Project Profile
                                                        UCL Academy, Adelaid Road, Camden

Consultant
■   BAM



Client
■   BAM M&E
                                     Front Entrance



Sector
■ Education



Products
■ Dinak Flue System
                                     Aerial View of site


Equipment                             Camden gets all fired up….

■ Clyde Modulex 290 & 900             Airtherm Engineering Limited have designed, supplied and installed a 500mm
                                      diameter stainless steel, twin wall, fully welded, 4 hour fire rated, gas and water
                                      tight Dinak DWhp flue system serving three high efficiency Clyde condensing
                                      boilers, with a total 2.2MW output load.

Application                           Airtherm Engineering Limited liaised with both the consultant and the contractor at
                                      all times, attending site meetings, providing comprehensive technical submission,
                                      including calculations and drawings for approval prior to manufacture of the
■ High Efficiency Condensing          equipment.

                                      The system installed comprised of a 12m horizontal run and a 26m vertical, complete
                                      with draft stabilisers and the necessary drains incorporated to allow any unwanted
                                      condense to evacuate to the system.

                                      The flue system was installed back in April 2012, however the design and liaising
                                      with the contractor begin some months earlier. Working closely with BAM
                                      Construction the installation was certainly a success.

              Clyde Modulex Boiler


          0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
Product Solution

                            •   Boilers:             Clyde

                            •   Model:               Modulex 1 x 290kw & 2 x 900kw

                            •   Application:         Chimney / Flue system

                            •   Operating mode:      Dry / Wet

                            •   Pressure:            Negative / positive pressure

                            •   Working pressure: 200 Pa (product will operate 1000pa max)

                            •   Inner wall:          316L1.4404/1.457 thickness ≤ Ø250 0,4 mm, ≥ Ø300 0,5 mm

                            •   Outer wall:          AISI 304/ 1.4301 thickness 0,5 / 0,6 mm

                            •   Insulation:          25mm thick Rockwool insulation

                            •   Sealant :            tri-lip 'o' type silicone ring
Airtherm Masterflue         •   Fuel type:           Gas/Oil/Coal/Wood




                            •   Other Application Dinak Flues can be used:
                            •   Condensing boilers

                            •   Atmospheric gas-fired boilers

                            •   Gas blown boilers
MasterFlue
                            •   Industrial ovens, large-scale establishments

 Contact Details:           •   Wood-fired stoves
 Airtherm Engineering Ltd
 Ventilation House
 Pedmore
 Stoubridge
 West Midlands
 DY9 0DS


 Tel: 0844 8092509
 Fax: 01562 887312




              0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk

Mais conteúdo relacionado

Destaque (6)

048.haikai criogenia e sub zero
048.haikai  criogenia e sub zero048.haikai  criogenia e sub zero
048.haikai criogenia e sub zero
 
Un dia ibia un oma ca as deia aloi i an al bosc tania una caseta i tania un a...
Un dia ibia un oma ca as deia aloi i an al bosc tania una caseta i tania un a...Un dia ibia un oma ca as deia aloi i an al bosc tania una caseta i tania un a...
Un dia ibia un oma ca as deia aloi i an al bosc tania una caseta i tania un a...
 
Chicago siding replacement
Chicago siding replacementChicago siding replacement
Chicago siding replacement
 
Coach Fee
Coach Fee Coach Fee
Coach Fee
 
Universidad de cordoba herazooooooo
Universidad de cordoba  herazoooooooUniversidad de cordoba  herazooooooo
Universidad de cordoba herazooooooo
 
New Methods of Trace Metals in water
New Methods of Trace Metals in waterNew Methods of Trace Metals in water
New Methods of Trace Metals in water
 

Mais de Airtherm Engineering Limited

Mais de Airtherm Engineering Limited (6)

Airtherm heat recovery solutions
Airtherm heat recovery solutionsAirtherm heat recovery solutions
Airtherm heat recovery solutions
 
Chimney & Flue Systems
Chimney & Flue SystemsChimney & Flue Systems
Chimney & Flue Systems
 
Chimney & Flues Brochure
Chimney & Flues BrochureChimney & Flues Brochure
Chimney & Flues Brochure
 
Smoke control solutions
Smoke control solutionsSmoke control solutions
Smoke control solutions
 
Airtherm grilles & louvre booklet
Airtherm grilles & louvre bookletAirtherm grilles & louvre booklet
Airtherm grilles & louvre booklet
 
Smoke control solutions
Smoke control solutionsSmoke control solutions
Smoke control solutions
 

Case Study for Flue Sstem at Camden Academy

  • 1. Project Profile UCL Academy, Adelaid Road, Camden Consultant ■ BAM Client ■ BAM M&E Front Entrance Sector ■ Education Products ■ Dinak Flue System Aerial View of site Equipment Camden gets all fired up…. ■ Clyde Modulex 290 & 900 Airtherm Engineering Limited have designed, supplied and installed a 500mm diameter stainless steel, twin wall, fully welded, 4 hour fire rated, gas and water tight Dinak DWhp flue system serving three high efficiency Clyde condensing boilers, with a total 2.2MW output load. Application Airtherm Engineering Limited liaised with both the consultant and the contractor at all times, attending site meetings, providing comprehensive technical submission, including calculations and drawings for approval prior to manufacture of the ■ High Efficiency Condensing equipment. The system installed comprised of a 12m horizontal run and a 26m vertical, complete with draft stabilisers and the necessary drains incorporated to allow any unwanted condense to evacuate to the system. The flue system was installed back in April 2012, however the design and liaising with the contractor begin some months earlier. Working closely with BAM Construction the installation was certainly a success. Clyde Modulex Boiler 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
  • 2. Product Solution • Boilers: Clyde • Model: Modulex 1 x 290kw & 2 x 900kw • Application: Chimney / Flue system • Operating mode: Dry / Wet • Pressure: Negative / positive pressure • Working pressure: 200 Pa (product will operate 1000pa max) • Inner wall: 316L1.4404/1.457 thickness ≤ Ø250 0,4 mm, ≥ Ø300 0,5 mm • Outer wall: AISI 304/ 1.4301 thickness 0,5 / 0,6 mm • Insulation: 25mm thick Rockwool insulation • Sealant : tri-lip 'o' type silicone ring Airtherm Masterflue • Fuel type: Gas/Oil/Coal/Wood • Other Application Dinak Flues can be used: • Condensing boilers • Atmospheric gas-fired boilers • Gas blown boilers MasterFlue • Industrial ovens, large-scale establishments Contact Details: • Wood-fired stoves Airtherm Engineering Ltd Ventilation House Pedmore Stoubridge West Midlands DY9 0DS Tel: 0844 8092509 Fax: 01562 887312 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk