin
 
Buch des jungen Kämpfers mit AIX V6 - Teil 02
Buch des jungen Kämpfers mit AIX V6 - Teil 02Buch des jungen Kämpfers mit AIX V6 - Teil 02
Buch des jungen Kämpfers mit AIX V6 - Teil 02Andrey Klyachkin
 
Buch des jungen Kämpfers mit AIX V6 - Teil 01
Buch des jungen Kämpfers mit AIX V6 - Teil 01Buch des jungen Kämpfers mit AIX V6 - Teil 01
Buch des jungen Kämpfers mit AIX V6 - Teil 01Andrey Klyachkin
 
Power Blades Implementation
Power Blades ImplementationPower Blades Implementation
Power Blades ImplementationAndrey Klyachkin
 
Faster Than A Speeding Disk
Faster Than A Speeding DiskFaster Than A Speeding Disk
Faster Than A Speeding DiskAndrey Klyachkin
 

Mais de Andrey Klyachkin (9)

Matching Cisco and System p
Matching Cisco and System pMatching Cisco and System p
Matching Cisco and System p
 
Multiple Shared Processor Pools In Power Systems
Multiple Shared Processor Pools In Power SystemsMultiple Shared Processor Pools In Power Systems
Multiple Shared Processor Pools In Power Systems
 
Buch des jungen Kämpfers mit AIX V6 - Teil 03
Buch des jungen Kämpfers mit AIX V6 - Teil 03Buch des jungen Kämpfers mit AIX V6 - Teil 03
Buch des jungen Kämpfers mit AIX V6 - Teil 03
 
Buch des jungen Kämpfers mit AIX V6 - Teil 02
Buch des jungen Kämpfers mit AIX V6 - Teil 02Buch des jungen Kämpfers mit AIX V6 - Teil 02
Buch des jungen Kämpfers mit AIX V6 - Teil 02
 
Buch des jungen Kämpfers mit AIX V6 - Teil 01
Buch des jungen Kämpfers mit AIX V6 - Teil 01Buch des jungen Kämpfers mit AIX V6 - Teil 01
Buch des jungen Kämpfers mit AIX V6 - Teil 01
 
Taking Advantage Of COD
Taking Advantage Of CODTaking Advantage Of COD
Taking Advantage Of COD
 
Power Blades Implementation
Power Blades ImplementationPower Blades Implementation
Power Blades Implementation
 
Faster Than A Speeding Disk
Faster Than A Speeding DiskFaster Than A Speeding Disk
Faster Than A Speeding Disk
 
AIX and PowerVM Update
AIX and PowerVM UpdateAIX and PowerVM Update
AIX and PowerVM Update
 

