3. Power Consumption / Dimmability
Dialight
Energy savings
Replace 400W conventional light source with 150W LED High Bay for immediate
energy savings of 60%, even more when you use dimming and proximity sensors.
Dimming
Dimming options for LEDs include STEP dimming for specified light level percentages
or variable dimming for custom light output levels determined by the
installer/customer. A special ballast is required to dim fluorescent lamps.
Bans
“Under the terms of the National Energy Policy Act of 1992 (EPACT) and similar
legislation in Canada many of the full wattage T12 lamps can no longer be
manufactured due to their relative low efficacy and/or poor color characteristics” (The
Lighting Handbook, IES, 10th ed., 7.32).
Light Source
Dimmability
Fluorescent
40 – 264
Requires Special Ballast
LED
3
Fixture
Watts
8 – 170
Yes
4. Lumen Per Watt Efficiency
Dialight
Light Source
Fluorescent
40 – 100
LED
4
Lumens/watt
Up to 150
5. Lifetime / Lumen Maintenance
Dialight
Light Source
Fluorescent
6 – 45
LED
5
Lifetime in Hours (x1000)
100+
6. Colour Quality
Dialight
Colour Rendering Index:
“A measure of the degree of colour shift that a set of test-colour samples undergoes
when illuminated by the light source in question, as compared with those same testcolour samples when illuminated by a reference illuminate of comparable colour
temperature” (The Lighting Handbook, IES, 10th ed., 6.13).
Light Source
Fluorescent
60 – 90
LED
6
CRI
70 – 90
7. Temperature Ratings
Dialight
Temperature Ratings
Heat producing equipment is marked with a Temperature Code to indicate the
maximum surface temperature
Fluorescent LED
Ratings given at 40° C ambient temperature
Light Source
Fluorescent
T4
LED
7
T Rating
T5
8. Mercury Content
MASTER TL-D Super 80
14W/865 1SL
Mercury Content: 5 mg
Dialight
LED
Mercury Content: 0 mg
Disposal
The Resource Conservation and Recovery Act (RCRA) and the Universal Waste Rule
(UWR) regulate the disposal of lamps containing mercury. LEDs themselves contain
no mercury or harmful materials, which require special handling or unique recycling.
Light Source
Fluorescent
Avg. = 1.7mg – 15mg
Older lamps may contain 50mg+
LED
8
Mercury Content
0mg
9. Instant On/Off
Dialight
Fluorescent Ballast Options: Preheat, Rapid Start, Programmed Start and Instant Start
GE T8 Watt Miser: “Lamp warm-up time (i.e. when the lumen output reaches 90%
of its maximum) is on average 2 minutes.”
Light Source
Fluorescent
Instant – Couple of minutes
LED
9
Warm Up Time
Instant
11. Operating Temperatures
Relative luminous flux for fluorescent
in extreme temperatures
Dialight
Relative luminous flux for LEDs in
extreme temperatures
Light Source
Fluorescent
-29°C to 60°C
LED
11
Operating Temperature (°C)
-55°C to 65°C