2. Forma System by Formatk
Forma is an innovative
device developed to
respond to a large
range of medicalaesthetic demands.
An integral treatments’
station that offers a
concrete and dynamic
solutions in aesthetics
3. All in one system
IPL: Body and Face IPL applicators for
Hair Removal, Skin Rejuvenation,
Pigmentation, Acne and Nail Fungus
treatment.
S.T applicator: Special Skin Tightening,
using Pulsed Bipolar Radio Frequency with
double cooled electrodes to treat deep
wrinkles and stretch marks.
4. All in one system
R-Sonic applicator: using a unique
combination of bipolar continuous RF and
ultrasonic massage, to increase reticular
dermis matrix tone, improving skin’s
appearance and texture, mild wrinkles
treatment and to stimulate blood perfusion
and transepidermal active ingredients
delivery.
PLG, Peeling applicator: To peel and
smooth the skin. Special diamond-coated
disks with various surface roughness for the
different body areas, to remove the non-vital
skin layer. (Corneum Lysis)
7. All in one system
Hair removal Face and Body treatments
F/B HR 590 nm wavelength for photo types I-IV
Effective on fair facial hair and red hair
F/B*HR 650 nm wavelength for photo types I-VI
General pigmentation treatments
F/B-SR
Sun spots treatments
530 nm
Vascular lesions
Onychomycosis
9. All in one system
ST
,25 MHz Deep
2,00 MHz Shallow
PLG
Deep wrinkles treatment
Flaccid skin treatment
Striae treatment
Skin peeling
Skin polishing
Skin brightening
10. Intense Pulse Light and Thermal Relaxation Time
*Represents the time taken for heated tissue to lose 50% of
its heat through diffusion.
If the light energy persists longer than TRT of the target,
heat is conduced to the surrounding tissue leading to
unwanted thermal injury. (Katsambas & Lotti, 2003).
11. TRT in pigmented and vascular lesions
Data & histological assessment of vessel injury strongly suggest that pulse
durations for ideal light treatment are in the 1 – 10ms region and depend
on vessel diameter (Diedrickx, 1995).
Correct wavelength combine with correct TRT will achieve quick
coagulation of targeted chromophore (melanin/hemoglobin). If TRT is
exceeded, same clinical consistence is not achieved and more treatments
sessions are necessary.
pulse duration choice is as important as that of the
wavelength. (X.Muller, Lasers for Ischemic Heart Disease,2000)
12. TRT in Onychomycosis treatments
An innovative method based on delivering a beam of
radiation to a target chromophore area, to deactivate an
unwanted organism. The beam of radiation can have a
wavelength between 400nm ~ 1100nm, fluency range
~20Joule cm² and pulse width < 10ms (C. Demetrieu &
J.C. Hsia, U.S Patent application publication
2006/0212098, Sep. 21, 2006)
13. B/F HR – Hair removal
• Body and face hair removal.
• 3 modes of work: single pulse,
double
pulse
or
continuous
pulses.
Technical information:
Energy: up to 20 j/cm2.
Wavelength: 590/650 nm
Spot size: body3cm², face 1.6cm²
Pulse duration:
• Single: from 3 to 10 milliseconds
• Double: from 2 to 5 milliseconds.
• Continuous: from 1.1 to 3.3 milliseconds
17. B/F SR –Skin rejuvenation
Body and face Skin Rejuvenation and
Fungus Treatment
3 modes of work: single pulse, double
pulse, or continuous pulses (single
pulse every 0.33 seconds).
Technical information:
Energy: up to 22 j/cm.
Wavelength: 530 nm
Spot size: body 3 cm², face 1.6 cm²
Pulse duration:
Single: from 3 to 10 milliseconds
Double: from 2 to 5 milliseconds
Continuous: from 1.1 to 3.3 milliseconds
25. F–AC Acne treatment
Face acne treatment
Technical information:
Energy: up to 22 j/cm.
Wavelength: 440 nm
Spot size: 1.6 cm2
Pulse duration:
• Single: from 2 to 6 milliseconds
• Double: from 1.5 to 3 milliseconds
• Continuous: from 1.1 to 2.4
milliseconds
30. HISTORY
During his studies on high-frequency
currents, D'Arsonval discovered that an
electric current at a frequency of 10 KHz or more
produced a sensation of heat in crossing the
living tissues, without being accompanied by
painful muscle contractions that you feel
more low frequencies. It was 1892, the
year that marks the entrance of
electromagnetism in Medicine.
31. DIATHERMY
The term diathermy (dia = through, therme
= heat) was coined in 1907 by
Nagelshmidt to indicate the heating of
living tissue produce by the conversion of
high frequency currents in heat.
33. Thermal energy transfer
The electromagnetic heating has some
advantages over other forms of heating
(conduction, infrared radiation). In particular,
even with the long waves, depths of
treatment are significantly higher.
34. While in the heat by the temperature within the
tissue decays exponentially to the physiological
value (37 ° C) in a few millimeters,
electromagnetic heating allows for a smoother
temperature distribution can also be of interest
to depths of several centimeters that can not be
reached with other external means.
41. ST Skin Tightening
Bi polar pulsed RF, producing collagen
renewal, for deep wrinkles and stretch
marks treatments.
Dual-task feature to choose between two
modes of pulse:
Deep: deep penetration, for fleshy areas
such as cheeks (1.25 MHz)
Shallow: shallow penetration, for bony
areas such as eyebrow and forehead
(2MHz)