Racking Your System

  • 1. SMP14 Racking your Power System Hardware … Without Aspirin Mark Olson IBM WW Power Systems Product Manager STG Technical Conferences 2009 © 2009 IBM Corporation STG Technical Conferences 2009 Current Hardware Can Be Racked 19-inch System Units 19-inch I/O Drawers Power 520 #5802 (12X DDR I/O) Power 550 #5796, 5714-G30 (12X I/O) Power 560 #5790, 5711-D11 (HSL/RIO I/O) Power 570 #0595, 5711-D20 (HSL/RIO I/O) POWER5 520/515/525 #5294/5296 (HSL/RIO I/O) POWER5 550 #5094/5096 (HSL/RIO I/O) RPQ POWER5 570 #0588 (HSL/RIO I/O) #5786, (SCSI Disk drawer) #5886 (SAS Disk drawer) 7212/7214 (tape/DVD drawer) 2 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 1
  • 2. STG Technical Conferences 2009 Three 19-inch Rack Sizes (Power Systems) “Standard” 19-inch racks 2m 1.8m 1.3m 42U 36U 25U Note the term “standard” can be wildly misleading when looking across vendors. Though the width of 19” between holes in the vertical support posts is standard, many other aspects follow guidelines/standards which are open to considerable differences in interpretation. 3 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 4 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 2
  • 3. STG Technical Conferences 2009 Power 520 Tower & Rack-mount 8203-E4A 4U Conversions announced Feb 2009 Order tower using Order rackmount using – #7112 Covers & door (lockable) – #7200 rack-mount specify – #7114 bezel, adjust depth rails, #7112 #7200 conversion ships hardware, BUT Must also order for rackmount: Must also order for tower: • Ops panel cable #1877 • Ops panel cable #1843 • #7114 rail kit • Non-PDU power cords • Probably PDU power cords • Rack/PDU if needed 5 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Power 550 Rack-mount & Tower 8204-E8A 4U No field conversions Order rackmount using Order tower using – #7360 rack-mount specify – #7292 Covers & door (lockable) – #7146 bezel, adjust depth rails, FYI - The vast majority of Power 550 shipped from IBM are rackmount. Almost zero requests for footprint conversions have been received for either POWER5 550 or POWER6 550. Therefore IBM has not created the ordering/shipping/billing structure to do such a conversion and has no plans at this time to create this structure. 6 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 3
  • 4. STG Technical Conferences 2009 Model 560/570 - Racking Insights 8234-EMA, 9117-MMA 4U (4 EIA) Processor drawer • All 560/570 are 19” rackmount only. Adjustable depth rails are included If creating 2-drawer, 3- • 560/570 bigger than 1 drawer has rack drawer or 4-drawer configuration, processor implications, both for IBM and OEM drawers must be installed adjacent to one racks. another. 7 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 8 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 4
  • 5. STG Technical Conferences 2009 #5802/5877 12X I/O Drawer (for POWER6 servers) 5802 with disk bays 5877 no disk bays #5802/5877 12X I/O Drawer • 4U or 4 EIA • Adjustable depth rails • 10 PCIe slots, 18 or 0 SFF disk bays • 12X attach • PDU optional No #5802-equivalent deskside packaging option available 9 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 #5796 12X I/O Drawer (for POWER6 servers) #7314 Enclosure • 4U or 4 EIA • 1 or 2 5796 per #7314 #5796 #5796 – adjustable depth rails #5796 12X I/O Drawer • Fits in ½ of 4U enclosure • 6 PCI-X DDR slots per 5796 #5796 is System i heritage, but • 12X attach 7314-G30 drawer is essentially equivalent. • PDU optional No #5796-equivalent deskside packaging option available 10 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 5
  • 6. STG Technical Conferences 2009 #5790 I/O Drawer #7307 Enclosure • 4U or 4 EIA #5790 #5790 • 1 or 2 5790 per #7311/7307 – adjustable depth rails – Earlier #7311 enclosure has fixed depth rails #5790 I/O Drawer • Fits in ½ of 4U enclosure • 6 PCI-X slots per 5790 #5790 is System i heritage, but • HSL/RIO attach 7311-D11 drawer is nearly • PDU optional equivalent No #5790-equivalent deskside packaging option 11 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 #0595 I/O Drawer withdrawn from marketing Aug 2009 #0595 is System i heritage, but 7311-D20 drawer is nearly equivalent, but only 4U #0595 • 5U or 5 EIA • 7 PCI-X slots and 12 disk bays • HSL/RIO attach • PDU optional • Adjustable depth rails included #0595 #5095 Rackmount to deskside (or vice versa) conversions not available 12 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 6
  • 7. STG Technical Conferences 2009 #0588 I/O Drawer Withdrawn from marketing mid 2006 #0588 • 8U or 8 EIA • 14 PCI-X slots and 0 disk bays • HSL/RIO attach • PDU required • Fixed depth rails included – Adjustable rails not available • Previous generation = #0578 #5088 #0588 #5094 Rackmount to deskside (or vice versa) conversions not available 13 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Racked I/O Tower Withdrawn from marketing May 2009 #5294/5296 • 36U 1.8m rack • Total 28 PCI-X slots • Total 90 (#5294) or 0 (#5296) disk bays • HSL/RIO attach • PDU not used • Really two #5094/5096s installed inside a 1.8m rack and ordered as just #5294/5296 #8294 Same thing as 5294, but for 595 #5079 Same thing, but older generation #5074 14 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 7
  • 8. STG Technical Conferences 2009 Single #5094/5096 I/O Tower in a Rack Withdrawn from marketing May 2009 • Chargeable RPQ 847215 Can put • IBM Manufacturing Plant only. 520/525, Not installable at customer site. 550, 570, I/O, etc – Weight of #5094/5096 prohibits here this being done at customer site • For model 520/525/550/570/595 & 800/810/825/870/890 Rack • Once done, no IBM structure in 36U #0551 42U #0553 place to remove #5094 from rack #5094 14 PCI-X slots and 15 + opt 30 disk slots #5094 uses 18U of rack space 15 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 #5786 EXP24 SCSI Disk Drawer SCSI disk withdrawn from marketing Aug 2009 #5786 is System i heritage, but 7031-D24 drawer is equivalent #5786 • 4U or 4 EIA • 24 3.5” disk bays and 0 PCI-X slots – 12 slots in front, 12 slots in back – 4 disk slot enablers in back • PDU optional • Adjustable depth rails included #5787 Tower withdrawn #5786 from marketing in 2008 Rackmount to tower (or vice versa) conversions not available 16 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 8
