Handwritten Text Recognition for manuscripts and early printed texts
Estap 2012-2013 catalogue all pages
1.
2. ESTAP HEAD OFFICE - SANCAKTEPE / İSTANBUL
ESTAP FACTORY - ESKİŞEHİR
40.000 m2 open area, 20.000 m2 closed area. Making production with 400 employess.
4. ServerMAX free standing
• Compatible with all EIA-310
compliant 19” equipment. All
type of servers, brands will
physically fit in ServerMAX
server cabinet.
• Bottom plate has an extra
perforated plate to prevent
insects or mice from reaching
the cables.
• Efficient passive air circulation
• Numbered U positions facilitate
easy installation of rack mounted
equipment.
3
5. ServerMAX free standing
600x1000 - 800x1000
ServerMAX free standing enclosure
26U 36U
42U
47U
42U
47U
600 x 1000*
800 x 1000*
ServerMAX protects your
technological investments
• 19”
• HIGH QUALITY PRODUCTS
• COMPLIMENTS YOUR DECOR AND
ENVIRONMENT
• SECURE AND STURDY
• EASY TO MAINTAIN: LARGE INNER
VOLUME
• HIGH SECURITY FOR UNAUTHORIZED
ACCESS
• STRONG PROTECTION AGAINST
PHYSICAL DAMAGE
• EXCELLENT PASSIVE AIR VENTILATION
* Please check drawing pages for cabinet sizes.
4
6. SERVERMAX FREE STANDING ENCLOSURES FOR
STANDARD DIMENSIONS:
Heights: 26U, 36U, 42U, 47U
Width: 600 mm
Depth: 1000 mm
Heights: 42U, 47U
Width: 780 mm
Depth: 1000 mm
LOAD CARRYING CAPACITY: 1000 kg
600x1000 -800x1000
COLOUR:
RAL 9005 black
RAL 7035 light grey
STANDARDS:
ISO 9001 : 2008 Quality Management Systems
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for
electronic equipment)
Overall cabinet dimensions for IEC 297-2
KEY FEATURES
Adjustable mounting depth: 19” mounting angles
are adjustable in depth for various mounts for adjustable
depth distance, please look at drawing pages.
Bottom plate: fitted with an additional plate to
prevent insects/vermin. If necessary a filter may be
integrated to prevent dust infiltration.
Bottom plate is complete with pre-punched removable
sections: when airflow comes from the floor, these
sections can be removed to provide efficient airflow
inside the cabinet.
Reversible doors: Front and rear doors may be
detached and reversed to allow the door to open from
the rear of the cabinet.
Side doors are split in two: Front section used to
access the cabinet; additional smaller section secured
inside the cabinet. If additional ventilation is necessary it
can be demanded as vented. The main inner strip of this
panel is designed for the housing of cables and power
strips.
Numbered “U” positions facilitate easy installation
for rack mounted equipment.
Vertical mounting rails with square holes;
adjustable in depth.
5
7. ServerMAX free standing
600x1000 - 800x1000
Optional plexi front door: May be used instead of
vented front door.
All in one: ServerMAX includes; casters, doors, ground
studs, levelling feet, roof, bottom, side panels, C-rails, tilt bars,
unloaded fan tray.
Optimized depth: 1000 mm.Today and next generation
installation of servers, for power distribution and cable
management. 1000 mm is the optimum depth for comfort
cabling, housing server and gaining space in data centers.
Fixing to floor: ServerMAX can be easily fixed to the
floor when necessary. A floor fixing kit is used for this
purpose. Please see accessories for floor fixing kit.
Efficient passive ventilation: New generation servers
and networking products need adequate ventilation to
operate efficiently. ServerMAX server cabinets provide
6
efficient passive ventilation because of its vented structure of
front and rear doors. Front and rear doors have maximum
perforation (%63) patterns for high-density cooling that meets
or exceeds server manufacturer’s ventilation requirements.
There is a fan tray on roof: Removable easily from
the top.When the maintanence of fans are required, it can be
reached directly from the top without touching any mounted
device or servers.
It is possible to attach a filter on top of the server fan unit.
Generous cable access holes are provided in the roof
and base. One on top, one on bottom holes are special ESTAP
style cable entries; sliding type with rubber edges.
8. FEATURES
Quick release side doors: During installation and while
conducting routine maintenance of installed equipment, it is
often advantageous to remove the side panels. Quick release
slam latches and locks on the side panels allow for quick and
easy access.
600x1000 - 800x1000
Anti-tilt bars: As standard, ServerMAX is fitted with
2 sliding type tilt bars to make the cabinet stable in weight
center. Whenever the servers are moved out, tilt bars are
drawn out to counter-balance the cabinets weight center.
Double opening rear doors improve access and
serviceability to rear of rack mounted equipment.The split
rear doors help to maximize floor space. Only 390 mm for
W=780 mm cabinets of clearance is required behind the
enclosure to allow for door swing.
D= 200 mm extention unit: If deeper equipment
is loaded into ServerMAX cabinets requiring additional
depth for cable radius, cable bundles, PDU housing etc, a
D=200mm extension unit may be installed to ServerMAX
cabinets: the rear door is removed and reinstalled onto the
extension unit. (Please see diagrams on pages 18-19)
Expansion: ServerMAX enclosures can be easily
expanded to create complete rows of enclosures without
side panels. With a proper baying kit (please see accessories)
all cabinets are bayed easily and quickly.
Welded: Bottom and roof of the cabinet is completely
welded and a closed structure. Sturdy and rugged, it protects
against physical elements like dust, insects.
Lockable doors and side panels: Front and rear
doors are lockable using a 3 point locking mechanism.
A handle-style locking system provides increased security to
prevent unauthorized access. All doors and side panels are
only accessible with a key provided by ServerMAX.
Stability: Heavy duty frame design, 2 mm mounting rails,
angles, heavy duty type castor group provide 1000 kg load
rating.
7
9. ServerMAX free standing
FEATURES
600x1000 - 800x1000
Grounding: All parts are fitted with grounding studs to
provide electrical continuity.
Surface treatment: Fosfat coating, oil remove and
passivation.
Heavy duty vertical frames: Instead of 4ea. vertical
profiles, ServerMAX cabinets are 6ea.(3ea.in left+3ea.in right)
main vertical profiles that gives extra stability for heavy loads.
Material thicknesses: Roof, bottom, vertical main frames,
1,5 mm C-rails, 19” mounting angles, profiles and all frames
are 2 mm thickness. Sturdy steel construction.
More C rails: Instead of 6ea. there are 8 horizontal C rails
in depth for extra stability. (42U, 47U)
Paint: Electrostatic powder coating.
Reinforced bottom: Bottoms are reinforced with
horizontal profiles in width and depth for extra stability.
Rounded aesthetic monoblok front door: Front
door is a heavy duty type monoblock perforated and welded
structure. It’s shape is rounded in front to enhance the
aesthetics.
Easy to dismantle and assembly: The rigidly welded
frame construction can be dismantled and assembled easily
without any special tools.Thus, narrow doors, staircases and
lifts are no problem.
Special cable entry on top and bottom case:
Bottom plate and top case have a special cable entry,
completely closed, sliding type with rubber edges.
Cables are entered and fixed.
Housing for cabling: The cabinet itself has enough
housing for vertical cable management at back. For 600x1000
cabinet, cable rings are used for cable management.
For 780x1000 cabinets there are special vertical cable
management panels of Ieft & right with cover plate for hiding
and protecting the cables. These allow customers to easily
route, manage and access large numbers of data cables even
while an enclosure is loaded with rack mount equipment and
bayed in a row.
Power/energy distribution: Rear power distribution
housing at back of the cabinet provide easy access to multiple
receptacles. Vertical power distribution strips can easily
be mounted in that space. This housing never interfere
with equipment or takes any valuable “U” space. Providing
increased accessibility to receptacles allows customers to
support more power cords within the enclosure.
Power strips are the length of cabinets: 26U, 36U, 42U, 47U.
8
10. ADDITIONAL FEATURES FOR
More Volume Width=780 mm:
Provides more efficient
cooling and more
professional cabling
ServerMAX Width=780 mm cabinet has all
features mentioned before. Plus these additional
features.
800x1000 mm
Vertical cable management panels can be used at
rear of the cabinet for professional cabling and to hide the
power cables.
Extra Housing space for cabling and power
distribution: This extra space provides housing for the
vertical cable management panels and the vertical power
strips.
Left and right front panel: Front panels can be used to
hide unwanted views of cables. If server cabinet is additionally
used for networking in the front, cable management is needed:
Estap cable rings can be used to attach this panel and secure
cables.Access holes allow the patch cord to reach the rear of
cabinet.
9
11. ServerMAX free standing
SELECTION STEPS FOR
600x1000
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure for ServerMAX W=600 mm:
Product range name
+
U height (HHU)
The product options have the below structure:
Colour option (MX)
+
Front door option (FX)
+ Rear door option (RX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example : SRV42U (Width=600 mm)
Step 2
Please choose the colour from the table and place it after the part number.
For example : SRV42U - M01 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example : SRV42U - M01 - F15 (FX= look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example : SRV42U - M01 - F15 - R07 (RX= look at the RX rear door options on the next page)
10
12. PART NUMBER DEFINITION FOR
600x1000
FX***
MAIN PART NUMBER STRUCTURE
SRV
Product
range
ServerMAX
F14**
U
height
+
SRV
Front door options
- HHU
600
HHU
26U
36U
SRV
42U
47U
H
SRV : ServerMAX product range (W=600 mm)
HHU : “U” height
WD : 600x1000 mm
Front view
F15
R07*
600
OPTIONS
MX - FX
MX
- RX
Front
door
options
Colour
options
+
FX
M01
F14**
M02
600
Rear
door
options
+
RX
R07*
F15
H
H
R07*
MX :
Colour options
M01= RAL 9005 black
M02= RAL 7035 light grey
Front view
Front view
RX***
Rear door option
FX : Front door options
F14**= Single opening, monoblock,welded, curved %63
perforated door, 3 point handled locking
F15= Single opening, monoblock,welded, curved plexi glass
door, 3 point handled locking
R07*
600
RX : Rear door option
q R07*= Double opening %63 perforated door with
complete metal frame, 3 point handled locking
H
Back view
H= Enclosure height
* R07 is the standard rear door.
