14. Ei keksitä polkupyörää
Suomessa
Towards nZEB:
• Roadmap of some
countries towards
nearly zero energy
buildings to improve
energy performance
of new buildings
• Many countries have
prepared long term
roadmaps with
detailed targets
• Helps industry to
prepare/commit to
the targets
Federation of European Heating, Ventilation and Air-conditioning Associations
15. REHVA benchmarking study: incentives
DE IT FR Hu BE SE
Summary
Table of Incentives
YEAR 2009 2009 2009 2009 2009 2009
Direct Funding of Energy
Yes Yes Yes Yes Yes Stopped
Repairs
FINANCIAL
Financial Help for Low-Income
Yes Yes Yes No Yes No
Households
Green Loans / Soft Loans Yes Yes Yes Yes Yes No
Third Party Financing Yes Yes Yes Yes Yes No
Stopped
Tax Deduction Yes Yes No Yes Yes
TAXES
(2009)
Labour
Lower VAT on Labour and
Stopping Materials & No Labour n.a.
Materials Material
TECHNOLOG
Subsidies on Sustainable
Y SPECIFIC
Yes Yes Yes Yes Yes Yes
Energy Devices
n.a.
per kWh (€/kWh) Yes Yes Yes Yes No
Feed-in Tariffs
n.a.
Green Certificates No Yes Yes Yes Yes
OTHERS
Rent Indexation
n.a. n.a. n.a. No n.a. No
(Owner-Renter Balance)1
1 Federation of European Heating, Ventilation and Air-conditioning Associations
At this moment, the sole case of rent indexation has been found in the Netherlands.
22. Direktiivin määritelmä
EPBD recast – Nearly zero energy
buildings nZEB
• In the directive ‘nearly zero-energy building’ means a building that has
a very high energy performance. The nearly zero or very low amount
of energy required should be covered to a very significant extent by
energy from renewable sources, including energy from renewable
sources produced on-site or nearby.
nZEB = very high energy performance + on-site renewables
• Definition of “a very high energy performance“ and “significant extent
of renewables” let for Member States
Federation of European Heating, Ventilation and Air-conditioning Associations
23. REHVA nZEB definition
ZEB has exact performance
net zero energy building (ZEB)
level of 0 kWh/(m2 a) primary
energy use of 0 kWh/(m2 a) primary energy
energy use
NOTE 1 A nZEB is typically a grid connected building with very high energy performance. nZEB balances its primary
energy use so that the primary energy feed-in to the grid or other energy network equals to the primary energy
delivered to nZEB from energy networks. Annual balance of 0 kWh/(m 2 a) primary energy use typically leads to the
situation where significant amount of the on-site energy generation will be exchanged with the grid. Therefore a nZEB
produces energy when conditions are suitable, and uses delivered energy during rest of the time.
nearly net zero energy building (nZEB)
technically reasonable achievable national energy use of > 0 kWh/(m2 a)
primary energy achieved with best practice energy efficiency measures and
renewable energy technologies which may or may not be cost optimal
NOTE 1 The Commission shall establish by 30 June 2011 a comparative methodology framework for calculation of
cost-optimal levels (EPBD recast).
NOTE 2. Not all renewable energy technologies needed for nearly zero energy building have to be cost-effective, if
appropriate financial incentives are not available.
nZEB depends on national
conditions
Federation of European Heating, Ventilation and Air-conditioning Associations
24. REHVA TF nZEB – system boundary
DELIVERED ENERGY
E Edel,i Eexp,i fi
EXPORTED ENERGY i
System boundary for nearly net zero energy building definition, connecting a
building to energy networks. Net delivered energy is delivered Edel,i minus
exported energy Eexp,i accounted separately for each energy carrier i. Primary
energy E is calculated with primary energy factors fi (simplified equation with
the same factors for delivered and exported energy carriers)
Federation of European Heating, Ventilation and Air-conditioning Associations
25. Primary energy: total or non-renewable?
Many countries have adopted in their regulations PRIMARY ENERGY and
NON-RENEWABLE primary energy factors (e.g. 1.1 for oil and 0.5 for wood)
EPBD recast defines primary energy as: ”energy from renewable and non-
renewable sources which has not undergone any conversion or
transformation process”
TOTAL primary energy and TOTAL primary energy factors shall be used
according to EPBD (meaning that there is no difference between bio or fossil
fuel and the factor always exceeds unity)
Another detail are primary energy factors for delivered and exported energy
carriers, which may or may not be equal, depending on national definition, i.e.