  • 9. STG Technical Conferences 2009 EXP 12S SAS Disk Drawer #5886 • 2U or 2EIA disk drawer • 12 SAS 3.5” disk bays and 0 PCI slots per drawer • Adjustable depth rails included • Dual power supplies (two power cords) • Rack only …. No tower option 17 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 18 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 9
  • 10. STG Technical Conferences 2009 Power Systems Racking System i Feature coded racks Power Systems (#055x) Feature coded & machine type/model (#055x & 7014-xxx) • Use 7014-xxx if ordering a new server. Can order along with server MES order if don’t need integrated at IBM plant with MES. • Use #055x if ordering as MES. IBM System p plan can integrate with other I/O Machine type/model drawer or system upgrade MES on the same order. (7014-xxx) Note: in 2009 maintenance pricing for #0551/0553/0554/0555 on POWER6 8203/8204/8234/9117/91119 was added to make it consistent with maintenance pricing on 7014 racks. 19 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Four/Three Power Systems Racks 7014-T42 #0553 7014-T00 7014-B42 #0551 7014-S25 7014-S11 #0555* #0554 Withdrawn From marketing 2m 1.8m 1.3m 0.6m (79”) (71”) (49”) (24”) 42U 36U 25U 11U #0553 #0551 #0555 #0554 20 Racking Your Power System … Without Aspirin * not orderable as #0555 for most servers © 2009 IBM Corporation 10
  • 11. STG Technical Conferences 2009 2 Meter Rack (42U) • 42 EIA or 42U • 28-inch depth between vertical supports • EIA 310-D mounting hole pattern • Frame is 36U rack with 6U extension • Same basic rack (i, p, TS), ordered differently • #0553 Power Systems MES & System i • 7014-T42 Power Systems & System p • 7014-B42 for BladeCenter • 9308-42S/4P_ System x • 2101-N42 TotalStorage WIDTH - exterior • Different rack accessories offered between #055x, 7104, With side panels 644 mm (25.4 in) 9308 Without side panels 623 mm (24.5 in) DEPTH – interior (rail to rail) 28 in DEPTH - exterior • 19-inch, industry standard rack. BUT other Rear door only (front trim kit) 1042 mm (41.0 in) vendors’ depth and hole patterns can vary Regular front & rear doors 1098 mm (43.3 in) HEIGHT 2015 mm (79.3 in) WEIGHT empty 261 kg (575 lb) 21 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 1.8 Meter Rack (36U) • 36 EIA or 36U • 28-inch depth between vertical supports • EIA 310-D mounting hole pattern • Same basic rack (i, p, TS), ordered differently • #0551 Power Systems MES & System i • 7014-T00 Power Systems & System p • 2101-200, -N00 TotalStorage • n/a System x • Different rack accessories offered between #055x, 7104, WIDTH - exterior & 2101 With side panels 644 mm (25.4 in) Without side panels 623 mm (24.5 in) • 19-inch, industry standard rack. BUT other DEPTH – interior (rail to rail) 28 in DEPTH - exterior vendors’ depth and hole patterns can vary Rear door only (front trim kit) 1042 mm (41.0 in) Regular front & rear doors 1098 mm (43.3 in) HEIGHT 1804 mm (71.0 in) WEIGHT empty 244 kg (535 lb) 22 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 11
  • 12. STG Technical Conferences 2009 1.3 Meter Rack (25U) • 25 EIA or 25U • 28-inch depth between vertical supports • EIA 310-D mounting hole pattern • But square holes, unlike 1.8m or 2m rack • Same basic rack (i, p, x), ordered differently • #0555 System i, feature code • 7014-S25 System p • 9308-2SX System x • No accessories - base includes: • Front & rear lockable doors WIDTH - exterior • Front filler panels if empty from plant With side panels 610 mm (24.0 in) Without side panels 590 mm (23.2 in) • Narrower than 1.8 or 2 meter rack DEPTH – interior (rail to rail) 28 in • PDU placement impacted DEPTH - exterior • Model 570 processor drawer restriction Regular front & rear doors 1000 mm (39.4 in) HEIGHT 1240 mm (49 in) WEIGHT empty 102 kg (221 lb) 23 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 24 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 12
  • 13. STG Technical Conferences 2009 42U/36U Rack Options (2m/1.8m) Base Definition Includes 7014-T42/T00 #0553/0551 Perforated rear door* Perforated rear door* No side panels (optional) Side panels Front filler panes (if Front filler panes (if space empty when shipped) space empty when shipped) One PDU (rest optional) No PDU (all optional) Choose #9188 or #5889 Anti-tip plate Anti-tip plate 7014-B42 basically the same as 7014-T42 but all PDU optional * regular rear door not shipped if acoustic doors option ordered 25 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 42U/36U Rack Options Must Choose: Trim Kit or Front Door Regular Acoustic Trim kit Front door Front door* #6246/6247 #6068/6069 #6248/6249 * Acoustic doors feature ships both front & back door Easy access Perforated steel ~6 dB(A) quieter Good visibility Security option: door Security option: door lock & side panel lock & side panel lock #6580 lock #6580 26 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 13
  • 14. STG Technical Conferences 2009 42U/36U Racks Other Options • Side Panel #6098 for 7014 • Suite Attach #7780/7840 for server (existing), #6104/6086 for 7014 (new or existing) • Attaches multiple racks of same size, side-to-side • Remove side panels – connect rack frames • Additional stability • Ruggedized Rack #7841 for server (existing), #6080 for 7014 (new or existing) • Allows bolting rack to floor and additional rack strengthening • Usually considered for earthquake zones • Spare front filler panels #0599 server feat code • Helps maintain proper airflow (and looks better) • Package of (3) 1U and (1) 3U snap-on/off black filler panels • Rack extender #6257 42U 7014 • Adds 20” depth for cable management of InfiniBand switches • Shelf • Not ordered as a feature of 7014 or of server • Ordered as feature of the I/O unit which will sit on the shelf, example: some tape drives 27 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 42U/36U/25U Rack Option Rack Modem Tray #6586 • 1U tray for 19” rack • Holds up to two external modems …. This is NOT a shelf • Convenient for external modems of – rackmount HMC – system • Also supported in 25U and 11U racks Tray with modem installed 28 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 14