** F14 is the standard front door.
*** F14, F15 R07 can be used as front or rear door.
11
13. ServerMAX free standing
TECHNICAL DRAWINGS FOR
600x1000 - 26U/36U/42U/47U
R07* / ***
F14** / ***
F15***
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
ServerMAX cabinets 19” 600 x 1000 mm
SRV26U
26U 600x1000 mm
26
600
1000
740
1179
1291
1338
SRV36U
36U 600x1000 mm
36
600
1000
740
1623
1735
1782
SRV42U
42U 600x1000 mm
42
600
1000
740
1890
2002
2049
SRV47U
47U 600x1000 mm
47
600
1000
740
2112
2224
2271
* R07 is the standard rear door.
** F14 is the standard front door.
*** F14, F15, R07 can be used as front or rear door.
12
14. TECHNICAL DRAWINGS FOR
600x1000 - 26U/36U/42U/47U
565
200
180
(Min 795)
740
H
Front view
Bottom view
Mounting profile
1000
12
600
F14**
(Min 25)
56
140
140
906
200
(Min 158)
184
600
600
F15
H
Front view
47
H
Side view
Back view
Front view
600
200
R07*
1000
200
600
30
H
Top view
H= Enclosure height
Iso view
Front view
*R07 is the standard rear door.
** F14 is the standard front door.
13
15. ServerMAX free standing
PART NUMBER DEFINITION FOR
800x1000
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure for ServerMAX W=780 mm:
Product range name
+
U height (HHU)
+ Width (WW, D=1000 mm)
The product options have the below structure:
Colour option (MX)
+
Front door option (FX)
+
Rear door option (RX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example : SRV42U8 (Width=780 mm)
Step 2
Please choose the colour from the table and place it after the part number.
For example: SRV42U8 - M01 (MX= Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: SRV42U8 - M01 - F16 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: SRV42U8 - M01 - F16 - R08 (RX= Look at the RX rear door options on the next page)
14
16. PART NUMBER DEFINITION FOR
800x1000
FX***
MAIN PART NUMBER STRUCTURE
Front door options
SRV - HHU - WW
Product
range
ServerMAX
SRV
Width
&
depth=
1000 mm
U
height
+
HHU
+
780
8
42U
SRV
F16**
WW
47U
H
SRV : ServerMAX product range
HHU : “U” height
WW : Width (W=780 mm)
OPTIONS
MX - FX
- RX
Front
door
options
Colour
options
MX
Front view
+
FX
M01
F16**
M02
F17
R08*
780
780
Rear
door
options
+
RX
F17
R08*
H
H
R08*
MX : Colour options
M01= RAL 9005 black
M02= RAL 7035 light grey
Front view
Front view
RX***
Rear door option
FX : Front door options
F16**= Single opening, monoblock, welded, curved %63
perforated door, 3 point handled locking
F17= Single opening, welded, curved plexi glass door,
3 point handled locking
R08*
780
RX : Rear door option
R08*= Double opening %63 perforated door with
complete metal frame, 3 point handled locking
H
Back view
H= Enclosure height
* R08 is the standard rear door.
** F16 is the standard front door.
*** F16, F17 R08 can be used as front or rear door.
15
17. ServerMAX free standing
TECHNICAL DRAWINGS FOR
800x1000 - 42U/47U
R08*/***
F16**/***
F17***
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
ServerMAX free standing cabinets 19” 780 x 1000 mm
SRV42U8
42U 780x1000 mm
42
780
1000
740
1890
2002
2049
SRV47U8
47U 780x1000 mm
47
780
1000
740
2112
2224
2271
* R08 is the standard rear door.
** F16 is the standard front door.
*** F16, F17, R08 can be used as front or rear door.
16
18. TECHNICAL DRAWINGS FOR
800x1000 - 42U/47U
780
745
F16**
(Min 762)
740
H
(Min 27)
44
140
140
906
200
(Min 190)
195
300
280
19”
Mounting profile
Bottom view
1000
780
12
780
Front view
H
H
Side view
47
Front view
F17
Back view
Front view
780
780
R08*
200
300
Top view
H= Enclosure height
29
1000
H
Iso view
Front view
* R08 is the standard rear door.
** F16 is the standard front door.
17
19. ServerMAX free standing
TECHNICAL DRAWINGS FOR
600x1000
Technical drawing of extention unit D=200 mm for 600x1000 mm ServerMAX
Top view after extention unit
600
70
200
145
Note: Depth of existing cabinet + 200 mm
Exploded view
Iso view
Part
number
Width:
overall
(mm)
Depth:
overall
(mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
SRV26U EXT620
26U Extention unit D=200 mm, suitable for ServerMAX W=600 mm
26
600
200
1281
1328
SRV36U EXT620
36U Extention unit D=200 mm, suitable for ServerMAX W=600 mm
36
600
200
1726
1773
SRV42U EXT620
42U Extention unit D=200 mm, suitable for ServerMAX W=600 mm
42
600
200
1993
2040
SRV47U EXT620
18
Product definition
(mm)
U
Size
ServerMAX 19” 600 x 1000 mm extention unit
47U Extention unit D=200 mm, suitable for ServerMAX W=600 mm
47
600
200
2215
2262
20. TECHNICAL DRAWINGS FOR
800x1000
Technical drawing of extention unit D=200 mm for 780x1000 mm ServerMAX
Top view after extention unit
780
70
200
145
Note: Depth of existing cabinet + 200 mm
Exploded view
Iso view
Part
number
Product definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Height:
without
levelling feet
(mm)
Height:
with casters
(mm)
ServerMAX 19” 780 x 1000 mm extention unit
SRV42U EXT820
42U Extention unit D=200 mm, suitable for ServerMAX W=780 mm
42
780
200
1993
2040
SRV47U EXT820
47U Extention unit D=200 mm, suitable for ServerMAX W=780 mm
47
780
200
2215
2262
19
21. ServerMAX free standing
TECHNICAL SPECIFICATIONS
TESTS AND CERTIFICATIONS
Environment
EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30,
IEC60917 and IEC60297
Industrial environment
EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297
Statical mechanical structure load test
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297,
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and flame resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and
IEC60297
Transportation
ETS300019-1-2 Class 2.3
Storage
ETS300019-1-1 Class 1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530, TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS
20
KEY FEATURES
Main profile (framework) has an aesthetic structure which
increases mechanical resistance, folded at an angle of 90
degrees and consisting of 4 bends for each profile. In total;
16 folds provide framework stability.Additionally, 2 piece
vertical side panel divider profile provides additional
resistance each with a 4 fold design; total of 8 fold additional
support. In total ServerMax main profile framework consists
of a 24 fold engineering design. Manufactured and tested to
provide axial (x, y, z) resistance that meets EN 61587-1 / 5.2.1
and 5.2.2, and external impact resistance that meets
EN 61587-1 / 5.3.3.
Bottom and upper cases have a structure to increase
the resistance and strength of the cabinet by monoblock
bended, welded and profile-interlocking design. Profiles are
manufactured to interlock bottom and upper cases with
screws. The bottom case providing cable access is fitted with
a sliding blanking access plate to prevent dust.
A rubber edge on the cable access plate and sliding structure,
it is possible to fix the cables and allows cables to be placed
into the cabinet without any damage.
Additional there are pre-punched knock outs for air
distribution delivered from raised floor.
Rear door in standard configuration is a double opening
door which is removable and lockable. Integral locking is a 3
point locking system.
Rear doors can be opened up to 215 degrees, are removable
and lockable with handle type locking unit.
Side panels have a structure that can be opened and
removed with slam latch and key.They are lockable and
removable. Side panels consist of a divider profile which
creates 2 pieces side panels on each side. Original functional
side panel is lockable and removable as mentioned above;
the smaller side panel is fixed from inner side with screws.
If additional ventilation is needed this panel can be replaced
with a slotted / perforated one.
Within this engineering construction, the original functional
side panel becomes easy to carry while the divider profile
provides better resistancy.
Front doors are single opening, monoblock, welded, curved,
%63 perforated in standard. Integral locking as 3 point locking
system. For options please see the related diagrams and
technical charts in pages 11-15.
Front door can be opened up to 215 degrees, removable and
lockable with handle type locking unit.
Vented top panel housing with a dedicated space for
ventilation, the fan module system allows easy installation of
max. 6 fans from top.
19”(inch) mounting angles (2ea. in front and 2ea. in rear) are
part of cabinet interior configuration and adjustable in depth.
Baying is possible for side by side applications without
side panels. Levelling feet and integrated castor group are
standard in shipping configuration.
The cabinet meets EN 61587-1, IEC 60917, IEC 60297
standards, RoHS compliancy, Gost and TSE certified.
Cabinets are manufactured in our factory which has
ISO 9001: 2008 Quality Assurance System and our
responsibility for enviroment with ISO 14001:2004
Environmental Management System.
22. TECHNICAL SPECIFICATIONS
Custom number
85380000 / 85381000 / 853710990019
Packs of (ea.)
1
Shipping structure
Assembled
Mounting surface
Stand alone
Load carrying capacity (kg)
1000
Certification on product
TSE, Gost
Surface finish
Electrostatic powder coated c/with surface treatment , 80 +/ - 5
micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11
STANDARD PRODUCT
Standart colour
RAL 7035, RAL 9005
Baying
Possible with baying kit for side by side applications without side
panels
IP protection standard
IP20
FRONT DOOR
Single opening, monoblock, welded,curved, %63 perforated
Front door construction
Monoblock curved, welded construction
Front door lock
Handle type, 3 point locking
Hinge system
Spring loaded
Door opening angle and swapping
215 degree
Door opening angle and swapping
215 degree
FRAMEWORK
Top and bottom base units
Solid Metal 2 mm
Top and bottom base units construction
Completely welded corner socket system
Uprights
Solid metal, 2 mm
Uprights construction
Tightly fixed into top and bottom base units
3 times folded 3 x 2 = 6 folds
SIDE PANEL DIVIDER PROFILE
Solid metal 2 mm
Side panel construction
Tightly fixed into top and bottom base units
4 times folded x 2 = 8 folds
INTERIOR PARTS
19’’ mounting angles
Solid metal, 2 mm
1 times folded for an L profile system
U marking available
2 ea. at rear, 2 ea. at front
Pre-configured as 19’’
Zinc plated, passivated, 8-12 micron
Adjustable in depth
Omega type support rails in depth
Solid metal, 1,5 mm
3 times folded for W=600 mm cabinets
Omega type folded for W=780 mm cabinets
3 ea. at left, 3 ea. at right 26U and 36U
4 ea. at left, 4 ea. at right 42U and 47U
SIDE PANEL
Solid metal, 1 mm. Left and right (2ea.)
