Call Girls Miyapur 7001305949 all area service COD available Any Time
Human cremation-cremator-phoenix-1-datasheet
1. Addfield Environmental Systems Limited
Hollies Park | Cannock | Staffordshire | WS11 1DB
www.addfield.co.uk | sales@addfield.co.uk | 01543 571280
‘The most
thermally efficient,
robust and reliable
human cremators
on the market
Simply Built Better!’
Control System
PHOENIX 1
Hot Hearth
PHOENIX 1 Human Cremator
Suitable for 1500-2000 cremations a year
CFD Modelling
The PHOENIX 1 is our mid-range human cremation unit. It benefits from 115mm refractory wall thickness and
temperature controlled burners that ensure it has the lowest fuel consumption possible. Complete with a curved
hot hearth design that contains and destroys high moisture content material. A touch screen control interface is
employed with a fully automatic control sequence that removes the possibility of human error. It utilises a front
loading door design for ease use and a separate remains removal door, located on the side of the unit. The main
chamber has a volume of 2.475m³ and a maximum weight capacity of 453kg.
Allinformationshouldbeusedasaguideonly,specificationsaresubjecttochangewithoutnotice.
2. PHOENIX 1 Human Cremator
Suitable for 1500-2000 cremations a year
Robust, Reliable...
...and Efficient
Fuel Options:
† Based on general municipal waste streams
* Depending on the type waste stream being loaded and
excludes heat up time.
We reserve the right to change the specification, dimensions
and quality of materials from time to time, so long as the
alteration is minor or an improvement to the said products.
†
Addfield Environmental Systems Limited
Hollies Park | Cannock | Staffordshire | WS11 1DB
www.addfield.co.uk | sales@addfield.co.uk | 01543 571280
External Length (mm)
External Width (mm)
-Including Control Panel (mm)
External Height (mm)
-Including Door Cap (mm)
Minumum Stack Height (mm)
Stack Diameter OD (mm)
Maximum Body Weight (kg)
Weight (Approx. Tonnes)
CE Certified
EU Regulations Compliant
Max Load Capacity (kg)
Nominal Burn Rate* (kg/hr)
Thermal Capacity (kw/hr)
Power Supply 50/60hz
Diesel
LPG
N-Gas
3900
1800
2100
2400
2600
5400
600
453
14.5
YES
YES
453
50-75
190
210/230v
No
Yes
Yes
The human cremation range is designed as a two
stage cremation unit comprising of a primary loading
chamber that incorporates a hot hearth construction
for the total destruction of the solid/liquid wastes.
The unit is further complemented by an integral after
burner system; this afterburner draws the hot gases
from the primary chamber under the hearth through
an integral refractory brick system. This ensures
maximum gas turbulence/mixing is achieved thus
aiding clean combusted gases. All gases then reside
inside the after burner chamber for a minimum of 2
seconds at temperatures of 850-1150°C ensuring
complete high temperature termination/oxidation of
the gas combustion products.
The Addfield range of human cremators are CE
Certified to BS EN 746-2 :1997 and are compliant
with all emission regulations.
Machine Specifications: PHOENIX 1
Primary Chamber Sizes:
Internal Length (mm)
Internal Width (mm)
Internal Height (mm)
Chamber Volume (m³)
Front Opening Door Size:
Width (mm)
Height (mm)
Number Of Buners
2500
1100
900
2.475
1100
800
3
Allinformationshouldbeusedasaguideonly,specificationsaresubjecttochangewithoutnotice.
Machine Specifications: PHOENIX 1
3. Addfield Environmental Systems Limited
Hollies Park | Cannock | Staffordshire | WS11 1DB
www.addfield.co.uk | sales@addfield.co.uk | 01543 571280
Secondary Chamber
• Fully insulated internal refractory lining,
constructed from high grade low thermal
mass insulation.
• One secondary chamber burnout burner,
temperature controlled on-off, complete with
internal air fans.
• Integrated combustion burner air fans.
• One temperature control sensor reaches the
necessary 850°C minimum.
• 76mm refractory lined stack that reduces heat
penetration under every condition, preventing
the possibility of fire.