  • 15. STG Technical Conferences 2009 “Cool Blue” Rear Door Option #6858 Rear Door Heat Exchanger (RDX) • Option for the 7014-T42 2m rack – Not an orderable feature for #0553 – though would physically work • Water cooled rear door removes heat from exhaust air flow. • Can help eliminate hot spots from computer room. • Can help avoid adding more air conditioning. 29 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 30 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 15
  • 16. STG Technical Conferences 2009 #7188 Power Distribution Unit (PDU) • #7188 PDU • Like a power strip on massive steroids • 12 outlets per PDU (six circuit breakers – 2 outlets per breaker) • Up to 48 amps per PDU (depends on power cord from PDU to wall), up to 15 amps per breaker & 10 amps per outlet • PDU power cords (equipment to PDU) #1422 or #6458 IEC 320 C13/C14 PDU Cord connects PDU to many racked devices. # 6459 or #6664 right angle PDU cord used for #5790 In 7014-T00 or T42 rack, first Other power cords connect the PDU to the “wall/UPS” power. PDU can be no charge #9188 31 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 #7188 Power Distribution Unit (PDU) • Placed horizontally, require 1U space • Up to four #7188 can be placed vertically in “side pockets” of 1.8 or 2m rack and use zero U space. (note eConfig doesn’t track the horizontal PDUs) Drawer • For power redundancy, recommend • Two PDU per rack for equipment with dual power cords • Plug the equipment with dual power cords into different PDUs • Plug the PDUs into different power sources See planning web site for details http://publib.boulder.ibm.com/infocenter/eserver/v1r2s/e n_US/index.htm?info/iphad/f0551_pdu.htm 32 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 16
  • 17. STG Technical Conferences 2009 #7109 Intelligent PDU+ • Physically/electrically very much like #7188 PDU • #7109 provides continuous power usage data. Data sent to PC attached via Ethernet connection • PC running Active Energy Manager can monitor / display information. In 7014-T00 or T42 rack, first PDU can be partial charge #5889 33 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 #7188 vs #7109 PDU Comparison Newer #7188 PDU #7109 PDU+ 12 client usable IEC 320-C13 outlets Yes Yes 200-240 Volts AC, 1-phase Yes Yes 10 Amps per outlet, 16 Amps per pair of outlets Yes Yes Side pocket mount #0551, #0553 racks Yes Yes Horizontal mount taking 1U Yes Yes Height/Width: 43.9mm(1.73 in) / 447mm(17.6 in) Yes Yes Supported on model 5xx & 8xx systems Yes Yes i5/OS release independent Yes Yes Depth 232mm (9.13in) 350mm (13.8in) Continuously monitors power usage by outlet No Yes Ethernet connection for sending usage data No Yes Other PDUs can be ordered from IBM, but not as part of feature code racks 34 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 17
  • 18. STG Technical Conferences 2009 Additional PDU Points • 7014-B42 has a couple additional PDU options designed to support BladeCenter options • System x also has additional PDU offerings. • Temperature/Humidity probe is supported on System x equivalent of #7109 PDU. Being considered for 7014 racks. Demand TBD. Thus future support TBD. 35 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Uninterruptible Power Supply (UPS) 9910 UPS rack solutions offered through IBM Model U (EIA) U (EIA) extra battery UPS modules 9910-E33 2U 2U each (max qty 4) 9910-E50 3U 3U each (max qty 4) 9910-E65 3U 3U each (max qty 2) 9910-E82 6U 3U each (max qty 4) 9910-E83 6U 3U each (max qty 4) For details see: http://www.powerware.com/ibm Details you’ll want to review on Powerware site include Watts available, number of power receptacles provided on UPS, PDU needed or not, etc Until January 2008, used “Pxx” models. Pxx and Exx models have same specifications (wattage, EIA, extra battery) 36 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 18
  • 19. STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 37 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Tape/Optical Rack Enclosure Picture is of 7212 Functionally equivalent to tape/optical drives sitting on rack shelf (see next slide) … but rack optimized (space, power, cooling) • For SCSI: 7212 – 103 (newer) or 7212 – 102 (earlier) • 1 U rack enclosure which holds up to 2 drives in 19-inch rack – QIC 30GB or 50GB, VXA- 2 or 320, 4mm, DVD, LTO-2 • Adjustable depth rails -- 27 to 30.5 inch • For SAS: 7214 – 1U2 • 1 U rack enclosure which holds up to 2 drives in 19-inch rack – DAT72, DAT160,LTO-4, DVD • Adjustable depth rails 38 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 19
  • 20. STG Technical Conferences 2009 Tape/Optical Rack Kit (Shelf) The following drives can sit on a 19” rack shelf which is ordered as feature code #8723 of the drive (device not the system). 7207-122 4GB QIC tape drive 7207-330 30GB QIC tape drive 7208-345 60GB 8mm tape drive 7206-336 36GB 4mm tape drive 7210-025 & -030 DVD-RAM drive 358x LTO tape not listed here All of the above drives have: Width 250mm / 9.8in Height 55mm / 2.2in 39 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 LTO and Enterprise Tape Library Rack Mounting Options LTO Tape Libraries – all are full rack width TS3100 3573 L2U (also HVEC models) Library with single drive and 24 cartridge slots, 2 EIA Rack mount kit is 3573 feat code #7002, rack power cord is 3573 feat code #9848 TS3200 3573 L4U (also HVEC models) Library with 1 or 2 drives and 48 cartridge slots, 4 EIA Rack mount kit is 3573 feat code #7002, rack power cord is 3573 feat code #9848 Specify Qty:2 of feat code #9848 if select optional additional power supply TS3310 3576 L5B Library base unit with 1 or 2 drives and 36 cartridge slots, 5 EIA 3576 L5B + (1) E9U Library base and one expansion, up to 6 drives, 128 cartridge slots, 14 EIA 3576 L5B + (2) E9U Library base and two expansions, up to 10 drives, 218 cartridge slots, 23 EIA 3576 L5B + (3) E9U Library base and three expansions, up to 14 drives, 310 cartridge slots, 32 EIA 3576 L5B + (4) E9U Library base and four expansions, up to 18 drives, 402 cartridge slots, 41 EIA A single rack mount kit 3576 feat code #7003 supports the L5B and all attached E9U’s. Specify one rack power cord 3576 feat code #9848 in each unit (base and expansions). 3582 L23 Library with 1 or 2 drives and 24 cartridge slots, 4 EIA Rack mount kit is 3582 feat code #7003 3583 L18, L36, L72 Library with up to 6 drives and 72 cartridge slots, 14 EIA Rack mount kit is 3583 feat code #8006 Enterprise Tape Library – full rack width TS3400 3577 L5U Library with 1 or 2 TS1120 (3592 E05) drives and 18 cartridge slots, 5 EIA Rack mount kit is 3577 feat code #7004 Author thanks Brannen Proctor for this foil. 40 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 20