Construction
Lockable, removable c/with slam latches and lock
Lock
Barrel type lock unit, single point + slam latch (2ea)
REAR DOOR
Solid metal, 1 mm
Rear door construction
Double door opening, %63 perforated, lockable, removable
Rear door lock
Handled type lock unit, 3 point
Hinge system
Spring loaded
For CUSTOMIZED PRODUCTS rather than
above options, please contact sales department.
21
23. ServerMAX free standing accessories
FREQUENTLY USED ACCESSORIES SELECTION CHART FOR SERVERMAX
Estap has a wide range of accessories: Heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable
managements, cable rings, organisers, trays, plinths and so on...
* See the other and part number definition on pages 173-213.
* Please state colour choice in your orders.
M01=RAL 9005 black and M02= RAL 7035 light grey
Frequently used accessories selection table
ServerMAX / Vertical PDU part numbers
M44 24 AL IEC AMP MCB
ServerMAX / Cable management unit
(suitable for 780x1000 Server Cabinets)
Enclosure sizes*
800x1000
42U
M44ORG42SRV
47U
M44ORG47SRV
ServerMAX /
Cable management rings
Part number
44x30
K44RING01
44x60
K44RING021U
44x110
K44RING03
70x160
K44RING04
ServerMAX /
Floor fixing kit
Enclosure sizes*
600x1000
800x1000
M44DPR03
22
* Please check drawing pages for cabinet sizes.
M44DPR04
24. Data Center solutions
’Data center solutions
which is mission critical,
require reliable, flexible
and scalable infrastructures
alongside guarantied high
performance.
ESTAP OFFERS energy efficient
MANAGABLE, MEASURABLE AND
SCALABLE SOLUTIONS TO DATA
CENTER PROJECTS.
23
25. Data Center
solutions
MAIN FEATURES
DCMax data center server cabinets are designed to provide
hot corridor, cold corridor and its containment structure,
which has been widely used in enterprise datacenters.
Design criteria serves to provide:
• Maximum performance for cooling of IP20 and IP55
solutions
• Wide range of cabinet sizes and accessories
H=42/47U – W=600/800 mm – D=1000/1100/1200 mm
• Load capacity= 1500 kg. DCMax structure is suitable for
carrying heavy loads and is seismic tested to 1000 kg
(BELLCORE GR-63-CORE ZONE 4, NEBS)
• Maximum inner space for servers
• Minimum environmental space requirement
• Professional cable management
• Heavy duty structure
• Compability with all vendors servers
• High technical performance, grounding continuity
• Power / energy management
• Controllable and reliable security with monitoring
• Aesthetic and professional design
19” OPEN FRAME CABLING CABINET, IP20
Estap System Rack cabinet series offers an ideal solution
for the data center which include high density cabling
and need effective cooling. Its heavy-duty structure
is suitable to house the component of the network
backbone.
24
HOT & COLD CORRIDOR APPLICATIONS
Estap datacenter cooling solution offers real and energy
efficient cooling with its wide product range such as
water chilled sidecoolers, in-row coolers, heat removal
units, cold corridor containment and so on.
26. Data Center solutions
LCD CONSOLES & KVM
The high quality KVM switch is ideal for use in small to middle sized server
rooms and provides direct connection to many servers.
Estap consoles with/without integrated KVM are a space saving and
functional solution for a comfortable connection to PCs, servers KVM
installations in a 1U rack-mounting area.
REMOTE MONITORING SYSTEM
Supplies real time monitoring and
management solution for data centers
to secure flawless operation with high
resilien.
POWER DISTRIBUTION UNITS (PDU)
Estap managed IP PDUs provide reliable power distribution
and monitoring of individual outlets to data centers, for both
Blade servers.
Designed for high density, mission critical server applications,
Estap IP PDU range offers an excellent solution to scale
electrical power budgets and fight against the inevitable rise of
electrical energy costs in the data center business.
25
27. Data Center
solutions
Data Center solutions
ESTAP
Data center
COOLING
SOLUTIONS
Estap data center IT cooling
solution ensures maximum
IT availability at minimum running
cost. The power usage effectiveness
in the data centers indicates
that approximately %30 of the
total incoming power is utilised
by cooling and cooling related
equipment.
FEATURES
Cold corridor
• Liquid / gas cooling
• High cooling capacity
• Easy mounting and maintenance
ESTAP DATA CENTER COOLING SOLUTIONS
Hot corridor
26
In Row coolers are utilised. To serve for cooling and/or
enhancing the cooling capacity of a cold corridor containment.
Heat rejection can be handled by an existing chilled water system:
The modular solution serve scalable cooling capacity growth.
28. Universal Line free standing
• Provides unique features for
system designers, installers and
network managers.
• Suitable for office, equipment
room and cabling closet
installations
• Exceptionally sturdy and strong
• Highly cost-effective and
assembly-friendly solutions
for numerous applications
• Multiple cable entry points
provide maximum versatility
• Delivered as assembled and side
by side mounting is possible
27
29. Universal Line free standing enclosures
600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000
Universal Line free standing enclosures
16U 20U 22U 26U 32U
26U 36U
42U
36U
39U
42U
44U
47U
600 x 600*
600 x 800*
600 x 1000*
47U
Universal Line JUMBO free standing enclosures
32U
42U
36U
39U
42U
44U
47U
800 x 1000*
47U
Universal Line PCcase
36U
600 x 800*
Highly cost-effective and
assembly-friendly solutions
for numerous applications
* Please check drawing pages for cabinet sizes.
28
800 x 600*
800 x 800*
30. UNIVERSAL LINE ENCLOSURES FOR
STANDARD DIMENSIONS:
Heights:16U, 20U, 22U, 26U 32U, 36U, 39U,
42U, 44U, 47U
Width: 600 mm
Depth: 600 mm - 780 mm
Heights: 26U, 36U, 42U, 47U
Width: 600 mm
Depth: 1000 mm
LOAD CARRYING CAPACITY: 600 kg
600x600 - 600x800 - 600x1000
COLOUR:
RAL 9005 black
RAL 7035 light grey
STANDARDS:
ISO 9001: 2008 Quality Management Sytem
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for
electronic equipment)
Overall cabinet dimensions for IEC 297-2
KEY FEATURES
• The Universal Line free standing cabinets are suitable for
office, equipment room, housing server and cabling closet
installations. Attention to style with attractive colours
black RAL 9005 and light grey RAL 7035 and smoked
glass door reinforced with vertical left and right metal
frames means that cabinets can be deployed in the most
demanding of office environments where appea counts.
• However, Universal Line are an exceptionally sturdy and
strong cabinet enabling usage for all applications.
• Front door frames are available with orange decorative
stripe.
• The Universal Line offers a highly cost-effective and
assembly-friendly solution for numerous applications in
the field of network technology and electronics. The
Universal Line is highly configurable to the end users
requirements and provides unique features to benefit
system designers, installers and network managers.
• Standard cabinet is completely assembled and delivered
as a single enclosure.
• Side by side mounting is also possible when side panels
are not used; baying kits to be added.
• The rigid welded frame construction can be
disassembled and assembled easily without any special
tools. Thus narrow doors, staircases and elevators are
no problem.
29
29
31. Universal Line free standing enclosures
Universal Line free standing enclosures
offer a wide range of options.
30
32. UNIVERSAL LINE FREE STANDING ENCLOSURES FOR
600x600 - 600x800 - 600x1000
EASY TO ACCESS
Front door
Features a full-length smoked and shatterproof glass
door with decorative accent stripe reinforced with
left/right metal frames and integral locking mechanism.
Side doors
Lockable, removable, complete with slam latches and
barrel type locks.
19” mounting angles (front/2ea and back/2ea) allow for
flexible configuration and are adjustable in depth.
C rails 3 fold 1,5 mm thickness to increase the stability
of equipment .
Levelling feet included as a standard feature.
Rear door
Lockable, removable lock.
Secure, locking front and back doors with spring loaded
hinges offer best accessibility even when connecting
the cabinets. The door hinge is easily swapped from
one side to the other to change the direction the door
opens.
Giving you 4-way access to equipment. Front and rear
door can be replaced giving you flexibility for different
installations.
CABLE ACCESS
Multiple cable entry points provide maximum versatility.
There is a rubber edge sliding cover mechanism that
protects and fix the cables. There is a brush on the rear
panel that can be positioned on top or bottom (brush
entry available on height of 26 U and above)
CONSTRUCTION
Rigid welded frame construction in steel sheet, rapidly
disassembled with 4 screws per corner. Corners of base
has welded sockets that tightly fixed into the columns
give maximum stability.
Frames are made with a 24-fold design for increased
stability.
Vented Pagoda style top cover with built-in space for
available top mount ventilation fan system providing
protection against dust flow from the top, additionally
this causes a chimney effect to provide passive air flow
via convection.
31
33. Universal Line free standing
SELECTION STEPS FOR
600x600 - 600x800
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
roduct range name
+
U height (HHU)
+
Width&Depth (WD)
+
Rear door option (RX)
The product options have the below structure:
C
olour option (MX)
+
Front door option (FX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U66
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U66 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: CKR42U66 - M02 - F01 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U66 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page)
32
34. PART NUMBER DEFINITION FOR
600x600 - 600x800
FX
MAIN PART NUMBER STRUCTURE
CKR
Product
range
Universal Line
F01*
Width
&
Depth
U
height
+
CKR
Front door options
- HHU - WD
+
HHU
F02
600
600
WD
16U
20U
22U
26U
32U
H
66
36U
CKR
H
68
39U
42U
44U
Front view
47U
Front view
F03
CKR : Universal Line free standing product range
HHU : “U” height
WD : Width and depth
F04
600
600
OPTIONS
MX
-
- RX**
Front door
options
Colour
options
MX
FX
+
FX
Rear door
options
+
H
H
RX
M01
F01*
R01
M02
F02
R02
F03
* F01 is the standard front door.