both equations can be used:
E Edel,i Eexp,i fi or E Edel,i f del,i Eexp,i f exp,i
i i i
Federation of European Heating, Ventilation and Air-conditioning Associations
26. REHVA nZEB system boundary
System boundary of net delivered energy
System boundary of delivered energy
Solar and internal On site renewable
heat gains/loads energy w/o fuels
NET ENERGY DELIVERED
NEED ENERGY
ENERGY NEED
BUILDING electricity
Heating heating energy
(electricity, district heat, district cooling, fuels)
Cooling TECHNICAL
cooling energy SYSTEMS district heat
Ventilation
Net delivered energy
DHW district cooling
electricity for lighting Energy use and
Lighting
Appliances electricity for production fuels
appliances (renewable and
System losses non-renewable)
Heat exchange and conversions
through the
EXPORTED
building envelope
ENERGY
electricity
heating energy
cooling energy
Energy boundary of net delivered energy. The box of “Energy need” refers to rooms
in a building and both system boundary lines may be interpreted as the building site
boundary.
Federation of European Heating, Ventilation and Air-conditioning Associations
29. Energiatodistus: How to integrate nZEB
into energy certificate scale?
nZEB as technically reasonable achievable
cost optimal for new buildings, category B or C
req. for new buildings (typically not cost optimal yet)
Revision of certificates scales needed:
• Cost optimal requirements for new buildings
cannot be any more in D category, as calculated
for 30 years period with 3% interest rate
• Existing A may be split (A+, A++) or changed
Federation of European Heating, Ventilation and Air-conditioning Associations
32. Energiatodistus: virallisesti laskettu ja todellinen
energiatehokkuus
2-kerroksinen kompakti pientalo 145 m2 D5:n ja
energiatodistuksen asetuksen mukaisesti laskettuna
Laskentatapaus ET-luku, Ostoenergia, CO2-päästöt,
U-arvo, LTO
2
ulkoseinät hyötysuhde kWh/br.m ,a ET-luokka - kWh/br.m2,a kgCO2/br.m2,a
Perustapaus suoralla sähkölämmityksellä 0.24 60 181 C 176 70
Perustapaus maalämpöpumpulla 0.24 60 187 C 106 42
Sähkölämm., parannettu n50, LTO ja U-arvot 0.19 80 146 A 140 56
Maalämpö, parannettu n50, LTO ja U-arvot 0.19 80 153 B 89 36
Nykyinen virallinen energiatehokkuustarkastelu johtaa
päästöjen kasvuun kun lämmitystapaa ja primäärienergian
käyttöä ei oteta huomioon
15.12.2011 Jarek Kurnitski
(TKK, LVI-tekniikka – 2008)
51. Example – nZEB Office building
• an office building in Paris
• a gas boiler for heating with seasonal efficiency of 90%
• free cooling from boreholes (about 1/3 of the need) is used and the
rest is covered with mechanical cooling
• for borehole cooling, seasonal energy efficiency ratio of 10 is used
and for mechanical cooling 3.5
• Ventilation system with specific fan power of 1.2 kW/(m3/s) will use
5.6 kWh/(m2 a) fan energy.
• a solar PV system providing 15.0 kWh/(m2 a), from which 6.0 is
utilized in the building and 9.0 is exported to the grid.
Federation of European Heating, Ventilation and Air-conditioning Associations
53. Example – nZEB Office building
System boundary of net delivered energy
System boundary of delivered energy
Solar and internal 15.0 PV electricity,
from which 6.0 used
heat gains/loads in the building and
9.0 exported
NET ENERGY NEED (47.2 kWh/(m2 a)) NET ENERGY NEED
Appliances BUILDING TECHNICAL
(47.2 kWh/(m2 a))
(users') SYSTEMS
10,8 Lighting
Boiler DELIVERED ENERGY
3.8 heating 3.8/0.9 = 4.2
Space Fuel 4.2
21,5 heating Free cooling
1,1
Heating of 11.9 cooling
0,6 4.0/10 = 0.4
3,2
air in AHU Compressor cooling
Cooling in 21.5 appliances Electricity 33.8
Net delivered energy
room units
7.9/3.5 = 2.3
Cooling of 10.0 lighting Ventilation 5.6
10
air in AHU
Appliances 21.5
Heat exchange Lighting 10.0
through the
(Sum of electricity 39.8)
building envelope
EXPORTED ENERGY
Electricity 9.0
Primary energy:
4.2*1.0 + (33.8-9.0)*2.5 = 66 kWh/(m2 a)
• Electricity use of cooling, ventilation, lighting and appliances is 39.8 kWh/(m2 a)
• Solar electricity of 15.0 kWh/(m2 a) reduces the net delivered electricity to 24.8 kWh/(m2 a)
• Net delivered fuel energy (caloric value of delivered natural gas) is 4.2 kWh/(m2 a) and primary
energy is 66 kWh/(m2 a)
Federation of European Heating, Ventilation and Air-conditioning Associations