  • 21. STG Technical Conferences 2009 LTO and Enterprise Tape Drive Rack Mounting Options LTO Tape Drives and Autoloaders (external attachment – not the LTO-2 drive which goes inside the 520/550 CEC) 3580 H11,H13,H23,L11,L13,L23 two units can sit side-by-side on same shelf 4 EIA = unit (14.6 cm (5.75 in)) + shelf (.7 in) Rack shelf is 3580 feat code #8723 3580 L33, L3H, H3L, H3S, L43, S43, H4S only one unit per shelf (width = 25 cm (9.85 in)) 4 EIA = unit (12 cm (4.75 in)) + shelf (.7 in) Rack shelf is 3580 feat code #7003 3581 F28,L38, F38,L38, F3H, L3H 2 EIA = unit (8.9 cm (3.5 in)) shelf not required one unit per 2U Rack mount kit is 3581 feat code #7003 3581 H17, L17, H13, L13, H23, L23 two units can sit side-by-side on same shelf 5 EIA = unit (19 cm (7.48 in)) + shelf (.7 in) Rack shelf is 3581 feat code #7003 Enterprise Tape Drives and Autoloaders 3590 B11, E11, H11 (rack mount autoloader) 12 EIA for the shelf/cabinet(s) to hold 1 or 2 drives 3592 J1A, E05 TS1120 (rack mount drive only, no autoloader) 10 EIA for the shelf/cabinet(s) to hold 1 to 4 drives 41 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 “Nuts & Bolts” “Cage nut” or “nut box” or “grommet” 6 mm bolt 5 mm bolt Cable hooks Handy things to have when installing • ratchet • power screw driver/drill • flash light – head lamp best • screw drivers • spare nuts/bolts cable ties • knife, tie cutters 42 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 21
  • 22. STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 43 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Q: Can I put my Power Systems equipment in a System x™ or TotalStorage™ 1.8m or 2m enterprise rack instead of a Power Systems rack? What about vice versa? A: Yes, but The physical rack frame of the 7014-Txx/#055x (Power), 9308 (System x) and 2101 (TotalStorage) is identical. The equipment will fit into the rack. But there are differences in the rack options offered due to different value propositions of each product line. These differences are reflected in different names of the same physical feature, different features, different ordering rules, different heights, different prices, different PDUs, different options, etc. And the racks have been tested with different combinations of hardware. If you want to insert a Power System in a 9308 or 2101; AAS/WTAAS or eConfig does not recognize this and does not offer any planning assistance. The customer/sales team must provide the planning expertise. Things to consider include: - PDUs can be different and support different voltage/amperages. Power cords from server equipment to the PDU is probably the same (especially if Power System, System p and System i), but should be checked. -Standard IBM manufacturing processes do not insert Power Systems into non-Power Systems rack before shipping out. Make sure the IBM service organization is aware of what you are doing and agrees IN ADVANCE to support the configuration. The best time to resolve such questions is before a service call is needed. Though IBM Service should have no problem, there can be implications to airflow (cooling), equipment placement (customer/service safety), harmonic vibration, etc depending on what else is installed in the rack. IBM Service has the right to not provide support if they feel there are potential safety, functional or reliability concerns. 44 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 22
  • 23. STG Technical Conferences 2009 Q: Can I put my Power Systems equipment in a System x™ “non-enterprise” rack instead of a Power Systems rack? A: Probably, but The physical rack frame of these racks is not identical. They are usually narrower and lighter weight. There are other differences in the rack options offered. These racks have not been tested with Power Systems nor with different combinations of hardware likely to have been ordered with the racks. Make sure the IBM service organization is aware of what you are doing and agrees IN ADVANCE to support the configuration. The best time to resolve such questions is before a service call is needed. Though IBM Service should have no problem, there can be implications to airflow (cooling), equipment placement (customer/service safety), harmonic vibration, etc depending on what else is installed in the rack. IBM Service has the right to not provide support if they feel there are potential safety, functional or reliability concerns. Note also that these racks are too narrow for “side pockets” where PDUs can reside without taking up 1 U of space. However, these racks are narrow enough to fit on a 2-foot floor tile without overlapping. 45 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Q: Can I put my IBM equipment in an OEM rack? A: Yes, but…. Recommend contacting IBM Service BEFORE doing this. Though they will probably support this configuration, key considerations include: Depth: The IBM 055x & 7014 racks all have a depth of 28 inches between the front and back vertical supports. Other vendors may have different depths. - POWER6 520/550 has adjustable depth rails, but POWER5 520/550 originally did not but later changed to a rail design which was had adjustable depth capability. - POWER5 570 is designed for the #0551/3 & 7014 rack. There are important cabling considerations for connecting multiple processor drawers together. - POWER6 560/570 is a little more flexible for cabling than POWER5 570, but care must be taken to ensure it will work. - I/O: Newer I/O drawers come with adjustable depth rails. #0595 adjusts from approximately 26 to 29 inches. #0588 or #0578 were designed for the IBM #055x 28-inch depth rack and do not fit other depths. #5790 fits inside an enclosure which has rails. #7311 enclosure has fixed depth