** RX - R01 is standard rear door for 22U and below, is optional door for 26U and above
R02 is standard rear door for 26U and above with 2 brushed cable access part
Front view
RX**
Rear door options
300
R02
55
MX :
Colour options
M01= RAL 9005 black
M02= RAL 7035 light grey
FX : Front door options
F01*= Single opening shatter proof glass door with left and
right metal frame slotted, single point handled locking
F02= Single opening shatter proof glass door with complete
metal frame slotted, single point handled locking
F03= Single opening solid metal door, single point handled
locking
F04= Single opening %63 perforated door with complete
metal frame slotted, single point handled locking
RX** : Rear door options
R01= Single opening solid metal rear door with barrel type
single point lock unit for 22U and below
R02= Single opening solid metal rear door with barrel type
single point lock unit with brushed cable entry, for 26U and
above
Front view
R01
600
55
F04
H= Enclosure height
300
Back view
Back view
33
35. Universal Line free standing
TECHNICAL DRAWINGS FOR
600x600 - 16U/20U/22U
R01**
F01*
F02
F03
F04
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line free standing cabinets 19” 600 x 600 mm
CKR16U66
16U 600x600
16
600
600
390
715
865
880
945
CKR20U66
20U 600x600
20
600
600
390
890
1042
1057
1122
CKR22U66
22U 600x600
22
600
600
390
980
1131
1146
1211
* F01 is the standard front door.
** R01 is the standard rear door for 22U and below.
34
36. TECHNICAL DRAWINGS FOR
600x600 - 16U/20U/22U
600
395
F01*
(Min 30)
111
300
(Min 520)
390
478
200
H
(Min 45)
95
Front view
Bottom view
600
19”
F02
Mounting profile
H
600
600
Front view
600
F03
H
Side view
Front view
H
Back view
Front view
600
600
600
F04
H
Top view
H= Enclosure height
Iso view
Front view
* F01is the standard front door.
35
37. Universal Line free standing
TECHNICAL DRAWINGS FOR
600x800 - 16U/20U/22U
R01**
F01*
F02
F03
F04
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line free standing cabinets 19” 600 x 780 mm
CKR16U68
16U 600x780
16
600
780
555
715
865
880
945
CKR20U68
20U 600x780
20
600
780
555
890
1042
1057
1122
CKR22U68
22U 600x780
22
600
780
555
980
1131
1146
1211
* F01 is the standard front door.
** R01 is the standard rear door for 22U and below.
36
38. TECHNICAL DRAWINGS FOR
600x800 - 16U/20U/22U
600
F01*
395
200
(Min 30)
130
300
658
(Min 701)
555
H
(Min 45)
91
Front view
600
F02
19”
Bottom view
Mounting profile
H
600
780
Front view
H
600
F03
H
H
Front view
Side view
Back view
Front view
600
600
780
F04
H
Top view
H= Enclosure height
Iso view
Front view
* F01is the standard front door.
37
39. Universal Line free standing
TECHNICAL DRAWINGS FOR
600x600 - 26U/32U/36U/39U/42U/44U/47U
R02**
F01*
F02
F03
F04
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line free standing cabinets 19” 600 x 600 mm
CKR26U66
26U 600x600
26
600
600
390
1160
1309
1324
1389
CKR32U66
32U 600x600
32
600
600
390
1422
1576
1591
1656
CKR36U66
36U 600x600
36
600
600
390
1603
1754
1769
1834
CKR39U66
39U 600x600
39
600
600
390
1735
1887
1902
1967
CKR42U66
42U 600x600
42
600
600
390
1868
2021
2036
2101
CKR44U66
44U 600x600
44
600
600
390
1960
2110
2125
2190
CKR47U66
47U 600x600
47
600
600
390
2093
2244
2259
2324
* F01 is the standard front door.
** R02 is the standard rear door for 26U and above.
38
40. TECHNICAL DRAWINGS FOR
600x600 - 26U/32U/36U/39U/42U/44U/47U
600
F01*
395
H
(Min 520)
390
(Min 45)
95
478
200
(Min 30)
111
300
Bottom view
Front view
F02
600
19”
Mounting profile
600
300
55
600
H
Front view
600
F03
55
H
Front view
H
300
Back view
Side view
600
Front view
F04
600
600
H
Top view
H= Enclosure height
Iso view
Front view
* F01 is the standard front door.
39
41. Universal Line free standing
TECHNICAL DRAWINGS FOR
600x800 - 26U/32U/36U/39U/42U/44U/47U
R02**
F01*
F02
F03
F04
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line free standing cabinets 19” 600 x 780 mm
CKR26U68
26U 600x780
26
600
780
555
1160
1309
1324
1389
CKR32U68
32U 600x780
32
600
780
555
1422
1576
1591
1656
CKR36U68
36U 600x780
36
600
780
555
1603
1754
1769
1834
CKR39U68
39U 600x780
39
600
780
555
1735
1887
1902
1967
CKR42U68
42U 600x780
42
600
780
555
1868
2021
2036
2101
CKR44U68
44U 600x780
44
600
780
555
1960
2110
2125
2190
CKR47U68
47U 600x780
47
600
780
555
2093
2244
2259
2324
* F01 is the standard front door.
** R02 is the standard rear door for 26U and above.
40
42. TECHNICAL DRAWINGS FOR
600x800 - 26U/32U/36U/39U/42U/44U/47U
395
600
F01*
200
(Min 30)
130
300
(Min 45)
91
658
(Min 701)
555
H
Bottom view
Front view
F02
600
19”
Mounting profile
780
300
55
600
H
Front view
600
F03
55
H
H
300
Front view
Side view
Back view
600
Front view
F04
780
600
H
Top view
H= Enclosure height
Iso view
Front view
* F01is the standard front door.
41
43. Universal Line free standing
SELECTION STEPS FOR
600x1000
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
roduct range name
+
U height (HHU)
+
Width&Depth (WD)
+
Rear door option (RX)
The product options have the below structure:
C
olour option (MX)
+
Front door option (FX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U6100
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U6100 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: CKR42U6100 - M02 - F01 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U6100 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page)
42
44. PART NUMBER DEFINITION FOR
600x1000
FX
MAIN PART NUMBER STRUCTURE
CKR
Product
range
Universal Line
CKR
Front door options
- HHU - WD
+
HHU
F05*
Width
&
Depth
U
height
+
F06
600
600
WD
26U
6100
36U
CKR
42U
47U
H
CKR : Universal Line free standing product range
HHU : U height
WD : Width and depth
H
Front view
Front view
F07
OPTIONS
F08
600
600
MX - FX - RX
Front
door
options
Colour
options
MX
+
FX
Rear
door
options
+
RX
F05*
R01
M02
F06
R02*
F07
R03
F08
F04
MX :
Colour options
M01= RAL 9005 black
M02= RAL 7035 light grey
FX : Front door options
F05*= Single opening tempered proof glass door with left
and right metal frame slotted, single point handled locking
F06= Single opening tempered proof glass door with
complete metal frame slotted, single point handled locking
F07= Single opening solid metal door, single point handled
locking
F08= Single opening %63 perforated door with complete
metal frame slotted, single point handled locking
RX : Rear door options
R01= Single opening solid metal rear door with barrel
type, single point lock unit
R02*= Single opening solid metal rear door with barrel
type, single point lock unit, brushed cable entry on top and
bottom
R03= Double opening % 63 perforated rear door with
complete frame, 3 point handled locking
F04= Single opening %63 perforated door with
complete metal frame slotted, single point handled locking
H
H
Front view
Front view
RX
Rear door options
R02*
300
R03
R01
F04
55
M01
Back view
Back view
Back view
Back view
H= Enclosure height
* F05 and R02 are the standard doors
43
45. Universal Line free standing
TECHNICAL DRAWINGS FOR
600x1000 - 26U/36U/42U/47U
R01
R03
F04
R02**
F05*
F06
F07
F08
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line free standing cabinets 19” 600 x 1000 mm
CKR26U6100
26U 600x1000
26
600
1000
740
1175
1309
1324
1389
CKR36U6100
36U 600x1000
36
600
1000
740
1620
1754
1769
1834
CKR42U6100
42U 600x1000
42
600
1000
740
1889
2021
2036
2101
CKR47U6100
47U 600x1000
47
600
1000
740
2110
2244
2259
2324
* F05 is the standard front door.
** R02 is the standard rear door for 26U and above.
44
46. TECHNICAL DRAWINGS FOR
600x1000 - 26U/36U/42U/47U
600
395
F05*
200
(Min 30)
150
300
878
(Min 921)
740
H
Front view
(Min 45)
106
Bottom view
1000
19”
Mounting profile
300
55
600
F06
600
H
Front view
600
F07
55
H
Front view
H
300
Back view
Side view
600
Front view
F08
1000
600
H
Top view
H= Enclosure height
Iso view
Front view
* F05 is the standard front door.
45
47. Universal Line free standing
TECHNICAL SPECIFICATIONS
TESTS AND CERTIFICATIONS
Environment
EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30,
IEC60917 and IEC60297
Industrial environment
EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297
Statical mechanical structure load test
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297,
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and flame resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and
IEC60297
Transportation
ETS300019-1-2 Class2.3
Storage
ETS300019-1-1 Class1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530, TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS
46
KEY FEATURES
Main profile (framework) has an aesthetic structure which
increases mechanical resistance, folded at an angle of 45
degrees and consisting of 6 bends for each profile. In total;
24 folds provide framework stability. Tested to provide (x,
y, z) axis resistance that meets EN 61587-1/5.2.1 and 5.2.2
and external impact resistance that meets EN 615871/5.3.3.
Bottom and upper case have a structure which increases
resistance and strength of cabinet by mono-block bended,
welded and profile-interlocking design. Profiles are
manufactured to interlock bottom and upper case with
screws. Cable access at bottom case has a sliding type
blanking access plate that would block dust inlet.
A rubber edge on the cable access plate with sliding
structure, allows fixing of cables into the cabinet without
any damage.
Rear door is manufactured with 2 cable access parts 1 ea.
with brush on top 1 ea. on bottom for 26 U and above
sizes*.
Rear door in standard configuration is a single opening
door which is removable and lockable. For options please
see the related diagrams and technical charts on pages
33-43.
Side panels have a structure that can be opened and
removed with slam latch and key and are lockable and
removable.
Front doors are a framed glass structure which is tempered,
anti-static, secure and smoked glass (4 mm thickness)
with a decorative stripe, according to EN 12150-1:2000
standard. Front door in standard configuration has left and
right metal frame structure with high density polyurethane
adhesive and screw. For front door options please see the
related diagrams and technical charts on pages 33-43.
Front door can be opened to 125 degrees, removable and
lockable with handle type locking unit.
Pagoda style vented top panel with a dedicated space of
ventilation fan module system allows easy installation of
max. 4 fans.
19”(inch) mounting angles (2ea. in front and 2ea. in rear) are
part of the cabinet interior configuration and adjustable in
depth.
Baying is possible for side by side applications without side
panels. Levelling feet are standard in shipping configuration.
The cabinet meets
EN 61587-1, IEC 60917, IEC 60297 standards, RoHS
compliancy, Gost and TSE certified.