Primary Chamber
• Fully insulated internal refractory lining,
constructed from high grade refractory brick
ensuring a self-supporting interlocked
arrangement, hot hearth design.
• One hydraulic front loading door, push button
operated.
• One hot hearth combustion burner, temperature
controlled on-off, complete with internal air fans.
• One waste ignition burner, temperature.
controlled on-off, complete with internal air fans
• One temperature control sensor.
General Construction
• Pre-fabricated from robust mild steel box tubing, with a thickness of 3.5mm externally and 2.7mm
internally. Suitably stiffened and braced where necessary so as to be self-supporting throughout.
• Paint finishing - The steel structures are completely painted using a high grade paint system. The
standard colour of the series is grey for the stack, primary and secondary chambers. The front loading
door comes in black.
• The Primary and secondary chamber are lined with thickness of 115mm, refractory insulation that is rated
at 1600°C.
• All combustion fuel pipe work and electrical systems are weather proof and in accordance with BS7671-17.
• 1 x Touch screen controller.
Allinformationshouldbeusedasaguideonly,specificationsaresubjecttochangewithoutnotice.
PHOENIX 1 Human Cremator
Suitable for 1500-2000 cremations a year
Accessories for the human cremation range include:
• Hydraulic Lift Tables
• Recorders
• Autoloaders
• Coolers
• Storm Collars
Accessories And Consumables Brochure:
Machine Requirements
• Outside air inlet louvers in the room located at or below burner height, capable of passing 2500CFM of air.
• 1.2m clearance between the roof and the top of the machine.
ASK FOR YOUR COPY
OR DOWNLOAD AT:
www.addfield.co.uk
4. Addfield Environmental Systems Limited
Hollies Park | Cannock | Staffordshire | WS11 1DB
www.addfield.co.uk | sales@addfield.co.uk | 01543 571280
Why Addfield?
Touch Screen
Intelligent Controller
Combustion System
The burner system comprises of three fully
automatic burners, these burners come complete
with the following features:
• Flame failure controls
• Solenoid valves
• Integral continuous air fan
• Flame verification sensors
Waste Loading and De-Ashing
The human cremation series are designed for
front loading only through the main access door.
The hydraulic door is push button operated, this
feature enables the operator to open the door to
the desired height from the control panel, an
important safety feature for busy installations.
It provides better fuel efficiency and longer
refractory life.
At the end of every incineration process it is
recommended the ash should be removed
prior to the next incineration cycle. A separate
remains removal door is located on the side of the
unit. A stainless steel cooling pan is located on
the outside of the unit to prevent fluid
contamination.
Key Features:
• Data logging of deceased.
• Internet connectivity ideal for remote troubleshooting.
• Incoming and outgoing cable terminations.
• Burner control gear.
• Interface relays and contactors.
• Temperature indication and control of the
primary chamber.
• Temperature indication and control of the
secondary chamber.
• Plant status indicators.
• Cycle status indicators.
• Fault status indicators.
• Touch screen operator interface.
PHOENIX 1 Human Cremator
Suitable for 1500-2000 cremations a year
Allinformationshouldbeusedasaguideonly,specificationsaresubjecttochangewithoutnotice.
Weare
BioSecure
onallsites
Supplier to
APPCC
members
25years of
quality
incineration
FlameVent
System
Supply
& Service
globally
12months
unlimited
usage
warranty
5. MP-100 INCINERATOR
GENERAL ARRANGEMENT OF
PHOENIX 1 CREMATOR
PHOENIX 1
RLC
Addfield Environmental Systems Ltd
Unit 17 Hollies Park Cannock
Staffordshire WS11 1DP
www.addfield.co.uk
drawn:-
scale:- Not to scale
title
drg. no. rev.
date:-
daterev. description
PHOENIX 1 Cremator
Incinerate - Cremate
All information should be used as a guide only, specifications are subject to change without notice.
150mm concrete base
FLOOR PLAN
5960
3300
Observation hole
Autoloading door
Door cap
Control panel
Access panel
2641 1829
2083
3962
2210
FRONT ELEVATION
SIDE ELEVATION
REAR ELEVATION
Clean-out door
Remains tray