rails. #7307 enclosure has adjustable depth rails. #5802 has adjustable rails depth rails. Mounting holes: Other vendors may interpret the EIA 310-D hole standards in a differently than IBM. The vendor may or may not have adapters to accommodate the mounting hardware of other vendors. Even the OEM rack (rail) features IBM provides use the same mounting hole pattern as the IBM rack rails. THIS CAN BE A REAL HASSLE OR EVEN A SHOW STOPPER. General: The 19-inch rack must have the physical strength for what you are planning. Operator/service personnel safety, accessibility, cooling, electromagnetic interference, harmonic vibration, etc. must be considered. Because of these considerations, it is recommended that IBM Service be consulted in advance. IBM can refuse to service the equipment and warranties can be voided if they believe there are likely to be problems. This can even happen after initially accepting the configuration if additional information becomes available. No Configurator: Also be aware that if you rack IBM servers outside of an #055x or 7014, AAS/WTAAS or eConfig does not offer any planning assistance. The customer/sales team must provide the planning expertise. Things to consider include: anti-tip plates, doors with adequate airflow capabilities, PDUs, cable management, weight, etc. 46 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 23
  • 24. STG Technical Conferences 2009 Q: What do IBM Service Guidelines Say About non-IBM Racks? A: IBM System i5 is designed to be installed in industry-standard EIA racks. The following resources provide details about installation in either non-IBM racks or in IBM racks not specifically listed as 'supported' in marketing materials. The customer should use these resources, and work with their seller (either IBM or Business Partner) to assess whether the proposed rack is acceptable for the proposed purpose, and to order the materials necessary to mount their system in a particular rack. It is important to consider that IBM Service's involvement in implementing any solution not specifically supported by IBM's published marketing materials is considered a billable service. This includes consultation on implementing solutions involving non-IBM racks or IBM racks which are not specifically listed as 'supported' in the marketing materials for the system in question. The rack must meet EIA industry standards, and it must meet the technical requirements set out in the eServer Information Center (http://publib.boulder.ibm.com/infocenter/eserver/v1r2s/en_US/index.htm) in the Non-IBM Rack Specifications of the Planning section of the InfoCenter. It is the customer's responsibility to ensure that these specifications are met. Planning in advance, doing one's "homework" and making sure all technical and safety requirements are met are the key to ensuring the resulting solution can be maintained safely and, therefore, supported by IBM service. The IBM service representative and Field Manager responsible for the account in question should assess the proposed scenario based on the information above and based on the customer's assurance that the rack meets EIA industry standards and other technical and safety requirements as specified in the Information Center documentation. In addition, the device must be mounted using mounting hardware and rails engineered to meet or exceed the specifications for the rails and mounting hardware normally provided by IBM for the purpose of mounting the system in a rack. It is important to understand that for customer set up systems (CSU) such as the model 520, any IBM installation/set up activity related to a CSU device is for fee only. The device is designed/priced for customer set up/installation. So the customer should install these CSU devices whether it is installed as a desk-side or rack-mount system, unless the customer has agreed to pay IBM a fee to install/set up the system. If the customer is willing to pay IBM for a technical assessment of the rack, and technical assistance is required, contact the installation planning focal point for the country or area. 47 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Q: What about exiting cables overhead vs below-floor? A: Officially all cabling from the rack exists from the bottom, but…. It’s important to understand that “IBM Support” of a specific configuration can have different a meaning to different IBMers depending on who is asking and in what context. The IBM Development team would say, “ought to work fine, but we didn’t test and certify an overhead cable exit and therefore not supported.” IBM Service organization might hear only the “Development didn’t test and doesn’t support” statement. Recommend contacting IBM Service BEFORE doing this. Though they will probably support this configuration, it’s better to have the discussion before installation. IBM Service is the group who will agree to support (or not support) the hardware even if cabled overhead (or not agree). So given you understand the above: -- There is a removable plate at the top rear of the 7014-T00/T42/B42 and #0551/0553 racks which will physically provide a nice exit location for cables out of the top of the rack. The plate was not originally designed for this purpose, but it works fine. A service engineer can remove the plate (billable time). -- All signal-carrying copper cables emit a small amount of radiation (law of physics) unless really well shielded. Running cables along the real floor and under the raised floor will reduce overall electro-magnetic radiation levels (from small to smaller). Thus going overhead loses some of that shielding. Most service organizations would agree it is ok for overhead, but some might not support the server configured in this fashion. 48 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 24
  • 25. STG Technical Conferences 2009 Agenda • Racking 19-inch IBM System Units: 520, 550, 560, 570 • Racking 19-inch IBM I/O Drawers : – With PCI slots: #5802, #5790, #5796, #0595, #0588, #5294/96, #5094/96 – Disk only drawer: #5786, #5886 • IBM Power System 19-inch Racks 1.8m, 2m, 1.3m • IBM Rack Options • IBM Power Distribution Units (PDU) #7188, #7109 • IBM Rack UPS • IBM Tape and racks • Nuts & bolts • Using different IBM or OEM Racks 49 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 THANKS Questions? P14 tions: SM Evalua 50 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 25