Cabinets are manufactured in our factory which has ISO
9001: 2008 Quality Assurance System and our responsibility
for environment with ISO 14001:2004 Environmental
Management System.
* Please see related diagrams to define the difference of
rear door design between up to 26U and above 26U
48. TECHNICAL SPECIFICATIONS
Custom number
85380000 / 85381000 / 853710990019
Shipping structure
Assembled
Mounting type
Stand alone
Load carrying capacity (kg)
600
Certification on product
TSE, Gost
Surface finish
Electrostatic powder coated c/with surface treatment , 80 +/ - 5
micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11
STANDARD PRODUCT
Standard colour
RAL 7035, RAL 9005
Standard stripe colour
Orange
IP protection standard
IP20
FRONT DOOR
Shatterproof glass with left and right metal frame
Glass
4 mm thickness full-length smoked, shatterproof, tempered,
secure
Front door construction
Single door opening
Front door lock
Handle type, single point locking
Adhesive material
High density polyurethane DIN 53479, DIN 53505
Hinge system
Spring loaded
Door opening angle and swapping
125 degree, possible to swap one side to the other
SIDE PANEL
Solid metal, 1 mm left and right (2ea.)
Side panel construction
Lockable, removable c/with slam latches and lock
Side panel lock
Barrel type lock unit, single point + Slam latch (2ea)
REAR DOOR
Solid metal, 1 mm
Rear door construction
Single opening, solid metal with brushed cable entry on top and
bottom.
Rear door lock
Barrel type lock unit, single point
Hinge system
Spring loaded
Door opening angle and swapping
125 degree, possible to swap one side to the other
TOP COVER
Solid metal 1 mm
Top cover construction
Pagoda type structure provides efficient air removal
FRAMEWORK
Top and bottom base units
Solid metal 1,5 mm
Top and bottom base units construction
Completely welded corner socket system
Uprights
Solid metal, 1,5 mm
Uprights construction
Tightly fixed into top and bottom base units 6 times folded
INTERIOR PARTS
19’’ mounting angles
Solid metal, 1,5 mm
3 times folded 600x600, 600x780 / 1 time folded for 600x1000
“U” marking available 2 ea. at rear, 2 ea. at front
Pre-configured as 19’’
Zinc plated, passivated, 8-12 micron.
Adjustable in depth
C type support rails in depth
Solid metal, 1,5 mm
3 times folded, 2 ea. at left , 2 ea. at right up to 26U
3 ea. at left , 3 ea. at right 26U and higher
OPTIONS
For front and rear door options, please look at pages
33-43.
For CUSTOMIZED PRODUCTS rather than
above options, please contact sales department.
47
49. Universal Line JUMBO
free standing
SELECTION STEPS FOR
800x800
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
roduct range name
+
U height (HHU)
+
Width&Depth (WD)
+
Rear door option (RX)
The product options have the below structure:
C
olour option (MX)
+
Front door option (FX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U88
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U88 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: CKR42U88 - M02 - F09 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U88 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page)
48
50. PART NUMBER DEFINITION FOR
800x600 - 800x800
FX
MAIN PART NUMBER STRUCTURE
CKR
- HHU - WD
Product
range
Universal Line
CKR
Width
&
Depth
U
height
+
HHU
+
F09*
WD
32U
F10
780
780
86
36U
CKR
Front door options
88
39U
H
H
42U
44U
47U
CKR : Universal Line free standing product range
HHU : “U” height
WD : Width and depth
Front view
F11
Front view
F12***
780
R04**
780
780
OPTIONS
MX - FX - RX
Front
door
options
Colour
options
MX
+
FX
Rear
door
options
+
H
H
H
RX
M01
F09*
R04**
M02
F10
R05
F11
R06*
F12***
F12***
Front view
* F09 and R06 are the standard doors.
** R04 can be usable as front door also.
*** F12 used as rear door as well.
Front view
RX
R04**
Rear door options
R04**
R06*
55
300
H
55
MX : Colour options
M01= RAL 9005 black
M02= RAL 7035 light grey
FX : Front door options
F09*= Double opening tempered proof glass door with left and
right metal frame slotted, two point barrel type locking
F10= Single opening tempered proof glass door with complete
metal frame slotted, single point handled locking
F11= Single opening solid metal door, single point handled
locking
F12***= Single opening %63 perforated door with complete
metal frame slotted, single point handled locking
R04**= Double opening %63 perfore door with complete
metal frame, 3 point handled locking
RX : Rear door options
R06*= Double opening complete metal door with brushed cable
entry, barrel type single point lock unit.
R04**= Double opening %63 perforated door with complete
metal frame, 3 point handled locking
R05= Single opening solid metal rear door with barrel type,
single point lock unit
F12***= Single opening %63 perforated door with complete
metal frame slotted, single point handled locking
Front view
300
Back view
R05
Back view
Back view
F12***
Back view
H= Enclosure height
49
51. Universal Line JUMBO
TECHNICAL DRAWINGS FOR
800x600 - 32U/36U/39U/42U/44U/47U
F12***
R05
R04**
R06*
F09*
F10
F11
R04**
F12***
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line JUMBO cabinets 19” 780 x 600 mm
CKR32U86
32U 780x600
32
780
600
365
1422
1576
1591
1656
CKR36U86
36U 780x600
36
780
600
365
1603
1754
1769
1834
CKR39U86
39U 780x600
39
780
600
365
1735
1887
1902
1967
CKR42U86
42U 780x600
42
780
600
365
1868
2021
2036
2101
CKR44U86
44U 780x600
44
780
600
365
1960
2110
2125
2190
CKR47U86
47U 780x600
47
780
600
365
2093
2244
2259
2324
* F09 and R06 are the standard doors.
** R04 is usable as front door also.
*** F12 is usable as rear door also.
50
52. TECHNICAL DRAWINGS FOR
800x600 - 32U/36U/39U/42U/44U/47U
F09*
515
F10
780
300
478
(Min 408)
365
55
H
(Min 138)
141
200
780
(Min 50)
90
300
19”
Bottom view
Front view
Mounting profile
780
Front view
F11
780
300
55
600
H
H
H
H
Front view
F12
55
780
Front view
300
Side view
H
Back view
Front view
780
R04
55
300
600
780
H
Top view
H= Enclosure height
Iso view
Front view
* F09 is the standard door.
51
53. Universal Line JUMBO
TECHNICAL DRAWINGS
800x800 - 32U/36U/39U/42U/44U/47U
F12***
R05
R04**
R06*
F09*
F10
F11
R04**
F12***
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line JUMBO cabinets 19” 780 x 780 mm
CKR32U88
32U 780x780
32
780
780
550
1422
1576
1591
1656
CKR36U88
36U 780x780
36
780
780
550
1603
1754
1769
1834
CKR39U88
39U 780x780
39
780
780
550
1735
1887
1902
1967
CKR42U88
42U 780x780
42
780
780
550
1868
2021
2036
2101
CKR44U88
44U 780x780
44
780
780
550
1960
2110
2125
2190
CKR47U88
47U 780x780
47
780
780
550
2093
2244
2259
2324
* F09 and R06 are the standard doors.
** R04 is usable as front door also
*** F12 is usable as rear door also.
52
54. TECHNICAL DRAWINGS FOR
800x800 - 42U/47U
515
300
(Min 40)
95
F10
780
(Min 720)
550
780
H
H
(Min 130)
131
658
300
85
300
F09*
Front view
19”
Bottom view
Mounting profile
Front view
F11
780
780
300
55
780
H
H
H
Front view
F12
55
780
Front view
300
Side view
Back view
H
780
Front view
R04
55
780
300
780
H
Top view
H= Enclosure height
Iso view
Front view
* F09 is the standard front door.
53
55. Universal Line JUMBO free standing
SELECTION STEPS FOR
800x1000
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and
‘’Options’’ sections.
The below example explains how to select the right options for your needs.
The product part number has the below structure:
P
roduct range name
+
U height (HHU)
+
Width&Depth (WD)
+
Rear door option (RX)
The product options have the below structure:
C
olour option (MX)
+
Front door option (FX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: CKR42U8100
Step 2
Please choose the colour from the table and place it after the part number.
For example: CKR42U8100 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: CKR42U8100 - M02 - F09 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: CKR42U8100 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page)
54
56. PART NUMBER DEFINITION FOR
800x1000
FX
MAIN PART NUMBER STRUCTURE
CKR
- HHU - WD
Product
range
Universal Line
CKR
Front door options
Width
&
Depth
U
height
+
HHU
+
WD
H
H
Front view
780
47U
CKR : Universal Line product range
HHU : “U” height
WD : Width and depth
OPTIONS
F10
780
8100
42U
CKR
F09*
F11
Front view
F12***
780
R04**
780
780
MX - FX - RX
Front
door
options
Colour
options
MX
+
FX
Rear
door
options
+
H
RX
M01
F09*
R04**
M02
F10
R05
F11
R06*
F12
H
F12***
Front view
Front view
Front view
R04**
RX
MX : Colour options
M01= RAL 9005 black
M02= RAL 7035 light grey
FX : Front door options
F09*= Double opening tempered proof glass door with left and
right metal frame slotted, two point barrel type locking
F10= Single opening tempered proof glass door with complete
metal frame slotted, single point handled locking
F11= Single opening solid metal door, single point handled
locking
F12***= Single opening %63 perforated door with complete
metal frame slotted, single point handled locking
R04**= Double opening %63 perforated door with complete
metal frame, 3 point handled locking
RX : Rear door options
R05= Single opening solid metal rear door with barrel type,
single point lock unit
R04**= Double opening %63 perforated door with complete
metal frame, 3 point handled locking
R06*= Double opening complete metal door with brushed cable
entry, barrel type single point lock unit.
F12***= Single opening %63 perforated door with complete
metal frame slotted, single point handled locking
Rear door options
* F09 and R06 are the standard doors
** R04 is usable as front door also.
*** F12 is usable as rear door also.
R04**
R06*
55
300
55
H
300
Back view
R05
Back view
Back view
F12***
Back view
H= Enclosure height
55
57. Universal Line JUMBO
TECHNICAL DRAWINGS FOR
800x1000 - 42U/47U
F12***
R05
R04**
R06*
F09*
F10
F11
R04**
F12***
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
Universal Line JUMBO cabinets 19” 780 x 1000 mm
CKR42U8100
42U 780X1000
42
780
1000
740
1889
2021
2036
2101
CKR47U8100
47U 780X1000
47
780
1000
740
2110
2244
2259
2324
* F09 and R06 are the standard doors.
** R04 is usable as front door also.
*** F12 is usable as rear door also.
56
58. TECHNICAL DRAWINGS FOR
800x1000 - 42U/47U
515
300
(Min 26)
120
F10
780
780
(Min 852)
740
(Min 118)
136
878
300
85
300
F09*
Bottom view
H
H
Front view
19”
Mounting profile
Front view
F11
780
780
1000
55
300
H
H
H
Front view
55
F12
780
300
Front view
Side view
Back view
H
780
Front view
R04
780
1000
300
55
H
Top view
H= Enclosure height
Iso view
Front view
* F09 is the standard front door.
57
59. Universal Line JUMBO
TECHNICAL SPECIFICATIONS
TESTS AND CERTIFICATIONS
Environment
EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30,
IEC60917 and IEC60297
Industrial environment
EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297
Statical mechanical structure load test
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297,
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and flame resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and
IEC60297
Transportation
ETS300019-1-2 Class2.3
Storage
ETS300019-1-1 Class1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530, TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS
58
KEY FEATURES
Main profile (framework) has an aesthetic structure which
increases mechanical resistance, folded at an angle of 45
degrees and consisting of 6 bends for each profile. In total;
24 folds provide framework stability.Tested to provide (x, y,
z) axis resistance that meets EN 61587-1 / 5.2.1 and 5.2.2,
and external impact resistance that meets
EN 61587-1 / 5.3.3.
Bottom and upper case have a structure to increase
resistance and strength of cabinet by mono block bended,
welded and profile-interlocking design. Profiles are
manufactured to interlock bottom and upper case with
screws.The bottom case providing cable access is fitted
with a sliding blanking access plate to prevent dust.
A rubber edge on the cable access plate and sliding
structure, allows cables to be placed into the cabinet and
fixed inside with no damage. Additionally both on top and
bottom, there are brushed cable entry plates for mass
cabling needs.
Rear door is manufactured with 2 cable access part top/
bottom with brush.
Rear door in standard configuration is a double opening
door which is removable and lockable. For options please
see the related diagrams and technical charts in pages 4955.
Side panels have a structure that can be opened and
removed with slam latch and key and are lockable and
removable.
Front doors are a framed glass structure which is tempered,
anti-static, secure and smoked glass (4 mm thickness)
with a decorative stripe, according to EN 12150-1:2000
standard. Front door in standard configuration has left and
right metal frame structure with high density polyurethane
adhesive and screw and double opening.
For options please see the related diagrams and technical
charts in pages 49-55.
Front door is a double openning door which can be opened
to 125 degrees, removable and lockable with handle type
locking unit.
Pagoda style vented top panel with a dedicated space of
ventilation fan module system allows easy installation of
max. 4 fans.
19”(inch) mounting angles (2 ea. in front and 2 ea. in rear)
are part of the cabinet interior configuration and adjustable
in depth.
Baying is possible for side by side applications without side
panels.. Levelling feet are standard in shipping configuration.
The cabinet meets EN 61587-1, IEC 60917, IEC 60297
standards, RoHS compliancy, Gost and TSE certified.
Cabinets are manufactured in our factory which has
ISO 9001: 2008 Quality Assurance System and our
responsibility for enviroment with ISO 14001: 2004
Environmental Management System.
60. TECHNICAL SPECIFICATIONS
Custom number
85380000 / 85381000 / 853710990019
Shipping structure
Assembled
Mounting type
Stand alone
Load carrying capacity (kg)
600
Certification on product
TSE, Gost
Surface finish
Electrostatic powder coated c/with surface treatment , 80 +/ - 5
micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11
STANDARD PRODUCT
Standard colour
RAL 7035, RAL 9005
Standard stripe colour
Orange
Baying
Possible with baying kit for side by side applications without side
panels
IP protection standard
IP20
FRONT DOOR
Shatterproof glass with left and right metal frame
Glass
4 mm thickness full-length smoked, shatterproof, tempered,
secure
Front door construction
Double opening door
Front door lock
2 point locking barrel type
Adhesive material
High density polyurethane DIN 53479, DIN 53505
Hinge system
Spring loaded
Door opening angle and swapping
125 degree
SIDE PANEL
Solid metal, 1 mm left and right (2 ea.)
Side panel construction
Lockable, removable c/with slam latches and lock
Side panel lock
Barrel type lock unit, single point + Slam latch (2 ea)
REAR DOOR
Solid metal, 1 mm
Rear door construction
Double door opening, lockable, removable
Rear door lock
Barrel type lock unit, single point
Hinge system
Spring loaded
Door opening angle and swapping
125 degree
TOP COVER
Solid metal 1,2 mm
Top cover construction
Pagoda type, allows efficient air removal
FRAMEWORK
Top and bottom base units
Solid metal 1,5 mm
Top and bottom base units construction
Completely welded corner socket system
Uprights
Solid metal, 1,5 mm
Uprights construction
Tightly fixed into top and bottom base units 6 times folded
INTERIOR PARTS
19’’ mounting angles
Solid metal, 1,5 mm
3 times folded 800x600, 800x800 / 1 time folded for 800x1000
“U” marking available
2 ea. at rear, 2 ea. at front
Pre-configured as 19’’
Zinc plated, passivated, 8-12 micron.
Adjustable in depth
Omega type support rails in depth
Solid metal, 1,5 mm
3 times folded
2 ea. at left , 2 ea. at right up to 26U
3 ea. at left , 3 ea. at right 26U and higher
OPTIONS
For the front and rear door options, please look at pages
49-55.
For CUSTOMIZED PRODUCTS rather than
above options, please contact sales department.
59
61. Universal Line JUMBO
Accessories
SPECIAL ACCESSORIES* FOR JUMBO
Teleskopic cable trunking
Designed to protect and hide cable bundles coming from
the ceiling. Since the height between ceiling and cabinet is
variable, it is manufactured as telescopic to fit all dimensions.
Coming complete with cover which when closed gives a
professional look.
Vertical cable management channels
(left and right)
Designed to manage large patch cable bundles in front of
the cabinet. It is installed through the height of the cabinet,
and each “U” dimension, there is a hole to pass horizontal
patch cables on vertical axis. A spring hinged cover in front
of the vertical cable management panel integral with slam
latch.The cover protect and hide all cable bundles. When
it is closed, it gives a professional look. Labour costs are
reduced by %20 and is a time saving system.
Vertical cable management trunking
Designed to carry large cable bundles through the vertical
axis of the cabinet. From top to bottom, it is continuous
with the height of cabinet. Bottom edge of the trunking
fits into the cabinet bottom cable entry, top edge of the
trunking fits into the cabinet top cable entry. It has holes
for cable access for horizantal axis. It is punched in a shape
to tie the cables. Since it has a sliding cover on the trunking,
cable bundles are hidden and protected. When closed, it
offers a chic looking finish.
*See accessories for product part numbers, definitions and please contact sales department.
Professional cabling solutions
with JUMBO
Left and right cable management panels
hide and protect all networking cables as
well as providing a professional looking
finish.
Double opening rear doors provide space saving
between cabinet and wall.
60
62. UNIVERSAL LINE JUMBO FEATURES
Perforated, vented
Pagoda-style top
providing maximum
protection against dust
Front door with
integrated locking
mechanism for
added security.
Side panel comes with
snap closures and locks
providing security, whilst
allowing four-way access
to the equipment.
Sliding access panel on
the bottom for cable
entry and a brush entry
on the rear panel that
can be positioned on the
top or bottom
61
63. Universal Line PCcase free standing
600x800 - 36U
STANDARD DIMENSIONS:
Height: 36U
Width: 600 mm
Depth: 780 mm
STANDARDS:
ISO 9001: 2008 Quality Management Systems
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for
electronic equipments)
Overall cabinet dimensions to IEC 297-2
COLOUR:
RAL 9005 black
RAL 7035 light grey
• 19”
• FITS YOUR DECOR AND ENVIRONMENT
• SECURE AND STURDY
• EASY TO MAINTAIN AND LARGE INNER
VOLUME
• DUST PROOF
• AIR CIRCULATION WITH VENTED FILTERS
62
PCcase is ideal for office, factory, workshop, storage,
store, gas stations and laboratories etc. as server
housing. It protects your servers and devices against
dust, humidity, hot/cold air but most important that
against unauthorized peoples. Servers, all kind of PC’s,
monitors, keyboards, UPS’s, switches and networking
products can easily be placed in it.
Its agronomy provides the keyboards at hands level and
monitor is at eye level.
64. 600x800 - 36U
FEATURES
PCccase cabinets match all features defined for
Universal Line as main construction.
It has 3 sections;
1st compartment: Screen section
11U space covered, (not 19’’, equipped with a fixed
shelf which should be base for the screen unit).
2nd Compartment: Keyboard section
3U space covered (not 19’’, equipped with a specific
sliding shelf integrated with mouse housing and
platform).
3rd Compartment: Device section
19” 22U usable (19’’, 22U rail allowing use of all
standard accessories to mount all kind of devices
printers, UPS, server or any LAN/WAN devices...)
All compartments are lockable.
Both side doors are lockable, removable, and
openable.
Side doors have filtered and vented air circulation
trays that allow air circulation or air entry.
It is possible to use together with cooling fans which
also has filtered and vented tray on top that allow
air circulation.
Bottom section has two door options:
Glass door or solid metal door.
63
65. Universal Line PCcase
TECHNICAL DRAWINGS
600x800 - 36U
Exploded view
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
36U 600x780 mm PCcase, metal door
section at bottom
Height:
vertical
mounting
profile (mm)
PCCASE36M
Depth: max
mounting
profile (mm)
36U 600x780 mm PCcase, glass door
section at bottom
Depth:
overall
(mm)
PCCASE36
64
Product
definition
(mm)
Width:
overall
(mm)
Part
number
U
Size
Universal Line PCcase cabinets 19” 600 x 780 mm
36
600
780
555
1603
1766
1781
1846
66. TECHNICAL DRAWINGS FOR
600x800 - 36U
395
600
(Min 30)
91
1746
(Min 701)
555
658
200
(Min 30)
130
300
19”
Bottom view
Mounting profile
600
780
1746
Front view with glass door
600
Front view
Side view
Back view
1746
600
780
302
350
Front view with metal door
Top view
Iso view
65
67. Universal Line
free standing accessories
FREQUENTLY USED ACCESSORIES SELECTION TABLE FOR Universal Line
Estap has a wide range of accessories: Fixed shelves, heavy duty fixed shelves, sliding shelves, fans, cooling units,
vertical cable managements, cable rings, organisers, trays, plinth and so on...