  • 26. STG Technical Conferences 2009 9407-M15 & 9408-M25 Rack-mount & Deskside POWER6 520 – without unified feature codes Order rackmount using Order deskside using – #7251 rack-mount specify – #7250 deskside specify – #7267 bezel, adjust depth rails, – #7224 front door (lockable) Field conversions announced Feb 2009 Order rackmount using Order deskside using – #7200 rack-mount specify – #7112 Covers & door (lockable) – #7114 bezel, adjust depth rails, 51 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 2008 July 22 announce 9409-M50 Rack-mount & Deskside POWER6 550 – without unified feature codes Order rackmount using Order deskside using – #7229 rack-mount specify – #7226 deskside specify – #7268 bezel, adjust depth rails, – #7227 front door (lockable) No field conversions Order rackmount using Order deskside using – #7360 rack-mount specify – #7292 Covers & door (lockable) – #7146 bezel, adjust depth rails, 52 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 26
  • 27. STG Technical Conferences 2009 POWER5 Model 515/520/525 - Racking Insights 9405-515, 9406-520, 9406-525 4U (4 EIA) Ordering from IBM • Specify feat code #7884 for rackmount includes – fixed depth rails for 28” deep racks (IBM rails are 28” deep) • Also specify #7182 (1.9GHz 520) – Front black bezel covering front of 520 • Also specify #7198 adjustable rails – along with #7182 to order adjustable rails for 20.5 – 29.5” deep racks 53 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 POWER5 515/520/525 Deskside to Rackmount 9405-515, 9406-520, 9406-525 Deskside-to-rackmount is an MES order (Customer Set Up) • 1.5/1.65GHz 520 MES ordering – Convert #7885 to #7884 chargeable, ships fixed 28” depth rails – If also want rails which are adjustable and can go in racks deeper than 28”, then ALSO order #7198 (additional charge) • 1.9GHz 520 MES ordering – Convert #7885 to #7182 chargeable, ships fixed 28” depth rails – If also want rails which are adjustable and can go in racks deeper than 28”, then ALSO order #7198 (additional charge) 54 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 27
  • 28. STG Technical Conferences 2009 POWER5 Model 550 - Racking Insights 9406-550 4U (4 EIA) • #7183 = IBM racking specify – Includes adjustable depth rails for 25.5 – 29.25” deep racks IBM offers neither a rackmount-to-deskside conversion nor a deskside-to-rackmount conversion 55 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Model 570 - Racking Insights 9406-570, 9406-MMA 4U (4 EIA) Processor drawer • All 570 are 19” rackmount only. Adjustable depth rails are included If creating 8-way or 16- • 570s bigger than 4-way are multi- way 570, processor drawers must be drawer. This has rack implications, installed adjacent to one another. both IBM and OEM rack. 56 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 28
  • 29. STG Technical Conferences 2009 Four/Three Feature Coded Racks This chart applies to the POWER5 and to the POWER6 non-unified servers (9406, 9407, 9408 and 9409). It changes somewhat with the unified POWER6 servers (8203, 8204, 8234, 9117, 9119) Withdrawn From marketing 2m 1.8m 1.3m 0.6m (79”) (71”) (49”) (24”) 42U 36U 25U 11U #0553 #0551 #0555 #0554 57 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 0.6 Meter Rack (11U) Withdrawn • 11 EIA or 11U From • 28-inch depth between vertical supports • EIA 310-D mounting hole pattern marketing • But square holes, unlike 1.8m or 2m rack • Same basic rack (i, p, x), ordered differently • 7014-S11 System p (also being withdrawn) • 9306-110 System x • No accessories - base includes: WIDTH - exterior • Front lockable doors (No rear door) With side panels 518 mm (20.4 in) Without side panels N/A • Front filler panels if empty from plant DEPTH – interior (rail to 28 in rail) DEPTH - exterior • Narrower than 1.8 or 2 meter rack Front door, no rear door 873 mm (34.4 in) • PDU placement impacted Front & rear doors No rear door • Model 570 processor drawer not supported HEIGHT 611 mm (24 in) WEIGHT empty 36 kg (80 lb) 58 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 29
  • 30. STG Technical Conferences 2009 Ordering IBM Manufacturing Placement Without ordering guidance, IBM Manufacturing applies general guidelines to place equipment in rack System CECs, I/O drawers, HMC & monitor, UPS, PDU Doesn’t apply to I/O not shipped from the same IBM Plant Guidance you can give IBM Manufacturing with proper ordering a) Reserve rack space leaves open space in the rack for inserting an HMC, HMC monitor or UPS at the customer site (no charge) b) Factory integration directs IBM to find a separately ordered HMC, HMC monitor or UPS and insert in the 9406 rack before shipping (no charge) c) Custom rack placement tells IBM Manufacturing exactly where to place the components in the rack (520/550 - modest charge & 570/595 – no charge) 59 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Special notices This document was developed for IBM offerings in the United States as of the date of publication. IBM may not make these offerings available in other countries, and the information is subject to change without notice. Consult your local IBM business contact for information on the IBM offerings available in your area. Information in this document concerning non-IBM products was obtained from the suppliers of these products or other public sources. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY 10504-1785 USA. All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. The information contained in this document has not been submitted to any formal IBM test and is provided "AS IS" with no warranties or guarantees either expressed or implied. All examples cited or described in this document are presented as illustrations of the manner in which some IBM products can be used and the results that may be achieved. Actual environmental costs and performance characteristics will vary depending on individual client configurations and conditions. IBM Global Financing offerings are provided through IBM Credit Corporation in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice. IBM is not responsible for printing errors in this document that result in pricing or information inaccuracies. All prices shown are IBM's United States suggested list prices and are subject to change without notice; reseller prices may vary. IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply. Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally- available systems. Some measurements quoted in this document may have been estimated through extrapolation. Users of this document should verify the applicable data for their specific environment. Revised September 26, 2006 60 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 30