* See the other accessories and part number definitions on pages 173-213.
* Please state colour choice in your orders.
M01=RAL 9005 black and M02= RAL 7035 light grey
Frequently used accessories selection table
Universal Line /
Shelves
part numbers
Fixed shelves
Enclosure Sizes*
PCcase
600x800
600x1000
800x600
800x800
800x1000
M44SBR80 M44SBR60 M44SBR80 M44SBR100 M44SBR60 M44SBR80 M44SBR100
Heavy duty fixed shelves
Sliding shelves
600x600
-
-
-
M55SR720
M44HRK80 M44HRK60 M44HRK80
Heavy duty sliding shelves
-
-
-
-
-
-
M44HRK60 M44HRK80
M55HR720
M55SR720
-
-
-
M55HR720
Universal Line /
Fan units
part numbers
PCcase
600x600
600x800
600x1000
800x600
800x800
800x1000
2 Fan unit with on/off switch
M44HV2F
M44HV2F
M44HV2F
M44HV2F
M44HV2F
M44HV2F
M44HV2F
4 Fan unit with on/off switch
M44HV4F
M44HV4F
M44HV4F
M44HV4F
M44HV4F
M44HV4F
M44HV4F
2 Fan unit with thermostat unit
M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT
M44HV2FT
4 Fan unit with thermostat unit
M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT
M44HV4FT
Universal Line /
Cable management
part numbers
1U cable management
panel (5 rings)
Vertical cable management
Universal Line /
PDU
part numbers
Enclosure Sizes*
Enclosure Sizes*
PCcase
600x600
600x800
600x1000
800x600
E44ORG1U E44ORG1U E44ORG1U E44ORG1U E44ORG1U
-
-
-
-
800x800
800x1000
E44ORG1U
E44ORG1U
M44ORGxxU M44ORGxxU M44ORGxxU
Enclosure Sizes*
PCcase
600x600
600x800
600x1000
800x600
800x800
800x1000
6 way PDU with 1x16A
CCT breaker,1U
M446AL
M446AL
M446AL
M446AL
M446AL
M446AL
M446AL
9 way PDU with 1x16A
CCTbreaker, 2U
M449ALC
M449ALC
M449ALC
M449ALC
M449ALC
M449ALC
M449ALC
800x600
800x800
800x1000
Universal Line /
Castor
part numbers
Castor group
Fixings/ cagenut, screw, washer
(1set=20 pcs.)
66
Enclosure Sizes*
PCcase
600x600
600x800
600x1000
M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1
KFS6X15
* Please check drawing pages for cabinet sizes.
KFS6X15
KFS6X15
KFS6X15
KFS6X15
KFS6X15
M22TKGR1
KFS6X15
68. EUROline free standing
Reduce
%ip5e0t
sh m n
*
cost
• Real flatpack design
• Max. 10 min** for assembly
• Easy to carry and transport
• Easy to maintenance
• High volume capacity for large
cable bundles
* Mixed quantity and mixed size
** Measured values by Estap. It can change
according to size of the enclosure
67
69. EUROline free standing
600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000
EUROline free standing enclosures
22U 26U 32U 36U
42U
600 x 600*
42U
600 x 1000*
32U 36U
42U
800 x 800*
42U
800 x 1000*
600 x 800*
Openable, lockable,
removable side panels,
front and rear doors
• 19”
• MODULAR STRUCTURE
• READY FOR ASSEMBLY
• STURDY, RUGGED STEEL CONSTRUCTION
• REDUCE THE SHIPMENT COST
• FLATPACK
* Please check drawing pages for cabinet sizes.
68
70. 600x600 - 600x800 - 600x1000 - 800x800 - 800x1000
STANDARD DIMENSIONS:
Heights: 22U, 26U, 32U, 36U, 42U
Width: 600 mm
Depth: 645 mm and 825 mm
LOAD CARRYING CAPACITY: 400 kg
Heights: 42U
Width: 600 mm
Depth: 1005 mm
RAL 7035 light grey
Heights: 32U, 36U, 42U
Width: 780 mm
Depth: 825 mm
Height: 42U
Width: 780 mm
Depth: 1005 mm
COLOUR:
RAL 9005 black
STANDARDS:
ISO 9001: 2008 Quality Management Systems
ISO 14001: 2004 Environmental Management System
19” mounting to IEC 297-1
EN 61587-1 mechanical structures (cabinets for
electronic equipment)
Overall cabinet dimensions for IEC 297-2
KEY FEATURES
• High quality production
• Aesthetic look
• Sturdy, rugged steel construction
• Openable, lockable, removable side panels, front and rear
doors.
• Secure, tempered front door, with left&right metal frames,
and handle type lock.
• Easy to maintain, high volume capacity for large cable bundles.
• Upper case is suitable for fan units and brushed cable entry.
• Welded corners and sturdy construction.
• Bottom case is completely open for large cable entries.
Bottom plate with sliding type Estap standard cable entry, can
be used to close case.
• Rugged steel for 19” mounting angles
• Reduce shipment costs %50*
• Easy to transport
• Strong protection against transport damages
• Easy to assemble
• After mounting, cardboard packaging and wooden pallets
may be retained and reused for future shipments.
* Mixed quantity and mixed size
69
71. EUROline free standing
SELECTION STEPS FOR
600x600 - 600x800
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and
‘’Options’’ sections.
The below example explains how to select the right options.
The product part number has the below structure:
P
roduct range name
+
U height (HHU)
+
Width&Depth (WD)
+
Rear door option (RX)
The product options have the below structure:
C
olour option (MX)
+
Front door option (FX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: EU42U68
Step 2
Please choose the colour from the table and place it after the part number.
For example: EU42U68 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: EU42U68 - M02 - F18 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: EU42U68 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page)
70
72. PART NUMBER DEFINITION
600x600 - 600x800
FX
MAIN PART NUMBER STRUCTURE
EU
Front door option
- HU - WD
H
Product
range
EUROline
EU
Width
&
depth
U
height
+
HHU
22U
+
F18
WD
66
68
26U
EU
600
32U
36U
42U
EU : EUROline free standing product range
HHU : “U” height
WD : Width and depth
H
OPTIONS
MX - FX - RX
Front
door
option
Colour
MX
M01
+
FX
F18
Rear
door
option
+
RX
Front view
R10
RX
M02
Rear door option
600
R10
MX : Colour options
RAL 9005 black
M01=
RAL 7035 light grey
M02=
FX : Front door option
Single opening shatter proof glass door with left
F18=
and right metal frame slotted, single point handled
locking
H
RX : Rear door option
Single opening solid metal rear door with
R10=
barrel type lock unit, single point
H= Enclosure height
Back view
71
74. TECHNICAL DRAWINGS FOR
600x600 - 22U/26U/32U/36U/42U
F18
600
H
(Min 93,5)
155
566
(Min 455)
331,5
(Min 91,5)
153
521
19”
Bottom view*
Note: *Bottom is empty, the top of the
Front view
Mounting profile
enclosure appears
600
645
566
521
300
200
H
Bottom view*
Note: * Bottom cover plate is an optional
accessory
Side view
645
600
300
Back view
72
Front view
Top view
H= Enclosure height
Iso view
73
75. EUROline free standing
TECHNICAL DRAWINGS FOR
600x800 - 22U/26U/32U/36U/42U
R10
F18
*
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
EUROline free standing cabinets 19” 600 x 825 mm
EU22U68
22U 600x825
22
600
825
511,5
1070
1135
1150
1215
EU26U68
26U 600x825
26
600
825
511,5
1245
1310
1325
1395
EU32U68
32U 600x825
32
600
825
511,5
1515
1575
1590
1655
EU36U68
36U 600x825
36
600
825
511,5
1700
1755
1770
1840
EU42U68
42U 600x825
42
600
825
511,5
1960
2025
2040
2110
* The bottom cover plate is an optional accessory.
74
76. TECHNICAL DRAWINGS FOR
600x800 - 22U/26U/32U/36U/42U
521
F18
(Min 635)
511,5
746
(Min 91,5)
153
600
(Min 91,5)
153
H
19”
Bottom view*
Mounting profile
Note: * Bottom is empty, the top of the
enclosure appears
521
825
746
200
600
Front view
300
H
Bottom view*
Note: * Bottom cover plate is an optional
accessory
Side view
Front view
Back view
825
72
600
300
Top view
H= Enclosure height
Iso view
75
77. EUROline free standing
SELECTION STEPS FOR
600x1000
STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and
‘’Options’’ sections.
The below example explains how to select the right options.
The product part number has the below structure:
P
roduct range name
+
U height (HHU)
+
Width&Depth (WD)
+
Rear door option (RX)
The product options have the below structure:
C
olour option (MX)
+
Front door option (FX)
HOW TO SELECT THE OPTIONS
Step 1 - Please choose product part number.
For example: EU42U61
Step 2 - Please choose the colour from the table and place it after the part number.
For example: EU42U61 - M02 (MX=Look at the MX colour options on the next page)
Step 3 - Please choose the front door from the table and place it after MX colour.
For example: EU42U61 - M02 - F18 (FX= Look at the FX front door options on the next page)
Step 4 - Please choose the rear door from the table and place it after FX front door option.
For example: EU42U61 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page)
76
78. PART NUMBER DEFINITION FOR
600x1000
FX
MAIN PART NUMBER STRUCTURE
Front door options
EU - HHU - WD
Product
range
EUROline
EU
Width
&
depth
U
height
+
EU
HHU
+
WD
600
61
42U
EU : EUROline free standing product range
HHU : “U” height
WD : Width and depth
F21
600
F18*
H
H
OPTIONS
MX - FX - RX
Front
door
options
Colour
options
MX
+
FX
Front view
Front view
Rear
door
options
+
RX
M01
F18*
R10**
M02
F21
R07
RX
RX
Rear door options
Rear door options
MX : Colour options
RAL 9005 black
M01=
RAL 7035 light grey
M02=
FX : Front door options
Single opening shatter proof glass door with
F18*=
left and right metal frame slotted, single point handled
locking
Single opening %63 perforated front door,
F21=
full slotted frame, single point handled locking
RX : Rear door options
Single opening solid metal rear door with
R10**=
barrel type lock unit, single point locking
Double opening complete framed % 63
R07=
perforated front door, 3 point handled locking
600
R10**
600
H
Back view
R07
H
Back view
H= Enclosure height
H= Enclosure height
* F18 is the standard front door.
** R10 is the standard rear door.
77
79. EUROline free standing
TECHNICAL DRAWINGS FOR
600x1000 - 42U
R07
R10**
F21
F18*
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
EUROline free standing cabinets 19” 600 x 1005 mm
EU42U61
42U 600x1005
42
600
1005
702,5
1960
2025
2040
2110
* F18 is the standard front door.
** R10 is the standard rear door.
78
80. TECHNICAL DRAWINGS FOR
600x1000 - 42U
600
522
(Min 85,5)
147
522
(Min 825,5)
702,50
926
463
(Min 86,5)
148
F18*
Bottom view*
Note: *Bottom is empty, the top of the
enclosure appears
H
19”
Mounting profile
600
Front view
1005
600
H
F21
H
Side view
Front view
Back view
Front view
600
1005
72
300
Top view
Iso view
H= Enclosure height
* F18 is the standard front door.
79
81. EUROline free standing
SELECTION STEPS FOR
800x800 - 800x1000
STEPS TO SELECT RIGHT FREE STANDING ENCLOSURE
In addition to Estap product part numbers, the options mentioned on the next page are to supply the right
definition to meet your requirements.
Each wall mounted and free standing enclosure section on the catalogue, has a ‘’Main part numbers’’ and
‘’Options’’ sections.
The below example explains how to select the right options.
The product part number has the below structure:
P
roduct range name
+
U height (HHU)
+
Width&Depth (WD)
+
Rear door option (RX)
The product options have the below structure:
C
olour option (MX)
+
Front door option (FX)
HOW TO SELECT THE OPTIONS
Step 1
Please choose product part number.
For example: EU42U88 or EU42U81
Step 2
Please choose the colour from the table and place it after the part number.
For example: EU42U88 - M02 (MX=Look at the MX colour options on the next page) or
EU42U81 - M02 (MX=Look at the MX colour options on the next page)
Step 3
Please choose the front door from the table and place it after MX colour.
For example: EU42U88 - M02 - F20 (FX= Look at the FX front door options on the next page) or
EU42U81 - M02 - F20 (FX= Look at the FX front door options on the next page)
Step 4
Please choose the rear door from the table and place it after FX front door option.
For example: EU42U88 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page) or
EU42U81 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page)
80
82. PART NUMBER DEFINITION
800x800 - 800x1000
FX
MAIN PART NUMBER STRUCTURE
EU - HHU - WD
Product
range
EUROline
EU
Width
&
depth
U
height
+
HHU
32U
Front door options
+
780
H
H
81
EU : EUROline free standing product range
HHU : “U” height
WD : Width and depth
Front view
Front view
RX
OPTIONS
MX - FX -
Rear door options
RX
780
Front
door
options
Colour
options
MX
+
FX
F19*
88
42U
42U
780
WD
36U
EU
F20**
R12***
Rear
door
options
+
RX
M01
F20**
R12***
M02
F19*
R11
R08*
R08*
H
F19*
MX : Colour options
RAL 9005 black
M01=
RAL 7035 light grey
M02=
Back view
780
FX : Front door options
Double opening shatter proof glass door with
F20**=
left and right metal frame slotted, 3 point handled
locking
Single opening %63 perforated front door,
F19=
full slotted frame, single point handled locking
Double opening complete framed %63
R08*=
perforated front door, 3 point handled locking
RX : Rear door options
Double opening metal rear door with
R12***=
3 point handled locking
Single opening solid metal rear door with
R11=
barrel type lock unit, single point lock unit
Double opening complete framed %63
R08*=
perforated front door, 3 point handled locking
F19*= Single opening %63 perforated front door,
full slotted frame, single point handled locking
H
Back view
R08*
780
H
H= Enclosure height
* R08 and F19 can be used as both front and rear door.
** F20 is the standard front door.
*** R12 is the standard rear door.
R11
Back view
81
83. EUROline free standing
TECHNICAL DRAWINGS FOR
800x800 - 32U/36U/42U
F19**
R08**
R11
R12****
F19**
F20***
R08**
*
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
EUROline free standing cabinets 19” 780 x 825 mm
EU32U88
32U 780x825
32
780
825
511,5
1515
1525
1540
1655
EU36U88
36U 780x825
36
780
825
511,5
1630
1755
1770
1840
EU42U88
42U 780x825
42
780
825
511,5
1960
2025
2040
2110
* The bottom cover plate is optional.
** R08 and F19 can be used as both front and door rear door.
*** F20 is the standard front door.
**** R12 is the standard rear door.
82
84. TECHNICAL DRAWINGS FOR
800x800 - 32U/36U/42U
780
F20*
701
(Min 725)
511,5
H
(Min 47,5)
154
776
746
(Min 44,5)
151
513
19”
Bottom view*
Mounting profile
Note: *Bottom is empty, the top of the
Front view
enclosure appears
780
701
825
780
F19
200
300
746
H
H
Bottom view
Note: Bottom cover plate is an optional
accessory
Front view
Side view
Back view
Front view
780
Top view
H= Enclosure height
747
300
300
R08
72
702
H
Iso view
Front view
* F20 is the standard front door.
83
85. EUROline free standing
TECHNICAL DRAWINGS FOR
800x1000 - 42U
F19**
R08**
R12****
R11
F19**
F20***
R08**
*
Exploded view
Part
number
Product
definition
(mm)
U
Size
Width:
overall
(mm)
Depth:
overall
(mm)
Depth: max
mounting
profile (mm)
Height:
vertical
mounting
profile (mm)
Height:
without
levelling feet
(mm)
Height:
with
levelling feet
(mm)
Height:
with casters
(mm)
EUROline free standing cabinets 19” 780 x 1005 mm
EU42U81
42U 780x1005
42
780
1005
704,5
1960
2025
2040
2110
* The bottom cover plate is optional.
** R08 and F19 can be used as both front and door rear door.
*** F20 is the standard front door.
**** R12 is the standard rear door.
84
86. TECHNICAL DRAWINGS FOR
800x1000 - 42U
701
513
780
H
(Min 40)
146,5
926
(Min 784,5)
704,50
(Min 40)
146,5
F20*
Bottom view*
Note: *Bottom is empty, the top of the
enclosure appears
19”
Mounting profile
Front view
1005
780
780
F19
H
H
Front view
Side view
Back view
780
702
Front view
780
R08
72
300
H
300
927
1005
55
H= Enclosure height
Top view
Iso view
Front view
* F20 is the standard front door.
85
87. EUROline free standing
TECHNICAL SPECIFICATIONS
TESTS AND CERTIFICATIONS
Environment
EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30,
IEC60917 and IEC60297
Industrial environment
EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and
IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297
Statical mechanical structure load test
EN61587-1 / 5.2.1, IEC60917 and IEC60297
Statical mechanical structure stability
EN61587-1 / 5.2.2, IEC60917 and IEC60297
Dynamic load, vibration and mechanical stroke
EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297,
IEC62208
Grounding continuity
EN61587-1 / 6.2, IEC60917 and IEC60297
Fire and Flame Resistance
EN61587-1 / 6.3, IEC60917 and IEC60297
Corrosion
ISO9227 and ASTM B 117-85, IEC60917 and IEC60297
IP protection degree
IP00.When bottom cover plate is used, it becomes IP20
IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and
IEC60297
Transportation
ETS300019-1-2 Class2.3
Storage
ETS300019-1-1 Class1.2
Security
EN60950_LVD
PURCHASED PRODUCT CERTIFICATIONS
Sheet steel
DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS
Electrostatic powder coating
ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5,
ISO 8130-3, RoHS
Fan
ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS
Glass
ISO 9001, EN 12150 – 1: 2000 tempered and secure
Fixings
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933,
RoHS
Castors
TS EN 12530, TS EN 12532, RoHS
Lock
DIN 1743, DIN 53571, RoHS
86
KEY FEATURES
Main profile vertical (framework) has a structure which
increases mechanical resistance with aesthetic appearance and
a specially closed profile system of 30x30 mm from automation
industry. Folded with an angle of 90 degree:The corner joints
are welded with 4 fold connection brackets.The main profile
vertical (framework) connects to top and bottom case with
heavy duty 5 fold bended profile system. A total of 20 folds
provide stability for the top and bottom case. Additionally,
at 600x1000 and 800x1000 mm sizes a 5 fold (bend surface)
bracket system provides additional stability, providing a 25 fold
(bent surface) design criteria for the frame. Manufactured and
tested to provide axial (x, y, z) resistance that meets EN 61587-1
/ 5.2.1 and 5.2.2, and external impact resistance that meets EN
61587-1 / 5.3.3.
Using a folded profile system for structure, the bottom and
upper case are connected to the vertical profile system using
heavy duty screws which provide modularity. Bottom case if
fully open for large cable bundles to be placed; if required to
close the bottom, a cover plate can be purchased as an optional
accessory with sliding type edged cable entry panel.
The rubber edge on the cable access plate and sliding structure,
allows cables to be placed into the cabinet and fixed inside with
no damage.
For W=600 mm enclosure rear door is single solid metal,
removable and lockable. Integral locking is single point barrel
type locking system. For W=800 mm enclosure rear door in
double opening, complete metal and 3 point handled locking.
For options please see the related diagrams and technical charts
On pages 71-77-81.
Rear doors can be opened up to 220 degrees.
Side panels have a structure that can be opened and removed
with a key and are lockable and removable. Side panels are
consist of 2 piece side panels on each side for D=1000 mm
range due to easy handling and maintanence needs. Original
functional side panel is lockable and removable as mentioned
above; the smaller side panel is fixed from inner side with
screws.Within this engineering construction the original
functional side panel becomes easy to carry while installation
and maintanance is in process.
Front doors are single opening, left and right metal framed glass
door, single point handled locking on the W=600 mm series,
front doors are double opening, left and right metal framed glass
door, 3 point handled locking on the W=800 mm series, front
door can be opened up to 220 degrees, removable and lockable
with handle type locking unit. For options please see the related
diagrams and technical charts on pages 71-77-81.
Vented top panel housing with a dedicated space for ventilation,
fan module system allows easy installation of max. 4 fans from
top.
19”(inch) mounting angles (2 ea. in front and 2 ea. in rear) are
part of cabinets interior configuration and adjustable in depth.
Baying is possible for side by side applications. Levelling feet are
standard in shipping configuration.The cabinet meets
EN 61587-1, IEC 60917, IEC 60297 standards RoHS compliancy,
Gost and TSE certified.
Cabinets are manufactured in our factory which has
ISO 9001: 2008 Quality Assurance System and our responsibility
for environment with ISO 14001:2004 Environmental
Management System.