  • 31. STG Technical Conferences 2009 Special notices (cont.) IBM, the IBM logo, ibm.com AIX, AIX (logo), AIX 6 (logo), AS/400, BladeCenter, Blue Gene, ClusterProven, DB2, ESCON, i5/OS, i5/OS (logo), IBM Business Partner (logo), IntelliStation, LoadLeveler, Lotus, Lotus Notes, Notes, Operating System/400, OS/400, PartnerLink, PartnerWorld, PowerPC, pSeries, Rational, RISC System/6000, RS/6000, THINK, Tivoli, Tivoli (logo), Tivoli Management Environment, WebSphere, xSeries, z/OS, zSeries, AIX 5L, Chiphopper, Chipkill, Cloudscape, DB2 Universal Database, DS4000, DS6000, DS8000, EnergyScale, Enterprise Workload Manager, General Purpose File System, , GPFS, HACMP, HACMP/6000, HASM, IBM Systems Director Active Energy Manager, iSeries, Micro-Partitioning, POWER, PowerExecutive, PowerVM, PowerVM (logo), PowerHA, Power Architecture, Power Everywhere, Power Family, POWER Hypervisor, Power Systems, Power Systems (logo), Power Systems Software, Power Systems Software (logo), POWER2, POWER3, POWER4, POWER4+, POWER5, POWER5+, POWER6, System i, System p, System p5, System Storage, System z, Tivoli Enterprise, TME 10, Workload Partitions Manager and X-Architecture are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol (® or ™), these symbols indicate U.S. registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml The Power Architecture and Power.org wordmarks and the Power and Power.org logos and related marks are trademarks and service marks licensed by Power.org. UNIX is a registered trademark of The Open Group in the United States, other countries or both. Linux is a registered trademark of Linus Torvalds in the United States, other countries or both. Microsoft, Windows and the Windows logo are registered trademarks of Microsoft Corporation in the United States, other countries or both. Intel, Itanium, Pentium are registered trademarks and Xeon is a trademark of Intel Corporation or its subsidiaries in the United States, other countries or both. AMD Opteron is a trademark of Advanced Micro Devices, Inc. Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries or both. TPC-C and TPC-H are trademarks of the Transaction Performance Processing Council (TPPC). SPECint, SPECfp, SPECjbb, SPECweb, SPECjAppServer, SPEC OMP, SPECviewperf, SPECapc, SPEChpc, SPECjvm, SPECmail, SPECimap and SPECsfs are trademarks of the Standard Performance Evaluation Corp (SPEC). NetBench is a registered trademark of Ziff Davis Media in the United States, other countries or both. AltiVec is a trademark of Freescale Semiconductor, Inc. Cell Broadband Engine is a trademark of Sony Computer Entertainment Inc. InfiniBand, InfiniBand Trade Association and the InfiniBand design marks are trademarks and/or service marks of the InfiniBand Trade Association. Other company, product and service names may be trademarks or service marks of others. Revised April 24, 2008 61 Racking Your Power System … Without Aspirin © 2009 IBM Corporation STG Technical Conferences 2009 Trademarks The following are trademarks of the International Business Machines Corporation in the United States, other countries, or both. Not all common law marks used by IBM are listed on this page. Failure of a mark to appear does not mean that IBM does not use the mark nor does it mean that the product is not actively marketed or is not significant within its relevant market. Those trademarks followed by ® are registered trademarks of IBM in the United States; all others are trademarks or common law marks of IBM in the United States. For a complete list of IBM Trademarks, see www.ibm.com/legal/copytrade.shtml: *, AS/400®, e business(logo)®, DBE, ESCO, eServer, FICON, IBM®, IBM (logo)®, iSeries®, MVS, OS/390®, pSeries®, RS/6000®, S/30, VM/ESA®, VSE/ESA, WebSphere®, xSeries®, z/OS®, zSeries®, z/VM®, System i, System i5, System p, System p5, System x, System z, System z9®, BladeCenter® The following are trademarks or registered trademarks of other companies. Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries. Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. UNIX is a registered trademark of The Open Group in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office. IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency, which is now part of the Office of Government Commerce. * All other products may be trademarks or registered trademarks of their respective companies. Notes: Performance is in Internal Throughput Rate (ITR) ratio based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput improvements equivalent to the performance ratios stated here. IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply. All customer examples cited or described in this presentation are presented as illustrations of the manner in which some customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics will vary depending on individual customer configurations and conditions. This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the information may be subject to change without notice. Consult your local IBM business contact for information on the product or services available in your area. All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. Information about non-IBM products is obtained from the manufacturers of those products or their published announcements. IBM has not tested those products and cannot confirm the performance, compatibility, or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. Prices subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography. 62 Racking Your Power System … Without Aspirin © 2009 IBM Corporation 31